Está en la página 1de 216

TCM Identification Code

CIVIL DESIGN CALCULATION REPORTS


MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 1 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

CIVIL DESIGN CALCULATION REPORTS


MEMORIA DE CÁLCULO - CIMENTACIONES DE HORMIGÓN

filename: C010-YA-CS-004001-03 MEMORIA DE CÁLCULO - CIMENTACIONES DE HOR

LYNKA
03 15/Feb/2023 Third issue M. Zagaria I. Colladon
F.J. Luque
LYNKA
02 30/Ene/2023 Second issue M. Zagaria I. Colladon
F.J. Luque
LYNKA
01 31/Oct/2022 First issue M. Zagaria I. Colladon
F.J. Luque
MOD-A4-E_Is.00

Rev Date Description Prepared Checked Approved

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 2 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

ÍNDICE

1 PROPÓSITO DEL DOCUMENTO................................................................................................. 5


1.1 OBJETO ................................................................................................................................. 5
1.2 ALCANCE .............................................................................................................................. 5
2 UBICACIÓN .................................................................................................................................. 6
3 NORMATIVA APLICABLE Y DOCUMENTOS DE REFERENCIA............................................... 7
3.1 NORMATIVA APLICABLE ...................................................................................................... 7
3.2 DOCUMENTOS DE REFERENCIA ........................................................................................ 8
4 GLOSARIO DE TÉRMINOS Y UNIDADES .................................................................................. 8
5 DESCRIPCIÓN DEL PROYECTO ................................................................................................ 9
6 DEFINICIÓN DEL CASO DE ESTUDIO ..................................................................................... 10
7 DEFINICIÓN DE LOS MATERIALES ......................................................................................... 12
7.1 HORMIGÓN ......................................................................................................................... 12
7.2 ACERO PARA BARRAS DE REFUERZO ............................................................................ 12
8 INFORME GEOTÉCNICO ........................................................................................................... 13
8.1 IDENTIFICACIÓN DEL INFORME GEOTÉCNICO .............................................................. 13
8.2 PARÁMETROS GEOTÉCNICOS DEL TERRENO ............................................................... 13
8.3 DURABILIDAD. AGRESIVIDAD DEL TERRENO ................................................................. 18
8.4 CARACTERIZACIÓN SÍSMICA DEL TERRENO ................................................................. 19
9 CÁLCULO DE LA CIMENTACIÓN DE LOS CENTROS DE TRANSFORMACIÓN .................. 20
9.1 CIMENTACIÓN ADOPTADA ................................................................................................ 20
9.2 ACCIONES CONSIDERADAS PARA EL CÁLCULO ........................................................... 20
10 CÁLCULO DE LA CIMENTACIÓN DEL CONTROL ROOM .................................................. 26
10.1 CIMENTACIÓN ADOPTADA ................................................................................................ 26
10.2 ACCIONES CONSIDERADAS PARA EL CÁLCULO ........................................................... 26
11 SOFTWARE DE CÁLCULO .................................................................................................... 28
12 ANEJO DE CÁLCULO CENTRO DE TRANSFORMACIÓN HUAWEI JUPITER-6000K-H1 . 29
12.1 NORMAS CONSIDERADAS ................................................................................................ 29
12.2 ACCIONES CONSIDERADAS ............................................................................................. 30
12.3 ESTADOS LÍMITE ................................................................................................................ 32
12.4 SITUACIONES DE PROYECTO .......................................................................................... 32
12.5 DATOS GEOMÉTRICOS DE GRUPOS Y PLANTAS ........................................................... 40
12.6 DATOS GEOMÉTRICOS DE PILARES ............................................................................... 40
12.7 DIMENSIONES, COEFICIENTES DE EMPOTRAMIENTO Y COEFICIENTES DE PANDEO
PARA CADA PLANTA ..................................................................................................................... 40
12.8 LOSAS Y ELEMENTOS DE CIMENTACIÓN ....................................................................... 40
MOD-A4-E_Is.00

12.9 MATERIALES UTILIZADOS ................................................................................................. 41


12.10 JUSTIFICACIÓN DE LA ACCIÓN SÍSMICA ..................................................................... 41
12.11 LOSA DE CIMENTACIÓN ................................................................................................ 47
12.12 TENSIONES SOBRE EL TERRENO ................................................................................ 66

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 3 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.13 ESFUERZO Y ARMADO DE PILARES ............................................................................. 67


12.14 VIGAS DE ATADO EN CABEZA DE PILARES ................................................................. 77
13 ANEJO DE CÁLCULO CONTROL ROOM ............................................................................. 87
13.1 NORMAS CONSIDERADAS ................................................................................................ 87
13.2 ACCIONES CONSIDERADAS ............................................................................................. 87
13.3 ESTADOS LÍMITE ................................................................................................................ 88
13.4 SITUACIONES DE PROYECTO .......................................................................................... 89
13.5 LOSAS Y ELEMENTOS DE CIMENTACIÓN ....................................................................... 93
13.6 MATERIALES UTILIZADOS ................................................................................................. 94
13.7 LOSA DE CIMENTACIÓN .................................................................................................... 94
13.8 TENSIONES SOBRE EL TERRENO .................................................................................. 106
14 ESFUERZO HIDROSTÁTICO NAPA FREÁTICA ................................................................. 107
15 MANUAL CENTROS DE TRANSFORMACIÓN ................................................................... 109
16 COMPUTATIONAL ANALYSIS REPORT OF 20FT S CONTAINER ................................... 156
17 COMPROBACIÓN PERNOS DE ANCLAJE CENTRO DE TRANSFORMACIÓN ............... 209
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 4 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

INDICE DE TABLAS

Tabla 1. Características del proyecto ..............................................................................................................5


Tabla 2. Coordenadas UTM .............................................................................................................................6
Tabla 3. Definiciones y abreviaturas ...............................................................................................................8
Tabla 4. Características principales .................................................................................................................9
Tabla 5. Características subcampo que compone la planta ...........................................................................9
Tabla 6. Configuración PFV .......................................................................................................................... 10
Tabla 7. Denominación de los materiales .................................................................................................... 12
Tabla 8. Identificación del estudio geotécnico ............................................................................................. 13
Tabla 9. Modelo estratigráfico del terreno .................................................................................................. 14
Tabla 10. Caracterización geotécnica del suelo de fundación ..................................................................... 15
Tabla 11. Capacidad de soporte para estructuras livianas, fundadas sobre relleno compactado de 0,50 [m]
de espesor, apoyado sobre el horizonte H-3 del modelo estratigráfico .............................................................. 16
Tabla 12. Capacidad de soporte para estructuras menores, fundadas sobre el horizonte H-2 del modelo
estratigráfico ........................................................................................................................................................ 16
Tabla 13. Grado de exposición del terreno debido a la presencia de sulfatos ............................................ 18
Tabla 14. Requisitos del cemento para el hormigón en contacto con sulfatos............................................ 19
Tabla 15. Requisitos del hormigón en contacto con sulfatos ....................................................................... 19
Tabla 16. Zona sísmica y valor de aceleración ............................................................................................. 20
Tabla 17. Parámetros sísmicos del terreno .................................................................................................. 20

INDICE DE IMÁGENES

Imagen 1 Ubicación PFV La Quinta. ................................................................................................................6


Imagen 2 Ubicación PFV La Quinta .................................................................................................................7
Imagen 3 Distribución equipos Centro de Transformación HUAWEI JUPITER-3000K-H1 ............................ 10
Imagen 4 Distribución equipos Centro de Transformación HUAWEI JUPITER-6000K-H1 ............................ 11
Imagen 5 Distribución Control Room ........................................................................................................... 11
Imagen 6 Esquema 3D de los equipos del Centro de Transformación HUAWEI JUPITER-3000K-H1 ........... 21
Imagen 7 Esquema 3D de los equipos del Centro de Transformación HUAWEI JUPITER-3000K-H1 ........... 21
Imagen 8 Cargas muertas aplicadas en los puntos de anclaje CT ................................................................ 22
Imagen 9 Sobrecarga de uso aplicadas en los puntos de anclaje CT ........................................................... 23
Imagen 10 Cargas de viento aplicadas en los puntos de anclaje de los pilares de los CTs .......................... 24
Imagen 11 Sobrecarga de nieve aplicadas en los puntos de anclaje CT ...................................................... 25
Imagen 12 Esquema Control Room ............................................................................................................. 26
Imagen 13 Cargas muertas aplicadas al Control Room ................................................................................ 27
Imagen 14 Cargas de viento aplicadas en los extremos de la caseta del Control Room ............................. 28
Imagen 15 3D Armado de cimentación, pilares y vigas de atado CT ........................................................... 29
Imagen 16 Esquema de malla y coordenadas en el programa cálculo Cypecad ......................................... 48
MOD-A4-E_Is.00

Imagen 17 3D Armado de losa de cimentación Control Room .................................................................... 87


Imagen 18 Esquema de malla y coordenadas en el programa cálculo Cypecad ......................................... 95

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 5 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

1 PROPÓSITO DEL DOCUMENTO

La planta fotovoltaica La Quinta está situada en la comuna de Cabrero, provincia de Bío Bío, región
de Bío Bío, Chile. Tendrá una potencia pico de 11,05 MWp, ocupará un área aproximada de 20,61 Ha.
A continuación, se muestra una tabla con los datos de proyecto más relevantes que deben ser tenidos
en cuenta:

CARACTERÍSTICAS DE PROYECTO
Potencia Pico 11,05 MWp
Potencia CA 9 MW
Ubicación Cabrero, Bio Bío (Chile)
Longitud -72.372733°
Latitud -37.062102°
X: 733596.23 E
Y: 5895009.33 S
Coordenadas X,Y
Datum WGS 84
Huso 18H
Área total (dentro del cerco) 20,61 Ha
Altura sobre el nivel del mar 137 m.s.n.m.

Tabla 1. Características del proyecto

1.1 OBJETO
El objeto de este documento es modelar, calcular, analizar y definir la cimentación de los Centros de
transformación (CTs) y Control Room a ejecutar en la planta fotovoltaica La Quinta ubicada en la
comuna de Cabrero, provincia de Bío Bío, región de Bío Bío, Chile.
Los resultados obtenidos quedan reflejados en los planos correspondientes, con dimensiones,
armados, despieces y detalles constructivos necesarios para la correcta ejecución de la estructura.
Además, se indican las características de los materiales empleados, acciones, coeficientes de
seguridad, hipótesis utilizadas en el cálculo, durabilidad, etc.

1.2 ALCANCE
El alcance de este documento comprende el análisis de la documentación suministrada por distintos
proveedores (fabricante del CT, oficina técnica de realización del estudio geotécnico, etc.); el análisis
y aplicación de la normativa correspondiente; el análisis de las cargas aplicables; el diseño y modelado
de la cimentación más adecuada desde el punto de vista técnico-económico; el cálculo de la
cimentación modelada; el análisis de los resultados; la completa definición de la cimentación
MOD-A4-E_Is.00

determinada, mediante planos, detalles constructivos y toda la información necesaria para ello.

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 6 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

2 UBICACIÓN

El Proyecto se encuentra ubicado a unos 3,49 km al sureste del centro de la ciudad de Cabrero por
ruta Panamericana Sur, perteneciente a la comuna del mismo nombre, en la Región del Bio Bío, Chile.
La ubicación del sitio se presenta en las siguientes imágenes.

CUADRO DE COORDENADAS UTM


SUR ESTE
UTM 5895009.33 733596.23

Tabla 2. Coordenadas UTM

Ubicación proyecto

Imagen 1 Ubicación PFV La Quinta.


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 7 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Parque Solar
Fotovoltaico La Quinta

Imagen 2 Ubicación PFV La Quinta

3 NORMATIVA APLICABLE Y DOCUMENTOS DE REFERENCIA

3.1 NORMATIVA APLICABLE


El diseño de la planta fotovoltaica La Quinta debe cumplir con todas las normativas locales, nacionales
e internacionales que sean de aplicación. Cumpliendo con el criterio más estricto de ellas.
- NCh170:2016 Hormigón-Requisitos generales.
- NCh430:2008 Hormigón armado - Requisitos de diseño y cálculo.
- NCh431:2010 Diseño Estructural - Cargas de Nieve.
- NCh432:2010 Diseño estructural - Cargas de viento.
- NCh433:2012 Diseño sísmico de edificios.
- NCh1537:2009 Diseño estructural - Cargas permanentes y cargas de uso.
- NCh2369:2003 Diseño sísmico de estructuras e instalaciones industriales.
- NCh3171:2017 Diseño estructural - Disposiciones generales y combinaciones de
cargas.
- ACI318 – 19 Requisitos de Reglamento para Concreto EstructuralASTM F281 – 10:
Standard Practice for testing forced entry, ballistic and low impact resistance of security fence
system.
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 8 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

3.2 DOCUMENTOS DE REFERENCIA


A continuación, se listas los principales documentos de referencia utilizados para el diseño de la planta
fotovoltaica La Quinta.
- C010-YX-DA-000001 Plano General Planta Fotovoltaica.
- C010-YA-DC-004001 Cimientos de Hormigón - Detalles y Armaduras.
- Layout Drawing for JUPITER-3000K-H1-Preliminary.dwg
- Layout Drawing for JUPITER-6000K-H1-Preliminary.dwg
- C010-YG-RS-002001-01 Informe de Mecánica de Suelos, “Proyecto Parque Solar Fotovoltaico
LA QUINTA”, Comuna de Cabrero, Región de Bío Bío, chile.
- C010-YG-RS-002002-01 Informe de Mecánica de Suelos, Ensayos Geotécnicos Adicionales,
“Proyecto Parque Solar Fotovoltaico LA QUINTA”, Comuna de Cabrero, Región de Bío Bío,
chile.

4 GLOSARIO DE TÉRMINOS Y UNIDADES

Cabe destacar que todas las unidades de medidas utilizadas en el informe están basadas en el
Sistema Internacional de medidas (SI). Las abreviaturas empleadas en el desarrollo de la memoria se
recogen en la siguiente tabla:

PFV Parque fotovoltaico


kVA, MVA Kilovoltio amperio, megavoltio amperio
Ha Hectáreas
V, kV Voltios, kilovoltios
m.s.n.m Metros sobre el nivel del mar
mm, m, km Milímetros, metros, kilómetros
Wp, kWp, MWp Vatios pico, kilovatios pico, megavatios pico
CC Corriente continua
CA Corriente alterna
PV Fotovoltaico
A] Amperios
ºC] Grados centígrados
2
mm Milímetros cuadrados
Hz Hercios
BT Baja tensión
MT Media tensión
m/s Metros por segundo
kWh Kilovatio hora
kg Kilogramos
MOD-A4-E_Is.00

Tabla 3. Definiciones y abreviaturas

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 9 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

5 DESCRIPCIÓN DEL PROYECTO

La Planta Fotovoltaica contará con un área total de instalación de 20,61 Ha. El parque solar albergará
un total de 17.024 módulos con una potencia de 645/650/655 Wp por módulo y una capacidad total
de 11.050 kWp.
A continuación, se recogen las principales características de la instalación:

Planta fotovoltaica La Quinta


Potencia nominal (CA) 9 MW
Potencia pico (CC) 11,05 MWp
Ratio CA/CC 1,23
Sistema 1.500 V
Inversor HUAWEI SUN2000-330KTL-H1
Módulos TRINA SOLAR TSM-DEG 21C.20 645/650/655
Strings 532
241 x Trinatracker Vanguard 1x64
Estructura
50 x Trinatracker Vanguard 1x32
Pitch 6m
Tabla 4. Características principales

El parque fotovoltaico cuenta con un centro de transformación. En la siguiente tabla, se adjuntan los
principales parámetros:

Características
Centros transformadores Unidades Valor
principales
Potencia CC MWp 3,82
Potencia CA MVA 3,11
CU.01
Número de módulos Ud. 5.888
Número de string inverter Ud. 10
Potencia CC MWp 7,23
Potencia CA MVA 5,88
CU.02
Número de módulos Ud. 11.136
Número de string inverter Ud. 19
Tabla 5. Características subcampo que compone la planta
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 10 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

La configuración de cada campo fotovoltaico se recoge en la siguiente tabla:

CU Nº Strings por S.I Nº String SI Nº Módulos Potencia MWp

19 76 4 2432
CU.01 3,82
18 108 6 3456

CU Nº Strings por S.I Nº String SI Nº Módulos Potencia MWp

19 114 6 3648
CU.02 7,23
18 234 13 7488
Tabla 6. Configuración PFV

6 DEFINICIÓN DEL CASO DE ESTUDIO

El elemento de cimentación a diseñar deberá ser adecuado para el equipo que se va a asentar sobre
él, seleccionando la mejor solución de compromiso considerando criterios técnicos, económicos y de
ejecución.
Los Centros de Transformación para instalar, del fabricante Huawei, son el modelo JUPITER-3000K-
H1 que se muestra en la Imagen 3 y el modelo JUPITER-6000K-H1 que se muestra en la Imagen 4,
además de la caseta del Control Room en la Imagen 5. Estos CTs comprenden los equipos de
inversión, protecciones y transformación de la planta fotovoltaica.
MOD-A4-E_Is.00

Imagen 3 Distribución equipos Centro de Transformación HUAWEI JUPITER-3000K-H1

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 11 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Imagen 4 Distribución equipos Centro de Transformación HUAWEI JUPITER-6000K-H1

Imagen 5 Distribución Control Room

El CT puede considerarse como un elemento compacto único al estar todos los equipos dentro de la
misma envolvente del container.
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 12 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

7 DEFINICIÓN DE LOS MATERIALES

En la Tabla 7 se recoge la denominación completa de cada uno de los materiales a utilizar para los
elementos de cimentación.

Material Aplicación Denominación


Hormigón Hormigón estructural H25 (10) / 20-6
Acero Acero para barras de refuerzo A-630-420H
Tabla 7. Denominación de los materiales

7.1 HORMIGÓN
El hormigón estructural utilizado para los elementos de cimentación es el H25 cuya resistencia
específica a compresión debe ser, según NCh170: fc'=25 MPa. Para este caso, se ha considerado
una fracción defectuosa del 10%, un tamaño máximo nominal del árido de 20 mm para la losa de
cimentación y de 15 mm para los pilares y vigas de atado de pilares y un grado de asentamiento de
cono igual a 6.
El recubrimiento libre mínimo para hormigón vaciado en obra (no pretensado) colocado contra el suelo
y permanentemente expuesto a él y en condiciones ambientales normales debe ser, según la norma
NCh430, sección 7.7, 50 mm.

7.2 ACERO PARA BARRAS DE REFUERZO


Para este proyecto se utilizará acero para las barras de refuerzo o armaduras de calidad A-630-420H,
según la norma NCh204, de distintos diámetros según los requisitos específicos de cada elemento de
cimentación y estructura.
Los empalmes o traslapos de las barras de armadura deberán realizarse según las disposiciones de
la norma ASCI 318SR-14, siempre con un mínimo de 300 mm (acero corrugado).
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 13 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

8 INFORME GEOTÉCNICO

8.1 IDENTIFICACIÓN DEL INFORME GEOTÉCNICO


La identificación del informe geotécnico se detalla en la Tabla 8.

Empresa GDE Consultores Geotécnicos


Referencia del informe C010-YG-RS-002001
Fecha de realización 01/09/2022
Marcelo Paredes.
Autores M. Zagaria.
B. Marcucci.

Empresa GDE Consultores Geotécnicos


Referencia del informe C010-YG-RS-002002
Fecha de realización 12/01/2023
Marcelo Paredes.
Rogerto Olguín.
Autores
M. Zagaria.
B. Marcucci.
Tabla 8. Identificación del estudio geotécnico

8.2 PARÁMETROS GEOTÉCNICOS DEL TERRENO


En términos generales, el terreno se presenta bastante homogéneo en profundidad a lo largo de todo
el sitio prospectado. Por lo tanto, a partir de lo observado en las calicatas realizadas, es posible definir
el siguiente modelo estratigráfico para el sector en estudio:

Horizonte Cotas Limites [m] Espesor [m] Descripción Estratigráfica


Capa vegetal conformada de arena arcillo
limosa, café a café oscuro, humedad media,
compacidad baja, plasticidad baja,
H-1 0,00 - 0,20 a 0,40 0,20 a 0,40 estructura de migajón (porosa).

En este horizonte es posible encontrar


raicillas abundantes y raíces ocasionales.
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 14 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Horizonte Cotas Limites [m] Espesor [m] Descripción Estratigráfica


Arena limosa, color café grisáceo oscuro,
humedad media a alta, compacidad baja a
media, plasticidad baja a nula, estructura
homogénea.

En este horizonte es posible encontrar


H-2 0,20 a 0,40 - 0,80 a 1,20 0,50 a 0,90
raicillas de forma aislada.

Particularmente, en las calicatas C-02 y C-


09 se encontró que este horizonte llegó a
0,30 a 1,40 [m] y 0,30 a 1,60 [m] de
profundidad respectivamente.
Arena con bajo a nulo contenido de finos,
color gris oscuro, humedad alta,
compacidad media a baja, plasticidad nula,
estructura homogénea.

Particularmente, en las calicatas C-01 y C-


H-3 0,80 a 1,20 – 2,00 a 2,50 0,60 a 1,70 10 se encontraron lentes de arena algo
limosa con granos oxidados, de color gris
anaranjado oscuro entre los 1,10 a 1,15 [m]
y 0,90 a 1,10 [m] de profundidad
respectivamente, de compacidad media a
baja, plasticidad nula y estructura
homogénea.
Nota: Se detectó napa freática en todas las calicatas ejecutadas, generalmente en superficie, entre
0,00 a 0,40 metros de profundidad medidos desde nivel de terreno a la fecha de las prospecciones
(19 y 20 de julio de 2022).
Tabla 9. Modelo estratigráfico del terreno

A partir de los análisis de los resultados de laboratorio y de terreno efectuados, se definen los
siguientes parámetros geotécnicos de los suelos representativos del sector.

Relleno
Parámetro H-2 H-3 estructural
compactado (**)

Arenas con bajo


Arenas limosas
a nulo contenido de
Tipo de suelo color café grisáceo -
finos color gris
oscuro.
oscuro.
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 15 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Relleno
Parámetro H-2 H-3 estructural
compactado (**)

Profundidad a la que En promedio, En promedio,


aparece el suelo de variable entre 0,20 a variable entre 0,80 y -
fundación, [m] (*) 0,40 1,20

Densidad natural [t/m3] 1,96 1,97 2,10


Humedad [%] 28,3 27,8 12,0
Ángulo de fricción interna, ϕ
32 34 34
[°]
Cohesión, c [t/m2] 0,00 0,00 0,00
Resistencia al corte no
3,5 3,5 -
drenada, SU [t/m2]
Coeficiente de Poisson, ʋ 0,33 0,33 0,35
Módulo de deformación
900 1.000 3.000
estático, E [t/m2]
Módulo de deformación
2.700 3.000 9.000
dinámico, Ed [t/m2]
(*): Medida desde el nivel de terreno actual.
(**): Compuesto por arena del H-3, compactada.
Tabla 10. Caracterización geotécnica del suelo de fundación
Los parámetros de cálculo considerados para la cimentación de los Centros de Transformación y del
Control Room son los siguientes:
Centros de Transformación

- Tensión admisible del terreno H-3 ………………………………….. 0,75 kg/cm2≈0,075 MPa


- Módulo de balasto de la losa H-3 …………………………..……..… 3.548,1 kN/m3

Se recomienda que el sello de fundación de las estructuras a proyectar quede sobre un relleno
estructural compactado de espesor mínimo 0,50 [m], apoyado sobre la arena con bajo a nulo contenido
de finos, color gris oscuro correspondiente al horizonte H-3 del modelo estratigráfico. Además, se
recomienda que el sello de fundación para el apoyo del relleno estructural se localice a una
profundidad de 0,60 [m] como mínimo medido desde el nivel de terreno actual, traspasando
íntegramente el horizonte H-1 y el H-2 del modelo estratigráfico, por lo que la profundidad del sello de
excavación será como mínimo de 1,10 metros medida desde nivel de terreno natural.
El sello de fundación deberá estar libre de material suelto y/o deleznable, o de otro tipo de suelo
distinto al definido.
MOD-A4-E_Is.00

Los análisis fueron realizados para el caso más desfavorable (utilizando la resistencia no drenada de
la arena del H-3), y considerando un relleno estructural estabilizado de 0,50 [m] de espesor bajo
fundación, el que se apoya sobre el horizonte H-3 del modelo estratigráfico.

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 16 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Capacidad de soporte estática Capacidad de soporte sísmica


Ancho de fundación B admisible [kg/cm2] admisible [kg/cm2]
[m]
Cuadrada Rectangular Cuadrada Rectangular

De 0,40 hasta 0,70 1,80 1,20 2,40 1,60

Mayor 0,70 hasta 1,00 1,40 1,00 1,86 1,33

Mayor a 1,00 hasta 2,00 1,00 0,85 1,33 1,13

Mayor a 2,00 hasta 3,00 0,85 0,75 1,13 0,99

Nota: La capacidad de soporte sísmica se ha considerado 1,33 veces la estática, según las
recomendaciones del International Building Code, International Code Council, Washington, DC, 2006.
Tabla 11. Capacidad de soporte para estructuras livianas, fundadas sobre relleno compactado de 0,50 [m] de
espesor, apoyado sobre el horizonte H-3 del modelo estratigráfico

Control Room
- Tensión admisible del terreno H-2 ………………………………….. 0,67 kg/cm2≈0,067 MPa
- Módulo de balasto de la losa H-2 …………………………..……..… 4.078,6 kN/m3

El sello de fundación estará en el horizonte H-2 del modelo estratigráfico, con un sello de fundación
no menor a 0,50[m] medido desde el nivel de terreno actual. El sello de excavación deberá
compactarse al menos hasta el 95% de la densidad seca del ensayo Proctor modificado, o bien, a una
densidad relativa del 80%.
La recepción de los sellos de excavación y/o fundación deberá ser realizado por un ingeniero
geotécnico.

Capacidad de soporte estática Capacidad de soporte sísmica


Horizonte admisible [kg/cm2] admisible [kg/cm2]
Cuadrada Rectangular Cuadrada Rectangular
H-2
Arenas limosas color 0,67 0,89
café grisáceo oscuro
Nota: La capacidad de soporte sísmica se ha considerado 1,33 veces la estática, según las
MOD-A4-E_Is.00

recomendaciones del International Building Code, International Code Council, Washington, DC, 2006.
Tabla 12. Capacidad de soporte para estructuras menores, fundadas sobre el horizonte H-2 del modelo
estratigráfico

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 17 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Al estar la napa freática prácticamente superficial, se deberá contemplar un sistema de bombeo y


agotamiento de la napa para realizar la excavación.

Nota importante:
Para analizar la respuesta del terreno frente a un sismo de magnitud significativa, se recomienda
realizar ensayos de penetración estándar (SPT), lo que permitirá evaluar el potencial de
licuefacción en profundidad del subsuelo del sitio de emplazamiento de las estructuras proyectadas
(debido a la compacidad media a baja de las arenas y a la existencia de nivel freático encontrada en
superficie en las exploraciones realizadas). Con este análisis se podrán definir medidas para
mitigación de licuación de suelos, en caso de que exista este peligro geotécnico, lo que podría
modificar las especificaciones de fundaciones descritas en el informe de mecánica de suelos.

Según los resultados del informe “C010-YG-RS-002002-01 Informe Geotécnico-Ensayos adicionales”,


las principales conclusiones y recomendaciones son:
- A partir de los dos sondajes efectuados (S-1 en el sector norte del terreno y S-2 en el sector
sur), ambos de 10 metros de profundidad, y de los resultados de los ensayos de penetración
estándar SPT, se verifica que los primeros 3 a 4 metros del terreno están constituidos por una
arena suelta, con napa prácticamente superficial, corroborando lo detectado con las calicatas.

- En complemento con lo anterior, en el sondaje S-1 se encuentra un horizonte de arena densa


entre 4 y 7 metros, para nuevamente bajar el grado de compacidad entre los 8 y los 10 metros.
El sondaje S-2 muestra que las arenas se encuentran en estado suelto prácticamente en todos
los horizontes hasta los 10 metros de profundidad, a excepción de un horizonte de arena densa
en torno a los 3 metros de profundidad.

- Del análisis de licuación efectuado, el resultado más relevante para el proyecto consiste en
que para ambos sondajes los primeros 3 metros son susceptibles a licuar. Esta condición se
da tanto para un sismo de magnitud 8,5 y PGA de 0,55 g, como para un sismo de magnitud
7,5 y PGA de 0,20 g.

- Asimismo, en el sondaje S-1 (sector norte del terreno), para un sismo de magnitud 8,5 y PGA
de 0,55 g existe un horizonte entre los 4 y los 7 metros que no licúa, y entre 8 y los 10 metros
nuevamente esos horizontes son potencialmente licuables, mientras que en el sondaje S-2
(sector sur del terreno) se aprecia que en la arena únicamente a los 3 metros existe un
horizonte no licuable. En todo el resto de las profundidades ensayadas, existe riesgo de
licuación.

- Realizando el análisis de licuación para un sismo de menor magnitud que el anteriormente


expuesto, esto es con una magnitud de 7,5 y un PGA de 0,20 g, se aprecia que nuevamente
los 3 metros superficiales son susceptibles a licuar, en ambos sondajes. Además, en el sondaje
S-1, desde los 4 hasta los 10 metros, las arenas no son potencialmente licuables, mientras
que en el sondaje S-2 nuevamente el único estrato no licuable se encuentra a los 3 metros de
profundidad.
MOD-A4-E_Is.00

- En vista de lo anterior, para mitigar la generación de deformaciones excesivas en las


instalaciones asociadas al parque fotovoltaico La Quinta ante la ocurrencia de un sismo de
gran magnitud, se recomienda implementar un mejoramiento del suelo en al menos los
primeros 3 metros bajo el sello de fundación de las estructuras, o hasta llegar al estrato de
This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 18 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

arena densa. Este mejoramiento podría consistir en realizar la excavación y retiro de la arena
existente bajo fundaciones, para luego volver a ser colocada, compactándola a un grado de
compacidad igual o superior al 95 % del Proctor Modificado o a una densidad relativa igual o
superior al 80 %. Una de las complejidades a resolver en esta propuesta de mejoramiento de
suelos, consiste en el desarrollo de un sistema de agotamiento de napa tal que permita realizar
las excavaciones y las faenas de compactación hasta la profundidad requerida (3 a 4 metros
desde nivel de terreno actual), considerando que la napa se encuentra prácticamente
superficial.

- Otras alternativas para aumentar la compactación de los primeros 3 a 4 metros consisten en


técnicas como la compactación dinámica o columnas de grava (cuyas especificaciones
requieren de un diseño particular realizado por empresas especialistas en estos tipos de
mejoramiento de suelos), aunque este tipo de soluciones comúnmente se han utilizado en
obras tales como construcción de edificios, terraplenes o parques eólicos, por lo que es posible
que para parques solares de la magnitud de La Quinta, los costos asociados a estos
mejoramientos no sean compatibles con el presupuesto involucrado. De todas formas, esta
decisión corresponde al inversionista, según las evaluaciones propias que pueda efectuar.

- Las capacidades de soporte indicadas en el informe C010-YG-RS-002001-01 son válidas


únicamente para una condición estática, donde el suelo responda de manera drenada. En caso
de sismos, o de una carga rápida tal que genere aumento en las presiones de poros, existe
una alta probabilidad de ocurrencia de deformaciones inadmisibles para las estructuras si es
que no se materializa un mejoramiento de suelos.

CONCLUSIÓN:
Las cimentaciones tanto de los Centros de Transformación, como del Control Room, se realizarán
sobre una capa de material triturado y compactado, y bajo esta una capa de Bolders Ciclópicos hasta
eliminar los primeros 3 metros de terreno actual como se indica en el anexo al informe geotécnico.
Se proyectará conforme al plano C010-YA-DC-004001 CIMIENTOS DE HORMIGÓN - DETALLES Y
ARMADURAS.

8.3 DURABILIDAD. AGRESIVIDAD DEL TERRENO


El estudio geotécnico del terreno determina un contenido máximo en sulfatos del 0,0043% por lo que
se tiene un grado de exposición S0 o No agresivo, según la clasificación de la normativa NCh170
Of.2016 que se muestra en la Tabla 13.
MOD-A4-E_Is.00

Tabla 13. Grado de exposición del terreno debido a la presencia de sulfatos

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 19 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Por lo tanto, en la Tabla 14 se establece los requisitos del cemento según el grado de exposición al
que está sometido el hormigón.

Tabla 14. Requisitos del cemento para el hormigón en contacto con sulfatos

Del mismo modo, para cada grado de exposición, el hormigón debe cumplir con el requisito de
resistencia mínima especificada y con uno de los siguientes requisitos: dosis mínima de cemento o
profundidad de penetración de agua, como se indica en la Tabla 15.

Tabla 15. Requisitos del hormigón en contacto con sulfatos

8.4 CARACTERIZACIÓN SÍSMICA DEL TERRENO


Considerando la ubicación del proyecto, en el municipio de Cabrero, comuna de Cabrero, región de
Bío Bío, Chile, se ha determinado la sismicidad en base a las normas aplicables, NCh433 y NCh2369.
La zonificación sísmica y sus parámetros de cálculo básico se muestran en la siguiente tabla:
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 20 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Valor de la aceleración efectiva


Zona Sísmica
máxima A0
3 0,40 g
Tabla 16. Zona sísmica y valor de aceleración

Una vez identificado el tipo de terreno en la planta fotovoltaica podremos definir los siguientes
parámetros, facilitados en NCh433 de acuerdo a la tabla Nº 6.3 de la referida Norma y en la NCh2369
de acuerdo a la tabla Nº 5.4 el periodo predominante de vibración es igual al indicado en la Tabla17.

Tipo de suelo Horizonte S T0 (s) T’ (s) n p


IV H-3 1,30 1,20 1,35 1,80 1,0
Tabla 17. Parámetros sísmicos del terreno

9 CÁLCULO DE LA CIMENTACIÓN DE LOS CENTROS DE TRANSFORMACIÓN

9.1 CIMENTACIÓN ADOPTADA


A la vista de los resultados obtenidos, el terreno existente en la parcela, el proyecto previsto y en base
a un balance razonado entre la seguridad y la economía se aconseja cimentar mediante losa de
cimentación, pilares enanos de hormigón armado y vigas de atado en cabeza de pilares, empotrando
la losa de cimentación en el sello de fundación del horizonte H-3 y mejora de terreno según
indicaciones del informe geotécnico.
Las dimensiones y armado de la losa de cimentación, pilares y vigas de atado de los pilares quedan
reflejados en el plano C010-YA-DC-004001 CIMIENTOS DE HORMIGÓN - DETALLES Y
ARMADURAS, también en dicho plano queda reflejado la elevación del centro de transformación con
respecto al terreno para evitar la entrada de agua al mismo.

9.2 ACCIONES CONSIDERADAS PARA EL CÁLCULO


Las acciones consideradas para el cálculo de la cimentación de cada CT se basan en la normativa
aplicable.
9.2.1 ACCIONES PERMANENTES
9.2.1.1 PESO PROPIO
- Densidad de hormigón armado....................................................... 25,00 kN/m3
- Densidad de hormigón en masa…………....................................... 23,00 kN/m3

9.2.1.2 CARGAS MUERTAS


- Peso propio CT HUAWEI JUPITER-3000K-H1…......……………….150,00 KN
MOD-A4-E_Is.00

- Peso propio CT HUAWEI JUPITER-6000K-H1…......……………….220,00 kN


- Peso propio volumen de aceite del Transformador…...……………. 34,00 KN

El peso de los equipos se ha obtenido del Manual, incluido en el apartado 15 de la presente memoria.
This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 21 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Imagen 6 Esquema 3D de los equipos del Centro de Transformación HUAWEI JUPITER-3000K-H1


MOD-A4-E_Is.00

Imagen 7 Esquema 3D de los equipos del Centro de Transformación HUAWEI JUPITER-3000K-H1

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 22 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Las cargas muertas están aplicadas en los puntos de anclaje sobre los pilares o vigas de atado, como
cargas puntuales.

Peso CT Carga Carga


Ancho CT Largo CT Área CT
JUPITER-3000K-H1 Puntual CM1 Puntual CM2
[m] [m] [m2]
[kN] [kN] [kN]

184 2,438 6,058 14,769 23,008 46,000

Peso CT Carga Carga


Ancho CT Largo CT Área CT
JUPITER-6000K-H1 Puntual CM1 Puntual CM2
[m] [m] [m2]
[kN] [kN] [kN]

254 2,438 6,058 14,769 31,760 63,500

Imagen 8 Cargas muertas aplicadas en los puntos de anclaje CT

9.2.2 ACCIONES VARIABLES


9.2.2.1 SOBRECARGA DE USO
La sobrecarga de uso sobre la cimentación se ha determinado en base a la norma NCh1537.Of2009,
siendo:

𝑘𝑔 𝑘𝑁
𝑆𝑈 2 𝑘𝑃𝑎 200 2
𝑚 𝑚
MOD-A4-E_Is.00

La sobrecarga de uso está aplicada en los puntos de anclaje sobre los pilares o vigas de atado, como
cargas puntuales.

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 23 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Carga Carga
Uso CT Ancho CT Largo CT Área CT Puntual Puntual
[kN/m2] [m] [m] [m2] QM1 QM2
[kN] [kN]
2 2,438 6,058 14,769 3,694 7,385

Imagen 9 Sobrecarga de uso aplicadas en los puntos de anclaje CT

9.2.2.2 VIENTO
Las cargas de viento actuantes sobre los equipos dispuestos en la cimentación se han determinado
en base a la norma NCh432, resultando una velocidad básica del viento para la ubicación del proyecto
de:

𝑣 45 𝑚/𝑠

Se han considerado dos hipótesis de carga viento, actuando en direcciones perpendiculares entre sí
y en los dos sentidos.
Las cargas de viento están aplicadas en los puntos de anclaje de los pilares, como cargas puntuales
al multiplicar la carga de viento por la superficie de actuación de esta.

Ancho tributario Área [m2] Carga de viento [kN]


Altura [m] Zona BT Zona BT V(0º) V(90º) V(180º) V(270º)
X1 X2 X3 Y1 X1 X2 X3 Y1 F1 F2 F2 F4 F6 F5 F6 F1 F3 F5
3,096 1,514 3,029 1,515 1,219 4,687 9,378 4,690 3,774 4,04 4,04 5,02 10,05 5,03 4,04 4,04 5,02 10,05 5,03
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 24 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Imagen 10 Cargas de viento aplicadas en los puntos de anclaje de los pilares de los CTs

9.2.2.3 NIEVE
La carga de nieve se ha determinado en base a la norma NCh431.Of2010, obteniéndose una carga
de nieve básica para una altitud sobre el nivel del mar de 137 m. de:

𝑝 0,25 𝑘𝑁/𝑚

La sobrecarga de nieve está aplicada en los puntos de anclaje sobre los pilares o vigas de atado,
como cargas puntuales.

Carga Carga
Nieve CT Ancho CT Largo CT Área CT
Puntual N1 Puntual N2
[kN/m2] [m] [m] [m2]
[kN] [kN]

0,25 2,438 6,058 14,769 0,462 0,923


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 25 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Imagen 11 Sobrecarga de nieve aplicadas en los puntos de anclaje CT

9.2.3 ACCIONES ACCIDENTALES. SISMO


Las acciones sísmicas de la ubicación de proyecto se han determinado en base a la norma NCh2369,
resultando:
𝑚
𝑍𝑜𝑛𝑎 𝑠í𝑠𝑚𝑖𝑐𝑎 3 → 𝐴 3,92 0,40𝑔
𝑠
De los distintos métodos de cálculo que permiten analizar el comportamiento sísmico de las
estructuras, el procedimiento habitual es considerar métodos lineales, a determinar en función de las
características específicas del caso de estudio. En este caso, debido a que la estructura que se analiza
tiene una altura inferior a 20 metros, se realizará un estudio sísmico basado en el análisis estático o
de fuerzas equivalentes (NCh2369, sección 5.2.2.a).
El análisis sísmico deberá considerar, al menos, dos direcciones horizontales aproximadamente
perpendiculares entre sí (NCh2369, sección 5.1.1). Además, el efecto de las aceleraciones sísmicas
verticales se debe considerar siempre en determinados casos, como lo es el de fundaciones y
elementos de anclaje y apoyo de estructuras y equipos (caso c). Para este caso de estudio, la acción
sísmica vertical en forma estática se puede considerar con un coeficiente sísmico (NCh2369, sección
5.5.1.b):

2 𝐴
𝐶
3 𝑔
Adicionalmente, se debe tener en cuenta el tipo de suelo donde se va a ejecutar el proyecto. En base
a los datos del geotécnico, el terreno del proyecto se clasifica como tipo C (NCh2369, Tabla 5.3). A
este suelo le corresponden unos parámetros particulares que se han de considerar en el cálculo de la
acción sísmica (NCh2369, Tabla 5.4), cuyos datos se reflejan en la Tabla 14 de la presente memoria.
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 26 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

10 CÁLCULO DE LA CIMENTACIÓN DEL CONTROL ROOM

10.1 CIMENTACIÓN ADOPTADA


A la vista de los resultados obtenidos, el terreno existente en la parcela, el proyecto previsto y en base
a un balance razonado entre la seguridad y la economía se aconseja cimentar mediante losa de
cimentación, empotrando la losa de cimentación en el sello de fundación del horizonte H-2.
El sello de fundación estará en el horizonte H-2 a una profundidad no menor de 0,50 m medido desde
el nivel de terreno actual, para empotrar en dicho horizonte se realizará un relleno estructural de 0,50
m según indicaciones del geotécnico.
Las dimensiones y armado de la losa de cimentación quedan reflejados en el plano C010-YA-DC-
004001 CIMIENTOS DE HORMIGÓN - DETALLES Y ARMADURAS, también en dicho plano queda
reflejado la elevación del centro de transformación 10 cm. con respecto al terreno para evitar la entrada
de agua al mismo.

10.2 ACCIONES CONSIDERADAS PARA EL CÁLCULO


Las acciones consideradas para el cálculo de la cimentación del Control Room se basan en la
normativa aplicable.

10.2.1 ACCIONES PERMANENTES


10.2.1.1 PESO PROPIO
- Densidad de hormigón armado....................................................... 25,00 kN/m3
- Densidad de hormigón en masa…………....................................... 23,00 kN/m3

10.2.1.2 CARGAS MUERTAS


- Peso propio caseta Control Room…......................…………………. 7,00 kN

Imagen 12 Esquema Control Room


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 27 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Las cargas muertas están aplicadas como una carga superficial.

Carga
Peso Caseta Ancho Largo Área
Superficial
Control Room [m] [m] [m2]
[kN/m2]
7 2 3 6,000 1,167
Imagen 13 Cargas muertas aplicadas al Control Room

10.2.2 ACCIONES VARIABLES


10.2.2.1 SOBRECARGA DE USO
La sobrecarga de uso sobre la cimentación se ha determinado en base a la norma NCh1537.Of2009,
y el mobiliario interno, siendo:

𝑘𝑔 𝑘𝑁
𝑆𝑈 4 𝑘𝑃𝑎 400 4
𝑚 𝑚

La sobrecarga de uso está aplicada como una carga superficial.

10.2.2.2 VIENTO
Las cargas de viento actuantes sobre los equipos dispuestos en la cimentación se han determinado
en base a la norma NCh432, resultando una velocidad básica del viento para la ubicación del proyecto
de:

𝑣 45 𝑚/𝑠

Se han considerado dos hipótesis de carga viento, actuando en direcciones perpendiculares entre sí
y en los dos sentidos.
Las cargas de viento están aplicadas en los puntos de anclaje de los pilares, como cargas puntuales
al multiplicar la carga de viento por la superficie de actuación de esta.

Ancho tributario Área [m2] Carga de viento [kN]


Altura [m] Zona BT Zona BT
V(0º) V(90º) V(180º) V(270º)
X1 Y1 X1 Y1
3,1 1,500 1,000 4,650 3,100 3,32 4,98 3,32 4,98
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 28 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Imagen 14 Cargas de viento aplicadas en los extremos de la caseta del Control Room

10.2.2.3 NIEVE
La carga de nieve se ha determinado en base a la norma NCh431.Of2010, obteniéndose una carga
de nieve básica para una altitud sobre el nivel del mar de 305 m. de:

𝑝 0,25 𝑘𝑁/𝑚

La sobrecarga de nieve está aplicada como una carga superficial.

11 SOFTWARE DE CÁLCULO

Las características de los programas utilizados son las siguientes:


- Título: CYPE
Versión: 2022.h
Nombre de la empresa: CYPE Ingenieros, S.A.
Avda. Eusebio Sempere, 5.
03003 ALICANTE – España
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 29 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12 ANEJO DE CÁLCULO CENTRO DE TRANSFORMACIÓN HUAWEI JUPITER-


6000K-H1

Dado que las cimentaciones que se proponen para los Centros de Transformación HUAWEI JUPITER-
3000K-H1 y JUPITER-6000K-H1 serán idénticas, se va a proceder a realizar el cálculo y comprobación
de la cimentación asociada al modelo JUPITER-6000K-H1 por ser el que cuenta con mayores cargas
asociadas, entendiéndose válida de igual forma para el modelo JUPITER-3000K-H1 al quedar del lado
de la seguridad.

Imagen 15 3D Armado de cimentación, pilares y vigas de atado CT

12.1 NORMAS CONSIDERADAS


Hormigón: NCh430.Of2008, Dº60:2011
Aceros conformados: NCh427
Aceros laminados y armados: NCh427
Categoría de uso: General
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 30 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.2 ACCIONES CONSIDERADAS

12.2.1 GRAVITATORIAS

S.C.U Cargas muertas


Planta
(kN/m²) (kN/m²)
Baja 2.0 0.0
Cimentación 0.0 0.0

12.2.2 VIENTO
Se ha tenido en cuenta la acción del viento mediante cargas aplicadas en las siguientes hipótesis: 'V
(0º)', 'V (90º)', 'V (180º)' y 'V (270º)'.

12.2.3 SISMO
Norma utilizada: NCh2369
Norma Chilena Oficial
Diseño Sísmico de Edificios
Diseño Sísmico de Estructuras e Instalaciones Industriales

Método de cálculo: Análisis Estático (NCh42369, SECCIÓN 5.2.2)

12.2.4 HIPÓTESIS DE CARGA

Automáticas Peso propio


Cargas muertas
Sobrecarga de uso
Sismo X 1
Sismo X 2
Sismo Y 1
Sismo Y 2
Adicionales Referencia Naturaleza
V (0º) Viento
V (90º) Viento
V (180º) Viento
V (270º) Viento
N1 Nieve
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 31 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.2.5 CARGAS HORIZONTALES Y EN CABEZA DE PILARES


12.2.5.1 CARGAS HORIZONTALES EN PILARES

Referencia pilar Dirección de la carga Tipo de carga Hipótesis Valor Cota (m)
F3 Y General Carga uniforme Cargas muertas -7.52 kN/m Desde: 0.00 Hasta: 1.35
F4 Y General Carga uniforme Cargas muertas 7.52 kN/m Desde: 0.00 Hasta: 1.35

12.2.5.2 CARGAS EN CABEZA DE PILARES

Referencia pilar Hipótesis N (kN) Mx (kNꞏm) My (kNꞏm) Qx (kN) Qy (kN) T (kNꞏm)


F1 V (0º) 0.00 0.00 0.00 4.04 0.00 0.00
V (270º) 0.00 0.00 0.00 0.00 -5.02 0.00
F2 V (0º) 0.00 0.00 0.00 4.04 0.00 0.00
V (90º) 0.00 0.00 0.00 0.00 -5.02 0.00
F3 Cargas muertas 63.50 0.00 0.00 0.00 0.00 0.00
Sobrecarga de uso 7.38 0.00 0.00 0.00 0.00 0.00
V (270º) 0.00 0.00 0.00 0.00 -10.05 0.00
N1 0.92 0.00 0.00 0.00 0.00 0.00
F4 Cargas muertas 63.50 0.00 0.00 0.00 0.00 0.00
Sobrecarga de uso 7.38 0.00 0.00 0.00 0.00 0.00
V (90º) 0.00 0.00 0.00 0.00 10.05 0.00
N1 0.92 0.00 0.00 0.00 0.00 0.00
F5 V (180º) 0.00 0.00 0.00 -4.04 0.00 0.00
V (270º) 0.00 0.00 0.00 0.00 -5.03 0.00
F6 V (90º) 0.00 0.00 0.00 0.00 5.03 0.00
V (180º) 0.00 0.00 0.00 -4.04 0.00 0.00

12.2.6 LISTADO DE CARGAS


Cargas especiales introducidas (en kN, kN/m y kN/m²)

Grupo Hipótesis Tipo Valor Coordenadas

Cimentación Cargas muertas Lineal 6.75 (1.89,0.15) (1.89,2.42)


Cargas muertas Lineal 6.75 (1.92,2.40) (4.88,2.40)
Cargas muertas Lineal 6.75 (4.91,2.38) (4.91,0.16)
Cargas muertas Lineal 6.75 (4.89,0.16) (1.91,0.16)
Cargas muertas Superficial 5.80 (1.99,0.23) (1.99,2.33) (4.81,2.33) (4.81,0.23)
Baja Cargas muertas Puntual 31.76 (0.27,2.58)
MOD-A4-E_Is.00

Cargas muertas Puntual 31.76 (0.27,-0.03)


Cargas muertas Puntual 31.76 (5.75,-0.03)
Cargas muertas Puntual 31.76 (5.75,2.58)
Sobrecarga de uso Puntual 3.69 (0.27,2.58)

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 32 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Grupo Hipótesis Tipo Valor Coordenadas

Sobrecarga de uso Puntual 3.69 (0.27,-0.03)


Sobrecarga de uso Puntual 3.69 (5.75,-0.03)
Sobrecarga de uso Puntual 3.69 (5.75,2.58)
N1 Puntual 0.46 (0.27,2.58)
N1 Puntual 0.46 (0.27,-0.03)
N1 Puntual 0.46 (5.75,-0.03)
N1 Puntual 0.46 (5.75,2.58)

12.3 ESTADOS LÍMITE

E.L.U. de rotura. Hormigón NCh430.Of2008, Dº60:2011


E.L.U. de rotura. Hormigón en cimentaciones
Tensiones sobre el terreno Acciones características
Desplazamientos

12.4 SITUACIONES DE PROYECTO


Para las distintas situaciones de proyecto, las combinaciones de acciones se definirán de acuerdo con
los siguientes criterios:
- Situaciones persistentes o transitorias


j 1
Gj Gkj  PPk    QiQki
i1

- Situaciones sísmicas


j 1
Gj Gkj  PPk   AE A E    QiQki
i 1

- Donde:

Gk Acción permanente
Pk Acción de pretensado
Qk Acción variable
AE Acción sísmica
G Coeficiente parcial de seguridad de las acciones permanentes
P Coeficiente parcial de seguridad de la acción de pretensado
MOD-A4-E_Is.00

Q,1 Coeficiente parcial de seguridad de la acción variable principal


Q,i Coeficiente parcial de seguridad de las acciones variables de acompañamiento
AE Coeficiente parcial de seguridad de la acción sísmica

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 33 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.4.1 COEFICIENTES PARCIALES DE SEGURIDAD () Y COEFICIENTES DE COMBINACIÓN ()

Para cada situación de proyecto y estado límite los coeficientes a utilizar serán:
E.L.U. de rotura. Hormigón: NCh430.Of2008, Dº60:2011
E.L.U. de rotura. Hormigón en cimentaciones: NCh430.Of2008, Dº60:2011

(9-1)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.400 1.400
Sobrecarga (Q)
Viento (Q)
Nieve (Q)

(9-2 Lr)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 1.600
Viento (Q)
Nieve (Q)

(9-2 S)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 1.600
Viento (Q)
Nieve (Q) 0.000 0.500

(9-3 Lr, L)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
Nieve (Q)
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 34 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

(9-3 S, L)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
Nieve (Q) 1.600 1.600

(9-3 Lr, W)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q)
Viento (Q) 0.000 0.800
Nieve (Q)

(9-3 S, W)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q)
Viento (Q) 0.000 0.800
Nieve (Q) 1.600 1.600

(9-4 Lr)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q) 1.600 1.600
Nieve (Q)

(9-4 S)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q) 1.600 1.600
Nieve (Q) 0.000 0.500
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 35 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

(9-5)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
Nieve (Q) 0.000 0.200
Sismo (E) -1.400 1.400

(9-6)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 0.900 0.900
Sobrecarga (Q)
Viento (Q) 0.000 1.600
Nieve (Q)

(9-7)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 0.900 0.900
Sobrecarga (Q)
Viento (Q)
Nieve (Q)
Sismo (E) -1.400 1.400

Tensiones sobre el terreno

Acciones variables sin sismo


Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q) 0.000 1.000
Viento (Q) 0.000 1.000
Nieve (Q) 0.000 1.000

Sísmica
Coeficientes parciales de seguridad ()
Favorable Desfavorable
MOD-A4-E_Is.00

Carga permanente (G) 1.000 1.000


Sobrecarga (Q) 0.000 1.000
Viento (Q)
Nieve (Q) 0.000 1.000
Sismo (E) -1.000 1.000

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 36 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Desplazamientos

Acciones variables sin sismo


Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q) 0.000 1.000
Viento (Q) 0.000 1.000
Nieve (Q) 0.000 1.000

Sísmica
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q) 0.000 1.000
Viento (Q)
Nieve (Q) 0.000 1.000
Sismo (E) -1.000 1.000

12.4.2 COMBINACIONES
- Nombres de las hipótesis

PP Peso propio
CM Cargas muertas
Qa Sobrecarga de uso
V (0º) V (0º)
V (90º) V (90º)
V (180º) V (180º)
V (270º) V (270º)
N1 N1
SX 1 Sismo X 1
SX 2 Sismo X 2
SY 1 Sismo Y 1
SY 2 Sismo Y 2
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 37 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

- E.L.U. de rotura. Hormigón


- E.L.U. de rotura. Hormigón en cimentaciones

Comb. PP CM Qa V (0º) V (90º) V (180º) V (270º) N 1 SX 1 SX 2 SY 1 SY 2


1 1.400 1.400
2 1.200 1.200
3 1.200 1.200 1.600
4 1.200 1.200 1.600 0.500
5 1.200 1.200 1.600
6 1.200 1.200 0.500 1.600
7 1.200 1.200 0.800 1.600
8 1.200 1.200 0.800 1.600
9 1.200 1.200 0.800 1.600
10 1.200 1.200 0.800 1.600
11 1.200 1.200 1.600
12 1.200 1.200 0.500 1.600
13 1.200 1.200 1.600
14 1.200 1.200 0.500 1.600
15 1.200 1.200 1.600
16 1.200 1.200 0.500 1.600
17 1.200 1.200 1.600
18 1.200 1.200 0.500 1.600
19 1.200 1.200 1.600 0.500
20 1.200 1.200 0.500 1.600 0.500
21 1.200 1.200 1.600 0.500
22 1.200 1.200 0.500 1.600 0.500
23 1.200 1.200 1.600 0.500
24 1.200 1.200 0.500 1.600 0.500
25 1.200 1.200 1.600 0.500
26 1.200 1.200 0.500 1.600 0.500
27 1.200 1.200 -1.400
28 1.200 1.200 0.500 -1.400
29 1.200 1.200 0.200 -1.400
30 1.200 1.200 0.500 0.200 -1.400
31 1.200 1.200 1.400
32 1.200 1.200 0.500 1.400
33 1.200 1.200 0.200 1.400
34 1.200 1.200 0.500 0.200 1.400
35 1.200 1.200 -1.400
36 1.200 1.200 0.500 -1.400
37 1.200 1.200 0.200 -1.400
38 1.200 1.200 0.500 0.200 -1.400
39 1.200 1.200 1.400
MOD-A4-E_Is.00

40 1.200 1.200 0.500 1.400


41 1.200 1.200 0.200 1.400
42 1.200 1.200 0.500 0.200 1.400
43 1.200 1.200 -1.400

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 38 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Comb. PP CM Qa V (0º) V (90º) V (180º) V (270º) N 1 SX 1 SX 2 SY 1 SY 2


44 1.200 1.200 0.500 -1.400
45 1.200 1.200 0.200 -1.400
46 1.200 1.200 0.500 0.200 -1.400
47 1.200 1.200 1.400
48 1.200 1.200 0.500 1.400
49 1.200 1.200 0.200 1.400
50 1.200 1.200 0.500 0.200 1.400
51 1.200 1.200 -1.400
52 1.200 1.200 0.500 -1.400
53 1.200 1.200 0.200 -1.400
54 1.200 1.200 0.500 0.200 -1.400
55 1.200 1.200 1.400
56 1.200 1.200 0.500 1.400
57 1.200 1.200 0.200 1.400
58 1.200 1.200 0.500 0.200 1.400
59 0.900 0.900
60 0.900 0.900 1.600
61 0.900 0.900 1.600
62 0.900 0.900 1.600
63 0.900 0.900 1.600
64 0.900 0.900 -1.400
65 0.900 0.900 1.400
66 0.900 0.900 -1.400
67 0.900 0.900 1.400
68 0.900 0.900 -1.400
69 0.900 0.900 1.400
70 0.900 0.900 -1.400
71 0.900 0.900 1.400

- Tensiones sobre el terreno


- Desplazamientos

Comb. PP CM Qa V (0º) V (90º) V (180º) V (270º) N 1 SX 1 SX 2 SY 1 SY 2


1 1.000 1.000
2 1.000 1.000 1.000
3 1.000 1.000 1.000
4 1.000 1.000 1.000 1.000
5 1.000 1.000 1.000
6 1.000 1.000 1.000 1.000
7 1.000 1.000 1.000
8 1.000 1.000 1.000 1.000
MOD-A4-E_Is.00

9 1.000 1.000 1.000


10 1.000 1.000 1.000 1.000
11 1.000 1.000 1.000
12 1.000 1.000 1.000 1.000

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 39 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Comb. PP CM Qa V (0º) V (90º) V (180º) V (270º) N 1 SX 1 SX 2 SY 1 SY 2


13 1.000 1.000 1.000 1.000
14 1.000 1.000 1.000 1.000 1.000
15 1.000 1.000 1.000 1.000
16 1.000 1.000 1.000 1.000 1.000
17 1.000 1.000 1.000 1.000
18 1.000 1.000 1.000 1.000 1.000
19 1.000 1.000 1.000 1.000
20 1.000 1.000 1.000 1.000 1.000
21 1.000 1.000 -1.000
22 1.000 1.000 1.000 -1.000
23 1.000 1.000 1.000 -1.000
24 1.000 1.000 1.000 1.000 -1.000
25 1.000 1.000 1.000
26 1.000 1.000 1.000 1.000
27 1.000 1.000 1.000 1.000
28 1.000 1.000 1.000 1.000 1.000
29 1.000 1.000 -1.000
30 1.000 1.000 1.000 -1.000
31 1.000 1.000 1.000 -1.000
32 1.000 1.000 1.000 1.000 -1.000
33 1.000 1.000 1.000
34 1.000 1.000 1.000 1.000
35 1.000 1.000 1.000 1.000
36 1.000 1.000 1.000 1.000 1.000
37 1.000 1.000 -1.000
38 1.000 1.000 1.000 -1.000
39 1.000 1.000 1.000 -1.000
40 1.000 1.000 1.000 1.000 -1.000
41 1.000 1.000 1.000
42 1.000 1.000 1.000 1.000
43 1.000 1.000 1.000 1.000
44 1.000 1.000 1.000 1.000 1.000
45 1.000 1.000 -1.000
46 1.000 1.000 1.000 -1.000
47 1.000 1.000 1.000 -1.000
48 1.000 1.000 1.000 1.000 -1.000
49 1.000 1.000 1.000
50 1.000 1.000 1.000 1.000
51 1.000 1.000 1.000 1.000
52 1.000 1.000 1.000 1.000 1.000
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 40 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.5 DATOS GEOMÉTRICOS DE GRUPOS Y PLANTAS

Grupo Nombre del grupo Planta Nombre planta Altura Cota


1 Baja 1 Baja 1.35 1.35
0 Cimentación 0.00

12.6 DATOS GEOMÉTRICOS DE PILARES


12.6.1 PILARES
GI: grupo inicial
GF: grupo final
Ang: ángulo del pilar en grados sexagesimales

Datos de los pilares


Referencia Coord(P.Fijo) GI- GF Vinculación exterior Ang. Punto fijo
F1 ( -0.20, 2.75) 0-1 Sin vinculación exterior 0.0 Esq. sup. izq.
F2 ( -0.20, -0.20) 0-1 Sin vinculación exterior 0.0 Esq. inf. izq.
F3 ( 3.01, 2.75) 0-1 Sin vinculación exterior 0.0 Mitad superior
F4 ( 3.01, -0.20) 0-1 Sin vinculación exterior 0.0 Mitad inferior
F5 ( 6.22, 2.75) 0-1 Sin vinculación exterior 0.0 Esq. sup. der.
F6 ( 6.22, -0.20) 0-1 Sin vinculación exterior 0.0 Esq. inf. der.

12.7 DIMENSIONES, COEFICIENTES DE EMPOTRAMIENTO Y COEFICIENTES DE


PANDEO PARA CADA PLANTA

Para todos los pilares


Dimensiones Coeficiente de empotramiento Coeficiente de pandeo
Planta Coeficiente de rigidez axil
(cm) Cabeza Pie X Y
1 40x40 0.30 1.00 1.00 1.00 2.00

12.8 LOSAS Y ELEMENTOS DE CIMENTACIÓN

Losas cimentación Canto (cm) Módulo balasto (kN/m³) Tensión admisible Tensión admisible
en situaciones en situaciones
persistentes (MPa) accidentales (MPa)
MOD-A4-E_Is.00

Todas 30 3548.10 0.075 0.100

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 41 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.9 MATERIALES UTILIZADOS


12.9.1 HORMIGONES

f'c Tamaño máximo del árido Ec


Elemento Hormigón
(MPa) (mm) (MPa)
Vigas y losas de cimentación H25 20 20 20810
Forjados H25 20 15 20810
Pilares y pantallas H25 20 15 20810
Muros H25 20 15 20810

12.9.2 ACEROS POR ELEMENTO Y POSICIÓN


12.9.2.1 ACEROS EN BARRAS

fyk
Elemento Acero s
(MPa)
Todos A-63-42H 412 1.00

12.9.2.2 ACEROS EN PERFILES

Límite elástico Módulo de elasticidad


Tipo de acero para perfiles Acero
(MPa) (GPa)
Acero conformado A37-24ES 235 206
Acero laminado A42-27ES 265 206

12.10 JUSTIFICACIÓN DE LA ACCIÓN SÍSMICA


Norma utilizada: NCh2369
Norma Chilena Oficial
Diseño Sísmico de Edificios
Diseño Sísmico de Estructuras e Instalaciones Industriales

Método de cálculo: Análisis Estático (NCh42369, SECCIÓN 5.2.2)

12.10.1 DATOS GENERALES DE SISMO

Caracterización del emplazamiento


MOD-A4-E_Is.00

Zona sísmica (NCh2369): 3


Clase de suelo (NCh2369): E

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 42 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Sistema estructural
RX: Factor de modificación de la respuesta estático (X) (NCh2369) RX : 7.00
RY: Factor de modificación de la respuesta estático (Y) (NCh2369) RY : 7.00

Estimación del periodo fundamental de la estructura


TX*: Periodo fundamental aproximado (X) TX* : 0.50 s
TY*: Periodo fundamental aproximado (Y) TY* : 0.50 s

Parámetros de cálculo
Fracción de sobrecarga de uso : 0.50
Fracción de sobrecarga de nieve : 0.50
Factor multiplicador del espectro : 1.00

Efectos de la componente sísmica vertical


No se consideran

No se realiza análisis de los efectos de 2º orden

Criterio de armado a aplicar por ductilidad: Según NCh430.Of2008, Capítulo 21

Direcciones de análisis
Acción sísmica según X
Acción sísmica según Y

Proyección en planta de la obra


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 43 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.10.2 ESPECTRO DE CÁLCULO


12.10.2.1 ESPECTRO ELÁSTICO DE ACELERACIONES

Coef.Amplificación:
n
T '
S ae  I  2, 75  S  A0  
T 
I  S  A0 / 6  S ae  (Cmax  R)  I

Donde:
(Cmax  R )  MAX (Cmax, x  Rx ; Cmax, y  Ry )

El valor máximo de las ordenadas espectrales es 1.529 g.

Parámetros necesarios para la definición del espectro

A0: Aceleración efectiva (NCh2369, Tabla 6.2) A0 : 0.40 g


Zona sísmica (NCh2369, 4.1): 2

S: Parámetro que interviene en la obtención del espectro de diseño y que


depende del tipo de suelo (NCh2369) S : 1.30
T': Parámetro que interviene en la obtención del espectro de diseño y que
depende del tipo de suelo (NCh2369) T' : 1.35
n: Parámetro que interviene en la obtención del espectro de diseño y que
depende del tipo de suelo (NCh2369) n : 1.80
Clase de suelo (NCh2369): E

Cmax,X: Valor máximo del coeficiente sísmico C (X) Cmax,X : 0.18 g


Cmax, x  0,35  S  Ao

RX: Factor de modificación de la respuesta estático (X) (NCh2369) RX : 7.00


Cmax,Y: Valor máximo del coeficiente sísmico C (Y) Cmax,Y : 0.18 g
Cmax, y  0,35  S  Ao

RY: Factor de modificación de la respuesta estático (Y) (NCh2369) RY : 7.00


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 44 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.10.2.2 ESPECTRO DE DISEÑO DE ACELERACIONES

El espectro de diseño sísmico se obtiene reduciendo el espectro elástico por el coeficiente (R)
correspondiente a cada dirección de análisis.
I  2, 75  S  A0  T ' 
n

Sa    I  S  A0 / 6  S a  Cmax  I
R T 

Cmax,X: Valor máximo del coeficiente sísmico C (X) Cmax,X : 0.18 g


Cmax, x  0,35  S  Ao

RX: Factor de modificación de la respuesta estático (X) (NCh 2369) RX : 7.00


Cmax,Y: Valor máximo del coeficiente sísmico C (Y) Cmax,Y : 0.18 g
Cmax, y  0,35  S  Ao

RY: Factor de modificación de la respuesta estático (Y) (NCh 2369) RY : 7.00

Espectro de diseño según X Espectro de diseño según Y

12.10.3 FUERZAS LATERALES EQUIVALENTES


12.10.3.1 ESTIMACIÓN DEL PERIODO FUNDAMENTAL DE LA ESTRUCTURA

El periodo fundamental aproximado de la estructura se estima para cada una de las


direcciones de análisis:
TX*: Periodo fundamental aproximado (X) TX* : 0.50 s
MOD-A4-E_Is.00

TY*: Periodo fundamental aproximado (Y) TY* : 0.50 s

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 45 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.10.3.2 CORTANTE BASAL DE DISEÑO

El cortante sísmico en la base de la estructura se determina para cada una


de las direcciones de análisis:
VS,X: Cortante sísmico en la base (X) (NCh2369) VS,X : 76.808 kN
Vs , x  S ax (Ta , x )  P

Sa,X(TX*): Aceleración espectral horizontal de diseño (X) Sa,X(TX*) : 0.218 g


n
I  2, 75  S  A0  T ' 
S ax    I  S  A0 / 6  S ax  Cx ,max  I
Rx  Ta , x 
TX*: Periodo fundamental aproximado (X) TX* : 0.50 s

VS,Y: Cortante sísmico en la base (Y) (NCh2369) VS,Y : 76.808 kN


Vs , y  S ay (Ta , y )  P

Sa,Y(TY*): Aceleración espectral horizontal de diseño (Y) Sa,Y(TY*) : 0.218 g


n
I  2, 75  S  A0  T ' 
S ay    I  S  A0 / 6  S ay  C y ,max  I
Ry  Ta , y 
TY*: Periodo fundamental aproximado (Y) TY* : 0.50 s

P: Peso sísmico total de la estructura P : 351.683 kN


El peso sísmico total de la estructura es la suma de los pesos sísmicos de
todas las plantas.

n
P p
i 1
i

pi: Peso sísmico total de la planta "i"


Suma de la totalidad de la carga permanente y de la fracción de la
sobrecarga de uso considerada en el cálculo de la acción sísmica.

pi
Planta
(kN)
Baja 351.683
P=pi 351.683

12.10.3.3 DISTRIBUCIÓN VERTICAL DEL CORTANTE BASAL

Factor de distribución vertical


El cortante sísmico en la base de la estructura se distribuye a lo largo de la altura
MOD-A4-E_Is.00

del edificio mediante fuerzas laterales equivalentes que se obtienen multiplicando el


cortante basal por un factor de distribución vertical por planta (NCh2369):

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 46 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

pi ꞏAi
Ci  n

 p ꞏA
j 1
j j

Ci: Factor de distribución vertical de la planta "i"


pi: Peso sísmico total de la planta "i"
zi: Altura de la planta "i", medida desde la rasante
n: Número de plantas sobre rasante
Ai: Coeficiente que depende de la altura de la planta "i", medida desde la
rasante
zi 1 z
Ai  1   1 i
h h
h: Altura del edificio h : 1.35

pi zi
Planta Ci
(kN) (m)
Baja 351.683 1.35 1.000

Distribución de las fuerzas laterales y cortantes equivalentes por planta


Qi,X: Fuerza lateral equivalente de diseño de la planta "i" (X)
Qi,Y: Fuerza lateral equivalente de diseño de la planta "i" (Y)
Qi,x  Ci  VS,x

Qi,y  Ci  VS,y

VS,X: Cortante sísmico en la base (X) (NCh2369) VS,X : 76.808 kN


VS,Y: Cortante sísmico en la base (Y) (NCh2369) VS,Y : 76.808 kN
Vi,X: Cortante equivalente de diseño en la planta "i" (X)
Vi,Y: Cortante equivalente de diseño en la planta "i" (Y)

Qi,X Vi,X Qi,Y Vi,Y


Planta Ci
(kN) (kN) (kN) (kN)
Baja 1.000 76.81 76.81 76.81 76.81

12.10.4 CENTRO DE MASAS, CENTRO DE RIGIDEZ Y EXCENTRICIDADES DE CADA PLANTA

c.d.m. c.d.r. z eX eY ed,X ed,Y bX bY


Planta
(m) (m) (m) (m) (m) (m) (m) (m) (m)
ed,X1 = 0.64 ed,Y1 = 0.30
Baja (3.01, 1.28) (3.01, 1.28) 1.35 0.00 0.00 6.42 2.95
ed,X2 = -0.64 ed,Y2 = -0.30
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 47 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

c.d.r.: Coordenadas del centro de rigidez de la planta (X,Y)


eX: Excentricidad del centro de masas respecto al centro de rigidez (X)
eY: Excentricidad del centro de masas respecto al centro de rigidez (Y)
ed,X: Excentricidad de diseño "X" para la acción sísmica actuando en la dirección Y
e  0.10  ( zi h )  bXi
ed,X   X
eX  0.10  ( zi h )  bXi
bX: Dimensión de la planta, medida en la dirección perpendicular a la acción sísmica Y
ed,Y: Excentricidad de diseño "Y" para la acción sísmica actuando en la dirección X
eY  0.10  ( zi h )  bYi
ed,Y  
eY  0.10  ( zi h )  b Yi
bY: Dimensión de la planta, medida en la dirección perpendicular a la acción sísmica X

12.11 LOSA DE CIMENTACIÓN


12.11.1 ESFUERZOS EN NUDOS DE LA LOSA
12.11.1.1 TABLA DE ESFUERZOS
Cortantes en KN. Momentos en KN x m.

Coord. X y Coord. Y son coordenadas generales. Los esfuerzos están referidos a los ejes locales de
la malla correspondiente.

Esquema malla y coordenadas en programa Cypecad:


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 48 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Imagen 16 Esquema de malla y coordenadas en el programa cálculo Cypecad

Envolventes de esfuerzos mayorados


Cimentación
Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY
0.050 0.277 Máx. 62.5267 36.8270 6.3861 12.0092 6.0347 0.259 1.777 Máx. 17.8831 1.6937 -0.0799 0.9982 0.1015
Mín. -8.3913 5.2258 -0.3074 -16.1494 -9.6570 Mín. -0.2985 -27.0775 -6.9441 -18.8747 -4.8394
Dif. 70.9180 31.6011 6.6935 28.1586 15.6917 Dif. 18.1816 28.7712 6.8642 19.8729 4.9409
0.050 0.527 Máx. 34.1450 27.7909 0.7702 8.2659 5.7368 0.259 2.027 Máx. 29.8102 -8.3335 1.1295 8.2620 0.9164
Mín. -4.8253 8.3412 -0.3380 -18.6413 -1.4599 Mín. -2.2170 -27.7805 -9.5794 -18.6465 -5.6311
Dif. 38.9702 19.4497 1.1082 26.9072 7.1967 Dif. 32.0272 19.4470 10.7090 26.9085 6.5474
0.050 0.777 Máx. 18.4908 27.0902 0.0699 1.0014 4.9346 0.259 2.277 Máx. 46.3224 -5.2199 4.7044 12.0063 5.7772
Mín. -0.6865 -1.6843 -0.4962 -18.8704 -0.3163 Mín. 1.8790 -36.8187 -12.8242 -16.1533 -5.7489
Dif. 19.1773 28.7745 0.5661 19.8718 5.2509 Dif. 44.4435 31.5988 17.5286 28.1596 11.5261
0.050 1.027 Máx. 11.1079 21.2241 -0.0439 -5.3191 2.7081 0.259 2.504 Máx. 46.3224 8.6875 4.7044 8.6058 7.6373
Mín. 1.3563 -8.3447 -0.5722 -17.4218 -0.0719 Mín. 1.8790 -52.0223 -12.8242 -1.0431 -3.8873
Dif. 9.7516 29.5688 0.5283 12.1027 2.7800 Dif. 44.4435 60.7098 17.5286 9.6489 11.5247
0.050 1.277 Máx. 9.3885 13.9785 -0.0732 -8.2707 0.9424 0.509 0.050 Máx. 23.4279 31.8230 3.0517 0.9287 8.8757
Mín. 1.5481 -13.9658 -0.5799 -16.1054 -0.9378 Mín. 14.1759 -10.0793 -17.0968 -0.3211 -5.4427
Dif. 7.8404 27.9442 0.5066 7.8347 1.8802 Dif. 9.2520 41.9023 20.1485 1.2497 14.3184
0.050 1.527 Máx. 11.1077 8.3552 -0.0440 -5.3209 0.0756 0.509 0.277 Máx. 23.4279 25.3160 3.0517 4.9580 8.6808
Mín. 1.3562 -21.2100 -0.5723 -17.4242 -2.7032 Mín. 14.1759 -3.4356 -17.0968 -11.0556 -4.5014
Dif. 9.7515 29.5652 0.5283 12.1033 2.7787 Dif. 9.2520 28.7516 20.1485 16.0136 13.1822
0.050 1.777 Máx. 18.4907 1.6937 0.0696 0.9982 0.3192 0.509 0.527 Máx. 19.4851 14.9298 0.6416 4.1894 6.1909
Mín. -0.6866 -27.0775 -0.4965 -18.8747 -4.9308 Mín. 2.5739 5.2669 -14.6612 -14.9988 -1.2790
Dif. 19.1773 28.7712 0.5662 19.8729 5.2500 Dif. 16.9112 9.6629 15.3028 19.1882 7.4700
0.050 2.027 Máx. 34.1456 -8.3335 0.7694 8.2620 1.4611 0.509 0.777 Máx. 14.1481 14.9281 -0.6044 0.0737 3.7844
Mín. -4.8248 -27.7805 -0.3386 -18.6465 -5.7353 Mín. 0.8166 0.2457 -12.1180 -16.0200 0.3889
Dif. 38.9704 19.4470 1.1080 26.9085 7.1964 Dif. 13.3314 14.6824 11.5136 16.0937 3.3955
0.050 2.277 Máx. 62.5272 -5.2199 6.3827 12.0063 9.6534 0.509 1.027 Máx. 9.1950 14.0494 -1.1944 -4.6082 2.0199
Mín. -8.3909 -36.8187 -0.3098 -16.1533 -6.0373 Mín. 1.8565 -5.9957 -10.4296 -14.9655 0.3243
Dif. 70.9181 31.5988 6.6926 28.1596 15.6907 Dif. 7.3385 20.0451 9.2352 10.3574 1.6956
0.259 0.050 Máx. 46.3255 52.0295 4.7089 8.6097 3.8842 0.509 1.277 Máx. 7.8842 10.2533 -1.4507 -7.8734 0.3706
Mín. 1.8812 -8.6824 -12.8181 -1.0402 -7.6417 Mín. 1.8965 -10.2450 -9.7746 -13.6846 -0.3645
Dif. 44.4443 60.7119 17.5270 9.6499 11.5259 Dif. 5.9877 20.4983 8.3240 5.8112 0.7350
0.259 0.277 Máx. 46.3255 36.8270 4.7089 12.0092 5.7476 0.509 1.527 Máx. 9.1931 6.0026 -1.1949 -4.6094 -0.3192
Mín. 1.8812 5.2258 -12.8181 -16.1494 -5.7786 Mín. 1.8551 -14.0401 -10.4303 -14.9672 -2.0131
Dif. 44.4443 31.6011 17.5270 28.1586 11.5262 Dif. 7.3380 20.0427 9.2354 10.3578 1.6939
0.259 0.527 Máx. 29.8114 27.7909 1.1314 8.2659 5.6336 0.509 1.777 Máx. 14.1445 -0.2395 -0.6058 0.0716 -0.3843
Mín. -2.2161 8.3412 -9.5769 -18.6413 -0.9144 Mín. 0.8140 -14.9197 -12.1199 -16.0227 -3.7783
Dif. 32.0275 19.4497 10.7083 26.9072 6.5480 Dif. 13.3305 14.6802 11.5141 16.0944 3.3940
0.259 0.777 Máx. 17.8842 27.0902 -0.0791 1.0014 4.8442 0.509 2.027 Máx. 19.4798 -5.2615 0.6386 4.1873 1.2828
Mín. -0.2977 -1.6843 -6.9429 -18.8704 -0.0979 Mín. 2.5700 -14.9225 -14.6653 -15.0016 -6.1860
Dif. 18.1819 28.7745 6.8639 19.8718 4.9421 Dif. 16.9098 9.6610 15.3039 19.1889 7.4688
0.259 1.027 Máx. 10.9681 21.2241 -0.5154 -5.3191 2.7163 0.509 2.277 Máx. 23.4176 3.4398 3.0459 4.9570 4.5040
Mín. 1.6259 -8.3447 -5.5416 -17.4218 0.0138 Mín. 14.1687 -25.3103 -17.1048 -11.0569 -8.6774
Dif. 9.3422 29.5688 5.0262 12.1027 2.7025 Dif. 9.2489 28.7501 20.1506 16.0140 13.1814
0.259 1.277 Máx. 9.3473 13.9785 -0.6803 -8.2707 0.7056 0.509 2.504 Máx. 23.4176 10.0827 3.0459 0.9276 5.4445
MOD-A4-E_Is.00

Mín. 1.7400 -13.9658 -5.0648 -16.1054 -0.7002 Mín. 14.1687 -31.8182 -17.1048 -0.3218 -8.8734
Dif. 7.6073 27.9442 4.3845 7.8347 1.4058 Dif. 9.2489 41.9010 20.1506 1.2495 14.3179
0.259 1.527 Máx. 10.9674 8.3552 -0.5158 -5.3209 -0.0094 0.759 0.050 Máx. 18.6931 16.8212 -0.7692 0.2133 8.3551
Mín. 1.6254 -21.2100 -5.5421 -17.4242 -2.7104 Mín. 3.5239 -3.3844 -19.6850 -0.5348 -4.1342
Dif. 9.3420 29.5652 5.0263 12.1033 2.7011 Dif. 15.1691 20.2056 18.9158 0.7481 12.4893

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 49 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY
0.759 0.277 Máx. 18.6931 14.7553 -0.7692 1.7217 8.3093 1.259 1.027 Máx. -1.2813 6.1369 -3.5477 -4.6436 2.3918
Mín. 3.5239 -1.0347 -19.6850 -7.1479 -3.8472 Mín. -6.8722 -2.7048 -14.1101 -9.8653 -2.1780
Dif. 15.1691 15.7900 18.9158 8.8696 12.1564 Dif. 5.5909 8.8416 10.5624 5.2217 4.5698
0.759 0.527 Máx. 9.1324 10.4943 -1.3784 1.3750 6.3083 1.259 1.277 Máx. -1.6095 4.5482 -3.4778 -5.9259 2.1179
Mín. 4.6466 2.5325 -17.5311 -11.2936 -2.1689 Mín. -6.6480 -4.5453 -13.6148 -10.2005 -2.1130
Dif. 4.4858 7.9618 16.1527 12.6685 8.4771 Dif. 5.0386 9.0935 10.1370 4.2747 4.2309
0.759 0.777 Máx. 7.5321 9.5996 -1.8654 -1.0949 4.1393 1.259 1.527 Máx. -1.2836 2.7058 -3.5455 -4.6458 2.1827
Mín. 1.4158 0.4374 -15.3263 -13.0280 -0.9308 Mín. -6.8753 -6.1355 -14.1072 -9.8683 -2.3855
Dif. 6.1163 9.1622 13.4609 11.9330 5.0700 Dif. 5.5917 8.8413 10.5617 5.2225 4.5682
0.759 1.027 Máx. 5.2408 9.4535 -2.1826 -4.3934 2.3190 1.259 1.777 Máx. -0.3778 0.4174 -3.9108 -2.7302 2.5158
Mín. 1.1337 -4.0350 -13.7265 -12.6468 -0.5676 Mín. -7.4411 -6.5756 -15.3540 -9.2922 -2.9284
Dif. 4.1071 13.4885 11.5438 8.2533 2.8866 Dif. 7.0633 6.9930 11.4432 6.5620 5.4442
0.759 1.277 Máx. 4.0767 7.2519 -2.3793 -7.2442 0.9914 1.259 2.027 Máx. 1.2131 -1.6881 -4.5667 -1.1629 2.9848
Mín. 1.4468 -7.2461 -13.0637 -11.9283 -0.9849 Mín. -8.2497 -5.7858 -17.1509 -7.1712 -3.6129
Dif. 2.6298 14.4981 10.6844 4.6841 1.9763 Dif. 9.4628 4.0977 12.5842 6.0083 6.5976
0.759 1.527 Máx. 5.2377 4.0397 -2.1828 -4.3945 0.5731 1.259 2.277 Máx. 3.7989 -2.1153 -5.4751 -0.3547 3.2986
Mín. 1.1314 -9.4471 -13.7267 -12.6482 -2.3116 Mín. -9.2332 -5.2091 -19.2144 -3.8275 -4.1227
Dif. 4.1063 13.4868 11.5439 8.2537 2.8847 Dif. 13.0321 3.0938 13.7394 3.4728 7.4212
0.759 1.777 Máx. 7.5257 -0.4333 -1.8663 -1.0965 0.9363 1.259 2.504 Máx. 3.7989 -1.2373 -5.4751 0.0090 3.0309
Mín. 1.4111 -9.5940 -15.3275 -13.0301 -4.1318 Mín. -9.2332 -5.7226 -19.2144 -0.5852 -3.8707
Dif. 6.1146 9.1607 13.4612 11.9336 5.0682 Dif. 13.0321 4.4852 13.7394 0.5942 6.9016
0.759 2.027 Máx. 9.1220 -2.5288 -1.3808 1.3736 2.1742 1.509 0.050 Máx. -1.2621 4.4974 -5.8929 -0.0106 1.7184
Mín. 4.6390 -10.4893 -17.5343 -11.2955 -6.3010 Mín. -18.2254 1.7617 -15.9214 -0.5762 -3.0930
Dif. 4.4830 7.9605 16.1535 12.6690 8.4753 Dif. 16.9633 2.7356 10.0285 0.5656 4.8114
0.759 2.277 Máx. 18.6766 1.0376 -0.7738 1.7211 3.8521 1.509 0.277 Máx. -1.2621 4.7343 -5.8929 -0.5922 1.9174
Mín. 3.5117 -14.7513 -19.6913 -7.1487 -8.3027 Mín. -18.2254 2.3911 -15.9214 -3.4248 -3.4925
Dif. 15.1649 15.7889 18.9175 8.8698 12.1548 Dif. 16.9633 2.3432 10.0285 2.8326 5.4099
0.759 2.504 Máx. 18.6766 3.3867 -0.7738 0.2128 4.1384 1.509 0.527 Máx. -2.5539 6.0372 -4.7298 -1.6027 1.9134
Mín. 3.5117 -16.8181 -19.6913 -0.5354 -8.3495 Mín. -15.6013 1.5790 -13.9080 -6.6879 -3.4493
Dif. 15.1649 20.2047 18.9175 0.7482 12.4879 Dif. 13.0474 4.4582 9.1782 5.0852 5.3627
1.009 0.050 Máx. 11.0804 9.1853 -3.7781 0.0697 6.2588 1.509 0.777 Máx. -3.3237 6.7855 -3.7947 -3.2111 1.9190
Mín. -2.5163 -0.1373 -20.4357 -0.5925 -3.3791 Mín. -13.6946 -0.3017 -12.2688 -8.9385 -3.1168
Dif. 13.5967 9.3226 16.6576 0.6622 9.6378 Dif. 10.3709 7.0872 8.4741 5.7274 5.0359
1.009 0.277 Máx. 11.0804 8.3919 -3.7781 0.2818 6.4668 1.509 1.027 Máx. -3.7924 6.1881 -3.2066 -5.0003 2.0239
Mín. -2.5163 0.9821 -20.4357 -4.9271 -3.4656 Mín. -12.4230 -2.5268 -11.1973 -9.7786 -2.6746
Dif. 13.5967 7.4098 16.6576 5.2089 9.9324 Dif. 8.6306 8.7148 7.9907 4.7783 4.6984
1.009 0.527 Máx. 5.1228 7.1748 -3.3606 -0.2747 5.2850 1.509 1.277 Máx. -4.0005 4.4504 -3.0246 -5.6198 2.2486
Mín. -1.3849 2.0219 -18.3494 -8.6473 -2.6714 Mín. -11.9242 -4.4460 -10.8048 -10.3839 -2.2463
Dif. 6.5077 5.1529 14.9888 8.3726 7.9564 Dif. 7.9237 8.8964 7.7802 4.7641 4.4949
1.009 0.777 Máx. 2.1920 7.3606 -3.1563 -2.0539 3.8131 1.509 1.527 Máx. -3.7922 2.5279 -3.2030 -5.0041 2.6780
Mín. -1.1141 -0.0630 -16.3955 -10.6687 -1.8825 Mín. -12.4227 -6.1865 -11.1925 -9.7836 -2.0213
Dif. 3.3061 7.4236 13.2392 8.6148 5.6957 Dif. 8.6305 8.7144 7.9895 4.7795 4.6994
1.009 1.027 Máx. 0.7014 7.0023 -3.0998 -4.4429 2.5558 1.509 1.777 Máx. -3.3261 0.2949 -3.7874 -3.2172 3.1225
Mín. -1.1378 -3.0083 -14.9793 -10.8602 -1.5262 Mín. -13.6978 -6.7945 -12.2591 -8.9467 -1.9148
Dif. 1.8392 10.0107 11.8796 6.4172 4.0820 Dif. 10.3718 7.0894 8.4717 5.7295 5.0374
1.009 1.277 Máx. 0.2567 5.3610 -3.1651 -6.5264 1.7076 1.509 2.027 Máx. -2.5682 -1.5963 -4.7194 -1.6077 3.4587
Mín. -1.2217 -5.3571 -14.3910 -10.7369 -1.7014 Mín. -15.6205 -6.0603 -13.8942 -6.6946 -1.9065
Dif. 1.4784 10.7181 11.2258 4.2106 3.4090 Dif. 13.0523 4.4639 9.1748 5.0869 5.3651
1.009 1.527 Máx. 0.6975 3.0110 -3.0990 -4.4442 1.5318 1.509 2.277 Máx. -1.3109 -2.4017 -5.8832 -0.5921 3.5037
Mín. -1.1417 -6.9987 -14.9784 -10.8619 -2.5483 Mín. -18.2905 -4.7485 -15.9084 -3.4247 -1.9091
Dif. 1.8392 10.0097 11.8793 6.4177 4.0801 Dif. 16.9797 2.3468 10.0253 2.8326 5.4128
1.009 1.777 Máx. 2.1830 0.0645 -3.1554 -2.0558 1.8886 1.509 2.504 Máx. -1.3109 -1.7606 -5.8832 -0.0108 3.1029
Mín. -1.1208 -7.3586 -16.3944 -10.6713 -3.8049 Mín. -18.2905 -4.4959 -15.9084 -0.5764 -1.7110
Dif. 3.3039 7.4231 13.2390 8.6155 5.6936 Dif. 16.9797 2.7352 10.0253 0.5657 4.8139
1.009 2.027 Máx. 5.1071 -2.0210 -3.3606 -0.2762 2.6780 1.759 0.050 Máx. -5.4376 5.2317 -3.9038 0.0076 0.0453
Mín. -1.3966 -7.1736 -18.3495 -8.6493 -5.2761 Mín. -26.3946 1.2722 -11.4768 -0.5706 -3.7329
Dif. 6.5037 5.1526 14.9889 8.3731 7.9541 Dif. 20.9570 3.9595 7.5730 0.5782 3.7782
1.009 2.277 Máx. 11.0560 -0.9811 -3.7800 0.2813 3.4721 1.759 0.277 Máx. -5.4376 6.4220 -3.9038 -0.5106 -0.0358
Mín. -2.5344 -8.3905 -20.4383 -4.9278 -6.4580 Mín. -26.3946 1.8999 -11.4768 -3.5508 -4.0187
Dif. 13.5905 7.4094 16.6583 5.2091 9.9301 Dif. 20.9570 4.5221 7.5730 3.0402 3.9829
1.009 2.504 Máx. 11.0560 0.1384 -3.7800 0.0694 3.3848 1.759 0.527 Máx. -5.2552 7.5217 -3.5971 -1.7441 0.2406
Mín. -2.5344 -9.1837 -20.4383 -0.5929 -6.2511 Mín. -20.8334 2.5177 -8.6567 -7.1366 -3.9705
Dif. 13.5905 9.3221 16.6583 0.6623 9.6359 Dif. 15.5783 5.0040 5.0596 5.3925 4.2111
1.259 0.050 Máx. 3.8266 5.7231 -5.4775 0.0092 3.8797 1.759 0.777 Máx. -5.1693 8.2530 -2.5382 -3.5899 0.8598
Mín. -9.1964 1.2377 -19.2176 -0.5849 -3.0242 Mín. -17.2838 0.1916 -7.3055 -9.6148 -3.6534
Dif. 13.0229 4.4854 13.7401 0.5941 6.9039 Dif. 12.1145 8.0614 4.7673 6.0249 4.5133
1.259 0.277 Máx. 3.8266 5.2059 -5.4775 -0.3542 4.1329 1.759 1.027 Máx. -5.1221 7.2870 -1.8390 -5.3541 1.5357
Mín. -9.1964 2.1129 -19.2176 -3.8269 -3.2909 Mín. -15.1384 -2.5698 -6.4821 -10.7492 -3.0239
MOD-A4-E_Is.00

Dif. 13.0229 3.0930 13.7401 3.4726 7.4238 Dif. 10.0163 9.8569 4.6431 5.3950 4.5596
1.259 0.527 Máx. 1.2287 5.7793 -4.5708 -1.1604 3.6227 1.759 1.277 Máx. -5.1496 4.9709 -1.6016 -5.7330 2.1959
Mín. -8.2289 1.6831 -17.1563 -7.1679 -2.9775 Mín. -14.3614 -4.9620 -6.1967 -11.3902 -2.1972
Dif. 9.4576 4.0961 12.5855 6.0075 6.6002 Dif. 9.2118 9.9329 4.5952 5.6572 4.3931
1.259 0.777 Máx. -0.3709 6.5723 -3.9146 -2.7269 2.9363 1.759 1.527 Máx. -5.1180 2.5747 -1.8350 -5.3594 3.0230
Mín. -7.4319 -0.4199 -15.3591 -9.2877 -2.5099 Mín. -15.1330 -7.2805 -6.4767 -10.7561 -1.5364
Dif. 7.0610 6.9922 11.4444 6.5609 5.4462 Dif. 10.0150 9.8552 4.6417 5.3968 4.5594

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 50 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY
1.759 1.777 Máx. -5.1607 -0.1978 -2.5291 -3.5997 3.6543 2.259 2.504 Máx. -9.9514 -0.9690 5.5450 0.8464 6.3345
Mín. -17.2724 -8.2614 -7.2934 -9.6279 -0.8592 Mín. -36.5042 -17.9136 -1.9672 0.0143 0.2441
Dif. 12.1117 8.0635 4.7643 6.0282 4.5135 Dif. 26.5528 16.9446 7.5123 0.8320 6.0904
1.759 2.027 Máx. -5.2429 -2.5581 -3.5807 -1.7556 3.9750 2.509 0.050 Máx. -16.7262 32.2863 14.7712 2.1437 1.6578
Mín. -20.8172 -7.5755 -8.6349 -7.1519 -0.2373 Mín. -42.3052 -2.9096 0.3049 0.2394 -5.5675
Dif. 15.5743 5.0175 5.0542 5.3963 4.2123 Dif. 25.5791 35.1959 14.4663 1.9043 7.2253
1.759 2.277 Máx. -5.4300 -1.9322 -3.8762 -0.5092 4.0294 2.509 0.277 Máx. -16.7262 29.2532 14.7712 3.2825 0.0906
Mín. -26.3846 -6.4651 -11.4400 -3.5490 0.0438 Mín. -42.3052 4.6388 0.3049 -9.6178 -5.5544
Dif. 20.9546 4.5329 7.5638 3.0398 3.9856 Dif. 25.5791 24.6145 14.4663 12.9003 5.6451
1.759 2.504 Máx. -5.4300 -1.2708 -3.8762 0.0078 3.7463 2.509 0.527 Máx. -7.4351 26.2105 11.1455 0.3858 -1.5746
Mín. -26.3846 -5.2298 -11.4400 -0.5703 -0.0353 Mín. -27.6271 8.7287 2.1045 -14.1196 -4.4715
Dif. 20.9546 3.9590 7.5638 0.5781 3.7815 Dif. 20.1920 17.4818 9.0410 14.5054 2.8968
2.009 0.050 Máx. -7.3504 9.4778 -0.3033 0.4161 -0.8577 2.509 0.777 Máx. -4.2980 22.5770 8.9028 -4.2542 -0.8083
Mín. -31.5588 1.5949 -6.1598 -0.1696 -4.9064 Mín. -16.8584 2.9602 3.2853 -16.3746 -3.8178
Dif. 24.2084 7.8829 5.8565 0.5857 4.0486 Dif. 12.5604 19.6168 5.6175 12.1203 3.0095
2.009 0.277 Máx. -7.3504 11.2340 -0.3033 -0.0825 -1.0437 2.509 1.027 Máx. -3.8496 16.6957 7.5355 -8.1758 0.4270
Mín. -31.5588 2.6082 -6.1598 -4.4183 -5.1409 Mín. -10.2182 -3.6049 3.8203 -16.7309 -2.8416
Dif. 24.2084 8.6258 5.8565 4.3359 4.0972 Dif. 6.3686 20.3006 3.7153 8.5551 3.2686
2.009 0.527 Máx. -6.0496 12.0149 -0.5972 -1.5378 -1.1141 2.509 1.277 Máx. -3.1768 9.3564 7.2817 -9.1407 1.5014
Mín. -22.3874 3.5540 -3.7374 -8.7001 -4.4430 Mín. -8.7577 -9.3305 4.0064 -17.2817 -1.5094
Dif. 16.3378 8.4609 3.1402 7.1623 3.3289 Dif. 5.5809 18.6869 3.2753 8.1410 3.0107
2.009 0.777 Máx. -5.1177 11.0110 -0.4727 -3.8023 -0.0917 2.509 1.527 Máx. -3.8465 3.6279 7.5369 -8.1821 2.8331
Mín. -16.9304 1.1577 -2.2746 -11.3641 -4.0235 Mín. -10.2141 -16.6651 3.8213 -16.7393 -0.4334
Dif. 11.8127 9.8534 1.8018 7.5619 3.9318 Dif. 6.3676 20.2930 3.7156 8.5572 3.2666
2.009 1.027 Máx. -4.4189 9.3575 -0.0917 -5.8714 1.0445 2.509 1.777 Máx. -4.2929 -2.9326 8.9044 -4.2667 3.8110
Mín. -13.8518 -2.7205 -1.5385 -12.5791 -3.2216 Mín. -16.8516 -22.5402 3.2864 -16.3912 0.8031
Dif. 9.4329 12.0780 1.4468 6.7077 4.2661 Dif. 12.5587 19.6076 5.6179 12.1245 3.0079
2.009 1.277 Máx. -4.1854 6.0210 0.1267 -6.3456 2.0510 2.509 2.027 Máx. -7.4297 -8.6863 11.1450 0.3659 4.4666
Mín. -12.8114 -6.0065 -1.2885 -13.2563 -2.0556 Mín. -27.6200 -26.1541 2.1042 -14.1461 1.5709
Dif. 8.6260 12.0275 1.4152 6.9107 4.1066 Dif. 20.1903 17.4677 9.0409 14.5120 2.8957
2.009 1.527 Máx. -4.4123 2.7317 -0.0886 -5.8771 3.2166 2.509 2.277 Máx. -16.7166 -4.7154 14.7684 3.2482 5.5496
Mín. -13.8430 -9.3426 -1.5344 -12.5866 -1.0483 Mín. -42.2927 -29.3554 0.3028 -9.6635 -0.0943
Dif. 9.4307 12.0743 1.4458 6.7095 4.2649 Dif. 25.5760 24.6400 14.4656 12.9117 5.6439
2.009 1.777 Máx. -5.1003 -1.1510 -0.4662 -3.8131 4.0192 2.509 2.504 Máx. -16.7166 2.7030 14.7684 2.1931 5.5618
Mín. -16.9073 -11.0022 -2.2658 -11.3786 0.0884 Mín. -42.2927 -32.5617 0.3028 0.2764 -1.6621
Dif. 11.8070 9.8512 1.7996 7.5655 3.9308 Dif. 25.5760 35.2647 14.4656 1.9166 7.2239
2.009 2.027 Máx. -6.0104 -3.5562 -0.5865 -1.5528 4.4411 2.759 0.050 Máx. -7.8643 54.5825 20.7616 15.2532 10.7644
Mín. -22.3352 -12.0178 -3.7231 -8.7200 1.1127 Mín. -63.8243 4.6601 4.1014 0.2295 -2.6920
Dif. 16.3248 8.4616 3.1366 7.1672 3.3285 Dif. 55.9601 49.9224 16.6602 15.0236 13.4564
2.009 2.277 Máx. -7.2710 -2.6711 -0.2881 -0.0994 5.1480 2.759 0.277 Máx. -7.8643 49.8331 20.7616 9.8850 4.1685
Mín. -31.4531 -11.3179 -6.1395 -4.4409 1.0490 Mín. -63.8243 11.8088 4.1014 -12.5349 -3.7138
Dif. 24.1821 8.6468 5.8514 4.3415 4.0990 Dif. 55.9601 38.0243 16.6602 22.4199 7.8823
2.009 2.504 Máx. -7.2710 -1.7129 -0.2881 0.4460 4.9198 2.759 0.527 Máx. -2.3917 43.1653 15.8762 1.7555 0.8900
Mín. -31.4531 -9.6352 -6.1395 -0.1472 0.8677 Mín. -28.9926 11.3909 6.3603 -16.2993 -4.6493
Dif. 24.1821 7.9223 5.8514 0.5932 4.0520 Dif. 26.6009 31.7744 9.5160 18.0549 5.5393
2.259 0.050 Máx. -10.0063 17.6376 5.5410 0.7963 -0.2410 2.759 0.777 Máx. -1.6059 32.2923 12.6473 -5.0458 0.2869
Mín. -36.5772 0.7620 -1.9703 -0.0232 -6.3303 Mín. -12.8676 2.8252 6.1423 -18.2279 -3.3451
Dif. 26.5710 16.8756 7.5112 0.8195 6.0893 Dif. 11.2617 29.4672 6.5051 13.1821 3.6320
2.259 0.277 Máx. -10.0063 18.4103 5.5410 0.7944 -0.9388 2.759 1.027 Máx. -1.7909 20.6956 10.7233 -9.3702 0.2688
Mín. -36.5772 3.3710 -1.9703 -6.4266 -6.1567 Mín. -6.3577 -4.0978 5.9803 -18.4307 -1.8280
Dif. 26.5710 15.0392 7.5112 7.2210 5.2179 Dif. 4.5668 24.7934 4.7430 9.0606 2.0968
2.259 0.527 Máx. -8.0092 18.1140 4.6062 -0.8910 -2.0439 2.759 1.277 Máx. -1.3979 10.7320 10.1871 -11.0296 0.9316
Mín. -23.2430 5.1830 -0.5795 -11.1505 -4.4606 Mín. -5.1278 -10.7015 6.0398 -19.1578 -0.9409
Dif. 15.2337 12.9310 5.1857 10.2595 2.4167 Dif. 3.7299 21.4336 4.1473 8.1282 1.8725
2.259 0.777 Máx. -5.8345 15.4767 3.9196 -3.9750 -0.7036 2.759 1.527 Máx. -1.7895 4.1234 10.7261 -9.3781 1.8184
Mín. -15.8505 2.2772 0.7075 -13.7924 -4.1429 Mín. -6.3559 -20.6616 5.9821 -18.4413 -0.2760
Dif. 10.0160 13.1994 3.2121 9.8174 3.4392 Dif. 4.5663 24.7849 4.7440 9.0632 2.0944
2.259 1.027 Máx. -4.1474 12.5364 3.4446 -6.8909 0.6648 2.759 1.777 Máx. -1.6066 -2.8010 12.6517 -5.0611 3.3381
Mín. -11.9882 -3.0578 1.5330 -14.6496 -3.2186 Mín. -12.8686 -32.2602 6.1455 -18.2482 -0.2922
Dif. 7.8408 15.5942 1.9116 7.7587 3.8834 Dif. 11.2620 29.4592 6.5062 13.1871 3.6303
2.259 1.277 Máx. -3.5388 7.5697 3.3868 -7.4959 1.8409 2.759 2.027 Máx. -2.4037 -11.3653 15.8809 1.7345 4.6458
Mín. -10.7774 -7.5492 1.8511 -15.3467 -1.8477 Mín. -29.0087 -43.1313 6.3638 -16.3273 -0.8927
Dif. 7.2386 15.1189 1.5356 7.8508 3.6886 Dif. 26.6050 31.7660 9.5172 18.0618 5.5385
2.259 1.527 Máx. -4.1415 3.0760 3.4467 -6.8965 3.2112 2.759 2.277 Máx. -7.9019 -11.8605 20.7609 9.8596 3.7114
Mín. -11.9804 -12.5122 1.5346 -14.6571 -0.6705 Mín. -63.8747 -49.9021 4.1008 -12.5688 -4.1717
Dif. 7.8388 15.5882 1.9121 7.7606 3.8816 Dif. 55.9728 38.0416 16.6601 22.4284 7.8831
2.259 1.777 Máx. -5.8198 -2.2556 3.9230 -3.9862 4.1362 2.759 2.504 Máx. -7.9019 -4.7913 20.7609 15.2836 2.6895
Mín. -15.8309 -15.4478 0.7101 -13.8073 0.6986 Mín. -63.8747 -54.7575 4.1008 0.2524 -10.7677
MOD-A4-E_Is.00

Dif. 10.0111 13.1922 3.2129 9.8211 3.4376 Dif. 55.9728 49.9662 16.6601 15.0313 13.4572
2.259 2.027 Máx. -7.9787 -5.1485 4.6097 -0.9091 4.4558 3.009 0.200 Máx. 6.3946 265.9888 29.2461 80.0785 12.4971
Mín. -23.2023 -18.0680 -0.5769 -11.1746 2.0402 Mín. -5.6072 21.3002 9.2956 -8.3908 -12.0342
Dif. 15.2236 12.9195 5.1866 10.2655 2.4156 Dif. 12.0018 244.6886 19.9505 88.4693 24.5313
2.259 2.277 Máx. -9.9514 -3.4523 5.5450 0.7620 6.1573 3.009 0.277 Máx. 6.3946 186.2701 29.2461 24.4811 6.7739
Mín. -36.5042 -18.5186 -1.9672 -6.4699 0.9392 Mín. -5.6072 17.7365 9.2956 -11.7336 -6.5958
Dif. 26.5528 15.0663 7.5123 7.2318 5.2181 Dif. 12.0018 168.5336 19.9505 36.2147 13.3697

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 51 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY
3.009 0.527 Máx. 4.5142 78.3257 20.5105 0.8546 3.5401 3.509 1.277 Máx. 9.4613 9.3688 6.9248 -9.2176 1.4976
Mín. -3.7495 10.3486 7.9474 -16.4092 -3.5209 Mín. 3.7045 -9.3212 3.7770 -17.3841 -1.5144
Dif. 8.2637 67.9771 12.5631 17.2638 7.0610 Dif. 5.7568 18.6900 3.1478 8.1666 3.0120
3.009 0.777 Máx. 1.4413 39.2042 14.8224 -6.2759 1.9336 3.509 1.527 Máx. 10.8865 3.5749 7.2216 -8.2464 0.4654
Mín. -0.7398 2.8899 6.9011 -18.7450 -1.9661 Mín. 4.3508 -16.7358 3.5848 -16.8251 -2.7905
Dif. 2.1811 36.3143 7.9213 12.4690 3.8996 Dif. 6.5356 20.3106 3.6368 8.5786 3.2559
3.009 1.027 Máx. 1.1877 22.1761 11.9078 -10.1120 0.9298 3.509 1.777 Máx. 17.4056 -2.9977 8.5517 -4.2892 -0.7307
Mín. -0.4977 -4.1448 6.6312 -19.1294 -0.9632 Mín. 4.7084 -22.6270 3.0219 -16.4212 -3.7144
Dif. 1.6854 26.3209 5.2766 9.0174 1.8930 Dif. 12.6972 19.6293 5.5298 12.1320 2.9837
3.009 1.277 Máx. 1.5398 11.0968 11.2039 -12.5953 0.1685 3.509 2.027 Máx. 27.9034 -8.6448 10.7061 0.4034 -1.4624
Mín. -0.8456 -11.0612 7.2025 -19.9358 -0.1800 Mín. 7.6423 -26.0987 1.7749 -14.0961 -4.3219
Dif. 2.3854 22.1580 4.0014 7.3405 0.3485 Dif. 20.2611 17.4539 8.9311 14.4995 2.8595
3.009 1.527 Máx. 1.1909 4.1736 11.9122 -10.1220 0.9510 3.509 2.277 Máx. 41.8871 -4.4288 14.1698 3.3307 0.2322
Mín. -0.4953 -22.1378 6.6341 -19.1427 -0.9389 Mín. 16.4125 -28.9733 -0.1462 -9.5536 -5.3657
Dif. 1.6862 26.3114 5.2781 9.0207 1.8900 Dif. 25.4746 24.5445 14.3160 12.8843 5.5979
3.009 1.777 Máx. 1.4455 -2.8688 14.8308 -6.2954 1.9565 3.509 2.504 Máx. 41.8871 3.1421 14.1698 2.1602 1.7958
Mín. -0.7366 -39.1762 6.9073 -18.7710 -1.9407 Mín. 16.4125 -31.9764 -0.1462 0.2518 -5.3835
Dif. 2.1821 36.3074 7.9235 12.4755 3.8973 Dif. 25.4746 35.1185 14.3160 1.9084 7.1793
3.009 2.027 Máx. 4.5160 -10.3532 20.5254 0.8277 3.5171 3.759 0.050 Máx. 35.5071 17.6440 5.1277 0.8040 6.0752
Mín. -3.7482 -78.3320 7.9585 -16.4451 -3.5452 Mín. 9.2037 0.7668 -2.2802 -0.0174 0.0496
Dif. 8.2641 67.9788 12.5669 17.2728 7.0623 Dif. 26.3034 16.8772 7.4079 0.8214 6.0256
3.009 2.277 Máx. 6.3922 -17.8260 29.2714 24.4510 6.5969 3.759 0.277 Máx. 35.5071 18.5425 5.1277 0.8107 5.9013
Mín. -5.6089 -186.3900 9.3145 -11.7562 -6.7723 Mín. 9.2037 3.4703 -2.2802 -6.4049 0.7472
Dif. 12.0011 168.5640 19.9569 36.2072 13.3692 Dif. 26.3034 15.0722 7.4079 7.2156 5.1541
3.009 2.354 Máx. 6.3922 -21.4549 29.2714 80.0905 12.0412 3.759 0.527 Máx. 23.0806 18.4094 4.1991 -0.9096 4.2497
Mín. -5.6089 -266.1958 9.3145 -8.3820 -12.4876 Mín. 7.8875 5.4046 -0.8849 -11.1753 1.8857
Dif. 12.0011 244.7409 19.9569 88.4725 24.5288 Dif. 15.1931 13.0048 5.0839 10.2657 2.3640
3.259 0.050 Máx. 64.2017 53.3215 20.2177 15.1119 2.8650 3.759 0.777 Máx. 16.1618 15.7698 3.5162 -4.0534 3.9975
Mín. 8.1472 3.7145 3.6935 0.1237 -10.5336 Mín. 6.0680 2.4972 0.4050 -13.8968 0.5946
Dif. 56.0544 49.6070 16.5242 14.9883 13.3986 Dif. 10.0938 13.2727 3.1112 9.8435 3.4029
3.259 0.277 Máx. 64.2017 49.0437 20.2177 10.0274 3.7466 3.759 1.027 Máx. 12.5242 12.7153 3.0371 -7.0139 3.1400
Mín. 8.1472 11.2169 3.6935 -12.3450 -4.1247 Mín. 4.5494 -2.9236 1.2274 -14.8135 -0.7238
Dif. 56.0544 37.8269 16.5242 22.3724 7.8714 Dif. 7.9748 15.6389 1.8097 7.7997 3.8638
3.259 0.527 Máx. 29.6672 43.0009 15.5597 1.8313 4.6031 3.759 1.277 Máx. 11.3839 7.5893 2.9078 -7.6366 1.8359
Mín. 2.8975 11.2677 6.1229 -16.1982 -0.9247 Mín. 3.9937 -7.5345 1.5432 -15.5344 -1.8544
Dif. 26.7696 31.7333 9.4368 18.0296 5.5278 Dif. 7.3902 15.1238 1.3645 7.8978 3.6903
3.259 0.777 Máx. 13.5918 32.3129 12.4295 -5.0280 3.2791 3.759 1.527 Máx. 12.5336 2.9699 3.0387 -7.0266 0.7081
Mín. 2.1490 2.8406 5.9789 -18.2041 -0.3365 Mín. 4.5565 -12.6537 1.2286 -14.8305 -3.1609
Dif. 11.4428 29.4723 6.4506 13.1761 3.6155 Dif. 7.9771 15.6236 1.8101 7.8039 3.8690
3.259 1.027 Máx. 7.1121 20.7361 10.5165 -9.3876 1.7791 3.759 1.777 Máx. 16.1810 -2.4529 3.5200 -4.0790 -0.6097
Mín. 2.3567 -4.0674 5.8474 -18.4539 -0.3055 Mín. 6.0824 -15.7110 0.4079 -13.9310 -4.0177
Dif. 4.7554 24.8035 4.6691 9.0664 2.0846 Dif. 10.0987 13.2580 3.1122 9.8520 3.4079
3.259 1.277 Máx. 5.8981 10.7380 9.9934 -11.0596 0.9295 3.759 2.027 Máx. 23.1099 -5.3635 4.2066 -0.9483 -1.8993
Mín. 1.9756 -10.6970 5.9153 -19.1978 -0.9437 Mín. 7.9094 -18.3546 -0.8792 -11.2270 -4.2679
Dif. 3.9225 21.4350 4.0781 8.1382 1.8732 Dif. 15.2005 12.9912 5.0858 10.2786 2.3686
3.259 1.527 Máx. 7.1183 4.1006 10.5213 -9.3989 0.2937 3.759 2.277 Máx. 35.5481 -3.5823 5.1415 0.7582 -0.7582
Mín. 2.3613 -20.6919 5.8505 -18.4690 -1.7948 Mín. 9.2343 -18.6919 -2.2699 -6.4749 -5.9160
Dif. 4.7569 24.7925 4.6709 9.0701 2.0885 Dif. 26.3138 15.1096 7.4114 7.2331 5.1578
3.259 1.777 Máx. 13.6059 -2.8136 12.4385 -5.0499 0.3262 3.759 2.504 Máx. 35.5481 -1.0301 5.1415 0.8542 -0.0582
Mín. 2.1596 -32.2770 5.9856 -18.2333 -3.2928 Mín. 9.2343 -17.9952 -2.2699 0.0202 -6.0867
Dif. 11.4463 29.4634 6.4529 13.1834 3.6189 Dif. 26.3138 16.9650 7.4114 0.8340 6.0285
3.259 2.027 Máx. 29.6971 -11.2504 15.5742 1.8008 0.9174 4.009 0.050 Máx. 28.2307 10.2534 -0.3814 0.5469 4.8021
Mín. 2.9200 -42.9781 6.1337 -16.2389 -4.6129 Mín. 4.8543 2.1766 -6.2639 -0.0715 0.7795
Dif. 26.7771 31.7277 9.4405 18.0397 5.5302 Dif. 23.3764 8.0768 5.8825 0.6184 4.0226
3.259 2.277 Máx. 64.2721 -11.3032 20.2366 9.9909 4.1246 4.009 0.277 Máx. 28.2307 12.1486 -0.3814 -0.1031 5.0060
Mín. 8.2000 -49.1590 3.7076 -12.3936 -3.7467 Mín. 4.8543 3.2942 -6.2639 -4.4458 0.9425
Dif. 56.0722 37.8558 16.5290 22.3846 7.8714 Dif. 23.3764 8.8544 5.8825 4.3428 4.0635
3.259 2.504 Máx. 64.2721 -3.8989 20.2366 15.1479 10.5442 4.009 0.527 Máx. 20.1500 12.9082 -0.8047 -1.6247 4.2943
Mín. 8.2000 -53.5675 3.7076 0.1506 -2.8571 Mín. 4.3716 4.2240 -4.0140 -8.8159 1.0026
Dif. 56.0722 49.6687 16.5290 14.9973 13.4013 Dif. 15.7784 8.6842 3.2094 7.1912 3.2917
3.509 0.050 Máx. 41.8373 31.6409 14.1530 2.1103 5.3811 4.009 0.777 Máx. 15.2389 11.5888 -0.7706 -3.9530 3.9175
Mín. 16.3753 -3.3936 -0.1587 0.2144 -1.7976 Mín. 3.8491 1.5910 -2.6718 -11.5651 0.0122
Dif. 25.4620 35.0345 14.3117 1.8959 7.1787 Dif. 11.3898 9.9978 1.9012 7.6121 3.9053
3.509 0.277 Máx. 41.8373 28.8282 14.1530 3.3789 5.3581 4.009 1.027 Máx. 12.4005 9.6451 -0.4437 -6.0589 3.1638
Mín. 16.3753 4.3201 -0.1587 -9.4893 -0.2379 Mín. 3.3304 -2.5048 -2.0078 -12.8291 -1.0878
Dif. 25.4620 24.5081 14.3117 12.8682 5.5960 Dif. 9.0701 12.1499 1.5641 6.7702 4.2517
3.509 0.527 Máx. 27.8714 26.1444 10.6948 0.4387 4.3078 4.009 1.277 Máx. 11.4316 6.0477 -0.2443 -6.5468 2.0449
Mín. 7.6184 8.6792 1.7666 -14.0491 1.4518 Mín. 3.1506 -5.9865 -1.7833 -13.5246 -2.0638
MOD-A4-E_Is.00

Dif. 20.2530 17.4653 8.9283 14.4878 2.8560 Dif. 8.2810 12.0342 1.5389 6.9777 4.1087
3.509 0.777 Máx. 17.3869 22.6755 8.5447 -4.2653 3.6971 4.009 1.527 Máx. 12.4094 2.5570 -0.4442 -6.0718 1.0716
Mín. 4.6944 3.0341 3.0167 -16.3893 0.7177 Mín. 3.3371 -9.5756 -2.0085 -12.8462 -3.1856
Dif. 12.6925 19.6413 5.5280 12.1240 2.9794 Dif. 9.0723 12.1326 1.5643 6.7744 4.2571
3.509 1.027 Máx. 10.8779 16.7884 7.2183 -8.2343 2.7717 4.009 1.777 Máx. 15.2579 -1.5403 -0.7708 -3.9792 -0.0287
Mín. 4.3444 -3.5353 3.5824 -16.8088 -0.4795 Mín. 3.8633 -11.5212 -2.6720 -11.6000 -3.9396
Dif. 6.5335 20.3237 3.6359 8.5746 3.2512 Dif. 11.3946 9.9809 1.9011 7.6208 3.9108

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 52 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY
4.009 2.027 Máx. 20.1806 -4.1778 -0.8029 -1.6648 -1.0189 4.759 0.050 Máx. 9.3481 5.4423 -3.2121 0.3987 3.2887
Mín. 4.3945 -12.8466 -4.0117 -8.8694 -4.3161 Mín. -3.7128 1.0272 -16.1971 -0.1355 -3.5270
Dif. 15.7861 8.6688 3.2088 7.2046 3.2972 Dif. 13.0608 4.4152 12.9850 0.5342 6.8157
4.009 2.277 Máx. 28.2778 -3.4051 -0.3756 -0.1571 -0.9577 4.759 0.277 Máx. 9.3481 5.9013 -3.2121 0.0614 3.5782
Mín. 4.8896 -12.2965 -6.2561 -4.5178 -5.0263 Mín. -3.7128 2.6345 -16.1971 -3.2726 -3.7498
Dif. 23.3882 8.8914 5.8805 4.3608 4.0686 Dif. 13.0608 3.2668 12.9850 3.3341 7.3280
4.009 2.504 Máx. 28.2778 -2.4415 -0.3756 0.5967 -0.7925 4.759 0.527 Máx. 6.9247 7.0604 -2.3646 -1.0512 3.2263
Mín. 4.8896 -10.6067 -6.2561 -0.0342 -4.8195 Mín. -2.2069 2.6440 -14.2148 -7.0222 -3.2909
Dif. 23.3882 8.1651 5.8805 0.6309 4.0270 Dif. 9.1316 4.4164 11.8501 5.9711 6.5172
4.259 0.050 Máx. 21.0291 6.6491 -3.0559 0.4622 3.8970 4.759 0.777 Máx. 5.4222 7.2457 -1.7612 -2.7512 2.6722
Mín. 1.4135 2.3353 -10.3463 -0.0755 0.0778 Mín. -1.1364 0.0852 -12.4879 -9.3202 -2.7199
Dif. 19.6156 4.3138 7.2904 0.5377 3.8192 Dif. 6.5586 7.1605 10.7266 6.5690 5.3921
4.259 0.277 Máx. 21.0291 8.2881 -3.0559 -0.3759 4.1331 4.759 1.027 Máx. 4.5515 6.4453 -1.4290 -4.7285 2.2549
Mín. 1.4135 3.2995 -10.3463 -3.3712 0.1216 Mín. -0.4592 -2.4734 -11.2851 -9.9785 -2.2893
Dif. 19.6156 4.9886 7.2904 2.9953 4.0115 Dif. 5.0107 8.9187 9.8562 5.2500 4.5442
4.259 0.527 Máx. 15.8525 9.2530 -3.0319 -1.8500 3.9977 4.759 1.277 Máx. 4.2378 4.5819 -1.3732 -6.0303 2.1111
Mín. 1.5195 3.8162 -7.9032 -7.2777 -0.2202 Mín. -0.1981 -4.5200 -10.8087 -10.3396 -2.1204
Dif. 14.3330 5.4368 4.8712 5.4278 4.2179 Dif. 4.4360 9.1019 9.4354 4.3094 4.2315
4.259 0.777 Máx. 12.5549 9.1073 -2.1477 -3.7763 3.6563 4.759 1.527 Máx. 4.5472 2.5283 -1.4347 -4.7372 2.2780
Mín. 1.6226 0.8323 -6.7848 -9.8633 -0.8577 Mín. -0.4625 -6.3721 -11.2927 -9.9900 -2.2633
Dif. 10.9323 8.2750 4.6371 6.0870 4.5140 Dif. 5.0096 8.9004 9.8581 5.2529 4.5413
4.259 1.027 Máx. 10.5221 7.6617 -1.5431 -5.5709 3.0187 4.759 1.777 Máx. 5.4139 -0.0216 -1.7736 -2.7688 2.7064
Mín. 1.6599 -2.2888 -6.0875 -11.0382 -1.5396 Mín. -1.1426 -7.1610 -12.5043 -9.3436 -2.6823
Dif. 8.8622 9.9505 4.5444 5.4673 4.5583 Dif. 6.5565 7.1394 10.7307 6.5748 5.3887
4.259 1.277 Máx. 9.7787 5.0031 -1.3375 -5.9599 2.1890 4.759 2.027 Máx. 6.9162 -2.5512 -2.3859 -1.0797 3.2729
Mín. 1.7126 -4.9378 -5.8446 -11.6927 -2.2064 Mín. -2.2132 -6.9366 -14.2432 -7.0603 -3.2397
Dif. 8.0661 9.9410 4.5071 5.7328 4.3954 Dif. 9.1294 4.3855 11.8572 5.9806 6.5126
4.259 1.527 Máx. 10.5290 2.3453 -1.5457 -5.5830 1.5241 4.759 2.277 Máx. 9.3585 -2.6854 -3.2462 0.0092 3.7248
Mín. 1.6650 -7.5864 -6.0910 -11.0543 -3.0393 Mín. -3.7050 -5.9692 -16.2426 -3.3423 -3.5969
Dif. 8.8639 9.9317 4.5453 5.4713 4.5635 Dif. 13.0634 3.2838 12.9964 3.3515 7.3217
4.259 1.777 Máx. 12.5718 -0.7752 -2.1522 -3.8014 0.8411 4.759 2.504 Máx. 9.3585 -1.2444 -3.2462 0.4329 3.5002
Mín. 1.6353 -9.0312 -6.7908 -9.8968 -3.6785 Mín. -3.7050 -5.7320 -16.2426 -0.1098 -3.3088
Dif. 10.9365 8.2560 4.6386 6.0954 4.5196 Dif. 13.0634 4.4876 12.9964 0.5428 6.8090
4.259 2.027 Máx. 15.8863 -3.7621 -3.0363 -1.8895 0.2021 5.009 0.050 Máx. 5.6389 7.6167 -2.0078 0.0594 3.5411
Mín. 1.5448 -9.1809 -7.9090 -7.3305 -4.0218 Mín. -6.9168 -1.3136 -18.0754 -0.6062 -6.0427
Dif. 14.3415 5.4188 4.8727 5.4409 4.2239 Dif. 12.5557 8.9304 16.0675 0.6657 9.5838
4.259 2.277 Máx. 21.0902 -3.4054 -3.0573 -0.4300 -0.1398 5.009 0.277 Máx. 5.6389 7.5787 -2.0078 0.6180 3.6723
Mín. 1.4593 -8.4293 -10.3480 -3.4434 -4.1574 Mín. -6.9168 0.3723 -18.0754 -4.4789 -6.1912
Dif. 19.6309 5.0240 7.2908 3.0134 4.0176 Dif. 12.5557 7.2064 16.0675 5.0968 9.8634
4.259 2.504 Máx. 21.0902 -2.5982 -3.0573 0.5116 -0.0938 5.009 0.527 Máx. 3.8770 7.2774 -1.4044 -0.0447 2.8862
Mín. 1.4593 -6.9997 -10.3480 -0.0384 -3.9184 Mín. -2.1419 2.0989 -15.7412 -8.3406 -4.9986
Dif. 19.6309 4.4014 7.2908 0.5501 3.8246 Dif. 6.0189 5.1785 14.3368 8.2959 7.8848
4.509 0.050 Máx. 14.2137 5.0168 -4.0997 0.4314 3.4421 5.009 0.777 Máx. 3.2745 7.6017 -1.1107 -1.9469 2.0349
Mín. -1.7467 2.1513 -13.5305 -0.0843 -1.4565 Mín. -0.1452 0.1179 -13.6680 -10.5260 -3.6099
Dif. 15.9603 2.8655 9.4308 0.5157 4.8986 Dif. 3.4198 7.4839 12.5573 8.5791 5.6448
4.509 0.277 Máx. 14.2137 6.1803 -4.0997 -0.2797 3.8193 5.009 1.027 Máx. 3.0813 7.1605 -1.0150 -4.4107 1.6024
Mín. -1.7467 3.4756 -13.5305 -3.0081 -1.6723 Mín. 0.8349 -2.8897 -12.1996 -10.8172 -2.4542
Dif. 15.9603 2.7047 9.4308 2.7284 5.4916 Dif. 2.2463 10.0502 11.1846 6.4065 4.0566
4.509 0.527 Máx. 10.8820 7.8406 -3.1245 -1.6152 3.6746 5.009 1.277 Máx. 3.0614 5.3906 -1.0710 -6.5205 1.7022
Mín. -0.9856 2.9316 -11.7676 -6.7046 -1.7444 Mín. 1.1231 -5.3349 -11.5987 -10.7290 -1.7065
Dif. 11.8676 4.9090 8.6431 5.0894 5.4191 Dif. 1.9384 10.7255 10.5278 4.2085 3.4087
4.509 0.777 Máx. 8.6904 7.6982 -2.3411 -3.3478 3.2508 5.009 1.527 Máx. 3.0718 2.9381 -1.0199 -4.4187 2.4490
Mín. -0.4295 0.3829 -10.3308 -9.1208 -1.8185 Mín. 0.8278 -7.0959 -12.2062 -10.8278 -1.6063
Dif. 9.1199 7.3153 7.9896 5.7730 5.0694 Dif. 2.2440 10.0340 11.1863 6.4091 4.0553
4.509 1.027 Máx. 7.3006 6.5817 -1.8417 -5.1809 2.7337 5.009 1.777 Máx. 3.2511 -0.0666 -1.1212 -1.9627 3.6036
Mín. -0.0494 -2.2315 -9.3773 -10.0194 -1.9795 Mín. -0.1628 -7.5334 -13.6821 -10.5471 -2.0396
Dif. 7.3500 8.8132 7.5357 4.8384 4.7132 Dif. 3.4139 7.4668 12.5609 8.5844 5.6432
4.509 1.277 Máx. 6.7695 4.4854 -1.6905 -5.8132 2.2412 5.009 2.027 Máx. 3.8282 -2.0415 -1.4218 -0.0687 4.9893
Mín. 0.1345 -4.4197 -9.0260 -10.6417 -2.2554 Mín. -2.1907 -7.2009 -15.7644 -8.3726 -2.8931
Dif. 6.6350 8.9051 7.3355 4.8285 4.4966 Dif. 6.0189 5.1594 14.3426 8.3039 7.8824
4.509 1.527 Máx. 7.3028 2.2895 -1.8464 -5.1914 1.9668 5.009 2.277 Máx. 5.5699 -0.3840 -2.0326 0.5850 6.1727
Mín. -0.0477 -6.5044 -9.3836 -10.0333 -2.7508 Mín. -7.0088 -7.5943 -18.1084 -4.5228 -3.6861
Dif. 7.3505 8.7939 7.5373 4.8419 4.7175 Dif. 12.5786 7.2103 16.0758 5.1078 9.8588
4.509 1.777 Máx. 8.6991 -0.3197 -2.3505 -3.3698 1.8038 5.009 2.504 Máx. 5.5699 1.2290 -2.0326 0.0597 6.0192
Mín. -0.4229 -7.6140 -10.3432 -9.1501 -3.2705 Mín. -7.0088 -7.7296 -18.1084 -0.6059 -3.5587
Dif. 9.1221 7.2943 7.9927 5.7803 5.0743 Dif. 12.5786 8.9586 16.0758 0.6656 9.5779
4.509 2.027 Máx. 10.9117 -2.8627 -3.1376 -1.6515 1.7265 5.259 0.050 Máx. 0.0291 15.6182 0.0429 0.1913 4.1888
Mín. -0.9633 -7.7488 -11.7850 -6.7529 -3.6985 Mín. -13.9556 -4.2865 -18.6023 -0.5641 -8.2822
MOD-A4-E_Is.00

Dif. 11.8751 4.8861 8.6475 5.1015 5.4251 Dif. 13.9847 19.9048 18.6452 0.7554 12.4710
4.509 2.277 Máx. 14.3021 -3.5684 -4.1123 -0.3334 1.6525 5.259 0.277 Máx. 0.0291 13.7887 0.0429 1.9587 3.9267
Mín. -1.6804 -6.3040 -13.5472 -3.0797 -3.8457 Mín. -13.9556 -1.7596 -18.6023 -6.8320 -8.2033
Dif. 15.9825 2.7356 9.4349 2.7463 5.4982 Dif. 13.9847 15.5482 18.6452 8.7906 12.1299
4.509 2.504 Máx. 14.3021 -2.4079 -4.1123 0.4797 1.4384 5.259 0.527 Máx. -1.4210 10.0104 -0.3761 1.6244 2.2677
Mín. -1.6804 -5.3590 -13.5472 -0.0481 -3.4663 Mín. -4.8315 2.1696 -16.1947 -10.9609 -6.1765
Dif. 15.9825 2.9510 9.4349 0.5278 4.9047 Dif. 3.4105 7.8408 15.8186 12.5854 8.4441

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 53 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY
5.259 0.777 Máx. 1.5258 9.4722 -0.7073 -0.9127 1.0104 5.759 0.277 Máx. -0.8442 35.2294 4.3806 12.2100 5.3528
Mín. -3.6099 0.3419 -13.7822 -12.7849 -4.0330 Mín. -44.9425 4.0278 -13.2559 -15.8816 -6.1885
Dif. 5.1357 9.1303 13.0749 11.8722 5.0435 Dif. 44.0984 31.2015 17.6364 28.0916 11.5413
5.259 1.027 Máx. 1.7025 9.4594 -0.9344 -4.2761 0.6109 5.759 0.527 Máx. 3.1914 27.2237 1.1267 8.4578 0.6988
Mín. -1.5330 -4.0305 -12.0622 -12.4903 -2.2612 Mín. -28.5108 7.9159 -9.5832 -18.3853 -5.9212
Dif. 3.2354 13.4899 11.1277 8.2142 2.8721 Dif. 31.7022 19.3078 10.7099 26.8431 6.6199
5.259 1.277 Máx. 1.4371 7.2763 -1.1034 -7.1538 0.9874 5.759 0.777 Máx. 1.4637 26.9520 0.0768 1.1337 -0.0227
Mín. -0.4388 -7.2278 -11.3625 -11.8077 -0.9880 Mín. -16.3294 -1.7878 -6.7351 -18.6940 -5.0050
Dif. 1.8760 14.5041 10.2591 4.6539 1.9755 Dif. 17.7931 28.7398 6.8119 19.8277 4.9823
5.259 1.527 Máx. 1.6920 4.0709 -0.9375 -4.2841 2.2605 5.759 1.027 Máx. -0.3517 21.2095 -0.2847 -5.2298 -0.0643
Mín. -1.5435 -9.4055 -12.0663 -12.5009 -0.6115 Mín. -9.2690 -8.3555 -5.2340 -17.3027 -2.7837
Dif. 3.2354 13.4764 11.1288 8.2169 2.8719 Dif. 8.9174 29.5650 4.9493 12.0729 2.7194
5.259 1.777 Máx. 1.5072 -0.3062 -0.7136 -0.9279 4.0318 5.759 1.277 Máx. -0.4349 13.9925 -0.4275 -8.1982 0.7037
Mín. -3.6347 -9.4247 -13.7906 -12.8052 -1.0113 Mín. -7.6071 -13.9551 -4.7278 -16.0088 -0.7016
Dif. 5.1419 9.1184 13.0770 11.8773 5.0431 Dif. 7.1722 27.9476 4.3003 7.8106 1.4054
5.259 2.027 Máx. -1.4557 -2.1472 -0.3857 1.6042 6.1733 5.759 1.527 Máx. -0.3539 8.3852 -0.2850 -5.2379 2.7861
Mín. -4.8777 -9.9805 -16.2074 -10.9878 -2.2700 Mín. -9.2720 -21.1699 -5.2344 -17.3134 0.0661
Dif. 3.4220 7.8333 15.8218 12.5921 8.4433 Dif. 8.9181 29.5551 4.9494 12.0755 2.7200
5.259 2.277 Máx. -0.0238 1.7484 0.0292 1.9408 8.1942 5.759 1.777 Máx. 1.4597 1.8103 0.0763 1.1188 5.0077
Mín. -14.0261 -13.8034 -18.6205 -6.8558 -3.9334 Mín. -16.3348 -26.9220 -6.7358 -18.7138 0.0247
Dif. 14.0022 15.5519 18.6498 8.7966 12.1276 Dif. 17.7945 28.7323 6.8121 19.8326 4.9829
5.259 2.504 Máx. -0.0238 4.2517 0.0292 0.1895 8.2700 5.759 2.027 Máx. 3.1862 -7.9062 1.1255 8.4393 5.9251
Mín. -14.0261 -15.6646 -18.6205 -0.5665 -4.1979 Mín. -28.5178 -27.2108 -9.5848 -18.4099 -0.6958
Dif. 14.0022 19.9163 18.6498 0.7560 12.4680 Dif. 31.7040 19.3046 10.7103 26.8492 6.6209
5.509 0.050 Máx. -11.6561 30.4320 3.1349 0.8534 5.3619 5.759 2.277 Máx. -0.8498 -4.0381 4.3764 12.1943 6.1962
Mín. -20.0678 -11.1224 -16.9858 -0.3775 -8.9835 Mín. -44.9502 -35.2429 -13.2615 -15.9025 -5.3470
Dif. 8.4117 41.5544 20.1208 1.2309 14.3454 Dif. 44.1003 31.2048 17.6379 28.0968 11.5432
5.509 0.277 Máx. -11.6561 24.1187 3.1349 5.1808 4.4296 5.759 2.504 Máx. -0.8498 10.3838 4.3764 8.2052 4.3623
Mín. -20.0678 -4.3335 -16.9858 -10.7586 -8.7765 Mín. -44.9502 -49.7604 -13.2615 -1.3435 -7.0042
Dif. 8.4117 28.4522 20.1208 15.9393 13.2062 Dif. 44.1003 60.1441 17.6379 9.5488 11.3665
5.509 0.527 Máx. -0.3950 14.2147 0.9716 4.4345 1.2325 5.968 0.277 Máx. 8.4632 35.2294 6.0238 12.2100 9.1418
Mín. -16.5798 4.7306 -14.2213 -14.6720 -6.2531 Mín. -62.4304 4.0278 -0.5791 -15.8816 -6.4211
Dif. 16.1848 9.4841 15.1928 19.1065 7.4855 Dif. 70.8936 31.2015 6.6029 28.0916 15.5628
5.509 0.777 Máx. 1.2806 14.6558 -0.0899 0.2685 -0.4110 5.968 0.527 Máx. 5.1516 27.2237 0.6958 8.4578 1.2004
Mín. -11.3517 0.0416 -11.4319 -15.7602 -3.8138 Mín. -33.7095 7.9159 -0.3938 -18.3853 -6.0828
Dif. 12.6323 14.6142 11.3420 16.0287 3.4029 Dif. 38.8612 19.3078 1.0896 26.8431 7.2832
5.509 1.027 Máx. 0.2187 13.9879 -0.5749 -4.4689 -0.3303 5.968 0.777 Máx. 1.3757 26.9520 0.0371 1.1337 0.1740
Mín. -6.4280 -6.0418 -9.6037 -14.7798 -2.0278 Mín. -17.5718 -1.7878 -0.5399 -18.6940 -5.1244
Dif. 6.6467 20.0297 9.0287 10.3109 1.6976 Dif. 18.9475 28.7398 0.5770 19.8277 5.2984
5.509 1.277 Máx. 0.1710 10.2725 -0.7982 -7.7581 0.3679 5.968 1.027 Máx. -0.5020 21.2095 -0.0697 -5.2298 0.0125
Mín. -5.1275 -10.2305 -8.9047 -13.5309 -0.3665 Mín. -9.9688 -8.3555 -0.6066 -17.3027 -2.7872
Dif. 5.2985 20.5030 8.1065 5.7727 0.7344 Dif. 9.4668 29.5650 0.5369 12.0729 2.7998
5.509 1.527 Máx. 0.2131 6.0755 -0.5762 -4.4768 2.0295 5.968 1.277 Máx. -0.6486 13.9925 -0.0969 -8.1982 0.9408
Mín. -6.4355 -13.9430 -9.6054 -14.7904 0.3315 Mín. -8.1892 -13.9551 -0.6114 -16.0088 -0.9389
Dif. 6.6486 20.0185 9.0292 10.3136 1.6980 Dif. 7.5406 27.9476 0.5145 7.8106 1.8798
5.509 1.777 Máx. 1.2686 -0.0158 -0.0924 0.2538 3.8154 5.968 1.527 Máx. -0.5026 8.3852 -0.0697 -5.2379 2.7894
Mín. -11.3677 -14.6214 -11.4354 -15.7798 0.4122 Mín. -9.9696 -21.1699 -0.6066 -17.3134 -0.0109
Dif. 12.6363 14.6056 11.3429 16.0336 3.4032 Dif. 9.4670 29.5551 0.5369 12.0755 2.8003
5.509 2.027 Máx. -0.4139 -4.7202 0.9672 4.4168 6.2541 5.968 1.777 Máx. 1.3752 1.8103 0.0369 1.1188 5.1269
Mín. -16.6050 -14.2008 -14.2271 -14.6956 -1.2317 Mín. -17.5725 -26.9220 -0.5401 -18.7138 -0.1721
Dif. 16.1911 9.4806 15.1943 19.1123 7.4857 Dif. 18.9477 28.7323 0.5771 19.8326 5.2990
5.509 2.277 Máx. -11.6794 4.3225 3.1260 5.1676 8.7766 5.968 2.027 Máx. 5.1523 -7.9062 0.6949 8.4393 6.0872
Mín. -20.0988 -24.1332 -16.9978 -10.7761 -4.4296 Mín. -33.7088 -27.2108 -0.3944 -18.4099 -1.1971
Dif. 8.4194 28.4557 20.1238 15.9437 13.2062 Dif. 38.8611 19.3046 1.0894 26.8492 7.2843
5.509 2.504 Máx. -11.6794 11.0999 3.1260 0.8509 8.9831 5.968 2.277 Máx. 8.4665 -4.0381 6.0188 12.1943 6.4297
Mín. -20.0988 -30.4619 -16.9978 -0.3794 -5.3621 Mín. -62.4262 -35.2429 -0.5828 -15.9025 -9.1302
Dif. 8.4194 41.5617 20.1238 1.2303 14.3453 Dif. 70.8927 31.2048 6.6016 28.0968 15.5600
5.759 0.050 Máx. -0.8442 49.7309 4.3806 8.2123 7.0136
Mín. -44.9425 -10.4060 -13.2559 -1.3382 -4.3552
Dif. 44.0984 60.1369 17.6364 9.5505 11.3688
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 54 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.11.1.2 ESQUEMAS DE ESFUERZOS

E.L.S. Cuasipermanente. Hormigón

CORTANTE X

CORTANTE Y
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 55 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

CORTANTE TOTAL

El Cortante máximo obtenido según las gráficas es de 141,49 kN/m.

MOMENTO X
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 56 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

MOMENTO Y

MOMENTO XY

El Momento máximo obtenido según las gráficas es de 35,21 kNm/m.


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 57 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.11.2 DESPLAZAMIENTOS EN NUDOS DE LA LOSA

El asiento máximo obtenido en el cálculo es de 12,78 mm.

12.11.2.1 TABLA DE DESPLAZAMIENTOS

Desp en mm. Giros en radianes x 1000

Cimentación
Coord. X Coord. Y Desp. Z Giro X Giro Y Coord. X Coord. Y Desp. Z Giro X Giro Y
0.050 0.277 Máx. -6.0019 2.3663 0.5654 0.259 1.777 Máx. -6.8044 1.9746 0.5510
Mín. -10.8982 -2.0832 -0.5792 Mín. -9.9437 -2.2038 -0.4868
Dif. 4.8962 4.4495 1.1446 Dif. 3.1393 4.1785 1.0378
0.050 0.527 Máx. -6.4963 2.2983 0.5438 0.259 2.027 Máx. -6.5005 1.9798 0.5469
Mín. -10.3132 -1.9774 -0.5444 Mín. -10.3181 -2.2796 -0.5175
Dif. 3.8169 4.2757 1.0882 Dif. 3.8176 4.2594 1.0644
0.050 0.777 Máx. -6.6876 2.2142 0.5465 0.259 2.277 Máx. -6.0039 2.0163 0.5518
Mín. -10.0448 -1.9606 -0.5052 Mín. -10.8991 -2.3453 -0.5463
Dif. 3.3571 4.1748 1.0516 Dif. 4.8952 4.3616 1.0981
0.050 1.027 Máx. -6.6702 2.1256 0.5511 0.259 2.504 Máx. -5.5441 2.0617 0.5974
Mín. -10.0118 -1.9914 -0.4790 Mín. -11.4438 -2.3911 -0.5571
Dif. 3.3416 4.1170 1.0301 Dif. 5.8997 4.4528 1.1545
0.050 1.277 Máx. -6.6657 2.0427 0.5524 0.509 0.050 Máx. -5.5508 2.3282 0.5373
Mín. -9.9999 -2.0497 -0.4694 Mín. -11.4124 -2.0108 -0.5153
Dif. 3.3342 4.0925 1.0218 Dif. 5.8616 4.3390 1.0526
0.050 1.527 Máx. -6.6719 1.9844 0.5511 0.509 0.277 Máx. -6.0064 2.2955 0.5430
Mín. -10.0135 -2.1326 -0.4789 Mín. -10.8836 -2.0012 -0.4908
Dif. 3.3416 4.1170 1.0301 Dif. 4.8772 4.2967 1.0338
0.050 1.777 Máx. -6.6911 1.9536 0.5466 0.509 0.527 Máx. -6.5044 2.2429 0.5512
Mín. -10.0483 -2.2212 -0.5051 Mín. -10.3141 -1.9890 -0.4683
Dif. 3.3571 4.1748 1.0516 Dif. 3.8097 4.2319 1.0195
0.050 2.027 Máx. -6.5015 1.9703 0.5439 0.509 0.777 Máx. -6.9384 2.1786 0.5599
Mín. -10.3184 -2.3054 -0.5443 Mín. -9.8224 -1.9920 -0.4465
Dif. 3.8169 4.2757 1.0882 Dif. 2.8840 4.1706 1.0064
0.050 2.277 Máx. -6.0090 2.0760 0.5654 0.509 1.027 Máx. -6.9244 2.1117 0.5659
Mín. -10.9052 -2.3735 -0.5791 Mín. -9.7994 -2.0156 -0.4309
Dif. 4.8962 4.4495 1.1446 Dif. 2.8751 4.1273 0.9968
0.259 0.050 Máx. -5.5354 2.3840 0.5973 0.509 1.277 Máx. -6.9214 2.0502 0.5678
Mín. -11.4351 -2.0688 -0.5572 Mín. -9.7907 -2.0573 -0.4251
Dif. 5.8997 4.4528 1.1545 Dif. 2.8693 4.1075 0.9929
0.259 0.277 Máx. -5.9968 2.3382 0.5517 0.509 1.527 Máx. -6.9261 2.0085 0.5660
Mín. -10.8920 -2.0234 -0.5464 Mín. -9.8012 -2.1187 -0.4308
Dif. 4.8952 4.3616 1.0981 Dif. 2.8751 4.1273 0.9968
0.259 0.527 Máx. -6.4952 2.2725 0.5468 0.509 1.777 Máx. -6.9420 1.9849 0.5600
Mín. -10.3128 -1.9868 -0.5176 Mín. -9.8259 -2.1856 -0.4464
Dif. 3.8176 4.2594 1.0644 Dif. 2.8839 4.1706 1.0064
0.259 0.777 Máx. -6.8008 2.1968 0.5509 0.509 2.027 Máx. -6.5097 1.9819 0.5513
Mín. -9.9402 -1.9817 -0.4868 Mín. -10.3194 -2.2500 -0.4682
Dif. 3.1393 4.1785 1.0378 Dif. 3.8097 4.2319 1.0195
0.259 1.027 Máx. -6.7850 2.1194 0.5555 0.509 2.277 Máx. -6.0135 1.9941 0.5431
Mín. -9.9124 -2.0072 -0.4653 Mín. -10.8907 -2.3026 -0.4907
Dif. 3.1274 4.1266 1.0207 Dif. 4.8772 4.2967 1.0338
0.259 1.277 Máx. -6.7813 2.0485 0.5568 0.509 2.504 Máx. -5.5595 2.0037 0.5375
MOD-A4-E_Is.00

Mín. -9.9021 -2.0555 -0.4572 Mín. -11.4211 -2.3353 -0.5152


Dif. 3.1208 4.1039 1.0140 Dif. 5.8616 4.3390 1.0526
0.259 1.527 Máx. -6.7868 2.0001 0.5555 0.759 0.050 Máx. -5.5794 2.2689 0.5412
Mín. -9.9142 -2.1265 -0.4652 Mín. -11.3939 -1.9872 -0.4418
Dif. 3.1274 4.1266 1.0207 Dif. 5.8145 4.2561 0.9830

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 58 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Desp. Z Giro X Giro Y Coord. X Coord. Y Desp. Z Giro X Giro Y
0.759 0.277 Máx. -6.0304 2.2486 0.5578 1.259 0.277 Máx. -6.1234 2.1818 0.6282
Mín. -10.8792 -1.9862 -0.4209 Mín. -10.9096 -1.9589 -0.2559
Dif. 4.8488 4.2348 0.9788 Dif. 4.7863 4.1406 0.8841
0.759 0.527 Máx. -6.5264 2.2096 0.5692 1.259 0.527 Máx. -6.6136 2.1574 0.6330
Mín. -10.3204 -1.9856 -0.4045 Mín. -10.3666 -1.9665 -0.2559
Dif. 3.7940 4.1952 0.9737 Dif. 3.7531 4.1239 0.8889
0.759 0.777 Máx. -7.0231 2.1575 0.5784 1.259 0.777 Máx. -7.1065 2.1204 0.6363
Mín. -9.7737 -1.9948 -0.3896 Mín. -9.8315 -1.9821 -0.2558
Dif. 2.7507 4.1523 0.9680 Dif. 2.7250 4.1025 0.8921
0.759 1.027 Máx. -7.0676 2.1010 0.5843 1.259 1.027 Máx. -7.3727 2.0768 0.6379
Mín. -9.6974 -2.0181 -0.3794 Mín. -9.5386 -2.0069 -0.2553
Dif. 2.6298 4.1191 0.9636 Dif. 2.1660 4.0837 0.8932
0.759 1.277 Máx. -7.0653 2.0479 0.5862 1.259 1.277 Máx. -7.3709 2.0328 0.6377
Mín. -9.6898 -2.0550 -0.3756 Mín. -9.5323 -2.0400 -0.2545
Dif. 2.6246 4.1029 0.9618 Dif. 2.1615 4.0728 0.8921
0.759 1.527 Máx. -7.0694 2.0110 0.5843 1.259 1.527 Máx. -7.3744 1.9997 0.6379
Mín. -9.6991 -2.1081 -0.3793 Mín. -9.5404 -2.0840 -0.2553
Dif. 2.6298 4.1191 0.9636 Dif. 2.1660 4.0837 0.8932
0.759 1.777 Máx. -7.0266 1.9877 0.5785 1.259 1.777 Máx. -7.1101 1.9749 0.6364
Mín. -9.7773 -2.1646 -0.3896 Mín. -9.8351 -2.1276 -0.2557
Dif. 2.7507 4.1523 0.9680 Dif. 2.7250 4.1025 0.8921
0.759 2.027 Máx. -6.5318 1.9785 0.5693 1.259 2.027 Máx. -6.6190 1.9593 0.6331
Mín. -10.3257 -2.2167 -0.4043 Mín. -10.3720 -2.1646 -0.2558
Dif. 3.7940 4.1952 0.9737 Dif. 3.7531 4.1239 0.8889
0.759 2.277 Máx. -6.0375 1.9790 0.5580 1.259 2.277 Máx. -6.1306 1.9516 0.6283
Mín. -10.8863 -2.2557 -0.4208 Mín. -10.9168 -2.1890 -0.2558
Dif. 4.8488 4.2348 0.9788 Dif. 4.7863 4.1406 0.8841
0.759 2.504 Máx. -5.5882 1.9800 0.5414 1.259 2.504 Máx. -5.6882 1.9484 0.6208
Mín. -11.4027 -2.2761 -0.4416 Mín. -11.4154 -2.1987 -0.2557
Dif. 5.8145 4.2561 0.9830 Dif. 5.7272 4.1472 0.8766
1.009 0.050 Máx. -5.6220 2.2224 0.5742 1.509 0.050 Máx. -5.7509 2.1764 0.6704
Mín. -11.3902 -1.9709 -0.3509 Mín. -11.4447 -1.9391 -0.1683
Dif. 5.7682 4.1932 0.9251 Dif. 5.6938 4.1155 0.8386
1.009 0.277 Máx. -6.0694 2.2092 0.5885 1.509 0.277 Máx. -6.1912 2.1679 0.6697
Mín. -10.8863 -1.9729 -0.3396 Mín. -10.9512 -1.9427 -0.1798
Dif. 4.8169 4.1821 0.9281 Dif. 4.7600 4.1106 0.8495
1.009 0.527 Máx. -6.5628 2.1796 0.5980 1.509 0.527 Máx. -6.6774 2.1453 0.6683
Mín. -10.3367 -1.9779 -0.3310 Mín. -10.4116 -1.9517 -0.1885
Dif. 3.7739 4.1575 0.9290 Dif. 3.7341 4.0970 0.8568
1.009 0.777 Máx. -7.0582 2.1371 0.6053 1.509 0.777 Máx. -7.1668 2.1099 0.6665
Mín. -9.7966 -1.9910 -0.3235 Mín. -9.8793 -1.9691 -0.1956
Dif. 2.7383 4.1281 0.9288 Dif. 2.7125 4.0789 0.8621
1.009 1.027 Máx. -7.2166 2.0888 0.6095 1.509 1.027 Máx. -7.5360 2.0670 0.6646
Mín. -9.6099 -2.0148 -0.3182 Mín. -9.4829 -1.9957 -0.1998
Dif. 2.3933 4.1036 0.9277 Dif. 1.9468 4.0626 0.8644
1.009 1.277 Máx. -7.2147 2.0417 0.6105 1.509 1.277 Máx. -7.5340 2.0227 0.6631
Mín. -9.6032 -2.0489 -0.3158 Mín. -9.4766 -2.0299 -0.2004
Dif. 2.3885 4.0906 0.9264 Dif. 1.9425 4.0526 0.8635
1.009 1.527 Máx. -7.2184 2.0076 0.6096 1.509 1.527 Máx. -7.5378 1.9884 0.6647
Mín. -9.6117 -2.0959 -0.3182 Mín. -9.4847 -2.0742 -0.1998
Dif. 2.3933 4.1035 0.9277 Dif. 1.9468 4.0626 0.8644
1.009 1.777 Máx. -7.0618 1.9838 0.6053 1.509 1.777 Máx. -7.1704 1.9618 0.6665
Mín. -9.8002 -2.1442 -0.3234 Mín. -9.8829 -2.1171 -0.1956
Dif. 2.7383 4.1281 0.9288 Dif. 2.7125 4.0789 0.8621
1.009 2.027 Máx. -6.5682 1.9708 0.5982 1.509 2.027 Máx. -6.6829 1.9444 0.6684
Mín. -10.3421 -2.1868 -0.3309 Mín. -10.4170 -2.1525 -0.1885
Dif. 3.7739 4.1575 0.9290 Dif. 3.7341 4.0970 0.8568
1.009 2.277 Máx. -6.0766 1.9657 0.5887 1.509 2.277 Máx. -6.1985 1.9354 0.6698
Mín. -10.8934 -2.2163 -0.3394 Mín. -10.9585 -2.1752 -0.1797
Dif. 4.8169 4.1821 0.9281 Dif. 4.7600 4.1106 0.8495
MOD-A4-E_Is.00

1.009 2.504 Máx. -5.6308 1.9637 0.5744 1.509 2.504 Máx. -5.7598 1.9318 0.6706
Mín. -11.3990 -2.2295 -0.3507 Mín. -11.4536 -2.1837 -0.1681
Dif. 5.7682 4.1932 0.9251 Dif. 5.6938 4.1155 0.8386
1.259 0.050 Máx. -5.6794 2.1915 0.6206 1.759 0.050 Máx. -5.8343 2.1768 0.7207
Mín. -11.4066 -1.9557 -0.2560 Mín. -11.5036 -1.9205 -0.1035
Dif. 5.7272 4.1472 0.8766 Dif. 5.6693 4.0973 0.8242

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 59 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Desp. Z Giro X Giro Y Coord. X Coord. Y Desp. Z Giro X Giro Y
1.759 0.277 Máx. -6.2704 2.1680 0.7091 2.259 0.277 Máx. -6.4444 2.2082 0.7501
Mín. -11.0100 -1.9241 -0.1247 Mín. -11.1614 -1.8824 -0.1003
Dif. 4.7397 4.0921 0.8338 Dif. 4.7170 4.0906 0.8504
1.759 0.527 Máx. -6.7518 2.1442 0.6995 2.259 0.527 Máx. -6.9144 2.1721 0.7276
Mín. -10.4703 -1.9336 -0.1403 Mín. -10.6119 -1.8906 -0.1223
Dif. 3.7185 4.0778 0.8398 Dif. 3.6975 4.0627 0.8498
1.759 0.777 Máx. -7.2367 2.1064 0.6908 2.259 0.777 Máx. -7.3881 2.1190 0.7076
Mín. -9.9385 -1.9528 -0.1529 Mín. -10.0743 -1.9134 -0.1395
Dif. 2.7018 4.0592 0.8437 Dif. 2.6862 4.0324 0.8471
1.759 1.027 Máx. -7.7056 2.0603 0.6845 2.259 1.027 Máx. -7.8696 2.0570 0.6939
Mín. -9.4397 -1.9821 -0.1604 Mín. -9.5519 -1.9513 -0.1500
Dif. 1.7341 4.0425 0.8449 Dif. 1.6823 4.0082 0.8439
1.759 1.277 Máx. -7.7031 2.0124 0.6815 2.259 1.277 Máx. -8.0472 1.9936 0.6885
Mín. -9.4330 -2.0197 -0.1623 Mín. -9.3614 -2.0007 -0.1529
Dif. 1.7299 4.0321 0.8438 Dif. 1.3142 3.9943 0.8414
1.759 1.527 Máx. -7.7074 1.9749 0.6845 2.259 1.527 Máx. -7.8714 1.9441 0.6938
Mín. -9.4415 -2.0676 -0.1605 Mín. -9.5537 -2.0641 -0.1501
Dif. 1.7341 4.0425 0.8449 Dif. 1.6823 4.0082 0.8439
1.759 1.777 Máx. -7.2403 1.9455 0.6908 2.259 1.777 Máx. -7.3917 1.9061 0.7075
Mín. -9.9421 -2.1137 -0.1529 Mín. -10.0779 -2.1263 -0.1396
Dif. 2.7018 4.0592 0.8437 Dif. 2.6862 4.0324 0.8471
1.759 2.027 Máx. -6.7573 1.9263 0.6995 2.259 2.027 Máx. -6.9198 1.8833 0.7275
Mín. -10.4758 -2.1515 -0.1403 Mín. -10.6173 -2.1794 -0.1224
Dif. 3.7185 4.0778 0.8398 Dif. 3.6975 4.0627 0.8498
1.759 2.277 Máx. -6.2776 1.9167 0.7092 2.259 2.277 Máx. -6.4516 1.8749 0.7500
Mín. -11.0173 -2.1754 -0.1246 Mín. -11.1686 -2.2156 -0.1005
Dif. 4.7397 4.0921 0.8338 Dif. 4.7170 4.0906 0.8504
1.759 2.504 Máx. -5.8433 1.9132 0.7209 2.259 2.504 Máx. -6.0273 1.8732 0.7775
Mín. -11.5126 -2.1842 -0.1033 Mín. -11.6756 -2.2318 -0.0694
Dif. 5.6693 4.0973 0.8242 Dif. 5.6483 4.1050 0.8469
2.009 0.050 Máx. -5.9255 2.1924 0.7598 2.509 0.050 Máx. -6.1062 2.2691 0.7644
Mín. -11.5798 -1.9008 -0.0676 Mín. -11.7559 -1.8763 -0.1273
Dif. 5.6543 4.0932 0.8274 Dif. 5.6497 4.1453 0.8917
2.009 0.277 Máx. -6.3565 2.1822 0.7383 2.509 0.277 Máx. -6.5290 2.2413 0.7404
Mín. -11.0821 -1.9031 -0.0974 Mín. -11.2406 -1.8686 -0.1383
Dif. 4.7256 4.0853 0.8358 Dif. 4.7116 4.1099 0.8787
2.009 0.527 Máx. -6.8324 2.1540 0.7214 2.509 0.527 Máx. -6.9935 2.1936 0.7149
Mín. -10.5389 -1.9127 -0.1186 Mín. -10.6836 -1.8694 -0.1523
Dif. 3.7065 4.0667 0.8400 Dif. 3.6901 4.0631 0.8671
2.009 0.777 Máx. -7.3120 2.1100 0.7065 2.509 0.777 Máx. -7.4611 2.1303 0.6917
Mín. -10.0051 -1.9339 -0.1353 Mín. -10.1414 -1.8929 -0.1648
Dif. 2.6931 4.0439 0.8418 Dif. 2.6803 4.0233 0.8565
2.009 1.027 Máx. -7.7985 2.0572 0.6962 2.509 1.027 Máx. -7.9375 2.0584 0.6764
Mín. -9.4840 -1.9671 -0.1454 Mín. -9.6172 -1.9361 -0.1726
Dif. 1.6855 4.0243 0.8416 Dif. 1.6797 3.9944 0.8490
2.009 1.277 Máx. -7.8751 2.0026 0.6918 2.509 1.277 Máx. -8.2164 1.9857 0.6707
Mín. -9.3964 -2.0098 -0.1481 Mín. -9.3230 -1.9928 -0.1747
Dif. 1.5213 4.0124 0.8398 Dif. 1.1066 3.9785 0.8455
2.009 1.527 Máx. -7.8002 1.9599 0.6961 2.509 1.527 Máx. -7.9393 1.9290 0.6764
Mín. -9.4858 -2.0644 -0.1454 Mín. -9.6190 -2.0655 -0.1726
Dif. 1.6855 4.0243 0.8416 Dif. 1.6797 3.9944 0.8490
2.009 1.777 Máx. -7.3156 1.9266 0.7065 2.509 1.777 Máx. -7.4646 1.8858 0.6916
Mín. -10.0087 -2.1173 -0.1353 Mín. -10.1450 -2.1375 -0.1649
Dif. 2.6931 4.0439 0.8418 Dif. 2.6803 4.0233 0.8565
2.009 2.027 Máx. -6.8378 1.9054 0.7213 2.509 2.027 Máx. -6.9989 1.8622 0.7147
Mín. -10.5443 -2.1613 -0.1187 Mín. -10.6889 -2.2009 -0.1524
Dif. 3.7065 4.0667 0.8400 Dif. 3.6901 4.0631 0.8671
2.009 2.277 Máx. -6.3638 1.8957 0.7383 2.509 2.277 Máx. -6.5362 1.8612 0.7402
Mín. -11.0894 -2.1896 -0.0975 Mín. -11.2478 -2.2487 -0.1384
Dif. 4.7256 4.0853 0.8358 Dif. 4.7116 4.1099 0.8787
MOD-A4-E_Is.00

2.009 2.504 Máx. -5.9345 1.8934 0.7598 2.509 2.504 Máx. -6.1151 1.8688 0.7643
Mín. -11.5887 -2.1998 -0.0676 Mín. -11.7648 -2.2765 -0.1275
Dif. 5.6543 4.0932 0.8274 Dif. 5.6497 4.1453 0.8917
2.259 0.050 Máx. -6.0183 2.2243 0.7776 2.759 0.050 Máx. -6.1810 2.2933 0.7042
Mín. -11.6666 -1.8807 -0.0693 Mín. -11.8374 -1.9288 -0.2842
Dif. 5.6483 4.1050 0.8469 Dif. 5.6564 4.2221 0.9884

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 60 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Desp. Z Giro X Giro Y Coord. X Coord. Y Desp. Z Giro X Giro Y
2.759 0.277 Máx. -6.6046 2.2676 0.7037 3.259 0.277 Máx. -6.6910 2.2672 0.5591
Mín. -11.3109 -1.8674 -0.2124 Mín. -11.3973 -1.8679 -0.3571
Dif. 4.7063 4.1350 0.9162 Dif. 4.7063 4.1350 0.9162
2.759 0.527 Máx. -7.0640 2.2122 0.6788 3.259 0.527 Máx. -7.1505 2.2122 0.5531
Mín. -10.7475 -1.8525 -0.2064 Mín. -10.8340 -1.8525 -0.3321
Dif. 3.6834 4.0647 0.8851 Dif. 3.6834 4.0647 0.8852
2.759 0.777 Máx. -7.5258 2.1398 0.6569 3.259 0.777 Máx. -7.6122 2.1401 0.5543
Mín. -10.2015 -1.8756 -0.2079 Mín. -10.2879 -1.8754 -0.3105
Dif. 2.6757 4.0155 0.8648 Dif. 2.6757 4.0155 0.8648
2.759 1.027 Máx. -7.9979 2.0599 0.6434 3.259 1.027 Máx. -8.0843 2.0602 0.5555
Mín. -9.6758 -1.9240 -0.2095 Mín. -9.7621 -1.9238 -0.2973
Dif. 1.6778 3.9840 0.8529 Dif. 1.6778 3.9840 0.8529
2.759 1.277 Máx. -8.3795 1.9799 0.6386 3.259 1.277 Máx. -8.4658 1.9799 0.5556
Mín. -9.2769 -1.9869 -0.2097 Mín. -9.3633 -1.9869 -0.2928
Dif. 0.8974 3.9668 0.8484 Dif. 0.8974 3.9668 0.8484
2.759 1.527 Máx. -7.9997 1.9169 0.6433 3.259 1.527 Máx. -8.0860 1.9168 0.5554
Mín. -9.6775 -2.0670 -0.2095 Mín. -9.7638 -2.0671 -0.2974
Dif. 1.6778 3.9840 0.8529 Dif. 1.6778 3.9840 0.8529
2.759 1.777 Máx. -7.5293 1.8685 0.6568 3.259 1.777 Máx. -7.6157 1.8683 0.5541
Mín. -10.2050 -2.1470 -0.2080 Mín. -10.2914 -2.1471 -0.3107
Dif. 2.6757 4.0155 0.8648 Dif. 2.6757 4.0155 0.8648
2.759 2.027 Máx. -7.0694 1.8453 0.6786 3.259 2.027 Máx. -7.1558 1.8453 0.5528
Mín. -10.7528 -2.2194 -0.2065 Mín. -10.8392 -2.2194 -0.3323
Dif. 3.6834 4.0647 0.8851 Dif. 3.6834 4.0647 0.8852
2.759 2.277 Máx. -6.6118 1.8600 0.7036 3.259 2.277 Máx. -6.6981 1.8605 0.5588
Mín. -11.3181 -2.2750 -0.2126 Mín. -11.4043 -2.2745 -0.3574
Dif. 4.7063 4.1350 0.9162 Dif. 4.7063 4.1350 0.9162
2.759 2.504 Máx. -6.1899 1.9214 0.7041 3.259 2.504 Máx. -6.2758 1.9223 0.6289
Mín. -11.8462 -2.3007 -0.2844 Mín. -11.9322 -2.2998 -0.3595
Dif. 5.6564 4.2221 0.9884 Dif. 5.6564 4.2221 0.9884
3.009 0.200 Máx. -6.5474 2.2605 0.6851 3.509 0.050 Máx. -6.2795 2.2689 0.4781
Mín. -11.5486 -2.0404 -0.3421 Mín. -11.9292 -1.8764 -0.4137
Dif. 5.0012 4.3008 1.0272 Dif. 5.6497 4.1453 0.8918
3.009 0.277 Máx. -6.6661 2.2692 0.6410 3.509 0.277 Máx. -6.7024 2.2416 0.4877
Mín. -11.3649 -1.8749 -0.2957 Mín. -11.4140 -1.8683 -0.3910
Dif. 4.6988 4.1442 0.9367 Dif. 4.7116 4.1099 0.8787
3.009 0.527 Máx. -7.1191 2.2187 0.6179 3.509 0.527 Máx. -7.1668 2.1943 0.5007
Mín. -10.7985 -1.8413 -0.2720 Mín. -10.8569 -1.8687 -0.3664
Dif. 3.6794 4.0601 0.8899 Dif. 3.6901 4.0631 0.8671
3.009 0.777 Máx. -7.5772 2.1438 0.6056 3.509 0.777 Máx. -7.6342 2.1311 0.5125
Mín. -10.2507 -1.8672 -0.2597 Mín. -10.3145 -1.8922 -0.3441
Dif. 2.6735 4.0110 0.8653 Dif. 2.6803 4.0233 0.8565
3.009 1.027 Máx. -8.0474 2.0604 0.5988 3.509 1.027 Máx. -8.1105 2.0589 0.5197
Mín. -9.7243 -1.9187 -0.2532 Mín. -9.7902 -1.9355 -0.3293
Dif. 1.6769 3.9791 0.8520 Dif. 1.6797 3.9944 0.8490
3.009 1.277 Máx. -8.5336 1.9772 0.5964 3.509 1.277 Máx. -8.3893 1.9858 0.5216
Mín. -9.2201 -1.9842 -0.2509 Mín. -9.4959 -1.9927 -0.3238
Dif. 0.6865 3.9615 0.8473 Dif. 1.1066 3.9785 0.8455
3.009 1.527 Máx. -8.0491 1.9116 0.5988 3.509 1.527 Máx. -8.1122 1.9287 0.5196
Mín. -9.7261 -2.0674 -0.2532 Mín. -9.7919 -2.0658 -0.3294
Dif. 1.6769 3.9791 0.8520 Dif. 1.6797 3.9944 0.8490
3.009 1.777 Máx. -7.5807 1.8601 0.6054 3.509 1.777 Máx. -7.6376 1.8852 0.5123
Mín. -10.2542 -2.1509 -0.2598 Mín. -10.3179 -2.1381 -0.3443
Dif. 2.6735 4.0110 0.8653 Dif. 2.6803 4.0233 0.8565
3.009 2.027 Máx. -7.1244 1.8341 0.6178 3.509 2.027 Máx. -7.1720 1.8616 0.5004
Mín. -10.8038 -2.2260 -0.2721 Mín. -10.8621 -2.2015 -0.3667
Dif. 3.6794 4.0601 0.8899 Dif. 3.6901 4.0631 0.8671
3.009 2.277 Máx. -6.6732 1.8675 0.6408 3.509 2.277 Máx. -6.7094 1.8609 0.4873
Mín. -11.3720 -2.2766 -0.2959 Mín. -11.4210 -2.2489 -0.3913
Dif. 4.6988 4.1442 0.9367 Dif. 4.7116 4.1099 0.8787
MOD-A4-E_Is.00

3.009 2.354 Máx. -6.5551 2.0329 0.6850 3.509 2.504 Máx. -6.2882 1.8690 0.4777
Mín. -11.5563 -2.2679 -0.3422 Mín. -11.9379 -2.2763 -0.4140
Dif. 5.0012 4.3008 1.0272 Dif. 5.6497 4.1453 0.8918
3.259 0.050 Máx. -6.2670 2.2923 0.6291 3.759 0.050 Máx. -6.2799 2.2261 0.4228
Mín. -11.9234 -1.9297 -0.3593 Mín. -11.9281 -1.8789 -0.4241
Dif. 5.6563 4.2221 0.9884 Dif. 5.6482 4.1050 0.8469

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 61 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Desp. Z Giro X Giro Y Coord. X Coord. Y Desp. Z Giro X Giro Y
3.759 0.277 Máx. -6.7055 2.2100 0.4519 4.259 0.277 Máx. -6.7082 2.1713 0.4751
Mín. -11.4225 -1.8806 -0.3985 Mín. -11.4479 -1.9209 -0.3587
Dif. 4.7169 4.0906 0.8504 Dif. 4.7397 4.0921 0.8338
3.759 0.527 Máx. -7.1751 2.1739 0.4726 4.259 0.527 Máx. -7.1886 2.1476 0.4910
Mín. -10.8725 -1.8888 -0.3773 Mín. -10.9070 -1.9302 -0.3489
Dif. 3.6975 4.0627 0.8498 Dif. 3.7185 4.0778 0.8399
3.759 0.777 Máx. -7.6483 2.1206 0.4888 4.259 0.777 Máx. -7.6726 2.1091 0.5035
Mín. -10.3345 -1.9118 -0.3583 Mín. -10.3743 -1.9502 -0.3401
Dif. 2.6862 4.0324 0.8471 Dif. 2.7018 4.0592 0.8437
3.759 1.027 Máx. -8.1295 2.0579 0.4987 4.259 1.027 Máx. -8.1408 2.0619 0.5111
Mín. -9.8117 -1.9503 -0.3452 Mín. -9.8749 -1.9806 -0.3338
Dif. 1.6822 4.0082 0.8439 Dif. 1.7341 4.0425 0.8449
3.759 1.277 Máx. -8.3069 1.9938 0.5014 4.259 1.277 Máx. -8.1380 2.0128 0.5129
Mín. -9.6210 -2.0005 -0.3400 Mín. -9.8680 -2.0193 -0.3309
Dif. 1.3142 3.9943 0.8414 Dif. 1.7299 4.0321 0.8438
3.759 1.527 Máx. -8.1312 1.9436 0.4986 4.259 1.527 Máx. -8.1425 1.9740 0.5110
Mín. -9.8134 -2.0647 -0.3453 Mín. -9.8765 -2.0684 -0.3339
Dif. 1.6823 4.0082 0.8439 Dif. 1.7341 4.0425 0.8449
3.759 1.777 Máx. -7.6517 1.9050 0.4886 4.259 1.777 Máx. -7.6758 1.9435 0.5033
Mín. -10.3378 -2.1274 -0.3585 Mín. -10.3776 -2.1157 -0.3404
Dif. 2.6862 4.0324 0.8471 Dif. 2.7018 4.0592 0.8437
3.759 2.027 Máx. -7.1802 1.8817 0.4722 4.259 2.027 Máx. -7.1935 1.9234 0.4906
Mín. -10.8776 -2.1809 -0.3776 Mín. -10.9119 -2.1544 -0.3492
Dif. 3.6975 4.0627 0.8498 Dif. 3.7185 4.0778 0.8399
3.759 2.277 Máx. -6.7124 1.8733 0.4515 4.259 2.277 Máx. -6.7148 1.9138 0.4746
Mín. -11.4294 -2.2173 -0.3989 Mín. -11.4545 -2.1783 -0.3592
Dif. 4.7170 4.0906 0.8504 Dif. 4.7397 4.0921 0.8338
3.759 2.504 Máx. -6.2885 1.8716 0.4223 4.259 2.504 Máx. -6.2814 1.9119 0.4520
Mín. -11.9367 -2.2335 -0.4246 Mín. -11.9507 -2.1855 -0.3722
Dif. 5.6482 4.1050 0.8469 Dif. 5.6693 4.0973 0.8242
4.009 0.050 Máx. -6.2757 2.1955 0.4210 4.509 0.050 Máx. -6.2764 2.1756 0.5085
Mín. -11.9299 -1.8976 -0.4064 Mín. -11.9702 -1.9399 -0.3301
Dif. 5.6542 4.0932 0.8274 Dif. 5.6938 4.1155 0.8386
4.009 0.277 Máx. -6.7059 2.1853 0.4501 4.509 0.277 Máx. -6.7163 2.1697 0.5227
Mín. -11.4314 -1.9000 -0.3857 Mín. -11.4763 -1.9409 -0.3268
Dif. 4.7256 4.0853 0.8358 Dif. 4.7600 4.1106 0.8495
4.009 0.527 Máx. -7.1808 2.1569 0.4704 4.509 0.527 Máx. -7.2017 2.1479 0.5329
Mín. -10.8873 -1.9098 -0.3697 Mín. -10.9358 -1.9491 -0.3239
Dif. 3.7065 4.0667 0.8401 Dif. 3.7341 4.0970 0.8568
4.009 0.777 Máx. -7.6597 2.1123 0.4863 4.509 0.777 Máx. -7.6904 2.1121 0.5409
Mín. -10.3528 -1.9316 -0.3555 Mín. -10.4028 -1.9668 -0.3211
Dif. 2.6931 4.0439 0.8418 Dif. 2.7125 4.0789 0.8621
4.009 1.027 Máx. -8.1457 2.0586 0.4960 4.509 1.027 Máx. -8.0590 2.0684 0.5456
Mín. -9.8312 -1.9657 -0.3456 Mín. -10.0058 -1.9942 -0.3188
Dif. 1.6855 4.0243 0.8416 Dif. 1.9468 4.0626 0.8644
4.009 1.277 Máx. -8.2221 2.0029 0.4984 4.509 1.277 Máx. -8.0568 2.0231 0.5464
Mín. -9.7434 -2.0095 -0.3414 Mín. -9.9993 -2.0295 -0.3171
Dif. 1.5213 4.0124 0.8398 Dif. 1.9425 4.0526 0.8635
4.009 1.527 Máx. -8.1473 1.9591 0.4958 4.509 1.527 Máx. -8.0606 1.9878 0.5455
Mín. -9.8328 -2.0652 -0.3457 Mín. -10.0074 -2.0748 -0.3189
Dif. 1.6855 4.0243 0.8416 Dif. 1.9468 4.0626 0.8644
4.009 1.777 Máx. -7.6630 1.9248 0.4861 4.509 1.777 Máx. -7.6936 1.9603 0.5407
Mín. -10.3561 -2.1191 -0.3558 Mín. -10.4060 -2.1186 -0.3213
Dif. 2.6931 4.0439 0.8418 Dif. 2.7125 4.0789 0.8621
4.009 2.027 Máx. -7.1859 1.9028 0.4700 4.509 2.027 Máx. -7.2066 1.9424 0.5326
Mín. -10.8923 -2.1638 -0.3700 Mín. -10.9407 -2.1546 -0.3242
Dif. 3.7065 4.0667 0.8401 Dif. 3.7341 4.0970 0.8568
4.009 2.277 Máx. -6.7126 1.8928 0.4496 4.509 2.277 Máx. -6.7229 1.9340 0.5223
Mín. -11.4382 -2.1925 -0.3862 Mín. -11.4829 -2.1766 -0.3272
Dif. 4.7256 4.0853 0.8358 Dif. 4.7600 4.1106 0.8495
MOD-A4-E_Is.00

4.009 2.504 Máx. -6.2842 1.8904 0.4204 4.509 2.504 Máx. -6.2846 1.9329 0.5079
Mín. -11.9384 -2.2028 -0.4070 Mín. -11.9784 -2.1826 -0.3307
Dif. 5.6542 4.0932 0.8274 Dif. 5.6938 4.1155 0.8386
4.259 0.050 Máx. -6.2731 2.1783 0.4526 4.759 0.050 Máx. -6.2888 2.1880 0.5848
Mín. -11.9424 -1.9190 -0.3716 Mín. -12.0160 -1.9592 -0.2918
Dif. 5.6693 4.0973 0.8242 Dif. 5.7272 4.1472 0.8766

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 62 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Desp. Z Giro X Giro Y Coord. X Coord. Y Desp. Z Giro X Giro Y
4.759 0.277 Máx. -6.7331 2.1813 0.5874 5.259 0.277 Máx. -6.7997 2.2451 0.7336
Mín. -11.5193 -1.9593 -0.2967 Mín. -11.6485 -1.9896 -0.2452
Dif. 4.7862 4.1406 0.8841 Dif. 4.8488 4.2348 0.9787
4.759 0.527 Máx. -7.2230 2.1584 0.5895 5.259 0.527 Máx. -7.2965 2.2075 0.7178
Mín. -10.9761 -1.9655 -0.2994 Mín. -11.0904 -1.9877 -0.2558
Dif. 3.7530 4.1239 0.8889 Dif. 3.7940 4.1952 0.9737
4.759 0.777 Máx. -7.7156 2.1217 0.5908 5.259 0.777 Máx. -7.7935 2.1566 0.7037
Mín. -10.4406 -1.9808 -0.3012 Mín. -10.5441 -1.9957 -0.2643
Dif. 2.7250 4.1025 0.8921 Dif. 2.7506 4.1523 0.9680
4.759 1.027 Máx. -7.9814 2.0778 0.5912 5.259 1.027 Máx. -7.8382 2.1009 0.6939
Mín. -10.1474 -2.0059 -0.3020 Mín. -10.4679 -2.0182 -0.2698
Dif. 2.1660 4.0837 0.8932 Dif. 2.6297 4.1191 0.9636
4.759 1.277 Máx. -7.9794 2.0333 0.5906 5.259 1.277 Máx. -7.8358 2.0483 0.6902
Mín. -10.1409 -2.0396 -0.3015 Mín. -10.4603 -2.0546 -0.2715
Dif. 2.1614 4.0728 0.8921 Dif. 2.6246 4.1029 0.9618
4.759 1.527 Máx. -7.9830 1.9996 0.5912 5.259 1.527 Máx. -7.8397 2.0119 0.6938
Mín. -10.1489 -2.0841 -0.3020 Mín. -10.4695 -2.1072 -0.2698
Dif. 2.1660 4.0837 0.8932 Dif. 2.6297 4.1191 0.9636
4.759 1.777 Máx. -7.7187 1.9744 0.5907 5.259 1.777 Máx. -7.7967 1.9893 0.7037
Mín. -10.4437 -2.1281 -0.3014 Mín. -10.5473 -2.1630 -0.2643
Dif. 2.7250 4.1025 0.8921 Dif. 2.7506 4.1523 0.9680
4.759 2.027 Máx. -7.2278 1.9590 0.5893 5.259 2.027 Máx. -7.3012 1.9812 0.7178
Mín. -10.9808 -2.1649 -0.2996 Mín. -11.0952 -2.2140 -0.2559
Dif. 3.7530 4.1239 0.8889 Dif. 3.7940 4.1952 0.9737
4.759 2.277 Máx. -6.7395 1.9525 0.5871 5.259 2.277 Máx. -6.8060 1.9831 0.7335
Mín. -11.5258 -2.1881 -0.2970 Mín. -11.6548 -2.2517 -0.2452
Dif. 4.7862 4.1406 0.8841 Dif. 4.8488 4.2348 0.9787
4.759 2.504 Máx. -6.2968 1.9523 0.5843 5.259 2.504 Máx. -6.3555 1.9851 0.7538
Mín. -12.0240 -2.1948 -0.2923 Mín. -12.1699 -2.2710 -0.2292
Dif. 5.7272 4.1472 0.8765 Dif. 5.8144 4.2561 0.9829
5.009 0.050 Máx. -6.3119 2.2183 0.6693 5.509 0.050 Máx. -6.3963 2.3236 0.8262
Mín. -12.0801 -1.9749 -0.2558 Mín. -12.2578 -2.0154 -0.2264
Dif. 5.7682 4.1932 0.9251 Dif. 5.8615 4.3390 1.0526
5.009 0.277 Máx. -6.7602 2.2067 0.6596 5.509 0.277 Máx. -6.8531 2.2919 0.8009
Mín. -11.5771 -1.9753 -0.2684 Mín. -11.7302 -2.0048 -0.2330
Dif. 4.8168 4.1821 0.9280 Dif. 4.8771 4.2967 1.0338
5.009 0.527 Máx. -7.2541 2.1787 0.6527 5.509 0.527 Máx. -7.3519 2.2406 0.7779
Mín. -11.0279 -1.9788 -0.2763 Mín. -11.1615 -1.9913 -0.2416
Dif. 3.7739 4.1575 0.9290 Dif. 3.8096 4.2319 1.0194
5.009 0.777 Máx. -7.7496 2.1371 0.6466 5.509 0.777 Máx. -7.7864 2.1774 0.7559
Mín. -10.4879 -1.9910 -0.2822 Mín. -10.6703 -1.9931 -0.2506
Dif. 2.7383 4.1281 0.9288 Dif. 2.8839 4.1706 1.0064
5.009 1.027 Máx. -7.9079 2.0891 0.6421 5.509 1.027 Máx. -7.7725 2.1114 0.7401
Mín. -10.3011 -2.0144 -0.2856 Mín. -10.6476 -2.0159 -0.2567
Dif. 2.3933 4.1035 0.9277 Dif. 2.8750 4.1273 0.9968
5.009 1.277 Máx. -7.9058 2.0421 0.6400 5.509 1.277 Máx. -7.7695 2.0506 0.7343
Mín. -10.2943 -2.0484 -0.2863 Mín. -10.6388 -2.0569 -0.2586
Dif. 2.3885 4.0906 0.9264 Dif. 2.8693 4.1075 0.9929
5.009 1.527 Máx. -7.9094 2.0081 0.6421 5.509 1.527 Máx. -7.7741 2.0096 0.7401
Mín. -10.3027 -2.0954 -0.2856 Mín. -10.6491 -2.1177 -0.2566
Dif. 2.3933 4.1035 0.9277 Dif. 2.8750 4.1273 0.9968
5.009 1.777 Máx. -7.7527 1.9846 0.6465 5.509 1.777 Máx. -7.7895 1.9868 0.7559
Mín. -10.4910 -2.1434 -0.2822 Mín. -10.6735 -2.1838 -0.2506
Dif. 2.7383 4.1281 0.9288 Dif. 2.8839 4.1706 1.0064
5.009 2.027 Máx. -7.2588 1.9723 0.6526 5.509 2.027 Máx. -7.3566 1.9848 0.7779
Mín. -11.0327 -2.1852 -0.2764 Mín. -11.1663 -2.2471 -0.2416
Dif. 3.7739 4.1575 0.9290 Dif. 3.8096 4.2319 1.0194
5.009 2.277 Máx. -6.7666 1.9687 0.6594 5.509 2.277 Máx. -6.8594 1.9983 0.8009
Mín. -11.5834 -2.2134 -0.2686 Mín. -11.7366 -2.2984 -0.2329
Dif. 4.8168 4.1821 0.9280 Dif. 4.8771 4.2967 1.0338
MOD-A4-E_Is.00

5.009 2.504 Máx. -6.3198 1.9681 0.6690 5.509 2.504 Máx. -6.4042 2.0088 0.8262
Mín. -12.0880 -2.2251 -0.2561 Mín. -12.2657 -2.3301 -0.2264
Dif. 5.7682 4.1932 0.9251 Dif. 5.8615 4.3390 1.0526
5.259 0.050 Máx. -6.3476 2.2644 0.7539 5.759 0.050 Máx. -6.4583 2.3815 0.8729
Mín. -12.1621 -1.9917 -0.2291 Mín. -12.3580 -2.0713 -0.2817
Dif. 5.8144 4.2561 0.9829 Dif. 5.8997 4.4528 1.1545

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 63 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Desp. Z Giro X Giro Y


5.759 0.277 Máx. -6.9208 2.3357 0.8574
Mín. -11.8159 -2.0259 -0.2407
Dif. 4.8951 4.3616 1.0981
5.759 0.527 Máx. -7.4198 2.2711 0.8264
Mín. -11.2373 -1.9883 -0.2380
Dif. 3.8176 4.2594 1.0644
5.759 0.777 Máx. -7.7257 2.1962 0.7944
Mín. -10.8650 -1.9823 -0.2434
Dif. 3.1393 4.1785 1.0378
5.759 1.027 Máx. -7.7099 2.1194 0.7721
Mín. -10.8373 -2.0072 -0.2486
Dif. 3.1274 4.1266 1.0207
5.759 1.277 Máx. -7.7061 2.0488 0.7639
Mín. -10.8269 -2.0551 -0.2501
Dif. 3.1208 4.1039 1.0140
5.759 1.527 Máx. -7.7115 2.0009 0.7722
Mín. -10.8388 -2.1257 -0.2486
Dif. 3.1274 4.1266 1.0207
5.759 1.777 Máx. -7.7288 1.9759 0.7944
Mín. -10.8681 -2.2025 -0.2434
Dif. 3.1393 4.1785 1.0378
5.759 2.027 Máx. -7.4245 1.9818 0.8265
Mín. -11.2421 -2.2775 -0.2380
Dif. 3.8176 4.2594 1.0644
5.759 2.277 Máx. -6.9271 2.0193 0.8574
Mín. -11.8223 -2.3423 -0.2407
Dif. 4.8951 4.3616 1.0981
5.759 2.504 Máx. -6.4662 2.0646 0.8730
Mín. -12.3659 -2.3881 -0.2815
Dif. 5.8997 4.4528 1.1545
5.968 0.277 Máx. -6.9909 2.3676 0.8921
Mín. -11.8871 -2.0819 -0.2524
Dif. 4.8962 4.4495 1.1446
5.968 0.527 Máx. -7.4853 2.2993 0.8532
Mín. -11.3021 -1.9763 -0.2350
Dif. 3.8169 4.2757 1.0882
5.968 0.777 Máx. -7.6765 2.2149 0.8121
Mín. -11.0336 -1.9599 -0.2396
Dif. 3.3571 4.1748 1.0516
5.968 1.027 Máx. -7.6590 2.1262 0.7850
Mín. -11.0006 -1.9909 -0.2451
Dif. 3.3416 4.1170 1.0300
5.968 1.277 Máx. -7.6544 2.0431 0.7751
Mín. -10.9885 -2.0494 -0.2466
Dif. 3.3341 4.0924 1.0218
5.968 1.527 Máx. -7.6606 1.9845 0.7850
Mín. -11.0021 -2.1325 -0.2451
Dif. 3.3416 4.1170 1.0300
5.968 1.777 Máx. -7.6797 1.9535 0.8121
Mín. -11.0368 -2.2213 -0.2396
Dif. 3.3571 4.1748 1.0516
5.968 2.027 Máx. -7.4900 1.9698 0.8533
Mín. -11.3069 -2.3058 -0.2349
Dif. 3.8169 4.2757 1.0882
5.968 2.277 Máx. -6.9973 2.0753 0.8922
Mín. -11.8935 -2.3742 -0.2523
Dif. 4.8962 4.4495 1.1446
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 64 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.11.2.2 ESQUEMA DE DESPLAZAMIENTOS

E.L.S. Hormigón. Desplazamiento en Z

Deformada
MOD-A4-E_Is.00

El desplazamiento o deformada máxima obtenida según las gráficas es de 12,78 mm.

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 65 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.11.3 COMPROBACIÓN E.L.U. VIGAS DE CIMENTACIÓN

COMPROBACIONES DE RESISTENCIA (NCH430.OF2008-DECRETO 60/2011)


Vigas Estado
Disp. Arm. Q Q S. N,M N,M S. Tc Tst Tsl TNMx TVx TVy TVXst TVYst T,Disp.sl T,Disp.st T,Geom.sl T,Arm.st
'2.361 m' '0.000 m' '2.361 m' '2.361 m' '2.609 m' '2.609 m' '0.000 m' '2.559 m' '2.609 m' '2.609 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m'
V-001: F1 - F3 Cumple Cumple N.P.(1) N.P.(1) CUMPLE
 = 16.7  = 31.2  = 37.6  = 59.4  = 56.1  = 36.3  = 38.2  = 90.2  = 56.3 Cumple Cumple Cumple Cumple Cumple
'0.000 m' '2.361 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m'
V-002: F3 - F5 Cumple Cumple N.P.(1) N.P.(1) CUMPLE
 = 15.9  = 29.9  = 35.7  = 57.8  = 55.7  = 36.0  = 38.2  = 88.7  = 55.9 Cumple Cumple Cumple Cumple Cumple
'2.361 m' '0.000 m' '2.361 m' '2.361 m' '2.609 m' '2.609 m' '0.000 m' '2.559 m' '2.609 m' '2.609 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m'
V-003: F2 - F4 Cumple Cumple N.P.(1) N.P.(1) CUMPLE
 = 16.7  = 31.2  = 37.6  = 59.4  = 56.1  = 36.3  = 38.2  = 90.2  = 56.3 Cumple Cumple Cumple Cumple Cumple
'0.000 m' '2.361 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m'
V-004: F4 - F6 Cumple Cumple N.P.(1) N.P.(1) CUMPLE
 = 16.0  = 29.9  = 35.6  = 57.7  = 55.7  = 36.0  = 38.2  = 88.7  = 55.9 Cumple Cumple Cumple Cumple Cumple
'1.906 m' '0.000 m' '1.906 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m'
V-005: F2 - F1 Cumple Cumple N.P.(1) N.P.(1) CUMPLE
 = 15.9  = 32.4  = 26.7  = 53.2  = 22.6  = 16.8  = 38.2  = 84.6  = 43.0 Cumple Cumple Cumple Cumple Cumple
'1.906 m' '0.000 m' '1.906 m' '0.000 m' '0.000 m' '0.077 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m' '0.000 m'
V-006: F6 - F5 Cumple Cumple N.P.(1) N.P.(1) CUMPLE
 = 16.3  = 33.0  = 26.6  = 53.2  = 21.1  = 15.7  = 38.2  = 84.5  = 42.6 Cumple Cumple Cumple Cumple Cumple
Notación:
Disp.: Disposiciones relativas a las armaduras
Arm.: Armadura mínima y máxima
Q: Estado límite de agotamiento frente a cortante (combinaciones no sísmicas)
Q S.: Estado límite de agotamiento frente a cortante (combinaciones sísmicas)
N,M: Estado límite de agotamiento frente a solicitaciones normales (combinaciones no sísmicas)
N,M S.: Estado límite de agotamiento frente a solicitaciones normales (combinaciones sísmicas)
Tc: Estado límite de agotamiento por torsión. Compresión oblicua.
Tst: Estado límite de agotamiento por torsión. Tracción en el alma.
Tsl: Estado límite de agotamiento por torsión. Tracción en las armaduras longitudinales.
TNMx: Estado límite de agotamiento por torsión. Interacción entre torsión y esfuerzos normales. Flexión alrededor del eje X.
TVx: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje X. Compresión oblicua
TVy: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje Y. Compresión oblicua
TVXst: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje X. Tracción en el alma.
TVYst: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje Y. Tracción en el alma.
T,Disp.sl: Estado límite de agotamiento por torsión. Separación entre las barras de la armadura longitudinal.
T,Disp.st: Estado límite de agotamiento por torsión. Separación entre las barras de la armadura transversal.
T,Geom.sl: Estado límite de agotamiento por torsión. Diámetro mínimo de la armadura longitudinal.
T,Arm.st: Estado límite de agotamiento por torsión. Cuantía mínima de estribos cerrados.
x: Distancia al origen de la barra
: Coeficiente de aprovechamiento (%)
N.P.: No procede
Comprobaciones que no proceden (N.P.):
(1) No hay interacción entre torsión y cortante para ninguna combinación. Por lo tanto, la comprobación no procede.

COMPROBACIONES DE FISURACIÓN (NCH430.OF2008-DECRETO 60/2011)


Vigas Estado
sC,sup. sC,Lat.Der. sC,inf. sC,Lat.Izq.
x: 1.059 m x: 2.609 m
V-001: F1 - F3 N.P.(1) N.P.(1) CUMPLE
Cumple Cumple
x: 1.675 m x: 0 m
V-002: F3 - F5 N.P.(1) N.P.(1) CUMPLE
Cumple Cumple
x: 1.059 m x: 2.609 m
V-003: F2 - F4 N.P.(1) N.P.(1) CUMPLE
Cumple Cumple
x: 1.675 m x: 0 m
V-004: F4 - F6 N.P.(1) N.P.(1) CUMPLE
Cumple Cumple
x: 1.077 m x: 0 m
V-005: F2 - F1 N.P.(1) N.P.(1) CUMPLE
Cumple Cumple
x: 1.077 m x: 0 m
V-006: F6 - F5 N.P.(1) N.P.(1) CUMPLE
Cumple Cumple
Notación:
sC,sup.: Comprobación de la separación máxima entre barras: Cara superior
sC,Lat.Der.: Comprobación de la separación máxima entre barras: Cara lateral derecha
sC,inf.: Comprobación de la separación máxima entre barras: Cara inferior
sC,Lat.Izq.: Comprobación de la separación máxima entre barras: Cara lateral izquierda
x: Distancia al origen de la barra
: Coeficiente de aprovechamiento (%)
N.P.: No procede
Comprobaciones que no proceden (N.P.):
(1) La comprobación no procede, ya que no hay ninguna armadura traccionada.
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 66 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.12 TENSIONES SOBRE EL TERRENO


12.12.1 ESQUEMA DE TENSIONES SOBRE EL TERRENO

La tensión máxima ejercida por la losa en el terreno es de 0,042 MPa.

12.12.2 TENSIONES DEL TERRENO BAJO VIGAS DE CIMENTACIÓN

Tensión admisible en situaciones persistentes: 0.075 MPa


Tensión admisible en situaciones accidentales: 0.100 MPa

Situaciones persistentes o transitorias


Viga Tensión media Tensión en bordes
Estado
Pórtico Tramo Dimensión (MPa) (MPa)
1 V-001: F1-F3 25x30 0.035 0.035 Cumple
1 V-002: F3-F5 25x30 0.036 0.036 Cumple
2 V-003: F2-F4 25x30 0.036 0.036 Cumple
2 V-004: F4-F6 25x30 0.037 0.038 Cumple
3 V-005: F2-F1 25x30 0.033 0.033 Cumple
4 V-006: F6-F5 25x30 0.037 0.037 Cumple

Situaciones accidentales
Viga Tensión media Tensión en bordes
Estado
(MPa) (MPa)
MOD-A4-E_Is.00

Pórtico Tramo Dimensión


1 V-001: F1-F3 25x30 0.043 0.044 Cumple
1 V-002: F3-F5 25x30 0.045 0.046 Cumple
2 V-003: F2-F4 25x30 0.043 0.044 Cumple

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 67 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Situaciones accidentales
Viga Tensión media Tensión en bordes
Estado
Pórtico Tramo Dimensión (MPa) (MPa)
2 V-004: F4-F6 25x30 0.045 0.046 Cumple
3 V-005: F2-F1 25x30 0.039 0.039 Cumple
4 V-006: F6-F5 25x30 0.043 0.043 Cumple

12.13 ESFUERZO Y ARMADO DE PILARES


12.13.1 ARMADO DE PILARES

Armado de pilares
Hormigón: H25
Geometría Armaduras
Barras Estribos Aprov.
Pilar Dimensiones Tramo Estado
Planta
(cm) (m) Cuantía Separación (%)
Esquina Cara X Cara Y Descripción(1)
(%) (cm)
F1 Baja 40x40 0.00/1.05 4Ø16 2Ø16 2Ø16 1.01 1eØ10 8 44.3 Cumple
Cimentación - - 4Ø16 2Ø16 2Ø16 1.01 1eØ10 - 21.6 Cumple
F2 Baja 40x40 0.00/1.05 4Ø16 2Ø16 2Ø16 1.01 1eØ10 8 44.4 Cumple
Cimentación - - 4Ø16 2Ø16 2Ø16 1.01 1eØ10 - 21.6 Cumple
F3 Baja 40x40 0.00/1.05 4Ø16 2Ø16 2Ø16 1.01 1eØ10 5 30.4 Cumple
Cimentación - - 4Ø16 2Ø16 2Ø16 1.01 1eØ10 - 22.9 Cumple
F4 Baja 40x40 0.00/1.05 4Ø16 2Ø16 2Ø16 1.01 1eØ10 5 30.4 Cumple
Cimentación - - 4Ø16 2Ø16 2Ø16 1.01 1eØ10 - 22.9 Cumple
F5 Baja 40x40 0.00/1.05 4Ø16 2Ø16 2Ø16 1.01 1eØ10 8 44.7 Cumple
Cimentación - - 4Ø16 2Ø16 2Ø16 1.01 1eØ10 - 22.1 Cumple
F6 Baja 40x40 0.00/1.05 4Ø16 2Ø16 2Ø16 1.01 1eØ10 8 44.7 Cumple
Cimentación - - 4Ø16 2Ø16 2Ø16 1.01 1eØ10 - 22.1 Cumple
MOD-A4-E_Is.00

Notas:
(1)
e = estribo, r = rama

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 68 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.13.2 ESFUERZOS DE PILARES

- Tramo: Nivel inicial / nivel final del tramo entre plantas.

- Nota:

Los esfuerzos están referidos a ejes locales del pilar.

Base Cabeza
Dimensión Tramo
Soporte Planta Hipótesis N Mx My Qx Qy T N Mx My Qx Qy T
(cm) (m)
(kN) (kNꞏm) (kNꞏm) (kN) (kN) (kNꞏm) (kN) (kNꞏm) (kNꞏm) (kN) (kN) (kNꞏm)
F1 Baja 40x40 0.00/1.05 Peso propio 12.0 3.9 -1.6 2.9 -0.1 0.0 7.9 0.8 -1.6 2.9 -0.1 0.0
Cargas muertas 31.6 2.2 -6.9 -3.7 -4.8 0.0 31.6 6.0 -1.8 -3.7 -4.8 0.0
Sobrecarga de uso 5.4 1.3 -0.9 0.4 -0.3 0.0 5.4 0.8 -0.6 0.4 -0.3 0.0
V (0º) -0.4 0.6 0.2 1.0 0.2 0.0 -0.4 -0.4 0.0 1.0 0.2 0.0
V (90º) 0.5 -0.4 0.3 -0.6 0.5 0.1 0.5 0.3 -0.2 -0.6 0.5 0.1
V (180º) 0.4 -0.6 -0.2 -1.0 -0.2 0.0 0.4 0.4 -0.0 -1.0 -0.2 0.0
V (270º) -1.5 -1.4 -2.8 -1.4 -3.8 0.0 -1.5 0.2 1.3 -1.4 -3.8 0.0
N1 0.4 0.1 -0.1 0.0 -0.1 0.0 0.4 0.1 -0.0 0.0 -0.1 0.0
Sismo X 1 -3.8 6.9 3.1 10.1 2.9 -0.0 -3.8 -3.7 0.1 10.1 2.9 -0.0
Sismo X 2 -4.1 5.3 1.5 8.1 0.7 0.0 -4.1 -3.2 0.7 8.1 0.7 0.0
Sismo Y 1 5.3 3.5 8.8 3.3 12.3 0.1 5.3 0.0 -4.1 3.3 12.3 0.1
Sismo Y 2 5.9 6.9 12.3 7.7 17.0 -0.1 5.9 -1.2 -5.5 7.7 17.0 -0.1
F2 Baja 40x40 0.00/1.05 Peso propio 12.0 3.9 1.6 2.9 0.1 0.0 7.9 0.8 1.6 2.9 0.1 0.0
Cargas muertas 31.6 2.2 6.9 -3.7 4.8 0.0 31.6 6.0 1.8 -3.7 4.8 0.0
Sobrecarga de uso 5.4 1.3 0.9 0.5 0.3 0.0 5.4 0.8 0.6 0.5 0.3 0.0
V (0º) -0.4 0.6 -0.2 1.0 -0.2 0.0 -0.4 -0.4 -0.0 1.0 -0.2 0.0
V (90º) -0.5 0.4 0.3 0.6 0.5 0.1 -0.5 -0.3 -0.2 0.6 0.5 0.1
V (180º) 0.4 -0.6 0.2 -1.0 0.2 0.0 0.4 0.4 0.0 -1.0 0.2 0.0
V (270º) 1.5 1.4 -2.8 1.4 -3.8 0.0 1.5 -0.2 1.3 1.4 -3.8 0.0
N1 0.4 0.1 0.1 0.0 0.1 0.0 0.4 0.1 0.0 0.0 0.1 0.0
Sismo X 1 -4.1 5.3 -1.5 8.1 -0.7 -0.0 -4.1 -3.2 -0.7 8.1 -0.7 -0.0
Sismo X 2 -3.8 6.9 -3.1 10.1 -2.9 0.0 -3.8 -3.7 -0.1 10.1 -2.9 0.0
Sismo Y 1 -5.3 -3.5 8.8 -3.3 12.3 0.1 -5.3 -0.0 -4.1 -3.3 12.3 0.1
Sismo Y 2 -5.9 -6.9 12.3 -7.7 17.0 -0.1 -5.9 1.2 -5.5 -7.7 17.0 -0.1
F3 Baja 40x40 0.00/1.05 Peso propio 19.0 0.0 -2.1 0.0 -1.1 0.0 14.8 0.0 -1.0 0.0 -1.1 0.0
Cargas muertas 63.8 -0.7 -8.2 -0.7 -10.9 0.0 63.8 0.0 -0.9 -0.7 -3.0 0.0
Sobrecarga de uso 11.4 0.0 -1.3 0.0 -0.8 0.0 11.4 0.0 -0.5 0.0 -0.8 0.0
V (0º) 0.0 1.6 0.0 2.1 0.0 0.0 0.0 -0.6 0.0 2.1 0.0 0.0
V (90º) 0.5 -1.7 1.6 -2.3 1.2 0.1 0.5 0.7 0.3 -2.3 1.2 0.1
V (180º) 0.0 -1.6 0.0 -2.1 0.0 0.0 0.0 0.6 0.0 -2.1 0.0 0.0
V (270º) -0.9 0.0 -3.2 0.0 -2.4 0.0 -0.9 0.0 -0.7 0.0 -2.4 0.0
N1 1.0 0.0 -0.1 0.0 -0.1 0.0 1.0 0.0 -0.0 0.0 -0.1 0.0
Sismo X 1 0.0 16.9 0.0 21.9 0.0 -0.0 0.0 -6.1 0.0 21.9 0.0 -0.0
Sismo X 2 0.0 14.4 0.0 18.5 0.0 0.0 0.0 -5.0 0.0 18.5 0.0 0.0
Sismo Y 1 3.4 -2.7 12.1 -3.7 9.1 0.1 3.4 1.2 2.5 -3.7 9.1 0.1
MOD-A4-E_Is.00

Sismo Y 2 3.4 2.7 12.1 3.7 9.1 -0.1 3.4 -1.2 2.5 3.7 9.1 -0.1
F4 Baja 40x40 0.00/1.05 Peso propio 19.0 0.0 2.1 0.0 1.1 0.0 14.8 0.0 1.0 0.0 1.1 0.0
Cargas muertas 63.8 -0.7 8.2 -0.7 10.9 0.0 63.8 0.0 0.9 -0.7 3.0 0.0
Sobrecarga de uso 11.4 0.0 1.3 0.0 0.8 0.0 11.4 0.0 0.5 0.0 0.8 0.0
V (0º) 0.0 1.6 0.0 2.1 0.0 0.0 0.0 -0.6 0.0 2.1 0.0 0.0

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 69 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Base Cabeza
Dimensión Tramo
Soporte Planta Hipótesis N Mx My Qx Qy T N Mx My Qx Qy T
(cm) (m)
(kN) (kNꞏm) (kNꞏm) (kN) (kN) (kNꞏm) (kN) (kNꞏm) (kNꞏm) (kN) (kN) (kNꞏm)
V (90º) -0.5 1.7 1.6 2.3 1.2 0.1 -0.5 -0.7 0.3 2.3 1.2 0.1
V (180º) 0.0 -1.6 0.0 -2.1 0.0 0.0 0.0 0.6 0.0 -2.1 0.0 0.0
V (270º) 0.9 -0.0 -3.2 -0.0 -2.4 0.0 0.9 0.0 -0.7 -0.0 -2.4 0.0
N1 1.0 0.0 0.1 0.0 0.1 0.0 1.0 0.0 0.0 0.0 0.1 0.0
Sismo X 1 0.0 14.4 0.0 18.5 0.0 -0.0 0.0 -5.0 0.0 18.5 0.0 -0.0
Sismo X 2 0.0 16.9 0.0 21.9 0.0 0.0 0.0 -6.1 0.0 21.9 0.0 0.0
Sismo Y 1 -3.4 2.7 12.1 3.7 9.1 0.1 -3.4 -1.2 2.5 3.7 9.1 0.1
Sismo Y 2 -3.4 -2.7 12.1 -3.7 9.1 -0.1 -3.4 1.2 2.5 -3.7 9.1 -0.1
F5 Baja 40x40 0.00/1.05 Peso propio 12.0 -3.9 -1.6 -2.9 -0.1 0.0 7.9 -0.8 -1.6 -2.9 -0.1 0.0
Cargas muertas 31.6 -1.2 -7.0 4.4 -4.9 0.0 31.6 -5.8 -1.9 4.4 -4.9 0.0
Sobrecarga de uso 5.4 -1.3 -0.9 -0.4 -0.3 0.0 5.4 -0.8 -0.6 -0.4 -0.3 0.0
V (0º) 0.4 0.6 -0.2 1.0 -0.2 0.0 0.4 -0.4 -0.0 1.0 -0.2 0.0
V (90º) 0.9 -1.7 2.5 -2.1 3.3 0.1 0.9 0.4 -1.1 -2.1 3.3 0.1
V (180º) -0.4 -0.6 0.2 -1.0 0.2 0.0 -0.4 0.4 0.0 -1.0 0.2 0.0
V (270º) -1.5 1.4 -2.8 1.4 -3.8 0.0 -1.5 -0.2 1.3 1.4 -3.8 0.0
N1 0.4 -0.1 -0.1 -0.0 -0.1 0.0 0.4 -0.1 -0.0 -0.0 -0.1 0.0
Sismo X 1 3.8 6.9 -3.1 10.1 -2.9 -0.0 3.8 -3.7 -0.1 10.1 -2.9 -0.0
Sismo X 2 4.1 5.3 -1.5 8.1 -0.7 0.0 4.1 -3.2 -0.7 8.1 -0.7 0.0
Sismo Y 1 5.9 -6.9 12.3 -7.7 17.0 0.1 5.9 1.2 -5.5 -7.7 17.0 0.1
Sismo Y 2 5.3 -3.5 8.8 -3.3 12.3 -0.1 5.3 -0.0 -4.1 -3.3 12.3 -0.1
F6 Baja 40x40 0.00/1.05 Peso propio 12.0 -3.9 1.6 -2.9 0.1 0.0 7.9 -0.8 1.6 -2.9 0.1 0.0
Cargas muertas 31.5 -1.2 7.0 4.4 4.9 0.0 31.5 -5.8 1.8 4.4 4.9 0.0
Sobrecarga de uso 5.4 -1.3 0.9 -0.4 0.3 0.0 5.4 -0.8 0.6 -0.4 0.3 0.0
V (0º) 0.4 0.6 0.2 1.0 0.2 0.0 0.4 -0.4 0.0 1.0 0.2 0.0
V (90º) -0.9 1.7 2.5 2.1 3.3 0.1 -0.9 -0.4 -1.1 2.1 3.3 0.1
V (180º) -0.4 -0.6 -0.2 -1.0 -0.2 0.0 -0.4 0.4 -0.0 -1.0 -0.2 0.0
V (270º) 1.5 -1.4 -2.8 -1.4 -3.8 0.0 1.5 0.2 1.3 -1.4 -3.8 0.0
N1 0.4 -0.1 0.1 -0.0 0.1 0.0 0.4 -0.1 0.0 -0.0 0.1 0.0
Sismo X 1 4.1 5.3 1.5 8.1 0.7 -0.0 4.1 -3.2 0.7 8.1 0.7 -0.0
Sismo X 2 3.8 6.9 3.1 10.1 2.9 0.0 3.8 -3.7 0.1 10.1 2.9 0.0
Sismo Y 1 -5.9 6.9 12.3 7.7 17.0 0.1 -5.9 -1.2 -5.5 7.7 17.0 0.1
Sismo Y 2 -5.3 3.5 8.8 3.3 12.3 -0.1 -5.3 0.0 -4.1 3.3 12.3 -0.1

12.13.3 ARRANQUES DE PILARES


- Nota:

Los esfuerzos están referidos a ejes locales del pilar.

Esfuerzos en arranques
Soporte Hipótesis N Mx My Qx Qy T
(kN) (kNꞏm) (kNꞏm) (kN) (kN) (kNꞏm)
F1 Peso propio 12.0 3.9 -1.6 2.9 -0.1 0.0
Cargas muertas 31.6 2.2 -6.9 -3.7 -4.8 0.0
MOD-A4-E_Is.00

Sobrecarga de uso 5.4 1.3 -0.9 0.4 -0.3 0.0


V (0º) -0.4 0.6 0.2 1.0 0.2 0.0
V (90º) 0.5 -0.4 0.3 -0.6 0.5 0.1
V (180º) 0.4 -0.6 -0.2 -1.0 -0.2 0.0

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 70 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Esfuerzos en arranques
Soporte Hipótesis N Mx My Qx Qy T
(kN) (kNꞏm) (kNꞏm) (kN) (kN) (kNꞏm)
V (270º) -1.5 -1.4 -2.8 -1.4 -3.8 0.0
N1 0.4 0.1 -0.1 0.0 -0.1 0.0
Sismo X 1 -3.8 6.9 3.1 10.1 2.9 -0.0
Sismo X 2 -4.1 5.3 1.5 8.1 0.7 0.0
Sismo Y 1 5.3 3.5 8.8 3.3 12.3 0.1
Sismo Y 2 5.9 6.9 12.3 7.7 17.0 -0.1
F2 Peso propio 12.0 3.9 1.6 2.9 0.1 0.0
Cargas muertas 31.6 2.2 6.9 -3.7 4.8 0.0
Sobrecarga de uso 5.4 1.3 0.9 0.5 0.3 0.0
V (0º) -0.4 0.6 -0.2 1.0 -0.2 0.0
V (90º) -0.5 0.4 0.3 0.6 0.5 0.1
V (180º) 0.4 -0.6 0.2 -1.0 0.2 0.0
V (270º) 1.5 1.4 -2.8 1.4 -3.8 0.0
N1 0.4 0.1 0.1 0.0 0.1 0.0
Sismo X 1 -4.1 5.3 -1.5 8.1 -0.7 -0.0
Sismo X 2 -3.8 6.9 -3.1 10.1 -2.9 0.0
Sismo Y 1 -5.3 -3.5 8.8 -3.3 12.3 0.1
Sismo Y 2 -5.9 -6.9 12.3 -7.7 17.0 -0.1
F3 Peso propio 19.0 0.0 -2.1 0.0 -1.1 0.0
Cargas muertas 63.8 -0.7 -8.2 -0.7 -10.9 0.0
Sobrecarga de uso 11.4 0.0 -1.3 0.0 -0.8 0.0
V (0º) 0.0 1.6 0.0 2.1 0.0 0.0
V (90º) 0.5 -1.7 1.6 -2.3 1.2 0.1
V (180º) 0.0 -1.6 0.0 -2.1 0.0 0.0
V (270º) -0.9 0.0 -3.2 0.0 -2.4 0.0
N1 1.0 0.0 -0.1 0.0 -0.1 0.0
Sismo X 1 0.0 16.9 0.0 21.9 0.0 -0.0
Sismo X 2 0.0 14.4 0.0 18.5 0.0 0.0
Sismo Y 1 3.4 -2.7 12.1 -3.7 9.1 0.1
Sismo Y 2 3.4 2.7 12.1 3.7 9.1 -0.1
F4 Peso propio 19.0 0.0 2.1 0.0 1.1 0.0
Cargas muertas 63.8 -0.7 8.2 -0.7 10.9 0.0
Sobrecarga de uso 11.4 0.0 1.3 0.0 0.8 0.0
V (0º) 0.0 1.6 0.0 2.1 0.0 0.0
V (90º) -0.5 1.7 1.6 2.3 1.2 0.1
V (180º) 0.0 -1.6 0.0 -2.1 0.0 0.0
V (270º) 0.9 -0.0 -3.2 -0.0 -2.4 0.0
N1 1.0 0.0 0.1 0.0 0.1 0.0
Sismo X 1 0.0 14.4 0.0 18.5 0.0 -0.0
Sismo X 2 0.0 16.9 0.0 21.9 0.0 0.0
Sismo Y 1 -3.4 2.7 12.1 3.7 9.1 0.1
Sismo Y 2 -3.4 -2.7 12.1 -3.7 9.1 -0.1
MOD-A4-E_Is.00

F5 Peso propio 12.0 -3.9 -1.6 -2.9 -0.1 0.0


Cargas muertas 31.6 -1.2 -7.0 4.4 -4.9 0.0
Sobrecarga de uso 5.4 -1.3 -0.9 -0.4 -0.3 0.0
V (0º) 0.4 0.6 -0.2 1.0 -0.2 0.0

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 71 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Esfuerzos en arranques
Soporte Hipótesis N Mx My Qx Qy T
(kN) (kNꞏm) (kNꞏm) (kN) (kN) (kNꞏm)
V (90º) 0.9 -1.7 2.5 -2.1 3.3 0.1
V (180º) -0.4 -0.6 0.2 -1.0 0.2 0.0
V (270º) -1.5 1.4 -2.8 1.4 -3.8 0.0
N1 0.4 -0.1 -0.1 -0.0 -0.1 0.0
Sismo X 1 3.8 6.9 -3.1 10.1 -2.9 -0.0
Sismo X 2 4.1 5.3 -1.5 8.1 -0.7 0.0
Sismo Y 1 5.9 -6.9 12.3 -7.7 17.0 0.1
Sismo Y 2 5.3 -3.5 8.8 -3.3 12.3 -0.1
F6 Peso propio 12.0 -3.9 1.6 -2.9 0.1 0.0
Cargas muertas 31.5 -1.2 7.0 4.4 4.9 0.0
Sobrecarga de uso 5.4 -1.3 0.9 -0.4 0.3 0.0
V (0º) 0.4 0.6 0.2 1.0 0.2 0.0
V (90º) -0.9 1.7 2.5 2.1 3.3 0.1
V (180º) -0.4 -0.6 -0.2 -1.0 -0.2 0.0
V (270º) 1.5 -1.4 -2.8 -1.4 -3.8 0.0
N1 0.4 -0.1 0.1 -0.0 0.1 0.0
Sismo X 1 4.1 5.3 1.5 8.1 0.7 -0.0
Sismo X 2 3.8 6.9 3.1 10.1 2.9 0.0
Sismo Y 1 -5.9 6.9 12.3 7.7 17.0 0.1
Sismo Y 2 -5.3 3.5 8.8 3.3 12.3 -0.1

12.13.4 COMPROBACIÓN E.L.U. PILARES


12.13.4.1 NOTACIÓN (PILARES)

En las tablas de comprobación de pilares de acero no se muestran las comprobaciones con coeficiente
de aprovechamiento inferior al 10%.
Disp.: Disposiciones relativas a las armaduras
Arm.: Armadura mínima y máxima
Q: Estado límite de agotamiento frente a cortante
N,M: Estado límite de agotamiento frente a solicitaciones normales
Sism.: Criterios de diseño por sismo
Cap.: Diseño por capacidad
12.13.4.2 PILARES
F1
Sección de hormigón
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Sism. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kNꞏm) (kNꞏm) (kN) (kN)
MOD-A4-E_Is.00

G, Q, N, S(3) Q S. 42.0 3.3 10.3 -11.5 -29.8


Cabeza Cumple Cumple 17.7 11.7 Cumple Cumple 17.7 Cumple
G, Q, N, S(4) N,M S. 58.5 -12.1 7.0 10.1 17.8
(5)
Baja (0 - 1.35 m) 40x40 G, S Q S. 27.4 4.6 7.8 -11.5 -28.2
0.525 m Cumple Cumple 40.0 11.7 Cumple Cumple 40.0 Cumple
G, Q, N, S(4) N,M S. 58.5 -12.1 7.0 10.1 17.8
0.525 m Cumple Cumple 44.3 21.6 Cumple Cumple 44.3 G, Q, N, S(3) Q S. 46.9 -28.0 -1.7 -11.5 -29.8 Cumple

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 72 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Sección de hormigón
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Sism. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kNꞏm) (kNꞏm) (kN) (kN)
G, N, S(6) N,M S. 44.2 -27.5 -2.4 -11.7 -29.6
G, Q, N, S(3) Q S. 46.9 -28.0 -1.7 -11.5 -29.8
Pie Cumple Cumple 17.7 21.6 Cumple Cumple 21.6 Cumple
G, N, S(6) N,M S. 44.2 -27.5 -2.4 -11.7 -29.6
Cimentación 40x40 Arranque N.P.(1) N.P.(1) N.P.(2) 21.6 N.P.(1) Cumple 21.6 G, N, S(6) N,M S. 44.2 -27.5 -2.4 -11.7 -29.6 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1-1.4ꞏSY2
(4)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1+1.4ꞏSY2
(5)
0.9ꞏPP+0.9ꞏCM-1.4ꞏSY2
(6)
1.2ꞏPP+1.2ꞏCM+0.2ꞏN1-1.4ꞏSY2

F2
Sección de hormigón
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Sism. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kNꞏm) (kNꞏm) (kN) (kN)
G, Q, N, S(3) Q S. 42.0 -3.3 10.3 -11.4 29.8
Cabeza Cumple Cumple 17.7 11.7 Cumple Cumple 17.7 Cumple
G, Q, N, S(4) N,M S. 58.5 12.1 7.0 10.1 -17.8
G, S(5) Q S. 27.4 -4.6 7.8 -11.4 28.2
0.525 m Cumple Cumple 40.0 11.7 Cumple Cumple 40.0 Cumple
G, Q, N, S(4) N,M S. 58.5 12.1 7.0 10.1 -17.8
Baja (0 - 1.35 m) 40x40 (3)
G, Q, N, S Q S. 46.9 28.0 -1.7 -11.4 29.8
0.525 m Cumple Cumple 44.4 21.6 Cumple Cumple 44.4 Cumple
G, N, S(6) N,M S. 44.3 27.5 -2.4 -11.7 29.6
G, Q, N, S(3) Q S. 46.9 28.0 -1.7 -11.4 29.8
Pie Cumple Cumple 17.7 21.6 Cumple Cumple 21.6 Cumple
G, N, S(6) N,M S. 44.3 27.5 -2.4 -11.7 29.6
(1) (1) (2) (1) (6)
Cimentación 40x40 Arranque N.P. N.P. N.P. 21.6 N.P. Cumple 21.6 G, N, S N,M S. 44.3 27.5 -2.4 -11.7 29.6 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1+1.4ꞏSY2
(4)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1-1.4ꞏSY2
(5)
0.9ꞏPP+0.9ꞏCM+1.4ꞏSY2
(6)
1.2ꞏPP+1.2ꞏCM+0.2ꞏN1+1.4ꞏSY2

F3
Sección de hormigón
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Sism. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kNꞏm) (kNꞏm) (kN) (kN)
Cabeza Cumple Cumple 12.1 8.5 Cumple Cumple 12.1 G, Q, N, S(3) Q S.,N,M S. 100.3 -2.6 8.6 -31.5 -5.4 Cumple
0.525 m Cumple Cumple 30.4 13.1 Cumple Cumple 30.4 G, Q, N, S(4) Q S.,N,M S. 97.9 -16.8 -1.5 -6.0 -22.8 Cumple
Baja (0 - 1.35 m) 40x40
G, Q, V, N(5) Q 104.1 -18.2 -0.8 -0.8 -18.7
Pie Cumple Cumple 24.6 22.9 Cumple Cumple 24.6 Cumple
G, Q, N, S(3) N,M S. 105.2 -13.1 -24.5 -31.5 -14.8
(1) (1) (2) (1) (3)
Cimentación 40x40 Arranque N.P. N.P. N.P. 22.9 N.P. Cumple 22.9 G, Q, N, S N,M S. 105.2 -13.1 -24.5 -31.5 -14.8 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1-1.4ꞏSX1
(4)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1-1.4ꞏSY2
(5)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+1.6ꞏV(270º)+0.5ꞏN1

F4
Sección de hormigón
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Sism. Cap. Naturaleza Comp.
MOD-A4-E_Is.00

(%) (%) (%) (kN) (kNꞏm) (kNꞏm) (kN) (kN)


Cabeza Cumple Cumple 12.2 8.5 Cumple Cumple 12.2 G, Q, N, S(3) Q S.,N,M S. 100.3 2.5 8.6 -31.6 5.3 Cumple
0.525 m Cumple Cumple 30.4 13.1 Cumple Cumple 30.4 G, Q, N, S(4) Q S.,N,M S. 97.9 16.8 -1.5 -6.0 22.8 Cumple
Baja (0 - 1.35 m) 40x40
G, Q, V, N(5) Q 104.8 15.7 1.8 2.8 16.7
Pie Cumple Cumple 13.6 22.9 Cumple Cumple 22.9 Cumple
G, Q, N, S(3) N,M S. 105.2 13.1 -24.6 -31.6 14.8
Cimentación 40x40 Arranque N.P.(1) N.P.(1) N.P.(2) 22.9 N.P.(1) Cumple 22.9 G, Q, N, S(3) N,M S. 105.2 13.1 -24.6 -31.6 14.8 Cumple

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 73 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Sección de hormigón
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Sism. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kNꞏm) (kNꞏm) (kN) (kN)
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1-1.4ꞏSX2
(4)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1+1.4ꞏSY2
(5)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+1.6ꞏV(90º)+0.5ꞏN1

F5
Sección de hormigón
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Sism. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kNꞏm) (kNꞏm) (kN) (kN)
G, Q, N, S(3) Q S. 41.9 3.3 -10.0 12.3 -29.9
Cabeza Cumple Cumple 17.9 11.6 Cumple Cumple 17.9 Cumple
G, Q, N, S(4) N,M S. 58.4 -12.1 -6.7 -9.2 17.7
G, S(5) Q S. 27.3 4.6 -7.6 12.1 -28.2
0.525 m Cumple Cumple 40.4 11.6 Cumple Cumple 40.4 Cumple
G, Q, N, S(4) N,M S. 58.4 -12.1 -6.7 -9.2 17.7
Baja (0 - 1.35 m) 40x40 (3)
G, Q, N, S Q S. 46.9 -28.1 2.9 12.3 -29.9
0.525 m Cumple Cumple 44.7 22.1 Cumple Cumple 44.7 Cumple
G, N, S(6) N,M S. 44.2 -27.6 3.5 12.5 -29.7
G, Q, N, S(3) Q S. 46.9 -28.1 2.9 12.3 -29.9
Pie Cumple Cumple 17.9 22.1 Cumple Cumple 22.1 Cumple
G, N, S(6) N,M S. 44.2 -27.6 3.5 12.5 -29.7
Cimentación 40x40 Arranque N.P.(1) N.P.(1) N.P.(2) 22.1 N.P.(1) Cumple 22.1 G, N, S(6) N,M S. 44.2 -27.6 3.5 12.5 -29.7 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1-1.4ꞏSY1
(4)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1+1.4ꞏSY1
(5)
0.9ꞏPP+0.9ꞏCM-1.4ꞏSY1
(6)
1.2ꞏPP+1.2ꞏCM+0.2ꞏN1-1.4ꞏSY1

F6
Sección de hormigón
Comprobaciones Esfuerzos pésimos
Dimensión
Tramo Posición Q N,M Aprov. N Mxx Myy Qx Qy Estado
(cm) Disp. Arm. Sism. Cap. Naturaleza Comp.
(%) (%) (%) (kN) (kNꞏm) (kNꞏm) (kN) (kN)
G, Q, N, S(3) Q S. 41.9 -3.3 -10.0 12.3 29.9
Cabeza Cumple Cumple 17.9 11.6 Cumple Cumple 17.9 Cumple
G, Q, N, S(4) N,M S. 58.3 12.1 -6.7 -9.3 -17.6
G, S(5) Q S. 27.3 -4.6 -7.6 12.1 28.3
0.525 m Cumple Cumple 40.4 11.6 Cumple Cumple 40.4 Cumple
G, Q, N, S(4) N,M S. 58.3 12.1 -6.7 -9.3 -17.6
Baja (0 - 1.35 m) 40x40
G, Q, N, S(3) Q S. 46.8 28.1 2.9 12.3 29.9
0.525 m Cumple Cumple 44.7 22.1 Cumple Cumple 44.7 Cumple
G, N, S(6) N,M S. 44.1 27.7 3.5 12.5 29.8
(3)
G, Q, N, S Q S. 46.8 28.1 2.9 12.3 29.9
Pie Cumple Cumple 17.9 22.1 Cumple Cumple 22.1 Cumple
G, N, S(6) N,M S. 44.1 27.7 3.5 12.5 29.8
Cimentación 40x40 Arranque N.P.(1) N.P.(1) N.P.(2) 22.1 N.P.(1) Cumple 22.1 G, N, S(6) N,M S. 44.1 27.7 3.5 12.5 29.8 Cumple
Notas:
(1)
La comprobación no procede
(2)
La comprobación no procede, ya que no hay esfuerzo cortante.
(3)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1+1.4ꞏSY1
(4)
1.2ꞏPP+1.2ꞏCM+0.5ꞏQa+0.2ꞏN1-1.4ꞏSY1
(5)
0.9ꞏPP+0.9ꞏCM+1.4ꞏSY1
(6)
1.2ꞏPP+1.2ꞏCM+0.2ꞏN1+1.4ꞏSY1
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 74 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.13.5 SUMATORIO DE ESFUERZOS DE PILARES, PANTALLAS Y MUROS POR HIPÓTESIS Y


PLANTA
- Sólo se tienen en cuenta los esfuerzos de pilares, muros y pantallas, por lo que si la obra tiene
vigas con vinculación exterior, vigas inclinadas, diagonales o estructuras 3D integradas, los
esfuerzos de dichos elementos no se muestran en el siguiente listado.
- Este listado es de utilidad para conocer las cargas actuantes por encima de la cota de la base
de los soportes sobre una planta, por lo que para casos tales como pilares apeados
traccionados, los esfuerzos de dichos pilares tendrán la influencia no sólo de las cargas por
encima sino también la de las cargas que recibe de plantas inferiores.

12.13.5.1 RESUMIDO

Valores referidos al origen (X=0.00, Y=0.00)


Cota N Mx My Qx Qy T
Planta Hipótesis
(m) (kN) (kNꞏm) (kNꞏm) (kN) (kN) (kNꞏm)
Cimentación 0.00 Peso propio 86.0 258.8 109.9 0.0 0.0 0.0
Cargas muertas 254.0 764.4 324.4 0.0 0.0 0.0
Sobrecarga de uso 44.3 133.2 56.5 0.0 0.0 0.0
V (0º) 0.0 10.9 0.0 8.1 0.0 -10.3
V (90º) 0.0 0.0 13.6 0.0 10.1 60.5
V (180º) 0.0 -10.9 0.0 -8.1 0.0 10.3
V (270º) 0.0 0.0 -27.1 0.0 -20.1 -60.5
N1 3.7 11.1 4.7 0.0 0.0 0.0
Sismo X 1 0.0 103.7 0.0 76.8 0.0 -120.8
Sismo X 2 0.0 103.7 0.0 76.8 0.0 -75.4
Sismo Y 1 0.0 0.0 103.7 0.0 76.8 280.4
Sismo Y 2 0.0 0.0 103.7 0.0 76.8 181.8

12.13.6 DESPLAZAMIENTO DE PILARES


12.13.6.1 TABLA DESPLAZAMIENTO DE PILARES

Situaciones persistentes o transitorias


Cota Desp. X Desp. Y Desp. Z
Pilar Planta
(m) (mm) (mm) (mm)
F1 Baja 1.20 0.31 -0.80 -9.20
Cimentación 0.00 0.00 0.00 -9.20
F2 Baja 1.20 0.31 -0.80 -9.56
Cimentación 0.00 0.00 0.00 -9.56
F3 Baja 1.20 0.31 -0.80 -9.79
MOD-A4-E_Is.00

Cimentación 0.00 0.00 0.00 -9.77


F4 Baja 1.20 0.31 -0.80 -10.12
Cimentación 0.00 0.00 0.00 -10.10
F5 Baja 1.20 0.31 -0.80 -10.24

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 75 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Situaciones persistentes o transitorias


Cota Desp. X Desp. Y Desp. Z
Pilar Planta
(m) (mm) (mm) (mm)
Cimentación 0.00 0.00 0.00 -10.24
F6 Baja 1.20 0.31 -0.80 -10.57
Cimentación 0.00 0.00 0.00 -10.56

Situaciones sísmicas
Cota Desp. X Desp. Y Desp. Z
Pilar Planta
(m) (mm) (mm) (mm)
F1 Baja 1.20 1.06 3.15 -11.58
Cimentación 0.00 0.00 0.00 -11.57
F2 Baja 1.20 1.06 3.15 -11.57
Cimentación 0.00 0.00 0.00 -11.56
F3 Baja 1.20 1.06 3.08 -12.03
Cimentación 0.00 0.00 0.00 -12.01
F4 Baja 1.20 1.06 3.08 -12.02
Cimentación 0.00 0.00 0.00 -12.00
F5 Baja 1.20 1.06 3.15 -12.58
Cimentación 0.00 0.00 0.00 -12.57
F6 Baja 1.20 1.06 3.15 -12.57
Cimentación 0.00 0.00 0.00 -12.57

12.13.7 COMPROBACIONES DE PUNZONAMIENTO


F1
Perímetro crítico: 1050 mm
Canto útil de la losa: 25 cm
Tipo Comprobación Resultado Estado
Elementos sin refuerzo para cortante
Perímetro crítico 0.30 MPa  1.10 MPa Cumple
(Combinaciones persistentes)
Elementos sin refuerzo para cortante
Perímetro crítico (Combinaciones sísmicas y 0.63 MPa  0.88 MPa Cumple
accidentales)

F2
Perímetro crítico: 1050 mm
Canto útil de la losa: 25 cm
Tipo Comprobación Resultado Estado
Elementos sin refuerzo para cortante
MOD-A4-E_Is.00

Perímetro crítico 0.33 MPa  1.10 MPa Cumple


(Combinaciones persistentes)
Elementos sin refuerzo para cortante
Perímetro crítico 0.63 MPa  0.88 MPa Cumple
(Combinaciones sísmicas y accidentales)

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 76 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

F3
Perímetro crítico: 1700 mm
Canto útil de la losa: 25 cm
Tipo Comprobación Resultado Estado
Elementos sin refuerzo para cortante
Perímetro crítico 0.32 MPa  1.10 MPa Cumple
(Combinaciones persistentes)
Elementos sin refuerzo para cortante
Perímetro crítico 0.47 MPa  0.88 MPa Cumple
(Combinaciones sísmicas y accidentales)

F4
Perímetro crítico: 1700 mm
Canto útil de la losa: 25 cm
Tipo Comprobación Resultado Estado
Elementos sin refuerzo para cortante
Perímetro crítico 0.33 MPa  1.10 MPa Cumple
(Combinaciones persistentes)
Elementos sin refuerzo para cortante
Perímetro crítico 0.47 MPa  0.88 MPa Cumple
(Combinaciones sísmicas y accidentales)

F5
Perímetro crítico: 1050 mm
Canto útil de la losa: 25 cm
Tipo Comprobación Resultado Estado
Elementos sin refuerzo para cortante
Perímetro crítico 0.33 MPa  1.10 MPa Cumple
(Combinaciones persistentes)
Elementos sin refuerzo para cortante
Perímetro crítico 0.63 MPa  0.88 MPa Cumple
(Combinaciones sísmicas y accidentales)

F6
Perímetro crítico: 1050 mm
Canto útil de la losa: 25 cm
Tipo Comprobación Resultado Estado
Elementos sin refuerzo para cortante
Perímetro crítico 0.33 MPa  1.10 MPa Cumple
MOD-A4-E_Is.00

(Combinaciones persistentes)
Elementos sin refuerzo para cortante
Perímetro crítico 0.63 MPa  0.88 MPa Cumple
(Combinaciones sísmicas y accidentales)

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 77 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.14 VIGAS DE ATADO EN CABEZA DE PILARES


12.14.1 COMPROBACIÓN E.L.U. VIGAS DE ATADO
COMPROBACIONES DE RESISTENCIA (NCH430.OF2008-DECRETO 60/2011)
Vigas Estado
Disp. Arm. Q Q S. N,M N,M S. Tc Tst Tsl TNMx TVx TVy TVXst TVYst T,Disp.sl T,Disp.st T,Geom.sl T,Arm.st Sism. Cap. H
'0.000 m' '0.000 m' '2.341 m' '2.341 m' '0.000 m' CUMPLE
V-101: F1 - F3 Cumple Cumple N.P.(1) N.P.(1) N.P.(1) N.P.(2) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) Cumple
 = 5.6  = 13.4  = 12.1  = 27.4 Cumple  = 27.4
'2.341 m' '2.341 m' '0.000 m' '0.000 m' '0.000 m' CUMPLE
V-102: F3 - F5 Cumple Cumple N.P.(1) N.P.(1) N.P.(1) N.P.(2) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) Cumple
 = 5.6  = 13.3  = 13.2  = 28.0 Cumple  = 28.0
'0.000 m' '0.000 m' '2.341 m' '2.341 m' '0.000 m' CUMPLE
V-103: F2 - F4 Cumple Cumple N.P.(1) N.P.(1) N.P.(1) N.P.(2) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) Cumple
 = 5.7  = 13.4  = 12.1  = 27.4 Cumple  = 27.4
'2.341 m' '2.341 m' '0.000 m' '0.000 m' '0.000 m' CUMPLE
V-104: F4 - F6 Cumple Cumple N.P.(1) N.P.(1) N.P.(1) N.P.(2) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) Cumple
 = 5.6  = 13.3  = 12.7  = 28.0 Cumple  = 28.0
'0.539 m' '1.886 m' '1.616 m' '0.000 m' '0.000 m' CUMPLE
V-105: F2 - F1 Cumple Cumple N.P.(1) N.P.(1) N.P.(1) N.P.(2) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) Cumple
 = 2.9  = 13.3  = 10.2  = 31.4 Cumple  = 31.4
'0.539 m' '1.886 m' '1.616 m' '0.000 m' '0.000 m' CUMPLE
V-106: F6 - F5 Cumple Cumple N.P.(1) N.P.(1) N.P.(1) N.P.(2) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) Cumple
 = 2.9  = 13.3  = 10.3  = 31.4 Cumple  = 31.4
Notación:
Disp.: Disposiciones relativas a las armaduras
Arm.: Armadura mínima y máxima
Q: Estado límite de agotamiento frente a cortante (combinaciones no sísmicas)
Q S.: Estado límite de agotamiento frente a cortante (combinaciones sísmicas)
N,M: Estado límite de agotamiento frente a solicitaciones normales (combinaciones no sísmicas)
N,M S.: Estado límite de agotamiento frente a solicitaciones normales (combinaciones sísmicas)
Tc: Estado límite de agotamiento por torsión. Compresión oblicua.
Tst: Estado límite de agotamiento por torsión. Tracción en el alma.
Tsl: Estado límite de agotamiento por torsión. Tracción en las armaduras longitudinales.
TNMx: Estado límite de agotamiento por torsión. Interacción entre torsión y esfuerzos normales. Flexión alrededor del eje X.
TVx: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje X. Compresión oblicua
TVy: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje Y. Compresión oblicua
TVXst: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje X. Tracción en el alma.
TVYst: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje Y. Tracción en el alma.
T,Disp.sl: Estado límite de agotamiento por torsión. Separación entre las barras de la armadura longitudinal.
T,Disp.st: Estado límite de agotamiento por torsión. Separación entre las barras de la armadura transversal.
T,Geom.sl: Estado límite de agotamiento por torsión. Diámetro mínimo de la armadura longitudinal.
T,Arm.st: Estado límite de agotamiento por torsión. Cuantía mínima de estribos cerrados.
Sism.: Criterios de diseño por sismo
Cap. H: Cortante de diseño para vigas.
x: Distancia al origen de la barra
: Coeficiente de aprovechamiento (%)
N.P.: No procede
Comprobaciones que no proceden (N.P.):
(1) La comprobación del estado límite de agotamiento por torsión no procede, ya que no hay momento torsor.
(2) La comprobación no procede, ya que no hay interacción entre torsión y esfuerzos normales.

COMPROBACIONES DE FISURACIÓN (NCH430.OF2008-DECRETO 60/2011)


Vigas Estado
sC,sup. sC,Lat.Der. sC,inf. sC,Lat.Izq.
x: 2.609 m (1) x: 0.652 m
V-101: F1 - F3 N.P. N.P.(1) CUMPLE
Cumple Cumple
x: 0 m x: 1.957 m
V-102: F3 - F5 N.P.(1) N.P.(1) CUMPLE
Cumple Cumple
x: 2.609 m x: 0.652 m
V-103: F2 - F4 N.P.(1) N.P.(1) CUMPLE
Cumple Cumple
x: 0 m x: 1.957 m
V-104: F4 - F6 N.P.(1) N.P.(1) CUMPLE
Cumple Cumple
x: 1.077 m
V-105: F2 - F1 N.P.(1) N.P.(1) N.P.(1) CUMPLE
Cumple
x: 1.077 m
V-106: F6 - F5 N.P.(1) N.P.(1) N.P.(1) CUMPLE
Cumple
Notación:
sC,sup.: Comprobación de la separación máxima entre barras: Cara superior
sC,Lat.Der.: Comprobación de la separación máxima entre barras: Cara lateral derecha
sC,inf.: Comprobación de la separación máxima entre barras: Cara inferior
sC,Lat.Izq.: Comprobación de la separación máxima entre barras: Cara lateral izquierda
x: Distancia al origen de la barra
: Coeficiente de aprovechamiento (%)
N.P.: No procede
Comprobaciones que no proceden (N.P.):
MOD-A4-E_Is.00

(1) La comprobación no procede, ya que no hay ninguna armadura traccionada.

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 78 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Comprobaciones de flecha
Activa
(Característica)
Vigas Estado
fA,max  fA,lim
fA,lim= L/480
fA,max: 0.12 mm
V-101: F1 - F3 CUMPLE
fA,lim: 5.44 mm
f : 0.12 mm
V-102: F3 - F5 A,max CUMPLE
fA,lim: 5.44 mm
f : 0.12 mm
V-103: F2 - F4 A,max CUMPLE
fA,lim: 5.44 mm
f : 0.12 mm
V-104: F4 - F6 A,max CUMPLE
fA,lim: 5.44 mm
f : 0.09 mm
V-105: F2 - F1 A,max CUMPLE
fA,lim: 4.49 mm
f : 0.09 mm
V-106: F6 - F5 A,max CUMPLE
fA,lim: 4.49 mm
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 79 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

12.14.2 ARMADO DE VIGAS DE ATADO


Pórtico 1

Pórtico 1 Tramo: V-101 Tramo: V-102


Sección 50x30 50x30
Zona 1/3L 2/3L 3/3L 1/3L 2/3L 3/3L
Momento mín. [kNꞏm] -1.12 -- -5.10 -5.56 -- -1.09
x [m] 0.00 -- 2.61 0.00 -- 2.61
Momento máx. [kNꞏm] 4.99 4.91 1.39 1.22 4.83 4.99
Situaciones x [m] 0.65 0.98 1.96 0.65 1.63 1.96
persistentes o Cortante mín. [kN] -0.18 -5.16 -11.04 -- -0.06 -48.80
MOD-A4-E_Is.00

transitorias x [m] 0.65 1.63 2.61 -- 1.63 2.61


Cortante máx. [kN] 48.89 0.13 -- 11.14 5.39 0.73
x [m] 0.00 0.98 -- 0.00 0.98 1.96
Torsor mín. [kN] -- -- -- -- -- --

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 80 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Pórtico 1 Tramo: V-101 Tramo: V-102


Sección 50x30 50x30
Zona 1/3L 2/3L 3/3L 1/3L 2/3L 3/3L
x [m] -- -- -- -- -- --
Torsor máx. [kN] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Momento mín. [kNꞏm] -8.46 -- -11.56 -11.79 -- -8.43
x [m] 0.00 -- 2.61 0.00 -- 2.61
Momento máx. [kNꞏm] 10.00 6.45 5.16 4.98 6.37 9.98
x [m] 0.33 0.98 2.61 0.00 1.63 2.28
Cortante mín. [kN] -5.62 -10.24 -15.05 -2.21 -5.45 -49.95
Situaciones x [m] 0.65 1.63 2.61 0.65 1.63 2.61
sísmicas Cortante máx. [kN] 50.04 5.52 2.28 15.15 10.34 5.69
x [m] 0.00 0.98 1.96 0.00 0.98 1.96
Torsor mín. [kN] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Torsor máx. [kN] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Real 4.52 4.52 4.52 4.52 4.52 4.52
Área Sup. [cm²]
Nec. 4.52 4.52 4.52 4.52 4.52 4.52
Real 4.52 4.52 4.52 4.52 4.52 4.52
Área Inf. [cm²]
Nec. 4.52 4.52 4.52 4.52 4.52 4.52
Real 14.37 7.74 14.37 14.37 7.74 14.37
Área Transv. [cm²/m]
Nec. 8.13 4.25 8.13 8.13 4.25 8.13
F. Activa 0.12 mm, L/21083 (L: 2.61 m) 0.12 mm, L/22023 (L: 2.61 m)
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 81 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

2.2. Pórtico 2

Pórtico 2 Tramo: V-103 Tramo: V-104


Sección 50x30 50x30
Zona 1/3L 2/3L 3/3L 1/3L 2/3L 3/3L
Momento mín. [kNꞏm] -1.06 -- -5.10 -5.36 -- -1.73
x [m] 0.00 -- 2.61 0.00 -- 2.61
Momento máx. [kNꞏm] 4.98 4.90 1.33 1.41 4.83 4.95
Situaciones x [m] 0.65 0.98 1.96 0.65 1.63 1.96
persistentes o Cortante mín. [kN] -0.22 -5.15 -11.04 -- -0.49 -48.79
MOD-A4-E_Is.00

transitorias x [m] 0.65 1.63 2.61 -- 1.63 2.61


Cortante máx. [kN] 48.90 0.09 -- 11.15 5.27 0.31
x [m] 0.00 0.98 -- 0.00 0.98 1.96
Torsor mín. [kN] -- -- -- -- -- --

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 82 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Pórtico 2 Tramo: V-103 Tramo: V-104


Sección 50x30 50x30
Zona 1/3L 2/3L 3/3L 1/3L 2/3L 3/3L
x [m] -- -- -- -- -- --
Torsor máx. [kN] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Momento mín. [kNꞏm] -8.43 -- -11.55 -11.81 -- -8.42
x [m] 0.00 -- 2.61 0.00 -- 2.61
Momento máx. [kNꞏm] 9.98 6.44 5.16 4.97 6.37 9.99
x [m] 0.33 0.98 2.61 0.00 1.63 2.28
Cortante mín. [kN] -5.61 -10.24 -15.04 -2.20 -5.44 -49.93
Situaciones x [m] 0.65 1.63 2.61 0.65 1.63 2.61
sísmicas Cortante máx. [kN] 50.05 5.53 2.29 15.16 10.35 5.70
x [m] 0.00 0.98 1.96 0.00 0.98 1.96
Torsor mín. [kN] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Torsor máx. [kN] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Real 4.52 4.52 4.52 4.52 4.52 4.52
Área Sup. [cm²]
Nec. 4.52 4.52 4.52 4.52 4.52 4.52
Real 4.52 4.52 4.52 4.52 4.52 4.52
Área Inf. [cm²]
Nec. 4.52 4.52 4.52 4.52 4.52 4.52
Real 14.37 7.74 14.37 14.37 7.74 14.37
Área Transv. [cm²/m]
Nec. 8.13 4.25 8.13 8.13 4.25 8.13
F. Activa 0.12 mm, L/21144 (L: 2.61 m) 0.12 mm, L/22021 (L: 2.61 m)
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 83 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

2.3. Pórtico 3

Pórtico 3 Tramo: V-105


Sección 50x30
Zona 1/3L 2/3L 3/3L
Momento mín. [kNꞏm] -2.86 -- --
x [m] 0.00 -- --
Momento máx. [kNꞏm] 3.09 4.03 4.32
Situaciones x [m] 0.54 1.35 1.62
persistentes o Cortante mín. [kN] -- -1.75 -6.48
MOD-A4-E_Is.00

transitorias x [m] -- 1.35 2.15


Cortante máx. [kN] 8.34 4.37 1.27
x [m] 0.00 0.81 1.62
Torsor mín. [kN] -- -- --

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 84 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Pórtico 3 Tramo: V-105


Sección 50x30
Zona 1/3L 2/3L 3/3L
x [m] -- -- --
Torsor máx. [kN] -- -- --
x [m] -- -- --
Momento mín. [kNꞏm] -12.25 -0.95 -12.26
x [m] 0.00 1.35 2.15
Momento máx. [kNꞏm] 13.25 6.38 13.24
x [m] 0.00 0.81 2.15
Cortante mín. [kN] -9.99 -13.10 -17.07
Situaciones x [m] 0.54 1.35 2.15
sísmicas Cortante máx. [kN] 17.06 13.09 9.99
x [m] 0.00 0.81 1.62
Torsor mín. [kN] -- -- --
x [m] -- -- --
Torsor máx. [kN] -- -- --
x [m] -- -- --
Real 4.52 4.52 4.52
Área Sup. [cm²]
Nec. 4.52 4.52 4.52
Real 4.52 4.52 4.52
Área Inf. [cm²]
Nec. 4.52 4.52 4.52
Real 14.37 14.37 14.37
Área Transv. [cm²/m]
Nec. 7.10 4.25 7.10
F. Activa 0.09 mm, L/23498 (L: 2.15 m)
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 85 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

2.4. Pórtico 4

Pórtico 4 Tramo: V-106


Sección 50x30
Zona 1/3L 2/3L 3/3L
Momento mín. [kNꞏm] -2.85 -- -2.40
x [m] 0.00 -- 2.15
Momento máx. [kNꞏm] 4.11 4.04 4.33
Situaciones x [m] 0.54 1.35 1.62
persistentes o Cortante mín. [kN] -0.85 -3.96 -7.93
transitorias
MOD-A4-E_Is.00

x [m] 0.54 1.35 2.15


Cortante máx. [kN] 8.34 4.37 1.26
x [m] 0.00 0.81 1.62
Torsor mín. [kN] -- -- --

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 86 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Pórtico 4 Tramo: V-106


Sección 50x30
Zona 1/3L 2/3L 3/3L
x [m] -- -- --
Torsor máx. [kN] -- -- --
x [m] -- -- --
Momento mín. [kNꞏm] -12.24 -0.94 -12.25
x [m] 0.00 1.35 2.15
Momento máx. [kNꞏm] 13.26 6.39 13.25
x [m] 0.00 0.81 2.15
Cortante mín. [kN] -9.99 -13.10 -17.07
Situaciones x [m] 0.54 1.35 2.15
sísmicas Cortante máx. [kN] 17.06 13.09 9.98
x [m] 0.00 0.81 1.62
Torsor mín. [kN] -- -- --
x [m] -- -- --
Torsor máx. [kN] -- -- --
x [m] -- -- --
Real 4.52 4.52 4.52
Área Sup. [cm²]
Nec. 4.52 4.52 4.52
Real 4.52 4.52 4.52
Área Inf. [cm²]
Nec. 4.52 4.52 4.52
Real 14.37 14.37 14.37
Área Transv. [cm²/m]
Nec. 7.10 4.25 7.10
F. Activa 0.09 mm, L/23354 (L: 2.15 m)
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 87 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

13 ANEJO DE CÁLCULO CONTROL ROOM

Imagen 17 3D Armado de losa de cimentación Control Room

13.1 NORMAS CONSIDERADAS


Hormigón: NCh430.Of2008, Dº60:2011
Aceros conformados: NCh427
Aceros laminados y armados: NCh427
Categoría de uso: General

13.2 ACCIONES CONSIDERADAS

13.2.1 VIENTO
Se ha tenido en cuenta la acción del viento mediante cargas aplicadas en las siguientes hipótesis: 'V
(0º)', 'V (90º)', 'V (180º)' y 'V (270º)'.

13.2.2 SISMO
MOD-A4-E_Is.00

Sin acción de sismo

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 88 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

13.2.3 HIPÓTESIS DE CARGA

Automáticas Peso propio


Cargas muertas
Sobrecarga de uso
Adicionales Referencia Naturaleza
V (0º) Viento
V (90º) Viento
V (180º) Viento
V (270º) Viento
N1 Nieve

13.2.4 LISTADO DE CARGAS

Cargas especiales introducidas (en kN, kN/m y kN/m²)

Grupo Hipótesis Tipo Valor Coordenadas

Cimentación Cargas muertas Superficial 1.17 (3.27,0.13) (3.27,2.28) (0.12,2.28) (0.13,0.13)


Sobrecarga de uso Superficial 4.00 (3.27,0.13) (3.27,2.28) (0.12,2.28) (0.13,0.13)
V (0º) Puntual 3.32 (0.20,0.20)
V (0º) Puntual 3.32 (0.20,2.20)
V (90º) Puntual 4.98 (0.20,0.20)
V (90º) Puntual 4.98 (3.20,0.20)
V (180º) Puntual 3.32 (3.20,2.20)
V (180º) Puntual 3.32 (3.20,0.20)
V (270º) Puntual 4.98 (0.20,2.20)
V (270º) Puntual 4.98 (3.20,2.20)
N1 Superficial 0.25 (3.27,0.13) (3.27,2.28) (0.12,2.28) (0.13,0.13)

13.3 ESTADOS LÍMITE

E.L.U. de rotura. Hormigón NCh430.Of2008, Dº60:2011


E.L.U. de rotura. Hormigón en cimentaciones
Tensiones sobre el terreno Acciones características
Desplazamientos
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 89 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

13.4 SITUACIONES DE PROYECTO


Para las distintas situaciones de proyecto, las combinaciones de acciones se definirán de acuerdo con
los siguientes criterios:


j 1
Gj Gkj  PPk    QiQki
i1

- Donde:

Gk Acción permanente
Pk Acción de pretensado
Qk Acción variable
G Coeficiente parcial de seguridad de las acciones permanentes
P Coeficiente parcial de seguridad de la acción de pretensado
Q,1 Coeficiente parcial de seguridad de la acción variable principal
Q,i Coeficiente parcial de seguridad de las acciones variables de acompañamiento

13.4.1 COEFICIENTES PARCIALES DE SEGURIDAD () Y COEFICIENTES DE COMBINACIÓN ()

Para cada situación de proyecto y estado límite los coeficientes a utilizar serán:
E.L.U. de rotura. Hormigón: NCh430.Of2008, Dº60:2011
E.L.U. de rotura. Hormigón en cimentaciones: NCh430.Of2008, Dº60:2011

(9-1)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.400 1.400
Sobrecarga (Q)
Viento (Q)
Nieve (Q)

(9-2 Lr)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 1.600
Viento (Q)
MOD-A4-E_Is.00

Nieve (Q)

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 90 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

(9-2 S)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 1.600
Viento (Q)
Nieve (Q) 0.000 0.500

(9-3 Lr, L)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
Nieve (Q)

(9-3 S, L)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
Nieve (Q) 1.600 1.600

(9-3 Lr, W)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q)
Viento (Q) 0.000 0.800
Nieve (Q)

(9-3 S, W)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q)
Viento (Q) 0.000 0.800
Nieve (Q) 1.600 1.600
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 91 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

(9-4 Lr)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q) 1.600 1.600
Nieve (Q)

(9-4 S)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q) 1.600 1.600
Nieve (Q) 0.000 0.500

(9-6)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 0.900 0.900
Sobrecarga (Q)
Viento (Q) 0.000 1.600
Nieve (Q)

Tensiones sobre el terreno

Acciones variables sin sismo


Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q) 0.000 1.000
Viento (Q) 0.000 1.000
Nieve (Q) 0.000 1.000

Desplazamientos

Acciones variables sin sismo


Coeficientes parciales de seguridad ()
Favorable Desfavorable
MOD-A4-E_Is.00

Carga permanente (G) 1.000 1.000


Sobrecarga (Q) 0.000 1.000
Viento (Q) 0.000 1.000
Nieve (Q) 0.000 1.000

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 92 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

13.4.2 COMBINACIONES
- Nombres de las hipótesis

PP Peso propio
CM Cargas muertas
Qa Sobrecarga de uso
V (0º) V (0º)
V (90º) V (90º)
V (180º) V (180º)
V (270º) V (270º)
N1 N1

- E.L.U. de rotura. Hormigón


- E.L.U. de rotura. Hormigón en cimentaciones

Comb. PP CM Qa V (0º) V (90º) V (180º) V (270º) N 1


1 1.400 1.400
2 1.200 1.200
3 1.200 1.200 1.600
4 1.200 1.200 1.600 0.500
5 1.200 1.200 1.600
6 1.200 1.200 0.500 1.600
7 1.200 1.200 0.800 1.600
8 1.200 1.200 0.800 1.600
9 1.200 1.200 0.800 1.600
10 1.200 1.200 0.800 1.600
11 1.200 1.200 1.600
12 1.200 1.200 0.500 1.600
13 1.200 1.200 1.600
14 1.200 1.200 0.500 1.600
15 1.200 1.200 1.600
16 1.200 1.200 0.500 1.600
17 1.200 1.200 1.600
18 1.200 1.200 0.500 1.600
19 1.200 1.200 1.600 0.500
20 1.200 1.200 0.500 1.600 0.500
21 1.200 1.200 1.600 0.500
22 1.200 1.200 0.500 1.600 0.500
23 1.200 1.200 1.600 0.500
MOD-A4-E_Is.00

24 1.200 1.200 0.500 1.600 0.500


25 1.200 1.200 1.600 0.500
26 1.200 1.200 0.500 1.600 0.500
27 0.900 0.900
28 0.900 0.900 1.600

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 93 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Comb. PP CM Qa V (0º) V (90º) V (180º) V (270º) N 1


29 0.900 0.900 1.600
30 0.900 0.900 1.600
31 0.900 0.900 1.600

- Tensiones sobre el terreno


- Desplazamientos

Comb. PP CM Qa V (0º) V (90º) V (180º) V (270º) N 1


1 1.000 1.000
2 1.000 1.000 1.000
3 1.000 1.000 1.000
4 1.000 1.000 1.000 1.000
5 1.000 1.000 1.000
6 1.000 1.000 1.000 1.000
7 1.000 1.000 1.000
8 1.000 1.000 1.000 1.000
9 1.000 1.000 1.000
10 1.000 1.000 1.000 1.000
11 1.000 1.000 1.000
12 1.000 1.000 1.000 1.000
13 1.000 1.000 1.000 1.000
14 1.000 1.000 1.000 1.000 1.000
15 1.000 1.000 1.000 1.000
16 1.000 1.000 1.000 1.000 1.000
17 1.000 1.000 1.000 1.000
18 1.000 1.000 1.000 1.000 1.000
19 1.000 1.000 1.000 1.000
20 1.000 1.000 1.000 1.000 1.000

13.5 LOSAS Y ELEMENTOS DE CIMENTACIÓN

Losas cimentación Canto (cm) Módulo balasto (kN/m³) Tensión admisible Tensión admisible
en situaciones en situaciones
persistentes (MPa) accidentales (MPa)
Todas 20 4078.60 0.067 0.089
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 94 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

13.6 MATERIALES UTILIZADOS


13.6.1 HORMIGONES

f'c Tamaño máximo del árido Ec


Elemento Hormigón
(MPa) (mm) (MPa)
Vigas y losas de cimentación H25 20 20 20810

13.6.2 ACEROS POR ELEMENTO Y POSICIÓN


13.6.2.1 ACEROS EN BARRAS

fyk
Elemento Acero s
(MPa)
Todos A-63-42H 412 1.00

13.6.2.2 ACEROS EN PERFILES

Límite elástico Módulo de elasticidad


Tipo de acero para perfiles Acero
(MPa) (GPa)
Acero conformado A37-24ES 235 206
Acero laminado A42-27ES 265 206

13.7 LOSA DE CIMENTACIÓN


13.7.1 ESFUERZOS EN NUDOS DE LA LOSA
13.7.1.1 TABLA DE ESFUERZOS
Cortantes en KN. Momentos en KN x m.

Coord. X y Coord. Y son coordenadas generales. Los esfuerzos están referidos a los ejes locales de
la malla correspondiente.

Esquema malla y coordenadas en programa Cypecad:


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 95 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Imagen 18 Esquema de malla y coordenadas en el programa cálculo Cypecad

Envolventes de esfuerzos mayorados


Cimentación
Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY
0.250 0.450 Máx. 4.6524 1.4568 0.0278 0.3071 2.3242 0.450 0.450 Máx. 3.7741 1.4568 0.3203 0.3071 2.1085
Mín. -0.8946 -0.8581 -0.0648 -0.5915 -0.4053 Mín. -0.9530 -0.8581 -1.5723 -0.5915 -0.4277
Dif. 5.5470 2.3149 0.0926 0.8986 2.7296 Dif. 4.7271 2.3149 1.8926 0.8986 2.5362
0.250 0.700 Máx. 2.0739 1.3124 0.0306 0.5269 1.8319 0.450 0.700 Máx. 1.9281 1.3124 0.3421 0.5269 1.8243
Mín. -0.9722 -0.6950 -0.1193 -1.1552 -0.5364 Mín. -1.0208 -0.6950 -0.9649 -1.1552 -0.5781
Dif. 3.0460 2.0075 0.1500 1.6821 2.3683 Dif. 2.9489 2.0075 1.3071 1.6821 2.4024
0.250 0.950 Máx. 1.1937 1.0942 0.0315 0.6534 1.3958 0.450 0.950 Máx. 1.1828 1.0942 0.3516 0.6534 1.4458
Mín. -1.0007 -0.3447 -0.1046 -1.4836 -0.7434 Mín. -1.0469 -0.3447 -0.6609 -1.4836 -0.7925
Dif. 2.1944 1.4389 0.1361 2.1369 2.1392 Dif. 2.2298 1.4389 1.0125 2.1369 2.2383
0.250 1.200 Máx. 0.8324 0.6967 0.0317 0.6958 1.0427 0.450 1.200 Máx. 0.8300 0.6967 0.3543 0.6958 1.1005
Mín. -1.0081 -0.6570 -0.1019 -1.5869 -1.0146 Mín. -1.0542 -0.6570 -0.5084 -1.5869 -1.0688
Dif. 1.8405 1.3537 0.1336 2.2826 2.0574 Dif. 1.8842 1.3537 0.8627 2.2826 2.1692
0.250 1.450 Máx. 1.1634 0.3447 0.0315 0.6534 0.7682 0.450 1.450 Máx. 1.1437 0.3447 0.3516 0.6534 0.8202
Mín. -1.0007 -1.0541 -0.1046 -1.4836 -1.3655 Mín. -1.0469 -1.0541 -0.6501 -1.4836 -1.4113
Dif. 2.1641 1.3988 0.1361 2.1369 2.1337 Dif. 2.1906 1.3988 1.0018 2.1369 2.2315
0.250 1.700 Máx. 2.0538 0.6950 0.0306 0.5269 0.5573 0.450 1.700 Máx. 1.8979 0.6950 0.3421 0.5269 0.6014
Mín. -0.9722 -1.3124 -0.1201 -1.1552 -1.8011 Mín. -1.0208 -1.3124 -0.9590 -1.1552 -1.7887
Dif. 3.0260 2.0075 0.1507 1.6821 2.3583 Dif. 2.9186 2.0075 1.3012 1.6821 2.3901
MOD-A4-E_Is.00

0.250 1.950 Máx. 4.6452 0.8581 0.0278 0.3071 0.4233 0.450 1.950 Máx. 3.7508 0.8581 0.3203 0.3071 0.4471
Mín. -0.8946 -1.4568 -0.0661 -0.5985 -2.2938 Mín. -0.9530 -1.4568 -1.5731 -0.5985 -2.0739
Dif. 5.5398 2.3149 0.0939 0.9056 2.7171 Dif. 4.7038 2.3149 1.8934 0.9056 2.5210
0.450 0.250 Máx. 3.7741 1.3385 0.3203 0.0289 2.0863 0.450 2.150 Máx. 3.7508 0.8436 0.3203 0.0289 0.3821
Mín. -0.9530 -0.8436 -1.5723 -0.0594 -0.3648 Mín. -0.9530 -1.3385 -1.5731 -0.0618 -2.0541
Dif. 4.7271 2.1821 1.8926 0.0883 2.4511 Dif. 4.7038 2.1821 1.8934 0.0906 2.4361

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 96 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY
0.700 0.250 Máx. 2.4527 0.7340 0.5706 0.0326 1.5607 1.200 1.950 Máx. 1.0837 0.9858 0.8840 0.3581 0.2646
Mín. -0.8857 -0.9300 -2.2663 -0.1115 -0.3392 Mín. -0.4387 -0.6134 -2.9646 -0.2429 -0.7126
Dif. 3.3384 1.6640 2.8369 0.1441 1.8999 Dif. 1.5223 1.5992 3.8486 0.6010 0.9772
0.700 0.450 Máx. 2.4527 0.9306 0.5706 0.3345 1.6492 1.200 2.150 Máx. 1.0837 0.9882 0.8840 0.0481 0.2260
Mín. -0.8857 -0.9320 -2.2663 -0.3990 -0.4060 Mín. -0.4387 -0.3812 -2.9646 -0.0965 -0.6643
Dif. 3.3384 1.8627 2.8369 0.7335 2.0552 Dif. 1.5223 1.3693 3.8486 0.1446 0.8903
0.700 0.700 Máx. 1.5702 1.2389 0.5943 0.5614 1.5078 1.450 0.250 Máx. 1.1131 0.3522 0.9611 0.0519 0.3577
Mín. -0.9340 -0.7433 -1.6830 -0.7422 -0.5374 Mín. -0.7843 -0.9979 -3.1725 -0.0880 -0.1076
Dif. 2.5043 1.9822 2.2773 1.3036 2.0452 Dif. 1.8974 1.3502 4.1336 0.1399 0.4654
0.700 0.950 Máx. 1.0989 1.3293 0.6071 0.6899 1.2540 1.450 0.450 Máx. 1.1131 0.5947 0.9611 0.3627 0.3844
Mín. -0.9541 -0.9261 -1.2640 -0.9940 -0.7206 Mín. -0.7843 -0.9956 -3.1725 -0.1915 -0.1243
Dif. 2.0530 2.2554 1.8712 1.6840 1.9746 Dif. 1.8974 1.5903 4.1336 0.5541 0.5086
0.700 1.200 Máx. 0.8087 1.1748 0.6112 0.7327 0.9855 1.450 0.700 Máx. 1.1321 1.0493 0.9780 0.6086 0.3672
Mín. -0.9602 -1.1455 -0.9825 -1.0807 -0.9498 Mín. -0.8834 -1.3590 -2.6882 -0.3260 -0.1509
Dif. 1.7690 2.3203 1.5937 1.8133 1.9353 Dif. 2.0155 2.4082 3.6662 0.9346 0.5180
0.700 1.450 Máx. 1.0435 0.9470 0.6071 0.6899 0.7509 1.450 0.950 Máx. 1.1200 1.3642 0.9893 0.7473 0.3243
Mín. -0.9541 -1.2968 -1.2383 -0.9940 -1.2139 Mín. -0.9001 -1.4966 -2.2510 -0.3458 -0.1850
Dif. 1.9976 2.2438 1.8455 1.6840 1.9648 Dif. 2.0201 2.8608 3.2403 1.0931 0.5093
0.700 1.700 Máx. 1.5194 0.7433 0.5943 0.5614 0.5625 1.450 1.200 Máx. 1.1075 1.4686 0.9932 0.7932 0.2707
Mín. -0.9340 -1.2090 -1.6661 -0.7616 -1.4649 Mín. -0.9035 -1.4531 -1.8781 -0.3296 -0.2236
Dif. 2.4534 1.9523 2.2604 1.3230 2.0274 Dif. 2.0111 2.9218 2.8713 1.1228 0.4943
0.700 1.950 Máx. 2.3967 0.9320 0.5706 0.3345 0.4267 1.450 1.450 Máx. 1.0999 1.4955 0.9893 0.7473 0.2181
Mín. -0.8857 -0.9091 -2.2609 -0.4104 -1.6060 Mín. -0.9001 -1.3326 -2.1451 -0.4004 -0.2621
Dif. 3.2824 1.8411 2.8315 0.7449 2.0327 Dif. 2.0000 2.8282 3.1343 1.1477 0.4801
0.700 2.150 Máx. 2.3967 0.9300 0.5706 0.0324 0.3570 1.450 1.700 Máx. 1.0930 1.3440 0.9780 0.6086 0.1730
Mín. -0.8857 -0.7180 -2.2609 -0.1144 -1.5212 Mín. -0.8834 -1.0062 -2.5950 -0.3688 -0.2916
Dif. 3.2824 1.6480 2.8315 0.1468 1.8781 Dif. 1.9764 2.3502 3.5730 0.9774 0.4646
0.950 0.250 Máx. 1.6805 0.5361 0.7543 0.0406 1.1212 1.450 1.950 Máx. 1.0416 0.9956 0.9611 0.3627 0.1732
Mín. -0.6454 -0.9687 -2.7165 -0.1010 -0.2898 Mín. -0.7843 -0.5497 -3.0990 -0.2143 -0.3019
Dif. 2.3259 1.5048 3.4708 0.1416 1.4110 Dif. 1.8259 1.5452 4.0601 0.5769 0.4750
0.950 0.450 Máx. 1.6805 0.7592 0.7543 0.3496 1.1979 1.450 2.150 Máx. 1.0416 0.9979 0.9611 0.0529 0.1652
Mín. -0.6454 -0.9669 -2.7165 -0.2909 -0.3427 Mín. -0.7843 -0.3093 -3.0990 -0.0926 -0.2799
Dif. 2.3259 1.7261 3.4708 0.6405 1.5407 Dif. 1.8259 1.3073 4.0601 0.1455 0.4452
0.950 0.700 Máx. 1.1451 1.1470 0.7760 0.5850 1.1234 1.700 0.250 Máx. 0.9812 0.3407 0.9866 0.0530 0.1804
Mín. -0.6764 -1.0773 -2.1814 -0.5231 -0.4409 Mín. -0.9947 -1.0010 -3.2261 -0.0866 -0.1770
Dif. 1.8216 2.2243 2.9574 1.1082 1.5643 Dif. 1.9759 1.3417 4.2127 0.1396 0.3574
0.950 0.950 Máx. 0.9884 1.3546 0.7891 0.7176 0.9645 1.700 0.450 Máx. 0.9812 0.5850 0.9866 0.3641 0.1872
Mín. -0.6894 -1.2499 -1.7366 -0.6325 -0.5758 Mín. -0.9947 -0.9986 -3.2261 -0.1805 -0.1822
Dif. 1.6778 2.6045 2.5258 1.3501 1.5403 Dif. 1.9759 1.5836 4.2127 0.5446 0.3694
0.950 1.200 Máx. 0.9813 1.3401 0.7935 0.7615 0.7797 1.700 0.700 Máx. 1.0321 1.0445 1.0029 0.6113 0.1483
Mín. -0.6935 -1.3128 -1.3961 -0.6925 -0.7398 Mín. -1.0471 -1.3862 -2.7477 -0.3042 -0.1383
Dif. 1.6749 2.6529 2.1897 1.4540 1.5195 Dif. 2.0792 2.4307 3.7506 0.9155 0.2866
0.950 1.450 Máx. 0.9869 1.2683 0.7891 0.7176 0.6084 1.700 0.950 Máx. 1.0275 1.3651 1.0138 0.7509 0.0810
Mín. -0.6894 -1.3217 -1.6903 -0.6419 -0.9176 Mín. -1.0475 -1.5212 -2.3129 -0.3158 -0.0625
Dif. 1.6762 2.5900 2.4794 1.3595 1.5260 Dif. 2.0750 2.8863 3.3267 1.0667 0.1435
0.950 1.700 Máx. 1.0740 1.0848 0.7760 0.5850 0.4668 1.700 1.200 Máx. 1.0136 1.4724 1.0176 0.7970 0.0459
Mín. -0.6764 -1.1131 -2.1466 -0.5470 -1.0712 Mín. -1.0455 -1.4684 -1.9381 -0.3184 -0.0000
Dif. 1.7504 2.1979 2.9225 1.1320 1.5380 Dif. 2.0591 2.9408 2.9557 1.1155 0.0459
0.950 1.950 Máx. 1.5923 0.9669 0.7543 0.3496 0.3635 1.700 1.450 Máx. 0.9960 1.4980 1.0138 0.7509 0.1259
Mín. -0.6454 -0.7305 -2.6964 -0.3040 -1.1440 Mín. -1.0475 -1.3346 -2.1680 -0.3933 -0.0810
Dif. 2.2377 1.6974 3.4507 0.6535 1.5075 Dif. 2.0435 2.8327 3.1817 1.1442 0.2069
0.950 2.150 Máx. 1.5923 0.9687 0.7543 0.0407 0.3076 1.700 1.700 Máx. 0.9699 1.3429 1.0029 0.6113 0.2069
Mín. -0.6454 -0.5119 -2.6964 -0.1044 -1.0712 Mín. -1.0471 -0.9950 -2.6127 -0.3656 -0.1483
Dif. 2.2377 1.4806 3.4507 0.1451 1.3788 Dif. 2.0170 2.3379 3.6156 0.9769 0.3552
1.200 0.250 Máx. 1.1268 0.4141 0.8840 0.0476 0.7270 1.700 1.950 Máx. 0.8755 0.9986 0.9866 0.3641 0.2541
Mín. -0.4387 -0.9882 -3.0074 -0.0926 -0.2100 Mín. -0.9947 -0.5296 -3.1128 -0.2133 -0.1872
Dif. 1.5655 1.4022 3.8914 0.1402 0.9370 Dif. 1.8702 1.5282 4.0994 0.5774 0.4413
1.200 0.450 Máx. 1.1268 0.6497 0.8840 0.3581 0.7797 1.700 2.150 Máx. 0.8755 1.0010 0.9866 0.0546 0.2444
Mín. -0.4387 -0.9858 -3.0074 -0.2262 -0.2454 Mín. -0.9947 -0.2864 -3.1128 -0.0921 -0.1804
Dif. 1.5655 1.6355 3.8914 0.5843 1.0252 Dif. 1.8702 1.2874 4.0994 0.1467 0.4248
1.200 0.700 Máx. 1.1241 1.0814 0.9029 0.6002 0.7404 1.950 0.250 Máx. 0.7883 0.3753 0.9611 0.0509 0.1151
Mín. -0.6106 -1.2684 -2.5049 -0.3948 -0.3075 Mín. -1.1400 -0.9979 -3.1725 -0.0880 -0.3577
Dif. 1.7347 2.3498 3.4078 0.9949 1.0480 Dif. 1.9283 1.3733 4.1336 0.1389 0.4728
1.200 0.950 Máx. 1.1088 1.3606 0.9152 0.7365 0.6477 1.950 0.450 Máx. 0.7883 0.6171 0.9611 0.3627 0.1358
Mín. -0.6623 -1.4151 -2.0620 -0.4400 -0.3911 Mín. -1.1400 -0.9956 -3.1725 -0.1915 -0.3844
Dif. 1.7712 2.7757 2.9772 1.1765 1.0388 Dif. 1.9283 1.6126 4.1336 0.5541 0.5202
1.200 1.200 Máx. 1.0993 1.4278 0.9194 0.7816 0.5343 1.950 0.700 Máx. 0.8906 1.0661 0.9780 0.6086 0.1762
Mín. -0.6792 -1.4044 -1.6974 -0.4176 -0.4900 Mín. -1.1631 -1.3590 -2.6882 -0.3260 -0.3672
MOD-A4-E_Is.00

Dif. 1.7784 2.8322 2.6168 1.1992 1.0243 Dif. 2.0537 2.4250 3.6662 0.9346 0.5433
1.200 1.450 Máx. 1.0991 1.4273 0.9152 0.7365 0.4251 1.950 0.950 Máx. 0.9052 1.3665 0.9893 0.7473 0.2343
Mín. -0.6623 -1.3277 -1.9890 -0.4793 -0.5929 Mín. -1.1556 -1.4966 -2.2510 -0.3458 -0.3243
Dif. 1.7614 2.7550 2.9041 1.2158 1.0181 Dif. 2.0608 2.8631 3.2403 1.0931 0.5585
1.200 1.700 Máx. 1.1047 1.2690 0.9029 0.6002 0.3329 1.950 1.200 Máx. 0.8966 1.4462 0.9932 0.7932 0.3080
Mín. -0.6106 -1.0431 -2.4447 -0.4259 -0.6771 Mín. -1.1515 -1.4531 -1.8781 -0.3815 -0.2707
Dif. 1.7153 2.3121 3.3477 1.0261 1.0100 Dif. 2.0481 2.8993 2.8713 1.1747 0.5787

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 97 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY Coord. X Coord. Y Cort. X Cort. Y Mom. X Mom. Y Mom. XY
1.950 1.450 Máx. 0.8661 1.4422 0.9893 0.7473 0.3905 2.700 0.700 Máx. 0.9340 1.3283 0.5943 0.5614 0.5099
Mín. -1.1556 -1.3326 -2.0618 -0.4572 -0.2181 Mín. -1.5702 -0.7433 -1.6830 -0.7869 -1.5078
Dif. 2.0216 2.7748 3.0511 1.2046 0.6086 Dif. 2.5043 2.0715 2.2773 1.3483 2.0177
1.950 1.700 Máx. 0.8061 1.2678 0.9780 0.6086 0.4652 2.700 0.950 Máx. 0.9541 1.4346 0.6071 0.6899 0.6882
Mín. -1.1631 -1.0062 -2.5003 -0.4175 -0.1730 Mín. -1.0989 -0.9261 -1.2640 -1.0758 -1.2540
Dif. 1.9692 2.2740 3.4784 1.0261 0.6382 Dif. 2.0530 2.3608 1.8712 1.7657 1.9422
1.950 1.950 Máx. 0.6413 0.9956 0.9611 0.3627 0.5056 2.700 1.200 Máx. 0.9602 1.2671 0.6112 0.7327 0.9188
Mín. -1.1400 -0.5497 -3.0068 -0.2417 -0.1392 Mín. -0.8087 -1.1455 -0.9825 -1.2122 -0.9855
Dif. 1.7813 1.5452 3.9678 0.6044 0.6448 Dif. 1.7690 2.4126 1.5937 1.9449 1.9043
1.950 2.150 Máx. 0.6413 0.9979 0.9611 0.0529 0.4767 2.700 1.450 Máx. 0.9541 0.9366 0.6071 0.6899 1.2041
Mín. -1.1400 -0.3093 -3.0068 -0.0952 -0.1196 Mín. -0.7957 -1.2968 -1.0069 -1.1859 -0.7509
Dif. 1.7813 1.3073 3.9678 0.1481 0.5963 Dif. 1.7498 2.2334 1.6140 1.8758 1.9550
2.200 0.250 Máx. 0.4619 0.4563 0.8840 0.0460 0.2101 2.700 1.700 Máx. 0.9340 0.7433 0.5943 0.5614 1.5225
Mín. -1.1625 -0.9882 -3.0074 -0.0926 -0.7270 Mín. -1.2205 -1.2090 -1.2903 -1.1041 -0.5625
Dif. 1.6245 1.4445 3.8914 0.1386 0.9370 Dif. 2.1545 1.9523 1.8846 1.6654 2.0850
2.200 0.450 Máx. 0.4619 0.6926 0.8840 0.3581 0.2478 2.700 1.950 Máx. 0.8857 0.9320 0.5706 0.3345 1.8016
Mín. -1.1625 -0.9858 -3.0074 -0.2262 -0.7797 Mín. -2.4692 -1.0838 -1.7377 -0.7157 -0.4267
Dif. 1.6245 1.6784 3.8914 0.5843 1.0275 Dif. 3.3548 2.0158 2.3083 1.0501 2.2283
2.200 0.700 Máx. 0.6438 1.1190 0.9029 0.6002 0.3193 2.700 2.150 Máx. 0.8857 0.9300 0.5706 0.0324 1.8041
Mín. -1.1645 -1.2684 -2.5049 -0.3948 -0.7404 Mín. -2.4692 -1.2484 -1.7377 -0.1318 -0.3570
Dif. 1.8083 2.3874 3.4078 0.9949 1.0597 Dif. 3.3548 2.1784 2.3083 0.1643 2.1610
2.200 0.950 Máx. 0.7011 1.3767 0.9152 0.7365 0.4214 2.950 0.250 Máx. 0.9530 1.3716 0.3203 0.0289 0.3401
Mín. -1.1519 -1.4151 -2.0620 -0.4502 -0.6477 Mín. -3.7741 -0.8436 -1.5723 -0.0594 -2.0863
Dif. 1.8530 2.7918 2.9772 1.1867 1.0690 Dif. 4.7271 2.2151 1.8926 0.0883 2.4264
2.200 1.200 Máx. 0.7145 1.3987 0.9194 0.7816 0.5513 2.950 0.450 Máx. 0.9530 1.5121 0.3203 0.3071 0.3983
Mín. -1.1466 -1.4044 -1.6974 -0.5212 -0.5343 Mín. -3.7741 -0.8581 -1.5723 -0.6020 -2.1085
Dif. 1.8611 2.8030 2.6168 1.3028 1.0856 Dif. 4.7271 2.3702 1.8926 0.9091 2.5068
2.200 1.450 Máx. 0.6712 1.3282 0.9152 0.7365 0.7002 2.950 0.700 Máx. 1.0208 1.4118 0.3421 0.5269 0.5366
Mín. -1.1519 -1.3277 -1.8276 -0.6004 -0.4251 Mín. -1.9281 -0.6950 -0.9649 -1.1862 -1.8243
Dif. 1.8232 2.6559 2.7427 1.3369 1.1253 Dif. 2.9489 2.1069 1.3071 1.7132 2.3609
2.200 1.700 Máx. 0.5542 1.1012 0.9029 0.6002 0.8409 2.950 0.950 Máx. 1.0469 1.2683 0.3516 0.6534 0.7339
Mín. -1.1645 -1.0431 -2.2503 -0.5372 -0.3329 Mín. -1.1828 -0.3447 -0.6609 -1.5493 -1.4458
Dif. 1.7186 2.1443 3.1532 1.1374 1.1738 Dif. 2.2298 1.6130 1.0125 2.2027 2.1797
2.200 1.950 Máx. 0.4223 0.9858 0.8840 0.3581 0.9240 2.950 1.200 Máx. 1.0542 0.9331 0.3543 0.6958 0.9889
Mín. -1.3215 -0.6134 -2.7682 -0.3095 -0.2646 Mín. -0.8300 -0.6570 -0.4942 -1.7060 -1.1005
Dif. 1.7438 1.5992 3.6522 0.6676 1.1886 Dif. 1.8842 1.5901 0.8485 2.4018 2.0894
2.200 2.150 Máx. 0.4223 0.9882 0.8840 0.0481 0.8763 2.950 1.450 Máx. 1.0469 0.3999 0.3516 0.6534 1.3119
Mín. -1.3215 -0.3812 -2.7682 -0.1028 -0.2260 Mín. -0.7564 -1.0541 -0.4941 -1.6854 -0.8202
Dif. 1.7438 1.3693 3.6522 0.1509 1.1024 Dif. 1.8033 1.4540 0.8457 2.3388 2.1321
2.450 0.250 Máx. 0.6454 0.5895 0.7543 0.0390 0.2802 2.950 1.700 Máx. 1.0208 0.6950 0.3421 0.5269 1.6986
Mín. -1.6805 -0.9687 -2.7165 -0.1010 -1.1212 Mín. -1.1214 -1.2704 -0.6333 -1.6196 -0.6014
Dif. 2.3259 1.5582 3.4708 0.1401 1.4014 Dif. 2.1421 1.9655 0.9755 2.1466 2.3000
2.450 0.450 Máx. 0.6454 0.8178 0.7543 0.3496 0.3327 2.950 1.950 Máx. 0.9530 0.8581 0.3203 0.3071 2.1204
Mín. -1.6805 -0.9669 -2.7165 -0.2909 -1.1979 Mín. -2.3181 -2.5546 -0.8525 -1.2897 -0.4471
Dif. 2.3259 1.7847 3.4708 0.6405 1.5306 Dif. 3.2711 3.4126 1.1728 1.5968 2.5675
2.450 0.700 Máx. 0.6764 1.2101 0.7760 0.5850 0.4333 2.950 2.150 Máx. 0.9530 0.8436 0.3203 0.0289 2.3274
Mín. -1.1451 -1.0773 -2.1814 -0.5231 -1.1234 Mín. -2.3181 -3.7429 -0.8525 -0.0678 -0.3821
Dif. 1.8216 2.2874 2.9574 1.1082 1.5567 Dif. 3.2711 4.5865 1.1728 0.0966 2.7095
2.450 0.950 Máx. 0.6894 1.4051 0.7891 0.7176 0.5767 3.150 0.450 Máx. 0.8946 1.5121 0.0278 0.3071 0.3758
Mín. -1.0329 -1.2499 -1.7366 -0.7156 -0.9645 Mín. -4.6524 -0.8581 -0.0648 -0.6020 -2.3242
Dif. 1.7222 2.6550 2.5258 1.4332 1.5413 Dif. 5.5470 2.3702 0.0926 0.9091 2.7000
2.450 1.200 Máx. 0.6935 1.3422 0.7935 0.7615 0.7613 3.150 0.700 Máx. 0.9722 1.4118 0.0306 0.5269 0.4944
Mín. -1.0265 -1.3128 -1.3961 -0.8120 -0.7797 Mín. -2.0739 -0.6950 -0.1193 -1.1862 -1.8319
Dif. 1.7200 2.6551 2.1897 1.5734 1.5411 Dif. 3.0460 2.1069 0.1500 1.7132 2.3263
2.450 1.450 Máx. 0.6894 1.1602 0.7891 0.7176 0.9811 3.150 0.950 Máx. 1.0007 1.2683 0.0315 0.6534 0.6814
Mín. -1.0329 -1.3217 -1.4694 -0.8370 -0.6084 Mín. -1.1937 -0.3447 -0.0994 -1.5493 -1.3958
Dif. 1.7222 2.4819 2.2585 1.5546 1.5895 Dif. 2.1944 1.6130 0.1309 2.2027 2.0773
2.450 1.700 Máx. 0.6764 0.8113 0.7760 0.5850 1.2050 3.150 1.200 Máx. 1.0081 0.9331 0.0317 0.6958 0.9232
Mín. -1.1088 -1.1131 -1.8484 -0.7521 -0.4668 Mín. -0.8324 -0.6570 -0.0946 -1.7060 -1.0427
Dif. 1.7852 1.9244 2.6244 1.3371 1.6719 Dif. 1.8405 1.5901 0.1263 2.4018 1.9659
2.450 1.950 Máx. 0.6454 0.9669 0.7543 0.3496 1.3617 3.150 1.450 Máx. 1.0007 0.3999 0.0315 0.6534 1.2312
Mín. -1.9436 -0.7305 -2.3648 -0.4441 -0.3635 Mín. -0.7512 -1.0541 -0.0938 -1.6854 -0.7682
Dif. 2.5890 1.6974 3.1191 0.7937 1.7252 Dif. 1.7519 1.4540 0.1253 2.3388 1.9993
2.450 2.150 Máx. 0.6454 0.9687 0.7543 0.0407 1.3127 3.150 1.700 Máx. 0.9722 0.6950 0.0306 0.5269 1.6124
Mín. -1.9436 -0.5493 -2.3648 -0.1165 -0.3076 Mín. -1.0299 -1.2704 -0.0983 -1.6196 -0.5573
Dif. 2.5890 1.5180 3.1191 0.1571 1.6203 Dif. 2.0020 1.9655 0.1289 2.1466 2.1696
2.700 0.250 Máx. 0.8857 0.7867 0.5706 0.0323 0.3205 3.150 1.950 Máx. 0.8946 0.8581 0.0278 0.3071 2.1048
Mín. -2.4527 -0.9300 -2.2663 -0.1115 -1.5607 Mín. -1.9593 -2.5546 -0.0560 -1.2897 -0.4233
MOD-A4-E_Is.00

Dif. 3.3384 1.7167 2.8369 0.1438 1.8811 Dif. 2.8539 3.4126 0.0839 1.5968 2.5281
2.700 0.450 Máx. 0.8857 0.9962 0.5706 0.3345 0.3841
Mín. -2.4527 -0.9320 -2.2663 -0.3990 -1.6492
Dif. 3.3384 1.9282 2.8369 0.7335 2.0333

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 98 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

13.7.1.2 ESQUEMAS DE ESFUERZOS


E.L.S. Cuasipermanente. Hormigón

CORTANTE X

CORTANTE Y
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 99 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

CORTANTE TOTAL

El Cortante máximo obtenido según las gráficas es de 0,61 kN/m.

MOMENTO X
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 100 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

MOMENTO Y

MOMENTO XY

El Momento máximo obtenido según las gráficas es de 0,48 kNm/m.


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 101 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

13.7.2 DESPLAZAMIENTOS EN NUDOS DE LA LOSA

El asiento máximo obtenido en el cálculo es de 3,32 mm.

13.7.2.1 TABLA DE DESPLAZAMIENTOS

Desp en mm. Giros en radianes x 1000

Cimentación
Coord. X Coord. Y Desp. Z Giro X Giro Y Coord. X Coord. Y Desp. Z Giro X Giro Y
0.250 0.450 Máx. -1.1629 0.6892 0.3037 0.700 0.450 Máx. -1.2469 0.6219 0.2999
Mín. -3.0441 -0.6311 -0.3937 Mín. -2.9953 -0.6204 -0.3729
Dif. 1.8812 1.3203 0.6974 Dif. 1.7484 1.2424 0.6728
0.250 0.700 Máx. -1.1672 0.6715 0.3051 0.700 0.700 Máx. -1.2899 0.6164 0.3006
Mín. -2.9106 -0.6349 -0.3762 Mín. -2.8437 -0.6194 -0.3625
Dif. 1.7434 1.3064 0.6814 Dif. 1.5538 1.2358 0.6631
0.250 0.950 Máx. -1.1712 0.6515 0.3061 0.700 0.950 Máx. -1.2941 0.6085 0.3012
Mín. -2.9048 -0.6420 -0.3660 Mín. -2.7559 -0.6193 -0.3555
Dif. 1.7336 1.2935 0.6720 Dif. 1.4617 1.2278 0.6567
0.250 1.200 Máx. -1.1747 0.6329 0.3066 0.700 1.200 Máx. -1.2978 0.6004 0.3016
Mín. -2.9028 -0.6525 -0.3626 Mín. -2.7553 -0.6209 -0.3531
Dif. 1.7281 1.2854 0.6692 Dif. 1.4575 1.2212 0.6547
0.250 1.450 Máx. -1.1778 0.6225 0.3066 0.700 1.450 Máx. -1.3010 0.5990 0.3018
Mín. -2.9048 -0.6713 -0.3660 Mín. -2.7559 -0.6293 -0.3555
Dif. 1.7270 1.2938 0.6726 Dif. 1.4549 1.2283 0.6573
0.250 1.700 Máx. -1.1804 0.6155 0.3062 0.700 1.700 Máx. -1.3036 0.5992 0.3019
Mín. -2.9106 -0.6915 -0.3762 Mín. -2.8645 -0.6374 -0.3625
Dif. 1.7302 1.3069 0.6825 Dif. 1.5609 1.2366 0.6643
0.250 1.950 Máx. -1.1827 0.6116 0.3053 0.700 1.950 Máx. -1.2516 0.6003 0.3017
Mín. -3.0727 -0.7093 -0.3937 Mín. -3.0214 -0.6431 -0.3729
Dif. 1.8901 1.3210 0.6990 Dif. 1.7699 1.2435 0.6746
0.450 0.250 Máx. -1.1365 0.6513 0.3004 0.700 2.150 Máx. -1.1344 0.6014 0.3013
Mín. -3.1480 -0.6255 -0.4067 Mín. -3.1471 -0.6448 -0.3876
Dif. 2.0115 1.2768 0.7071 Dif. 2.0127 1.2461 0.6889
0.450 0.450 Máx. -1.2172 0.6484 0.3022 0.950 0.250 Máx. -1.1162 0.6028 0.2973
Mín. -3.0209 -0.6253 -0.3863 Mín. -3.0917 -0.6174 -0.3670
Dif. 1.8037 1.2737 0.6885 Dif. 1.9755 1.2202 0.6643
0.450 0.700 Máx. -1.2217 0.6393 0.3033 0.950 0.450 Máx. -1.2364 0.6020 0.2976
Mín. -2.8627 -0.6264 -0.3722 Mín. -2.9744 -0.6158 -0.3566
Dif. 1.6411 1.2657 0.6755 Dif. 1.7381 1.2178 0.6542
0.450 0.950 Máx. -1.2258 0.6270 0.3041 0.950 0.700 Máx. -1.3586 0.5984 0.2979
Mín. -2.8384 -0.6293 -0.3633 Mín. -2.8277 -0.6132 -0.3491
Dif. 1.6126 1.2563 0.6674 Dif. 1.4692 1.2116 0.6470
0.450 1.200 Máx. -1.2294 0.6146 0.3046 0.950 0.950 Máx. -1.3628 0.5934 0.2982
Mín. -2.8371 -0.6347 -0.3603 Mín. -2.6810 -0.6108 -0.3440
Dif. 1.6077 1.2493 0.6649 Dif. 1.3182 1.2042 0.6422
0.450 1.450 Máx. -1.2325 0.6094 0.3047 0.950 1.200 Máx. -1.3666 0.5883 0.2985
Mín. -2.8384 -0.6473 -0.3633 Mín. -2.6746 -0.6094 -0.3422
Dif. 1.6059 1.2567 0.6680 Dif. 1.3080 1.1977 0.6408
0.450 1.700 Máx. -1.2351 0.6065 0.3045 0.950 1.450 Máx. -1.3698 0.5900 0.2989
Mín. -2.8851 -0.6598 -0.3722 Mín. -2.6949 -0.6148 -0.3440
Dif. 1.6500 1.2663 0.6767 Dif. 1.3251 1.2048 0.6429
0.450 1.950 Máx. -1.2373 0.6055 0.3039 0.950 1.700 Máx. -1.3726 0.5927 0.2993
Mín. -3.0484 -0.6690 -0.3863 Mín. -2.8470 -0.6201 -0.3491
Dif. 1.8111 1.2746 0.6902 Dif. 1.4744 1.2128 0.6484
0.450 2.150 Máx. -1.1431 0.6057 0.3027 0.950 1.950 Máx. -1.2432 0.5955 0.2998
Mín. -3.1797 -0.6720 -0.4067 Mín. -2.9992 -0.6239 -0.3566
MOD-A4-E_Is.00

Dif. 2.0366 1.2777 0.7094 Dif. 1.7559 1.2193 0.6564


0.700 0.250 Máx. -1.1257 0.6235 0.2988 0.950 2.150 Máx. -1.1271 0.5971 0.3002
Mín. -3.1167 -0.6214 -0.3876 Mín. -3.1208 -0.6247 -0.3670
Dif. 1.9910 1.2449 0.6863 Dif. 1.9937 1.2219 0.6672

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 102 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Desp. Z Giro X Giro Y Coord. X Coord. Y Desp. Z Giro X Giro Y
1.200 0.250 Máx. -1.1082 0.5885 0.2972 1.700 1.450 Máx. -1.4161 0.5775 0.2983
Mín. -3.0735 -0.6142 -0.3467 Mín. -2.6723 -0.5974 -0.3050
Dif. 1.9653 1.2027 0.6439 Dif. 1.2562 1.1748 0.6033
1.200 0.450 Máx. -1.2277 0.5882 0.2967 1.700 1.700 Máx. -1.3746 0.5832 0.3006
Mín. -2.9591 -0.6121 -0.3395 Mín. -2.8196 -0.6002 -0.3066
Dif. 1.7314 1.2003 0.6362 Dif. 1.4451 1.1834 0.6072
1.200 0.700 Máx. -1.3770 0.5857 0.2963 1.700 1.950 Máx. -1.2315 0.5880 0.3038
Mín. -2.8158 -0.6084 -0.3343 Mín. -2.9665 -0.6024 -0.3089
Dif. 1.4388 1.1942 0.6306 Dif. 1.7350 1.1903 0.6126
1.200 0.950 Máx. -1.4138 0.5824 0.2962 1.700 2.150 Máx. -1.1168 0.5904 0.3080
Mín. -2.6721 -0.6044 -0.3307 Mín. -3.0836 -0.6026 -0.3121
Dif. 1.2583 1.1868 0.6269 Dif. 1.9668 1.1930 0.6201
1.200 1.200 Máx. -1.4143 0.5794 0.2964 1.950 0.250 Máx. -1.0962 0.5801 0.3195
Mín. -2.5954 -0.6010 -0.3295 Mín. -3.0624 -0.6122 -0.3065
Dif. 1.1811 1.1805 0.6259 Dif. 1.9662 1.1923 0.6260
1.200 1.450 Máx. -1.4138 0.5832 0.2970 1.950 0.450 Máx. -1.2152 0.5800 0.3146
Mín. -2.6842 -0.6045 -0.3307 Mín. -2.9497 -0.6100 -0.3047
Dif. 1.2703 1.1877 0.6277 Dif. 1.7344 1.1900 0.6193
1.200 1.700 Máx. -1.3810 0.5876 0.2979 1.950 0.700 Máx. -1.3639 0.5782 0.3110
Mín. -2.8334 -0.6082 -0.3343 Mín. -2.8084 -0.6059 -0.3034
Dif. 1.4524 1.1957 0.6322 Dif. 1.4445 1.1841 0.6145
1.200 1.950 Máx. -1.2368 0.5915 0.2990 1.950 0.950 Máx. -1.4155 0.5758 0.3087
Mín. -2.9823 -0.6109 -0.3395 Mín. -2.6665 -0.6013 -0.3025
Dif. 1.7455 1.2023 0.6386 Dif. 1.2510 1.1771 0.6112
1.200 2.150 Máx. -1.1215 0.5936 0.3005 1.950 1.200 Máx. -1.4160 0.5740 0.3081
Mín. -3.1013 -0.6113 -0.3467 Mín. -2.5238 -0.5974 -0.3022
Dif. 1.9798 1.2049 0.6472 Dif. 1.1078 1.1714 0.6103
1.450 0.250 Máx. -1.1021 0.5801 0.2993 1.950 1.450 Máx. -1.4155 0.5789 0.3094
Mín. -3.0624 -0.6120 -0.3281 Mín. -2.6715 -0.6005 -0.3025
Dif. 1.9603 1.1922 0.6274 Dif. 1.2560 1.1794 0.6119
1.450 0.450 Máx. -1.2211 0.5800 0.2976 1.950 1.700 Máx. -1.3762 0.5843 0.3126
Mín. -2.9497 -0.6098 -0.3232 Mín. -2.8197 -0.6040 -0.3034
Dif. 1.7286 1.1898 0.6209 Dif. 1.4435 1.1883 0.6160
1.450 0.700 Máx. -1.3697 0.5782 0.2965 1.950 1.950 Máx. -1.2328 0.5889 0.3171
Mín. -2.8084 -0.6055 -0.3197 Mín. -2.9675 -0.6066 -0.3047
Dif. 1.4387 1.1837 0.6162 Dif. 1.7347 1.1955 0.6218
1.450 0.950 Máx. -1.4155 0.5758 0.2958 1.950 2.150 Máx. -1.1180 0.5913 0.3234
Mín. -2.6665 -0.6006 -0.3173 Mín. -3.0856 -0.6071 -0.3065
Dif. 1.2510 1.1764 0.6132 Dif. 1.9676 1.1983 0.6299
1.450 1.200 Máx. -1.4160 0.5740 0.2959 2.200 0.250 Máx. -1.0963 0.5885 0.3374
Mín. -2.5282 -0.5962 -0.3165 Mín. -3.0735 -0.6143 -0.3038
Dif. 1.1122 1.1702 0.6124 Dif. 1.9771 1.2028 0.6412
1.450 1.450 Máx. -1.4155 0.5789 0.2967 2.200 0.450 Máx. -1.2158 0.5882 0.3300
Mín. -2.6765 -0.5987 -0.3173 Mín. -2.9591 -0.6124 -0.3031
Dif. 1.2610 1.1776 0.6140 Dif. 1.7432 1.2006 0.6331
1.450 1.700 Máx. -1.3762 0.5843 0.2982 2.200 0.700 Máx. -1.3652 0.5857 0.3246
Mín. -2.8242 -0.6016 -0.3197 Mín. -2.8158 -0.6091 -0.3025
Dif. 1.4480 1.1859 0.6179 Dif. 1.4505 1.1948 0.6272
1.450 1.950 Máx. -1.2328 0.5889 0.3003 2.200 0.950 Máx. -1.4138 0.5824 0.3210
Mín. -2.9714 -0.6038 -0.3232 Mín. -2.6721 -0.6056 -0.3022
Dif. 1.7386 1.1926 0.6235 Dif. 1.2583 1.1881 0.6232
1.450 2.150 Máx. -1.1180 0.5913 0.3030 2.200 1.200 Máx. -1.4143 0.5794 0.3198
Mín. -3.0888 -0.6040 -0.3281 Mín. -2.5924 -0.6032 -0.3020
Dif. 1.9709 1.1953 0.6311 Dif. 1.1781 1.1827 0.6218
1.700 0.250 Máx. -1.0981 0.5774 0.3042 2.200 1.450 Máx. -1.4138 0.5832 0.3214
Mín. -3.0587 -0.6113 -0.3121 Mín. -2.6738 -0.6079 -0.3022
Dif. 1.9605 1.1887 0.6162 Dif. 1.2600 1.1911 0.6235
1.700 0.450 Máx. -1.2170 0.5773 0.3010 2.200 1.700 Máx. -1.3810 0.5876 0.3256
Mín. -2.9465 -0.6090 -0.3089 Mín. -2.8241 -0.6129 -0.3025
Dif. 1.7296 1.1863 0.6099 Dif. 1.4432 1.2005 0.6281
1.700 0.700 Máx. -1.3654 0.5757 0.2988 2.200 1.950 Máx. -1.2368 0.5915 0.3320
Mín. -2.8059 -0.6046 -0.3066 Mín. -2.9744 -0.6166 -0.3031
Dif. 1.4405 1.1803 0.6054 Dif. 1.7376 1.2081 0.6350
1.700 0.950 Máx. -1.4161 0.5736 0.2975 2.200 2.150 Máx. -1.1215 0.5936 0.3409
MOD-A4-E_Is.00

Mín. -2.6646 -0.5995 -0.3050 Mín. -3.0945 -0.6176 -0.3038


Dif. 1.2485 1.1732 0.6025 Dif. 1.9731 1.2111 0.6448
1.700 1.200 Máx. -1.4166 0.5721 0.2973 2.450 0.250 Máx. -1.0983 0.6028 0.3570
Mín. -2.5243 -0.5950 -0.3045 Mín. -3.0917 -0.6175 -0.3035
Dif. 1.1077 1.1671 0.6017 Dif. 1.9934 1.2203 0.6604

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 103 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Coord. X Coord. Y Desp. Z Giro X Giro Y Coord. X Coord. Y Desp. Z Giro X Giro Y
2.450 0.450 Máx. -1.2185 0.6020 0.3463 2.950 0.250 Máx. -1.1063 0.6513 0.3958
Mín. -2.9744 -0.6161 -0.3036 Mín. -3.1480 -0.6250 -0.3060
Dif. 1.7559 1.2181 0.6499 Dif. 2.0417 1.2763 0.7018
2.450 0.700 Máx. -1.3597 0.5984 0.3385 2.950 0.450 Máx. -1.2190 0.6484 0.3750
Mín. -2.8277 -0.6139 -0.3036 Mín. -3.0209 -0.6250 -0.3076
Dif. 1.4680 1.2123 0.6421 Dif. 1.8019 1.2733 0.6825
2.450 0.950 Máx. -1.3606 0.5934 0.3331 2.950 0.700 Máx. -1.2202 0.6393 0.3603
Mín. -2.6810 -0.6123 -0.3037 Mín. -2.8627 -0.6263 -0.3085
Dif. 1.3205 1.2056 0.6368 Dif. 1.6426 1.2656 0.6688
2.450 1.200 Máx. -1.3608 0.5883 0.3311 2.950 0.950 Máx. -1.2209 0.6270 0.3507
Mín. -2.6690 -0.6122 -0.3037 Mín. -2.8230 -0.6299 -0.3091
Dif. 1.3082 1.2005 0.6348 Dif. 1.6020 1.2569 0.6598
2.450 1.450 Máx. -1.3606 0.5900 0.3328 2.950 1.200 Máx. -1.2212 0.6146 0.3467
Mín. -2.6789 -0.6194 -0.3037 Mín. -2.8252 -0.6366 -0.3093
Dif. 1.3183 1.2094 0.6365 Dif. 1.6040 1.2512 0.6560
2.450 1.700 Máx. -1.3597 0.5927 0.3384 2.950 1.450 Máx. -1.2209 0.6094 0.3486
Mín. -2.8324 -0.6269 -0.3036 Mín. -2.8303 -0.6515 -0.3091
Dif. 1.4727 1.2196 0.6420 Dif. 1.6094 1.2609 0.6576
2.450 1.950 Máx. -1.2432 0.5955 0.3470 2.950 1.700 Máx. -1.2202 0.6065 0.3562
Mín. -2.9866 -0.6327 -0.3036 Mín. -2.8573 -0.6678 -0.3085
Dif. 1.7434 1.2281 0.6506 Dif. 1.6371 1.2744 0.6647
2.450 2.150 Máx. -1.1271 0.5971 0.3596 2.950 1.950 Máx. -1.2190 0.6055 0.3695
Mín. -3.1101 -0.6346 -0.3035 Mín. -3.0233 -0.6829 -0.3076
Dif. 1.9830 1.2317 0.6631 Dif. 1.8044 1.2884 0.6771
2.700 0.250 Máx. -1.1017 0.6235 0.3770 2.950 2.150 Máx. -1.1431 0.6057 0.3927
Mín. -3.1167 -0.6213 -0.3046 Mín. -3.1583 -0.6920 -0.3060
Dif. 2.0150 1.2448 0.6816 Dif. 2.0152 1.2977 0.6987
2.700 0.450 Máx. -1.2228 0.6219 0.3620 3.150 0.450 Máx. -1.1636 0.6892 0.3821
Mín. -2.9953 -0.6204 -0.3054 Mín. -3.0441 -0.6302 -0.3090
Dif. 1.7725 1.2424 0.6674 Dif. 1.8805 1.3194 0.6911
2.700 0.700 Máx. -1.2897 0.6164 0.3511 3.150 0.700 Máx. -1.1647 0.6715 0.3641
Mín. -2.8437 -0.6198 -0.3060 Mín. -2.8895 -0.6341 -0.3103
Dif. 1.5540 1.2362 0.6571 Dif. 1.7248 1.3056 0.6744
2.700 0.950 Máx. -1.2905 0.6085 0.3436 3.150 0.950 Máx. -1.1654 0.6515 0.3531
Mín. -2.7436 -0.6206 -0.3063 Mín. -2.8869 -0.6415 -0.3109
Dif. 1.4530 1.2291 0.6499 Dif. 1.7215 1.2930 0.6640
2.700 1.200 Máx. -1.2908 0.6004 0.3405 3.150 1.200 Máx. -1.1656 0.6329 0.3486
Mín. -2.7467 -0.6236 -0.3065 Mín. -2.8882 -0.6528 -0.3112
Dif. 1.4559 1.2240 0.6470 Dif. 1.7226 1.2857 0.6598
2.700 1.450 Máx. -1.2905 0.5990 0.3424 3.150 1.450 Máx. -1.1654 0.6225 0.3504
Mín. -2.7514 -0.6343 -0.3063 Mín. -2.8937 -0.6731 -0.3109
Dif. 1.4608 1.2333 0.6487 Dif. 1.7284 1.2956 0.6614
2.700 1.700 Máx. -1.2897 0.5992 0.3491 3.150 1.700 Máx. -1.1647 0.6155 0.3584
Mín. -2.8438 -0.6456 -0.3060 Mín. -2.9035 -0.6962 -0.3103
Dif. 1.5541 1.2448 0.6551 Dif. 1.7388 1.3116 0.6687
2.700 1.950 Máx. -1.2516 0.6003 0.3603 3.150 1.950 Máx. -1.1636 0.6116 0.3727
Mín. -3.0033 -0.6550 -0.3054 Mín. -3.0406 -0.7199 -0.3090
Dif. 1.7517 1.2553 0.6658 Dif. 1.8770 1.3315 0.6817
2.700 2.150 Máx. -1.1344 0.6014 0.3778
Mín. -3.1317 -0.6591 -0.3046
Dif. 1.9973 1.2605 0.6824
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 104 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

13.7.2.2 ESQUEMA DE DESPLAZAMIENTOS

E.L.S. Hormigón. Desplazamiento en Z

Deformada

El desplazamiento o deformada máxima obtenida según las gráficas es de 3,32 mm.


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 105 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

13.7.3 COMPROBACIÓN E.L.U. VIGAS DE CIMENTACIÓN

COMPROBACIONES DE RESISTENCIA (NCH430.OF2008-DECRETO 60/2011)


Vigas Estado
Disp. Arm. Q N,M Tc Tst Tsl TNMx TVx TVy TVXst TVYst T,Disp.sl T,Disp.st T,Geom.sl T,Arm.st -
'0.200 m' '2.700 m' '1.200 m' CUMPLE
V-001: B30 - B32 Cumple N.P.(1) N.P.(1) N.P.(1) N.P.(2) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(3)
Cumple  = 3.6  = 9.7  = 9.7
'0.200 m' '0.200 m' '1.200 m' CUMPLE
V-002: B33 - B31 Cumple N.P.(1) N.P.(1) N.P.(1) N.P.(2) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(3)
Cumple  = 3.1  = 9.9  = 9.9
'0.825 m' '0.700 m' '0.825 m' CUMPLE
V-003: B33 - B30 Cumple N.P.(1) N.P.(1) N.P.(1) N.P.(2) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(3)
Cumple  = 1.3  = 6.0  = 6.0
'0.700 m' '1.700 m' '0.950 m' CUMPLE
V-004: B31 - B32 Cumple N.P.(1) N.P.(1) N.P.(1) N.P.(2) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(3)
Cumple  = 2.8  = 6.2  = 6.2
Notación:
Disp.: Disposiciones relativas a las armaduras
Arm.: Armadura mínima y máxima
Q: Estado límite de agotamiento frente a cortante (combinaciones no sísmicas)
N,M: Estado límite de agotamiento frente a solicitaciones normales (combinaciones no sísmicas)
Tc: Estado límite de agotamiento por torsión. Compresión oblicua.
Tst: Estado límite de agotamiento por torsión. Tracción en el alma.
Tsl: Estado límite de agotamiento por torsión. Tracción en las armaduras longitudinales.
TNMx: Estado límite de agotamiento por torsión. Interacción entre torsión y esfuerzos normales. Flexión alrededor del eje X.
TVx: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje X. Compresión oblicua
TVy: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje Y. Compresión oblicua
TVXst: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje X. Tracción en el alma.
TVYst: Estado límite de agotamiento por torsión. Interacción entre torsión y cortante en el eje Y. Tracción en el alma.
T,Disp.sl: Estado límite de agotamiento por torsión. Separación entre las barras de la armadura longitudinal.
T,Disp.st: Estado límite de agotamiento por torsión. Separación entre las barras de la armadura transversal.
T,Geom.sl: Estado límite de agotamiento por torsión. Diámetro mínimo de la armadura longitudinal.
T,Arm.st: Estado límite de agotamiento por torsión. Cuantía mínima de estribos cerrados.
-: -
x: Distancia al origen de la barra
: Coeficiente de aprovechamiento (%)
N.P.: No procede
Comprobaciones que no proceden (N.P.):
(1)
La comprobación del estado límite de agotamiento por torsión no procede, ya que no hay momento torsor.
(2)
La comprobación no procede, ya que no hay interacción entre torsión y esfuerzos normales.
(3)
No hay esfuerzos que produzcan tensiones normales para ninguna combinación. Por lo tanto, la comprobación no procede.

COMPROBACIONES DE FISURACIÓN (NCH430.OF2008-DECRETO 60/2011)


Vigas Estado
sC,sup. sC,Lat.Der. sC,inf. sC,Lat.Izq. -
x: 1.45 m
V-001: B30 - B32 N.P.(1) N.P.(1) N.P.(1) N.P.(1) CUMPLE
Cumple
x: 1.45 m
V-002: B33 - B31 N.P.(1) N.P.(1) N.P.(1) N.P.(1) CUMPLE
Cumple
V-003: B33 - B30 N.P.(1) N.P.(1) N.P.(1) N.P.(1) N.P.(1) NO PROCEDE
(1) (1) (1) (1) (1)
V-004: B31 - B32 N.P. N.P. N.P. N.P. N.P. NO PROCEDE
Notación:
sC,sup.: Comprobación de la separación máxima entre barras: Cara superior
sC,Lat.Der.: Comprobación de la separación máxima entre barras: Cara lateral derecha
sC,inf.: Comprobación de la separación máxima entre barras: Cara inferior
sC,Lat.Izq.: Comprobación de la separación máxima entre barras: Cara lateral izquierda
-: -
x: Distancia al origen de la barra
: Coeficiente de aprovechamiento (%)
N.P.: No procede
Comprobaciones que no proceden (N.P.):
(1)
No hay esfuerzos que produzcan tensiones normales para ninguna combinación. Por lo tanto, la comprobación no procede.
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 106 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

13.8 TENSIONES SOBRE EL TERRENO


13.8.1 ESQUEMA DE TENSIONES SOBRE EL TERRENO

La tensión máxima ejercida por la losa en el terreno es de 0,012 MPa.

13.8.2 TENSIONES DEL TERRENO BAJO VIGAS DE CIMENTACIÓN

Tensión admisible en situaciones persistentes: 0.067 MPa


Tensión admisible en situaciones accidentales: 0.089 MPa

Situaciones persistentes o transitorias


Viga Tensión media Tensión en bordes
Estado
Pórtico Tramo Dimensión (MPa) (MPa)
1 V-001: B30-B32 25x20 0.014 0.014 Cumple
2 V-002: B33-B31 25x20 0.013 0.014 Cumple
3 V-003: B33-B30 25x20 0.014 0.014 Cumple
4 V-004: B31-B32 25x20 0.013 0.013 Cumple
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 107 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

14 ESFUERZO HIDROSTÁTICO NAPA FREÁTICA

En el informe geotécnico se detectó napa freática en todas las calicatas ejecutadas, generalmente en
superficie, entre 0,00 a 0,40 metros de profundidad medidos desde nivel de terreno a la fecha de las
prospecciones (19 y 20 de julio de 2022).

Se va a estudiar el empuje generado por la napa freática sobre las distintas cimentaciones y
compararlo con el peso de la cimentación para que no se produzca la supresión de esta.

Centros de Transformación

El sello de fundación se encuentra a una profundidad de 0,35 m. sobre el nivel del terreno, que es el
caso más desfavorable de napa freática, lo que produce un empuje sobre la cimentación del Centro
de Transformación de:

𝐸 𝑑 ⋅𝐴 ⋅𝛾

Donde:
- dW es la diferencia entre la profundidad de la excavación y el nivel de la napa freática,
0,35 m.
- Alosa área de la losa de cimentación, 18,95 m2.
- γagua densidad del agua, 10 kN/m3.

Por lo que el empuje más desfavorable sobre la cimentación de los Centros de Transformación es de:

𝐸 66,325 𝑘𝑁

Para contrarrestar este empuje está el peso de la cimentación compuesta por la losa armada, pilares
enanos, vigas de atado y arqueta in-situ para depósito de aceite.

El peso de dicha cimentación es el volumen de hormigón de esta (11,443 m3), multiplicada por la
densidad del hormigón armado (25 kN/m3), dando un peso total de 286,08 kN.

De estos resultados se deduce que, al ser el peso de la cimentación superior al empuje debido a la
napa freática, no se va a producir la supresión de la cimentación.
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 108 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

Control Room

El sello de fundación se encuentra a una profundidad de 0,10 m. sobre el nivel del terreno, que es el
caso más desfavorable de napa freática, lo que produce un empuje sobre la cimentación del Control
Room de:

𝐸 𝑑 ⋅𝐴 ⋅𝛾

Donde:
- dW es la diferencia entre la profundidad de la excavación y el nivel de la napa freática,
0,10 m.
- Alosa área de la losa de cimentación, 8,16 m2.
- γagua densidad del agua, 10 kN/m3.

Por lo que el empuje más desfavorable sobre la cimentación del control Room es de:

𝐸 8,16 𝑘𝑁

Para contrarrestar este empuje está el peso de la cimentación compuesta por la losa armada.

El peso de dicha cimentación es el volumen de hormigón de esta (1,632 m3), multiplicada por la
densidad del hormigón armado (25 kN/m3), dando un peso total de 40,80 kN.

De estos resultados se deduce que, al ser el peso de la cimentación superior al empuje debido a la
napa freática, no se va a producir la supresión de la cimentación.
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 109 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

15 MANUAL CENTROS DE TRANSFORMACIÓN


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station

User Manual

Issue Draft A
Date 2022-09-07

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2022. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: https://e.huawei.com

Issue Draft A Copyright © Huawei Technologies Co., Ltd. i


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual About This Document

About This Document

Purpose
This document describes the appearance, transportation, storage, human-machine
interaction, and maintenance of the JUPITER-3000K-H1, JUPITER-6000K-H1,
JUPITER-9000K-H1 Smart Transformer Station (also referred to as the STS). Before
installing and operating the STS, read through this document to understand the
safety precautions and get familiar with the functions and features of the STS.
Figures used in this document are for reference only.

Intended Audience
This document is intended for photovoltaic (PV) plant operating personnel and
qualified electricians.

Symbol Conventions
The symbols that may be found in this document are defined as follows.

Symbol Description

Indicates a hazard with a high level of risk


which, if not avoided, will result in death or
serious injury.

Indicates a hazard with a medium level of


risk which, if not avoided, could result in
death or serious injury.

Indicates a hazard with a low level of risk


which, if not avoided, could result in minor
or moderate injury.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. ii


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual About This Document

Symbol Description

Indicates a potentially hazardous situation


which, if not avoided, could result in
equipment damage, data loss, performance
deterioration, or unanticipated results.
NOTICE is used to address practices not
related to personal injury.

Supplements the important information in


the main text.
NOTE is used to address information not
related to personal injury, equipment
damage, and environment deterioration.

Change History
Changes between document issues are cumulative. The latest document issue
contains all the changes made in earlier issues.

Issue 01 (2022-09-07)
This issue is used for first office application (FOA).

Issue Draft A Copyright © Huawei Technologies Co., Ltd. iii


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual Contents

Contents

About This Document................................................................................................................ ii


1 Safety Information.................................................................................................................. 1
1.1 General Safety.......................................................................................................................................................................... 1
1.2 Personnel Requirements....................................................................................................................................................... 4
1.3 Transportation Requirements.............................................................................................................................................. 5
1.4 Storage and Installation Environment Requirements................................................................................................. 5
1.5 Electrical Safety........................................................................................................................................................................ 7
1.6 Mechanical Safety................................................................................................................................................................... 8
1.7 Commissioning...................................................................................................................................................................... 11
1.8 Maintenance and Replacement....................................................................................................................................... 11

2 Products Description.............................................................................................................13
2.1 Overview.................................................................................................................................................................................. 13
2.2 Appearance............................................................................................................................................................................. 14
2.3 Label Description.................................................................................................................................................................. 16
2.4 Components............................................................................................................................................................................ 16
2.4.1 STS.......................................................................................................................................................................................... 17
2.4.2 LV Room................................................................................................................................................................................18
2.4.3 Transformer Room............................................................................................................................................................ 19
2.4.4 MV Room............................................................................................................................................................................. 21
2.4.4.1 DQS-12/24 (CVC)........................................................................................................................................................... 21
2.4.4.2 DQS-12/24 (DVC).......................................................................................................................................................... 22
2.4.4.3 DQS-36 and DQS-40.5 (CVC).................................................................................................................................... 23
2.4.4.4 DQS-40.5 (DVC)............................................................................................................................................................. 24
2.4.4.5 CGM.3 (CVC)................................................................................................................................................................... 25
2.4.4.6 CGM.3 (DVC)................................................................................................................................................................... 26
2.4.4.7 8DJH12/24 (CCV)........................................................................................................................................................... 27
2.4.4.8 8DJH36 (CCV)..................................................................................................................................................................28
2.4.4.9 8DJH12/24 (DCV)...........................................................................................................................................................29
2.4.4.10 8DJH36 (DCV)............................................................................................................................................................... 30
2.4.4.11 8DJH38 (DCV)............................................................................................................................................................... 31
2.5 Configuration Scenario....................................................................................................................................................... 33

3 Electrical Connections.......................................................................................................... 35

Issue Draft A Copyright © Huawei Technologies Co., Ltd. iv


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual Contents

4 Disposing of the STS............................................................................................................. 37


5 Technical Specifications....................................................................................................... 38

Issue Draft A Copyright © Huawei Technologies Co., Ltd. v


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

1 Safety Information

1.1 General Safety


Statement
Before installing, working on, and maintaining the equipment, carefully read this
document and observe all safety instructions provided herein and written on the
equipment itself.
The information provided under the NOTICE, CAUTION, WARNING, and DANGER
headings within this manual is not intended to cover all applicable safety policies,
but instead acts as a supplement to the comprehensive safety information
provided. The Company will not be liable for any consequences that may arise due
to violations of general safety requirements or safety standards concerning the
design, production, and usage of the equipment.
Ensure that the equipment is used in environments that meet its design
specifications. Otherwise, the equipment may become faulty, and any resulting
malfunction, component damage, personal injury, or property damage will not be
covered under the warranty.
Follow local laws and regulations when installing, working on, or maintaining the
equipment. The safety instructions in this document are considered extra
information in addition to local laws and regulations.
The Company will not be liable for any consequences in any of the following
circumstances:
● Installation or use in environments which are not specified in relevant
international, national, or local standards
● Operation beyond the conditions specified in this document
● Unauthorized modifications to the product or software code or removal of the
product
● Failure to follow the operation instructions or safety precautions on the
product or in this document
● Equipment damage due to force majeure, such as earthquakes, fires, storms,
floods, and debris flows

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 1


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

● Damage during transportation by the customer due to failure to comply with


transportation requirements
● Storage conditions that do not meet the requirements specified in this
document

General Requirements

DANGER

Improper operations on high-voltage equipment may cause an electric shock,


which could result in death, serious injury, or serious property damage. Comply
with the following precautions:
● Observe the operation procedures and safety precautions provided in this
manual and other related documents.
● Observe the safety precautions specified in the warning signs and labels on the
equipment.
● Use correct tools properly as required in this manual.
● Observe the safety regulations of the plant, such as the work ticket mechanism.
● Only personnel who need to work on the equipment are allowed to access the
equipment. Install temporary warning signs or fences before working on the
equipment.
● The warning signs and protection labels on the equipment must be clear and
prominent. Do not alter, damage, or block them. Replace the signs and labels
promptly if damaged.
● Do not perform installation, cable connection, maintenance, or replacement
when the equipment is energized.
● Do not use water to clean electrical components in the equipment.
● When the system is running, do not open the cabinet doors or sealing plates in
the energized area.
● Check the equipment for any damage, such as holes, dents, or other signs of
internal damage.
● Check that the preinstalled cables are securely connected.
● Ensure that the components in the equipment are not displaced. Do not alter
the equipment structure or installation procedures without permission.
● Do not power on the equipment before it is installed or confirmed by
professionals.
● Before touching a conductor surface or terminal, measure the voltage at the
contact point. Ensure that the equipment or components to be repaired are
properly grounded to avoid electric shocks.
● If any liquid is found inside the equipment, immediately press the emergency
stop button and contact the onsite management personnel.
● When you power on the system for the first time or perform operations on the
main loop with power on, wear arc protection clothes.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 2


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

WARNING

● During transportation, turnover, installation, cable connection, and


maintenance, comply with the national and local laws, regulations, and
applicable standards.
● Ensure that the materials and tools prepared by the customer comply with the
national and local laws, regulations, and applicable standards.
● Obtain approval from the national or local electric utility company before
connecting the equipment to the grid.

CAUTION

● Do not install other devices on the top of the equipment without the
permission of the Company.
● Do not perform operations such as arc welding, drilling, or cutting on the
equipment. Such operations may damage the container airtightness, equipment
electromagnetic containment, internal components, and cables. Metal scraps
generated during such operations may enter the equipment, which will cause
short circuits on circuit boards, affect equipment functions, or damage the
equipment.
● Do not touch any area where a burn warning sign is attached to prevent burn
hazard.
● Repaint any scratched surfaces caused during equipment transportation or
installation in a timely manner. Scratched equipment surface should not be
exposed to an outdoor environment for extended periods.
● The keys to the door locks of the medium-voltage room, low-voltage room, and
transformer room must be properly kept. Unauthorized personnel are not
allowed to work on the equipment.
● After installing the equipment, clear away packing materials such as cartons,
foam, plastics, and cable ties from the equipment area.
● When performing operations (such as hoisting) over the top of the equipment,
take measures to protect the equipment against damage. After the operations
are complete, check whether the protective paint is damaged. If yes, repair the
paint in a timely manner.
● If there is a likelihood of personal injury or equipment damage during
operations, immediately stop the operation, report the case to the supervisor,
and take feasible protective measures.
● The equipment has an arc discharge channel for the medium-voltage room.
Install the equipment according to the equipment foundation diagram and
ensure that the gap between the medium-voltage room and the foundation is
filled with materials such as mortar.
● During the operation and maintenance of the equipment, if you need to leave
temporarily, close and lock the cabinet doors.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 3


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

NOTICE

Before opening container doors during the installation, operation, and


maintenance of the equipment, clean up any water, ice, snow, or other foreign
objects on the top of the container to prevent foreign objects from falling into the
container.

NOTE

Do not perform reverse engineering, decompilation, disassembling, disassembly, adaptation,


implantation, or other derivative operations on the equipment software. Do not study the
internal implementation of the equipment, obtain the source code of the equipment
software, steal intellectual property rights, or disclose any of the performance test results of
the equipment software.

1.2 Personnel Requirements


● Only qualified personnel or companies are allowed to work on the equipment.
When working on the equipment, wear personal protective equipment (PPE)
that meet local safety protection requirements.

Figure 1-1 Wearing protective equipment

● During transportation, turnover, installation, cable connection, and


maintenance, comply with the national and local laws, regulations, and
applicable standards.
● Maintenance personnel must be familiar with the structure and working
principles of the entire system, and perform operations according to the
manual.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 4


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

1.3 Transportation Requirements


● Select proper transportation tools according to the dimensions and weight of
the product.
● When stacking containers, determine the maximum number of stacking layers
based on the specifications on the containers. Place the containers neatly to
prevent personal injury or device damage caused by toppling.
● Place the product horizontally during transportation.
● Prevent the product from colliding or scratching.
● Requirements for road transportation: Before transporting, conduct road
survey to identify any obstacles in the transportation route to ensure that the
vehicle can pass through the route safely. Survey information: road condition,
height limit, actual height, width limit, actual width, weight limit, traffic
restrictions, and obstacles.
● Requirements for waterway transportation: The waterway must meet the
requirements of full-load voyage.

1.4 Storage and Installation Environment


Requirements
Storage Requirements
● The container doors are closed tightly.
● The temperature and humidity of the storage environment are proper.
Otherwise, the equipment may be damaged.

Figure 1-2 Storage temperature and humidity

● The storage environment must be clean and dry.


● For extended periods of storage, place silica gel moisture absorbent packs in
the medium-voltage room and low-voltage room based on the site
environment, and check and replace the silica gel moisture absorbent packs
on a regular basis.
● After extended periods of storage, test the equipment in accordance with
local laws and regulations and applicable standards before use.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 5


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

Installation Environment Requirements


The equipment is installed outdoors. The site selection requirements are as
follows:
● The equipment is heavy. Ensure that the installation surface is solid enough to
bear the weight of the equipment.
● The site is not located in a low-lying land. The horizontal level of the site is
above the highest water level of that area in history.
● The ground is solid without spongy or soft soil, and is not prone to water
accumulation or subsidence.
● The site is located in a well-ventilated area.
● The site is far away from sources of strong variation, loud noises, and strong
electromagnetic interference.
● The site is not above any underground facilities.
● The site must be a class C or higher environment but not a class D or E
environment.
● The site is far away from dust, cooking fume, harmful gases, and corrosive,
flammable, or explosive objects.
● The site is in an open area and at least 10 m away from any obstacles in all
directions.
● The site is at least 50 m away from residential areas.
● The site temperature is within the range of –25°C to +60°C. If the temperature
exceeds 55°C, the equipment must be installed in a shaded area.
● If the equipment is installed in a place with dense vegetation, in addition to
routine weeding, harden the ground under the equipment to prevent weeds
from growing.
NOTE

● Class C environment: Outdoor areas more than 500 m away from the sea. If a site
is near a pollution source, it must be 1500–3000 m away from heavy pollution
sources, such as smelteries, coal mines, and thermal power plants; 1000–2000 m
away from medium pollution sources such as chemicals, rubber, and galvanization;
or 500–1000 m away from light pollution sources, such as packing houses,
tanneries, boiler rooms, slaughterhouses, landfill sites, and sewage treatment
plants.
● Class D environment: Sea environments or outdoor areas within 500 m away from
the sea. If a site is near a pollution source, it is within 1500 m away from heavy
pollution sources such as smelteries, coal mines, and thermal power plants, within
1000 m away from medium pollution sources such as chemical, rubber, and
galvanization industries, or within 500 m away from light pollution sources such as
packing houses, tanneries, boiler rooms, slaughterhouses, landfill sites, and sewage
treatment plants.
● Class E environment: Special environments, such as underground or underwater
environments.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 6


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

1.5 Electrical Safety


Cabling
● Do not perform any improper operations, for example, dropping cables
directly from a vehicle.
● Do not route cables through air intake or exhaust vents of the equipment.
● Bind cables of the same type together. When routing cables of different types,
ensure that they are at least 30 mm away from each other.
● When routing cables, reserve at least 30 mm clearance between the cables
and heat-generating components or areas. This prevents deterioration or
damage to the cable insulation layer.
● Select cables that comply with local laws and regulations.
● The positions where cables are routed through pipes or holes must be
protected to prevent the cables from being cut by sharp edges.
● Ensure that the cables are properly connected and insulated, and meet
specifications.
● After connecting medium-voltage and low-voltage cables, secure them using
cable supports and cable clips. Ensure that the cables in the backfill area are
in close contact with the ground to prevent cable deformation or damage
during backfilling.
● When the temperature is low, violent impact or vibration may damage the
plastic cable sheathing. To ensure safety, comply with the following
requirements:
– Cables can be laid or installed only when the temperature is higher than
0°C. Handle cables with caution, especially at a low temperature.
– Cables stored at subzero temperatures must be stored at room
temperature for at least 24 hours before they are laid out.

Grounding
● Do not damage the ground conductor.
● Do not work on the equipment in the absence of a properly installed ground
conductor.
● For the equipment that needs to be grounded, install the ground cable first
when installing the equipment and remove the ground cable last when
removing the equipment.
● The main grounding body of the equipment must be permanently connected
to the grounding grid. Before working on the equipment, check its electrical
connections to ensure that it is reliably grounded.

Safety Requirements in Maintenance and Repair


1. Before connecting or removing cables, turn off the protection switch of the
corresponding loop.
2. Place a warning sign indicating that the switch must not be turned on at the
position where the switch resides.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 7


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

3. Use an electroscope of a proper voltage level to check whether the equipment


is energized and ensure that the equipment is completely powered off.
4. If charged bodies are found nearby, block or wrap them with insulation plates
or insulation tapes.
5. Before performing maintenance and repair, securely connect the loop to be
repaired to the main ground loop using a ground cable.

NOTICE

● Before connecting a cable, check that the labels on it are correct.


● If the equipment has multiple inputs, disconnect all the inputs before
working on the equipment.

6. After the maintenance or repair is complete, remove the ground cable


between the loop that has been maintained and the main ground loop.

1.6 Mechanical Safety


Hoisting
● Before hoisting, check the hoisting tools. Do not use damaged or unqualified
hoisting tools.
● Before hoisting objects, ensure that hoisting tools are firmly secured onto a
fixed object or wall that meets the load-bearing requirements.
● Do not drag steel ropes or hoisting tools and prevent them from bumping
into the equipment.
● During hoisting, do not stand or walk under the crane or the hoisted objects.
● Install temporary warning signs or fences to isolate the hoisting area.
● Ensure that the angle between two hoisting ropes is no more than 90
degrees.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 8


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

Using Ladders
● Before using a ladder, ensure that it is intact and its load bearing capacity is
adequate. Do not load a ladder with a weight in excess of its duty rating.
● Use wooden or fiberglass ladders when you need to perform live-line working
at heights.
● Platform ladders with protective rails are preferred. The ladder must be
secured at the four feet and held by a person.
● When a step ladder is used, ensure that the pull ropes are secured and the
ladder is held firm by a person.
● If a straight ladder is used, the ladder must be placed in a secure place. The
recommended angle for a ladder against the floor is 75 degrees, as shown in
the following figure. An angle ruler can be used to measure the angle. Ensure
that the wider end of the ladder is at the bottom, or protective measures have
been taken at the bottom to prevent the ladder from sliding. The ladder must
be held by another person during the operation.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 9


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

● When climbing a ladder, take the following precautions to reduce risks and
ensure safety:
– Keep your body steady.
– Do not climb higher than the fourth rung of the ladder from the top.
– Keep your center of gravity between the side rails, and do not overreach
to the sides.

Safety When Drilling Nearby the Equipment


● Drill holes at proper positions to ensure that no short circuit is caused.
● Wear protective equipment such as safety goggles and protective gloves when
drilling holes.
● When drilling holes, protect the equipment from shavings. After drilling, clean
up any shavings.

Moving Heavy Objects


● When moving heavy objects, ensure that the number of operators must meet
the requirements in the following figure and make proper preparations.

● Wear protective gloves and anti-smashing shoes when manually moving the
equipment.
● Do not scratch the equipment surface or damage components or cables when
moving the equipment.
● When transporting the equipment using a forklift truck, ensure that the forks
are properly positioned so that the equipment does not topple. Before moving
the equipment, secure it to the forklift truck using ropes. When moving the
equipment, assign dedicated personnel to take care of it.
● Move the equipment with caution to prevent collision or fall.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 10


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

1.7 Commissioning
After the equipment is powered on for the first time, ensure that the parameters
are set correctly by professional personnel. Incorrect parameter settings may result
in noncompliance with local grid connection requirements and affect the normal
operations of the equipment.

1.8 Maintenance and Replacement

CAUTION

Before removing a component from the cabinet, ensure that other components on
the cabinet are secure.

NOTICE

● After the equipment stops running, wait for at least 10 minutes to ensure that
the voltage is in the safe range. Before maintenance or repair, ensure that the
transfer switch is turned to the ground position, the potential indicator is off,
the grounding switch of cabinet V in the ring main unit is turned on, and the
low-voltage cabinet is grounded.
● During maintenance, turn off the air circuit breaker on the low-voltage side
and the switch on the high-voltage side of the equipment, and place warning
signs indicating that the switches must not be turned on. If the equipment
supports the automatic mode, disable the automatic mode to ensure that the
equipment will not be powered on unexpectedly.

● Do not open container doors in adverse weather conditions such as rain,


snow, lightning, or dust storms.
● When the transformer is running with power on, do not operate the no-load
voltage regulating switch, do not remove the high/low-voltage tubes, and do
not connect cables or copper bars.
● Before a fan is powered off and stops rotating, do not touch spinning fan
blades with any objects, such as your fingers, components, screws, and tools.
● In the case of a fire, immediately leave the building or the equipment area
and activate the fire alarm or call emergency services. Do not enter a building
or equipment area that is on fire.
● Wear high-voltage insulation gloves, a safety helmet, insulation shoes, and
insulation clothes when working on or maintaining the equipment. Stand on
an insulation stool or ladder when commissioning or operating the control
panel of the ring main unit.
● Ensure that the lighting device (when needed) provides adequate lighting to
illuminate the area you are checking.
● Do not power on the equipment before a fault is rectified.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 11


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 1 Safety Information

● Before maintaining the equipment, ensure that the switches on the low-
voltage and high-voltage sides of the equipment are turned off, and the
grounding switch of the circuit breaker cabinet on the medium-voltage side is
turned on.
● If a switch needs to be turned off for maintenance, place a warning sign
indicating that the switch must not be turned on.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 12


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

2 Products Description

2.1 Overview
Functions
An STS converts low-voltage (LV) AC power generated by solar inverters into
medium-voltage (MV) AC power and feeds it into a power grid.
It is a steel-structure container that houses devices include the LV cabinet,
transformer, ring main unit, and auxiliary power supply to provide a highly
integrated power transformation and distribution solution for utility-scale PV
plants in MV grid-connection scenarios.

Networking
The STS applies to grid-connected large PV plants. A typical grid-connected PV
system consists of PV strings, SUN2000 solar inverters, switch boxes, and an STS.

Figure 2-1 PV-only

(A) PV string (B) SUN2000 solar inverter (C) Switch box (optional)

(D) STS (E) Power grid -

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 13


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

2.2 Appearance
Figure 2-2 Appearance

(1) Low-voltage room (LV) (2) Transformer room (TR) (3) MV room (MV)

(4) Installation position for the (5) Installation position for the (6) Double-swing door for the
UPS Smart Array Controller (SACU) MV room

(7) Ring main unit (8) Auxiliary transformer (9) Double-swing screen door
for the TR room

(10) Holes for AC output (11) Single-swing door for the (12) Double-swing door for the
power cables LV room LV room

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 14


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-3 Container dimensions

Figure 2-4 Dimensions of an anchor pad

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 15


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

2.3 Label Description


Symbol Name Meaning

Electric shock warning The equipment operates at


high voltage. Only qualified
and trained electrical
technicians are allowed to
install and operate the
equipment.

Grounding Indicates the position for


connecting the protective
earthing (PE) cable.

Height label The equipment is high. You


may need tools such as an
insulation stool or a step
ladder to facilitate operation.

Box No. label Displays the equipment box


No.

2.4 Components

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 16


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

2.4.1 STS
Figure 2-5 STS components

(1) LV PANEL A (2) Heat exchangers (3) Smoke sensors

(4) LV PANEL B (5) Transformer (6) Ring main unit

(7) Power distribution box (8) Auxiliary transformer -

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 17


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

2.4.2 LV Room
Figure 2-6 LV PANEL front view

(1) Multimeters (2) Miniature circuit breakers (3) Air circuit breakers
(MULTIFUNCTION METER,
optional)

(4) AC input switches - -

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 18


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-7 LV room interior

(1) Measurement and Control Modules (2) AC input switches

2.4.3 Transformer Room


The transformer room converts the LV AC power into the MV AC power. The main
equipment is a transformer configured with gas, oil temperature, pressure, and oil
level protection devices. At the same time, a comprehensive protection device is
configured in the MV room for the transformer.
This document uses one type of transformer as an example. The appearance of
transformers of different models may vary.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 19


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-8 Transformer

No. Name Function Description

1 Gas relay Generates a gas ● When a minor fault occurs on the


accumulation alarm transformer, the oil of the transformer
or an oil flow trip. generates gas. The gas will rise and
enter the gas relay. In this case, the reed
switch contact for gas accumulation will
be closed to send signals. When there is
too much gas, it can be released
through the gas nozzle of the gas relay.
● When there is a strong gas flow in the
transformer, the reed switch contact for
oil flow will be closed and the circuit
breaker of the ring main unit will trip.

2 Oil feed and Refills or drains oil. ● Oil refilling: Refills the transformer oil
drain valve using an uncontaminated metal or non-
rubber hose and oil injection equipment.
(Note: Prevent air from entering.)
● Oil draining: Lead the transformer oil to
a container using an uncontaminated
metal or non-rubber hose.

3 Oil temperature Measures and Displays the top layer of transformer oil in
indicator controls the real time and issues alarms and trip signals
temperature of the through the built-in temperature control
top layer of switch.
transformer oil.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 20


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

No. Name Function Description

4 (Optional) Measures and The transformer winding temperature is


Winding controls the displayed through thermal simulation
thermostat transformer winding technology, and the alarm and trip signals
temperature through are transmitted through the temperature
thermal simulation control switch.
by measuring the top
oil temperature.

5 Off-load tap Regulates the There are five levels. Level 1 indicates the
changer voltage. maximum tapping value, level 3 indicates
the rated tapping value, and level 5
indicates the minimum tapping value.

6 Dehydrating - The insulation oil in the conservator is


breather connected to the atmosphere through a
dehydrating breather with silica gel to
absorb moisture and impurities in the air
and maintain the performance of the
insulation oil.

7 Oil level gauge Indicates the oil level. Indicates the oil level of the transformer oil
cabinet and reports the alarms of high and
low oil levels.

8 Pressure release Releases pressure. If a transformer is faulty, a large amount of


valve gas is generated, and the pressure of the
insulation oil increases sharply. When the
certain threshold is reached, the
transformer oil is discharged and the
internal pressure of the transformer
decreases to a normal value. At the same
time, a signal is sent to trip the circuit
breaker in the ring main unit.

2.4.4 MV Room
For details about the ring main unit, see the ring main unit manual provided by
the manufacturer. See the ring main unit model on the nameplate.

2.4.4.1 DQS-12/24 (CVC)


NOTE

No cable connector is installed in cabinet G1 or G3. The cable connectors in the figure are
for reference only. The actual position and dimensions may vary.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 21


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-9 DQS-12/24 (CVC)

(1) Operation holes of (2) Load switch operation (3) Isolation switch operation
grounding switches holes hole

(4) Cable connectors (5) Cable clips (6) Ground bar

2.4.4.2 DQS-12/24 (DVC)


NOTE

No cable connector is installed in cabinet G1 or G3. The cable connectors in the figure are
for reference only. The actual position and dimensions may vary.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 22


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-10 DQS-12/24 (DVC)

(1) Operation holes of (2) Load switch operation (3) Isolation switch operation
grounding switches holes hole

(4) Cable connectors (5) Cable clips (6) Ground bar

2.4.4.3 DQS-36 and DQS-40.5 (CVC)


NOTE

No cable connector is installed in cabinet G1 or G3. The cable connectors in the figure are
for reference only. The actual position and dimensions may vary.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 23


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-11 DQS-36 and DQS-40.5 (CVC)

(1) Operation holes of (2) Load switch operation (3) Isolation switch operation
grounding switches holes hole

(4) Cable connectors (5) Cable clips (6) Ground bar

2.4.4.4 DQS-40.5 (DVC)


NOTE

No cable connector is installed in cabinet G1 or G3. The cable connectors in the figure are
for reference only. The actual position and dimensions may vary.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 24


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-12 DQS-40.5 (DVC)

(1) Operation holes of (2) Load switch operation (3) Isolation switch operation
grounding switches holes hole

(4) Cable connectors (5) Cable clips (6) Ground bar

2.4.4.5 CGM.3 (CVC)


NOTE

No cable connector is installed in cabinet G1 or G3. The cable connectors in the figure are
for reference only. The actual position and dimensions may vary.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 25


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-13 CGM.3 (CVC)

(1) Load switch operation (2) Grounding switch operation (3) Cable connectors
holes holes

(4) Cable clips (5) Ground bar -

2.4.4.6 CGM.3 (DVC)


NOTE

No cable connector is installed in cabinet G1 or G3. The cable connectors in the figure are
for reference only. The actual position and dimensions may vary.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 26


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-14 CGM.3 (DVC)

(1) Load switch operation (2) Grounding switch operation (3) Cable connectors
holes holes

(4) Cable clips (5) Ground bar -

2.4.4.7 8DJH12/24 (CCV)


NOTE

● The CCV ring main unit includes a circuit breaker cabinet and two load switch cabinets.
● The secondary room of the ring main unit cannot be opened when the power is on.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 27


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-15 8DJH12/24 (CCV)

(1) Manual grounding (2) Manual load disconnection (3) Isolator

(4) Manually switching off the (5) Manually switching on the (6) Relay
circuit breaker circuit breaker

2.4.4.8 8DJH36 (CCV)


NOTE

● The CCV ring main unit includes a circuit breaker cabinet and two load switch cabinets.
● The secondary room of the ring main unit cannot be opened when the power is on.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 28


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-16 8DJH36 (CCV)

(1) Manual load disconnection (2) Manual grounding (3) Disconnector

(4) Manually switch off the (5) Manually switch on the (6) Circuit breaker electrical
circuit breaker circuit breaker control switch

(7) Relay - -

2.4.4.9 8DJH12/24 (DCV)


NOTE

● The DCV ring main unit includes a direct cable entry cabinet, a load switch cabinet, and
a circuit breaker cabinet.
● The secondary room of the ring main unit cannot be opened when the power is on.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 29


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-17 8DJH12/24 (DCV)

(1) Manual grounding (2) Manual load disconnection (3) Disconnector

(4) Manually switch off the (5) Manually switch on the (6) Circuit breaker electrical
circuit breaker circuit breaker control switch

(7) Temperature and humidity (8) Relay -


controller (Optional)

2.4.4.10 8DJH36 (DCV)


NOTE

● The DCV ring main unit includes a direct cable entry cabinet, a load switch cabinet, and
a circuit breaker cabinet.
● The secondary room of the ring main unit cannot be opened when the power is on.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 30


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-18 8DJH36 (DCV)

(1) Manual grounding (2) Manual load disconnection (3) Disconnector

(4) Manually switch off the (5) Manually switch on the (6) Circuit breaker electrical
circuit breaker circuit breaker control switch

(7) Relay - -

2.4.4.11 8DJH38 (DCV)


NOTE

● The DCV ring main unit includes a direct cable entry cabinet, a load switch cabinet, and
a circuit breaker cabinet.
● The secondary room of the ring main unit cannot be opened when the power is on.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 31


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Figure 2-19 8DJH38 (DCV)

(1) Manual load disconnection (2) Manual grounding

(3) Vacuum circuit breaker low-voltage (4) Disconnector


compartment

(5) Cable connectors (inside the cable room) -

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 32


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

2.5 Configuration Scenario


Figure 2-20 Networking in a PV-only scenario (Components in the dotted box are
optional.)

Component Description

PV string A PV string is a set of PV modules connected in


series.

SUN2000 solar Rated capacity of the Model:


inverter JUPITER-3000K-H1: SUN2000-330KTL-H1 (≤ 11)
3300 kVA
SUN2000-330KTL-H2 (≤ 11)

Rated capacity of the Model:


JUPITER-6000K-H1: SUN2000-330KTL-H1 (≤ 22)
6600 kVA
SUN2000-330KTL-H2 (≤ 22)

Rated capacity of the Model:


JUPITER-9000K-H1: SUN2000-330KTL-H1 (≤ 30)
9000 kVA
SUN2000-330KTL-H2 (≤ 30)

Switch box (optional) Model: ACBox-1/1-D-S

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 33


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 2 Products Description

Component Description

STS Model: JUPITER-3000K-H1, JUPITER-6000K-H1,


JUPITER-9000K-H1

SACU Model: SmartACU2000D-D-03

PV plant management system Model: iMaster NetEco


NetEco software version: iMaster NetEco
V600R022C00SPC120 or later

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 34


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 3 Electrical Connections

3 Electrical Connections

NOTICE

● Cables should have sufficient current-carrying capacity and should not be


overloaded.
● Cables with the same functions should have the same specifications and type.

Figure 3-1 Cable connections (configure the components in the dotted box as
required)

(A) Side view of the STS LV (B) Front view of the STS (C) Side view of the STS MV
cabinet room

(D) Solar inverter (E) AC switch box (F) UPS

(G) Smart array controller (H) Support tracking system (I) Power-consuming device
(SACU)

(J) Power grid (K) STS

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 35


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 3 Electrical Connections

Table 3-1 Cables


No. Cable Type Cross-sectional Outer Diameter Source
Area

1 PE cable Single-core outdoor 50–240 mm2 10–32 mm Prepared by


copper cable and M12 the
OT/DT terminals customer

2 AC input Single-core or three- 50–240 mm2 16–72 mm Prepared by


power core outdoor copper/ the
cablea copper-clad customer
aluminum/aluminum
alloy cable and M12
OT/DT terminals

3 UPS cable N/A N/A N/A Delivered


bundle with the
product

4 SACU cable N/A N/A N/A Delivered


bundle with the
product

5 (Optional) Three-core or four- 2.5–16 mm2 10–32 mm Prepared by


Tracking core outdoor copper the
system cable customer
power cable

6 (Optional) Two-core or three- 2.5–10 mm2 6–20 mm Prepared by


Site core outdoor copper the
auxiliary cable customer
power
supply cable

7 Cabinet G1 Single-core or three- 70–300 mm2 Single-core: 30– Prepared by


cable core outdoor copper/ 52 mm the
copper-clad Three-core: 30– customer
aluminum/aluminum 95 mm
8 Cabinet G3 alloy cable and Prepared by
cable separable shielded the
cable connectors customer

Note a: The AC input power cable can connect to a 300 mm2 or 400 mm2 single-core cable. The
restrictions are as follows:
● Outer diameter of a single-core cable ≤ 35 mm
● Dimensions of the wiring terminal: width ≤ 43 mm; length ≤ 136.5 mm; outer diameter of the
crimping tube ≤ 37 mm

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 36


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 4 Disposing of the STS

4 Disposing of the STS

If the STS has reached its service life, dispose of it according to the local disposal
act for waste electrical appliances.

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 37


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 5 Technical Specifications

5 Technical Specifications

NOTE

Some parameters involve two types of cabinets. For details, see the nameplates of the
cabinets.

Input
Technical JUPITER-3000K-H1 JUPITER-6000K-H1 JUPITER-9000K-H1
Specifications

Capacity rate 3300 kVA 6600 kVA 9000 kVA

Rated input 800 V


voltage

Rated ● 10 kV/11 kV/13.2 kV/15 kV/20 kV/22 kV/23 kV/30 kV/33 kV/35 kV: 50 Hz
frequency ● 13.8 kV/33 kV/34.5 kV: 60 Hz

Maximum 2619.7 A 2 x 2619.7 A 2 x 3572.4 A


input current
at rated
voltage

Transformer
Technical JUPITER-3000K-H1 JUPITER-6000K-H1 JUPITER-9000K-H1
Specification
s

Rated output 10 kV/11 kV/13.2 kV/13.8 kV/15 kV/20 kV/22 kV/23 kV/30 kV/33 kV/34.5 kV /35
voltage kV

Tapping ±2 x 2.5%
range

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 38


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 5 Technical Specifications

Technical JUPITER-3000K-H1 JUPITER-6000K-H1 JUPITER-9000K-H1


Specification
s

impedance 7.0% (0 to +15%) ● Crossing impedance: ● Crossing


characteristics 8.0% (0 to +15%) impedance: 11.5%
● Semi-crossing (±15%)
impedance: 14.0% (0 to ● Semi-crossing
+15%) impedance: 19%
● Splitting impedance: (0 to +15%)
23% (±15%) ● Splitting
impedance: 32%
(±15%)

Protection
Technical JUPITER -3000K- JUPITER -6000K-H1 JUPITER-9000K-H1
Specifications H1

IP ratings of the MV IP54


and LV rooms

Surge protection Type I+II

General Specifications
Technical JUPITER -3000K-H1 JUPITER -6000K-H1 JUPITER-9000K-
Specifications H1

Dimensions (H x W x 6058 mm x 2896 mm x 2438 mm


D)

Weight < 15 tons < 22 tons < 27 tons

Operating temperature –25°C to +55°C

Relative humidity 0% RH to 95% RH

Rated operating 1000 m


altitude

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 39


(2022-09-07)
JUPITER-(3000K, 6000K, 9000K)-H1 Smart
Transformer Station
User Manual 5 Technical Specifications

Feature Specifications
Technical JUPITER -3000K-H1 JUPITER -6000K-H1 JUPITER-9000K-H1
Specification
s

Transformer Oil-immersed
type

Transformer ONAN
cooling type

Transformer Mineral oil


oil type

Transformer Dy11 Dy11-y11


winding
connection

MV SF6, 12–40.5 kV, 600/630 A, three feeders (CVC/CCV or DVC/DCV), 20 kA/3s, 50BF
switchgear (Optional), 50G/51G (Optional)

LV Room ACB (2900 A/800 V/3P) ACB (2900 A/800 V/ ACB (4000 A/800 V/3P),
and MCCB (400 A/800 3P), MCCB (400 A/800 MCCB (400 A/800 V/3P, 2
V/3P, 17 PCS) V/3P, 2 x 11 PCS) x 15 PCS)

Auxiliary Part Specifications


transformer ● 5 kVA,Ii0,800 V/230 V
● 50 kVA, Dyn11, 800 V/400 V
● 50 kVA, Dyn11, 800 V/220 V
Supported device specifications
● 5 kVA,Dyn11,800 V/230 V:2 kW
● 50 kVA, Dyn11, 800 V/400 V: L1 ≤ 15 kW, L2 ≤ 15 kW, L3 ≤ 15 kW
● 50 kVA, Dyn11, 800 V/220 V: L1 ≤ 15 kW, L2 ≤ 15 kW, L3 ≤ 15 kW

Issue Draft A Copyright © Huawei Technologies Co., Ltd. 40


(2022-09-07)
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 156 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

16 COMPUTATIONAL ANALYSIS REPORT OF 20ft S CONTAINER


MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Computational analysis report of

20ft S container

Device name:20ft S container

Device code:STS
Entrusting company:Huawei Technologies Co Ltd
Date of analysis:From April 15, 2019 to May 15, 2019
Analysis software:General finite element software ABAQUS 6.14
Basis and criteria:

GR-63-CORE (Telcordia Technologies Generic Requirements)


CIRSOC 103 (SIMULACION NUMERICA DEL ANA.LISIS SISMICO
ESTATICO DE EDMCIOS SEGUN INPRES)

CIRSOC 102 (REGLAMENTO ARGENTINO DE ACCIÓN DEL VIENTO


SOBRE LAS CONSTRUCCIONES)

IEC62271-202 (High-voltage switchgear and controlgear - Part 202:


High-voltage/ low-voltage prefabricated substation)

ETSI300019-2-4 (European Standard -Telecommunications series)

YD 5083-2005

ASME-AG-1-2015

《20ft S container simulation test requirements》and Pro/E 3D model

provided by Huawei Technologies Co Ltd

Serial number of report:C20190515-1030


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Content

1. Purpose and requirements……………………………………..1

2. Analysis object……………………………………………..2~4

3. Loads,loading combination and boundary conditions……..5~6

4. Evaluation criteria of structural stress………………………..7

5. Results………………………………………………………..8~43

6. Performance evaluation…………...………………………...44~45

7. Opinions and conclusions……………………………………….46

Appendix 1………………………………………………………47

Appendix 2………………………………………………………48

Serial number of report:C20190515-1030


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

1. Purpose and requirements


In order to verify the structural integrity of the 20ft S container under the
specified seismic, wind and snow load conditions and the connection performance
between important structural components, the mechanic calculation analysis of the
container is required.
State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji
University, entrusted by Huawei Technologies Co Ltd, conducts a seismic finite
element calculation analysis on the container from April 15, 2019. According to the
3D container model and simulation test requirements provided by Huawei, the
dynamic characteristics and structural response of the container under specified
installation conditions are obtained.
The specific calculation and analysis contents and requirements are as follows:
(1) Establish finite element model according to the container 3D model and
simulation test requirements;
(2) Evaluating the bearing capacity of the main structural components and main
connections under the design earthquake load;
(3) Evaluating the bearing capacity of the main structural components and main
connections under the design wind load;
(4) Evaluating the bearing capacity of the container roof under the design snow
load;
(5) If the main structural components and main connections of the structure do
not meet the requirements of the corresponding specifications under the design
earthquake, wind load and snow load, the proposed modification should be
proposed and verified.

Serial number of report:C20190515-1030 1 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

2. Analysis object
2.1 Geometric features and structural components
According to the container simulation test requirements, the object of
calculation and analysis is the container produced by Huawei Technologies Co Ltd.
The size of the container (length×width×height) is 6050mm×2450mm×2850mm,
as shown in Figure 2.1.

Figure 2.1 3D model diagram

The main frame of this container is composed of column, beam, top plate,
bottom plate, partition wall, top strengthening beam, bottom strengthening beam and
connecting components. Q355GNH weathering resistant steel is used for steel plates
with a thickness of not more than 6mm in the whole container, and Q235B steel is
used for steel plates exceeding 6mm. Steel angle and welded steel sheet utilize Q345
steel. The thickness of the top plate and the wall plate is 1.6 mm, and the bottom plate
and the door plate are 3.0 mm thick steel plates. The top side beam is a 120mm×

Serial number of report:C20190515-1030 2 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

100mm square steel tube with thickness of 4.0 mm; the bottom side beam is a 175mm
×175mm H-shaped section beam with thickness of 10.0mm; the column is a 6.0mm
thick steel plate; top strengthening beam is a 120mm×35mm U-shaped section beam
with thickness of 3.0mm; bottom strengthening beam is a 250mm×160mm U-shaped
section beam with thickness of 10.0mm. The container-to-ground connecting piece is
angle steel, with thickness of 16.0mm. The anchor bolts, connecting bolts of the
transformer to the bottom plate and the connecting bolts of the angle steel to the
bottom side beams are M20, M16 and M16 stainless steel bolts, respectively.
The container is divided into three compartments: low voltage chamber, variable
voltage chamber, and medium voltage chamber. The low voltage chamber is used to
place the low voltage cabinet; the variable voltage is used to place the transformer;
and the medium voltage chamber is used to place the ring network cabinet. The main
frame of the container, the transformer, the low voltage cabinet, and the ring network
cabinet weigh 5.5t, 15t, 1.6t and 0.8t respectively. Including other additional
components, the total weight of container is about 23.17t.

2.2 Mechanical properties of materials


According to ASME specifications, the allowable stress value of
non-pressure-bearing and non-fastening components is Sm=min (2Sy/3, Su/4); the
allowable stress value of fastening components is Sm=min (Re/4, Rm/5). The
mechanical properties of each material at normal temperature are shown in Table 2.1.

Table 2.1 Mechanical properties of container materials at normal temperature


Elastic Poisson's Yield Tensile Allowable
Material Density
modulus ratio strength strength stress
type (kg/m3)
(MPa) ν Sy (MPa) Su (MPa) (MPa)

Q235B 2.05×105 0.30 7800 235 500 125

Q355GNH 2.05×105 0.30 7800 355 640 160

Serial number of report:C20190515-1030 3 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Q345 2.05×105 0.30 7800 345 620 155

Stainless See
2.05×105 0.30 7800 450 700
steel bolt Table 4.2

2.3 Simulation analysis model


The container was modeled using the general finite element software ABAQUS
6.14. The calculation model and the axis definition are shown in Figure 2.2. The
length direction, width direction and height direction are defined as X/Y/Z direction
respectively.
Shell element is used for simulation of container boxes, internal equipment, fixed
angle steel, etc. Simulation of stainless steel bolt utilizes solid element. The constraint
length is simulated according to the real situation.
The container finite element calculation model has 25320 elements and 28439
nodes with total mass of 23.417t. According to the simulation test requirements, the
actual weight of the container is 23.17t, and the error between the model and the
actual product is 1.07%.

Figure 2.2 Calculation model

Serial number of report:C20190515-1030 4 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

3. Loads,loading combination and boundary conditions


This report uses the ASME Code to assess the analyzed container. According to
the simulation test requirements, the container is analyzed for the most unfavorable
conditions under the combination of seismic load, wind load and snow load to verify
the safety performance of the container structure.

3.1 Structural weight (DW)

The total weight of the container main frame, low voltage cabinet, transformer,
ring network cabinet and other small components is about 23.47t, and acceleration of
gravity is equal to 9.81 m/s2.

3.2 Seismic load (SL)

According to the container simulation test requirements, the seismic load should
be checked according to the ZONE 4 standard of GR-63-CORE, and the damping
ratio is 0.05. The reaction spectra is detailed in Table 3.1 and Appendix 1.
Table 3.1 Response spectra required for seismic analysis
Amplitude (g)
Direction Frequency (Hz)
damping ratio 5%
0.3 0.2

0.6 2.0
Horizontal 2.0 5.0

5.0 5.0

15.0 1.6

50.0 1.6

0.3 0.2

0.6 2.0

2.0 5.0
Vertical 5.0 5.0

15.0 1.6

50.0 1.6

3.3 Wind load (Wind)


Serial number of report:C20190515-1030 5 / 48
State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

According to the simulation test requirements and criterions, the wind speed to
be checked is 52.4m/s.

3.4 Snow load (Snow)

According to the bearing capacity of the strengthening beam at the top of the
container, the maximum snow load that the container roof can withstand is estimated.

3.5 Load combination

(1) Combination condition of Seismic load and Wind load (Combination B):
DW+SL+Wind;
(2) Combination condition of Seismic load, Wind load and Snow load
(Combination D):DW+SL+Wind+Snow;
(3) Consider only snow load.
3.6 Boundary conditions
The four main columns of the container are in contact with the ground for
receiving vertical loads, and six angle steels are bolted to fix the anchor bolts. Each
angle steel is fixed to the ground with two M20 stainless steel bolts to withstand the
overturning moment under seismic and/or wind loads.

Serial number of report:C20190515-1030 6 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

4. Evaluation criteria of structural stress


The main structural components of the container are shell parts, which are
evaluated according to TABLE AA-4321 of ASME criterion. Standard specification
for stainless steel bolt refers to NF3324 of ASME criterion, seeing the appendix for
details.

Table 4.1 Stress evaluation criterion and limits for plate and shell support
components (MPa)
Combinat Type of Stress
Q235B Q355GNH Q345
ion stress limit
1 1.0S 125 160 155
B、D
1   2 1.5S 187.5 240 232.5

Note:  1 indicates membrane stress,  2 indicates bending stress.

Table 4.2 Stress evaluation criterion and limits for stainless steel bolt (MPa)
Type of Stress
Combination Allowable stress
stress limit
Tensile
Ftb  Su / 3.33 210.21
stress f f
B、D ( t )2  ( v )2  1
Shear Ftb Fvb
Fvb  0.62Su /5 86.8
stress

Serial number of report:C20190515-1030 7 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

5. Calculation results

5.1 Calculation result of dynamic characteristic

The first 200-order modes of the container structure were calculated using the
general finite element analysis software ABAQUS 6.14, and the frequency is between
12.14Hz and 121.51Hz. The structural natural frequency and total modal participation
quality are shown in Table 5.1 and Table 5.2. The mode diagrams are shown in Figure
5.1~5.7.
Table 5.1 Natural frequency of container structure
Mode
3 4 8 11 13 14 15
number
Frequency
15.491 15.520 17.466 18.381 24.365 25.251 25.354
(Hz)
Participation
1.427 2.571 3.495 1.688 -4.441 0.574 0.965
factor
X- X- Y- Z- Partition
Mode Roof Roof
direction direction direction direction Wall
feature warpage warpage
translation translation translation translation warpage

Table 5.2 Total participation quality of the first 200-order modes of the container

Vibration direction X-direction Y-direction Z-direction Actual quality

participation quality(t) 22.761 21.172 22.215 23.47

Percentage (%) 96.98 90.21 94.65

Serial number of report:C20190515-1030 8 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.1 The fourth order mode diagram of container

Figure 5.2 The fifth order mode diagram of container

Serial number of report:C20190515-1030 9 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.3 The seventh order mode diagram of container

Figure 5.4 The tenth order mode diagram of container

Serial number of report:C20190515-1030 10 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.5 The fourteenth order mode diagram of container

Figure 5.6 The fifteenth order mode diagram of container

Serial number of report:C20190515-1030 11 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.7 The sixteenth order mode diagram of container

5.2 Structural stress calculation results of combination B

The stress cloud diagram of the main components of the container structure is
shown in Figures 5.8-5.41, excluding the snow load. The maximum stress response of
each major component is shown in Table 5.3.
Table 5.3 The maximum stress response of each major component
under combination B (MPa)
Seismic load Static load Combination B
(DW) (SL+Wind) (DW+SL+Wind)
Components
1 1   2 1 1   2 1 1   2

Column 92.46 141.3 8.45 13.28 100.91 154.58

Bottom beam 80.43 123.01 42.89 63.21 123.32 186.22

Top beam 19.08 31.5 6.67 10.88 25.75 42.38


Bottom
strengthening 81.34 129.23 32.68 43.39 114.02 172.62
beam
Top
strengthening 79.67 121.45 32.01 45.49 111.68 166.94
beam

Serial number of report:C20190515-1030 12 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Bottom plate 109.2 169.9 9.65 15.17 118.85 185.07

Roof 30.77 46.52 7.29 10.54 38.06 57.06

Door panel 44.69 72.97 37.75 62.87 82.44 135.84

Partition wall 64.12 93.13 51.31 75.69 115.43 168.82

Angle steel 46.60 71.39 14.66 24.83 61.26 96.22


Welded steel
62.48 98.18 44.11 72.28 106.59 170.46
sheet

The connection force of bolts of the container under combination B is shown in


Table 5.4, and their maximum value of the stress is shown in Table 5.5~5.7.
Table 5.4 Maximum connection force of bolts under combination B (N)

Seismic load(DW) Static load(SL+Wind)


Type
of bolt Tangential Tangential Axial Tangential Tangential Axial
force Fx force Fy force Fz force Fx force Fy force Fz
Anchor bolt 9055.76 8135.74 23769.8 1880.86 1684.30 5086.8
Bolt of
443.92 1412.95 272.3 116.52 203.57 123.35
transformer
Fixing bolt of
845.64 3498.71 686.68 592.23 483.71 282.95
angle steel

Table 5.5 Maximum stress value of anchor bolt under combination B (MPa)
Seismic load Static load Combination B
Node (DW) Node (SL+Wind) (DW+SL+Wind)
number Normal Shear number Normal Shear Normal Shear
stress σ stress τ stress σ stress τ stress σ stress τ
253 80.83 65.11 253 14.54 4.82 95.37 69.93

1689 80.80 65.11 1689 14.23 4.50 95.03 69.61

1599 73.49 64.24 1599 16.20 4.90 89.69 69.14

637 13.32 64.36 637 3.53 7.59 16.85 71.95

Serial number of report:C20190515-1030 13 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Table 5.6 Maximum stress value of transformer’s bolt under combination B (MPa)
Seismic load Static load Combination B
Node (DW) Node (SL+Wind) (DW+SL+Wind)
number Normal Shear number Normal Shear Normal Shear
stress σ stress τ stress σ stress τ stress σ stress τ
36 7.03 2.01 36 1.01 1.29 8.04 3.3

32 5.77 3.43 32 0.45 1.29 6.22 4.72

36 7.03 2.01 36 1.01 1.29 8.04 3.3

31 5.77 1.63 31 0.43 1.29 6.2 2.92

Table 5.7 Maximum stress value of angle steel’s fixing bolt


under combination B (MPa)
Seismic load Static load Combination B
Node (DW) Node (SL+Wind) (DW+SL+Wind)
number Normal Shear number Normal Shear Normal Shear
stress σ stress τ stress σ stress τ stress σ stress τ
36 17.41 9.43 36 2.95 1.79 20.36 11.22

36 17.41 9.43 36 2.95 1.79 20.36 11.22

Serial number of report:C20190515-1030 14 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.8 Overall stress cloud diagram under seismic load

Figure 5.9 Stress cloud diagram of column under seismic load

Serial number of report:C20190515-1030 15 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.10 Stress cloud diagram of bottom beam under seismic load

Figure 5.11 Stress cloud diagram of top beam under seismic load

Serial number of report:C20190515-1030 16 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.12 Stress cloud diagram of bottom side beam under seismic load

Figure 5.13 Stress cloud diagram of top side beam under seismic load

Serial number of report:C20190515-1030 17 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.14 Stress cloud diagram of bottom strengthening beam


under seismic load

Figure 5.15 Stress cloud diagram of top strengthening beam


under seismic load

Serial number of report:C20190515-1030 18 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.16 Stress cloud diagram of bottom plate under seismic load

Figure 5.17 Stress cloud diagram of roof under seismic load

Serial number of report:C20190515-1030 19 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.18 Stress cloud diagram of door panel under seismic load

Figure 5.19 Stress cloud diagram of partition wall under seismic load

Serial number of report:C20190515-1030 20 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.20 Stress cloud diagram of angle steel under seismic load

Figure 5.21 Stress cloud diagram of welded steel sheet under seismic load

Serial number of report:C20190515-1030 21 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.22 Stress cloud diagram of anchor bolts under seismic load

Figure 5.23 Stress cloud diagram of bolt of transformer under seismic load

Serial number of report:C20190515-1030 22 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.24 Stress cloud diagram of fixing bolt of angle steel


under seismic load

Figure 5.25 Overall stress cloud diagram under combination B

Serial number of report:C20190515-1030 23 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.26 Stress cloud diagram of column under combination B

Figure 5.27 Stress cloud diagram of bottom beam under combination B

Serial number of report:C20190515-1030 24 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.28 Stress cloud diagram of top beam under combination B

Figure 5.29 Stress cloud diagram of bottom side beam


under combination B

Serial number of report:C20190515-1030 25 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.30 Stress cloud diagram of top side beam under combination B

Figure 5.31 Stress cloud diagram of bottom strengthening beam


under combination B

Serial number of report:C20190515-1030 26 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.32 Stress cloud diagram of top strengthening beam


under combination B

Figure 5.33 Stress cloud diagram of bottom plate under combination B

Serial number of report:C20190515-1030 27 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.34 Stress cloud diagram of roof under combination B

Figure 5.35 Stress cloud diagram of door panel under combination B

Serial number of report:C20190515-1030 28 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.36 Stress cloud diagram of partition wall under combination B

Figure 5.37 Stress cloud diagram of angle steel under combination B

Serial number of report:C20190515-1030 29 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.38 Stress cloud diagram of welded steel sheet under combination B

Figure 5.39 Stress cloud diagram of anchor bolts under combination B

Serial number of report:C20190515-1030 30 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.40 Stress cloud diagram of bolt of transformer under combination B

Figure 5.41 Stress cloud diagram of fixing bolt of angle steel


under combination B

Serial number of report:C20190515-1030 31 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

5.3 Structural stress calculation result of combination D

Considering the seismic load and wind load, gradually increase the snow load at
the top of the container from zero. When the snow load at the top of the container
reaches 1.5kPa, the top reinforcing beam basically reaches the limit state. The stress
cloud diagram of the main components of the container structure is shown in Figure
5.42-5.58. The maximum stress response of each major component is shown in Table
5.8.
Table 5.8 The maximum stress response of each major component
under combination D (MPa)
Seismic load Static load Combination D
(DW) (SL+Wind+Snow) (DW+SL+Wind+Snow)
Components
1 1   2 1 1   2 1 1   2

Column 92.46 141.3 7.90 12.23 100.36 153.53

Bottom beam 80.43 123.01 44.83 69.12 125.26 192.13

Top beam 19.08 31.5 4.95 7.88 24.03 39.38


Bottom
strengthening 81.34 129.23 32.45 53.39 113.79 182.62
beam
Top
strengthening 79.67 121.45 83.82 135.49 163.49 256.94
beam
Bottom plate 109.2 169.9 9.54 15.17 118.74 185.07

Roof 30.77 46.52 20.67 30.54 51.44 77.06

Door panel 44.69 72.97 36.73 61.87 81.42 134.84

Partition wall 64.12 93.13 51.11 79.69 115.23 172.82

Angle steel 46.60 71.39 15.88 24.83 62.48 96.22


Welded steel
62.48 98.18 47.79 76.28 110.27 174.46
sheet

Serial number of report:C20190515-1030 32 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

The connection force of the three bolts of the container under combination D is
shown in Table 5.9, and their maximum value of the stress is shown in Table
5.10~5.12.
Table 5.9 Maximum connection force of three bolts under combination D (N)

Seismic load (DW) Static load (SL+Wind+Snow)


Type
of bolt Tangential Tangential Axial Tangential Tangential Axial
force Fx force Fy force Fz force Fx force Fy force Fz
Anchor bolt 9055.76 8135.74 23769.8 1852.60 1796.08 4983.18
Bolt of
443.92 1412.95 272.3 121.04 123.15 317.32
transformer
Fixing bolt of
845.64 3498.71 686.68 574.75 317.32 498.18
angle steel

Table 5.10 Maximum stress value of anchor bolt under combination D (MPa)
Seismic load Static load Combination D
(DW) (SL+Wind+Snow) (DW+SL+Wind+Snow)
Node Node
Normal Shear Normal Shear Normal Shear
number number
stress stress stress stress stress stress
σ τ σ τ σ τ
253 80.83 65.11 253 14.30 4.73 95.13 69.84

1689 80.80 65.11 1689 13.94 4.49 94.74 69.60

1599 73.49 64.24 1599 15.87 4.81 89.36 69.05

637 13.32 64.36 637 3.84 8.48 17.16 72.84

Table 5.11 Maximum stress value of transformer’s bolt


under combination D (MPa)
Seismic load Static load Combination D
(DW) (SL+Wind+Snow) (DW+SL+Wind+Snow)
Node Node
Normal Shear Normal Shear Normal Shear
number number
stress stress stress stress stress stress
σ τ σ τ σ τ
36 7.03 2.01 36 1.05 1.29 8.08 3.3

Serial number of report:C20190515-1030 33 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

32 5.77 3.43 32 0.45 1.29 6.22 4.72

36 7.03 2.01 36 1.05 1.29 8.08 3.3

31 5.77 1.63 31 0.43 1.29 6.2 2.92

Table 5.12 Maximum stress value of angle steel’s fixing bolt


under combination D(MPa)
Seismic load Static load Combination D
(DW) (SL+Wind+Snow) (DW+SL+Wind+Snow)
Node Node
Norma Shear Normal Shear Normal
number number Shear stress
l stress stress stress stress stress
τ
σ τ σ τ σ
36 17.41 9.43 36 2.86 1.78 20.27 11.21

36 17.41 9.43 36 2.86 1.78 20.27 11.21

Figure 5.42 Overall stress cloud diagram under combination D

Serial number of report:C20190515-1030 34 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.43 Stress cloud diagram of column under combination D

Figure 5.44 Stress cloud diagram of bottom beam under combination D

Serial number of report:C20190515-1030 35 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.45 Stress cloud diagram of top beam under combination D

Figure 5.46 Stress cloud diagram of bottom side beam under combination D

Serial number of report:C20190515-1030 36 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.47 Stress cloud diagram of top side beam under combination D

Figure 5.48 Stress cloud diagram of bottom strengthening beam


under combination D

Serial number of report:C20190515-1030 37 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.49 Stress cloud diagram of top strengthening beam


under combination D

Figure 5.50 Stress cloud diagram of bottom plate under combination D

Serial number of report:C20190515-1030 38 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.51 Stress cloud diagram of roof under combination D

Figure 5.52 Stress cloud diagram of door panel under combination D

Serial number of report:C20190515-1030 39 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.53 Stress cloud diagram of partition wall under combination D

Figure 5.54 Stress cloud diagram of angle steel under combination D

Serial number of report:C20190515-1030 40 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.55 Stress cloud diagram of welded steel sheet


under combination D

Figure 5.56 Stress cloud diagram of anchor bolts under combination D

Serial number of report:C20190515-1030 41 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

Figure 5.57 Stress cloud diagram of bolt of transformer


under combination D

Figure 5.58 Stress cloud diagram of fixing bolt of angle steel


under combination D

Serial number of report:C20190515-1030 42 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

5.4 Stress calculation results only under snow load


Without the seismic load and wind load, gradually increase the snow load at the
top of the container from zero. When the snow load at the top of the container reaches
4.2kPa, the top strengthening beam basically reaches the limit state. The stress cloud
diagram of the strengthening beam at the top of the container is shown in Figure 5.59.

Figure 5.59 Stress cloud diagram of the top strengthening beam


under snow load only

Serial number of report:C20190515-1030 43 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

6. Performance evaluation

6.1 Performance evaluation of container’s components under combination B

According to calculation results of maximum response under combination B, the


evaluation criteria and limit values given in Table 4.1 are used for evaluation, and the
results are shown in Table 6.1. At the same time, evaluation of the most unfavorable
seismic stress response of container bolts are shown in Table 6.2.
Table 6.1 Evaluation of the most unfavorable stress of main components

Components 1 1   2 Evaluation result

Column 100.91<125 154.58<187.5 pass

Bottom beam 123.32<125 186.22<187.5 pass

Top beam 25.75<160 42.38<240 pass


Bottom
114.02<125 172.62<187.5 pass
strengthening beam
Top
114.02<160 166.94<240 pass
strengthening beam
Bottom plate 118.85<160 185.07<240 pass

Roof 38.06<160 57.06<240 pass

Door panel 82.44<160 135.84<240 pass

Partition wall 115.43<160 168.82<240 pass

Angle steel 61.26<155 96.22<232.5 pass

Welded steel sheet 106.59<155 170.46<232.5 pass

Table 6.2 Evaluation of seismic response stress of container bolts

Stress of combination
Type of bolt Node number ft 2 f
( )  ( v )2  1 Evaluation result
Ftb Fvb

Anchor bolt 253 0.867 pass

Serial number of report:C20190515-1030 44 / 48


State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

1689 0.860 pass

1599 0.829 pass

637 0.706 pass

36 0.0029 pass

32 0.0038 pass
Bolt of transformer
36 0.0029 pass

31 0.0020 pass

Fixing bolt of 36 0.0261 pass


angle steel 36 0.0261 pass

6.2 Performance evaluation of container’s components under combination D

Combination D considers the effects of seismic loads, wind loads and snow
loads on the container simultaneously. As the snow load on the top plate gradually
increases, the maximum stress of the top strengthening beam gradually heightens.
When the snow load value reaches about 1.5kPa, the top strengthening beam reaches
the limit state. At this moment, the calculation results of the maximum response stress
of structural components are evaluated by the criteria and limit values given in Tables
4.1 and 4.2. The results show that under the combined conditions of seismic load,
wind load and snow load, when the snow load value is less than or equal to 1.5kPa, all
structural components of the container meet the requirements of ASME code.

6.3 Performance evaluation of container’s components with snow load only

Under the premise of not considering seismic load and wind load, when the snow
load value is less than or equal to 4.2kPa, all structural components of the container
meet the corresponding requirements of the ASME code.

Serial number of report:C20190515-1030 45 / 48


同济大学土木工程防灾国家重点实验室振动台试验室
State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

附录 1:分析所采用的地震反应谱

附录 2:ASME 规范中的结构部件应力限值

报告编号:C20190515-1030 第 47 页 共 48 页
同济大学土木工程防灾国家重点实验室振动台试验室
State Key Laboratory of Disaster Reduction in Civil Engineering
Tongji University, Shanghai, China

TABLE AA-4321

ASME 第Ⅲ卷第一册 NF 分卷 NF3324


(1)仅有拉应力时:
对铁素体钢:
Ftb  S u / 2
对奥氏体钢:
Ftb  S u / 3.33
(2)仅有剪切应力时:
对铁素体钢:
Fvb  0.62Su /3
对奥氏体钢:
Fvb  0.62Su /5
(3)拉伸与剪切组合应力:
计算求得的相应拉应力和剪应力满足下列方程:
ft 2 f
( )  ( v )2  1
Ftb Fvb

报告编号:C20190515-1030 第 48 页 共 48 页
TCM Identification Code
CIVIL DESIGN CALCULATION REPORTS
MEMORIA DE CÁLCULO - CIMENTACIONES
DE HORMIGÓN C010-YA-CS-004001

AREA/UNIT/SYSTEM (or OTHER


PV LA QUINTA CHILE
as NEEDED)
Sheet 209 / 216 Issue 03
Client Identification Code
PMGD PROJECTS (CHILE)
Sol del Sur 9

17 COMPROBACIÓN PERNOS DE ANCLAJE CENTRO DE TRANSFORMACIÓN


Para la comprobación de los pernos de anclaje del Centro de Transformación a la cimentación, se
utiliza las cargas indicadas por el fabricante en la tabla 5.9 incluido en el apartado 16 de la presente
memoria.

Estas cargas están indicadas para un perno, por lo que para hacer la comprobación se duplicarán las
cargas.
Con estas cargas se ha comprobado en el programa de anclajes Hilti, que los anclajes cumplen y no
se produce la rotura del borde del hormigón.
A continuación, se presentan los resultados de dicho análisis.
MOD-A4-E_Is.00

This document is Tecnimont Chile property, and cannot be used by others for any purpose, without prior written consent
www.hilti.es Profis Anchor 2.7.3
Empresa: Página: 1
Proyectista: Proyecto: PV LA QUINTA
Dirección: Sub Proyecto I Pos. No.: Pernos de Anclaje
Teléfono I Fax: | Fecha: 30/01/2023
E-mail:

Comentarios del proyectista :

1 Insertar datos
Tipo y tamaño de anclaje: HST3 M20 hef2
Set dinámico/para llenar, o cualquier solución adecuada para rellenar un espacio anular
Profundidad efectiva de anclaje: hef = 101 mm, hnom = 116 mm
Material:
Homologación Nº.: ETA-98/0001
Establecidos I Válidos: 28/07/2016 | -
Prueba: método de cálculo ETAG (Nº 001 Anejo C(2010)) + Sismo (EOTA TR 045)
Categoría de comportamiento sísmico: C2
Tipo de ensayo sísmico: 5.3 a1) Capacidad de diseño
Porcentaje de carga sísmica <=20%: no
Desplazamientos DLS requeridos: Carga a tracción dN,req(DLS) = 6,90 mm, Cortante dV,req(DLS) = 5,20 mm
Fijación a distancia: eb = 0 mm (enrasado); t = 16 mm
Placa de anclaje: lx x ly x t = 160 mm x 200 mm x 16 mm; (Espesor de placa recomendado: no calculado
Perfil: sin perfil
Material Base: no fisurado hormigón, C20/25, fc,cube = 25,00 N/mm2; h = 300 mm
Instalación: taladro hecho con martillo, Condición de instalación: seco
Armadura: sin armadura
sin armadura de borde longitudinal

Geometría [mm] & Carga [kN, kNm]

¡La introducción de datos y resultados deben verificarse, asegurando su correspondencia con las condiciones existentes y asegurando su verosimilitud!
PROFIS Anchor (c) 2003-2009, Hilti AG, FL-9494 Schaan. Hilti es una marca registrada de Hilti AG, Schaan
www.hilti.es Profis Anchor 2.7.3
Empresa: Página: 2
Proyectista: Proyecto: PV LA QUINTA
Dirección: Sub Proyecto I Pos. No.: Pernos de Anclaje
Teléfono I Fax: | Fecha: 30/01/2023
E-mail:

1.1 Combinación de cargas


Caso Descripción Fuerzas [kN] / Momentos [kNm] Sísmo Fuego Util. Max. [%]
1 Seismic load (DW) Vx = 18,112; Vy = 16,271; N = -47,540; C2 no 79
Mx = 0,000; My = 0,000; Mz = 0,000

2 Static load Vx = 3,705; Vy = 3,592; N = -9,966; no no 15


(SL+Wind+Snow) Mx = 0,000; My = 0,000; Mz = 0,000

2 Caso de carga/Resultante de cargas y


Caso de carga: Cargas de diseño

Reacciones en el anclaje [kN] 2


Carga a tracción: (+Tracción, -Compresión)
Anclaje Carga a tracción Carga a cortante Cortante en x Cortante en y
1 0,000 12,174 9,056 8,136
2 0,000 12,174 9,056 8,136 x
Compresión
Máxima extensión del hormigón a compresión: 0,05 [‰]
Máxima tensión del hormigón a compresión: 1,49 [N/mm2]
Tracción resultante en (x/y)=(0/0): 0,000 [kN]
Compresión resultante en (x/y)=(0/0): 47,540 [kN] 1

3 Carga a tracción (ETAG, Anejo C, Sección 5.2.2, EOTA TR 045, Sección 5.6)
Carga [kN] Capacidad [kN] Utilización bN [%] Resultado
Fallo por Acero* N/A N/A N/A N/A
Fallo por extracción* N/A N/A N/A N/A
Rotura por cono de hormigón** N/A N/A N/A N/A
Fallo por fisuración (Splitting)** N/A N/A N/A N/A
* anclaje más solicitado **grupo de anclajes (anclajes en tracción)

¡La introducción de datos y resultados deben verificarse, asegurando su correspondencia con las condiciones existentes y asegurando su verosimilitud!
PROFIS Anchor (c) 2003-2009, Hilti AG, FL-9494 Schaan. Hilti es una marca registrada de Hilti AG, Schaan
www.hilti.es Profis Anchor 2.7.3
Empresa: Página: 3
Proyectista: Proyecto: PV LA QUINTA
Dirección: Sub Proyecto I Pos. No.: Pernos de Anclaje
Teléfono I Fax: | Fecha: 30/01/2023
E-mail:

4 Cortante (ETAG, Anejo C, Sección 5.2.3, EOTA TR 045, Sección 5.6)


Carga [kN] Capacidad [kN] Utilización bV [%] Resultado
Fallo por Acero (sin brazo de palanca)* 12,174 45,492 27 OK
Fallo por Acero (con brazo de palanca)* N/A N/A N/A N/A
Fallo por desconchamiento** 24,347 103,675 24 OK
Rotura de borde de hormigón en 18,621 23,602 79 OK
dirección y+**
* anclaje más solicitado **grupo de anclajes (anclajes relevantes)

4.1 Fallo por Acero (sin brazo de palanca)


V0Rk,s,seis [kN] agap aseis VRk,s,seis [kN]
66,900 1,000 0,850 56,865
gM,s,seis VRd,s,seis [kN] VSd,seis [kN] dV,req(DLS) [mm] dV,seis(DLS) [mm] VRd,s,seis,reduced [kN]
1,250 45,492 12,174 5,20 5,20 45,492

4.2 Fallo por desconchamiento


Ac,N [cm2] A0c,N [cm2] ccr,N [mm] scr,N [mm] k-factor
1182,81 918,09 152 303 3,200
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N
0 1,000 0 1,000 0,981 1,000
N0Rk,c [kN] agap aseis V0Rk,cp,seis [kN] VRk,cp,seis [kN]
51,259 1,000 0,750 207,350 155,512
gM,c,p,seis VRd,cp,seis [kN] VSd,seis [kN] dV,req(DLS) [mm] dV,seis(DLS) [mm] VRd,cp,seis,reduced [kN]
1,500 103,675 24,347 5,20 5,20 103,675

4.3 Rotura de borde de hormigón en dirección y+


lf [mm] dnom [mm] k1 a b
101 20,0 2,400 0,065 0,061
c1 [mm] c'1 [mm] Ac,V [cm2] A0c,V [cm2]
950 239 1500,00 2563,28
y s,V y h,V y a,V ec,V [mm] y ec,V y re,V
0,819 1,092 1,117 0 1,000 1,000
V0Rk,c [kN] agap aseis VRk,c,seis [kN]
71,216 1,000 0,850 35,403
gM,c,seis VRd,c,seis [kN] VSd,seis [kN] dV,req(DLS) [mm] dV,seis(DLS) [mm] VRd,c,seis,reduced [kN]
1,500 23,602 18,621 5,20 5,20 23,602

5 Avisos
• Los métodos de diseño de anclajes en PROFIS Anchor requieren placas de anclaje rígidas según las normas vigentes (ETAG 001 / Anexo
C, EOTA TR029, etc.). Esto significa que no se considera la re-distribución de la carga en los anclajes debido a deformaciones elásticas de
la placa de anclaje - se supone que la placa de anclaje es suficientemente rígida para no deformarse cuando se somete a la carga de
diseño. PROFIS Anchor calcula el espesor de placa de anclaje mínimo requerido con MEF (Métodod de Elementos Finitos) para limitar la
tensión de la placa de anclaje en base a los supuestos explicados anteriormente. La prueba de que la suposición de la placa base rígida es
válida no es llevada a cabo por PROFIS Anchor. Los datos de entrada y los resultados deben ser verificados de acuerdo a las condiciones
existentes!
• ¡Compruebe la regulación nacional para seleccionar la categoría de comportamiento sísmico adecuada!
• La verificación de la transferencia de cargas al material base debe ser verificada de acuerdo con ETAG(2010) Anexo C (2010) Sección 7!
El programa considera que el mortero se instala bajo la placa de anclaje sin formar burbujas de aire y antes de la aplicación de las cargas.
• El diseño es válido sólo en los casos en que el espacio libre de la perforación no sea mayor al dado en la tabla 4.1. de la ETAG 001, Anexo
C. Para mayores diámetros, de espacio libre de perforación, ver el capítulo 1.1. de la ETAG 001, Anexo C.
• El diseño por el método ETAG (taladros rellenos) asume que no hay espacio libre entre los anclajes y la placa de anclaje que está presente.
Esto materializarse llenando el espacio con mortero de suficiente resistencia a la compresión (por ejemplo, mediante el uso del HILTI set
Sísmico /para llenar) o por otros medios adecuados
• La lista de accesorios en este informe es sólo para información del usuario. En cualquier caso, las instrucciones para el uso, mostrados en
el producto, deben ser seguidas para asegurar una correcta instalación.

¡La introducción de datos y resultados deben verificarse, asegurando su correspondencia con las condiciones existentes y asegurando su verosimilitud!
PROFIS Anchor (c) 2003-2009, Hilti AG, FL-9494 Schaan. Hilti es una marca registrada de Hilti AG, Schaan
www.hilti.es Profis Anchor 2.7.3
Empresa: Página: 4
Proyectista: Proyecto: PV LA QUINTA
Dirección: Sub Proyecto I Pos. No.: Pernos de Anclaje
Teléfono I Fax: | Fecha: 30/01/2023
E-mail:

¡La fijación cumple los criterios de diseño!

¡La introducción de datos y resultados deben verificarse, asegurando su correspondencia con las condiciones existentes y asegurando su verosimilitud!
PROFIS Anchor (c) 2003-2009, Hilti AG, FL-9494 Schaan. Hilti es una marca registrada de Hilti AG, Schaan
www.hilti.es Profis Anchor 2.7.3
Empresa: Página: 5
Proyectista: Proyecto: PV LA QUINTA
Dirección: Sub Proyecto I Pos. No.: Pernos de Anclaje
Teléfono I Fax: | Fecha: 30/01/2023
E-mail:

6 Datos de instalación
Placa de anclaje, acero: - Tipo y tamaño de anclaje: HST3 M20 hef2
Perfil: sin perfil Par de apriete de instalación: 0,180 kNm
Diámetro de taladro en chapa: df = 22 mm Diámetro de taladro en material base: 20 mm
Espesor de placa (introducir): 16 mm Profundidad de taladro (min/max): 126 mm
Espesor de placa recomendado: no calculado Mínimo espesor del material base: 200 mm
Método de perforación: Martillo perforador
Limpieza: Se requiere limpieza manual del taladro

6.1 Accesorios recomendados

Taladro Limpieza Instalación


• Rotopercusión • Bombín de limpieza • Set Sísmico/para llenar
• Tamaño adecuado de broca • Llave dinamométrica
• Percusión
y

80 80

50

100
2
100

x
100

1
50

80 80

Coordenadas del anclaje mm


Anclaje x y c-x c+x c-y c+y
1 0 -50 358 142 370 1050
2 0 50 358 142 470 950

¡La introducción de datos y resultados deben verificarse, asegurando su correspondencia con las condiciones existentes y asegurando su verosimilitud!
PROFIS Anchor (c) 2003-2009, Hilti AG, FL-9494 Schaan. Hilti es una marca registrada de Hilti AG, Schaan
www.hilti.es Profis Anchor 2.7.3
Empresa: Página: 6
Proyectista: Proyecto: PV LA QUINTA
Dirección: Sub Proyecto I Pos. No.: Pernos de Anclaje
Teléfono I Fax: | Fecha: 30/01/2023
E-mail:

7 Observaciones;comentarios
• Toda la información y todos los datos contenidos en el software sólo se refieren a la utilización de los productos Hilti y están fundados en
principios, fórmulas y normativas de seguridad conformes a las consignas técnicas de Hilti y en instrucciones de operación, montaje,
ensamblaje, etc., que el usuario debe seguir exhaustivamente. Todas las cifras que en ellos constan son medias; por lo tanto, se deben
realizar pruebas específicas de utilización antes de la utilización del producto Hilti aplicable. Los resultados de los cálculos ejecutados
mediante el software reposan básicamente en los datos que usted introduce en el mismo. Por lo tanto, es usted el único responsable de la
inexistencia de errores, de le exhaustividad y la pertinencia de los datos introducidos por usted mismo. Asimismo, es usted el único
responsable de la verificación de los resultados del cálculo y de la validación de los mismos por un experto, en especial en lo referente al
cumplimiento de las normas y permisos aplicables previamente a su utilización, en particular para su aplicación. El software sólo sirve de
ayuda para la interpretación de las normas y permisos sin ninguna garantía con respecto a la ausencia de errores, la exactitud y la
pertinencia de los resultados o su adaptación a una determinada aplicación.
• Debe usted tomar todas las medidas necesarias y razonables para impedir o limitar los daños causados por el software. En especial, debe
usted tomar sus disposiciones para efectuar regularmente una salvaguarda de los programas y de los datos y, de ser aplicable, ejecutar las
actualizaciones regularmente facilitadas por Hilti. Si no utiliza la función AutoUpdate del software, debe usted comprobar que en cada caso
usted utiliza la versión actual y puesta al día del software, ejecutando actualizaciones manuales a través del Sitio Web Hilti. Hilti no será
considerada como responsable por cualquier consecuencia, tal y como la necesidad de recuperar necesidades o programas perdidos o
dañados, que se deriven de un incumplimiento, por su parte, de sus obligaciones.

¡La introducción de datos y resultados deben verificarse, asegurando su correspondencia con las condiciones existentes y asegurando su verosimilitud!
PROFIS Anchor (c) 2003-2009, Hilti AG, FL-9494 Schaan. Hilti es una marca registrada de Hilti AG, Schaan
HST3 (-R) sujeto a:
Tamaño de anclaje M8 M10 M12 M16 M20 M24
Martillo de perforación*

TE2(-A) – TE30(-A) TE40 – TE70

Perforación de diamante*

DD-30W, DD-EC1

Herramienta de ajuste*
Herramienta de ajuste HS-SC -

Perforación broca hueca*

- TE-CD, TE-YD

Set sísmico/Set de relleno**

Set Sismico/Relleno M8-M20 (Carbono y acero inoxidable


-
A4)

*Métodos de instalación incluidos en ETA-98/0001


**Set dinámico necesario para rellenar el espacio entre el anclaje y la placa
No espacio anular, resistencia de cálculo doble (espacio=1)