E/A-Modul 1: LSB-B participant addess 4 Features other settings (parameters) as pre-entered set
values entry in error memory, or noi reaction, the sensor data coult be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-screen), set sensor to
default value.
184554
E/A-Modul 1: LSB-B participant addess 5 Features other settings (parameters) as pre-entered set
values entry in error memory, or noi reaction, the sensor data coult be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-screen), set sensor to
default value.
E/A-Modul 1: LSB-B participant addess 6 Features other settings (parameters) as pre-entered set
values entry in error memory, or noi reaction, the sensor data coult be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-screen), set sensor to
default value.
194083
E/A-Modul 1: Control active rear axle steering retum report steering status right/left implausible
Error report, value is zeroed.
284454
E/A Modul 2: LSB-B participant address 4 Features other settings (parameter) as pre-entered set
values entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-scrren), set sensor to
default value.
284554
E/A Modul 2: LSB-B participant address 5 Features other settings (parameter) as pre-entered set
values entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-scrren), set sensor to
default value.
284654
E/A Modul 2: LSB-B participant address 6 Features other settings (parameter) as pre-entered set
values entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-scrren), set sensor to
default value
384354
E/A Modul 3: LSB-B participant address 3 Features other settings (parameter) as pre-entered set
values entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-scrren), set sensor to
default value
384654
E/A Modul 3: LSB-B participant address 6 Features other settings (parameter) as pre-entered set
values entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-scrren), set sensor to
default value
384254
E/A Modul 3: LSB-B participant address 2 Features other settings (parameter) as pre-entered set
values entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-scrren), set sensor to
default value
383907
E/A Modul 3: Control Operanting unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) error
indication on display
388131
E/A Modul 3: Participant E/A-Modul 4 Data transfer faulty/missing. Max. Cycle time exeeded
parameterised subtitute values for recelver signals will be used
E/A Modul 4: LSB-B Partcipant address 3 Features other settings (parameters) as pre-entered
set value entry in error memory, or no reation, the snsor data could be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-screen), set sensor to
default value
484254
E/A Modul 4: LSB-B Partcipant address 2 Features other settings (parameters) as pre-entered
set value entry in error memory, or no reation, the snsor data could be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-screen), set sensor to
default value
Módulo de E / S 4: LSB-B Dirección del participante 2
Cuenta con otras configuraciones (parámetros)
como entrada de valor establecido previamente
ingresada en la memoria de error, o sin ninguna
relación, los datos del sensor pueden ser
incorrectos, debido a la configuración incorrecta del
parámetro de verificación de configuración del
sensor / real valor a través del sistema de prueba
(pantalla LSB), ajuste el sensor al valor
predeterminado
484654
E/A Modul 4: LSB-B Partcipant address 6 Features other settings (parameters) as pre-entered
set value entry in error memory, or no reation, the snsor data could be incorrect, due to incorrect
sensor config check parameter set/real value through test system (LSB-screen), set sensor to
default value
494085
E/A Modul 4: Control active rear axle steering Erros in computer at opposite side Safety measure
is initiated
494063
E/A Modul 4: Control active rear axle steering Pressure supply emergency supply centering
circuit too low error reporto n display
584254
E/A Modul 5: LSB-B participant adderess 2 Features other settings (parameters) as pre-entered
set values entry in error memory, or no reaction, the sensor data could be incorrect, due to
incorrect sensor config check parameter set/real value through test system (LSB-screen), set
sensor to default value
584354
E/A Modul 5: LSB-B participant adderess 3 Features other settings (parameters) as pre-entered
set values entry in error memory, or no reaction, the sensor data could be incorrect, due to
incorrect sensor config check parameter set/real value through test system (LSB-screen), set
sensor to default value
Módulo 5 de E / S: la dirección 3 del
participante LSB-B presenta otras
configuraciones (parámetros) como entrada
de valores establecidos previamente
ingresados en la memoria de error, o no hay
reacción, los datos del sensor podrían ser
incorrectos, debido a la configuración
incorrecta del sensor. valor a través del
sistema de prueba (pantalla LSB), ajuste el
sensor al valor predeterminado
584454
E/A Modul 5: LSB-B participant adderess 4 Features other settings (parameters) as pre-entered
set values entry in error memory, or no reaction, the sensor data could be incorrect, due to
incorrect sensor config check parameter set/real value through test system (LSB-screen), set
sensor to default value
584554
E/A Modul 5: LSB-B participant adderess 5 Features other settings (parameters) as pre-entered
set values entry in error memory, or no reaction, the sensor data could be incorrect, due to
incorrect sensor config check parameter set/real value through test system (LSB-screen), set
sensor to default value
883512
Engine chassis: Heater flange unit 1 No voltaje on heater element Failure of pre-and afterheart
phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. Relay / engine control unit
883911
Engine chassis: Sensor fuel pr. Signal outside permisible range (Limit 2) no reation
Check médium for fuel pressure injury. Fix posible mechanical problema