Introduction
These installation instructions contain important information on the installation, functioning, maintenance and storage of VETEC
valves. The control valves are supplied according to customer specification, complete with actuator and accessories. The valves
comply with the European Pressure Equipment Directive 97/23/EC.
Intended use
VETEC control valves are sized individually according to the specific operating conditions provided by the customer, such as
process medium, operating pressure and operating temperature.
The limits of application for DVGW valves concerning the process medium, operating pressure, operating temperature and supply
pressure are given on the nameplate.
Make sure the valves are used as intended.
If the valves are to be used under deviating operating conditions, contact VETEC Ventiltechnik GmbH to make sure that the valves
are suitable for the requirements. Failure to check the valves' suitability for deviating conditions can lead to malfunctions and pose a
considerable danger to persons, goods and the environment.
An insufficient cross-section of the supply air line or an insufficient supply pressure impair the valves' control response or proper
functioning. An excessive supply pressure can damage the actuator and accessories.
Shut off, drain and vent the respective pipe section according to the operator's instructions before installing or removing the valves.
Pressure-test the pipeline before installing the valves.
EB 005.007 Revision: 04 / FTH / 10.11.2015
Created by: Peter Konzack VETEC Ventiltechnik GmbH Siemensstraße 12 Approved by: N. Hock
Date: 2005-04-12 67346 Speyer, Germany Phone: +49 6232 64120 Date: 29.05.2012
Company Standard
Installation Instructions for Types 72.3, 73.7, 73.3, 82.7 and 62.7 Valves with Flanges without
EB 005.007
Actuator
Make sure the pipeline is free of any residue (e.g. weld spatter, metal chips, tools etc.). Remove any foreign particles. Make sure
the valves are mounted free of stress and not exposed to excessive vibration.
If the actuators require support in the pipeline, observe the permissible locations. The permissible locations and weights for support
are detailed in the VETEC regulations. Do not use the piping and control equipment as support or to suspend valves during
transport; do not step on the piping and control equipment to prevent damage.
Subject all valves taken from stock to safety, functional and leak tests before use.
Failure to follow the instructions properly can lead to malfunctions and pose a considerable danger to persons, goods and the
environment.
Operation
The control valves, as parts of the plant, are to be operated according to the operator's instructions and regulations. Unstable
control causes increased wear. Contaminated supply air (e.g. with oil, water, dirt) or auxiliary energy and signals not according to
specifications can cause the accessories or the entire control valve to malfunction or fail. Protect the valves against impermissible
internal or external stress during operation.
The operator must make sure that the valves' permissible pressure and temperature limits are not exceeded due to a thermal
expansion of the process medium.
Wear and corrosion may make it necessary to check the wall thickness of the valve bodies at regular intervals. The minimum
required wall thickness is calculated and specified by VETEC.
Marking
The valves have a nameplate. The nameplate is attached to the actuator or, for deliveries without actuator, to the valve's connecting
flange.
Conformity with the European Pressure Equipment Directive 97/23/EC is documented by the CE marking on the nameplates.
Exception: valves according to 97/23/EC, Article 3, Paragraph 3 (good engineering practice).
The valve and actuator types, nominal size, nominal pressure, serial number, order number etc. are specified on the nameplate.
Installation Instructions for Types 72.3, 73.7, 73.3, 82.7 and 62.7 Valves with Flanges without
EB 005.007
Actuator
The nameplate is
attached to the
valve neck.
The serial number is stamped onto the flange for future inquiries and spare part orders.
Installation Instructions for Types 72.3, 73.7, 73.3, 82.7 and 62.7 Valves with Flanges without
EB 005.007
Actuator
Use only the predefined locations to suspend the control valves during transport. Control lines,
accessories as well as other components with fail-safe function must not be used as
suspensions for transport.
The plug may expand During the heating-up period, the heat is distributed rather unevenly across
due to heat exposure. the valve. The components expand differently. As a result, the plug can get
jammed in the seat ring (see drawing).
Installation Instructions for Types 72.3, 73.7, 73.3, 82.7 and 62.7 Valves with Flanges without
EB 005.007
Actuator
As a result, open the valve slightly (angle of approx. 2° to 3°) before start-up
and close it again after start-up when the process medium has distributed the
heat evenly (see drawing).
. 2° bis 3°
The valve can be opened by the specified angle using the actuator or
additionally mounted travel stops on the actuator.
Electrostatic discharge
Electrostatic charging may occur on the valve bodies during operation in the plant, particularly on valves with insulation. As a result, include a
ground connection as a safety measure.
Attention!
The threaded area must
be free of paint.
Ground connection
Safety measure against
electrostatic charging
Do not subject ceramic parts to sudden temperature increases or other thermal shocks. Strictly observe the thermal shock limits.
Installation Instructions for Types 72.3, 73.7, 73.3, 82.7 and 62.7 Valves with Flanges without
EB 005.007
Actuator
Haltering Ha l te ri n g
Make sure the shaft is not exposed to abrupt loads, e.g. when mounting the actuator or accessories.
To ensure tight shut-off towards the atmosphere, cover the area between the armored bushing and the body with a sealing surface on both
sides.
Installation Instructions for Types 72.3, 73.7, 73.3, 82.7 and 62.7 Valves with Flanges without
EB 005.007
Actuator
Make sure the valve is not damaged while flushing the pipeline by mounting residue (weld spatter, weld rods etc.) or tools forgotten in the
pipeline (wrenches, nuts etc.).
For valves with soft-sealed seats, filter inserts, silencers, attenuation plates etc., it is particularly important to remove the valves from the
pipeline while flushing and replace them with suitable fittings.
Flow divider
Installation Instructions for Types 72.3, 73.7, 73.3, 82.7 and 62.7 Valves with Flanges without
EB 005.007
Actuator
Removing actuator, gears, covers, packings, bolts, screw plugs or other pressure-bearing sealing elements
CAUTION! Do not remove the actuator from the valve during CAUTION! Do not loosen or remove any pressure-bearing
operation. components during operation.
!Note!
Observe the General Operating and Safety Instructions
(BN 004.095) for Mounting and Maintenance.
Note! When replacing components, make sure also to replace all packing rings, packing cords, seals
and O-rings with new parts.
Lubricate all threads and friction surfaces with anti-welding lubricating paste, before assembly.
Lubricate all other surfaces with multi-purpose grease, to facilitate the assembly.
Check that all greases and lubricants meet the requirements for pressure, temperature and medium
compatibility.
Zusammenbauzeichnung
Valve Type 72.3 - DN 25 / NPS 1 Valve Type 72.3 - DN 40-400 / NPS 11/2-16
Only TA-Luft
Version
Only TA-Luft
Version
Valve Type 72.4 DN 25 / NPS 1 Valve Type 72.4 DN 40-300 / NPS 11/2-12
Valve Type 73.7 DN 40-400 / NPS 11/2-16 Valve Type 73.3 DN 40-250 / NPS 11/2-10
1.01 Remove the valve from the pipeline. Also remove accessories (positioner, solenoid valves etc.).
Secure the valve so that it does not tip or tilt uncontrollably.
Pressurize the actuator to release the compression on the plug (if applicable). Remove the bolts
for the bracket. Remove the actuator and fastening bracket.
1.03 Remove the packing flange (pos. 641) and pull the
packing bushing (pos. 640) out of the packing chamber.
Then completely pull the packing bushing and its flange
off the shaft.
Remove the studs (pos. 647).
1.04 Position the body such that the trunnion bearing (pos
400) can be removed.
Remove the bolts (pos. 402) from the trunnion
bearing (pos. 400).
Note! For type 73.3/7 do not reuse the extension
bolts!
1.06 Unscrew the bolt (pos. 101) that secures the shaft and
remove the seal (pos 102).
Note! If the bolt will not be removed, the shaft will
be irreparable damaged.
1.07 Push the shaft out of the plug toothing, for example by
using a rod which is guided through the trunnion-
bearing bore.
Note! Do not damage the internal parts (bearing
bushing, inside of the body and plug).
Note! If the shaft will be re-used it is important to
mark the position of the shaft and the plug to each
other, for example by marking the shaft with a scriber
so that the marking won’t be erased when the shaft is
cleaned.
1.09 Pull the shaft (pos. 300) and packing parts out of the
body.
1.12 Position the body such that the seat-trim (pos. 500,
501, 502, 503, 504) can be removed.
Unscrew the seat holder (pos 501) using a special tool
(refer to BN 004.092).
1.13 Remove the seat ring (pos 500) and seal or shim (if
applicable pos 502, 503, 504).
Note! Probably the seat holder has to be replaced
if the sealing surface is damaged. Decide it after
expertise of the sealing surface.
+0,1 Rz <10
+0,2
2.03 Clean the shaft. The shaft must be shiny and free of
score marks or edges in the packing area.
Check the shaft and rework it (if necessary) to ensure
that the specified tolerances, fit and surface finishes are
complied with. Refer to 2.05 for specifications.
Note! Do not remove the marking bore on the shaft.
2.04 Make sure that there are no sharp edges at the end of
the shaft so that the packing rings and o-rings (if
applicable) can be mounted later.
If there are components to replace use only new parts. Don’t mount used packing rings, gaskets and O- rings.
Lubricate all threads and friction surfaces with anti-welding lubricating paste, before assembly.
Lubricate all other surfaces with multi-purpose grease, to facilitate the assembly.
Check that all greases and lubricants meet the requirements for pressure, temperature and medium
compatibility.
3.01 Note! If a new shaft (pos. 300) is used, the press fit
between shaft and plug has to be adjusted before
installing plug and shaft within the valve. Therefore the
toothing of the shaft has to be driven into the toothing
of the plug with a hammer or a pressing device. During
adjusting shaft and plug it is most important to support
the plug as shown in the picture. If the plug is not
supported it will be vitally damaged!
Note! It is important to mark the position of the shaft
and the plug to each other, for example by marking the
shaft with a scriber
Note! It is very important to attend to the correct
position of shaft and plug to each other as shown in the
following descriptions.
Plug Cap
3.04 Insert the new seal (pos. 401) for the trunnion bearing.
Note! For Type 73. The trunnion bearing is
provided with a sealing lens.
3.05 The Plug (pos. 200) should slide easily from shaft (pos.
300).
If it does not, press the shaft out of the plug with a rod
which is guided through the plug bore.
3.06 Insert the plug (pos. 200) into the body using a rotary
motion.
Note! The plug splines must face the bushing (pos.
303).
3.07 Hold the plug (pos. 200) in position so that the trunnion
bearing (pos. 400) can be inserted through the valve
body into the plug bore.
.
Note! The trunnion bearing for type 73 is provided
with a sealing lens.
3.08 Attach the trunnion bearing (pos. 400) to the valve body
with the bolts (402).
3.09 Press the bushing (pos. 303) into the valve body using
the VETEC bushing tool (according to BN004.092).
Note! Do not tilt the bushing!
3.11 Insert the split ring (pos. 306) into the recess of the
shaft using suitable grease to keep ring in place during
installation
3.14
3.16 Install the packing parts into the valve body using the
following sequence (for standard packing):
spacer (pos. 623), lubricating bushing (601), one
packing ring (pos. 620), 3 packing cords (pos. 621) and
then 1 packing ring (pos.620).
3.19 Install the flange nuts (647) and tighten evenly until the
packing is compressed.
For details on the compression of the packing refer to
order related packing drawing.
If packing leak is detected during testing, slowly and
evenly tighten the flange nuts a little more, continue to
tighten flange nuts until no leak is detected.
3.20 Place the body (pos. 100) into a position so that the
seat ring can be mounted.
Note! Do not damage flange surface on opposite
side of the valve.
3.22 Insert the seat ring (pos. 500) into the valve body.
3.23 Make sure that the sealing surfaces between seat and
plug match exactly.
Before the seat can be properly aligned check plug and
seat for any gaps (A / B) as follows
Turn the plug into the seat ring while using the shaft –
3.24 valve position closed. If necessary turn the shaft with a
suitable lever or, depending on the shaft type, use a
wrench.
On the sealing surface you can see the centre.
Otherwise measure the plug to find the center and
mark a dot on very center of the plug using a small
marker.
There is no need to make any correction if you see in
closed position of valve that the center of the plug is
slightly left warded in off-centre position (see fig. 3.24)
If the seat ring does not tip while you press it against
EB019_030 Revision: 03 Page 15 of 18
Operating Standard
If the gap “A” is between 0.1 and 0.3 you can underlay
with up to 2 shim rings (pos. 502/503).
Sometimes the seat ring is still tipping although it is
underlayed with shim rings , then the gap „A“ is more
than 0,4 mm and you can correct it with a gasket (pos.
504).
fig.1
For bodies made of special materials do not use
shim rings but only gaskets.
fig.2
Abb.3
Abb.3
3.26
If the plug moves eccentrically to the right (view ahead
on the plug from the right to the center) there is a gap
between plug and seat ring.
3.27 There must be no gap "B" between the plug and the
sealing surface of the seat ring.
If a gap “B” exists, the sealing surface of the seat ring
must be machined to size on lathe.
3.29 Screw in the seat retainer (501) which holds the seat
ring but don’t tighten it yet so that the seat ring can be
aligned to the plug.
3.30 Now turn the shaft with the plug into the sealing surface
several times so that the seat ring gets positioned
centrically.
3.31 Tighten the seat retainer (501) while pressing the plug
into the seat's sealing surface so that the seat ring
remains centrically to the plug.
For tightening torques refer to BN004.229.
3.32 Secure the valve so that it does not tip or tilt uncontrollably. Pressurize the actuator to establish
the compression on the plug (only if compression cannot be adjusted subsequently). Mount the
actuator and fastening bracket. Tighten the bolts for the actuator bracket. Mount the accessories
(positioner, solenoid valves etc.). Install the valve into the pipeline.
! Final Inspection !
After assembly, leak-test the packing using a suitable test method. Also test the tight shut-off between seat
and plug. Test the proper functioning with all accessories mounted.
Note!
Observe the general operating and safety instructions (BN 004.095) for
mounting and maintenance.
Note! When replacing components, make sure also to replace all packing rings, packing cords, seals
and o-rings with new parts.
Check that all greases and lubricants meet the requirements for pressure, temperature and medium
compatibility.
Lubricate all threads and friction surfaces with anti-welding lubricating paste, before assembly.
Lubricate all other surfaces with multi-purpose grease, to facilitate the assembly.
Assembly Drawing
1.03 Remove the packing flange (641) and pull the packing
bushing (640) out of the packing chamber. Then com-
pletely pull the packing bushing and its flange off the
shaft.
Remove the studs (647).
1.04 Position the valve such that the trunnion bearing (Pos
400) can be removed safely.
Srew off the bolts (402) from the trunnion bearing.
1.05 Pull out the trunnion bearing (400). The thread in the trun-
nion bearing can be used for disassembly in case the
bearing is stuck and cant be pulled out by hand (See rec-
ommended tool from BN 004.092).
1.06 Position the body such that the valve seat (500 / 501 / 502
/ 503) can be removed safely.
1.07 Screw out the seat retainer (501) with VETEC- tool (see
BN 004.092).
1.08 Lift the seat ring (500) out of the valve body and remove
the seal (504 if applicable) or shim (502/503 if applicable).
1.09 Screw out the seat retainer (501) with VETEC- tool (see
BN 004.092).
1.11 Lift the seat ring (500) out of the valve body and remove
the seal (504 if applicable) or shim (502/503 if applicable).
1.13 Push the shaft (300) out of the plug, for example by using
a tool (or rod) which is guided through the trunnion-
bearing bore.
Note! Do not damage the internal parts (bearing bush-
ing, the inside of the body and plug).
1.14 Pull the shaft (300) with the packing parts out of the body.
1.15 Remove the spacer (308) out of the valve body with the
VETEC special tool (see BN 004.092).
1.16 Remove the plug (300) out of the valve body using a rota-
ry motion as shown in fig.1.16.
Note! If necessary the plug must be replaced . This
has to be decided after evaluation of the sealing surface
1.17 Take the guide bushing (303) out of the valve body with
the VETEC special tool (see BN 004.092).
Note! Stellite bushings can be reused if they do not
have signs of wear.
2.03 Shaft with square (Type AT) Clean the shaft (300).
The shaft must be shiny and free of score marks
or edges in the packing area, so that the packing rings
and o-rings (if applicable) can be mounted later.
Note! Do not remove the mark for the mounting posi-
tion - shaft and plug to each other (see step 1.12)
2.05 Check the shaft and rework it (if necessary) to ensure that
the specified tolerances, fit and surface finishes are com-
plied with.
2.07 Clean the other internal parts of the valve: plug (200),
trunnion bearing (400), seat ring (500), seat retainer (501).
Note! Sealing surface on plug, trunnion bearing and
seat ring must not be damaged.
Note! When replacing components, make sure also to replace all packing rings, packing cords, seals
and o-rings with new parts.
Check that all greases and lubricants meet the requirements for pressure, temperature and medium
compatibility.
Lubricate all threads and friction surfaces with anti-welding lubricating paste, before assembly.
Lubricate all other surfaces with multi-purpose grease, to facilitate the assembly.
3.01 If a new shaft (300) is used it must be mated with the plug
(200) assembly. This is done by aligning the shaft splines
with the internal splines of the plug.
Using a pressing device (or soft blow hammer), drive shaft
into plug (see fig.3.01).
3.02
Note! Shafts for R and M-
actuators only.
3.03
Note! All shafts (Type AT) with marking dimples.
3.05 Press the bushing (303) into the valve body using the
VETEC bushing tool (refer to BN004.092).
3.06 Insert the plug into the body using a rotary motion.
3.08 Hold the plug in position so that the trunnion bearing (400)
can be inserted through the valve body into the plug bore.
3.09 Attach the trunnion bearing (400) to the valve body with
the bolts (402).
Do not completely tighten the bolts.
3.10 Install the spacer (308) onto the shaft using suitable
grease to keep washer in place during installation.
3.11
Note! If the previous shaft is re-used, pay attention
to the marking on the shaft which was applied before dis-
mounting the shaft. Install the shaft in exact orientation as
disassembled.
Install the shaft (300) together with the washer (308) into
the valve body and through the splines of the plug.
For correct placing of the shaft in relation with the plug cap
refere to step 3.02 and 3.03.
3.12 Install the lock washer (309) using the retaining screw
(310) and the spring washer (311).
For tightening torques refer to BN 004.229.
3.12 Install the packing parts into the valve body using the fol-
lowing sequence (standard packing):
guide ring (307)(cup of guide ring must face down toward
valve body), spacer (623) lubricating bushing (601), one
packing ring (620), three packing cords (621) and one
packing ring (620)
When installing, use the VETEC packing tool
(BN 004.092) to push the packing ringss into the valve
body.
3.14 Install the flange nuts (647) and tighten evenly until the
packing is compressed. For details on the compression of
the packing refer to order related packing drawing.
3.15 Place the body in to a position that the seat ring can be
mounted.
3.17 Make sure that the sealing surfaces between seat and
A plug match exactly.
Before the seat can be properly aligned check plug and
seat for any gaps (A / B) as follows:
B
3.18 Turn the plug into the seat ring while using the shaft –
valve position closed. If necessary turn the shaft with a
suitable lever or, depending on the shaft type, use a
wrench.
On the sealing surface you can see the centre. Otherwise
measure the plug to find the centre. Mark a dot on very
centre of the plug using a small marker.
There is no need to make any correction if you see in
closed position of valve that the centre of the plug is slight-
ly left warded in off-centre position (see fig. 3.18) If the
seat ring does not tip while you press it against the support
of the body the seat position is correct
3.19 If the seat ring tips while pressing it against the support of
the body there is a need to correct the gap “A” between
seat ring and support surface of the body (fig. 3.19). If the
gap “A” is between 0,1 and 0,3 you can underlay with up to
2 shim rings (502/503).
If the seat ring is still tipping although it is underlayed with
shim rings , then the gap „A“ is more than 0,4 mm and you
can correct it with a gasket (504).
3.20
For bodies made of special materials do not use shim
rings but only gaskets.
3.23 There must be no gap "B" between the plug and the seal-
ing surface of the seat ring.
If a gap “B” exists, the sealing surface of the seat ring must
be machined to size on lathe.
3.25 Srew in the seat retainer (501) which holds the seat ring
but don’t tighten it yet so that the seat ring can be aligned
to the plug.
3.26 Now turn the shaft with the plug into the sealing surface
several times so that the seatring gets positioned centrical-
ly.
3.27 Tighten the seat retainer (501) while pressing the plug into
the seat's sealing surface so that the seat ring remains
centrically to the plug.
For tightening torques refer to BN 004.229.
3.29 Make sure that the sealing surfaces between seat and
plug match exactly.
Before the seat can be properly aligned check plug and
seat for any gaps (A / B) as described in steps 3.18 to 3.24
3.30 Screw in the bolts (507) of the seat ring but don’t tighten
them yet so that the seatring can be aligned to the plug.
Now slide the seat ring against the closing direction. Tight-
en the 4 screws as shown in the figure minimal, so that the
seat ring can be aligned.
Turn the shaft with the plug into the sealing surface so that
the seatring gets positioned centrically.
3.31 Tighten evenly the bolts (507) of the seat ring while press-
ing the plug into the seat's sealing surface so that the seat
ring remains centrically to the plug.
tighten evenly
3.32 Fully tighten the bolts (as shown in the diagram below)
after properly aligned the seat. For tightening torques refer
to BN 004.229.
3.33
Install the seat retainer (501) and tighten it. For tightening
torques refer to BN 004.229.
3.34 Secure the valve so that it does not tip or tilt uncontrollably. Mount the bracket. Pressurize the
actuator (only for fail safe position FC). Mount the actuator and tighten the bolts for the actuator
bracket. Mount the accessories (positioner, solenoid valves etc.). Install the valve into the pipeline.
Final inspection
After assembly, leak-test the packing using a suitable test method. Also test the tight shut-off between seat
and plug. Test the proper functioning with all accessories mounted.
4. Korrektes Heben und Transportieren von Stellventilen / Correct Lifting and Transporting of Control
Valves ........................................................................................................................................................... 3
5. Heben von Ventilen mit montiertem Antrieb Typ AT / Lifting of Valves with mounted Actuator
Type AT ........................................................................................................................................................ 5
6. Heben von Ventilen mit montiertem Antrieb Typ AT und Getriebe (Handrad) / Lifting of Valves with
EB005.050 Revision 0 1 2 3 4 5 6 7 8 9
Ersteller F.Thiede Revisor fth fth
Seite 1 von 7
Genehmigt P. Konzack Genehmigt ko Ko
Datum 17.11.2014 Datum 17.11.14 28.09.16
EINBAU- UND BEDIENUNGSANLEITUNG
EB019.022
MOUNTING AND OPERATING INSTRUCTIONS
Hebeanweisung für Ventile mit montiertem Antrieb
Typ AT/
Lifting Instructions for Valves with mounted Actuator
Type AT
1. Hinweise / Notes
Diese Einbau- und Bedienungsanleitung gilt These installation and operating instructions apply only
ausschließlich für Stellventile mit AT Antrieb. for control valves with AT actuator.
Für Schäden und Betriebsstörungen die durch die For damages and operational breakdowns that are
Nichtbeachtung dieser Anweisung entstehen, caused by noncompliance with these instructions, we
übernehmen wir keine Haftung. assume no liability.
Die verwendeten Symbole haben folgende The used symbols are defined as follows:
Bedeutung:
Warnung vor gefährlichen Situationen und Warning of hazardous situation and property
Sachschäden damage
Stellventile so lange wie möglich in ihrem Keep control valves as long as possible in their
Transportbehälter oder auf der Palette belassen transport containers or on pallets
Bei Lagerung der Geräte für länger als sechs When storing the units more than six months, see
Monate siehe Dokumentation EB005.045 documentation EB005.045
Anzugsdrehmomente für die Montage des Getriebes Tightening torques for mounting the gearbox and
und Handrads siehe VETEC Betriebsnorm hand wheel are published in VETEC Operating and
BN004.229 Maintenance Instructions BN004.229
Lasten dürfen nur durch entsprechend geschultes
Loads to be lifted and transported only by suitably
oder unterwiesenes Personal angehoben und
trained or instructed staff
transportiert werden
Lasten niemals in der Luft hängen lassen Never leave loads hanging in the air
Vor dem Anheben eines Stellventils das Gewicht Before lifting the control valves check the weight
anhand der technischen Dokumentation überprüfen according to the technical documentation
Stellventile immer am Lastschwerpunkt heben, um Lift the control valves always at the load center, to
unkontrolliertes Kippen zu verhindern prevent uncontrolled tipping
Stellventil in der gleichen Ausrichtung anheben, in Lift the control valve in the same orientation in which it
der es in die Rohrleitung eingebaut wird will be mounted into the pipeline
Vor dem Entfernen von Tragseilen, Tragegurten Before removing the lifting ropes, straps and / or
und/oder Trageketten kontrollieren, dass das Ventil support chains make sure, that the control valve is
fehlerfrei eingebaut wurde installed correctly
i h ll Remove the yellow protective caps from the valve
Die Schutzkappen an den Ventilanschlüssen dürfen
erst unmittelbar vor dem Einbau inlet and outlet shortly before assembling the valves in
des Ventils in die Rohrleitung entfernt werden the pipeline
EB005.050 Revision 01 Seite 3 von 7
EINBAU- UND BEDIENUNGSANLEITUNG
EB019.022
MOUNTING AND OPERATING INSTRUCTIONS
Hebeanweisung für Ventile mit montiertem Antrieb
Typ AT/
Lifting Instructions for Valves with mounted Actuator
Type AT
Abb.1/Fig.1
Abb.2/Fig.2
Abb.3/Fig.3
5. Heben von Ventilen mit montiertem Antrieb Typ AT / Lifting of Valves with
mounted Actuator Type AT
Abb.4/Fig.4
Abb.5/Fig.5
6. Heben von Ventilen mit montiertem Antrieb Typ AT und Getriebe (Handrad) /
Lifting of Valves with mounted Actuator Type AT and Gear Box (Hand Wheel)
Abb.7/Fig.7
EB005.045 Revision 0 1 2 3 4 5 6 7 8 9
Ersteller F.Thiede Revisor fth
Seite 1 von 9
Genehmigt P. Konzack Genehmigt ko
Datum 26.09.2016 Datum 26.09.16
EINBAUVORSCHRIFTEN
EB005.045
INSTALLATION INSTRUCTIONS
Anweisungen über die Lagerung von VETEC Produkten
beim Kunden/
Instructions for the Storage of VETEC Products
at the Customer
6. Wichtige Hinweise bezüglich Lagerung von Weichteilen / Important Notes on Soft Parts .... 7
1. Hinweise / Notes
Dieses Dokument beschreibt die Lagerbedin- This document describes the storing conditions
gungen und Lagerzeiten von Stellgeräten, and storing period of control units, accessories,
Zubehör, Ersatzteilen usw. wear parts etc.
Für Schäden und Betriebsstörungen, die durch For damages and operational breakdowns that
die Nichtbeachtung dieser Anweisung entste- are caused by noncompliance with these instruc-
hen, übernehmen wir keine Haftung. tions, we assume no liability.
Bei abweichenden Lagerbedingungen und Contact VETEC in case of different storage
längerer Lagerung Rücksprache mit VETEC conditions or long storage periods.
halten.
Die verwendeten Symbole haben folgende Used symbols are defined as follows:
Bedeutung:
Bitte beachten Sie folgende mitgeltenden Un- Please observe following applicable documents
terlagen für die Lagerung von VETEC Produk- for the storage of VETEC products:
ten:
Allgemeine Betriebsanleitung mit Si- General safety warnings and instructions
cherheits- und Gefahrenhinweisen on the relevant devices BN004.095
BN004.095
VETEC Transport Instructions for control
VETEC Transportanweisungen für units
Stellgeräte
Achtung! Die folgenden Punkten sind bei der Attention! Observe following instructions
Lagerung von VETEC Produkten (Ventile und when storing VETEC products (valves and actua-
Antriebe) unbedingt zu beachten: tors):
Um die Funktion der Stellgeräte in der In order to ensure the function of the con-
Anlage zu gewährleisten, führen Sie vor der trol unit in the plant, carry out a function test
Inbetriebnahme einen Funktionstest durch! before commissioning.
Ventile mit einer Nennweite größer als DN 150 Store all valves in sizes DN 150 (NPS 6) and lar-
(NPS 6) müssen in einer senkrechten Position ger in a vertical position with the actuator pointing
(Antrieb zeigt nach oben) gelagert werden, um up to prevent any damage to the seals (packing
Beschädigungen an den Abdichtungen (Pa- and pressure balancing).
ckungsraum) und Druckentlastung zu vermeiden.
Bei einer Lagerung von mindestens sechs Mona- If long-term storage (at least six months) is appli-
ten müssen alle Ventile mit einer Nennweite grö- cable, all sizes bigger than DN 50 (NPS 2) have
ßer als DN 50 (NPS 2) in senkrechter Position to be positioned in an upright position.
gelagert werden.
Unsachgemäße Krafteinwirkungen (z.B. treten) Improper force effects (e.g. to step on it) on the
auf die Steuerleitung und Anbauteile, sowie die control line and accessories, as well as the da-
Beschädigung durch Werkzeuge ist nicht zuläs- mages caused by tools are not allowed.
sig.
Lagerung der Armatur auf der Steuerleitung und Do not store the valve on the control line.
Anbauteilen ist unzulässig.
Die Flanschabdeckungen müssen auf dem Venti- Make sure the flange covers are mounted tightly
leingang und Ventilausgang dicht montiert sein on the valve inlet and outlet. Remove them im-
und sind erst unmittelbar vor dem Einbau zu ent- mediately before installation.
fernen.
Alle Produkte müssen trocken und gegen Wet- Store all VETEC products in a dry place. Protect
tereinflüsse geschützt, bei einer vorgegebenen, them against climatic influences. Make sure the
geräteabhängigen Umgebungstemperatur, gela- permissible ambient temperature specified for
gert werden. each product is not exceeded during storage (re-
fer to the associated technical specifications).
Bei Stellventilen in der Normalausführung beträgt The permissible storage temperature of standard
die zulässige Lagertemperatur -20 bis +65 °C. control valves is ̽20 to +65 °C.
Für andere Ausführungen sind die Lagertempera- Contact VETEC for the storage temperatures of
turen bei VETEC anzufragen. other valve versions.
Um die Kondensatbildung zu vermeiden, darf die To prevent condensate from forming, store the
relative Luftfeuchtigkeit von 75% nicht überschrit- products at a relative humidity less than 75 %.
ten werden.
Alle Produkte, die für einen Sauerstoffein- Remove all VETEC products marked for
satz gekennzeichnet sind, dürfen erst vor dem oxygen service from their packaging immediately
unmittelbaren Gebrauch / vor der Installation aus before use/installation.
ihrer Verpackung entnommen werden.
Achtung! Folgende Hinweise sind bei der Attention! Observe following instructions
Lagerung von Produkten unbedingt zu beachten: during the storage of products:
Bei längerer Lagerung ab sechs Monaten When storing products for longer periods of
sind die Produkte in ausreichend dicken Plastik- time (from six months on), pack them into plastic
beuteln und mit Trockenmittel in geschlossenen bags together with a desiccant and keep them in
Räumen aufzubewahren. enclosed rooms. Make sure the plastic bags are
sufficiently thick.
Es sollten regelmäßige Kontrollen etwa alle sechs Carry out regular checks (every six months) or
Monate oder bei Entnahme der Produkte aus upon removal of the products from the ware-
dem Lager durchgeführt werden. house.
Alle Produkte müssen trocken und gegen Wet- Store all products in a dry location at a relative
tereinflüsse geschützt bei einer relativen Luft- humidity less than 75 %. Protect them against
feuchtigkeit unter 75% gelagert werden. climatic influences.
Die Umgebungstemperatur muss produktabhän- Make sure the permissible ambient temperature
gig in dem spezifizierten Temperaturbereich lie- specified for each product is not exceeded during
gen (siehe auch technische Produktinformatio- storage (refer to the associated technical specifi-
nen). cations).
Die ideale Temperatur sollte +15°C betragen. Für The ideal temperature amounts to +15°C. The
elektronische Geräte sollte eine relative Luft- prevailing relative humidity should be below 75%
feuchtigkeit unter 75% sichergestellt sein. for electronic devices.
Die Umgebungsluft sollte frei von Säuren oder Make sure that the ambient air is free of acids or
anderen korrosiven und aggressiven Medien sein. other corrosive and aggressive media.
Elektronische Geräte wie z. B. Stellungsregler Do not stock electronic products (such as posi-
nicht bei einer Raumtemperatur über 25°C und in tioners) above room temperature (higher than
der Nähe von Wärmequellen wie Heizkörper, 25°C) and close to heat sources (radiators, heater
Heizrohren, usw. lagern. tubes, etc.).
Alle pneumatischen und elektrischen Anschlüsse Shut all pneumatic and electrical connections with
sind mit Kunststoffstopfen gegen Eindringen von blanking plugs to prevent dirt from getting inside
Schutz zu sichern und zu verschließen. Diese the products. Remove these blanking plugs im-
Kunststoffstopfen sind erst unmittelbar vor dem mediately before installation or start-up.
Einbau oder der Inbetriebnahme zu entfernen.
Deckel der Anbaugeräte, wie Stellungsregler oder Check that covers and lids on accessories (e.g.
Grenzsignalgeber, müssen korrekt geschlossen positioners, limit switches) are properly closed
und festgezogen sein. and tightened.
Die Lagerung und Konservierung von elektroni- The storage and preservation of electronic
schen Geräten (Zubehör) darf nur in Verbindung equipment (accessories) may be carried out only
mit den Anweisungen des Herstellers durchge- in accordance with the instructions of the manu-
führt werden. facturer.
Alle Produkte, die für einen Sauerstoffeinsatz Remove all products marked for oxygen
gekennzeichnet sind, dürfen erst vor dem unmit- service from their packaging immediately before
telbaren Gebrauch (vor der Installation) aus ihrer use/installation.
Verpackung entnommen werden.
Alle Gummiteile, wie z. B. Membranen, werden All rubber parts, for instance diaphragms, are
durch ultraviolettes Licht und Ozon beschädigt susceptible to damage (cracks) caused by ultra-
(Rissbildung). violet light and ozone.
Diese Teile sollten zum Schutz gegenüber These parts should be put in black plastic bags to
Licht/Sonnenlicht in schwarze Plastikbeutel ver- avoid any direct exposure to light/sun.
packt werden.
Gummiteile dürfen keiner Zugbelastung ausge- In addition, avoid that rubber parts are subjected
setzt werden. Sie sollten weder an einem Haken to any tensile stress-neither hang them on hooks
hängend noch in gefaltetem Zustand gelagert nor leave them folded (no deformation and ten-
werden. Keine Deformation oder Zugspannungen sion permitted).
sind erlaubt.
Gummiteile sind trocken zu lagern und Konden- Keep them dry (avoid condensation on the parts).
satbildung ist zu vermeiden.
Gummiteile nicht bei einer Raumtemperatur über Do not store soft parts above room temperature
25°C und in der Nähe von Wärmequellen wie (recommended +15°C) and not close to any heat
Heizkörper, Heizrohren, etc. lagern. Die empfoh- sources radiators, heater tubes, etc.
lene Lagertemperatur beträgt +15°C.
Gummiteile nicht zusammen mit Lösungsmitteln, Do not keep solvents, lubricants, chemicals and
Schmiermitteln, Chemikalien und Brennstoff la- fuel together with VETEC soft parts.
gern.
Verpackungsmaterial darf keine Substanzen aus- Packaging material must not release substances
dünsten, die Weichteile beschädigen (PVC ist als which damage soft parts (PVC not recommended
Verpackungsmaterial nicht empfehlenswert). PE- as packaging material). PE bags with a minimum
Beutel mit eine Mindestdicke von 0.075 mm soll- thickness of 0.075 mm may be used.
ten benutzt werden.
Empfehlungen Recommendation
Bei der Entnahme der Produkte aus dem La- Carry out regular checks or upon removal in
ger sollen Kontrollen durchgeführt werden. the warehousing and pay particular attention to:
Auf folgendes sollte geachtet werden:
Veränderungen auf der Oberfläche (ver- Changes on the surface (hardening, sof-
härten, aufweichen, klebrig werden) tening, stickiness)
Einleitung Introduction
Die Stellventile werden nach den Spezifikationen des Bestellers mit Antrieb und The control valves are supplied with actuators and accessories as required by the
Peripheriegeräten geliefert. Sie erfüllen die Anforderungen der europäischen customer's specifications.
Druckgeräterichtlinie 2014/68/EU. They fulfil the requirements of the European Pressure Equipment Directive
Die Einstufungen erfolgen als drucktragende Ausrüstungsteile oder Ausrüstungs- 2014/68/EU and are classified as pressure-bearing equipment or equipment with
teile mit Sicherheitsfunktion. safety function.
Die entsprechenden Konformitätserklärungen sind in der Technischen Dokumen- The relevant declarations of conformity are included in the technical documentation
tation der Geräte enthalten und können auch im Internet unter www.vetec.de ein- of the devices and are also available on the Internet at www.vetec.de.
gesehen werden. Plant operators must follow the Mounting and Operating Instructions as well as the
Betreiber müssen die Einbau- und Bedienungsanleitung sowie die Allgemeinen general safety warnings and instructions on the relevant devices.
Gefahren- und Sicherheitshinweise der betroffenen Geräte beachten.
Allgemeine Sicherheits- und Gefahrenhinweise General safety warnings and instructions
Die Stellventile dürfen nur durch fachkundiges und unterwiesenes Personal unter The control valves must be installed, started up, and serviced by trained and com-
Beachtung der anerkannten Regeln der Technik eingebaut, in Betrieb genommen petent staff in accordance with good engineering practices in such a way that em-
und gewartet werden. Dabei ist sicherzustellen, dass Beschäftigte oder Dritte nicht ployees and third persons are not exposed to danger.
gefährdet werden. Observe the relevant safety guidelines regarding the plant and the handling of haz-
Die einschlägigen Sicherheitsrichtlinien der Anlage, z. B. Ex-Schutz, ATEX, gefähr- ardous substances, as well as the explosion protection standards, ATEX directives,
liche Medien usw. sowie die Regeln der Technik sind bei Montage, dem Betrieb accepted industry codes, and good engineering practices, when installing, operat-
sowie Wartung und Instandsetzung zu beachten. ing, repairing, or servicing control valves.
Für Schäden, die durch äußere Kräfte oder äußere Einwirkungen entstehen, ist der The manufacturer does not assume any responsibility for damage caused by exter-
Hersteller nicht verantwortlich! nal forces or any other external factors.
Gefährdungen, die durch die Betriebs- und Umgebungsbedingungen sowie beweg- Take appropriate action to prevent any hazards that could be caused by the oper-
lichen Teilen ausgehen können, sind durch geeignete Maßnahmen zu verhindern. ating or environmental conditions or by moving parts.
Schutzmaßnahmen gegen externe Brände sind vom Betreiber zu treffen. The plant operator must take protective measures against external fire.
Bei Ventilen mit heißer Oberfläche sind Schutzmaßnahmen gegen Verbrennung Take the necessary protective measures as specified in DIN EN 563 to prevent burn
nach DIN EN 563 vorzunehmen. injuries from hot valve surfaces.
Sachgemäßer Transport und fachgerechte Lagerung der Stellventile gemäß den Make sure the control valves are shipped and stored properly in accordance with
üblichen einschlägigen Bestimmungen werden vorausgesetzt. the relevant provisions and regulations.
Die jeweiligen Gewichte sind den Lieferscheinen zu entnehmen. The weights are indicated in the shipping documents.
Bei Gebrauch von Handrädern oder Handnotbetätigungen am Antrieb ist unbedingt Strictly observe the operating instructions when operating the hand wheel or manual
die Bedienungsanleitung zu beachten, um Beschädigungen am Ventil-/Antriebs- override of the actuator to avoid damage to the control valve, manual gear, and
system bzw. Handgetriebe oder Handnotsystem zu vermeiden. manual override.
Bestimmungsgemäße Verwendung Intended use
VETEC Stellventile werden individuell gemäß den Auslegungsbedingungen, wie VETEC control valves are sized individually in accordance with the sizing criteria
Medium, Betriebsdruck und Betriebstemperatur des Bestellers ausgelegt. specified by the customer, such as the medium type, operating pressure, and oper-
Die bestimmungsgemäße Verwendung gemäß diesen Bedingungen ist sicherzu- ating temperature.
stellen. Make sure the control valves are used in compliance with the specified criteria.
Werden die Ventile unter abweichenden Betriebsbedingungen eingesetzt, so ist If the valves are to be used under different operating conditions, consult with VETEC
ggf. durch Rücksprache mit VETEC Ventiltechnik GmbH sicherzustellen, dass sie Ventiltechnik GmbH as necessary to be sure that the valves are suited for the in-
für diese Anforderungen geeignet sind. Eine Unterlassung dieser Eignungsprüfung tended use. Failure to check the valves for suitability may cause malfunctions re-
kann zu Fehlfunktionen und zu einer erheblichen Gefährdung von Personen, Gü- sulting in severe personal injury, equipment damage, and serious harm to the envi-
tern und der Umwelt führen ronment.
Ein- und Ausbau Installation and removal
Die Ventile sind unter Beachtung der anerkannten Technischen Regeln in die Rohr- Install the valves in the pipeline and then connect them to the air supply system and
leitung einzubauen und an die Leitungen für die Luftversorgung und das Stellsignal the control signal line, in compliance with good engineering practices.
anzuschließen. Note that too small a cross-sectional area of the air supply line or too low a supply
Zu geringe Zuluft- Leitungsquerschnitte oder ein zu geringer Zuluftdruck beein- pressure will impair the valve performance and functionality. Too high a supply pres-
trächtigen das Stellverhalten oder die Funktion. Ein zu hoher Zuluftdruck kann zu sure may cause damage to the actuator and accessories.
Schäden am Antrieb und den Peripheriegeräten führen. Prior to installing or removing the valve from the pipeline, isolate, drain, and depres-
Vor Montage bzw. Demontage der Ventile ist nach Anweisung des Betreibers der surize the relevant section of the pipeline, according to the instructions given by the
entsprechende Rohrleitungsabschnitt abzusperren, zu entleeren und zu entlüften. plant operator. Carry out the pressure test on the pipeline prior to installing the
Die Druckprüfung der Rohrleitung muss vor dem Einbau des Ventils erfolgen. Die valve. Carefully inspect the pipeline for remains from the installation, such as weld