Accesos online / Realtek PCIe GBE Family Controller / PLC_1 [192.168.0.1] / Bloques de programa
Main [OB1]
Main Propiedades
General
Nombre Main Número 1 Tipo OB Idioma KOP
Numeración automática
Información
Título "Main Program Sweep (Cy‐ Autor Comentario Familia
cle)"
Versión 0.1 ID personaliza‐
da

Main
Nombre Tipo de datos Valor predet. Comentario
Input
Initial_Call Bool
Remanence Bool
Temp
Constant

Segmento 1:

%I0.0 NORM_X SCALE_X


"boton start" UInt to Real Real to Int
EN ENO EN ENO
0 MIN %MD0 0 MIN %MW0
%IW64 OUT "Tag_3" %MD0 OUT "Tag_4"
"sensor" VALUE "Tag_3" VALUE
27648 MAX 100 MAX

%I0.0 DIV
"boton start" Real MOVE
EN ENO EN ENO
%MW0 %MW10 %MW10 %QD102
"Tag_4" IN1 OUT "Tag_9" "Tag_9" IN OUT1 "Tag_23"
10.0 IN2

Símbolo Dirección Tipo Comentario


"boton start" %I0.0 Bool
"sensor" %IW64 Int
"Tag_3" %MD0 Real
"Tag_4" %MW0 Int
"Tag_9" %MW10 Int
"Tag_23" %QD102 DWord

Segmento 2:

%I0.1 NORM_X SCALE_X


"stop" UInt to Real Real to Int
EN ENO EN ENO
0 MIN %MD1 0 MIN %MW1
%IW66 OUT "Tag_18" %MD1 OUT "Tag_19"
"Tag_26" VALUE "Tag_18" VALUE
27648 MAX 100 MAX

%I0.1 DIV
"stop" Real MOVE
EN ENO EN ENO
%MW1 %MW11 %MW11 %QD100
"Tag_19" IN1 OUT "Tag_10" "Tag_10" IN OUT1 "Tag_6"
10.0 IN2

Símbolo Dirección Tipo Comentario


"stop" %I0.1 Bool
"Tag_6" %QD100 Time
"Tag_10" %MW11 Int
"Tag_18" %MD1 Real
"Tag_19" %MW1 Int
"Tag_26" %IW66 UInt

Segmento 3:

ABS
Int
EN ENO
%MW0 %QW1000
"Tag_4" IN OUT "pwm"

Símbolo Dirección Tipo Comentario


"pwm" %QW1000 Int
"Tag_4" %MW0 Int
Totally Integrated
Automation Portal

Segmento 4:

%MW0
%I0.0 %M0.1
"Tag_4" "boton start" "cont down"
<=
Int
27

Símbolo Dirección Tipo Comentario


"boton start" %I0.0 Bool
"cont down" %M0.1 Bool
"Tag_4" %MW0 Int

Segmento 5:

%DB1
%I0.3 "CTRL_PWM_DB_1"
"Tag_12" CTRL_PWM
EN ENO
BUSY ...
266
"Pulse_2[PTO/ STATUS ...
PWM]" PWM
%I0.3
"Tag_12" ENABLE

Símbolo Dirección Tipo Comentario


"Pulse_2[PTO/PWM]" 266 HW_PWM
"Tag_12" %I0.3 Bool

Segmento 6:

%DB2
"IEC_Timer_0_DB"
%I0.0 %I0.1 %M0.1 TONR %M0.2
"boton start" "stop" "cont down" Time "cont up"
IN Q
%Q0.2 ET ...
"Tag_1" R
%QD100
"Tag_6" PT

%DB3
"IEC_Timer_0_
DB_1"

%M0.2 TOF %Q0.2


"cont up" Time "Tag_1"
IN Q
t#001ms PT ET ...

Símbolo Dirección Tipo Comentario


"boton start" %I0.0 Bool
"cont down" %M0.1 Bool
"cont up" %M0.2 Bool
"stop" %I0.1 Bool
"Tag_1" %Q0.2 Bool
"Tag_6" %QD100 Time

Segmento 7:

%MW1
%I0.1 %M0.4
"Tag_19" "stop" "Tag_24"
<=
Int
27

Símbolo Dirección Tipo Comentario


"stop" %I0.1 Bool
"Tag_19" %MW1 Int
"Tag_24" %M0.4 Bool

Segmento 8:
Totally Integrated
Automation Portal

%DB4
"IEC_Timer_0_
DB_3"

%I0.1 %I0.0 %M0.4 TONR %M0.3


"stop" "boton start" "Tag_24" Time "Tag_21"
IN Q
%Q0.4 ET ...
"Tag_14" R
%QD100
"Tag_6" PT

%DB5
"IEC_Timer_0_
DB_2"

%M0.3 TOF %Q0.4


"Tag_21" Time "Tag_14"
IN Q
t#001ms PT ET ...

Símbolo Dirección Tipo Comentario


"boton start" %I0.0 Bool
"stop" %I0.1 Bool
"Tag_6" %QD100 Time
"Tag_14" %Q0.4 Bool
"Tag_21" %M0.3 Bool
"Tag_24" %M0.4 Bool