Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Expansión Brusca
Expansión Brusca
Integrantes:
Gina Bello
Miguel Cuellar
Luis Miguel Infante
María Alejandra Jiménez
Omar Daniel Velandia
Presentado a:
Diana María Beltrán Beltrán
Bogotá D.C.
Tabla de contenido
Introducción ........................................................................................................................................ 3
Objetivos ............................................................................................................................................. 4
Marco Teórico ..................................................................................................................................... 5
Esquema del montaje.......................................................................................................................... 6
Datos ................................................................................................................................................... 7
Cálculos, Análisis y Resultados ............................................................................................................ 9
Procedimiento ............................................................................................................................. 9
Cálculos, resultados y análisis ..................................................................................................... 9
Conclusiones ..................................................................................................................................... 15
Bibliografía ........................................................................................................................................ 16
2
Introducción
Es de gran importancia entender las diferentes pérdidas localizadas que se encuentran en una
tubería, entre ellas, se encuentra la generada por una expansión brusca, que tal y como lo dice su
nombre es un cambio abrupto en el diámetro de una tubería de uno pequeño a uno grande, y es en
ese preciso punto en el cual se genera turbulencia y con esto una pérdida localizada, debido a los
esfuerzos cortantes.
3
Objetivos
1. Determinar las pérdidas de energía por medio de la ecuación de borda, cantidad de movimiento
y conservación de la masa.
2. Estudiar la línea piezométrica y de energía del sistema.
3. Verificar si la ecuación de Borda es satisfactoria
4
Marco Teórico
Para determinar las velocidades, se utilizará la expresión para caudal, despejando la velocidad en
términos de este y del área de la sección:
4𝑄
𝑉= (𝐸𝑐. 1)
𝜋𝐷 2
Para determinar la carga o cabeza de velocidad se eleva la ecuación 1 al cuadrado y se divide por 2
veces la gravedad, obteniendo la siguiente expresión:
𝑉2 8𝑄 2
= (𝐸𝑐. 2)
2𝑔 𝑔𝜋 2 𝐷 4
Para hallar la Línea de Energía, al tener las lecturas piezométricas, las cuales directamente nos dan
la Línea Piezométrica, se les suma la carga de velocidad, obteniendo la LE:
𝑃
𝐿𝑃 = 𝑍 +
𝛾
𝑉2
𝐿𝐸 = 𝐿𝑃 + (𝐸𝑐. 3)
2𝑔
Para determinar las pérdidas de energía se empleará la ecuación de Borda:
2 2
𝐴2 𝑉
Δℎ𝑒 = ( − 1) (𝐸𝑐. 4)
𝐴1 2𝑔
𝑝1 − 𝑝2 𝑣12 − 𝑣22
Δℎ𝑒 = + (𝐸𝑐. 5)
𝛾 2𝑔
2
𝑣12 − 𝑣22 1 𝐴1
Δℎ𝑒 = ( ) + (𝑝1 − 𝑝1′ ) (1 − ) (𝐸𝑐. 6)
2𝑔 𝛾 𝐴2
5
Esquema del montaje
El esquema presentado a continuación se realizó en AutoCad.
6
Datos
7
LECTURAS PIEZOMÉTRICAS (cm)
Medición
P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 P16 P17 P18 P19 P20
1 14.6 13.3 13.1 14.7 18.4 19.8 20.1 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.4
2 11.2 9.7 10.2 - - - - 16.4 - - - - - - - - - - -
3 - 21.1 21.7 - - - - 29.4 - - - - - - - - - - -
4 - 26.7 25.9 - - - - 35.7 - - - - - - - - - - -
5 - 34.8 34.2 - - - - 44.7 - - - - - - - - - - -
Tabla 1. Lecturas piezométricas
8
Cálculos, Análisis y Resultados
Procedimiento
Se identificará el comportamiento de la línea piezométrica con ayuda de los piezómetros, y se
supondrá el comportamiento del tubo de corriente en la expansión.
Por medio de la toma de cinco caudales diferentes, en los cuales hallan pequeños, medios y grandes,
para los cuales se deberá determinar: la sección de control de entrada y salida, y el volumen de
control. Luego, se tomarán las lecturas piezométricas a lo largo del sistema, para así poder trazar las
líneas de energía y piezométrica. Se calcularán las pérdidas de energía utilizando la ecuación de
Borda, la que tiene en cuenta la diferencia de presiones en la sección de control de entrada, y
realizar una comparación directa con los datos obtenidos en el laboratorio de las lecturas de los
piezómetros.
La sección de control de entrada se ubica entre los piezómetros P3 y P4; La sección de control de
salida, en el piezómetro P9 y el volumen de control entre los piezómetros P9 y P10.
9
Volumen Piezómetro Diámetro Alturas Piezométricas (cm) Velocidades (m/s) (Ec. 1) V²/2g (m/s) (Ec. 2) Alturas de energía (cm) (Ec. 3)
de control (m) Q1 Q2 Q3 Q4 Q5 V1 V2 V3 V4 V5 V_1 V_2 V_3 V_4 V_5 Q1 Q2 Q3 Q4 Q5
P2 0.0302 14.6 1.417 1.615 1.805 1.893 1.925 0.102 0.133 0.166 0.183 0.189 24.842
P3 0.0302 13.3 9.7 21.1 26.7 34.8 1.417 1.615 1.805 1.893 1.925 0.102 0.133 0.166 0.183 0.189 23.542 23.004 37.711 44.972 53.700
Entrada
P4 0.0302 13.1 10.2 21.7 25.9 34.2 1.417 1.615 1.805 1.893 1.925 0.102 0.133 0.166 0.183 0.189 23.342 23.504 38.311 44.172 53.100
P5 0.0493 14.7 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 16.142
P6 0.0493 18.4 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 19.842
P7 0.0493 19.8 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.242
P8 0.0493 20.1 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.542
Salida P9 0.0493 20.3 16.4 29.4 35.7 44.7 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742 18.273 31.739 38.273 47.361
P10 0.0493 20.3 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742
P11 0.0493 20.3 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742
P12 0.0493 20.3 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742
P13 0.0493 20.3 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742
P14 0.0493 20.3 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742
P15 0.0493 20.3 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742
P16 0.0493 20.3 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742
P17 0.0493 20.3 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742
P18 0.0493 20.3 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742
P19 0.0493 20.3 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.742
P20 0.0493 20.4 0.532 0.606 0.677 0.710 0.722 0.014 0.019 0.023 0.026 0.027 21.842
Tabla 4. Resultados para determinar la línea piezométrica
25
20
15
10
0
0 2 4 6 8 10 12 14 16 18 20
Perdidas de Energía.
Para la seccion de calculos de la perdida, se presentaros diferentes ecuaciones, el primer caso que se
tomo fue la ecuacion de Borda. Ecuacion que permite calcular perdidas de energia en funcion de la
geometria y de la velocidad del area expandida. En los siguientes recuadros se hallo la perdida para cada
uno de los diferentes caudales.
Pérdidas para Q1
Volumen Velocidad Δhe (m)
Área (m²) Δhe (cm)
de control 2 (m/s) (Ec.4)
Entrada 0.00071631
0.532 0.03995916 3.99591557
Salida 0.0019089
Ilustración 4. Pérdidas de energía para el caudal 1.
Pérdidas para Q2
Volumen Velocidad Δhe (m)
Área (m²) Δhe (cm)
de control 2 (m/s) (Ec.4)
Entrada 0.00071631
0.606 0.05190723 5.19072262
Salida 0.0019089
Ilustración 5.Pérdidas de energía para el caudal 2.
Pérdidas para Q3
Volumen Velocidad Δhe (m)
Área (m²) Δhe (cm)
de control 2 (m/s) (Ec.4)
Entrada 0.00071631
0.677 0.06480852 6.48085214
Salida 0.0019089
Ilustración 6. Pérdidas de energía para el caudal 3.
Pérdidas para Q4
Volumen Velocidad Δhe (m)
Área (m²) Δhe (cm)
de control 2 (m/s) (Ec.4)
Entrada 0.00071631
0.710 0.07129043 7.12904318
Salida 0.0019089
Ilustración 7. Pérdidas de energía para el caudal 4.
Pérdidas para Q5
Volumen Velocidad Δhe (m)
Área (m²) Δhe (cm)
de control 2 (m/s) (Ec.4)
Entrada 0.00071631
0.722 0.07373721 7.37372142
Salida 0.0019089
Ilustración 8. Pérdidas de energía para el caudal 5.
Cuando se aplica la ecuacion de cantidad de movimiento lineal al volumen de control, las variables
importantes son las presiones de la entrada (P y P’), asi como las velocidades, las caracteristicas
geometircas y las propiedades intrinsecas del fluido. En los siguientes recuadros se hallo la perdida para
cada uno de los diferentes caudales.
12
Pérdidas para
Q4
Volumen de Velocidad
Área m2 Δhe (m) Δhe (cm)
control 2 (m/s)
Entrada 0,00071631
0,710 0,07134138 7,13413798
Salida 0,0019089
Pérdidas para
Q5
Volumen de Velocidad
Área m2 Δhe (m) Δhe (cm)
control 2 (m/s)
Entrada 0,00071631
0,722 0,07377543 7,37754252
Salida 0,0019089
Cuando se aplica la ecuacion de energia al volumen de control, las variables importantes son las
presiones de la entrada y la salida, asi como las velocidades y las propiedades intrinsecas del fluido. En
los siguientes recuadros se hallo la perdida para cada uno de los diferentes caudales.
13
Pérdidas para
Q4
Volumen de Velocidad
Área m2 Δhe (m) Δhe (cm)
control 2 (m/s)
Entrada 0,00071631
0,710 0,07123863 7,12386304
Salida 0,0019089
Pérdidas para
Q5
Volumen de Velocidad
Área m2 Δhe (m) Δhe (cm)
control 2 (m/s)
Entrada 0,00071631
0,722 0,07377545 7,37754489
Salida 0,0019089
Los cálculos de la perdida con cada una de las ecuaciones se aproximan, mostrando la buena correlación
y la derivación que tiene la ecuación de borda en las ecuaciones de energía u cantidad de movimiento
ec 4 ec 5 ec 5
Q1 Δhe (cm) Δhe (cm) Δhe (cm)
14
Conclusiones
15
Bibliografía
[1]. Hidráulica experimental. Quinta edición. Ing. Héctor Alfonso Rodríguez Días
16