Está en la página 1de 10

Planificación de Revestidores Año 2009 (PETROWAYU S.A.

) 22-09-09

Pozo C-338 (CRETACEO)

Tipo Revestidor OD Peso (Lbs/pie) Grado Rosca Longitud (Pies) Total Longitud (Pies) Juntas Aprox. Fecha de Entrega Solped Comentario
Superficial 13 3/8" 54.5 K-55 BTC 500 500 13 10/15/2009 BARIVEN
Intermedio 9 5/8" 36 J-55 BTC 3000 3000 75 10/15/2009 BARIVEN
Producción 7" 26 N-80 BTC 7000 175 N/A En Almacen (Comprada a Petrosiven)
Producción 7" 29 N-80 BTC 2700 11700 68 10/30/2009 BARIVEN
Producción 7" 29 P-110 BTC 2000 50 10/30/2009 BARIVEN
Liner de Producción 5" 15 N-80 STL 1800 1800 45 N/A En Almacen PTW
Tubing de Producción 2-7/8" 6.4 N-80 EUE 11500 11500 383 11/15/2009 BARIVEN

Pozo C-337 (BASAMENTO)

Tipo Revestidor OD Peso (Lbs/pie) Grado Rosca Longitud (Pies) Total Longitud (Pies) Juntas Aprox. Fecha de Entrega Solped Comentario
Superficial 20" 94 K-55 BTC 500 500 13 10/15/2009 BARIVEN
Intermedio 13 3/8" 68 N-80 BTC 3000 75 N/A En almacen (Comprada a Tenaris)
4500
Intermedio 13 3/8" 72 P-110 BTC 1500 38 10/15/2009 BARIVEN
Producción 9 5/8" 47 N-80 BTC 6600 165 11/1/2009 BARIVEN
11000
Producción 9 5/8" 53.5 P-110 BTC 4400 110 N/A En almacen (Comprada a Tenaris)
Liner de Producción 7" 29 P-110 BTC 1800 1800 45 11/15/2009 BARIVEN
Liner de Producción 5" 15 N-80 STL 1200 1200 30 N/A En Almacen PTW
Tubing de Producción 2-7/8" 6.4 N-80 EUE 11800 11800 393 11/30/2009 BARIVEN

Pozo C-339 (CRETACEO)

Tipo Revestidor OD Peso (Lbs/pie) Grado Rosca Longitud (Pies) Total Longitud (Pies) Juntas Aprox. Fecha de Entrega Solped Comentario
Superficial 13 3/8" 54.5 K-55 BTC 500 500 13 12/20/2009 BARIVEN
Intermedio 9 5/8" 36 J-55 BTC 3000 75 12/30/2009 BARIVEN
4500
Intermedio 9 5/8" 47 N-80 BTC 1500 38 12/30/2009 BARIVEN
Producción 7" 26 N-80 BTC 7000 175 1/15/2009 BARIVEN
Producción 7" 29 N-80 BTC 2700 11700 68 1/15/2009 BARIVEN
Producción 7" 29 P-110 BTC 2000 50 1/15/2009 BARIVEN
Liner de Producción 5" 15 N-80 STL 1800 1800 45 N/A En Almacen PTW
Tubing de Producción 2-7/8" 6.4 N-80 EUE 11500 11500 383 1/20/2009 BARIVEN

WWQ-4 (EOCENO)

Tipo Revestidor OD Peso (Lbs/pie) Grado Rosca Longitud (Pies) Total Longitud (Pies) Juntas Aprox. Fecha de Entrega Solped Comentario
Superficial 9 5/8" 47 N-80 BTC 1000 1000 25 10/15/2009 BARIVEN
Intermedio 7" 26 N-80 BTC 3500 3500 88 10/15/2009 BARIVEN
Liner de Producción 5" 15 N-80 STL 1200 1200 30 10/15/2009 En Almacen PTW
Tubing de Producción 2-7/8" 6.4 N-80 EUE 3500 3500 117 10/15/2009 BARIVEN

WWQ-5 (EOCENO)

Tipo Revestidor OD Peso (Lbs/pie) Grado Rosca Longitud (Pies) Total Longitud (Pies) Juntas Aprox. Fecha de Entrega Solped Comentario
Superficial 9 5/8" 47 N-80 BTC 1000 1000 25 10/30/2009 BARIVEN
Intermedio 7" 26 N-80 BTC 3500 3500 88 10/30/2009 BARIVEN
Liner de Producción 5" 15 N-80 STL 1200 1200 30 10/30/2009 En Almacen PTW
Tubing de Producción 2-7/8" 6.4 N-80 EUE 3500 3500 117 10/30/2009 BARIVEN
Tubería para Workover Año 2009 (PETROWAYU S.A.)

Pozo C-270

Tuberia Diametro Externo Peso (Lbs/pie) Grado Rosca Longitud (Pies) Juntas Aprox. Fecha de Entrega Solped
Producción 2-7/8" 6.4 N-80 EUE 8rd 11500 383 9/25/2009

Pozo C-271

Tuberia Diametro Externo Peso (Lbs/pie) Grado Longitud (Pies) Cantida de Juntas Aprox. Fecha de Entrega Solped
Producción 3-1/2" 9.3 N-80 EUE 8rd 9500 317 11/20/2009

Pozo C-310

Tuberia Diametro Externo Peso (Lbs/pie) Grado Longitud (Pies) Cantida de Juntas Aprox. Fecha de Entrega Solped
Producción 2-7/8" 6.4 N-80 EUE 8rd 11500 383 9/15/2009

Pozo C-325

Tuberia Diametro Externo Peso (Lbs/pie) Grado Longitud (Pies) Cantida de Juntas Aprox. Fecha de Entrega Solped
Producción 2-7/8" 6.4 N-80 EUE 8rd 9500 317 10/15/2009
BARIVEN

BARIVEN

BARIVEN

BARIVEN
RESUMEN 2009 (22-09-09)

Pies de TBG Total Juntas

REV 20", 94LB/FT, K-55 BTC R3 575 14


REV 13-3/8", 54.5 LB/FT, K-55 BTC R3 1,150 29
REV 13-3/8", 68 LB/FT, N-80 BTC R3 1,150 29
REV 13-3/8", 72 LB/FT, P-110 BTC R3 1,725 43
REV 9-5/8", 36 LB/FT, J-55 BTC R3 6,900 172
REV 9-5/8", 47 LB/FT, N-80 BTC R3 11,615 290
REV 9-5/8", 53,5 LB/FT, P-110 BTC R3 575 14
REV 7", 26 LB/FT, N-80 BTC R3 16,100 402
REV 7", 29 LB/FT, N-80 BTC R3 6,210 155
REV 7", 29 LB/FT, P-110 BTC R3 6,670 167
REV 5", 15 LB/FT, N-80 STL R3 (PRE-PERFORADO) - -
TBG 2-7/8", 6.4 LB/FT, N-80 EUE 8rd R2 48,070 1,202
RA/RC
TBG 2-7/8", 6.4 LB/FT, N-80 EUE 8rd R2 32,500 1,083
TBG 3-1/2", 9.3LB/FT, N-80 EUE 8rd R2 9,500 317
35

43

300

3 120

13,000 LBS
AÑO 2009 (SEPTIEMBRE)

EQUIPO ENE FEB MAR ABR MAY JUN JUL AGO SEP OCT NOV DIC
SAI-
SAI-629 DZGL-1 MTTO DZGL-1 DNJL-1 FOQL-2
1500 HP ( C-335 ) TALADRO ( C-335 ) ( C-336 ) ( C-338 )
CRET NORTE CRET NORTE CRET SUR

F 29 CUQL-2 DGNL-2
2000 HP ( C-337 ) ( C-339 )
BAS NORTE CRET NORTE

COROD / C-188 C-267 C-005 C-197 C-317 C-215 C-288


C-184 C-317 C-182 C-182 C-179
CABILLERO C-208 C-182 C-256 C-051 C-180 C-266
C-302 C-208
MEDICION / C-265
C-331
GRADIENTE C-264 C-279
C-051
C-332 C-285
MEDICION / C-323 C-305 C-310
GRADIENTE C-314
C-192 C-227

COILED
C-335 C-315
TUBING/EST.

PETREX 5802
C-270 WWQ-4 WWQ-5 C-310
1000 HP

W 32 C-121 C-286 C-275 C-317


(CABILLERO C-284 C-164 C-163 C-005
/PULLING) C-184 C-297 C-267

BOHAI
C-271 C-325
750 HP
POZO C-336
CUQL-2 (DNJL-1)
(C-337 / C-313-2) FOQL-2 (C-338) WWQ-4 WWQ-5 DGNL-2 (C-339)
20" 94#/FT K-55 BTC. 500'.
Ubicada con Bariven.
Gestionando Reserva y 500' 13-5/8" 54,5#/FT N-80
Transporte. BTC @ 550. Bariven ofrece
500 500 sustituto con costura. 500
9-5/8" 47#/FT N-80
BTC @ 550'.
11000' Tbg 2-7/8" 6,4#/FT N-80
EUE. Bariven espera
disponibilidad para la fecha 3000' 9-5/8" 36#/FT N-80
estimada. 3000' Tbg 2-7/8"
BTC @ 2812. Ubicada con
6,4#/FT N-80 EUE
Bariven. Gestionando
Reserva y Transporte
3200
3000' 13-3/8" 68#/FT N-80 BTC. 7" 26#/FT N-80 BTC
Tubería en CATM. Compra @ 3500'.
consolidada a TENARIS 1500' 9-5/8" 47 #/FT N-80
BTC. Bariven ofrece
sustituto 53,5 #/ft. Por
confirmar drift especial. 5" 15#/FT N-80 STL.

1500' 13-3/8" 72#/FT P-110


4500 BTC. Bariven solicitó a
4500 4200
otras áreas espera
confirmación de 10.500' Tbg 2-7/8" 6,4#/FT N-
disponibilidad. 80 EUE. Bariven espera
disponibilidad para la fecha
estimada.
6600' 9-5/8" 47#/FT N-80
BTC. Bariven ofrece 3000' 7" 29#/FT N-80 BTC.
sustituto 53,5 #/ft. Por 7000' 7" 26#/FT N-80 BTC.
confirmar drift especial. Tubería CATM. Compra a
Petrosiven.

3000' 7" 29#/FT N-80 BTC.


Bariven ofrece sustituto Con
4400' 9-5/8" 53,5#/FT N-80 costura rosca STL.
BTC. Tubería en CATM.
1500' 7" 29#/FT P-110 BTC.
Compra consolidada a
Bariven ofrece sustituto
TENARIS
1500' 7" 29#/FT P-110 BTC. rosca 513
Bariven ofrece sustituto
rosca 513
11000 11000
7" 29#/FT P-1110 BTC.
1500'. Bariven ofrece
sustituto con 513 HYD.
Gestionando Reserva y
Transporte. Faltan Cross 5" 15#/FT N-80 STL. '. 5" 15#/FT N-80 STL. '.
overs para equipos de Tubería CATM. Tubería CATM.
flotación

12500 12500

5" 15#/FT N-80 STL. '.


Tubería CATM.

13500
DGNL-2 (C-339)

500' 13-5/8" 54,5#/FT N-80


BTC @ 550. Bariven ofrece
sustituto con costura.

3000' 9-5/8" 36#/FT N-80


BTC

1500' 9-5/8" 47 #/FT N-80


BTC.

7000' 7" 26#/FT N-80 BTC.

3000' 7" 29#/FT N-80 BTC.

10.500' Tbg 2-7/8" 6,4#/FT


N-80 EUE. Bariven espera
disponibilidad para la
fecha estimada.

1500' 7" 29#/FT P-110 BTC.


Bariven ofrece sustituto
rosca 513

5" 15#/FT N-80 STL. '.


Tubería CATM.