Está en la página 1de 4

REPORTE DE ANALISIS VIBRACIONAL

Análisis Vibracional Agosto 2007

TABLA DE CONTENIDO
PLANTA: Estación de Compresión Chillijchi ....................................................................... 1
Puntos de Medición: ........................................................................................................... 1
CODIGO DE MAQUINA: UCG#1 ................................................................................... 2
Figura 1. ........................................................................................................................ 3
Figura 2. ........................................................................................................................ 3
Figura 3. ........................................................................................................................ 4

CLIENTE: TRANSREDES S.A.

PLANTA: Estación de Compresión Chillijchi

Puntos de Medición:

F7H Al fan

F5H F6H

Urbanización Ciudad Jardín


Calle Los Tulipanes # 37
Tel/Fax: (5913) 345 9724
Fax: (591) 721 23894
e-mail: ramiroleon@entelnet.bo
rleon0103@gmail.com
Santa Cruz, Bolivia Página 1 de 4
REPORTE DE ANALISIS VIBRACIONAL
Análisis Vibracional Agosto 2007

CODIGO DE MAQUINA: UCG#1


FECHA: 24-AGO-07 CRITICIDAD:

Características Vibracionales:
Los niveles vibracionales están algo elevados en estos rodamientos, en particular en
los rodamientos del tesador con amplitudes elevadas en los picos a 2xRPM del mismo.
En el caso del rodamiento del FinFan, se observa un levantamiento del espectro en
las bajas frecuencias, con un pico dominante a 61 Hz.

Diagnóstico:
Este comportamiento es indicación de una desalineación en el tesador
Indicación de soltura en este rodamiento

Recomendaciones:
Revisar y corregir la alineación de la polea con relación a las otras dos
Monitorear el comportamiento después de la corrección de la alineación de la polea
del tesador

Urbanización Ciudad Jardín


Calle Los Tulipanes # 37
Tel/Fax: (5913) 345 9724
Fax: (591) 721 23894
e-mail: ramiroleon@entelnet.bo
rleon0103@gmail.com
Santa Cruz, Bolivia Página 2 de 4
REPORTE DE ANALISIS VIBRACIONAL
Análisis Vibracional Agosto 2007

TRDS_Chillijchi Unidad #1; W aukesha L5794 GSI Brg OB - Tesador Run 1 Channel 1 FFT at 20.00 Hz 08/24/07 08:20

Overall = 0.4768 Peaks


0.4 # Mag. Freq.
X: 29.297 01 = 0.362 @ 48.8

1
Y: 0.09402 02 = 0.179 @ 70.8
03 = 0.177 @ 61.0
04 = 0.138 @ 119.6
05 = 0.094 @ 29.3
06 = 0.058 @ 41.5
07 = 0.038 @ 100.1
0.3 08 = 0.020 @ 90.3
09 = 0.019 @ 80.6
10 = 0.019 @ 109.9
i n/ sec

0.2
32

0.1 5

6
7
98 10

00 1000 2000
Frequency (Hz)

Figura 1. Espectro Vibracional Rodamiento Tesador, lado ataque (Motor)

TRDS_Chillijchi Unidad #1; W aukesha L5794 GSI Brg IB - Tesador Run 1 Channel 1 FFT at 20.00 Hz 08/24/07 08:21

Overall = 0.3133 Peaks


0.3 # Mag. Freq.
X: 01 = 0.270 @ 48.8
Y: 02 = 0.097 @ 61.0
1 03 = 0.083 @ 70.8
04 = 0.058 @ 119.6
05 = 0.038 @ 39.1
06 = 0.037 @ 90.3
07 = 0.034 @ 29.3
08 = 0.025 @ 80.6
09 = 0.014 @ 109.9
10 = 0.013 @ 139.2
0.2
i n/ s e c

0.1 2
3

5
7 6
8
9 10

00 1000 2000
Frequency (Hz)

Figura 2. Espectro Vibracional Rodamiento Tesador, lado opuesto

Urbanización Ciudad Jardín


Calle Los Tulipanes # 37
Tel/Fax: (5913) 345 9724
Fax: (591) 721 23894
e-mail: ramiroleon@entelnet.bo
rleon0103@gmail.com
Santa Cruz, Bolivia Página 3 de 4
REPORTE DE ANALISIS VIBRACIONAL
Análisis Vibracional Agosto 2007

TRDS_Chillijchi Unidad #1; W aukesha L5794 GSI Brg IB - Fin Fan Run 1 Channel 1 FFT at 20.00 Hz 08/24/07 08:21
0.10
Overall = 0.1591 Peaks
# Mag. Freq.
X: 01 = 0.085 @ 61.0
Y: 02 = 0.060 @ 70.8
1 03 = 0.059 @ 51.3
04 = 0.047 @ 90.3
05 = 0.032 @ 119.6
06 = 0.029 @ 29.3
07 = 0.028 @ 80.6
08 = 0.025 @ 39.1
09 = 0.016 @ 100.1
10 = 0.011 @ 109.9
32
i n/ sec

0.05
4

5
6 7
8

9
10

00 1000 2000
Frequency (Hz)

Figura 3. Espectro Vibracional Rodamiento FinFan

Urbanización Ciudad Jardín


Calle Los Tulipanes # 37
Tel/Fax: (5913) 345 9724
Fax: (591) 721 23894
e-mail: ramiroleon@entelnet.bo
rleon0103@gmail.com
Santa Cruz, Bolivia Página 4 de 4

También podría gustarte