1. DATOS
2. PREDIMENSIONAMIENTO
H1 = 4.40 m
H2 = 1.15 m GEOMETRIA
H3 = 0.20 m
H4 = 0.20 m 6.50
H5 = 0.20 m 6.00
5.50
H6 = 0.95 m
5.00
H7 = 0.40 m
4.50
H8 = 3.60 m
4.00
hz = 0.70 m
3.50 MURO
h= 5.55 m 3.00
B= 4.30 m 2.50 RELLENO
B1 = 1.20 m 2.00
B2 = 2.60 m 1.50
T= 0.50 m 1.00
t= 0.25 0.50
N= 0.45 m 0.00
b= 0.30 m 0.00 1.00 2.00 3.00 4.00 5.00
w= 0.20 m
INFORME
REFORMULACIÓN DEL EXPEDIENTE TÉCNICO DE LA INVERSIÓN:
FINAL
“MEJORAMIENTO DEL PUENTE VEHICULAR Y PEATONAL DE
EXP-PP-001
PIQUECOCHA, DISTRITO DE VITIS, PROVINCIA DE YAUYOS – LIMA”
Rev_01
Peso x Mx y My
Elemento
ton m ton-m m ton-m
1 7.22 2.15 15.53 0.35 2.53
2 4.32 1.45 6.26 2.50 10.80
3 1.44 1.58 2.27 4.70 6.77
4 0.83 1.55 1.28 5.68 4.70
5 0.14 1.80 0.26 5.95 0.86
ΣFv = 13.96 ΣM = 25.61 ΣM = 25.65
P DC = 11.74 ton
P DW = 1.05 ton
Peso x Mx y My
Elemento
ton m ton-m m ton-m
6 1.58 1.83 2.89 2.50 3.96
7 22.95 3.13 71.73 3.48 79.77
ΣFv = 24.54 ΣM = 74.62 ΣM = 83.73
Ka = 0.308
EH = 10.60 ton
EHv = 1.84 ton
EHh = 10.44 ton
heq = 0.64 m
ωLS = 1.13 ton/m2
LSv = 2.93 ton
LSh = 2.17 ton
BR = 4.15 ton
EQ = 5.12 ton
KAE = 0.454
EAE = 15.62 ton
ΔEAE = 5.18 ton
INFORME
REFORMULACIÓN DEL EXPEDIENTE TÉCNICO DE LA INVERSIÓN:
FINAL
“MEJORAMIENTO DEL PUENTE VEHICULAR Y PEATONAL DE
EXP-PP-001
PIQUECOCHA, DISTRITO DE VITIS, PROVINCIA DE YAUYOS – LIMA”
Rev_01
DC DC super DW EV LL+IM EH LS EQ BR
Resistencia Ia 1.25 1.25 1.50 1.35 1.75 1.50 1.75 0.00 1.75
Resistencia Ib 0.90 0.90 0.65 1.00 0.00 1.50 1.75 0.00 1.75
Evento Extremo I 1.00 1.00 1.00 1.00 0.00 1.00 0.00 1.00 0.00
Servicio I 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00
Cargas verticales Vu
DC DC super DW EV LL+IM EH LS Vu
13.96 11.74 1.05 24.54 31.65 1.84 2.93 87.70
Resistencia Ia 17.45 14.68 1.58 33.13 55.39 2.76 5.13 130.10
Resistencia Ib 12.56 10.57 0.68 24.54 0.00 2.76 5.13 56.23
Evento Extremo I 13.96 11.74 1.05 24.54 0.00 1.84 0.00 53.13
Servicio I 13.96 11.74 1.05 24.54 31.65 1.84 2.93 87.70
Cargas horizontales Hu
4.2.1 EXCENTRICIDAD
4.2.3 DESLIZAMIENTO
N Fr = μN ϕτ Fr Fh verificación Indice
ton ton ton ton Fh < ϕτ Fr D/C
Resistencia Ia 130.10 78.06 62.45 26.73 Ok 43%
Resistencia Ib 56.23 33.74 26.99 26.73 Ok 99%
Evento Extremo I 53.13 31.88 31.88 25.85 Ok 81%
Servicio I 87.70 52.62 52.62 16.76 Ok 32%
REFORMULACIÓN DEL EXPEDIENTE TÉCNICO DE LA INVERSIÓN: INFORME FINAL
“MEJORAMIENTO DEL PUENTE VEHICULAR Y PEATONAL DE PIQUECOCHA, EXP-PP-001
DISTRITO DE VITIS, PROVINCIA DE YAUYOS – LIMA”
Rev: 01
DC EV EH LS EQ terr EQ inercial
Resistencia Ia 1.25 1.35 1.50 1.75 0.00 0.00
Resistencia Ib 0.90 1.00 1.50 1.75 0.00 0.00
Evento Extremo I 1.00 1.00 1.00 0.00 1.00 1.00
Servicio I 1.00 1.00 1.00 1.00 0.00 0.00
Cargas verticales Vu
DC EV EH LS Vu
13.96 24.54 1.84 2.93 43.26
Resistencia Ia 17.45 33.13 2.76 5.13 58.46
Resistencia Ib 12.56 24.54 2.76 5.13 44.99
Evento Extremo I 13.96 24.54 1.84 0.00 40.34
Servicio I 13.96 24.54 1.84 2.93 43.26
DC EV EH LS Mvu
25.61 74.62 7.92 8.79 116.93
Resistencia Ia 32.01 100.74 11.88 15.38 160.00
Resistencia Ib 23.05 74.62 11.88 15.38 124.92
Evento Extremo I 25.61 74.62 7.92 0.00 108.15
Servicio I 25.61 74.62 7.92 8.79 116.93
Cargas horizontales Hu
LS EH EQ terr EQ inercial Vh
2.17 10.44 2.59 7.70 22.90
Resistencia Ia 3.80 15.66 0.00 0.00 19.46
Resistencia Ib 3.80 15.66 0.00 0.00 19.46
Evento Extremo I 0.00 10.44 2.59 7.70 20.73
Servicio I 2.17 10.44 0.00 0.00 12.61
5.2.1 EXCENTRICIDAD
5.2.3 DESLIZAMIENTO
N Fr = μN ϕτ Fr Fh verificación Indice
ton ton ton ton Fh < ϕτ Fr D/C
Resistencia Ia 58.46 35.08 28.06 19.46 Ok 69%
Resistencia Ib 44.99 26.99 21.59 19.46 Ok 90%
Evento Extremo I 40.34 24.20 24.20 20.73 Ok 86%
Servicio I 43.26 25.96 25.96 12.61 Ok 49%
INFORME
REFORMULACIÓN DEL EXPEDIENTE TÉCNICO DE LA INVERSIÓN: FINAL
“MEJORAMIENTO DEL PUENTE VEHICULAR Y PEATONAL DE EXP-PP-001
PIQUECOCHA, DISTRITO DE VITIS, PROVINCIA DE YAUYOS – LIMA”
Rev: 01
6. CARGAS DE DISEÑO
Ka = 0.308
EH = 8.36 ton
EHv = 1.45 ton
EHh = 8.23 ton
KAE = 0.454
EAE = 12.32 ton
ΔEAE = 4.08 ton
Resumen de cargas
6.2 ZAPATA
Resumen de cargas
7. COMBINACIONES DE CARGA
LS EH EQ terr EQ super BR DC EV
Resistencia I 1.75 1.50 0.00 0.00 1.75 1.25 1.35
Evento Extremo I 0.00 1.00 1.00 1.00 0.00 1.00 1.00
Servicio I 1.00 1.00 0.00 0.00 1.00 1.00 1.00
LS EH EQ terr EQ super BR Mu
ton-m ton-m ton-m ton-m ton-m ton-m
5.35 15.23 13.60 25.45 23.03 82.67
Resistencia I 9.36 22.85 0.00 0.00 40.31 72.52
Evento Extremo I 0.00 15.23 13.60 25.45 0.00 54.28
Servicio I 5.35 15.23 0.00 0.00 23.03 43.62
DC EV LS ω suelo Mu
ton-m ton-m ton-m ton-m ton-m
5.68 32.91 3.81 42.39
Resistencia I 7.10 44.43 6.66 1.53 59.72
Evento Extremo I 5.68 32.91 0.00 -7.45 31.14
Servicio I 5.68 32.91 3.81 -27.84 14.56
ωu B1 Mu
ton/m m ton-m
Resistencia I 35.75 1.20 25.74
Evento Extremo I 35.14 1.20 25.30
Servicio I 40.77 1.20 29.35
REFORMULACIÓN DEL EXPEDIENTE TÉCNICO DE LA INVERSIÓN: INFORME FINAL
“MEJORAMIENTO DEL PUENTE VEHICULAR Y PEATONAL DE EXP-PP-001
PIQUECOCHA, DISTRITO DE VITIS, PROVINCIA DE YAUYOS – LIMA”
Rev: 01
Recubrimiento:
C° en contacto con el terreno 5.00 cm
Mu = 72.52 ton-m
fr = 29 kg/cm2
S= 41,667 cm3
1.2 Mcr = 14.44 ton-m
4/3 Mu = 96.70 ton-m
M min = 14.44 ton-m
Colocamos: # 8 @ 15 cm +
# 6 @ 15 cm
Recubrimiento:
C° en contacto con el terreno 7.50 cm
Mu = 59.72 ton-m
fr = 29 kg/cm2
S= 81,667 cm3
1.2 Mcr = 28.29 ton-m
4/3 Mu = 79.62 ton-m
M min = 28.29 ton-m
Colocamos: # 6 @ 20 cm +
# 6 @ 20 cm
Recubrimiento:
C° en contacto con el terreno 7.50 cm
Mu = 25.74 ton-m
fr = 29 kg/cm2
S= 81,667 cm3
1.2 Mcr = 28.29 ton-m
4/3 Mu = 34.32 ton-m
M min = 28.29 ton-m
Colocamos: # 6 @ 20 cm
# 6 @ 20 cm
Recubrimiento:
C° en contacto con el terreno 5.00 cm
Mu = 54.28 ton-m
fr = 29 kg/cm2
S= 41,667 cm3
1.2 Mcr = 14.44 ton-m
4/3 Mu = 72.38 ton-m
M min = 14.44 ton-m
Colocamos: # 8 @ 20 cm +
# 6 @ 25 cm
Recubrimiento:
C° en contacto con el terreno 7.50 cm
Mu = 31.14 ton-m
fr = 29 kg/cm2
S= 81,667 cm3
1.2 Mcr = 28.29 ton-m
4/3 Mu = 41.52 ton-m
M min = 28.29 ton-m
Colocamos: # 6 @ 20 cm +
# 6 @ 20 cm
Recubrimiento:
C° en contacto con el terreno 7.50 cm
Mu = 25.30 ton-m
fr = 33 kg/cm2
S= 81,667 cm3
1.2 Mcr = 32.67 ton-m
4/3 Mu = 33.74 ton-m
M min = 32.67 ton-m
Colocamos: # 6 @ 20 cm
# 6 @ 20 cm
Ec = 219,964 kg/cm2
Es = 2,100,000 kg/cm2
𝐸𝑠
n= 9 𝑛=
𝐸𝑐
As = 52.93 cm2/m Acero dispuesto
nAs = 476.40 cm2/m
𝑏𝑥 2
= 𝑛𝐴𝑠 (𝑑 − 𝑥)
2
x= 16.20 cm
𝑏𝑥 3
𝐼𝑐𝑟 = + 𝑛𝐴𝑆 (𝑑 − 𝑥)2
3
Icr = 502,782 cm4/m
0.6 fy = 2,520 kg/cm2
𝑛𝑀𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜 (𝑑 − 𝑥)
𝑓𝑠 =
𝐼𝑐𝑟
fs = 2,150 kg/cm2 fs < 0.6 fy OK
βs = 1.20
700𝛾𝑒
𝑠≤ − 2𝑑𝑒 AASHTO LRFD 5.7.3.4-1
𝛽𝑠 𝑓𝑠
s max = 23.5 cm
s= 15 cm s < s max OK
INFORME
REFORMULACIÓN DEL EXPEDIENTE TÉCNICO DE LA INVERSIÓN: FINAL
“MEJORAMIENTO DEL PUENTE VEHICULAR Y PEATONAL DE EXP-PP-001
PIQUECOCHA, DISTRITO DE VITIS, PROVINCIA DE YAUYOS – LIMA”
Rev: 01
Ec = 219,964 kg/cm2
Es = 2,100,000 kg/cm2
𝐸𝑠
n= 9 𝑛=
𝐸𝑐
As = 28.40 cm2/m Acero dispuesto
nAs = 255.60 cm2/m
𝑏𝑥 2
= 𝑛𝐴𝑠 (𝑑 − 𝑥)
2
x= 15.37 cm
𝑏𝑥 3
𝐼𝑐𝑟 = + 𝑛𝐴𝑆 (𝑑 − 𝑥)2
3
Icr = 666,064 cm4/m
0.6 fy = 2,520 kg/cm2
𝑛𝑀𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜 (𝑑 − 𝑥)
𝑓𝑠 =
𝐼𝑐𝑟
fs = 908 kg/cm2 fs < 0.6 fy OK
βs = 1.20
700𝛾𝑒
𝑠≤ − 2𝑑𝑒 AASHTO LRFD 5.7.3.4-1
𝛽𝑠 𝑓𝑠
s max = 69.0 cm
s= 20 cm s < s max OK
INFORME
REFORMULACIÓN DEL EXPEDIENTE TÉCNICO DE LA INVERSIÓN: FINAL
“MEJORAMIENTO DEL PUENTE VEHICULAR Y PEATONAL DE EXP-PP-001
PIQUECOCHA, DISTRITO DE VITIS, PROVINCIA DE YAUYOS – LIMA”
Rev: 01
Ec = 219,964 kg/cm2
Es = 2,100,000 kg/cm2
𝐸𝑠
n= 9 𝑛=
𝐸𝑐
As = 28.40 cm2/m Acero dispuesto
nAs = 255.60 cm2/m
𝑏𝑥 2
= 𝑛𝐴𝑠 (𝑑 − 𝑥)
2
x= 15.39 cm
𝑏𝑥 3
𝐼𝑐𝑟 = + 𝑛𝐴𝑆 (𝑑 − 𝑥)2
3
Icr = 669,811 cm4/m
0.6 fy = 2,520 kg/cm2
𝑛𝑀𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜 (𝑑 − 𝑥)
𝑓𝑠 =
𝐼𝑐𝑟
fs = 1,827 kg/cm2 fs < 0.6 fy OK
βs = 1.19
700𝛾𝑒
𝑠≤ − 2𝑑𝑒 AASHTO LRFD 5.7.3.4-1
𝛽𝑠 𝑓𝑠
s max = 30.0 cm
s= 20 cm s < s max OK
REFORMULACIÓN DEL EXPEDIENTE TÉCNICO DE LA INVERSIÓN: INFORME FINAL
“MEJORAMIENTO DEL PUENTE VEHICULAR Y PEATONAL DE EXP-PP-001
PIQUECOCHA, DISTRITO DE VITIS, PROVINCIA DE YAUYOS – LIMA”
Rev: 01
11.1 PANTALLA
𝑐𝑚2 𝑐𝑚2
El area de acero de temperatura debe cumplir: 2.33 ≤ As ≤ 12.7 AASHTO LRFD 5.10.8.2
𝑚 𝑚
As temp = 5.43 cm2/m
s max = 30 cm