CARACTERSTICAS
FAJA
FACTOR DE
SERVICIO
1.2
POTENCIA
(HP)
8
RPMSALIDA
260
DESARROLLO
H P =8 HP
KW
=5.968 KW
( 0.746
1 HP )
H P =5.968 KW
SELECCIONAMOS EL
ELECTRICOS WEG:
MOTOR
EN
TABLA
DE
MOTORES
m=
RELACIN DE TRANSMISIN:
1760
260
m=6.769
POTENCIA DE DISEO:
H P DISEO =H P CONSUMO x FS
H P DISEO =8 x 1.2
H P DISEO =9.6 HP
d MENOR
RELACIN DE
TRANSMISIN
DMAYOR , CALCULADO
5.4
5.6
5.8
6.0
6.2
6.4
6.6
6.8
7.0
7.4
6.769
6.769
6.769
6.769
6.769
6.769
6.769
6.769
6.769
6.769
36.5526
37.9064
39.2602
40.614
41.9678
43.3216
44.6754
46.0292
47.383
50.0906
m=
38
5.6
m=6.786
m=
38
1760
=
5.6 RPM SALIDA
RPM SALIDA =
1760
=259.358 RPM
6.786
D<C<3 ( D+d )
38 <C<130.8
Asumiendo:
C=
38+ 130.8
=84.4
2
L=2 C+1.65( D+ d)
SELECCIN DE LA FAJA:
SECCIN B
TABLA N7: ENTONCES SELECCIONAMOS B240
L=2 C+1.57 ( D+ d ) +
( Dd )2
4C
(385.6 )2
4C
0=8 C2689.392 C+1049.76
C=84.623
Dd 385.6
=
=0.383
C
84.623
INTERPOLANDO: TABLA 5
0.30
0.383
0.96
0.40
0.94
K =0.943
m = 6. 786
SECCIN B
H ADICIONAL=
0.04246 x 1760
100
H ADICIONAL=0.747
K L =1.22
POTENCIA TABULADA:
5.04
1760
H P , TABULADA
1800
5.45
H P , TABULADA =5.368
NMERO DE FAJAS:
N FAJAS=
H P , DISEO
HP /FAJA
N FAJAS=
9.6
7.035
N FAJAS=1.365
N FAJAS=2
CONCLUSIN:
C= 84.623
RPM = 259.358RPM
TOLERANCIA INSTALACIN = 1
TOLERANCIA TEMPLADO = 2