2 8555-9201-140 / 1010

TRANSLATION OF ORIGINAL MANUAL


Subject to modification!

The authors are always grateful for comments and suggestions for improving
the documentation. They can be addressed to:

GEA Mechanical Equipment


GEA Westfalia Separator Group GmbH
Werner-Habig-Str. 1, 59302 Oelde
Tel. +49 2522 77-0, Fax +49 2522 77-2488
ws.info@geagroup.com, www.westfalia-separator.com

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 3

For your safety


• Take special care when carrying out operations marked with this
symbol -
otherwise danger to life!

• Strictly adhere to instructions marked with this symbol.


This avoids damage to the separator and other equipment.

Note: • This symbol is not a safety precaution but rather a reference to infor-
mation which help to better understand the separator or plant compo-
nents and the processes.

GEA Mechanical Equipment / GEA Westfalia Separator


4 8555-9201-140 / 1010

1 Timer overview 7

1.1 Timerlist OSE 5-…-… ..............................................................................8


1.2 Timerlist OSE 10-…-… ............................................................................9
1.3 Timerlist OSE 20-…-… ..........................................................................10
1.4 Timerlist OSE 40-…-… ..........................................................................11
1.5 Timerlist OSE 80-…-… ..........................................................................12
1.6 Timerlist OSE 120-…-… ........................................................................13
1.7 Timer Description - T00 to T62 ............................................................14

2 Counter and Time Records 17

2.1 Default settings Counter - Time records ................................................18


2.2 Description Counter – Time Records .....................................................19
2.3 Settings Temperature – Ejection monitoring ..........................................20

3 Maintenance intervals and settings 21

3.1 Maintenance interval of the separator....................................................22


3.2 Maintenance interval of the Waterdetector (WMS-Sensor) ...................22
3.3 Waterdetector (WMS Sensor) check .....................................................23

4 Program logic 25

4.1 Program Logic - Symbols …- 0136 - … .................................................26


4.2 Program Logic - Symbols …- 0196 - … .................................................32
4.3 Program Logic - Symbols …- 91 - … .....................................................38

5 Trouble Shooting - Operating faults summary 45

5.1 Alarm overview .......................................................................................46


5.2 Alarm #00 - Know-How Protection .........................................................47
5.3 Alarm #01 - Motor Protection .................................................................48
5.4 Alarm #05 - TAL Oil Feed ......................................................................49
5.5 Alarm #06 - TAH Oil Feed ......................................................................50
5.6 Alarm #07 - Ejection Monitoring .............................................................51
5.7 Alarm #08 - LAHH Sludge Tank .............................................................52
5.8 Alarm #09 - Feed Pump Fault ................................................................53
5.9 Alarm #10 - Sludge Pump Fault .............................................................54
5.10 Alarm #11 Vibration Stage 1 ..................................................................55
5.11 Alarm #12 Vibration Stage 2 ..................................................................56
5.12 Alarm #15 - WMS system Fault .............................................................57
5.13 Alarm #18 - Bowl Monitoring ..................................................................58
5.14 Alarm #19 - Separator Motor Off ............................................................59
5.15 Alarm #22 - Excessive Running Time Of Sludge Pump ........................60
5.16 Alarm #23 - WMS Activated Too Often ..................................................61
5.17 Alarm #27 - Maintenance .......................................................................62
5.18 Alarm #28 - Warning Water content.......................................................63
5.19 Alarm #31 - TAL Oil Feed Warning ........................................................64
5.20 Alarm #32 - TAH Oil Feed Warning .......................................................65
5.21 Alarm #33 - Ejection Monitoring .............................................................66
5.22 Alarm #34 - Bowl Monitoring speed .......................................................67
5.23 Alarm #35 - Motor Start monitoring ........................................................68

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 5

5.24 Alarm #36 - Belt monitoring ...................................................................69


5.25 Alarm #37 - Max.- speed monitoring ......................................................70
5.26 Alarm #38 - Min.- speed monitoring .......................................................71
5.27 Alarm #39 - PT 1 Monitoring ..................................................................72
5.28 Alarm #40 - No Water Seal ....................................................................73
5.29 Alarm #41 - Min. Separating Time .........................................................74
5.30 Alarm #42 - SMS Sensor Fault ..............................................................75
5.31 Alarm #43 - SMS Sensor Active ............................................................76
5.32 Alarm #44 - PAL 1 Clean Oil Discharge.................................................77
5.33 Alarm #45 - PAH 1 Clean Oil Discharge ................................................78
5.34 Alarm #46 - EMERGENCY STOP .........................................................79
5.35 Alarm #48 - Water discharge overflow ...................................................80
5.36 Alarm #49 - MAINTENANCE required WMS Sensor .............................81

6 Alarm Simulation und Test 83

6.1 Alarms #01 - #10 ....................................................................................84


6.2 Alarms #11 - #20 ....................................................................................85
6.3 Alarms #21 - #30 ....................................................................................86
6.4 Alarms #31 - #40 ....................................................................................87
6.5 Alarms #41 - #50 ....................................................................................88

7 Ejection monitoring / Bowl monitoring 89

7.1 Graphic description Ejection- / Bowl monitoring - Motorcurrent:............90


7.2 Graphic description Ejection- / Bowl monitoring - Speed:......................91

8 Bowl volumes / Speed setpoints 93

8.1 Bowl-Volumes ........................................................................................94


8.2 Speed setpoints .....................................................................................94

GEA Mechanical Equipment / GEA Westfalia Separator


6 8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 7

1 Timer overview

1.1 Timerlist OSE 5-…-… ..............................................................................8


1.2 Timerlist OSE 10-…-… ............................................................................9
1.3 Timerlist OSE 20-…-… ..........................................................................10
1.4 Timerlist OSE 40-…-… ..........................................................................11
1.5 Timerlist OSE 80-…-… ..........................................................................12
1.6 Timerlist OSE 120-…-… ........................................................................13
1.7 Timer Description - T00 to T62 ............................................................14

GEA Mechanical Equipment / GEA Westfalia Separator


8 8555-9201-140 / 1010

1.1 Timerlist OSE 5-…-…


Control Unit E40 Separator-Type
Timer OSE 5
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec
T00 Partial ejection Partial ejection 1 1 1
T01 Displacement water Displacement 2 8 6 6 6
T02 Filling water Filling 2 8 5 5 5
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 1 1 1
T05 Speed recovery after Total ejection Speed rec.Total 8 8 8
T06 Closing water impulse Closingwater imp 0,08 0,08 0,08
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 240 240 240
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 8 8 8
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 30 10 10 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 5 5 5
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 300 300 300
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5 400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 1 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 15 40 25 25 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 25 0 20 0
T60 Start Impulse Start Impulse 6 6 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 1 1 0

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 9

1.2 Timerlist OSE 10-…-…


Control Unit E40 Separator-Type
Timer OSE 10
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec
T00 Partial ejection Partial ejection 1 1 1
T01 Displacement water Displacement 8 13 10 10 10
T02 Filling water Filling 3 11 8 8 8
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 1 1 1
T05 Speed recovery after Total ejection Speed rec.Total 8 8 8
T06 Closing water impulse Closingwater imp 0,08 0,08 0,08
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 240 240 240
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 8 8 8
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 30 10 10 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 5 5 5
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 300 300 300
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5 400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 1 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 25 50 35 35 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 20 0 18 0
T60 Start Impulse Start Impulse 10 10 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 1 1 0

GEA Mechanical Equipment / GEA Westfalia Separator


10 8555-9201-140 / 1010

1.3 Timerlist OSE 20-…-…


Control Unit E40 Separator-Type
Timer OSE 20
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec
T00 Partial ejection Partial ejection 1 1 1
T01 Displacement water Displacement 10 20 15 15 15
T02 Filling water Filling 4 17 12 12 12
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 1 1 1
T05 Speed recovery after Total ejection Speed rec.Total 10 10 10
T06 Closing water impulse Closingwater imp 0,1 0,1 0,1
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 240 240 240
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 10 10 10
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 35 15 15 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 5 5 5
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 600 600 600
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5 400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 1 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 40 80 60 60 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 9 0 7 0
T60 Start Impulse Start Impulse 20 20 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 1 1 0

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 11

1.4 Timerlist OSE 40-…-…


Control Unit E40 Separator-Type
Timer OSE 40
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec

T00 Partial ejection Partial ejection 2 2 2


T01 Displacement water Displacement 40 80 80 60 60
T02 Filling water Filling 30 50 40 40 40
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 2 2 2
T05 Speed recovery after Total ejection Speed rec.Total 15 15 15
T06 Closing water impulse Closingwater imp 0,1 0,1 0,1
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 480 480 480
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 15 15 15
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 40 20 20 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 5 5 5
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 900 900 900
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5 400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 2 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 50 150 130 130 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 9 0 3,5 0
T60 Start Impulse Start Impulse 80 80 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 3 3 0

GEA Mechanical Equipment / GEA Westfalia Separator


12 8555-9201-140 / 1010

1.5 Timerlist OSE 80-…-…


Control Unit E40 Separator-Type
Timer OSE 80
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec
T00 Partial ejection Partial ejection 3 3 3
T01 Displacement water Displacement 100 170 130 130 130
T02 Filling water Filling 40 150 100 100 100
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 3 3 3
T05 Speed recovery after Total ejection Speed rec.Total 20 20 20
T06 Closing water impulse Closingwater imp 0,1 0,1 0,1
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 600 600 600
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 20 20 20
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 50 30 30 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 5 5 5
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 1 200 1 200 1 200
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 2 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 200 290 260 260 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 9 0 5 0
T60 Start Impulse Start Impulse 160 160 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 3 3 0

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 13

1.6 Timerlist OSE 120-…-…


Control Unit E40 Separator-Type
Timer OSE 120
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec
T00 Partial ejection Partial ejection 5 5 5
T01 Displacement water Displacement 35 65 60 60 60
T02 Filling water Filling 10 40 30 30 30
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 5 5 5
T05 Speed recovery after Total ejection Speed rec.Total 20 20 20
T06 Closing water impulse Closingwater imp 1 1 1
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 600 600 600
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 20 20 20
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 50 30 30 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 20 20 20
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 0 0 0
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5 400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 2 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 40 140 110 110 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 9 0 2 0
T60 Start Impulse Start Impulse 60 60 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 3 3 0

GEA Mechanical Equipment / GEA Westfalia Separator


14 8555-9201-140 / 1010

1.7 Timer Description - T00 to T62


Active in
Timer Designation Action Description
-0136- -0196- -91-

Operating water valve V 3 The bowl sludge space is partial emptied by actu-
T00 Partial ejection
opens ating the operating water valve V 3. (Option) X X X

The bowl contents are displaced without loss by


Displacement water valve V 2 opening V 2. If preselected in the program, the
T01 Displacement water
opens setting will be taken from the automatic computing X X X
function during the sensor test.

The filling process creates the required water seal


inside the bowl by opening V 2. If preselected in
the program, the setting will be taken from the
T02 Filling water Filling water valve V 2 opens
automatic computing function during the sensor --- X X
test. Filling water is also active during WMS-
Sensor Check for HFO separators.

Oil feed valve V 1 closes.


After pressing start/stop, the timer is activated
T03 Waiting Clean oil discharge pressure is
before the displacement water function is initiated. X X X
reduced.

Operating water valve V 3 The bowl sludge space is emptied by actuating the
T04 Total ejection
opens operating water valve V 3. X X X

Speed recovery after Timer to compensate a speed drop occured during


T05
Total ejection total ejection. X X X

Closing water impul- Operating water valve V 3 Timer for safety water to keep the bowl closed
T06
se opens during separation. X X X

After timer is expired, product After timer is expired, the standard alarms like
T07 Alarm delay
feed valve V 1 closes. PAL1/PAH1, TAL/TAH, PAH2 ect. will be initiated. X X X

Waiting after Timer to stabilize the system after displacement


T08
displacement process. X X X

T09 Waiting after filling Timer to stabilize the system after filling process. --- X X

Start button of motor starter


Timer for monitoring operating speed after motor
T10 Separator starting activated and start-up of sepa-
start. X X X
rator motor.

T11 Alarm Bridging Alarms not activated. Timer to stabilize the process conditions! X X X

Waiting after 1. Timer to compensate a speed drop occured during


T12
ejection 1. ejection. X X X

Speed recovery after Timer to compensate a speed drop occured during


T13
partial ejection partial ejection. (Option) X X X

T14 Closing water interval Time interval between two closing water pulses. X X X

Circulation valve
T15
close
Circulation valve V 5 closes. Timer in which the circulation valve is closed! X --- ---

Circulation valve Circulation valve V 5 opens. Timer in which the circulation valve is opened!
T16
open WMS Sensor is activated. WMS Sensor Signal is checked. X --- ---

Time to prevent wrong indication for Water content


Water content Warning for Water content is
T17
bridging not active
Warning due to high amount of filling water. Active --- X ---
after separation start and after SMS-Mode.

Sludge tank alarm Alarm is activated when timer


T18
delay
Timer delay for sludge tank alarm. X X X
has elapsed. Start of ejection

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 15

Active in
Timer Designation Action Description
-0136- -0196- -91-
program.

Water impulse by Operating water valve V 3 Timer for closing the bowl after separator is on
T19
start opens operating speed. X X X
T20 Separation Product feed valve V 1 opens Timer for adjusting the separating time. X X X
In case of pressure drop (SMS Timer in which a system pressure drop is eva-
Min separation time PT 2) during T21 , triggering of luated as an alarm.
T21
with SMS alarm "Minimum separating X --- ---
time during SMS" Timer starts together with timer 20.

Alarm is activated when timer


has elapsed. The water dis-
Timer to trigger the alarm "High water content"
charge valve V 6 is open
only when the WMS sensor senses water during
T22 High water content while T 22 is activated, water
timer T 22. The timer is activated only when SMS X X ---
discharge valve V 6 is then
sensor PT 2 senses pressure.
closed and oil feed valve V 1
goes into circulation mode!
Feed pump is switched off Timer which switches off the feed pump after a
T23 Feed pump delay
after preset delay time of T23. delay time so that the heaters can cool off! X X X
Timer which switches off the sludge pump after a
Sludge pump delay After delay time of T 24,
T24
off sludge pump is switched off.
delay time to ensure that the sludge tank is emp- X X X
tied completely.
After delay time of T 25, an Timer which triggers the alarm "Vibration stage 1"
T25 Vibration 1 delay
ejection is initiated. only when the signal is activated for the time T 25! X X X
After delay time of T 26, the
safety water valve V 2 is
opened and the pneumatic Timer which triggers the alarm "Vibration stage 2"
T26 Vibration 2 delay
brake (option) actuated. The when the signal is activated for the time T 26! X X X
separator motor is shut down
immediately.
After delay time of T 27 within
Timer which triggers the alarm "Min separating
SMS low pressure time T 21 an alarm and ejec-
T27
delay tion is triggered in case of
time" when the signal is activated for the time T X --- ---
27!
pressure drop!
Monitoring of motor current or Timer which triggers the alarm "Ejection monitor-
speed during ejection phase. ing" when the motor current measured during this
T28 Ejection monitoring An ejection is initiated and the time does not exceed the preset offset value or X X X
product feed valve V 1 the speed measured during this time does not
switched to circulation mode. exceed the preset speed offset value.
Brake is actuated for time T Timer which automatically breaks down the sepa-
T29 Brake for separator
29. rator after an alarm "Vibration stage 2". X X X
T30 Free
T31 Free
Water discharge valve V 6
T32 WMS-Mode closes. Timer for process monitoring during separation! --- X ---
Circulation valve V 5 closes.
Water discharge valve V 6 Timer for sludge space monitoring. Only the SMS
T33 SMS-Mode closes. sensor PT 2 is activated. The sludge content of --- X ---
Circulation valve V 5 closes. the bowl is checked.
Circulation valve V 5 closes.
Circulation valve Water discharge valve V 6
T34
delay opens and closes after run-
Timer to flush the WMS sensor. --- X ---
down of the timer.
Circulation valve V 5 opens.
Water discharge valve V 6 Timer which triggers the alarm "Water seal bro-
Water seal broken closes. ken" only when the WMS sensor senses oil for the
T35
delay Triggering of alarm "water time T 35. The timer is activated only when SMS --- X ---
seal broken" after timer run- sensor PT 2 senses pressure.
down.

GEA Mechanical Equipment / GEA Westfalia Separator


16 8555-9201-140 / 1010

Active in
Timer Designation Action Description
-0136- -0196- -91-
Bowl is filled in intervals controlled by T37 with
Filling water valve V 2 opens filling water to check whether the sludge space is
T36 SMS pressure check in intervals until SMS sensor filled with sludge. If the sludge space is not full, X --- ---
PT 2 is activated. the SMS sensor PT 2 must respond to pressure. If
pressure is not increasing, an ejection is triggered.
Timer to set the interval between two filling water
Filling water valve V 2 closes.
T37 SMS Waiting
SMS sensor PT 2 is activated.
pulses for sludge space monitoring! See also X --- ---
SMS pressure check, above.
WMS sensor not activated.
SMS sensor PT 2 not acti- Timer to flush the sensing line after the first pro-
WMS Sensor flush-
T38
ing
vated. gram start so that it is clean and excessive filling --- X ---
Water discharge valve V 6 water is discharged!
opens.
Separator off after After delay T 39, the separa- Timer delay for separator motor stop. Function
T39
idle run tor motor is switched off. must be preselected in the program. X X X
Timer to operate the sludge pump until the sludge
T40 CU-Sludge pump On Sludge pump activated.
tank is completely emptied. X X X
T41 CU-Sludge pump Off Sludge pump not activated. Time interval between two sludge pump starts. X X X
T42 Free
T43 Free
Circulation valve V 5 closes. Timer in which the function of the SMS sensor PT
Water discharge valve V 6 2 is tested. If T44 is elapsed without SMS Sensor
T44 SMS-Sensor-Check
closes. PT 2 Signal, Alarm "SMS sensor failure during X X ---
SMS sensor PT 2 is activated. WMS-SMS check" is triggered.
T45 Free
T46 Free
When SMS Sensor PT 2 is Capacity and machine type-dependent timer
activated while T 47 is run- which determines the increse of water in the lube
ning, the water discharge oil during WMS mode. The pressure increase is
T47 Min.SMS Time
valve V 6 is opened for 3 evaluated as a function of T 47 over several --- X ---
seconds and Counter 5 successive cycles which are defined via counter 5
counts the PT 2 signal. "SMS time interval water content"
Timer to fill filling water into the bowl. This timer
runs before timer T61 and T62. Timer is required
T60 Start Impulse Filling water valve V 2 opens.
for the automatic calculation of timers 01 and 02. X X ---
Timer is protected.

Timer to set the interval between two sensor


T61 Sensor interval Filling water valve V 2 closes. impulses, T62. X X ---
Timer is protected.

Timer to fill filling water into the separator bowl.


This timer operates pulse-wise together with timer
T62 Sensor impulse Filling water valve V 2 opens. T61 after timer T60. Timer is required for the X X ---
automatic calculation of the timers 01 and 02.
Timer is protected.

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 17

2 Counter and Time Records

2.1 Default settings Counter - Time records ................................................18


2.2 Description Counter – Time Records .....................................................19
2.3 Settings Temperature – Ejection monitoring ..........................................20

GEA Mechanical Equipment / GEA Westfalia Separator


18
Control Unit

2.1
Separator-Type
Text Display Remarks OSE OSE OSE OSE OSE OSE
Full Text
(P = Setpoint; A = actual value) 5 10 20 40 80 120
Counter
C1 Flushing:
C01 Flushing Flushing counter 5 5 5 5 5 5
P: 5
A: 0
C2 Partial Ejection:
C02 Partial Ejection Partial ejection counter 5 5 5 5 5 5
(Option) P: 5
A: 0
C3 SMS Filling:
C03 SMS-Filling SMS fillng counter 5 5 5 5 5 5
P: 3
A: 0
C4 Sensor Check:
C04 Sensor-Check Sensor check counter 10 10 10 10 10 10
(Option) P: 10
A: 0

C5 Water content
Default settings Counter - Time records

C05 C5 SMS Time interval SMS Time interval counter


P: 5 5 5 5 5 5 5
(Option) Water cont water content Warning
A: 0

Time Record (TR… = Time Record …)


WMS-time
Time Record for WMS Time
TR1 WMS time during operation in last TR3 Max. in 24 h 60 min
TR1 40 60 150 150 240 300
(24h) hours. Act. in 24 h 0 min (Act. in = actuel 24h)
Last. in 24 h 0 min (Last in = previous 24h)

Sludgep.-time
Time Record for Max. in 24 h 30 min
TR2 TR2 Sludgep. time sludgepump time operation 30 30 30 40 50 60
in last TR3 (24h) hours. Act. in 24 h 0 min (Act. in = actuel 24h)
Last. in 24 h 0 min (Last in = previous 24h)

Time Record reset


TR3 Time Records Reset of all Time Records P: 24
TR3 reset after TR3 (24h) hours. A: 0 24 h 24 h 24 h 24 h 24 h 24 h
8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 19

2.2 Description Counter – Time Records

Active in:
No. Designation: Status: Description:
-0136- -0196- -91-

Counter (C… = Counter …)


Counter after how many ejections a
Flushing
C01 Counter for ejection doubled ejection for flushing the bowl X X X
Counter
will be initiated.
Counter after how many partial ejec-
C02 Counter for partial
Partial Ejection tions a doubled full ejection for flush- X X X
(Option) ejections.
ing the bowl will be initiated.
Counter for Fillingwa-
SMS Filling Counter for amount of fillingwater
C03 ter impulse after SMS --- X ---
Counter impulses after SMS Mode T33.
Mode T33.
C04 Sensor Check Counter for Sensor Counter after how many ejections the
X X ---
(Option) Counter check SMS Sensor Check will be initiated.
Counter for counting how many con-
SMS Time inter-
Counter for SMS Sen- secutive times SMS Sensor PT 2 was
C05 val counter for
sor signal during WMS activated shorter than T47. Gives --- X ---
(Option) water content
Mode. warning, if water content in oil is too
warning
high.

Time Records (TR… = Time Record …)


During operation, the time where the
WMS-Sensor is activated due to water
TR1 WMS-Time indication will be recorded. Time Re- X X ---
cords will be deleted when TR3 is
expired.
Time Records for recording the time
Sludgepump - where the sludge pump is in opera-
TR2 X X X
Time tion. Time Records will be deleted
when TR3 is expired.
When the presetted time is expired all
Time Records Time Records will be transferred to
TR3 X X X
reset the “Last in xh” values and values in
“Act. in xh” will be reset.

GEA Mechanical Equipment / GEA Westfalia Separator


20

2.3
Control Unit E40
Alarme Display Text Remarks Separator-Type
Full Text:
Control Unit:

Temperature- OSE
Monitoring DO MDO LO HFO
Separation Temperature 20 °C 40 °C 95 °C 98 °C
TAH OIL FEED
Temp. > max
TAH OIL FEED Alarm for an increase of the
Separation-Stop 30 °C 50 °C 105 °C 105 °C
Temp. > max oil temperature.
Alarm#06 press
HELP
TAL OIL FEED
Temp. < min
TAL OIL FEED Alarm for a decrease of the
Separation-Stop 10 °C 30 °C 85 °C 90 °C
Temp. < min oil temperature.
Alarm#05 press
HELP
Settings Temperature – Ejection monitoring

Ejection-
OSE 5 OSE 10 OSE 20 OSE 40 OSE 80 OSE 120
Monitoring

EJECTION
MONITORING:
Alarm for monitoring the
Eject. current < Value depending on the con-
Ejection monitoring ejection after separation or
Offset ditions of the power supply 0,5 A 0,5 A 0,5 A 3A 5A 8A
Eject. current < Offset after SMS ejection.
Separation-Stop system and the clutch shoes!
Current is monitored.
Alarm#07 press
HELP
EJECTION
MONITORING:
Alarm for monitoring the
Ejection monitoring Eject. speed < Off- Value depending on the con-
ejection after separation or
Eject. speed < Offset set ditions of the power supply 100 U/min 100 U/min 100 U/min 100 U/min 100 U/min 100 U/min
after SMS ejection.
(Option) Separation-Stop system and the clutch shoes!
Speed is monitored.
Alarm#33 press
HELP
8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 21

3 Maintenance intervals and settings

3.1 Maintenance interval of the separator....................................................22


3.2 Maintenance interval of the Waterdetector (WMS-Sensor) ...................22
3.3 Waterdetector (WMS Sensor) check .....................................................23

GEA Mechanical Equipment / GEA Westfalia Separator


22 8555-9201-140 / 1010

3.1 Maintenance interval of the separator

Maintenance-Interval:

Adjust operating hours

Set: 4000 h 0m 0s

Actual: 22 h 12 m 46 s

The factory setting for "Set" is a maintenance interval of 4000 hours as specified
in the separator instruction manual. Under "Actual", the operating hours of the
separator are counted.
When the pre-set number of operating hours is reached, a common alarm is ac-
tivated and a corresponding warning appears in the display. A common alarm
does not interrupt the separating program and must be acknowledged using the
ACK key.

Note:
Please take the maintenance interval setting from the instruction manual of the
separator used.

3.2 Maintenance interval of the Waterdetector (WMS-Sensor)

Maintenance-Interval WMS

Adjust operating hours

Set: 168 h 0m 0s

Actual: 22 h 12 m 46 s

Last water signal WMS:


211 h 48 m 21 s

The factory setting for "Set" is a maintenance interval of 168 hours (1 week).
Under "Actual", the operating hours of the WMS-Sensor water signal is counted.
In the case the “Actual” counter came up to the preset operating hours, a main-
tenance message will be activated with a corresponding hint that the WMS-
Sensor Check must be done! The message does not interrupt the separation
process and must be acknowledged with the „ACK“button after the WMS Sen-
sor Check. The acknowledgement resets the the “Actual” value.
Under “Last water signal WMS” the operating hours of the WMS Sensor since
the last water indication are counted. Only a water signal resets the operating
hours for “Last water signal WMS”.

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 23

3.3 Waterdetector (WMS Sensor) check

In the case the message „Maintenance WMS-Sensor“ occurs in the display, a manual check of the WMS-
Sensor function must be done. Please follow up the described steps!

Step

1 • Stop separation sequence by pushing touch key “Prog. OFF” on the control unit.

2 • Unscrew filling and displacement water


line (1).

3 • Remove the plug of the coupler socket (2).


• Assemble and connect filling and dis-
placement water feed line (1) with coupler
socket (2).

GEA Mechanical Equipment / GEA Westfalia Separator


24 8555-9201-140 / 1010

Step

4 • Turn over manual overide (A) of the filling


and displacement water feed valve (right
solenoid valve of the solenoid valve as-
sembly complete) for a maximum time of 5
seconds.

A:
Position 1: closed
Position 2: open

5 At the control unit


• Check signal input of the waterdetector (WMS-Sensor).
• Call up Digital-Input „DI 0.5“.
– DI 0.5 must change from status „0“ to „1“.

In the case that the signal did not change, • Take note to the chapter „Maintenance schedule“
• Remove waterdetector (WMS-Sensor), of the instruction manual of the used separator.
clean it and check function.

If the malfunction still persists,


• Waterdetector (WMS-Sensor) must be
exchanged.

6 • Check display „Maintenance-Interval WMS“ at control unit.


– The values for „Actual“ and „Last water signal WMS“ must be set back to 0.

7 • Remove filling and displacement water


line (1) from the coupler socket (2) and re-
connect it with the handle piece.

• Plug oft he coupler socket (2) must be


installed again.

8 Start of the separation process is possible by pushing the touch key „Prig. ON“ at the control unit.

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 25

4 Program logic

4.1 Program Logic - Symbols …- 0136 - … .................................................26


4.2 Program Logic - Symbols …- 0196 - … .................................................32
4.3 Program Logic - Symbols …- 91 - … .....................................................38

GEA Mechanical Equipment / GEA Westfalia Separator


26 8555-9201-140 / 1010

4.1 Program Logic - Symbols …- 0136 - …

Location: Symbol: Name of Component:

Water feed PCV1 Pressure reducing valve


V2 Filling-, Displacement water valve
V3 Operating water valve

Dirty oil feed V4 Preset valve


V1 Feed valve
TI Temperature indicator
TT Temperatur Transmitter

Clean oil discharge PI1 Pressure indicator


PT1 Pressure transmitter
V7 Clean oil discharge valve (option)

Dirty oil recirculation - -

Sensing line V5 Circulation valve


V6 Water discharge valve
WMS Water monitoring sensor
PT2 Presssure transmitter (SMS)
PI2 Pressure indicator (option)

Sludge tank LSHH Level switch high high


LSH Level switch high
LSL Level switch low

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 27

Diagram …- 0136 -… Chapter “A”

A A
Power supply
ON

Selftest
Control Unit

Motor Start button activated


Pump Start button activated
Separator Start (T10)
Water impuls by Start (T19)

Closing water program


Closing water interval (T14)
Closing water impuls (T06)
Process
options
activated
D

“Prog. ON” key activated

Start of
Sensor Check Sequence
Precondition:
Oil temperature > TSL setpoint
Oil temperature < TSH setpoint
LSHH not activated
Vibro II not activated
B

GEA Mechanical Equipment / GEA Westfalia Separator


28 8555-9201-140 / 1010

Diagram …- 0136 -… Chapter “B”

B
B
Start of
Separation sequence

Process
monitoring
activated
E
Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Closing water impulse (T06)


Separation (T20)
Bridging after ejection (T11)

SMS Sensor PT 2 activated


Circulation valve closes (T15)
Circulation valve opens (T16)

Stop of separation sequence


C

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 29

Diagram …- 0136 -… Chapter “C”

C
C
Stop of separation sequence

“Prog. OFF” key activated or


Motor OFF activated or
SMS filling Counter 3 elapsed or
Flushing Counter 1 elapsed

Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Separator
Ready for operation
A

GEA Mechanical Equipment / GEA Westfalia Separator


30 8555-9201-140 / 1010

Diagram …- 0136 -… Chapter “D”

D
D
Process
options
activated

Separator OFF Motor OFF


mode activated Button activated

Separator OFF mode Motor OFF


Separator OFF (T39) A

Alarm
Separator OFF activated
after (T39)
A

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 31

Diagram …- 0136 -… Chapter “E”

E
E
Process
monitoring
activated

PAL / PAH or LSHH activated LSL / LSH activated


TAL / TAH activated LSHH Sludge tank (T18) Start of Sludge pump
Alarm delay (T07) Total ejection (T04) Sludge pump delay (T24)
Sludge pump OFF
Option CU:
CU-Sludgepump On (T40)
CU-Sludgepump Off (T41)

CU = Compact Unit
Alarm
PAL / PAH
TAL / TAH
LAHH
A

GEA Mechanical Equipment / GEA Westfalia Separator


32 8555-9201-140 / 1010

4.2 Program Logic - Symbols …- 0196 - …

Location: Symbol: Name of Component:

Water feed PCV1 Pressure reducing valve


V2 Filling-, Displacement water valve
V3 Operating water valve

Dirty oil feed V4 Preset valve


V1 Feed valve
TI Temperature indicator
TT Temperatur Transmitter

Clean oil discharge PI1 Pressure indicator


PT1 Pressure transmitter
V7 Clean oil discharge valve (option)

Dirty oil recirculation - -

Sensing line V5 Circulation valve


V6 Water discharge valve
WMS Water monitoring sensor
PT2 Presssure transmitter (SMS)
PI2 Pressure indicator (option)

Sludge tank LSHH Level switch high high


LSH Level switch high
LSL Level switch low

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 33

Diagram …- 0196 -… Chapter “A”

A
A
Power supply
ON

Selftest
Control Unit

Motor Start button activated


Pump Start button activated
Separator Start (T10)
Water impuls by Start (T19)

Closing water program


Closing water interval (T14)
Closing water impuls (T06)

Process
optionens
activated
D

“Prog. ON” key activated

Start of
Sensor Check Sequence
Precondition:
Oil temperature > TSL setpoint
Oil temperature < TSH setpoint
LSHH not activated
Vibro II not activated
B

GEA Mechanical Equipment / GEA Westfalia Separator


34 8555-9201-140 / 1010

Diagram …- 0196 -… Chapter “B”

B
B
Start of
Separation sequence

Process
monitoring
activated
E
Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Separation program
Closing water impulse (T06)
Filling water (T02)
Waiting after filling (T09)
Separation (T20)
Sensor flushing (T38)
Bridging after ejection (T11)

SMS Sensor PT2 not activated


WMS Mode (T32)
SMS Mode (T33)
SMS pressure check (T36)
SMS waiting (T37)

Stop of separation sequence


C

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 35

Diagram …- 0196 -… Chapter “C”

C
C
Stop of separation sequence

“Prog. OFF” key activated or


Motor OFF activated or
SMS filling Counter 3 elapsed or
Flushing counter 1 elapsed
Sensor Check not okay

Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Separator
Ready for operation
A

GEA Mechanical Equipment / GEA Westfalia Separator


36 8555-9201-140 / 1010

Diagram …- 0196 -… Chapter “D”

D
D
Process
options
activated

Separator OFF Motor OFF


mode activated Button activated

Separator OFF mode Motor OFF


Separator OFF (T39) A

Alarm
Separator OFF activated
after (T39)
A

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 37

Diagram …- 0196 -… Chapter “E”

E
E
Process
monitoring
activated

PAL / PAH or LSHH activated LSL / LSH activated


TAL / TAH activated LSHH Sludge tank (T18) Start of Sludge pump
Alarm delay (T07) Total ejection (T04) Sludge pump delay (T24)
Sludge pump OFF
Option CU:
CU-Sludgepump On (T40)
CU-Sludgepump Off (T41)

CU = Compact Unit
Alarm
PAL / PAH
TAL / TAH
LAHH
A

GEA Mechanical Equipment / GEA Westfalia Separator


38 8555-9201-140 / 1010

4.3 Program Logic - Symbols …- 91 - …

Location: Symbol: Name of Component:

Water feed PCV1 Pressure reducing valve


V2 Filling-, Displacement water valve
V3 Operating water valve

Dirty oil feed V4 Preset valve


V1 Feed valve
TI Temperature indicator
TT Temperatur Transmitter

Clean oil discharge PI1 Pressure indicator


PT1 Pressure transmitter
V7 Clean oil discharge valve (option)

Dirty oil recirculation - -

Sensing line PT2 Presssure transmitter (PAH)


PI2 Pressure indicator (option)

Sludge tank LSHH Level switch high high


LSH Level switch high
LSL Level switch low

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 39

Diagram …- 91 -… Chapter “A”

A
A
Power supply
ON

Selftest
Control Unit

Motor Start button activated


Pump Start button activated
Separator Start (T10)
Water impuls by Start (T19)

Closing water program


Closing water interval (T14)
Closing water impuls (T06)

Process
optionens
activated
D

“Prog. ON” key activated

Start of
Separation Sequence
Precondition:
Oil temperature > TSL setpoint
Oil temperature < TSH setpoint
LSHH not activated
Vibro II not activated
B

GEA Mechanical Equipment / GEA Westfalia Separator


40 8555-9201-140 / 1010

Diagram …- 91 -… Chapter “B”

B
B
Start of
Separation sequence
Process
monitoring
activated
E
Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Separation program
Closing water impulse (T06)
Filling water (T02)
Waiting after filling (T09)
Separation (T20)
Bridging after ejection (T11)

SMS Sensor PT2 not activated


Separation (T20)

Stop of Separation sequence


C

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 41

Diagram …- 91 -… Chapter “C”

C
C
Stop of Separation sequence

“Prog. OFF” key activated or


Motor OFF activated or
Flushing Counter 1 elapsed

Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Separator
Ready for operation
A

GEA Mechanical Equipment / GEA Westfalia Separator


42 8555-9201-140 / 1010

Diagram …- 91 -… Chapter “D”

D
D
Process
options
activated

Separator OFF Motor OFF


mode activated Button activated

Separator OFF mode Motor OFF


Separator OFF (T39) A

Alarm
Separator OFF activated
after (T39)
A

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 43

Diagram …- 91 -… Chapter “E”

E
E
Process
monitoring
activated

PAL / PAH or LSHH activated LSL / LSH activated


TAL / TAH activated LSHH Sludge tank (T18) Start of Sludge pump
Alarm delay (T07) Total ejection (T04) Sludge pump delay (T24)
Sludge pump OFF
Option CU:
CU-Sludgepump On (T40)
CU-Sludgepump Off (T41)

Alarm
PAL / PAH CU = Compact Unit
TAL / TAH
LAHH
A

GEA Mechanical Equipment / GEA Westfalia Separator


44 8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 45

5 Trouble Shooting - Operating faults summary

5.1 Alarm overview .......................................................................................46


5.2 Alarm #00 - Know-How Protection .........................................................47
5.3 Alarm #01 - Motor Protection .................................................................48
5.4 Alarm #05 - TAL Oil Feed ......................................................................49
5.5 Alarm #06 - TAH Oil Feed ......................................................................50
5.6 Alarm #07 - Ejection Monitoring .............................................................51
5.7 Alarm #08 - LAHH Sludge Tank .............................................................52
5.8 Alarm #09 - Feed Pump Fault ................................................................53
5.9 Alarm #10 - Sludge Pump Fault .............................................................54
5.10 Alarm #11 Vibration Stage 1 ..................................................................55
5.11 Alarm #12 Vibration Stage 2 ..................................................................56
5.12 Alarm #15 - WMS system Fault .............................................................57
5.13 Alarm #18 - Bowl Monitoring ..................................................................58
5.14 Alarm #19 - Separator Motor Off ............................................................59
5.15 Alarm #22 - Excessive Running Time Of Sludge Pump ........................60
5.16 Alarm #23 - WMS Activated Too Often ..................................................61
5.17 Alarm #27 - Maintenance .......................................................................62
5.18 Alarm #28 - Warning Water content.......................................................63
5.19 Alarm #31 - TAL Oil Feed Warning ........................................................64
5.20 Alarm #32 - TAH Oil Feed Warning .......................................................65
5.21 Alarm #33 - Ejection Monitoring .............................................................66
5.22 Alarm #34 - Bowl Monitoring speed .......................................................67
5.23 Alarm #35 - Motor Start monitoring ........................................................68
5.24 Alarm #36 - Belt monitoring ...................................................................69
5.25 Alarm #37 - Max.- speed monitoring ......................................................70
5.26 Alarm #38 - Min.- speed monitoring .......................................................71
5.27 Alarm #39 - PT 1 Monitoring ..................................................................72
5.28 Alarm #40 - No Water Seal ....................................................................73
5.29 Alarm #41 - Min. Separating Time .........................................................74
5.30 Alarm #42 - SMS Sensor Fault ..............................................................75
5.31 Alarm #43 - SMS Sensor Active ............................................................76
5.32 Alarm #44 - PAL 1 Clean Oil Discharge.................................................77
5.33 Alarm #45 - PAH 1 Clean Oil Discharge ................................................78
5.34 Alarm #46 - EMERGENCY STOP .........................................................79
5.35 Alarm #48 - Water discharge overflow ...................................................80
5.36 Alarm #49 - MAINTENANCE required WMS Sensor .............................81

GEA Mechanical Equipment / GEA Westfalia Separator


46 8555-9201-140 / 1010

5.1 Alarm overview


Active in
Alarm No. Designation
-0136- -0196- -91-
#00 Know-How Protection X X X
#01 Motor Protection X X X
#05 TAL OIL Feed X X X
#06 TAH OIL Feed X X X
#07 Ejection Monitoring X X X
#08 LAHH Sludge Tank X X X
#09 Feed Pump Fault X X X
#10 Sludge Pump Fault X X X
#11 Vibration Stage 1 X X X
#12 Vibration Stage 2 X X X
#13 Fault Series Operation X --- ---
#15 WMS System Fault X X ---
#18 Bowl Monitoring X X X
#19 Separator Motor Off X X X
#22 Excessive Running Time Of Sludge Pump X X X
#23 WMS Activated Too Often X X ---
#27 Maintenance X X X
#28 Water content --- X ---
#31 TAL Oil Feed Warning X X X
#32 TAH Oil Feed Warning X X X
#33 Ejection Monitoring X X X
#34 Bowl Monitoring speed X X X
#35 Motor Start monitoring X X X
#36 Belt monitoring X X X
#37 Max.- speed monitoring X X X
#38 Min.- speed monitoring X X X
#39 PT 1 Monitoring X X X
#40 No Water Seal --- X ---
#41 Min. Separating Time X --- ---
#42 SMS Sensor Fault X X ---
#43 SMS Sensor Active X X ---
#44 PAL 1 Clean Oil Discharge X X X
#45 PAH 1 Clean Oil Discharge X X X
#46 EMERGENCY STOP X X X
#48 Water discharge overflow --- --- X
#49 MAINTENANCE required WMS Sensor X X ---

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 47

5.2 Alarm #00 - Know-How Protection


No. Time Status
2xxx hh:mm:ss IQ
KNOW-HOW PROTECTION No GEA-specific device. No warranty by operation!
Alarm#00 press HELP for info

Display shows Possible causes Remedy


• No GEA-specific device Use only GEA specific device!
• No warranty by operation ! Contact customer service!

Help text – Information on control

Step 1 Open HELP - menu

KNOW-HOW PROTECTION
No GEA-specific device
No warranty by operation!
Alarm#00 Please check:
Contact Westfalia
customer service !

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


48 8555-9201-140 / 1010

5.3 Alarm #01 - Motor Protection


No. Time Status
2xxx hh:mm:ss IQ
MOTOR PROTECTION Temp. > max temp. Motor shut off
Alarm#01 press HELP for info

Display shows Possible causes Remedy


• No motor protection switch signal Check functionality of motor protection
switch
• Brake not released Release brake
• Thermistor relay has triggered Check thermistor relay and cabling
• Operating water valve V2 open Check operating water valve V2
• Drive blocked Check drive
• Wrong number of clutch shoes Check number of clutch shoes
• Feed capacity too high Check capacity
• Motor ventilation not adequate Improve motor ventilation

• max temp. = see motor plate

Help text – Information on control

Step 1 Open HELP - menu

MOTOR PROTECTION
Alarm#01 Please check:
Motor protection function / Brake
Thermistor relay / Operating water
Valve V2 / No. of clutch shoes
Drive blocked / Feed capacity
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 49

5.4 Alarm #05 - TAL Oil Feed


No. Time Status
2xxx hh:mm:ss IQ
TAL OIL FEED Temp. < min Separation - Stop
Alarm#05 press HELP for info
x and yy = system data

Display shows Possible causes Remedy


Oil too cold before pre-heater • Check settling tank temperature
Feed capacity too high • Check feed capacity
Setting TAL has been set too high • Check setting TAL
Temperature of heating medium is too • Check temperature of heating me-
low dium
Temperature regulator defective • Check temperature regulator
E-pre-heater basic load or regulating • Check switching stages electrically
stage switched
Pre-heater dirty • Check pre-heater
PT100 sensor defective • Check sensor

Help text – Information on control

Step 1 Open HELP - menu

TAL OIL FEED


Alarm#05 Please check:
Settling tank temp. / Feed capacity
Setting TAL / Temp. of heating medium
Temp. regulator def./ Switching stages
elect. pre-heater / PT 100 sensor
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


50 8555-9201-140 / 1010

5.5 Alarm #06 - TAH Oil Feed


No. Time Status
2xxx hh:mm:ss IQ
TAH OIL FEED Temp. > max Separation - Stop
Alarm#06 press HELP for info

Display shows Possible causes Remedy


Oil too hot • Check regulating valve
Feed capacity too low • Check feed capacity
Setting TAH too low • Check setting TAH
E-pre-heater basic load or regulating • Check switching stages electrically
stages switched
Temperature regulator defective • Check temperature regulator
PT 100 sensor defective • Check PT 100 sensor

Help text – Information on control

Step 1 Open HELP - menu

TAH OIL FEED


Alarm#06 Please check:
Regulating valve / Feed capacity
Setting TAH / Switching stages electr.
Temp. regulator def./
PT 100 sensor
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 51

5.6 Alarm #07 - Ejection Monitoring


No. Time Status
2xxx hh:mm:ss IQ
EJECTION MONITORING Eject. current < Offset
Alarm#07 press HELP for info
x and yy = system data

Display shows Possible causes Remedy


Operating water valve V3 does not • Check function bowl hydraulics with
open valve V3
Connector on valve V3 loose • Check connector on V3
Offset setting for discharge current too • Check offset setting
high
Water quantity at V3 too low • Check water quantity
Setting of monitoring time for timer 28 • Check timer 28
is too short
Current evaluation defective • Check current converter electrically
Pre-strainer at V3 dirty • Check pre-strainer
Clutch shoes worn or oily • Check clutch shoes

Help text – Information on control

Step 1 Open HELP - menu

EJECTION MONITORING
Alarm#07 Please check:
Function of bowl / Hydraulics with V3
Connector valve V3 / Current offset setting/
Water quantity / TIMER 28
Current converter / Pre-strainer
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


52 8555-9201-140 / 1010

5.7 Alarm #08 - LAHH Sludge Tank


No. Time Status
2xxx hh:mm:ss IQ
LAHH SLUDGE TANK Sludge tank – full Separation - Stop
Alarm#08 press HELP for info

Display shows Possible causes Remedy


Sludge pump not functioning • Check sludge pump
Bowl is open • Check bowl hydraulics
Oil overflow due to excessive clean oil • Check valves in the clean oil line
discharge pressure and setting V7
Closing water pulse T06 too long • Check closing water pulse T06
Polyamide sealing ring defective • Check polyamide sealing ring
Sealing rings in the bowl defective • Check sealing rings
Level switch LSHH dirty or defective • Check level switch LSHH

Help text – Information on control

Step 1 Open HELP - menu

LAHH SLUDGE TANK


Alarm #08 Please check:
Sludge pump / Bowl hydraulics
Valves in the clean oil line
Setting V7 / Closing water pulse
Polyamide sealing ring / Switch LSHH
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 53

5.8 Alarm #09 - Feed Pump Fault


No. Time Status
2xxx hh:mm:ss IQ
FEED PUMP FAULT Motor protection Separation - Stop
Alarm#09 press HELP for info

Display shows Possible causes Remedy


Pump overloaded • Check protection switch current of
motor circuit breaker
Pump mechanically blocked • Check pump
Valves in the feed line closed • Check valves
Feed temperature • Check feed temperature
Filter in feed line dirty • Check filter
Electrical connections wrong • Check electrical connections and
cabling

Help text – Information on control

Step 1 Open HELP - menu

FEED PUMP FAULT


Alarm #09 Please check:
Protection switch / Current consumption/
Pump / Valves / Feed temperature / Filter
Electr. connections / Cabling
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


54 8555-9201-140 / 1010

5.9 Alarm #10 - Sludge Pump Fault


No. Time Status
2xxx hh:mm:ss IQ
SLUDGE PUMP FAULT Program - Stop
Alarm#10 press HELP for info

Display shows Possible causes Remedy


Pump overloaded • Check protection switch and current
of circuit breaker
Pump mechanically blocked • Check pump
Valves in the discharge line closed • Check valves
Pipe work dirty • Check pipe work
Electrical connections wrong • Check electrical connections and
cabling

Help text – Information on control

Step 1 Open HELP - menu

SLUDGE PUMP FAULT


Alarm #10 Please check:
Protection switch / Current consumption /
Pump / Valves / Pipe work
Electrical connection / Cabling
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 55

5.10 Alarm #11 Vibration Stage 1


No. Time Status
2xxx hh:mm:ss IQ
VIBRATION STAGE 1: Motor off after T25
Alarm#11 press HELP for info

Display shows Possible causes Remedy


Limit value 1 longer than T25 • Check T25
Uneven solid deposits in the bowl • Check solids holding space and
polyamide sealing ring
Vibrosensor has become detached • Check sensor fixing
Limit value 1 set to low • Check setting
Bowl not properly assembled or dam- • Open and clean bowl, assemble in
aged or wrong parts of other bowl accordance with operating instruc-
tions; use only parts with the same
series number
External vibrations • Check foundation fixing

Help text – Information on control

Step 1 Open HELP - menu

VIBRATION STAGE 1
Alarm#11 Please check:
TIMER 25 / Solids holding space
Polyamide sealing ring / Sensor
Fixing / Limit value 1 / Correct
bowl parts / Foundation fixing
Press ESC then ACK

or
Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


56 8555-9201-140 / 1010

5.11 Alarm #12 Vibration Stage 2


No. Time Status
2xxx hh:mm:ss IQ
VIBRATION STAGE 2: Separator – off
Alarm#12 press HELP for info

Display shows Possible causes Remedy


Setting of limit value 2 is too low • Check setting
Irregular solid deposits in the bowl • Check solids holding space and
polyamide sealing ring
Vibrosensor has become detached • Check sensor fixing
Bowl not properly assembled or dam- • Open and clean bowl, assemble in
aged or wrong parts of other bowl accordance with operating instruc-
tions; use only parts with the same
series number
External vibrations • Check foundation fixing

Help text – Information on control

Step 1 Open HELP - menu

VIBRATION STAGE 2
Alarm #12 Please check:
Limit value 2 / Solids holding space
Polyamide sealing ring / Sensor
Fixing / Correct bowl parts
Foundation fixing
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 57

5.12 Alarm #15 - WMS system Fault


No. Time Status
2xxx hh:mm:ss IQ
WMS SYSTEM FAULT Too much water Separation - Stop
Alarm#15 press HELP for info

Display shows Possible causes Remedy


Water content in oil feed too high • Check oil feed
Too much filling water setting of T02 • Check T02
too long
Filling water valve V2 leaking • Check filling water valve V2
Setting of timer T22 too short • Check setting In an emer-
ency,extend T22 during this phase

Help text – Information on control

Step 1 Open HELP - menu

WMS SYSTEM FAULT


Alarm#15 Please check:
Water content in oil feed
Filling water quantity / Setting T02
Valve V2 / Setting T22
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


58 8555-9201-140 / 1010

5.13 Alarm #18 - Bowl Monitoring


No. Time Status
2xxx hh:mm:ss IQ
BOWL MONITORING Current > Offset during TIMER 06
Alarm#18 press HELP for info

Display shows Possible causes Remedy


T06 closing water pulse too long, bowl • Check T06
has opened
Current offset bowl monitoring too low • Check current offset

Frequency of main power supply not • Check frequency of main power


stable supply
Water pressure for hydraulics during • Check water pressure with open
T06 too high, bowl has opened valve V3
Valve V3 is dirty, sticks, stays open for • Check valve V3
too long
New clutch shoes installed • Check current value
New belt installed • Check current value
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

BOWL MONITORING
Alarm#18 Please check:
TIMER T06 / Current offset
Frequency power supply
Water pressure for hydraulic
Function V3
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 59

5.14 Alarm #19 - Separator Motor Off


No. Time Status
2xxx hh:mm:ss IQ
SEP. MOTOR OFF Sep. in circulation T 39 expired M. off
Alarm#19 press HELP for info

Display shows Possible causes Remedy


Separator running in circulation T39 • Press program start before expiry of
has expired T39
Setting of T39 too short • Check T39
• In an emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

SEPARATOR MOTOR OFF


Alarm19# Please check:
TIMER 39 expired

Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


60 8555-9201-140 / 1010

5.15 Alarm #22 - Excessive Running Time Of Sludge Pump


No. Time Status
2xxx hh:mm:ss IQ
EXCESSIVE RUNNING TIME OF SLUDGE PUMP In TR3 h.
Alarm#22 press HELP for info

Display shows Possible causes Remedy


Setting of TR2 time recording too short • Check TR2 time recording
Bowl leakage • Check bowl function/hydraulics
Excessive water content in feed • Dewater product upstream of the
separator
Light oil overflow because clean oil • Check setting of clean oil discharge
discharge pressure too high pressure
Capacity of sludge pumps too low • Check pump function

Note:
TR2 = Time record of sludge pump operation, TR2 will be deleted when
TR3 has expired.
TR3 = Time counter factory setting 24 h

Help text – Information on control

Step 1 Open HELP - menu

EXCESSIVE RUN.TIME OF SLUDGE PUMP


Alarm#22 Please check:
TR2 time recording / Bowl function
Bowl leakage
Water content in Oil
Pump function
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 61

5.16 Alarm #23 - WMS Activated Too Often


No. Time Status
2xxx hh:mm:ss IQ
WMS ACTIVATED TOO OFTEN
Alarm#23 press HELP for info

Display shows Possible causes Remedy


Setting of TR1 time recording too short • Check TR1 time recording
Water content in oil too high • Dewater oil feed of the separator
Valve V2 not tight • Check V2

Note:
TR1 = Time record of WMS water sensor during HFO operation, TR1 will be
deleted when TR3 has expired.
TR3 = Time counter factory setting 24 h

Help text – Information on control

Step 1 Open HELP - menu

WMS ACTIVATED TOO OFTEN


Alarm#23 Please check:
TR1 time recording
Water content in Oil
Valve V2 is not tight

Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


62 8555-9201-140 / 1010

5.17 Alarm #27 - Maintenance


No. Time Status
2xxx hh:mm:ss IQ
MAINTENANCE required see manual
Alarm#27 press HELP for info

Display shows Possible causes Remedy


Operating hours have reached • Carry out maintenance according
– 4 000, manual
– 8 000, • Order spare parts from GEA West-
– 12 000, falia Separator Systems
– 16 000 • Order service from GEA Westfalia
or multiple hours. Separator Systems

Help text – Information on control

Step 1 Open HELP - menu

MAINTENANCE required
Alarm#27 Please check:
Operating hours have reached
4000; 8000; 12000; 16000 hours
or multiple / Carry out maintenance
according manual
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 63

5.18 Alarm #28 - Warning Water content


No. Time Status
2xxx hh:mm:ss IQ
WARNING WATER CONTENT
Alarm#28 press HELP for info

Display shows Possible causes Remedy


Water content in oil increased. • Dewater oil and check reason
T47 too long not consistent timer list • Check setting T47
Filling water valve V2 not tight • Check valve V2

Help text – Information on control

Step 1 Open HELP - menu

WARNING WATER CONTENT


Alarm#28 Please check:
Water content in Oil
Setting TIMER 47 and feed capacity
Valve V2 is not tight

Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


64 8555-9201-140 / 1010

5.19 Alarm #31 - TAL Oil Feed Warning


No. Time Status
2xxx hh:mm:ss IQ
TAL OIL FEED Temp. < min WARNING
Alarm#31 press HELP for info

Display shows Possible causes Remedy


Oil too cold before pre-heater • Check settling tank temperature
• (Settling tank applies to HFO only)
Feed capacity too high • Check feed capacity
Setting TAL has been set too high • Check setting TAL
Temperature of heating medium • Check temperature of heating me-
is too low dium
Temperature regulator defective • Check temperature regulator
E-pre-heater basic load or regulating • Check switching stages electrically
stage switched
Pre-heater dirty • Check pre-heater
PT100 sensor defective • Check sensor

Help text – Information on control

Step 1 Open HELP - menu

TAL OIL FEED


Alarm#31 Please check:
Settling tank temp. / Feed capacity
Setting TAL / Temp. of heating medium
Temp. regulator def. / Switching stages el.
pre-heater / PT 100 sensor
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 65

5.20 Alarm #32 - TAH Oil Feed Warning


No. Time Status
2xxx hh:mm:ss IQ
TAH OIL FEED Temp. > max WARNING
Alarm#32 press HELP for info

Display shows Possible causes Remedy


Oil too hot • Check regulating valve
Feed capacity too low • Check feed capacity
Setting TAH too low • Check setting TAH
E-pre-heater basic load or regulating • Check switching stages electrically
stage switched
Temperature regulator defective • Check temperature regulator
PT100 sensor defective • Check PT 100 sensor

Help text – Information on control

Step 1 Open HELP - menu

TAH OIL FEED


Alarm#32 Please check:
Regulating valve / Feed capacity
Setting TAH / Switching stages el.
Temp. regulator def.
PT 100 sensor
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


66 8555-9201-140 / 1010

5.21 Alarm #33 - Ejection Monitoring


No. Time Status
2xxx hh:mm:ss IQ
EJECTION MONITORING Eject. speed < Offset Sep. - Stop
Alarm#33 press HELP for info

Display shows Possible causes Remedy


Operating water valve V3 does not • Check function bowl hydraulics
open with valve V3
Connector on valve V3 loose • Check connector on V3
Seep offset ejection monitoring too • Check speed offset
high
Water quantity at V3 too low • Check water quantity
Setting of monitoring time for timer • Check timer 28
28 is too short
Speed pick-up sensor defective • Check speed pick -up sensor elec-
trically
Pre-strainer at V3 dirty • Check pre-strainer
Clutch shoes worn or oily • Check clutch shoes

Help text – Information on control

Step 1 Open HELP - menu

EJECTION MONITORING
Alarm#33 Please check:
Function of bowl / Hydraulics with V3
Connector valve V3 / Speed offset eject.
Water quantity / TIMER 28 / Speed pick- up
defective / Pre-strainer
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 67

5.22 Alarm #34 - Bowl Monitoring speed


No. Time Status
2xxx hh:mm:ss IQ
BOWL MONITORING Speed drop > Offset during T 06
Alarm#34 press HELP for info

Display shows Possible causes Remedy


T06 closing water pulse too long, bowl • Check T06
has opened
Water pressure for hydraulics during • Check water pressure with open
T06 too high, bowl has opened valve V3
Speed offset bowl monitoring too low • Check speed offset
Valve V3 is dirty, sticks, stays open for • Check valve V3
too long
Speed pick- up sensor defective • Check speed pick- up sensor electri-
cally
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

BOWL MONITORING
Alarm#34 Please check:
TIMER T06 / Water pressure
for hydraulic / Speed offset
bowl monitoring / Function V3
Speed pick- up defective
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


68 8555-9201-140 / 1010

5.23 Alarm #35 - Motor Start monitoring


No. Time Status
2xxx hh:mm:ss IQ
SEPARATOR-START monitoring during TIMER 10
Alarm#35 press HELP for info

Display shows Possible causes Remedy


T10 separator start time too short • Check T10

Brake not unfastened • Check brake

Clutch shoes worn or oily • Check clutch shoes

Drive belt worn or oily • Check drive belt

Speed setting for sensor operation- • Check speed setting


speed too high •
Speed pick- up sensor defective • Check speed pick- up sensor electri-
cally

Help text – Information on control

Step 1 Open HELP - menu

SEPARATOR- START
Alarm#35 Please check:
TIMER T10 / Brake unfastened / Clutch
shoes oily / Drive belt oily / Speed setting
of operation speed / Speed pick-up defective
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 69

5.24 Alarm #36 - Belt monitoring


No. Time Status
2xxx hh:mm:ss IQ
BELT MONITORING Drive belt broken during start up
Alarm#36 press HELP for info

Display shows Possible causes Remedy


Drive belt defect • Check drive belt
Motor defect • Check motor electrically
Clutch shoes worn or oily • Check clutch shoes
Speed pick- up sensor defective • Check speed pick- up sensor electri-
cally
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

BELT MONITORING
Alarm#36 Please check:
Drive belt / Motor defect electrically
Clutch shoes worn or oily
Speed pick- up defective
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


70 8555-9201-140 / 1010

5.25 Alarm #37 - Max.- speed monitoring


No. Time Status
2xxx hh:mm:ss IQ
MAX.- SPEED MONITORING during operation
Alarm#37 press HELP for info

Display shows Possible causes Remedy


Actual speed higher than permissible • Check speed
speed for operation
Speed setting for maximum speed too • Check maximum speed setting
low
Frequency unstable • Check frequency
Drive assembly (50 or 60 Hz) of sepa- • Check separator configuration for
rator does not fit to existing frequency frequency against existing frequency
at site at site
Speed pick- up sensor defective • Check speed pick –up sensor elec-
trically
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

MAX.- SPEED MONITORING


Alarm#37 Please check:
Speed in operation / Max.- Speed setting/
Frequency unstable / Sep. configuration
frequency opposite to frequency at site
Speed pick- up defective
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 71

5.26 Alarm #38 - Min.- speed monitoring


No. Time Status
2xxx hh:mm:ss IQ
MIN.- SPEED MONITORING during operation
Alarm#38 press HELP for info

Display shows Possible causes Remedy


Actual speed lower than permissible • Check speed
speed for operation
Speed setting for minimum speed too • Check minimum speed setting
high
Frequency unstable • Check frequency
Drive assembly (50 or 60 Hz) of sepa- • Check separator configuration for
rator does not fit to existing frequency frequency against existing frequency
at site at site
Speed pick- up sensor defective • Check speed pick –up sensor elec-
trically
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

MIN.- SPEED MONITORING


Alarm#38 Please check:
Speed in operation / Max.- Speed setting
Frequency unstable / Sep. configuration
frequency opposite to frequency at site
Speed pick- up defective
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


72 8555-9201-140 / 1010

5.27 Alarm #39 - PT 1 Monitoring


No. Time Status
2xxx hh:mm:ss IQ
PT 1 MONITORING clean oil discharge Separation – Stop
Alarm#39 press HELP for info

Display shows Possible causes Remedy


No pressure drop on PT 1 during dis- • Check switching function
charge
PT 1 is dirty, sticks or is defective • Clean and check PT 1
Setting of PAL 1 is too low • Check setting PAL 1
No ejection and ejection monitoring has • Check bowl hydraulics and ejection
not responded monitoring
Back pressure in system too high • Check discharge pressure
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

PT 1 MONITORING
Alarm#39 Please check:
Switching function PT 1
PT 1 dirty / Setpoint PAL 1
Bowl hydraulics / Ejection
monitoring / Discharge pressure
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 73

5.28 Alarm #40 - No Water Seal


No. Time Status
2xxx hh:mm:ss IQ
NO WATER SEAL during TIMER 35 Separation - Stop
Alarm#40 press HELP for info

Display shows Possible causes Remedy


Clean oil discharge pressure too • Check clean oil discharge pressure
high, valve V7 closed too far
Filling water valve V2 does not open • Check function V2
Filling water quantity too low, e.g. • Check filling water quantity
other consumers at same time
Filling water valve V2 or filters dirty • Check valve V2 and filters
Water pressure for hydraulics too • Check water pressure with open
high or T06 too long valve and T06
Shift of separating zone – oil • Check temperature and setting of
temperature too low TAL
Wrong sensing centripetal pump in- • Check parts in accordance with op-
stalled erating instruction
Pressure sensor PT 2 bridged or set • Check setting PT 2
to 0

Help text – Information on control

Step 1 Open HELP - menu

NO WATER SEAL
Alarm#40 Please check:
Clean oil discharge pressure
Function V2 / Filling water quantity
Valve V2 and filter / Water pressure
TIMER T06 / Setting TAL / Setting PT 2
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


74 8555-9201-140 / 1010

5.29 Alarm #41 - Min. Separating Time


No. Time Status
2xxx hh:mm:ss IQ
MIN. SEPARATING TIME < 10 min. Separation - Stop
Alarm#41 press HELP for info

Display shows Possible causes Remedy


Pressure sensor PT 2 not connected, • Check switching function of pressure
dirty or defective sensor PT 2
Alarm bridging time T11 too short • Check T11
Setting PT 2 too high • Check setting on pressure sensor
PT 2
Water or solids content in the bowl too • Pre-dewater oil and/or check solids
high content
To much filling water • Check filling water quantity
With HFO and parallel operation, • Remove screws from separating disk
screws in the separating disk installed
Filling water valve V2 not tight • Check filling water valve V2
Orifice in centripetal pump chamber • Check orifice
cover plugged

Help text – Information on control

Step 1 Open HELP - menu

MIN. SEPARATING TIME


Alarm#41 Please check:
Pressure sensor PT 2 / TIMER 11
Setting PAL 2 / Water content
Valve V2 / Screws in separating disk
with HFO operation
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 75

5.30 Alarm #42 - SMS Sensor Fault


No. Time Status
2xxx hh:mm:ss IQ
SMS SENSOR FAULT during SMS Check during TIMER 44
Alarm#42 press HELP for info

Display shows Possible causes Remedy


PT 2 no pressure signal • Check setting PT 2
Filling water valve V2 no function • Check function V2
T44 too short • Check T44
Sludge holding space blocking pres- • Clean bowl, check drill hole in cen-
sure sensor line to PT 2 tripetal pump chamber lid
Bowl not closed • Check bowl hydraulics
Insufficient water quantity during T44 • Check water quantity
• (Timer T60 – T62)
Pressure sensor PT 2 defective • Check pressure sensor
Wrong switching point on PT 2 • Check switching point
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

SMS SENSOR FAULT


Alarm#42 Please check:
Setting PAL 2 / Function V2
Timer 44 / Solids holding space
Orifice in centripetal pump chamber
cover / Bowl hydraulics / Function PT 2
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


76 8555-9201-140 / 1010

5.31 Alarm #43 - SMS Sensor Active


No. Time Status
2xxx hh:mm:ss IQ
SMS SENSOR ACTIVE in Idle run
Alarm#43 press HELP for info

Display shows Possible causes Remedy


Pressure sensor PT 2 activated during • Check pressure sensor PT 2
idle run conditions?
Filling water valve V2 leaking • Check V2
Product valve V1 does not close prop- • Check valve V1
erly
Non-return valve at V7 open, product • Close pure oil discharge valve V7
flows back into the bowl under no load

Help text – Information on control

Step 1 Open HELP - menu

SMS SENSOR ACTIVE IN IDLE RUN


Alarm#43 Please check:
Pressure sensor PT 2 / Valve V2 is
not tight/ Valve V1 closes not
properly / Oil flows back into the bowl
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 77

5.32 Alarm #44 - PAL 1 Clean Oil Discharge


No. Time Status
2xxx hh:mm:ss IQ
PAL 1 CLEAN OIL DISCHARGE Pressure < setting
Alarm#44 press HELP for info

Display shows Possible causes Remedy


Clean oil discharge valve V7 opened • Check valve setting V7
too wide
Feed capacity reduced • Check feed capacity
Setting PT 1 for PAL 1 too high • Check setting PT 1 for PAL 1
see also PAH 1 alarm
Water pressure for hydraulics too high • Check water pressure with opened
during T06, bowl has opened valve V3
Safety pulse T06 too long, bowl has • Check TIMER 06
opened
Feed pump failure • Check feed pump
FU speed too low • Check pump speed
Feed valve V1 in circulation position • Check compressed air and signal
output for solenoid valve on V1
Breakover to water side • Check quantity of filling water
Direction of rotation of pump incorrect • Check direction of rotation
Bowl gaskets not sealed • Check and where necessary replace
gaskets
T07 alarm delay too short • Check whether T07 expires before
pressure builds up
T11 alarm bridging too short • Check TIMER 11 alarm bridging
FU = Frequency transformer

Help text – Information on control

Step 1 Open HELP - menu

PAL 1 CLEAN OIL DISCHARGE


Alarm#44 Please check:
Valve setting V7 / Feed capacity
Setting PT1 for PAL / Water pressure for
opened valve V3 / TIMER 06 /T07 alarm
delay / Quantity of water / Bowl not sealed
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


78 8555-9201-140 / 1010

5.33 Alarm #45 - PAH 1 Clean Oil Discharge


No. Time Status
2xxx hh:mm:ss IQ
PAH 1 CLEAN OIL DISCHARGE Pressure > setting
Alarm#45 press HELP for info

Display shows Possible causes Remedy


Clean oil discharge valve V7 closed • Check valve setting V7
too far
Feed capacity too high • Check feed capacity
Setting PT1 for PAH1 too low • Check setting PT 1 for PAH 1

T07 alarm delay too short • Check T07


T11 alarm bridging too short • Check T11 alarm bridging
Oil temperature too low • Check temperature in oil feed

Help text – Information on control

Step 1 Open HELP - menu

PAH 1 CLEAN OIL DISCHAGE


Alarm#45 Please check:
Valve setting V7 / Feed capacity
Setting PT1 for PAH 1 / T07 alarm delay
T11 alarm bridging /
Temperature oil feed
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 79

5.34 Alarm #46 - EMERGENCY STOP


No. Time Status
2xxx hh:mm:ss IQ
EMERGENCY STOP
Alarm#46 press HELP for info

Display shows Possible causes Remedy


Emergency Stop Button was pushed. • Check reason for pushing Emer-
gency Stop button.

Help text – Information on control

Step 1 Open HELP - menu

EMERGENY STOP
Alarm#46 Please check:
Emergency Button
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


80 8555-9201-140 / 1010

5.35 Alarm #48 - Water discharge overflow


No. Time Status
2xxx hh:mm:ss IQ
WATER DISCHARGE overflow separation - Stop
Alarm#48 press HELP for info

Display shows Possible causes Remedy


Clean oil discharge pressure too • Check valve V7 in clean oil dis-
high charge line
Water content in feed too high • Check product feed
Quantity of filling water too low • Check function V2 and quantity of
Water seal broken filling water
Product temperature too low • Check product temperature
Regulating ring too large • Install next smaller regulating ring
Polyamide sealing ring defective • Check polyamide sealing ring
Sealing rings in the bowl defective • Check sealing rings
Pressure sensor PT2 defective • Check pressure sensor PT2

Help text – Information on control

Step 1 Open HELP - menu

WATER DISCHARGE
Alarm#48 Please check:
Clean oil valve V7 / Water cont. in Oil
Filling water quantity / oil
Temperature / Regulating ring
Polyamide ring / Press. sensor PT2
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 81

5.36 Alarm #49 - MAINTENANCE required WMS Sensor


No. Time Status
2xxx hh:mm:ss IQ
MAINTENANCE required WMS Sensor
Alarm#49 press HELP for info

Display shows Possible causes Remedy


Monitoring time of WMS Sensor • WMS Sensor Check must be done
has reached limit without water indi- according to manual.
cation

Help text – Information on control

Step 1 Open HELP - menu

MAINTENANCE required WMS Sensor


Alarm#49 Please Check:
Monitoring time of WMS Sensor
has reached limit without water indication
Carry out maintenance
according to manual

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


82 8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 83

6 Alarm Simulation und Test

6.1 Alarms #01 - #10 ....................................................................................84


6.2 Alarms #11 - #20 ....................................................................................85
6.3 Alarms #21 - #30 ....................................................................................86
6.4 Alarms #31 - #40 ....................................................................................87
6.5 Alarms #41 - #50 ....................................................................................88

GEA Mechanical Equipment / GEA Westfalia Separator


84 8555-9201-140 / 1010

6.1 Alarms #01 - #10

SIMULATION AND TESTS OF VARIOUS ALARMS


Alarm display Status Mechanical Electrical Action

MOTOR PROTECTION Control Not possible Disconnect PTC sensor • Separation


Temp. > max temp. active stop
Motor switched off • V1 in circula-
Alarm#01 tion
• Common alarm
Free

Alarm#02

Free

Alarm#03

Free

Alarm#04

TAL PRODUCT FEED Separation Not possible Set setting higher than the • Separation
Temp. < min current temperature stop
Separation - Stop • V1 in circula-
Alarm#05 tion
• Common alarm
TAH PRODUCT FEED Separation Not possible Set setting lower than the • Separation
Temp. > max current temperature stop
Separation - Stop • V1 in circula-
Alarm#06 press ENTER tion
• Common alarm
EJECTION MONITORING Ejection Close manual ball valve Disconnect cable head of V3 • Separation
Current< Offset which is in front of V3 or increase offset Ejection stop
Separation – Stop shortly before and during current during discharge • V1 in circula-
ALARM#07 discharge cycle T04. cycle T04. tion
• Common alarm
LAHH SLUDGE TANK Control Immerse or dampen Disconnect cable head of • Separation
Sludge tank - full Active sensor LSHH. LSHH Sensor stop
Separation - Stop • V1 in circula-
Alarm#08 tion
• Common alarm
FEED PUMP FAULT Control Not possible Trigger motor protection • Separation
Motor protection Active switch stop
Separation - Stop • V1 in circula-
Alarm#09 press ENTER tion
• Common alarm
SLUDGE PUMP FAULT Control Not possible Trigger motor protection • Separation
Program - stop Active switch stop
• V1 in circula-
Alarm#10 tion
• Common alarm

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 85

6.2 Alarms #11 - #20

SIMULATION AND TESTS OF VARIOUS ALARMS


Alarm display Status Mechanical Electrical Action

VIBRATION STAGE 1: Separation Not possible Disconnect contact • Separation


Motor off after T25 Stop
• V1 in circula-
Alarm#11 tion
• Ejection
• Motor off aft.
T26
• Common alarm

VIBRATION – STAGE 2: Control Not possible Disconnect contact • Separation
Separator - Off Active stop
• V1 in circula-
Alarm#12 tion
• Common alarm

FAULT SERIES Control Not possible MPI Leitungsanschluss an • Separation
OPERATION Line or Active der Steuerung abklemmen. stop
preselection not OK • V1 in circula-
Alarm#13 tion
• Common alarm

Free

Alarm#14

WMS SYSTEM FAULT Separation Open valve V2 to add Bridge WMS Sensor and set • Separation
Too much water water into bowl until pressure sensor PT2 switch- stop
Separation - Stop Timer 22 is elapsed. ing point to 0 or bridge. • V1 in circula-
Alarm#15 tion
• Common alarm
• Ejection
Free

Alarm#16

Free

Alarm#17

BOWL MONITORING Separation Not possible. Extend T06 during separa- • Common alarm
Current too high tion and shorten T14 to •
during TIMER 06 300sec.! Wait until T14 is
Alarm#18 elapsed and Alarm appears.

SEPARATOR MOTOR OFF Circulation Not possible. Set TIMER 39 to 10 seconds • Common alarm
Sep. in circulation and push program stop • Motor off
T 39 expired M. off button.
Alarm#19

Free

Alarm#20

GEA Mechanical Equipment / GEA Westfalia Separator


86 8555-9201-140 / 1010

6.3 Alarms #21 - #30

SIMULATION AND TESTS OF VARIOUS ALARMS


Alarm display Status Mechanical Electrical Action

Free

Alarm#21

EXCESSIVE RUNNING Control Set TR2 to 1 minute and Set TR2 to 1 minute • Common alarm
TIME OF SLUDGE PUMP Active immerse or dampen LSH Trigger testfunction with
In TR3 hours Sensor to start sludge magnet at testpoint of LSH
Alarm#22 pump until Alarm ap- sensor until Alarm appears.
pears.
WMS ACTIVATED Separation Set T22 to 300sec. and Set T22 to 300sec., TR1 to 1 • Common alarm
TOO OFTEN TR1 to 1 minute and minute and bridge WMS
open valve V2 to add sensor until Alarm appears.
Alarm#23 water into bowl until
Alarm appears.
Free •

Alarm#24

Free •

Alarm#25

Free •

Alarm#26

Maintenance Separation Not possible. Set value to actual value • Message in the
required see manual plus 1hour and wait 1hour. display

Alarm#27

WARNING Separation Set T17 to 1s and Set T17 to 1s and • Message in the
WATER CONTENT set counter 5 to 1 and set counter 5 to 1 and display
T47 to 60sec.than open bridge pressure sensor • V6 opens
Alarm#28 valve V2 for 10sec. to PSL2 or set optional PT2 to
add water into bowl until 0 and 1 in short intervals
warning appears. during T47 for minimum 2
times, so that warning ap-
pears.
Free

Alarm#29

Free

Alarm#30

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 87

6.4 Alarms #31 - #40

SIMULATION AND TESTS OF VARIOUS ALARMS


Alarm display Status Mechanical Electrical Action

Free

Alarm#31

Free

Alarm#32

EJECTION MONITORING Ejection Close manual ball valve Disconnect cable head of V3 • Separation
Eject. speed < Offset which is in front of V3 or increase offset Ejection stop
Separation – Stop shortly before and during speed during discharge • V1 in circula-
Alarm#33 discharge cycle T04. cycle T04. tion
• Common alarm
BOWL MONITORING Separation Not possible. Extend T06 during separa- • Common alarm
Speed drop too high tion and shorten T14 to •
during TIMER 06 300sec.! Wait until T14 is
Alarm#34 elapsed and Alarm appears.

SEPARATOR-START Separator Set Timer 10 to 10 sec. Set setting for min. speed • Motor off
monitoring Motor Start and press motor start higher than the normal • Message in the
during T10 button. operating speed. display
Alarm#35 • Common alarm

BELT MONITORING Separator Not possible. Disconnect speed pick-up • Motor off
Drive belt broken Motor Start sensor and press motor • Message in the
during start up start button. display
Alarm#36 • Common alarm

MAX.- SPEED Separator Not possible. Set setting for Max. Speed • Motor off
MONITORING Motor Start lower than normal operating • Message in the
during operation and Separa- speed, during start up or display
Alarm#37 tion during operation. • Common alarm

MIN.- SPEED Separator Not possible. Set setting for Min. Speed • Motor off
MONITORING Motor Start higher than normal operat- • Message in the
during operation and Separa- ing speed, display
Alarm#38 tion during start up or during • Common alarm
operation. •
PT 1 MONITORING Ejection Not possible. Set pressure sensor PT1 • Separation
clean oil discharge switching point to 0 while stop
Separation - Stop ejection sequence is run- • V1 in circula-
Alarm#39 ning. tion
• Common alarm

NO WATER SEAL Separation Reduce T34 and T35 to 5 Set pressure sensor PT2 to • Separation
during TIMER 35 sec. and close hand 0 and disconnect cable of stop
Separation - Stop valve before V2 during WMS sensor. • V1 in circula-
Alarm#40 T02. tion
• Common alarm
• Ejection

GEA Mechanical Equipment / GEA Westfalia Separator


88 8555-9201-140 / 1010

6.5 Alarms #41 - #50

SIMULATION AND TESTS OF VARIOUS ALARMS


Alarm display Status Mechanical Electrical Action

MIN. SEPARATING TIME Separation Not possible. Disconnect cable head on • Separation
< 10 Min pressure sensor PT2 during stop
Separation - Stop T21. • V1 in circula-
Alarm#41 tion
• Common alarm
• Ejection
SMS SENSOR FAULT Sensor Close hand valve at V2 Disconnect cable head on • Common alarm
during SMS Check Check while test is running. pressure sensor PT2 while • Ejection
during TIMER 44 test is running.
Alarm#42
PT2 SENSOR ACTIVE Circulation Open valve V2 until pres- Set pressure sensor PT2 to • Message in the
in Idle run sure increase on pres- 0 during idle run. display
sure sensor PT2 during • Common alarm
Alarm#43 idle run. • Ejection

PAL1 CLEAN OIL DISCHARGE Separation Open clean oil discharge Disconnect cable head on • Separation
Pressure < setting valve V7 pressure sensor PT1 stop
Separation - Stop • V1 in circula-
Alarm#44 tion
• Common alarm
• Ejection
PAH 1 CLEAN OIL DISCHARGE Separation Close clean oil discharge Set pressure sensor PT1 • Separation
Pressure > setting valve V7 switching point to a lower stop
Separation - Stop value than the current value. • V1 in circula-
Alarm#45 tion
• Common alarm
• Ejection
EMERGENCY STOP Control Not possible. Push emergeny button. • All electric
Button pushed Active components
are shut down
ALARM#46 like Motors,
Control Units
ect!
FREE

ALARM#47
WATER DISCHARGE: Separation Close clean oil discharge Set pressure sensor PT1 • Separation
Overflow valve V7. Set optional PAH1 switching point to 0 while stop
Separation - Stop (PT1) in clean oil discharge separation sequence is
to 10 bar.
• V1 in circula-
Alarm#48 running. tion
• Common alarm
• Ejection
MAINTENANCE required Circulation Not possible. Set value to actual value • Message in the
WMS Sensor plus 1minute and wait display
1minute. Add extra water to
Alarm#49 get WMS Signal if neces-
sary.
Free

Alarm#50

For a simulation, the function must be activated and must be valid for the product.

ATTENTION:
After the simulation, all changes must be reset to the initial conditions!!!!

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 89

7 Ejection monitoring / Bowl monitoring

7.1 Graphic description Ejection- / Bowl monitoring - Motorcurrent:............90


7.2 Graphic description Ejection- / Bowl monitoring - Speed:......................91

GEA Mechanical Equipment / GEA Westfalia Separator


90 8555-9201-140 / 1010

7.1 Graphic description Ejection- / Bowl monitoring - Motorcurrent:

1: separator motor start

2: feed valve V1 open: sepa-


ration

3: feed valve V1 closed for


ejection

4: operating water valve V3


open for T04: ejection

5: feed valve V1 open: sepa-


ration

1: separator motor start

2: feed valve V1 open: sepa-


ration

3: operating water valve V3


open for T06: safety water
impuls

4: operating water valve V3


closed: separation

5: feed valve V1 closed:


ejection

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 91

7.2 Graphic description Ejection- / Bowl monitoring - Speed:

0: separator motor start

1: feed valve V1 open: sepa-


ration

2: feed valve V1 closed for


ejection

3: operating water valve V3


open for T04: ejection

4: feed valve V1 open: sepa-


ration

0: separator motor start

1: feed valve V1 open: sepa-


ration

2: operating water valve V3


open for T06: safety water
impuls

3: operating water valve V3


closed: separation

GEA Mechanical Equipment / GEA Westfalia Separator


92 8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 93

8 Bowl volumes / Speed setpoints

8.1 Bowl-Volumes ........................................................................................94


8.2 Speed setpoints .....................................................................................94

GEA Mechanical Equipment / GEA Westfalia Separator


94 8555-9201-140 / 1010

8.1 Bowl-Volumes

Separator type

OSE 5 OSE 10 OSE 20 OSE 40 OSE 80 OSE 120


HFO LO HFO LO HFO LO HFO LO HFO LO HFO LO

3
Volumes in dm
Bowl volume 1,00 1,00 2,00 2,00 3,60 3,60 10,00 10,00 23,00 23,00 40,00 40,00
Sludgespace volume 0,50 0,50 0,90 0,90 1,60 1,60 4,00 4,00 10,00 10,00 14,60 14,60
Fillingwater volume 0,20 0,50 0,30 0,90 0,40 1,60 0,50 4,00 1,00 10,00 3,00 14,60
Displacementwater
volume
0,50 0,50 1,10 1,10 2,00 2,00 6,00 6,00 13,00 13,00 25,40 25,40

8.2 Speed setpoints

Separator type
OSE 5 / OSE 10 / OSE 20 OSE 40 OSE 80 OSE 120
Speed in U/min
Max. Speed 12 200 8 400 7 000 6 100
Min. Speed 11 500 7 800 6 300 5 400
Rated Speed 12 000 8 200 6 800 5 900

Speed -Offset
100 100 100 100
Ejection monitoring
Speed -Offset
100 100 100 100
Bowl monitoring

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 95

GEA Mechanical Equipment / GEA Westfalia Separator


96 8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


GEA Mechanical Equipment
GEA Westfalia Separator Group GmbH
Werner-Habig-Str. 1, 59302 Oelde
Tel. +49 2522 77-0, Fax +49 2522 77-2488
ws.info@geagroup.com, www.westfalia-separator.com
Settings and malfunctions

Designation Control system for OSE separators with self-cleaning bowl

Type E 40

No. 8555-9201-140

Edition 1010

GEA Mechanical Equipment / GEA Westfalia Separator


2 8555-9201-140 / 1010

TRANSLATION OF ORIGINAL MANUAL


Subject to modification!

The authors are always grateful for comments and suggestions for improving
the documentation. They can be addressed to:

GEA Mechanical Equipment


GEA Westfalia Separator Group GmbH
Werner-Habig-Str. 1, 59302 Oelde
Tel. +49 2522 77-0, Fax +49 2522 77-2488
ws.info@geagroup.com, www.westfalia-separator.com

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 3

For your safety


• Take special care when carrying out operations marked with this
symbol -
otherwise danger to life!

• Strictly adhere to instructions marked with this symbol.


This avoids damage to the separator and other equipment.

Note: • This symbol is not a safety precaution but rather a reference to infor-
mation which help to better understand the separator or plant compo-
nents and the processes.

GEA Mechanical Equipment / GEA Westfalia Separator


4 8555-9201-140 / 1010

1 Timer overview 7

1.1 Timerlist OSE 5-…-… ..............................................................................8


1.2 Timerlist OSE 10-…-… ............................................................................9
1.3 Timerlist OSE 20-…-… ..........................................................................10
1.4 Timerlist OSE 40-…-… ..........................................................................11
1.5 Timerlist OSE 80-…-… ..........................................................................12
1.6 Timerlist OSE 120-…-… ........................................................................13
1.7 Timer Description - T00 to T62 ............................................................14

2 Counter and Time Records 17

2.1 Default settings Counter - Time records ................................................18


2.2 Description Counter – Time Records .....................................................19
2.3 Settings Temperature – Ejection monitoring ..........................................20

3 Maintenance intervals and settings 21

3.1 Maintenance interval of the separator....................................................22


3.2 Maintenance interval of the Waterdetector (WMS-Sensor) ...................22
3.3 Waterdetector (WMS Sensor) check .....................................................23

4 Program logic 25

4.1 Program Logic - Symbols …- 0136 - … .................................................26


4.2 Program Logic - Symbols …- 0196 - … .................................................32
4.3 Program Logic - Symbols …- 91 - … .....................................................38

5 Trouble Shooting - Operating faults summary 45

5.1 Alarm overview .......................................................................................46


5.2 Alarm #00 - Know-How Protection .........................................................47
5.3 Alarm #01 - Motor Protection .................................................................48
5.4 Alarm #05 - TAL Oil Feed ......................................................................49
5.5 Alarm #06 - TAH Oil Feed ......................................................................50
5.6 Alarm #07 - Ejection Monitoring .............................................................51
5.7 Alarm #08 - LAHH Sludge Tank .............................................................52
5.8 Alarm #09 - Feed Pump Fault ................................................................53
5.9 Alarm #10 - Sludge Pump Fault .............................................................54
5.10 Alarm #11 Vibration Stage 1 ..................................................................55
5.11 Alarm #12 Vibration Stage 2 ..................................................................56
5.12 Alarm #15 - WMS system Fault .............................................................57
5.13 Alarm #18 - Bowl Monitoring ..................................................................58
5.14 Alarm #19 - Separator Motor Off ............................................................59
5.15 Alarm #22 - Excessive Running Time Of Sludge Pump ........................60
5.16 Alarm #23 - WMS Activated Too Often ..................................................61
5.17 Alarm #27 - Maintenance .......................................................................62
5.18 Alarm #28 - Warning Water content.......................................................63
5.19 Alarm #31 - TAL Oil Feed Warning ........................................................64
5.20 Alarm #32 - TAH Oil Feed Warning .......................................................65
5.21 Alarm #33 - Ejection Monitoring .............................................................66
5.22 Alarm #34 - Bowl Monitoring speed .......................................................67
5.23 Alarm #35 - Motor Start monitoring ........................................................68

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 5

5.24 Alarm #36 - Belt monitoring ...................................................................69


5.25 Alarm #37 - Max.- speed monitoring ......................................................70
5.26 Alarm #38 - Min.- speed monitoring .......................................................71
5.27 Alarm #39 - PT 1 Monitoring ..................................................................72
5.28 Alarm #40 - No Water Seal ....................................................................73
5.29 Alarm #41 - Min. Separating Time .........................................................74
5.30 Alarm #42 - SMS Sensor Fault ..............................................................75
5.31 Alarm #43 - SMS Sensor Active ............................................................76
5.32 Alarm #44 - PAL 1 Clean Oil Discharge.................................................77
5.33 Alarm #45 - PAH 1 Clean Oil Discharge ................................................78
5.34 Alarm #46 - EMERGENCY STOP .........................................................79
5.35 Alarm #48 - Water discharge overflow ...................................................80
5.36 Alarm #49 - MAINTENANCE required WMS Sensor .............................81

6 Alarm Simulation und Test 83

6.1 Alarms #01 - #10 ....................................................................................84


6.2 Alarms #11 - #20 ....................................................................................85
6.3 Alarms #21 - #30 ....................................................................................86
6.4 Alarms #31 - #40 ....................................................................................87
6.5 Alarms #41 - #50 ....................................................................................88

7 Ejection monitoring / Bowl monitoring 89

7.1 Graphic description Ejection- / Bowl monitoring - Motorcurrent:............90


7.2 Graphic description Ejection- / Bowl monitoring - Speed:......................91

8 Bowl volumes / Speed setpoints 93

8.1 Bowl-Volumes ........................................................................................94


8.2 Speed setpoints .....................................................................................94

GEA Mechanical Equipment / GEA Westfalia Separator


6 8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 7

1 Timer overview

1.1 Timerlist OSE 5-…-… ..............................................................................8


1.2 Timerlist OSE 10-…-… ............................................................................9
1.3 Timerlist OSE 20-…-… ..........................................................................10
1.4 Timerlist OSE 40-…-… ..........................................................................11
1.5 Timerlist OSE 80-…-… ..........................................................................12
1.6 Timerlist OSE 120-…-… ........................................................................13
1.7 Timer Description - T00 to T62 ............................................................14

GEA Mechanical Equipment / GEA Westfalia Separator


8 8555-9201-140 / 1010

1.1 Timerlist OSE 5-…-…


Control Unit E40 Separator-Type
Timer OSE 5
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec
T00 Partial ejection Partial ejection 1 1 1
T01 Displacement water Displacement 2 8 6 6 6
T02 Filling water Filling 2 8 5 5 5
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 1 1 1
T05 Speed recovery after Total ejection Speed rec.Total 8 8 8
T06 Closing water impulse Closingwater imp 0,08 0,08 0,08
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 240 240 240
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 8 8 8
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 30 10 10 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 5 5 5
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 300 300 300
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5 400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 1 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 15 40 25 25 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 25 0 20 0
T60 Start Impulse Start Impulse 6 6 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 1 1 0

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 9

1.2 Timerlist OSE 10-…-…


Control Unit E40 Separator-Type
Timer OSE 10
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec
T00 Partial ejection Partial ejection 1 1 1
T01 Displacement water Displacement 8 13 10 10 10
T02 Filling water Filling 3 11 8 8 8
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 1 1 1
T05 Speed recovery after Total ejection Speed rec.Total 8 8 8
T06 Closing water impulse Closingwater imp 0,08 0,08 0,08
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 240 240 240
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 8 8 8
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 30 10 10 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 5 5 5
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 300 300 300
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5 400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 1 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 25 50 35 35 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 20 0 18 0
T60 Start Impulse Start Impulse 10 10 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 1 1 0

GEA Mechanical Equipment / GEA Westfalia Separator


10 8555-9201-140 / 1010

1.3 Timerlist OSE 20-…-…


Control Unit E40 Separator-Type
Timer OSE 20
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec
T00 Partial ejection Partial ejection 1 1 1
T01 Displacement water Displacement 10 20 15 15 15
T02 Filling water Filling 4 17 12 12 12
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 1 1 1
T05 Speed recovery after Total ejection Speed rec.Total 10 10 10
T06 Closing water impulse Closingwater imp 0,1 0,1 0,1
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 240 240 240
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 10 10 10
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 35 15 15 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 5 5 5
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 600 600 600
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5 400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 1 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 40 80 60 60 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 9 0 7 0
T60 Start Impulse Start Impulse 20 20 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 1 1 0

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 11

1.4 Timerlist OSE 40-…-…


Control Unit E40 Separator-Type
Timer OSE 40
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec

T00 Partial ejection Partial ejection 2 2 2


T01 Displacement water Displacement 40 80 80 60 60
T02 Filling water Filling 30 50 40 40 40
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 2 2 2
T05 Speed recovery after Total ejection Speed rec.Total 15 15 15
T06 Closing water impulse Closingwater imp 0,1 0,1 0,1
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 480 480 480
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 15 15 15
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 40 20 20 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 5 5 5
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 900 900 900
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5 400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 2 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 50 150 130 130 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 9 0 3,5 0
T60 Start Impulse Start Impulse 80 80 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 3 3 0

GEA Mechanical Equipment / GEA Westfalia Separator


12 8555-9201-140 / 1010

1.5 Timerlist OSE 80-…-…


Control Unit E40 Separator-Type
Timer OSE 80
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec
T00 Partial ejection Partial ejection 3 3 3
T01 Displacement water Displacement 100 170 130 130 130
T02 Filling water Filling 40 150 100 100 100
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 3 3 3
T05 Speed recovery after Total ejection Speed rec.Total 20 20 20
T06 Closing water impulse Closingwater imp 0,1 0,1 0,1
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 600 600 600
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 20 20 20
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 50 30 30 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 5 5 5
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 1 200 1 200 1 200
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 2 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 200 290 260 260 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 9 0 5 0
T60 Start Impulse Start Impulse 160 160 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 3 3 0

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 13

1.6 Timerlist OSE 120-…-…


Control Unit E40 Separator-Type
Timer OSE 120
Timer

limits -0136- -0196- -91-


Full Text Display Text Min. / Max. HFO LO LO / (M)DO / HFO
(Option)
sec
T00 Partial ejection Partial ejection 5 5 5
T01 Displacement water Displacement 35 65 60 60 60
T02 Filling water Filling 10 40 30 30 30
T03 Waiting Waiting 5 5 5
T04 Total ejection Total ejection 5 5 5
T05 Speed recovery after Total ejection Speed rec.Total 20 20 20
T06 Closing water impulse Closingwater imp 1 1 1
T07 Alarm delay Alarm delay 5 15 10 10 10
T08 Waiting after displacement Wait aft.displac 5 5 5
T09 Waiting after filling Wait aft.filling 5 5 5
T10 Separator starting Separator Start 600 600 600
T11 Alarm bridging Alarm-bridging 15 40 30 30 30
T12 Waiting after 1. ejection Wait aft.1.Eject 10 10 10
T13 Speed recovery after partial ejection Speed rec.part. 20 20 20
T14 Closing water interval Closing Interval 300 1800 600 600 600
T15 Circulation valve close Circ.valve clos 60 0 0
T16 Circulation valve open Circ.valve open 5 0 0
T17 Water content bridging Water content bridg 0 600 0
T18 Sludge tank alarm delay LSHH-Sludgetank 10 10 10
T19 Water impulse by start Wat.Imp.by start 3 3 3
T20 Separation Separation 7 200 7 200 7 200
T21 Min separation time with SMS Min-Sep.-Time 600 0 0
T22 High water content High water cont. 2 50 30 30 0
T23 Feed pump delay Feedpump delay 300 300 300
T24 Sludge pump delay off Sludgep.delay 20 20 20
T25 Vibration 1 delay Vibro 1 180 180 180
T26 Vibration 2 delay Vibro 2 2 2 2
T27 SMS low pressure delay SMS PSL delay 5 15 10 0 0
T28 Ejection monitoring Ejection monitor 5 5 5
T29 Brake for separator Brake for Sep. 0 0 0
T30 Cooling Interval Cooling interval - - -
T31 Cooling water Cooling water - - -
T32 WMS-Mode WMS-Mode 0 5 400 0
T33 SMS-Mode SMS-Mode 0 120 0
T34 Circulation valve delay Circ.valve delay 1 20 0 10 0
T35 Water seal broken delay Water.Seal brok. 0 2 0 1 0
T36 SMS pressure check SMS Press.Check 0 2 0
T37 SMS Waiting SMS Waiting 0 3 0
T38 WMS Sensor flushing WMS Sensor flush 0 20 0
T39 Separator off after idle run Separator off 1 800 1 800 1 800
T40 CU-Sludgepump On CU-Sludgepu.On 20 20 20
T41 CU-Sludgepump Off CU-Sludgepu.Off 600 600 600
T42 Free Free - - -
T43 Free Free - - -
T44 SMS-Sensor-Check SMS-Sensor-Check 40 140 110 110 0
T45 Free Free - - -
T46 Free Free - - -
T47 Min.SMS Time Min.SMS Time 1 9 0 2 0
T60 Start Impulse Start Impulse 60 60 0
T61 Sensor interval Sensor interval 2 2 0
T62 Sensor impulse Sensor impulse 3 3 0

GEA Mechanical Equipment / GEA Westfalia Separator


14 8555-9201-140 / 1010

1.7 Timer Description - T00 to T62


Active in
Timer Designation Action Description
-0136- -0196- -91-

Operating water valve V 3 The bowl sludge space is partial emptied by actu-
T00 Partial ejection
opens ating the operating water valve V 3. (Option) X X X

The bowl contents are displaced without loss by


Displacement water valve V 2 opening V 2. If preselected in the program, the
T01 Displacement water
opens setting will be taken from the automatic computing X X X
function during the sensor test.

The filling process creates the required water seal


inside the bowl by opening V 2. If preselected in
the program, the setting will be taken from the
T02 Filling water Filling water valve V 2 opens
automatic computing function during the sensor --- X X
test. Filling water is also active during WMS-
Sensor Check for HFO separators.

Oil feed valve V 1 closes.


After pressing start/stop, the timer is activated
T03 Waiting Clean oil discharge pressure is
before the displacement water function is initiated. X X X
reduced.

Operating water valve V 3 The bowl sludge space is emptied by actuating the
T04 Total ejection
opens operating water valve V 3. X X X

Speed recovery after Timer to compensate a speed drop occured during


T05
Total ejection total ejection. X X X

Closing water impul- Operating water valve V 3 Timer for safety water to keep the bowl closed
T06
se opens during separation. X X X

After timer is expired, product After timer is expired, the standard alarms like
T07 Alarm delay
feed valve V 1 closes. PAL1/PAH1, TAL/TAH, PAH2 ect. will be initiated. X X X

Waiting after Timer to stabilize the system after displacement


T08
displacement process. X X X

T09 Waiting after filling Timer to stabilize the system after filling process. --- X X

Start button of motor starter


Timer for monitoring operating speed after motor
T10 Separator starting activated and start-up of sepa-
start. X X X
rator motor.

T11 Alarm Bridging Alarms not activated. Timer to stabilize the process conditions! X X X

Waiting after 1. Timer to compensate a speed drop occured during


T12
ejection 1. ejection. X X X

Speed recovery after Timer to compensate a speed drop occured during


T13
partial ejection partial ejection. (Option) X X X

T14 Closing water interval Time interval between two closing water pulses. X X X

Circulation valve
T15
close
Circulation valve V 5 closes. Timer in which the circulation valve is closed! X --- ---

Circulation valve Circulation valve V 5 opens. Timer in which the circulation valve is opened!
T16
open WMS Sensor is activated. WMS Sensor Signal is checked. X --- ---

Time to prevent wrong indication for Water content


Water content Warning for Water content is
T17
bridging not active
Warning due to high amount of filling water. Active --- X ---
after separation start and after SMS-Mode.

Sludge tank alarm Alarm is activated when timer


T18
delay
Timer delay for sludge tank alarm. X X X
has elapsed. Start of ejection

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 15

Active in
Timer Designation Action Description
-0136- -0196- -91-
program.

Water impulse by Operating water valve V 3 Timer for closing the bowl after separator is on
T19
start opens operating speed. X X X
T20 Separation Product feed valve V 1 opens Timer for adjusting the separating time. X X X
In case of pressure drop (SMS Timer in which a system pressure drop is eva-
Min separation time PT 2) during T21 , triggering of luated as an alarm.
T21
with SMS alarm "Minimum separating X --- ---
time during SMS" Timer starts together with timer 20.

Alarm is activated when timer


has elapsed. The water dis-
Timer to trigger the alarm "High water content"
charge valve V 6 is open
only when the WMS sensor senses water during
T22 High water content while T 22 is activated, water
timer T 22. The timer is activated only when SMS X X ---
discharge valve V 6 is then
sensor PT 2 senses pressure.
closed and oil feed valve V 1
goes into circulation mode!
Feed pump is switched off Timer which switches off the feed pump after a
T23 Feed pump delay
after preset delay time of T23. delay time so that the heaters can cool off! X X X
Timer which switches off the sludge pump after a
Sludge pump delay After delay time of T 24,
T24
off sludge pump is switched off.
delay time to ensure that the sludge tank is emp- X X X
tied completely.
After delay time of T 25, an Timer which triggers the alarm "Vibration stage 1"
T25 Vibration 1 delay
ejection is initiated. only when the signal is activated for the time T 25! X X X
After delay time of T 26, the
safety water valve V 2 is
opened and the pneumatic Timer which triggers the alarm "Vibration stage 2"
T26 Vibration 2 delay
brake (option) actuated. The when the signal is activated for the time T 26! X X X
separator motor is shut down
immediately.
After delay time of T 27 within
Timer which triggers the alarm "Min separating
SMS low pressure time T 21 an alarm and ejec-
T27
delay tion is triggered in case of
time" when the signal is activated for the time T X --- ---
27!
pressure drop!
Monitoring of motor current or Timer which triggers the alarm "Ejection monitor-
speed during ejection phase. ing" when the motor current measured during this
T28 Ejection monitoring An ejection is initiated and the time does not exceed the preset offset value or X X X
product feed valve V 1 the speed measured during this time does not
switched to circulation mode. exceed the preset speed offset value.
Brake is actuated for time T Timer which automatically breaks down the sepa-
T29 Brake for separator
29. rator after an alarm "Vibration stage 2". X X X
T30 Free
T31 Free
Water discharge valve V 6
T32 WMS-Mode closes. Timer for process monitoring during separation! --- X ---
Circulation valve V 5 closes.
Water discharge valve V 6 Timer for sludge space monitoring. Only the SMS
T33 SMS-Mode closes. sensor PT 2 is activated. The sludge content of --- X ---
Circulation valve V 5 closes. the bowl is checked.
Circulation valve V 5 closes.
Circulation valve Water discharge valve V 6
T34
delay opens and closes after run-
Timer to flush the WMS sensor. --- X ---
down of the timer.
Circulation valve V 5 opens.
Water discharge valve V 6 Timer which triggers the alarm "Water seal bro-
Water seal broken closes. ken" only when the WMS sensor senses oil for the
T35
delay Triggering of alarm "water time T 35. The timer is activated only when SMS --- X ---
seal broken" after timer run- sensor PT 2 senses pressure.
down.

GEA Mechanical Equipment / GEA Westfalia Separator


16 8555-9201-140 / 1010

Active in
Timer Designation Action Description
-0136- -0196- -91-
Bowl is filled in intervals controlled by T37 with
Filling water valve V 2 opens filling water to check whether the sludge space is
T36 SMS pressure check in intervals until SMS sensor filled with sludge. If the sludge space is not full, X --- ---
PT 2 is activated. the SMS sensor PT 2 must respond to pressure. If
pressure is not increasing, an ejection is triggered.
Timer to set the interval between two filling water
Filling water valve V 2 closes.
T37 SMS Waiting
SMS sensor PT 2 is activated.
pulses for sludge space monitoring! See also X --- ---
SMS pressure check, above.
WMS sensor not activated.
SMS sensor PT 2 not acti- Timer to flush the sensing line after the first pro-
WMS Sensor flush-
T38
ing
vated. gram start so that it is clean and excessive filling --- X ---
Water discharge valve V 6 water is discharged!
opens.
Separator off after After delay T 39, the separa- Timer delay for separator motor stop. Function
T39
idle run tor motor is switched off. must be preselected in the program. X X X
Timer to operate the sludge pump until the sludge
T40 CU-Sludge pump On Sludge pump activated.
tank is completely emptied. X X X
T41 CU-Sludge pump Off Sludge pump not activated. Time interval between two sludge pump starts. X X X
T42 Free
T43 Free
Circulation valve V 5 closes. Timer in which the function of the SMS sensor PT
Water discharge valve V 6 2 is tested. If T44 is elapsed without SMS Sensor
T44 SMS-Sensor-Check
closes. PT 2 Signal, Alarm "SMS sensor failure during X X ---
SMS sensor PT 2 is activated. WMS-SMS check" is triggered.
T45 Free
T46 Free
When SMS Sensor PT 2 is Capacity and machine type-dependent timer
activated while T 47 is run- which determines the increse of water in the lube
ning, the water discharge oil during WMS mode. The pressure increase is
T47 Min.SMS Time
valve V 6 is opened for 3 evaluated as a function of T 47 over several --- X ---
seconds and Counter 5 successive cycles which are defined via counter 5
counts the PT 2 signal. "SMS time interval water content"
Timer to fill filling water into the bowl. This timer
runs before timer T61 and T62. Timer is required
T60 Start Impulse Filling water valve V 2 opens.
for the automatic calculation of timers 01 and 02. X X ---
Timer is protected.

Timer to set the interval between two sensor


T61 Sensor interval Filling water valve V 2 closes. impulses, T62. X X ---
Timer is protected.

Timer to fill filling water into the separator bowl.


This timer operates pulse-wise together with timer
T62 Sensor impulse Filling water valve V 2 opens. T61 after timer T60. Timer is required for the X X ---
automatic calculation of the timers 01 and 02.
Timer is protected.

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 17

2 Counter and Time Records

2.1 Default settings Counter - Time records ................................................18


2.2 Description Counter – Time Records .....................................................19
2.3 Settings Temperature – Ejection monitoring ..........................................20

GEA Mechanical Equipment / GEA Westfalia Separator


18
Control Unit

2.1
Separator-Type
Text Display Remarks OSE OSE OSE OSE OSE OSE
Full Text
(P = Setpoint; A = actual value) 5 10 20 40 80 120
Counter
C1 Flushing:
C01 Flushing Flushing counter 5 5 5 5 5 5
P: 5
A: 0
C2 Partial Ejection:
C02 Partial Ejection Partial ejection counter 5 5 5 5 5 5
(Option) P: 5
A: 0
C3 SMS Filling:
C03 SMS-Filling SMS fillng counter 5 5 5 5 5 5
P: 3
A: 0
C4 Sensor Check:
C04 Sensor-Check Sensor check counter 10 10 10 10 10 10
(Option) P: 10
A: 0

C5 Water content
Default settings Counter - Time records

C05 C5 SMS Time interval SMS Time interval counter


P: 5 5 5 5 5 5 5
(Option) Water cont water content Warning
A: 0

Time Record (TR… = Time Record …)


WMS-time
Time Record for WMS Time
TR1 WMS time during operation in last TR3 Max. in 24 h 60 min
TR1 40 60 150 150 240 300
(24h) hours. Act. in 24 h 0 min (Act. in = actuel 24h)
Last. in 24 h 0 min (Last in = previous 24h)

Sludgep.-time
Time Record for Max. in 24 h 30 min
TR2 TR2 Sludgep. time sludgepump time operation 30 30 30 40 50 60
in last TR3 (24h) hours. Act. in 24 h 0 min (Act. in = actuel 24h)
Last. in 24 h 0 min (Last in = previous 24h)

Time Record reset


TR3 Time Records Reset of all Time Records P: 24
TR3 reset after TR3 (24h) hours. A: 0 24 h 24 h 24 h 24 h 24 h 24 h
8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 19

2.2 Description Counter – Time Records

Active in:
No. Designation: Status: Description:
-0136- -0196- -91-

Counter (C… = Counter …)


Counter after how many ejections a
Flushing
C01 Counter for ejection doubled ejection for flushing the bowl X X X
Counter
will be initiated.
Counter after how many partial ejec-
C02 Counter for partial
Partial Ejection tions a doubled full ejection for flush- X X X
(Option) ejections.
ing the bowl will be initiated.
Counter for Fillingwa-
SMS Filling Counter for amount of fillingwater
C03 ter impulse after SMS --- X ---
Counter impulses after SMS Mode T33.
Mode T33.
C04 Sensor Check Counter for Sensor Counter after how many ejections the
X X ---
(Option) Counter check SMS Sensor Check will be initiated.
Counter for counting how many con-
SMS Time inter-
Counter for SMS Sen- secutive times SMS Sensor PT 2 was
C05 val counter for
sor signal during WMS activated shorter than T47. Gives --- X ---
(Option) water content
Mode. warning, if water content in oil is too
warning
high.

Time Records (TR… = Time Record …)


During operation, the time where the
WMS-Sensor is activated due to water
TR1 WMS-Time indication will be recorded. Time Re- X X ---
cords will be deleted when TR3 is
expired.
Time Records for recording the time
Sludgepump - where the sludge pump is in opera-
TR2 X X X
Time tion. Time Records will be deleted
when TR3 is expired.
When the presetted time is expired all
Time Records Time Records will be transferred to
TR3 X X X
reset the “Last in xh” values and values in
“Act. in xh” will be reset.

GEA Mechanical Equipment / GEA Westfalia Separator


20

2.3
Control Unit E40
Alarme Display Text Remarks Separator-Type
Full Text:
Control Unit:

Temperature- OSE
Monitoring DO MDO LO HFO
Separation Temperature 20 °C 40 °C 95 °C 98 °C
TAH OIL FEED
Temp. > max
TAH OIL FEED Alarm for an increase of the
Separation-Stop 30 °C 50 °C 105 °C 105 °C
Temp. > max oil temperature.
Alarm#06 press
HELP
TAL OIL FEED
Temp. < min
TAL OIL FEED Alarm for a decrease of the
Separation-Stop 10 °C 30 °C 85 °C 90 °C
Temp. < min oil temperature.
Alarm#05 press
HELP
Settings Temperature – Ejection monitoring

Ejection-
OSE 5 OSE 10 OSE 20 OSE 40 OSE 80 OSE 120
Monitoring

EJECTION
MONITORING:
Alarm for monitoring the
Eject. current < Value depending on the con-
Ejection monitoring ejection after separation or
Offset ditions of the power supply 0,5 A 0,5 A 0,5 A 3A 5A 8A
Eject. current < Offset after SMS ejection.
Separation-Stop system and the clutch shoes!
Current is monitored.
Alarm#07 press
HELP
EJECTION
MONITORING:
Alarm for monitoring the
Ejection monitoring Eject. speed < Off- Value depending on the con-
ejection after separation or
Eject. speed < Offset set ditions of the power supply 100 U/min 100 U/min 100 U/min 100 U/min 100 U/min 100 U/min
after SMS ejection.
(Option) Separation-Stop system and the clutch shoes!
Speed is monitored.
Alarm#33 press
HELP
8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 21

3 Maintenance intervals and settings

3.1 Maintenance interval of the separator....................................................22


3.2 Maintenance interval of the Waterdetector (WMS-Sensor) ...................22
3.3 Waterdetector (WMS Sensor) check .....................................................23

GEA Mechanical Equipment / GEA Westfalia Separator


22 8555-9201-140 / 1010

3.1 Maintenance interval of the separator

Maintenance-Interval:

Adjust operating hours

Set: 4000 h 0m 0s

Actual: 22 h 12 m 46 s

The factory setting for "Set" is a maintenance interval of 4000 hours as specified
in the separator instruction manual. Under "Actual", the operating hours of the
separator are counted.
When the pre-set number of operating hours is reached, a common alarm is ac-
tivated and a corresponding warning appears in the display. A common alarm
does not interrupt the separating program and must be acknowledged using the
ACK key.

Note:
Please take the maintenance interval setting from the instruction manual of the
separator used.

3.2 Maintenance interval of the Waterdetector (WMS-Sensor)

Maintenance-Interval WMS

Adjust operating hours

Set: 168 h 0m 0s

Actual: 22 h 12 m 46 s

Last water signal WMS:


211 h 48 m 21 s

The factory setting for "Set" is a maintenance interval of 168 hours (1 week).
Under "Actual", the operating hours of the WMS-Sensor water signal is counted.
In the case the “Actual” counter came up to the preset operating hours, a main-
tenance message will be activated with a corresponding hint that the WMS-
Sensor Check must be done! The message does not interrupt the separation
process and must be acknowledged with the „ACK“button after the WMS Sen-
sor Check. The acknowledgement resets the the “Actual” value.
Under “Last water signal WMS” the operating hours of the WMS Sensor since
the last water indication are counted. Only a water signal resets the operating
hours for “Last water signal WMS”.

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 23

3.3 Waterdetector (WMS Sensor) check

In the case the message „Maintenance WMS-Sensor“ occurs in the display, a manual check of the WMS-
Sensor function must be done. Please follow up the described steps!

Step

1 • Stop separation sequence by pushing touch key “Prog. OFF” on the control unit.

2 • Unscrew filling and displacement water


line (1).

3 • Remove the plug of the coupler socket (2).


• Assemble and connect filling and dis-
placement water feed line (1) with coupler
socket (2).

GEA Mechanical Equipment / GEA Westfalia Separator


24 8555-9201-140 / 1010

Step

4 • Turn over manual overide (A) of the filling


and displacement water feed valve (right
solenoid valve of the solenoid valve as-
sembly complete) for a maximum time of 5
seconds.

A:
Position 1: closed
Position 2: open

5 At the control unit


• Check signal input of the waterdetector (WMS-Sensor).
• Call up Digital-Input „DI 0.5“.
– DI 0.5 must change from status „0“ to „1“.

In the case that the signal did not change, • Take note to the chapter „Maintenance schedule“
• Remove waterdetector (WMS-Sensor), of the instruction manual of the used separator.
clean it and check function.

If the malfunction still persists,


• Waterdetector (WMS-Sensor) must be
exchanged.

6 • Check display „Maintenance-Interval WMS“ at control unit.


– The values for „Actual“ and „Last water signal WMS“ must be set back to 0.

7 • Remove filling and displacement water


line (1) from the coupler socket (2) and re-
connect it with the handle piece.

• Plug oft he coupler socket (2) must be


installed again.

8 Start of the separation process is possible by pushing the touch key „Prig. ON“ at the control unit.

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 25

4 Program logic

4.1 Program Logic - Symbols …- 0136 - … .................................................26


4.2 Program Logic - Symbols …- 0196 - … .................................................32
4.3 Program Logic - Symbols …- 91 - … .....................................................38

GEA Mechanical Equipment / GEA Westfalia Separator


26 8555-9201-140 / 1010

4.1 Program Logic - Symbols …- 0136 - …

Location: Symbol: Name of Component:

Water feed PCV1 Pressure reducing valve


V2 Filling-, Displacement water valve
V3 Operating water valve

Dirty oil feed V4 Preset valve


V1 Feed valve
TI Temperature indicator
TT Temperatur Transmitter

Clean oil discharge PI1 Pressure indicator


PT1 Pressure transmitter
V7 Clean oil discharge valve (option)

Dirty oil recirculation - -

Sensing line V5 Circulation valve


V6 Water discharge valve
WMS Water monitoring sensor
PT2 Presssure transmitter (SMS)
PI2 Pressure indicator (option)

Sludge tank LSHH Level switch high high


LSH Level switch high
LSL Level switch low

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 27

Diagram …- 0136 -… Chapter “A”

A A
Power supply
ON

Selftest
Control Unit

Motor Start button activated


Pump Start button activated
Separator Start (T10)
Water impuls by Start (T19)

Closing water program


Closing water interval (T14)
Closing water impuls (T06)
Process
options
activated
D

“Prog. ON” key activated

Start of
Sensor Check Sequence
Precondition:
Oil temperature > TSL setpoint
Oil temperature < TSH setpoint
LSHH not activated
Vibro II not activated
B

GEA Mechanical Equipment / GEA Westfalia Separator


28 8555-9201-140 / 1010

Diagram …- 0136 -… Chapter “B”

B
B
Start of
Separation sequence

Process
monitoring
activated
E
Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Closing water impulse (T06)


Separation (T20)
Bridging after ejection (T11)

SMS Sensor PT 2 activated


Circulation valve closes (T15)
Circulation valve opens (T16)

Stop of separation sequence


C

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 29

Diagram …- 0136 -… Chapter “C”

C
C
Stop of separation sequence

“Prog. OFF” key activated or


Motor OFF activated or
SMS filling Counter 3 elapsed or
Flushing Counter 1 elapsed

Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Separator
Ready for operation
A

GEA Mechanical Equipment / GEA Westfalia Separator


30 8555-9201-140 / 1010

Diagram …- 0136 -… Chapter “D”

D
D
Process
options
activated

Separator OFF Motor OFF


mode activated Button activated

Separator OFF mode Motor OFF


Separator OFF (T39) A

Alarm
Separator OFF activated
after (T39)
A

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 31

Diagram …- 0136 -… Chapter “E”

E
E
Process
monitoring
activated

PAL / PAH or LSHH activated LSL / LSH activated


TAL / TAH activated LSHH Sludge tank (T18) Start of Sludge pump
Alarm delay (T07) Total ejection (T04) Sludge pump delay (T24)
Sludge pump OFF
Option CU:
CU-Sludgepump On (T40)
CU-Sludgepump Off (T41)

CU = Compact Unit
Alarm
PAL / PAH
TAL / TAH
LAHH
A

GEA Mechanical Equipment / GEA Westfalia Separator


32 8555-9201-140 / 1010

4.2 Program Logic - Symbols …- 0196 - …

Location: Symbol: Name of Component:

Water feed PCV1 Pressure reducing valve


V2 Filling-, Displacement water valve
V3 Operating water valve

Dirty oil feed V4 Preset valve


V1 Feed valve
TI Temperature indicator
TT Temperatur Transmitter

Clean oil discharge PI1 Pressure indicator


PT1 Pressure transmitter
V7 Clean oil discharge valve (option)

Dirty oil recirculation - -

Sensing line V5 Circulation valve


V6 Water discharge valve
WMS Water monitoring sensor
PT2 Presssure transmitter (SMS)
PI2 Pressure indicator (option)

Sludge tank LSHH Level switch high high


LSH Level switch high
LSL Level switch low

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 33

Diagram …- 0196 -… Chapter “A”

A
A
Power supply
ON

Selftest
Control Unit

Motor Start button activated


Pump Start button activated
Separator Start (T10)
Water impuls by Start (T19)

Closing water program


Closing water interval (T14)
Closing water impuls (T06)

Process
optionens
activated
D

“Prog. ON” key activated

Start of
Sensor Check Sequence
Precondition:
Oil temperature > TSL setpoint
Oil temperature < TSH setpoint
LSHH not activated
Vibro II not activated
B

GEA Mechanical Equipment / GEA Westfalia Separator


34 8555-9201-140 / 1010

Diagram …- 0196 -… Chapter “B”

B
B
Start of
Separation sequence

Process
monitoring
activated
E
Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Separation program
Closing water impulse (T06)
Filling water (T02)
Waiting after filling (T09)
Separation (T20)
Sensor flushing (T38)
Bridging after ejection (T11)

SMS Sensor PT2 not activated


WMS Mode (T32)
SMS Mode (T33)
SMS pressure check (T36)
SMS waiting (T37)

Stop of separation sequence


C

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 35

Diagram …- 0196 -… Chapter “C”

C
C
Stop of separation sequence

“Prog. OFF” key activated or


Motor OFF activated or
SMS filling Counter 3 elapsed or
Flushing counter 1 elapsed
Sensor Check not okay

Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Separator
Ready for operation
A

GEA Mechanical Equipment / GEA Westfalia Separator


36 8555-9201-140 / 1010

Diagram …- 0196 -… Chapter “D”

D
D
Process
options
activated

Separator OFF Motor OFF


mode activated Button activated

Separator OFF mode Motor OFF


Separator OFF (T39) A

Alarm
Separator OFF activated
after (T39)
A

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 37

Diagram …- 0196 -… Chapter “E”

E
E
Process
monitoring
activated

PAL / PAH or LSHH activated LSL / LSH activated


TAL / TAH activated LSHH Sludge tank (T18) Start of Sludge pump
Alarm delay (T07) Total ejection (T04) Sludge pump delay (T24)
Sludge pump OFF
Option CU:
CU-Sludgepump On (T40)
CU-Sludgepump Off (T41)

CU = Compact Unit
Alarm
PAL / PAH
TAL / TAH
LAHH
A

GEA Mechanical Equipment / GEA Westfalia Separator


38 8555-9201-140 / 1010

4.3 Program Logic - Symbols …- 91 - …

Location: Symbol: Name of Component:

Water feed PCV1 Pressure reducing valve


V2 Filling-, Displacement water valve
V3 Operating water valve

Dirty oil feed V4 Preset valve


V1 Feed valve
TI Temperature indicator
TT Temperatur Transmitter

Clean oil discharge PI1 Pressure indicator


PT1 Pressure transmitter
V7 Clean oil discharge valve (option)

Dirty oil recirculation - -

Sensing line PT2 Presssure transmitter (PAH)


PI2 Pressure indicator (option)

Sludge tank LSHH Level switch high high


LSH Level switch high
LSL Level switch low

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 39

Diagram …- 91 -… Chapter “A”

A
A
Power supply
ON

Selftest
Control Unit

Motor Start button activated


Pump Start button activated
Separator Start (T10)
Water impuls by Start (T19)

Closing water program


Closing water interval (T14)
Closing water impuls (T06)

Process
optionens
activated
D

“Prog. ON” key activated

Start of
Separation Sequence
Precondition:
Oil temperature > TSL setpoint
Oil temperature < TSH setpoint
LSHH not activated
Vibro II not activated
B

GEA Mechanical Equipment / GEA Westfalia Separator


40 8555-9201-140 / 1010

Diagram …- 91 -… Chapter “B”

B
B
Start of
Separation sequence
Process
monitoring
activated
E
Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Separation program
Closing water impulse (T06)
Filling water (T02)
Waiting after filling (T09)
Separation (T20)
Bridging after ejection (T11)

SMS Sensor PT2 not activated


Separation (T20)

Stop of Separation sequence


C

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 41

Diagram …- 91 -… Chapter “C”

C
C
Stop of Separation sequence

“Prog. OFF” key activated or


Motor OFF activated or
Flushing Counter 1 elapsed

Ejection program
Waiting - Start (T03)
Displacement (T01)
Waiting after displacement (T08)
Total ejection (T04)
Waiting after first ejection (T12)
Total ejection (T04)
Speed recovery (T05)

Separator
Ready for operation
A

GEA Mechanical Equipment / GEA Westfalia Separator


42 8555-9201-140 / 1010

Diagram …- 91 -… Chapter “D”

D
D
Process
options
activated

Separator OFF Motor OFF


mode activated Button activated

Separator OFF mode Motor OFF


Separator OFF (T39) A

Alarm
Separator OFF activated
after (T39)
A

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 43

Diagram …- 91 -… Chapter “E”

E
E
Process
monitoring
activated

PAL / PAH or LSHH activated LSL / LSH activated


TAL / TAH activated LSHH Sludge tank (T18) Start of Sludge pump
Alarm delay (T07) Total ejection (T04) Sludge pump delay (T24)
Sludge pump OFF
Option CU:
CU-Sludgepump On (T40)
CU-Sludgepump Off (T41)

Alarm
PAL / PAH CU = Compact Unit
TAL / TAH
LAHH
A

GEA Mechanical Equipment / GEA Westfalia Separator


44 8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 45

5 Trouble Shooting - Operating faults summary

5.1 Alarm overview .......................................................................................46


5.2 Alarm #00 - Know-How Protection .........................................................47
5.3 Alarm #01 - Motor Protection .................................................................48
5.4 Alarm #05 - TAL Oil Feed ......................................................................49
5.5 Alarm #06 - TAH Oil Feed ......................................................................50
5.6 Alarm #07 - Ejection Monitoring .............................................................51
5.7 Alarm #08 - LAHH Sludge Tank .............................................................52
5.8 Alarm #09 - Feed Pump Fault ................................................................53
5.9 Alarm #10 - Sludge Pump Fault .............................................................54
5.10 Alarm #11 Vibration Stage 1 ..................................................................55
5.11 Alarm #12 Vibration Stage 2 ..................................................................56
5.12 Alarm #15 - WMS system Fault .............................................................57
5.13 Alarm #18 - Bowl Monitoring ..................................................................58
5.14 Alarm #19 - Separator Motor Off ............................................................59
5.15 Alarm #22 - Excessive Running Time Of Sludge Pump ........................60
5.16 Alarm #23 - WMS Activated Too Often ..................................................61
5.17 Alarm #27 - Maintenance .......................................................................62
5.18 Alarm #28 - Warning Water content.......................................................63
5.19 Alarm #31 - TAL Oil Feed Warning ........................................................64
5.20 Alarm #32 - TAH Oil Feed Warning .......................................................65
5.21 Alarm #33 - Ejection Monitoring .............................................................66
5.22 Alarm #34 - Bowl Monitoring speed .......................................................67
5.23 Alarm #35 - Motor Start monitoring ........................................................68
5.24 Alarm #36 - Belt monitoring ...................................................................69
5.25 Alarm #37 - Max.- speed monitoring ......................................................70
5.26 Alarm #38 - Min.- speed monitoring .......................................................71
5.27 Alarm #39 - PT 1 Monitoring ..................................................................72
5.28 Alarm #40 - No Water Seal ....................................................................73
5.29 Alarm #41 - Min. Separating Time .........................................................74
5.30 Alarm #42 - SMS Sensor Fault ..............................................................75
5.31 Alarm #43 - SMS Sensor Active ............................................................76
5.32 Alarm #44 - PAL 1 Clean Oil Discharge.................................................77
5.33 Alarm #45 - PAH 1 Clean Oil Discharge ................................................78
5.34 Alarm #46 - EMERGENCY STOP .........................................................79
5.35 Alarm #48 - Water discharge overflow ...................................................80
5.36 Alarm #49 - MAINTENANCE required WMS Sensor .............................81

GEA Mechanical Equipment / GEA Westfalia Separator


46 8555-9201-140 / 1010

5.1 Alarm overview


Active in
Alarm No. Designation
-0136- -0196- -91-
#00 Know-How Protection X X X
#01 Motor Protection X X X
#05 TAL OIL Feed X X X
#06 TAH OIL Feed X X X
#07 Ejection Monitoring X X X
#08 LAHH Sludge Tank X X X
#09 Feed Pump Fault X X X
#10 Sludge Pump Fault X X X
#11 Vibration Stage 1 X X X
#12 Vibration Stage 2 X X X
#13 Fault Series Operation X --- ---
#15 WMS System Fault X X ---
#18 Bowl Monitoring X X X
#19 Separator Motor Off X X X
#22 Excessive Running Time Of Sludge Pump X X X
#23 WMS Activated Too Often X X ---
#27 Maintenance X X X
#28 Water content --- X ---
#31 TAL Oil Feed Warning X X X
#32 TAH Oil Feed Warning X X X
#33 Ejection Monitoring X X X
#34 Bowl Monitoring speed X X X
#35 Motor Start monitoring X X X
#36 Belt monitoring X X X
#37 Max.- speed monitoring X X X
#38 Min.- speed monitoring X X X
#39 PT 1 Monitoring X X X
#40 No Water Seal --- X ---
#41 Min. Separating Time X --- ---
#42 SMS Sensor Fault X X ---
#43 SMS Sensor Active X X ---
#44 PAL 1 Clean Oil Discharge X X X
#45 PAH 1 Clean Oil Discharge X X X
#46 EMERGENCY STOP X X X
#48 Water discharge overflow --- --- X
#49 MAINTENANCE required WMS Sensor X X ---

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 47

5.2 Alarm #00 - Know-How Protection


No. Time Status
2xxx hh:mm:ss IQ
KNOW-HOW PROTECTION No GEA-specific device. No warranty by operation!
Alarm#00 press HELP for info

Display shows Possible causes Remedy


• No GEA-specific device Use only GEA specific device!
• No warranty by operation ! Contact customer service!

Help text – Information on control

Step 1 Open HELP - menu

KNOW-HOW PROTECTION
No GEA-specific device
No warranty by operation!
Alarm#00 Please check:
Contact Westfalia
customer service !

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


48 8555-9201-140 / 1010

5.3 Alarm #01 - Motor Protection


No. Time Status
2xxx hh:mm:ss IQ
MOTOR PROTECTION Temp. > max temp. Motor shut off
Alarm#01 press HELP for info

Display shows Possible causes Remedy


• No motor protection switch signal Check functionality of motor protection
switch
• Brake not released Release brake
• Thermistor relay has triggered Check thermistor relay and cabling
• Operating water valve V2 open Check operating water valve V2
• Drive blocked Check drive
• Wrong number of clutch shoes Check number of clutch shoes
• Feed capacity too high Check capacity
• Motor ventilation not adequate Improve motor ventilation

• max temp. = see motor plate

Help text – Information on control

Step 1 Open HELP - menu

MOTOR PROTECTION
Alarm#01 Please check:
Motor protection function / Brake
Thermistor relay / Operating water
Valve V2 / No. of clutch shoes
Drive blocked / Feed capacity
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 49

5.4 Alarm #05 - TAL Oil Feed


No. Time Status
2xxx hh:mm:ss IQ
TAL OIL FEED Temp. < min Separation - Stop
Alarm#05 press HELP for info
x and yy = system data

Display shows Possible causes Remedy


Oil too cold before pre-heater • Check settling tank temperature
Feed capacity too high • Check feed capacity
Setting TAL has been set too high • Check setting TAL
Temperature of heating medium is too • Check temperature of heating me-
low dium
Temperature regulator defective • Check temperature regulator
E-pre-heater basic load or regulating • Check switching stages electrically
stage switched
Pre-heater dirty • Check pre-heater
PT100 sensor defective • Check sensor

Help text – Information on control

Step 1 Open HELP - menu

TAL OIL FEED


Alarm#05 Please check:
Settling tank temp. / Feed capacity
Setting TAL / Temp. of heating medium
Temp. regulator def./ Switching stages
elect. pre-heater / PT 100 sensor
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


50 8555-9201-140 / 1010

5.5 Alarm #06 - TAH Oil Feed


No. Time Status
2xxx hh:mm:ss IQ
TAH OIL FEED Temp. > max Separation - Stop
Alarm#06 press HELP for info

Display shows Possible causes Remedy


Oil too hot • Check regulating valve
Feed capacity too low • Check feed capacity
Setting TAH too low • Check setting TAH
E-pre-heater basic load or regulating • Check switching stages electrically
stages switched
Temperature regulator defective • Check temperature regulator
PT 100 sensor defective • Check PT 100 sensor

Help text – Information on control

Step 1 Open HELP - menu

TAH OIL FEED


Alarm#06 Please check:
Regulating valve / Feed capacity
Setting TAH / Switching stages electr.
Temp. regulator def./
PT 100 sensor
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 51

5.6 Alarm #07 - Ejection Monitoring


No. Time Status
2xxx hh:mm:ss IQ
EJECTION MONITORING Eject. current < Offset
Alarm#07 press HELP for info
x and yy = system data

Display shows Possible causes Remedy


Operating water valve V3 does not • Check function bowl hydraulics with
open valve V3
Connector on valve V3 loose • Check connector on V3
Offset setting for discharge current too • Check offset setting
high
Water quantity at V3 too low • Check water quantity
Setting of monitoring time for timer 28 • Check timer 28
is too short
Current evaluation defective • Check current converter electrically
Pre-strainer at V3 dirty • Check pre-strainer
Clutch shoes worn or oily • Check clutch shoes

Help text – Information on control

Step 1 Open HELP - menu

EJECTION MONITORING
Alarm#07 Please check:
Function of bowl / Hydraulics with V3
Connector valve V3 / Current offset setting/
Water quantity / TIMER 28
Current converter / Pre-strainer
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


52 8555-9201-140 / 1010

5.7 Alarm #08 - LAHH Sludge Tank


No. Time Status
2xxx hh:mm:ss IQ
LAHH SLUDGE TANK Sludge tank – full Separation - Stop
Alarm#08 press HELP for info

Display shows Possible causes Remedy


Sludge pump not functioning • Check sludge pump
Bowl is open • Check bowl hydraulics
Oil overflow due to excessive clean oil • Check valves in the clean oil line
discharge pressure and setting V7
Closing water pulse T06 too long • Check closing water pulse T06
Polyamide sealing ring defective • Check polyamide sealing ring
Sealing rings in the bowl defective • Check sealing rings
Level switch LSHH dirty or defective • Check level switch LSHH

Help text – Information on control

Step 1 Open HELP - menu

LAHH SLUDGE TANK


Alarm #08 Please check:
Sludge pump / Bowl hydraulics
Valves in the clean oil line
Setting V7 / Closing water pulse
Polyamide sealing ring / Switch LSHH
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 53

5.8 Alarm #09 - Feed Pump Fault


No. Time Status
2xxx hh:mm:ss IQ
FEED PUMP FAULT Motor protection Separation - Stop
Alarm#09 press HELP for info

Display shows Possible causes Remedy


Pump overloaded • Check protection switch current of
motor circuit breaker
Pump mechanically blocked • Check pump
Valves in the feed line closed • Check valves
Feed temperature • Check feed temperature
Filter in feed line dirty • Check filter
Electrical connections wrong • Check electrical connections and
cabling

Help text – Information on control

Step 1 Open HELP - menu

FEED PUMP FAULT


Alarm #09 Please check:
Protection switch / Current consumption/
Pump / Valves / Feed temperature / Filter
Electr. connections / Cabling
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


54 8555-9201-140 / 1010

5.9 Alarm #10 - Sludge Pump Fault


No. Time Status
2xxx hh:mm:ss IQ
SLUDGE PUMP FAULT Program - Stop
Alarm#10 press HELP for info

Display shows Possible causes Remedy


Pump overloaded • Check protection switch and current
of circuit breaker
Pump mechanically blocked • Check pump
Valves in the discharge line closed • Check valves
Pipe work dirty • Check pipe work
Electrical connections wrong • Check electrical connections and
cabling

Help text – Information on control

Step 1 Open HELP - menu

SLUDGE PUMP FAULT


Alarm #10 Please check:
Protection switch / Current consumption /
Pump / Valves / Pipe work
Electrical connection / Cabling
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 55

5.10 Alarm #11 Vibration Stage 1


No. Time Status
2xxx hh:mm:ss IQ
VIBRATION STAGE 1: Motor off after T25
Alarm#11 press HELP for info

Display shows Possible causes Remedy


Limit value 1 longer than T25 • Check T25
Uneven solid deposits in the bowl • Check solids holding space and
polyamide sealing ring
Vibrosensor has become detached • Check sensor fixing
Limit value 1 set to low • Check setting
Bowl not properly assembled or dam- • Open and clean bowl, assemble in
aged or wrong parts of other bowl accordance with operating instruc-
tions; use only parts with the same
series number
External vibrations • Check foundation fixing

Help text – Information on control

Step 1 Open HELP - menu

VIBRATION STAGE 1
Alarm#11 Please check:
TIMER 25 / Solids holding space
Polyamide sealing ring / Sensor
Fixing / Limit value 1 / Correct
bowl parts / Foundation fixing
Press ESC then ACK

or
Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


56 8555-9201-140 / 1010

5.11 Alarm #12 Vibration Stage 2


No. Time Status
2xxx hh:mm:ss IQ
VIBRATION STAGE 2: Separator – off
Alarm#12 press HELP for info

Display shows Possible causes Remedy


Setting of limit value 2 is too low • Check setting
Irregular solid deposits in the bowl • Check solids holding space and
polyamide sealing ring
Vibrosensor has become detached • Check sensor fixing
Bowl not properly assembled or dam- • Open and clean bowl, assemble in
aged or wrong parts of other bowl accordance with operating instruc-
tions; use only parts with the same
series number
External vibrations • Check foundation fixing

Help text – Information on control

Step 1 Open HELP - menu

VIBRATION STAGE 2
Alarm #12 Please check:
Limit value 2 / Solids holding space
Polyamide sealing ring / Sensor
Fixing / Correct bowl parts
Foundation fixing
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 57

5.12 Alarm #15 - WMS system Fault


No. Time Status
2xxx hh:mm:ss IQ
WMS SYSTEM FAULT Too much water Separation - Stop
Alarm#15 press HELP for info

Display shows Possible causes Remedy


Water content in oil feed too high • Check oil feed
Too much filling water setting of T02 • Check T02
too long
Filling water valve V2 leaking • Check filling water valve V2
Setting of timer T22 too short • Check setting In an emer-
ency,extend T22 during this phase

Help text – Information on control

Step 1 Open HELP - menu

WMS SYSTEM FAULT


Alarm#15 Please check:
Water content in oil feed
Filling water quantity / Setting T02
Valve V2 / Setting T22
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


58 8555-9201-140 / 1010

5.13 Alarm #18 - Bowl Monitoring


No. Time Status
2xxx hh:mm:ss IQ
BOWL MONITORING Current > Offset during TIMER 06
Alarm#18 press HELP for info

Display shows Possible causes Remedy


T06 closing water pulse too long, bowl • Check T06
has opened
Current offset bowl monitoring too low • Check current offset

Frequency of main power supply not • Check frequency of main power


stable supply
Water pressure for hydraulics during • Check water pressure with open
T06 too high, bowl has opened valve V3
Valve V3 is dirty, sticks, stays open for • Check valve V3
too long
New clutch shoes installed • Check current value
New belt installed • Check current value
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

BOWL MONITORING
Alarm#18 Please check:
TIMER T06 / Current offset
Frequency power supply
Water pressure for hydraulic
Function V3
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 59

5.14 Alarm #19 - Separator Motor Off


No. Time Status
2xxx hh:mm:ss IQ
SEP. MOTOR OFF Sep. in circulation T 39 expired M. off
Alarm#19 press HELP for info

Display shows Possible causes Remedy


Separator running in circulation T39 • Press program start before expiry of
has expired T39
Setting of T39 too short • Check T39
• In an emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

SEPARATOR MOTOR OFF


Alarm19# Please check:
TIMER 39 expired

Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


60 8555-9201-140 / 1010

5.15 Alarm #22 - Excessive Running Time Of Sludge Pump


No. Time Status
2xxx hh:mm:ss IQ
EXCESSIVE RUNNING TIME OF SLUDGE PUMP In TR3 h.
Alarm#22 press HELP for info

Display shows Possible causes Remedy


Setting of TR2 time recording too short • Check TR2 time recording
Bowl leakage • Check bowl function/hydraulics
Excessive water content in feed • Dewater product upstream of the
separator
Light oil overflow because clean oil • Check setting of clean oil discharge
discharge pressure too high pressure
Capacity of sludge pumps too low • Check pump function

Note:
TR2 = Time record of sludge pump operation, TR2 will be deleted when
TR3 has expired.
TR3 = Time counter factory setting 24 h

Help text – Information on control

Step 1 Open HELP - menu

EXCESSIVE RUN.TIME OF SLUDGE PUMP


Alarm#22 Please check:
TR2 time recording / Bowl function
Bowl leakage
Water content in Oil
Pump function
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 61

5.16 Alarm #23 - WMS Activated Too Often


No. Time Status
2xxx hh:mm:ss IQ
WMS ACTIVATED TOO OFTEN
Alarm#23 press HELP for info

Display shows Possible causes Remedy


Setting of TR1 time recording too short • Check TR1 time recording
Water content in oil too high • Dewater oil feed of the separator
Valve V2 not tight • Check V2

Note:
TR1 = Time record of WMS water sensor during HFO operation, TR1 will be
deleted when TR3 has expired.
TR3 = Time counter factory setting 24 h

Help text – Information on control

Step 1 Open HELP - menu

WMS ACTIVATED TOO OFTEN


Alarm#23 Please check:
TR1 time recording
Water content in Oil
Valve V2 is not tight

Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


62 8555-9201-140 / 1010

5.17 Alarm #27 - Maintenance


No. Time Status
2xxx hh:mm:ss IQ
MAINTENANCE required see manual
Alarm#27 press HELP for info

Display shows Possible causes Remedy


Operating hours have reached • Carry out maintenance according
– 4 000, manual
– 8 000, • Order spare parts from GEA West-
– 12 000, falia Separator Systems
– 16 000 • Order service from GEA Westfalia
or multiple hours. Separator Systems

Help text – Information on control

Step 1 Open HELP - menu

MAINTENANCE required
Alarm#27 Please check:
Operating hours have reached
4000; 8000; 12000; 16000 hours
or multiple / Carry out maintenance
according manual
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 63

5.18 Alarm #28 - Warning Water content


No. Time Status
2xxx hh:mm:ss IQ
WARNING WATER CONTENT
Alarm#28 press HELP for info

Display shows Possible causes Remedy


Water content in oil increased. • Dewater oil and check reason
T47 too long not consistent timer list • Check setting T47
Filling water valve V2 not tight • Check valve V2

Help text – Information on control

Step 1 Open HELP - menu

WARNING WATER CONTENT


Alarm#28 Please check:
Water content in Oil
Setting TIMER 47 and feed capacity
Valve V2 is not tight

Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


64 8555-9201-140 / 1010

5.19 Alarm #31 - TAL Oil Feed Warning


No. Time Status
2xxx hh:mm:ss IQ
TAL OIL FEED Temp. < min WARNING
Alarm#31 press HELP for info

Display shows Possible causes Remedy


Oil too cold before pre-heater • Check settling tank temperature
• (Settling tank applies to HFO only)
Feed capacity too high • Check feed capacity
Setting TAL has been set too high • Check setting TAL
Temperature of heating medium • Check temperature of heating me-
is too low dium
Temperature regulator defective • Check temperature regulator
E-pre-heater basic load or regulating • Check switching stages electrically
stage switched
Pre-heater dirty • Check pre-heater
PT100 sensor defective • Check sensor

Help text – Information on control

Step 1 Open HELP - menu

TAL OIL FEED


Alarm#31 Please check:
Settling tank temp. / Feed capacity
Setting TAL / Temp. of heating medium
Temp. regulator def. / Switching stages el.
pre-heater / PT 100 sensor
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 65

5.20 Alarm #32 - TAH Oil Feed Warning


No. Time Status
2xxx hh:mm:ss IQ
TAH OIL FEED Temp. > max WARNING
Alarm#32 press HELP for info

Display shows Possible causes Remedy


Oil too hot • Check regulating valve
Feed capacity too low • Check feed capacity
Setting TAH too low • Check setting TAH
E-pre-heater basic load or regulating • Check switching stages electrically
stage switched
Temperature regulator defective • Check temperature regulator
PT100 sensor defective • Check PT 100 sensor

Help text – Information on control

Step 1 Open HELP - menu

TAH OIL FEED


Alarm#32 Please check:
Regulating valve / Feed capacity
Setting TAH / Switching stages el.
Temp. regulator def.
PT 100 sensor
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


66 8555-9201-140 / 1010

5.21 Alarm #33 - Ejection Monitoring


No. Time Status
2xxx hh:mm:ss IQ
EJECTION MONITORING Eject. speed < Offset Sep. - Stop
Alarm#33 press HELP for info

Display shows Possible causes Remedy


Operating water valve V3 does not • Check function bowl hydraulics
open with valve V3
Connector on valve V3 loose • Check connector on V3
Seep offset ejection monitoring too • Check speed offset
high
Water quantity at V3 too low • Check water quantity
Setting of monitoring time for timer • Check timer 28
28 is too short
Speed pick-up sensor defective • Check speed pick -up sensor elec-
trically
Pre-strainer at V3 dirty • Check pre-strainer
Clutch shoes worn or oily • Check clutch shoes

Help text – Information on control

Step 1 Open HELP - menu

EJECTION MONITORING
Alarm#33 Please check:
Function of bowl / Hydraulics with V3
Connector valve V3 / Speed offset eject.
Water quantity / TIMER 28 / Speed pick- up
defective / Pre-strainer
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 67

5.22 Alarm #34 - Bowl Monitoring speed


No. Time Status
2xxx hh:mm:ss IQ
BOWL MONITORING Speed drop > Offset during T 06
Alarm#34 press HELP for info

Display shows Possible causes Remedy


T06 closing water pulse too long, bowl • Check T06
has opened
Water pressure for hydraulics during • Check water pressure with open
T06 too high, bowl has opened valve V3
Speed offset bowl monitoring too low • Check speed offset
Valve V3 is dirty, sticks, stays open for • Check valve V3
too long
Speed pick- up sensor defective • Check speed pick- up sensor electri-
cally
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

BOWL MONITORING
Alarm#34 Please check:
TIMER T06 / Water pressure
for hydraulic / Speed offset
bowl monitoring / Function V3
Speed pick- up defective
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


68 8555-9201-140 / 1010

5.23 Alarm #35 - Motor Start monitoring


No. Time Status
2xxx hh:mm:ss IQ
SEPARATOR-START monitoring during TIMER 10
Alarm#35 press HELP for info

Display shows Possible causes Remedy


T10 separator start time too short • Check T10

Brake not unfastened • Check brake

Clutch shoes worn or oily • Check clutch shoes

Drive belt worn or oily • Check drive belt

Speed setting for sensor operation- • Check speed setting


speed too high •
Speed pick- up sensor defective • Check speed pick- up sensor electri-
cally

Help text – Information on control

Step 1 Open HELP - menu

SEPARATOR- START
Alarm#35 Please check:
TIMER T10 / Brake unfastened / Clutch
shoes oily / Drive belt oily / Speed setting
of operation speed / Speed pick-up defective
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 69

5.24 Alarm #36 - Belt monitoring


No. Time Status
2xxx hh:mm:ss IQ
BELT MONITORING Drive belt broken during start up
Alarm#36 press HELP for info

Display shows Possible causes Remedy


Drive belt defect • Check drive belt
Motor defect • Check motor electrically
Clutch shoes worn or oily • Check clutch shoes
Speed pick- up sensor defective • Check speed pick- up sensor electri-
cally
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

BELT MONITORING
Alarm#36 Please check:
Drive belt / Motor defect electrically
Clutch shoes worn or oily
Speed pick- up defective
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


70 8555-9201-140 / 1010

5.25 Alarm #37 - Max.- speed monitoring


No. Time Status
2xxx hh:mm:ss IQ
MAX.- SPEED MONITORING during operation
Alarm#37 press HELP for info

Display shows Possible causes Remedy


Actual speed higher than permissible • Check speed
speed for operation
Speed setting for maximum speed too • Check maximum speed setting
low
Frequency unstable • Check frequency
Drive assembly (50 or 60 Hz) of sepa- • Check separator configuration for
rator does not fit to existing frequency frequency against existing frequency
at site at site
Speed pick- up sensor defective • Check speed pick –up sensor elec-
trically
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

MAX.- SPEED MONITORING


Alarm#37 Please check:
Speed in operation / Max.- Speed setting/
Frequency unstable / Sep. configuration
frequency opposite to frequency at site
Speed pick- up defective
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 71

5.26 Alarm #38 - Min.- speed monitoring


No. Time Status
2xxx hh:mm:ss IQ
MIN.- SPEED MONITORING during operation
Alarm#38 press HELP for info

Display shows Possible causes Remedy


Actual speed lower than permissible • Check speed
speed for operation
Speed setting for minimum speed too • Check minimum speed setting
high
Frequency unstable • Check frequency
Drive assembly (50 or 60 Hz) of sepa- • Check separator configuration for
rator does not fit to existing frequency frequency against existing frequency
at site at site
Speed pick- up sensor defective • Check speed pick –up sensor elec-
trically
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

MIN.- SPEED MONITORING


Alarm#38 Please check:
Speed in operation / Max.- Speed setting
Frequency unstable / Sep. configuration
frequency opposite to frequency at site
Speed pick- up defective
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


72 8555-9201-140 / 1010

5.27 Alarm #39 - PT 1 Monitoring


No. Time Status
2xxx hh:mm:ss IQ
PT 1 MONITORING clean oil discharge Separation – Stop
Alarm#39 press HELP for info

Display shows Possible causes Remedy


No pressure drop on PT 1 during dis- • Check switching function
charge
PT 1 is dirty, sticks or is defective • Clean and check PT 1
Setting of PAL 1 is too low • Check setting PAL 1
No ejection and ejection monitoring has • Check bowl hydraulics and ejection
not responded monitoring
Back pressure in system too high • Check discharge pressure
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

PT 1 MONITORING
Alarm#39 Please check:
Switching function PT 1
PT 1 dirty / Setpoint PAL 1
Bowl hydraulics / Ejection
monitoring / Discharge pressure
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 73

5.28 Alarm #40 - No Water Seal


No. Time Status
2xxx hh:mm:ss IQ
NO WATER SEAL during TIMER 35 Separation - Stop
Alarm#40 press HELP for info

Display shows Possible causes Remedy


Clean oil discharge pressure too • Check clean oil discharge pressure
high, valve V7 closed too far
Filling water valve V2 does not open • Check function V2
Filling water quantity too low, e.g. • Check filling water quantity
other consumers at same time
Filling water valve V2 or filters dirty • Check valve V2 and filters
Water pressure for hydraulics too • Check water pressure with open
high or T06 too long valve and T06
Shift of separating zone – oil • Check temperature and setting of
temperature too low TAL
Wrong sensing centripetal pump in- • Check parts in accordance with op-
stalled erating instruction
Pressure sensor PT 2 bridged or set • Check setting PT 2
to 0

Help text – Information on control

Step 1 Open HELP - menu

NO WATER SEAL
Alarm#40 Please check:
Clean oil discharge pressure
Function V2 / Filling water quantity
Valve V2 and filter / Water pressure
TIMER T06 / Setting TAL / Setting PT 2
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


74 8555-9201-140 / 1010

5.29 Alarm #41 - Min. Separating Time


No. Time Status
2xxx hh:mm:ss IQ
MIN. SEPARATING TIME < 10 min. Separation - Stop
Alarm#41 press HELP for info

Display shows Possible causes Remedy


Pressure sensor PT 2 not connected, • Check switching function of pressure
dirty or defective sensor PT 2
Alarm bridging time T11 too short • Check T11
Setting PT 2 too high • Check setting on pressure sensor
PT 2
Water or solids content in the bowl too • Pre-dewater oil and/or check solids
high content
To much filling water • Check filling water quantity
With HFO and parallel operation, • Remove screws from separating disk
screws in the separating disk installed
Filling water valve V2 not tight • Check filling water valve V2
Orifice in centripetal pump chamber • Check orifice
cover plugged

Help text – Information on control

Step 1 Open HELP - menu

MIN. SEPARATING TIME


Alarm#41 Please check:
Pressure sensor PT 2 / TIMER 11
Setting PAL 2 / Water content
Valve V2 / Screws in separating disk
with HFO operation
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 75

5.30 Alarm #42 - SMS Sensor Fault


No. Time Status
2xxx hh:mm:ss IQ
SMS SENSOR FAULT during SMS Check during TIMER 44
Alarm#42 press HELP for info

Display shows Possible causes Remedy


PT 2 no pressure signal • Check setting PT 2
Filling water valve V2 no function • Check function V2
T44 too short • Check T44
Sludge holding space blocking pres- • Clean bowl, check drill hole in cen-
sure sensor line to PT 2 tripetal pump chamber lid
Bowl not closed • Check bowl hydraulics
Insufficient water quantity during T44 • Check water quantity
• (Timer T60 – T62)
Pressure sensor PT 2 defective • Check pressure sensor
Wrong switching point on PT 2 • Check switching point
• In emergency, deselect function

Help text – Information on control

Step 1 Open HELP - menu

SMS SENSOR FAULT


Alarm#42 Please check:
Setting PAL 2 / Function V2
Timer 44 / Solids holding space
Orifice in centripetal pump chamber
cover / Bowl hydraulics / Function PT 2
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


76 8555-9201-140 / 1010

5.31 Alarm #43 - SMS Sensor Active


No. Time Status
2xxx hh:mm:ss IQ
SMS SENSOR ACTIVE in Idle run
Alarm#43 press HELP for info

Display shows Possible causes Remedy


Pressure sensor PT 2 activated during • Check pressure sensor PT 2
idle run conditions?
Filling water valve V2 leaking • Check V2
Product valve V1 does not close prop- • Check valve V1
erly
Non-return valve at V7 open, product • Close pure oil discharge valve V7
flows back into the bowl under no load

Help text – Information on control

Step 1 Open HELP - menu

SMS SENSOR ACTIVE IN IDLE RUN


Alarm#43 Please check:
Pressure sensor PT 2 / Valve V2 is
not tight/ Valve V1 closes not
properly / Oil flows back into the bowl
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 77

5.32 Alarm #44 - PAL 1 Clean Oil Discharge


No. Time Status
2xxx hh:mm:ss IQ
PAL 1 CLEAN OIL DISCHARGE Pressure < setting
Alarm#44 press HELP for info

Display shows Possible causes Remedy


Clean oil discharge valve V7 opened • Check valve setting V7
too wide
Feed capacity reduced • Check feed capacity
Setting PT 1 for PAL 1 too high • Check setting PT 1 for PAL 1
see also PAH 1 alarm
Water pressure for hydraulics too high • Check water pressure with opened
during T06, bowl has opened valve V3
Safety pulse T06 too long, bowl has • Check TIMER 06
opened
Feed pump failure • Check feed pump
FU speed too low • Check pump speed
Feed valve V1 in circulation position • Check compressed air and signal
output for solenoid valve on V1
Breakover to water side • Check quantity of filling water
Direction of rotation of pump incorrect • Check direction of rotation
Bowl gaskets not sealed • Check and where necessary replace
gaskets
T07 alarm delay too short • Check whether T07 expires before
pressure builds up
T11 alarm bridging too short • Check TIMER 11 alarm bridging
FU = Frequency transformer

Help text – Information on control

Step 1 Open HELP - menu

PAL 1 CLEAN OIL DISCHARGE


Alarm#44 Please check:
Valve setting V7 / Feed capacity
Setting PT1 for PAL / Water pressure for
opened valve V3 / TIMER 06 /T07 alarm
delay / Quantity of water / Bowl not sealed
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


78 8555-9201-140 / 1010

5.33 Alarm #45 - PAH 1 Clean Oil Discharge


No. Time Status
2xxx hh:mm:ss IQ
PAH 1 CLEAN OIL DISCHARGE Pressure > setting
Alarm#45 press HELP for info

Display shows Possible causes Remedy


Clean oil discharge valve V7 closed • Check valve setting V7
too far
Feed capacity too high • Check feed capacity
Setting PT1 for PAH1 too low • Check setting PT 1 for PAH 1

T07 alarm delay too short • Check T07


T11 alarm bridging too short • Check T11 alarm bridging
Oil temperature too low • Check temperature in oil feed

Help text – Information on control

Step 1 Open HELP - menu

PAH 1 CLEAN OIL DISCHAGE


Alarm#45 Please check:
Valve setting V7 / Feed capacity
Setting PT1 for PAH 1 / T07 alarm delay
T11 alarm bridging /
Temperature oil feed
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 79

5.34 Alarm #46 - EMERGENCY STOP


No. Time Status
2xxx hh:mm:ss IQ
EMERGENCY STOP
Alarm#46 press HELP for info

Display shows Possible causes Remedy


Emergency Stop Button was pushed. • Check reason for pushing Emer-
gency Stop button.

Help text – Information on control

Step 1 Open HELP - menu

EMERGENY STOP
Alarm#46 Please check:
Emergency Button
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


80 8555-9201-140 / 1010

5.35 Alarm #48 - Water discharge overflow


No. Time Status
2xxx hh:mm:ss IQ
WATER DISCHARGE overflow separation - Stop
Alarm#48 press HELP for info

Display shows Possible causes Remedy


Clean oil discharge pressure too • Check valve V7 in clean oil dis-
high charge line
Water content in feed too high • Check product feed
Quantity of filling water too low • Check function V2 and quantity of
Water seal broken filling water
Product temperature too low • Check product temperature
Regulating ring too large • Install next smaller regulating ring
Polyamide sealing ring defective • Check polyamide sealing ring
Sealing rings in the bowl defective • Check sealing rings
Pressure sensor PT2 defective • Check pressure sensor PT2

Help text – Information on control

Step 1 Open HELP - menu

WATER DISCHARGE
Alarm#48 Please check:
Clean oil valve V7 / Water cont. in Oil
Filling water quantity / oil
Temperature / Regulating ring
Polyamide ring / Press. sensor PT2
Press ESC then ACK

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 81

5.36 Alarm #49 - MAINTENANCE required WMS Sensor


No. Time Status
2xxx hh:mm:ss IQ
MAINTENANCE required WMS Sensor
Alarm#49 press HELP for info

Display shows Possible causes Remedy


Monitoring time of WMS Sensor • WMS Sensor Check must be done
has reached limit without water indi- according to manual.
cation

Help text – Information on control

Step 1 Open HELP - menu

MAINTENANCE required WMS Sensor


Alarm#49 Please Check:
Monitoring time of WMS Sensor
has reached limit without water indication
Carry out maintenance
according to manual

or Step 2 Alarm acknowledgement

GEA Mechanical Equipment / GEA Westfalia Separator


82 8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 83

6 Alarm Simulation und Test

6.1 Alarms #01 - #10 ....................................................................................84


6.2 Alarms #11 - #20 ....................................................................................85
6.3 Alarms #21 - #30 ....................................................................................86
6.4 Alarms #31 - #40 ....................................................................................87
6.5 Alarms #41 - #50 ....................................................................................88

GEA Mechanical Equipment / GEA Westfalia Separator


84 8555-9201-140 / 1010

6.1 Alarms #01 - #10

SIMULATION AND TESTS OF VARIOUS ALARMS


Alarm display Status Mechanical Electrical Action

MOTOR PROTECTION Control Not possible Disconnect PTC sensor • Separation


Temp. > max temp. active stop
Motor switched off • V1 in circula-
Alarm#01 tion
• Common alarm
Free

Alarm#02

Free

Alarm#03

Free

Alarm#04

TAL PRODUCT FEED Separation Not possible Set setting higher than the • Separation
Temp. < min current temperature stop
Separation - Stop • V1 in circula-
Alarm#05 tion
• Common alarm
TAH PRODUCT FEED Separation Not possible Set setting lower than the • Separation
Temp. > max current temperature stop
Separation - Stop • V1 in circula-
Alarm#06 press ENTER tion
• Common alarm
EJECTION MONITORING Ejection Close manual ball valve Disconnect cable head of V3 • Separation
Current< Offset which is in front of V3 or increase offset Ejection stop
Separation – Stop shortly before and during current during discharge • V1 in circula-
ALARM#07 discharge cycle T04. cycle T04. tion
• Common alarm
LAHH SLUDGE TANK Control Immerse or dampen Disconnect cable head of • Separation
Sludge tank - full Active sensor LSHH. LSHH Sensor stop
Separation - Stop • V1 in circula-
Alarm#08 tion
• Common alarm
FEED PUMP FAULT Control Not possible Trigger motor protection • Separation
Motor protection Active switch stop
Separation - Stop • V1 in circula-
Alarm#09 press ENTER tion
• Common alarm
SLUDGE PUMP FAULT Control Not possible Trigger motor protection • Separation
Program - stop Active switch stop
• V1 in circula-
Alarm#10 tion
• Common alarm

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 85

6.2 Alarms #11 - #20

SIMULATION AND TESTS OF VARIOUS ALARMS


Alarm display Status Mechanical Electrical Action

VIBRATION STAGE 1: Separation Not possible Disconnect contact • Separation


Motor off after T25 Stop
• V1 in circula-
Alarm#11 tion
• Ejection
• Motor off aft.
T26
• Common alarm

VIBRATION – STAGE 2: Control Not possible Disconnect contact • Separation
Separator - Off Active stop
• V1 in circula-
Alarm#12 tion
• Common alarm

FAULT SERIES Control Not possible MPI Leitungsanschluss an • Separation
OPERATION Line or Active der Steuerung abklemmen. stop
preselection not OK • V1 in circula-
Alarm#13 tion
• Common alarm

Free

Alarm#14

WMS SYSTEM FAULT Separation Open valve V2 to add Bridge WMS Sensor and set • Separation
Too much water water into bowl until pressure sensor PT2 switch- stop
Separation - Stop Timer 22 is elapsed. ing point to 0 or bridge. • V1 in circula-
Alarm#15 tion
• Common alarm
• Ejection
Free

Alarm#16

Free

Alarm#17

BOWL MONITORING Separation Not possible. Extend T06 during separa- • Common alarm
Current too high tion and shorten T14 to •
during TIMER 06 300sec.! Wait until T14 is
Alarm#18 elapsed and Alarm appears.

SEPARATOR MOTOR OFF Circulation Not possible. Set TIMER 39 to 10 seconds • Common alarm
Sep. in circulation and push program stop • Motor off
T 39 expired M. off button.
Alarm#19

Free

Alarm#20

GEA Mechanical Equipment / GEA Westfalia Separator


86 8555-9201-140 / 1010

6.3 Alarms #21 - #30

SIMULATION AND TESTS OF VARIOUS ALARMS


Alarm display Status Mechanical Electrical Action

Free

Alarm#21

EXCESSIVE RUNNING Control Set TR2 to 1 minute and Set TR2 to 1 minute • Common alarm
TIME OF SLUDGE PUMP Active immerse or dampen LSH Trigger testfunction with
In TR3 hours Sensor to start sludge magnet at testpoint of LSH
Alarm#22 pump until Alarm ap- sensor until Alarm appears.
pears.
WMS ACTIVATED Separation Set T22 to 300sec. and Set T22 to 300sec., TR1 to 1 • Common alarm
TOO OFTEN TR1 to 1 minute and minute and bridge WMS
open valve V2 to add sensor until Alarm appears.
Alarm#23 water into bowl until
Alarm appears.
Free •

Alarm#24

Free •

Alarm#25

Free •

Alarm#26

Maintenance Separation Not possible. Set value to actual value • Message in the
required see manual plus 1hour and wait 1hour. display

Alarm#27

WARNING Separation Set T17 to 1s and Set T17 to 1s and • Message in the
WATER CONTENT set counter 5 to 1 and set counter 5 to 1 and display
T47 to 60sec.than open bridge pressure sensor • V6 opens
Alarm#28 valve V2 for 10sec. to PSL2 or set optional PT2 to
add water into bowl until 0 and 1 in short intervals
warning appears. during T47 for minimum 2
times, so that warning ap-
pears.
Free

Alarm#29

Free

Alarm#30

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 87

6.4 Alarms #31 - #40

SIMULATION AND TESTS OF VARIOUS ALARMS


Alarm display Status Mechanical Electrical Action

Free

Alarm#31

Free

Alarm#32

EJECTION MONITORING Ejection Close manual ball valve Disconnect cable head of V3 • Separation
Eject. speed < Offset which is in front of V3 or increase offset Ejection stop
Separation – Stop shortly before and during speed during discharge • V1 in circula-
Alarm#33 discharge cycle T04. cycle T04. tion
• Common alarm
BOWL MONITORING Separation Not possible. Extend T06 during separa- • Common alarm
Speed drop too high tion and shorten T14 to •
during TIMER 06 300sec.! Wait until T14 is
Alarm#34 elapsed and Alarm appears.

SEPARATOR-START Separator Set Timer 10 to 10 sec. Set setting for min. speed • Motor off
monitoring Motor Start and press motor start higher than the normal • Message in the
during T10 button. operating speed. display
Alarm#35 • Common alarm

BELT MONITORING Separator Not possible. Disconnect speed pick-up • Motor off
Drive belt broken Motor Start sensor and press motor • Message in the
during start up start button. display
Alarm#36 • Common alarm

MAX.- SPEED Separator Not possible. Set setting for Max. Speed • Motor off
MONITORING Motor Start lower than normal operating • Message in the
during operation and Separa- speed, during start up or display
Alarm#37 tion during operation. • Common alarm

MIN.- SPEED Separator Not possible. Set setting for Min. Speed • Motor off
MONITORING Motor Start higher than normal operat- • Message in the
during operation and Separa- ing speed, display
Alarm#38 tion during start up or during • Common alarm
operation. •
PT 1 MONITORING Ejection Not possible. Set pressure sensor PT1 • Separation
clean oil discharge switching point to 0 while stop
Separation - Stop ejection sequence is run- • V1 in circula-
Alarm#39 ning. tion
• Common alarm

NO WATER SEAL Separation Reduce T34 and T35 to 5 Set pressure sensor PT2 to • Separation
during TIMER 35 sec. and close hand 0 and disconnect cable of stop
Separation - Stop valve before V2 during WMS sensor. • V1 in circula-
Alarm#40 T02. tion
• Common alarm
• Ejection

GEA Mechanical Equipment / GEA Westfalia Separator


88 8555-9201-140 / 1010

6.5 Alarms #41 - #50

SIMULATION AND TESTS OF VARIOUS ALARMS


Alarm display Status Mechanical Electrical Action

MIN. SEPARATING TIME Separation Not possible. Disconnect cable head on • Separation
< 10 Min pressure sensor PT2 during stop
Separation - Stop T21. • V1 in circula-
Alarm#41 tion
• Common alarm
• Ejection
SMS SENSOR FAULT Sensor Close hand valve at V2 Disconnect cable head on • Common alarm
during SMS Check Check while test is running. pressure sensor PT2 while • Ejection
during TIMER 44 test is running.
Alarm#42
PT2 SENSOR ACTIVE Circulation Open valve V2 until pres- Set pressure sensor PT2 to • Message in the
in Idle run sure increase on pres- 0 during idle run. display
sure sensor PT2 during • Common alarm
Alarm#43 idle run. • Ejection

PAL1 CLEAN OIL DISCHARGE Separation Open clean oil discharge Disconnect cable head on • Separation
Pressure < setting valve V7 pressure sensor PT1 stop
Separation - Stop • V1 in circula-
Alarm#44 tion
• Common alarm
• Ejection
PAH 1 CLEAN OIL DISCHARGE Separation Close clean oil discharge Set pressure sensor PT1 • Separation
Pressure > setting valve V7 switching point to a lower stop
Separation - Stop value than the current value. • V1 in circula-
Alarm#45 tion
• Common alarm
• Ejection
EMERGENCY STOP Control Not possible. Push emergeny button. • All electric
Button pushed Active components
are shut down
ALARM#46 like Motors,
Control Units
ect!
FREE

ALARM#47
WATER DISCHARGE: Separation Close clean oil discharge Set pressure sensor PT1 • Separation
Overflow valve V7. Set optional PAH1 switching point to 0 while stop
Separation - Stop (PT1) in clean oil discharge separation sequence is
to 10 bar.
• V1 in circula-
Alarm#48 running. tion
• Common alarm
• Ejection
MAINTENANCE required Circulation Not possible. Set value to actual value • Message in the
WMS Sensor plus 1minute and wait display
1minute. Add extra water to
Alarm#49 get WMS Signal if neces-
sary.
Free

Alarm#50

For a simulation, the function must be activated and must be valid for the product.

ATTENTION:
After the simulation, all changes must be reset to the initial conditions!!!!

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 89

7 Ejection monitoring / Bowl monitoring

7.1 Graphic description Ejection- / Bowl monitoring - Motorcurrent:............90


7.2 Graphic description Ejection- / Bowl monitoring - Speed:......................91

GEA Mechanical Equipment / GEA Westfalia Separator


90 8555-9201-140 / 1010

7.1 Graphic description Ejection- / Bowl monitoring - Motorcurrent:

1: separator motor start

2: feed valve V1 open: sepa-


ration

3: feed valve V1 closed for


ejection

4: operating water valve V3


open for T04: ejection

5: feed valve V1 open: sepa-


ration

1: separator motor start

2: feed valve V1 open: sepa-


ration

3: operating water valve V3


open for T06: safety water
impuls

4: operating water valve V3


closed: separation

5: feed valve V1 closed:


ejection

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 91

7.2 Graphic description Ejection- / Bowl monitoring - Speed:

0: separator motor start

1: feed valve V1 open: sepa-


ration

2: feed valve V1 closed for


ejection

3: operating water valve V3


open for T04: ejection

4: feed valve V1 open: sepa-


ration

0: separator motor start

1: feed valve V1 open: sepa-


ration

2: operating water valve V3


open for T06: safety water
impuls

3: operating water valve V3


closed: separation

GEA Mechanical Equipment / GEA Westfalia Separator


92 8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 93

8 Bowl volumes / Speed setpoints

8.1 Bowl-Volumes ........................................................................................94


8.2 Speed setpoints .....................................................................................94

GEA Mechanical Equipment / GEA Westfalia Separator


94 8555-9201-140 / 1010

8.1 Bowl-Volumes

Separator type

OSE 5 OSE 10 OSE 20 OSE 40 OSE 80 OSE 120


HFO LO HFO LO HFO LO HFO LO HFO LO HFO LO

3
Volumes in dm
Bowl volume 1,00 1,00 2,00 2,00 3,60 3,60 10,00 10,00 23,00 23,00 40,00 40,00
Sludgespace volume 0,50 0,50 0,90 0,90 1,60 1,60 4,00 4,00 10,00 10,00 14,60 14,60
Fillingwater volume 0,20 0,50 0,30 0,90 0,40 1,60 0,50 4,00 1,00 10,00 3,00 14,60
Displacementwater
volume
0,50 0,50 1,10 1,10 2,00 2,00 6,00 6,00 13,00 13,00 25,40 25,40

8.2 Speed setpoints

Separator type
OSE 5 / OSE 10 / OSE 20 OSE 40 OSE 80 OSE 120
Speed in U/min
Max. Speed 12 200 8 400 7 000 6 100
Min. Speed 11 500 7 800 6 300 5 400
Rated Speed 12 000 8 200 6 800 5 900

Speed -Offset
100 100 100 100
Ejection monitoring
Speed -Offset
100 100 100 100
Bowl monitoring

GEA Mechanical Equipment / GEA Westfalia Separator


8555-9201-140 / 1010 95

GEA Mechanical Equipment / GEA Westfalia Separator


96 8555-9201-140 / 1010

GEA Mechanical Equipment / GEA Westfalia Separator


GEA Mechanical Equipment
GEA Westfalia Separator Group GmbH
Werner-Habig-Str. 1, 59302 Oelde
Tel. +49 2522 77-0, Fax +49 2522 77-2488
ws.info@geagroup.com, www.westfalia-separator.com
0 1 2 3 4 5 6 7 8 9

GEA Westfalia Separator


Werner-Habig-Str. 1 - 59302 Oelde ( Germany ) - Phone +49 2522 77-0

Customer : PDV Power Technology

Designation of plant : HFO Separator Double Unit (HFO 1)

Drawing no. : 8106-2011-061

Internal order no. : 1 451 119 792

Manufacturer (company) : GEA Westfalia Separator

Name of project : Esmeraldas II

Type : E40 / OSE 80-0136-067

Language : en

Technical data : 480V AC 60 Hz +/-5 % -

Prepared : 18.07.2012 Processed : 07.09.2012 Applied standards IEC 81346


IEC 61355
IEC 60617
GEA project contact : M. Kalb Telephone : +49 2522 77-2802

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Title- / cover sheet
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 1
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EAA 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Table of contents

Document type Page Page description Plant Mounting place Date Editor

&EAA 1 Title- / cover sheet 19.07.2012 GUE/PLE

&EAB 2 Table of contents 19.07.2012 GUE/PLE

&EAB 3 Table of contents 19.07.2012 GUE/PLE

&EAB 4 Table of contents 19.07.2012 GUE/PLE

&EAB 5 Table of contents 19.07.2012 GUE/PLE

&EBH 6 Revision overview 19.07.2012 GUE/PLE

&EDB 7 Structure indicator 19.07.2012 MAR/PLE

&EDB 8 Information-sheet 19.07.2012 GUE/PLE

&EDB 9 Information-sheet 19.07.2012 GUE/PLE

&EFS 10 Incoming =0 19.07.2012 GUE/PLE

&EFS 11 Control voltage =0 19.07.2012 GUE/PLE

&EFS 12 Emergency stop =0 19.07.2012 GUE/PLE

&EFS 13 Separator =01 19.07.2012 GUE/PLE

&EFS 14 Separator =01 19.07.2012 GUE/PLE

&EFS 15 Separator speed measuring =01 19.07.2012 GUE/PLE

&EFS 16 Separator signals =01 19.07.2012 GUE/PLE

&EFS 17 Separator vibro =01 19.07.2012 GUE/PLE

&EFS 18 Separator valves =01 19.07.2012 GUE/PLE

&EFS 19 Separator clean-oil discharge =01 19.07.2012 GUE/PLE

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Table of contents
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 2
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EAB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Table of contents

Document type Page Page description Plant Mounting place Date Editor

&EFS 20 Feed pump =11 19.07.2012 GUE/PLE

&EFS 21 Feed pump =11 19.07.2012 GUE/PLE

&EFS 22 Product temperature control =11 19.07.2012 GUE/PLE

&EFS 23 FI flow measuring =11 19.07.2012 GUE/PLE

&EFS 24 Sludge pump =16 19.07.2012 GUE/PLE

&EFS 25 Sludge pump =16 19.07.2012 GUE/PLE

&EFS 26 Signal exchange =100 19.07.2012 GUE/PLE

&EFS 27 Signal exchange =100 19.07.2012 GUE/PLE

&EFS 28 PLC overview =00 19.07.2012 GUE/PLE

&EFS 29 PLC overview =00 19.07.2012 GUE/PLE

&EFS 30 Process display OP 177B =00 19.07.2012 GUE/PLE

&EFS 31 PLC power supply =00 19.07.2012 GUE/PLE

&EFS 32 PLC overview =00 19.07.2012 GUE/PLE

&EFS 33 PLC overview =00 19.07.2012 GUE/PLE

&EFS 34 PLC overview =00 19.07.2012 GUE/PLE

&EFS 35 PLC overview =00 19.07.2012 GUE/PLE

&EFS 36 PLC overview =00 19.07.2012 GUE/PLE

&ELU 37 Arrangement drawing control cabinet 19.07.2012 GUE/PLE

&ELU 38 E40 19.07.2012 GUE/PLE

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Table of contents
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 3
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EAB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Table of contents

Document type Page Page description Plant Mounting place Date Editor

&EMA 39 Terminal connecting plan =0+-24M 19.07.2012 GUE/PLE

&EMA 40 Terminal connecting plan =0+-024M 19.07.2012 GUE/PLE

&EMA 41 Terminal connecting plan =0+-PE 19.07.2012 GUE/PLE

&EMA 42 Terminal connecting plan =0+-PE 19.07.2012 GUE/PLE

&EMA 43 Terminal connecting plan =0+-SC 19.07.2012 GUE/PLE

&EMA 44 Terminal connecting plan =0+-X1 19.07.2012 GUE/PLE

&EMA 45 Terminal connecting plan =0+-XQ1 19.07.2012 GUE/PLE

&EMA 46 Terminal connecting plan =01+-X1 19.07.2012 GUE/PLE

&EMA 47 Terminal connecting plan =01+-X2 19.07.2012 GUE/PLE

&EMA 48 Terminal connecting plan =01+JB-1X10 19.07.2012 GUE/PLE

&EMA 49 Terminal connecting plan =01+SB-1X20 19.07.2012 GUE/PLE

&EMA 50 Terminal connecting plan =11+-X1 19.07.2012 GUE/PLE

&EMA 51 Terminal connecting plan =11+-X2 19.07.2012 GUE/PLE

&EMA 52 Terminal connecting plan =16+-X2 19.07.2012 GUE/PLE

&EMA 53 Terminal connecting plan =100+-X2 19.07.2012 GUE/PLE

&EMB 54 Cable layout 19.07.2012 GUE/PLE

&EMB 55 Cable layout 19.07.2012 GUE/PLE

&EMB 56 Instructions for installation 19.07.2012 GUE/PLE

&EMB 57 Potential equalization Separator 19.07.2012 GUE/PLE

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Table of contents
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 4
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EAB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Table of contents

Document type Page Page description Plant Mounting place Date Editor

&EPB 58 Parts list 19.07.2012 GUE/PLE

&EPB 59 Parts list 19.07.2012 GUE/PLE

&EPB 60 Parts list 19.07.2012 GUE/PLE

&EPB 61 Parts list 19.07.2012 GUE/PLE

&EPB 62 Parts list 19.07.2012 GUE/PLE

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Table of contents
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 5
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EAB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Revision overview

Revision name Revision comment Revision on the basis of change Page name Author Date

Rev.01 Customer comments included MAR/PLE 26.07.2012

Rev.02 Customer comments included MAR/PLE 27.07.2012

Rev.03 Customer comments included (Cable gland size) GUE/PLE 03.08.2012

Rev.04 Customer comments included (Cable cross-section) GUE/PLE 07.08.2012

Rev.05 / As built Factory revision GUE/PLE 07.09.2012

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Revision overview
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 6
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EBH 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Structure indicator

Complete name Labelling Structure descprition Complete name Labelling Structure descprition

&EAA Document type Cover sheet

&EAB Document type Table of contents

&EBH Document type Revision overview

&EDB Document type Structure indentification overview / instructions

&EFS Document type Circuit diagram

&ELU Document type Arrangement drawing

&EMA Document type Terminal connecting plan

&EMB Document type Cable layout

&EPB Document type Parts list

=0 Plant Incoming

=01 Plant Separator

=11 Plant Feed pump

=16 Plant Sludge pump

=100 Plant Signal exchange

=00 Plant PLC

=Additions Plant Addition

=Customer Plant Customer

+JB Mounting place Junction box

+L Mounting place Local

+SB Mounting place Sensor bloc

+HFO2 Mounting place HFO2 control cabinet

+DCS Mounting place

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Structure indicator
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 7
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EDB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Instruction / specification

Control cabinet : Version:

Name control cabinet HFO 1 Core indentification YES

Painting cabinet RAL 7035 Potential designation NO

Protective rating IP54 Halogen free wiring / channels NO

Ambient temperature ~45 °C Cable marking plates YES

Classification ...

Marking plates PLASTIC WHITE, LETTERS BLACK

Interface:

Bus connection to customer PLC NO

Incoming:

Mains- / side voltage 480V AC

Mains frequency 60 Hz

Rotary field

Voltage tolerance +/-5 %

Cable inlet BOTTOM

Incoming redundant NO

Control voltages:

Control voltage 1 220V AC

Control voltage 2 24V DC

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Information-sheet
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 8
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EDB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Wiring

Electrical circuits Conductor Colour Cross-section Electrical circuits Conductor Colour Cross-section

Main circuits 480V AC L1 Black ≥ 1,5mm² Control voltage 220V AC L Red ≥ 0,75mm²

L2 Black " N Red / white "


L3 Black "
N Light blue ≥ 1,5mm²

PE Green / yellow ≥ 2,5mm²

Control voltage 24V DC + Dark blue ≥ 0,75mm²

- Blue / white "

Analog screened L+ White ≥ 0,75mm²

M Brown "

Measuring circuit White ≥ 0,75mm²

Current transformer lines Black ≥ 2,5mm²

Interlocking conductors (AC/DC) Orange ≥ 0,75mm²

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Information-sheet
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 9
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EDB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

480V AC
L1 / 13.0
L2 / 13.0
L3 / 13.0
480V AC
L1.2 / 20.0
L2.2 / 11.0
L3.2 / 11.0

3
-F01

4
C6A

N/L2
L1
-T01
INPUT
120/230VAC GEA
24VDC/5A power

OFF

ON
A
B
OUTPUT

L+

L+'

PE

M'
12

14
1

-Q1
0M.R / 19.0
/26.1 11

56-80A -PE
In: 74A
I> I> I>

2
-024M
2

-PE
0M.T / 24.0
0M.X / 19.0
24V DC
0L+.A / 19.0
24V DC
0L+.X / 19.0
24V DC
0L+.T / 24.0

Data incoming 1: Data incoming 2:


-PE -PE -PE -SC -PE -PE -PE
1

-X1 Min. Cross-section: Min. Cross-section:


25 mm² 1,5 mm²

-X1_W1 -W001
Pre-fuse: Pre-fuse:
_-J _-J NH 80A 10 A
4x25 mm² 3x1,5 mm²
PE

PE

PE

Ambient temperature: Ambient temperature:


~45 °C ~45 °C
-1M -1T -1G
PE

PE
L1

L2

L3

N
L

Max. Cable length: Max. Cable length:


50 m 50 m
Earthing mounting plate 1

=Customer
U: 480V AC U: 120V AC
+L-X
Earthing cabinet 1

120V AC 120V AC
Earthing door 1

f: 60 Hz f: 60 Hz
P: ~33 kW P: ~0,25 kW
Incoming 1 Incoming 2 Earthing screen Control voltage DC
480V AC 120V AC
Icn: 36 kA Icn: 36 kA

Full load current: Full load current:


~77 A ~2,1 A

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 0
Editor GUE/PLE
Customer:
Separator Incoming
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 10
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

480V AC 480V AC
10.9 / L2.2 L2.2 / 20.0
10.9 / L3.2 L3.2 / 20.0
220V AC
L.A / 13.4
N.A / 12.0
220V AC
L.X / 12.0
1

5
-F1 N.X /
0,9...1,25A
EW:0,97A
I> I> I>
2

6
480V AC

480V AC

N/L2
L1
-T1 A F C K -T2
INPUT
400VA 120/230VAC GEA
24VDC/5A power

GND

OFF

ON
ua va PE ub vb
220V AC

220V AC

A
B
OUTPUT

-PE

L+

L+'

PE

M'
M.A / 13.2
-PE
M.K / 28.0
M.R / 14.0

2
-24M
1

-F2
2

C6A
-PE
M.T / 30.0
M.X / 18.0
24V DC
L+.A / 12.7
24V DC
L+.K / 31.0
24V DC
L+.X / 16.0
24V DC
L+.T / 30.0
3

-X1

-PE

-PE
N
L

-M1
M
45/39W 1~
Cabinet fan
PE

Control voltage AC Control voltage DC

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 0
Editor GUE/PLE
Customer:
Separator Control voltage
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 11
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

220V AC 220V AC
11.9 / L.X L.X /
220V AC
1L.X / 13.4
220V AC
1L.A / 20.4

7
-X1

24V DC 24V DC
11.9 / L+.A L+.A / 13.2

11
-K1

12

14
/12.6

29
X11
E2.7
/32.5

=00-K1
Separator
emergency stop

A1
-K1

A2
11.9 / N.A N.A / 13.4
Remove link in case of
an external
8

emergency stop!
(optional) -X1

-X1_W17
.-O
2x1 mm²
21

14
11 /12.8
12
-S01
22

Emergency stop external Emergency stop

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 0
Editor GUE/PLE
Customer:
Separator Emergency stop
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 12
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC 220V AC 220V AC


10.9 / L1 12.9 / L+.A L+.A / 14.0 11.9 / L.A L.A /
220V AC
10.9 / L2 11.9 / M.A M.A / 15.0 12.9 / 1L.X
10.9 / L3

Current measuring separator

=00-K1
4-20mA = 0-50A
/32.4
PEW752I
X11

13
-F1

14
/13.4

11
1

-Q1 -K1
-T1
2

12

14
/13.8 /14.1
*0_9_011
7+
2
S1

Input
8

0-1A
-B1
3

Output
9-
S2

100/1A 0/4-20mA

A1

A1
T1
-F1 M -Q1
T2

A2

A2
12.9 / N.A N.A / 20.4
-PE
Link remove at
connection of an
sludge discharge flap!
1

5
(optional)
-X1 -X2 -X1

-X1_W2 -X1_W13
_-J .-O
4x16 mm² 2x1 mm²
Anti-clockwise rotation
W1
U1

V1

PE

13 14 /13.8 1 2 /13.1
M 21 22 /14.2 3 4 /13.1
10_1_001 3~ 5 6 /13.1
13 14
26,0kW/41,0-43,0A Θ
21 22
T2

T1

33 34 /14.1
43 44 /26.2

Separator PTC-feeler Spare Separator operation


separator

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 13
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
13.3 / L+.A L+.A / 15.0

33

21
-Q1 34 -F1

22
/13.8 /13.4
2

3
X12 X12
E0.0 E0.1
/33.4 /33.4

=00-K1 =00-K1
Separator Separator
operation failure

=00-K1
/33.5
A1.0
X12
32
A1

-K1
A2

11.9 / M.R M.R / 19.0

14
11 /13.8
12

Separator
start/stop

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 14
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
14.9 / L+.A L+.A / 19.0
13.3 / M.A

=00-K1
0-6800 r.p.m.
/33.4
E0.3
X12

-T2 5
4+
6-

24VDC
5+

1+

2-
3

-X2

-X1_W9
.-J
7x1 mm²
/16.1
+JB

-1X10 1 2

+JB-WG101
.-O
2x0,34 mm²
+

10_9_018
SI
-

+ BN = brown
- BU = blue

Speed monitoring device

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator speed measuring
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 15
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K1 =00-K1
4-20mA 4-20mA
/32.4 /32.4
PEW754I PEW756I
X11 X11
=00-K1 =00-K4
6

9
/33.4 /36.5
E0.5 E8.7
X12 X1

9
24V DC 24V DC
11.9 / L+.X L+.X / 23.0

-PE

10

11

12
5

-X2 9

-X1_W9 -WG001
.-J .-O
7x1 mm² 2x1 mm²
/15.1
+JB
L+_1X10 / 17.1
PE
4

-1X10 PE

+JB-WG121
.-J
5x1,5 mm²

+SB
PE_1X20 / 18.6
M_1X20 / 18.5
2

-1X20

+SB-WG201 +SB-WG202 +SB-WG203


.-O .-O .-O
2x0,34 mm² 2x0,34 mm² 3x0,75 mm²
A/Q

13
+
1

13_7_020
11_9_002 I 10_9_014 I 10_9_013
14

PSL/H P SMS P WMS


4-20mA 4-20mA

Clean-oil Sludge room monitoring Water discharge Sludge discharge


discharge pressure flap

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator signals
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 16
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K1
/33.4
E1.7
X12

19
13
-X2

-X1_W5
.-J
7x1 mm²
/18.3
+JB 16.3 / L+_1X10
M_1X10 / 18.3

-1X10 8 11 9 10

+JB-WG104
_CY-O
4x0,75 mm²
SC
1

10_9_020
PCH 1220
+24V DC

0V

-D1

Relay

NAHH separator NAHH separator


vibration monitoring vibration monitoring

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator vibro
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 17
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K1 =00-K1 =00-K1 =00-K1 =00-K1


/33.5 /33.5 /33.5 /33.5 /33.5
A0.0 A0.2 A0.1 A0.4 A0.5
X12 X12 X12 X12 X12
22

24

23

26

27
11.9 / M.X M.X / 22.0

-PE
14

15

16

17

18

19

20

21
-X2

-X1_W5
.-J
7x1 mm²
/17.4
+JB
17.1 / M_1X10

-PE -PE
12

13

15

14

16

18

17

PE
-1X10 PE PE -1X10 PE

+JB-WG122
.-J
4x1,5 mm²

+SB
16.3 / M_1X20
16.3
PE_1X20

11

10
PE

PE
8

9
-1X20 PE PE

-X1_W4 +JB-WG105 +JB-WG106 +SB-WG204 +SB-WG205


.-O .-J .-J .-J .-J
2x1 mm² 3x1,5 mm² 3x1,5 mm² 3x0,75 mm² 3x0,75 mm²
+

PE

PE

PE

PE
+

+
10_7_006 19_7_003/B 19_7_003/A 10_7_010 10_7_011
-

-
-

Feed valve Operating water Displacem- and Circulation valve Water discharge valve
filling water

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator valves
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 18
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
10.9 / 0L+.X 0L+.X / 24.0
24V DC 24V DC
10.9 / 0L+.A 0L+.A / 24.0
24V DC 24V DC
15.9 / L+.A L+.A / 21.0

13

13
-K11 -K12

14

14
/19.3 /19.4

11

22

23
=00-K1
-K10

12

14
/33.5 /19.1 X11 X11
A1.7 E2.0 E2.1
/32.5 /32.5
X12

=00-K1 =00-K1
39

Valve clean-oil discharge


limit switch open Valve clean-oil discharge
limit switch closed
A1

A1

A1

23

23
-K10 -K11 -K12 -K11 -K12
A2

A2

A2

24

24
/19.3 /19.4
10.9 / 0M.R 0M.R / 24.0
10.9 / 0M.X 0M.X / 24.0
14.9 / M.R M.R / 21.0
PE -PE
22

23

24

25

26

27

28

29

30

31

32
-X2 -X2 -X2
0,5A/MT

-X0_W3 -WG021
.-J .-J
7x1 mm² 7x1 mm²
1

3
2

5
4

8
10_7_014
Type RE

6+
3
2

5
4

PE
10_7_014/A 10_7_014/B 10_7_013
ZS ZS
1

7-
Open Closed +HFO2

PE
22

23

24

25

26

27
8106-2011-062
-X2

14 13 14 /19.8 13 14 /19.8
11 /19.5
12 23 24 /19.8 23 24 /19.8
33 34 33 34
43 44 43 44

Valve Valve clean-oil Valve clean-oil Valve Valve Valve clean-oil discharge
clean-oil discharge discharge limit switch open discharge limit switch closed clean-oil discharge clean-oil discharge limit switch open Valve clean-oil discharge
from HFO2 to HFO2 limit switch closed
to HFO2

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator clean-oil discharge
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 19
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

480V AC 220V AC
10.9 / L1.2 12.9 / 1L.A
11.9 / L2.2
11.9 / L3.2

5
-Q1

17
3-12A L1 L2 L3

13

21
A1
110-220V DC/AC -Q1

18
/20.2

14

22
A2
/20.7 /21.1

3-12A
110-220V DC/AC
Control module
LUCA12FU
EW:10,5A

11
-K2

14

12
/21.1

17

97
18

98
/20.7 /21.2
T1 T2 T3
2

A1
-Q1

A2
/20.2

13.9 / N.A
-PE
1

-X1

-X1_W3
_-J
4x2,5 mm²

Clockwise rotation Achtung! 13 14 /21.1


W1
U1

V1

PE

21 22
Vor dem Einschalten der Zulaufpumpe 17 18 /20.7
10_3_001
M den Leistungsschalter auf Nennstrom 97 98 /21.2
6,33kW 3 des Motors einstellen (s. Typenschild des Motors)
10,5A
Attention!
Before switch-on feed pump, adjust the circuit breaker
to nominal current of the motor (look at motor label)
Feed pump Feed pump

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 11
Editor GUE/PLE
Customer:
Separator Feed pump
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 20
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
19.9 / L+.A L+.A / 22.0

13

97
-Q1 -Q1
14

98
/20.2 /20.3
12

13
X12 X12
E1.0 E1.1
/33.4 /33.4

=00-K1 =00-K1
Feed pump Feed pump
operation failure

=00-K1
/33.5
A1.1
X12
33
A1

-K2
A2

19.6 / M.R M.R / 26.0

14
11 /20.7
12

Feed pump
start / stop

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 11
Editor GUE/PLE
Customer:
Separator Feed pump
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 21
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
21.9 / L+.A L+.A / 25.0
18.9 / M.X M.X / 27.0

Control valve heating Product Min / max


medium positioner temperature control temperature monitoring
=00-K1 =00-K1 =00-K1
4-20mA 4-20mA = 0-120°C 4-20mA = 0-120°C
/32.4 /32.4 /32.4 /32.4
PAW754I PEW758I PEW760+ PEW760-
X11 X11 X11 X11

12

14

15
19
-SC -SC

1
-T1
Output
0/4-20mA

PT100

-SC

4
-SC
SC

SC
7

4
-X2 -X2

-X1_W14 -X1_W12
.CY-O .CY-O
2x1 mm² 4x1 mm²
/22.3

10_9_008
1

3
Θ Θ
+

PT100 PT100
10_7_012
2

4
SIPART PS2
4-20mA

Control valve heating medium Product Min / max


positioner temperature control temperature monitoring

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 11
Editor GUE/PLE
Customer:
Separator Product temperature control
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 22
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K2
/34.3
PEW256I
X1
2

24V DC 24V DC
16.9 / L+.X L+.X / 27.0
5

-X2

-WG004
.-O
2x1 mm²
1

10_9_009 I
FI P
4-20mA

FI flow measuring

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 11
Editor GUE/PLE
Customer:
Separator FI flow measuring
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 23
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC
19.9 / 0L+.X
19.9 / 0L+.A
10.9 / 0L+.T

23

13

13

23
M 0 A
-S1 -S2 -K1

14

24
/24.1
24

14
11

13

33
-K3 -K1 -K1
12

14

14

34
/24.5 /24.1 /24.1
11

-K2
12

14

/24.3
A1

A1

A1

A1
x1

-K1 -P1 -K2 -K3 -K4


A2

x2

A2

A2

A2
RD
19.6 / 0M.R
19.6 / 0M.X
10.9 / 0M.T

11

10
1

9
-X2 -X2
0,5A/MT

-X0_W7 -X0_W6 -X0_W5 -X0_W4


.-O .-O .-O .-O
2x1 mm² 2x1 mm² 2x1 mm² 2x1 mm²

+
4

2
90_9_003 90_9_002 90_9_001 98_7_002
3

1
LSL LSH LSHH

-
13 14 /24.2 14 14 13 14 /25.1
11 /24.1 11 /24.1
23 24 /24.3 12 12 23 24 /25.1
33 34 /24.9 24 33 34
21 /26.8
43 44 22 43 44

Valve pneumatic sludge Sludge pump LSL sludge tank LSH sludge tank LSHH sludge tank Valve pneumatic sludge
pump operation level min. level max. level max. / max. pump

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 16
Editor GUE/PLE
Customer:
Separator Sludge pump
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 24
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
22.9 / L+.A L+.A / 28.0

-K4 13
14
/24.6
9

X12
E0.7
/33.4

=00-K1
LSHH sludge tank
23

-K4
24

/24.6

-PE
12

13

-X2

-WG010
.-J
3x1 mm²

+HFO2
PE
1

8106-2011-062
-X2

LSHH sludge tank


to HFO2

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 16
Editor GUE/PLE
Customer:
Separator Sludge pump
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 25
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K1 =00-K1 =00-K1 =00-K1 =00-K4 =00-K4


/33.5 /33.5 /33.5 /33.5 /36.5 /36.5
A0.7 A1.3 A1.4 A1.5 A8.0 A8.1
X12 X12 X12 X12 X1 X1
29

35

36

37

12

13
A1

A1

A1

A1

A1

A1
-K1 -K2 -K3 -K4 -K5 -K6
A2

A2

A2

A2

A2

A2
21.9 / M.R

14 14 14 14 14 14
11 11 /26.2 11 /26.4 11 /26.5 11 /26.6 11 /26.7
12 12 12 12 12 12
24
21 /26.0
22
43

12

14

12

14

12

14

12

14

12

14

22

24
22

24

12

14

=01-Q1 -K2 -K3 -K4 -K5 -K6 =16-K2


-K1 =0-Q1
44

11

11

11

11

11

21
/13.8 /26.3 /26.4 /26.5 /26.6 /26.7 /24.3
21

11

/26.1 /10.1
PE

10

11

12

13

14

15

16

17
1

3
4

9
-X2

-X1_W19
.-J
18x1,5 mm²

=+DCS

PE
-X -X -X -X -X -X -X -X

Common failure Separator Sludge tank TAH TAL Local / remote PAL clean-oil Sludge tank
operation Level high / high Alarm HFO temperature HFO temperature status discharge pressure Low alarm

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 100
Editor GUE/PLE
Customer:
Separator Signal exchange
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 26
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K4 =00-K4 =00-K4 =00-K3 =00-K3


4-20mA 4-20mA
/36.5 /36.5 /36.5 /35.5 /35.5
E8.0 E8.1 E8.2 PAW272 PAW274
X1 X1 X1 X1 X1
2

7
-SC -SC

=0-SC =0-SC

24V DC 24V DC
23.9 / L+.X L+.X /
22.9 / M.X M.X /
-SC
PE

SC
18

19

20

21

22

23

24

25

26

27
-X2

-X1_W20 -X1_W18
.-J .CY-O
7x1,5 mm² 4x1,5 mm²
/27.8

=+DCS
PE

-X -X -X -X -X

-K -K -K

HFO daily tank level HFO daily tank level Remote start / stop Clean-oil HFO temperature
Low control High control NO for stop, NC for start discharge pressure
Change to daily tank Change to settling tank

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 100
Editor GUE/PLE
Customer:
Separator Signal exchange
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 27
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K1 -K1 -K1 -K1 -K1


/33.4 /32.4 /32.4 /32.4 /32.4
E1.6 PEW752-
- PEW754- PEW756-
- PEW758-
X12 X11 X11 X11 X11
18

10

13
24V DC
25.9 / L+.A
11.9 / M.K M.K / 29.0

Spare Earth analog Earth analog Earth analog Earth analog

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 28
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K2 -K2 -K2 -K2 -K2 -K2 -K2 -K2 -K3


/34.3 /34.3 /34.3 /34.3 /34.5 /34.5 /34.5 /34.5
PEW256M- PEW258M- PEW260M- PEW262M- PEW264M- PEW266M- PEW268M- PEW270M-
/35.5 /35.5
X1 X1 X1 X1 X1 X1 X1 X1

Mana
6

Mana
10
5

10

15

20

25

30

35

40
28.9 / M.K M.K / 31.0

Earth analog Earth analog Earth analog Earth analog Earth analog Earth analog Earth analog Earth analog Earth analog Earth analog

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 29
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-P1
Button Designation Symbol

Westfalia Separator

OP 177B

ACK

DP/MPI/PPI 1F1B USB


1 2 3 4
ON
POWER DC OFF ● ● ● ●
SC

SC
A

A
B

B
24V

0V

PE

24V DC
11.9 / L+.T MPI_A / 31.0
11.9 / M.T MPI_B / 31.0
-PE

Process display

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator Process display OP 177B
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 30
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K1 CPU 313C


-K2 -K3 -K4
2AO
8AI 8DI/8DO
0005-4050-720 6ES7331-1KF02-0AB0 0005-4281-010 0005-4050-730
6ES7313-5BF03-0AB0 6ES7331-1KF02-0AB0 6ES7332-5HB01-0AB0 6ES7323-1BH01-0AA0
Rack: 1 Rack: 1 Rack: 1
Slot: 4 Slot: 5 Slot: 6
SF GEA
BF Rack: 1
Slot: 1-3
DC5V 0 0 0 0 0
FRCE X11 1 1
X12 1 1
X1 1
RUN
2 2 2 2 2
STOP
3 3 3 3 3
PUSH
4 4 4 4 4
RUN
5 5 5 5 5
STOP
6 6 6 6 6

PEW270M-
PAW754U
PEW758V
MRES

PAW274
7 7 7 7 7

A1.7

A8.7
E2.7

E1.7
IN IN OUT IN IN

-
-
-
-

-
-
E2.0

E0.0
A0.0
PEW752V
PAW752U

PAW272

E8.0
PEW256I
L+ 0 0 0 0
1 1 1 1
M
2 2 2 2
3 3 3 3
4 4 4 4
5 5 5 5
6 6 6 6
7 7 7 7

X1 MPI
A
30.9 / MPI_A
B
30.9 / MPI_B
SC

A
Mana /32.4

B
1L+ /33.4

2L+ /33.5

3L+ /33.5

1L+ /35.5

2L+ /36.5
4M /32.5

1M /33.4

2M /33.5

3M /33.5

1M /35.5

1M /36.5

2M /36.5
SC

DC 24V
L+

X11:20

X11:30

X12:1

X12:20

X12:21

X12:30

X12:31

X12:40

X1:1

X1:20

X1:10

X1:11

X1:20
24V DC
11.9 / L+.K
29.9 / M.K

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC power supply
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 31
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K1

X11:1 X11:21

X11:2 X11:22
PEW752V E2.0 /19.8 =01-K11:14 Valve clean-oil discharge limit switch open

X11:3 X11:23
Current measuring separator =01-T1:8 /13.3 PEW752I E2.1 /19.8 =01-K12:14 Valve clean-oil discharge limit switch closed

X11:4 X11:24
Earth analog /28.2 - E2.2

X11:5 X11:25
PEW754V E2.3

X11:6 X11:26
Clean-oil discharge pressure =01-X2:6 /16.1 PEW754I E2.4

X11:7 X11:27
Earth analog /28.3 E2.5

X11:8 X11:28
PEW756V E2.6

X11:9 X11:29
Sludge room monitoring =01-X2:8 /16.2 PEW756I E2.7 /12.8 =0-K1:14 Separator emergency stop

X11:10
Earth analog /28.4 - X11:30
4M /31.3 0V
X11:11
PEW758V V X11:31

X11:12
Product temperature control =11-T1:1 /22.5 PEW758I A
X11:32
X11:13
Earth analog /28.4
X11:33
X11:14
Min / max temperature monitoring =11-X2:3 /22.6 PEW760+
X11:34
PT100
X11:15
Min / max temperature monitoring /22.6 PEW760-
X11:35

X11:16 X11:36
PAW752U

X11:17 X11:37
PAW752I

X11:18 X11:38
PAW754U

X11:19 X11:39
Control valve heating medium positioner =11-X2:7 /22.3 PAW754I

X11:20 X11:40
Mana /31.3 Mana

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 32
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K1

X12:1 X12:21
24V /31.3 1L+ 2L+ /31.3 24V

X12:2 X12:22
Separator operation =01-Q1:34 /14.1 E0.0 A0.0 /18.1 =01-X2:14 Feed valve

X12:3 X12:23
Separator failure =01-F1:22 /14.2 E0.1 A0.1 /18.4 =01-X2:17 Displacem- and filling water

X12:4 X12:24
E0.2 A0.2 /18.3 =01-X2:16 Operating water

X12:5 X12:25
Speed monitoring device =01-T2:4+ /15.2 E0.3 A0.3

X12:6 X12:26
E0.4 A0.4 /18.5 =01-X2:19 Circulation valve

X12:7 X12:27
Water discharge =01-X2:10 /16.3 E0.5 A0.5 /18.6 =01-X2:20 Water discharge valve

X12:8 X12:28
E0.6 A0.6

X12:9 X12:29
LSHH sludge tank =16-K4:14 /25.1 E0.7 A0.7 /26.1 =100-K1:A1 Common failure

X12:10 X12:30
2M /31.3 0V

X12:11 X12:31
3L+ /31.4 24V

X12:12 X12:32
Feed pump operation =11-Q1:14 /21.1 E1.0 A1.0 /14.1 =01-K1:A1 Separator start/stop

X12:13 X12:33
Feed pump failure =11-Q1:98 /21.2 E1.1 A1.1 /21.1 =11-K2:A1 Feed pump start / stop

X12:14 X12:34
E1.2 A1.2

X12:15 X12:35
E1.3 A1.3 /26.3 =100-K2:A1 Sludge tank Level high / high Alarm

X12:16 X12:36
E1.4 A1.4 /26.4 =100-K3:A1 TAH HFO temperature

X12:17 X12:37
E1.5 A1.5 /26.5 =100-K4:A1 TAL HFO temperature

X12:18 X12:38
Spare =16-K4:13 /28.1 E1.6 A1.6

X12:19 X12:39
NAHH separator vibration monitoring =01-X2:13 /17.4 E1.7 A1.7 /19.1 =01-K10:A1 Valve clean-oil discharge

X12:20 X12:40
0V /31.3 1M 3M /31.4 0V

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 33
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K2

X1:1 X1:21
PEW256V PEW264V

X1:2 X1:22
FI flow measuring =11-10_9_009:2 /23.1 PEW256I V V PEW264I

X1:3 X1:23
PEW256S- A A PEW264S-

X1:4 X1:24
PEW256M+ PEW264M+

X1:5 X1:25
Earth analog /29.1 PEW256M- PEW264M- /29.4 Earth analog

X1:6 X1:26
PEW258V PEW266V

X1:7 X1:27
PEW258I V V PEW266I

X1:8 X1:28
PEW258S- A A PEW266S-

X1:9 X1:29
PEW258M+ PEW266M+

X1:10 X1:30
Earth analog /29.2 PEW258M- PEW266M- /29.5 Earth analog

X1:11 X1:31
PEW260V PEW268V

X1:12 X1:32
PEW260I V V PEW268I

X1:13 X1:33
PEW260S- A A PEW268S-

X1:14 X1:34
PEW260M+ PEW268M+

X1:15 X1:35
Earth analog /29.2 PEW260M- PEW268M- /29.6 Earth analog

X1:16 X1:36
PEW262V PEW270V

X1:17 X1:37
PEW262I V V PEW270I

X1:18 X1:38
PEW262S- A A PEW270S-

X1:19 X1:39
PEW262M+ PEW270M+

X1:20 X1:40
Earth analog /29.3 PEW262M- PEW270M- /29.7 Earth analog

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 34
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K3
2AO

X1:1
1L+ /31.5 24V

X1:2

X1:3
PAW272 /27.6 =100-X2:24 Clean-oil discharge pressure

X1:4
S+

X1:5
S-

X1:6
Mana /29.8 Earth analog

X1:7
PAW274 /27.8 =100-X2:26 HFO temperature

X1:8
S+

X1:9
S-

X1:10
Mana /29.8 Earth analog

X1:11

X1:12

X1:13

X1:14

X1:15

X1:16

X1:17

X1:18

X1:19

X1:20
1M /31.6 0V

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 35
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K4

X1:1
1L+

X1:2
E8.0 /27.1 =100-X2:19 HFO daily tank level Low control Change to daily tank

X1:3
E8.1 /27.2 =100-X2:21 HFO daily tank level High control Change to settling tank

X1:4
E8.2 /27.4 =100-X2:23 Remote start / stop NO for stop, NC for start

X1:5
E8.3

X1:6
E8.4

X1:7
E8.5

X1:8
E8.6

X1:9
E8.7 /16.6 =01-13_7_020:14 Sludge discharge flap

X1:10
1M /31.6 0V

X1:11
2L+ /31.7 +24V

X1:12
A8.0 /26.6 =100-K5:A1 Local / remote status

X1:13
A8.1 /26.7 =100-K6:A1 PAL clean-oil discharge pressure

X1:14
A8.2

X1:15
A8.3

X1:16
A8.4

X1:17
A8.5

X1:18
A8.6

X1:19
A8.7

X1:20
2M /31.7 0V

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 36
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EFS 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

600 mm
560 mm 300 mm

-Cabinet ø 8mm -Mountingplate


HFO 1

0-T01
0-T2
Filter

=00-P1

100-K1
16-K2

01-K11

01-K12

16K1
16K4
01-K10

100-K2
100-K3
100-K4
100-K5
100-K6
16-K3
01-K1
11-K2
0-K1
=16-S1
=16-P1 =16-S2

0-F01

0-F1

01-F1
01-T1
0-F2

01-T2
0-T1

11-T2
1200 mm

1160 mm

0-024M

01-B1
0-24M
0-Q1

11-Q1
100-X2
01-Q1
=0-Q1
I

O
=0-M1

01-X1

11-X1
01-X2

11-X2

16-X2
0-X1
=00-P1 Process display
=0-M1 Filter / fan
=0-Q1 Isolator Cable glands Size
=16-P1 Sludge pump operation
14x M20 incl. 3x spare 8 - 13mm
=16-S1 Sludge pump manual-0-automatic
11x M25 incl. 3x spare 11 - 17mm
=16-S2 Lamp test
3x M32 incl. 1x spare 15 - 21mm
3x M40 incl. 1x spare 19 - 28mm

Scale 1:7,5 mm Weight: ca. 80kg HFO 1


Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Arrangement drawing control cabinet
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 37
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & ELU 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Control unit E40

Bestell-nr.
0005-4050-700
Westfalia Separator AG
order no.
Programm-Nr.
8106-1E40-768
program-no.

Tiefe: __mm

215
depth:

Ausschnittmass: 228x195mm
cutout dimension:

Gewicht: _,__kg
weight:
ACK

245

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator E40
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 38
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & ELU 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

&EFS/11.6

&EFS/11.6

&EFS/11.6
Cross reference

0V

PE
=00-P1
Target internal

-PE
-T2

Bridges
=0+-24M

Terminal number
1

2
Control voltage DC

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =0+-24M
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 39
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMA 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

&EFS/10.6

&EFS/10.6

&EFS/10.6
Cross reference

x2

PE
=16-P1
Target internal -T01

-PE
Bridges
=0+-024M

Terminal number
1

2
Control voltage DC before isolator

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =0+-024M
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 40
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMA 62 Bl./Sh.
=0+-PE

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
=Customer+L-X

Editor
&EFS/10.1

Tested
Incoming 1 480V AC PE

PE
-X1_W1

PE
_-J 4x25 mm²

PE
Incoming 2 120V AC PE &EFS/10.2

PE
1

-W001

PE
_-J 3x1,5 mm²

GUE/PLE
19.07.2012

07.09.2012/KA
-SC
Earthing screen PE &EFS/10.3

SC

SC
-1M

Kunde:
&EFS/10.4

Project:
Projekt:
Earthing mounting plate 1 PE PE

PE

Customer:
-PE

GN/YE
2

-1T
Earthing door 1 PE PE &EFS/10.4

PE
-PE

GN/YE

Esmeraldas II
-1G
Earthing cabinet 1 PE PE &EFS/10.5

PE
-PE

GN/YE

PDV Power Technology


-PE
Control voltage DC before isolator PE &EFS/10.6
-T01 PE
3

Control voltage AC PE &EFS/11.1

Control voltage DC before isolator PE &EFS/10.6


-024M 2
Control voltage AC PE &EFS/11.2
-X1 6

-M1
= PE &EFS/11.2
PE

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
GN/YE
4

Separator
L

M
1~

GEA Westfalia
PE N
N

-PE
Control voltage DC PE &EFS/11.6

= PE &EFS/11.6
-24M 2

Benennung/Description:
5

=01-10_7_014
Valve clean-oil discharge PE &EFS/19.5
8

=01-X0_W3
PE

-PE
.-J 7x1 mm²

Terminal connecting plan =0+-PE


=01-10_1_001
Separator PE &EFS/13.2
PE

=01-X1_W2
PE

_-J 4x16 mm²


U1

T2 U1
V1

V1
Θ
M
6

3~

T1 W1
W1

PE
T2
T1

=01+HFO2-X2
Valve clean-oil discharge limit switch closed to HFO2 PE &EFS/19.9
PE

Sprache:
PE

=01-WG021
PE

Language:
-PE
.-J 7x1 mm²
7

=16+HFO2-X2
LSHH sludge tank to HFO2 PE &EFS/25.1
PE

PE

=16-WG010
PE

-PE
.-J 3x1 mm²
en

=01+JB-1X10
Water discharge PE &EFS/16.3
PE =01-X1_W9
PE

.-J 7x1 mm²


&EFS/18.7
PE

Water discharge valve PE


Drawing No.:
PE:PE PE:PE

=01-X1_W5
Zeichnungs Nr.:
PE

-PE
.-J 7x1 mm²
8

=11-10_3_001
Feed pump PE &EFS/20.1
PE

HFO Separator Double Unit (HFO 1)

U1 =11-X1_W3
PE

-PE
_-J 4x2,5 mm²
U1

V1
M

W1
V1

8106-2011-061

PE
As built +
Rev.05 =
W1

DCC
& EMA
9

Bl./Sh.
62 Bl./Sh.
41
0 1 2 3 4 5 6 7 8 9

&EFS/26.9
&EFS/27.4
Cross reference

Target internal

Bridges
=0+-PE

Terminal number
PE

PE
=100-X1_W20

=100-X1_W19
.-J 18x1,5 mm²
.-J 7x1,5 mm²

PE PE
PE PE

PE
+DCS-X
Remote start / stop NO for stop, NC for start

Sludge tank Low alarm

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =0+-PE
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 42
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMA 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

&EFS/10.3

&EFS/22.6

&EFS/22.3

&EFS/22.4

&EFS/22.7
&EFS/27.8

&EFS/27.8
&EFS/27.7
Cross reference

Target internal -SC

-SC

-SC

-SC

-SC

-SC
Bridges
=0+-SC

SC

SC

SC

SC

SC

SC

SC

SC
Terminal number

PE SC SC SC

PE SC SC SC
-PE

=11-X2

=100-X2

=11-X2

-SC
Control valve heating medium positioner

Min / max temperature monitoring


Product temperature control

Clean-oil discharge pressure


HFO temperature

HFO temperature
Earthing screen

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =0+-SC
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 43
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMA 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

&EFS/10.2

&EFS/10.2

&EFS/11.1

&EFS/11.1

&EFS/11.1

&EFS/11.2

&EFS/12.1

&EFS/12.1

&EFS/12.1
Cross reference

vb

4
=01-X1
Target internal -F01

-F01

-F2

-T1
Bridges
=0+-X1

Terminal number
1

9
_-J 3x1,5 mm²

.-O 2x1 mm²


-X1_W17
-W001

1 2 RD_U RDWHU GN/YE 1 2


L N L N PE PE 21 22
N
L

21

M
1~
PE
PE

L
22
=Customer+L-X

-M1

-PE

-S01
Emergency stop external
Control voltage AC

Control voltage AC
Spare

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =0+-X1
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 44
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMA 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

&EFS/10.1

&EFS/10.1

&EFS/10.1
Cross reference

6
Target internal -Q1

-Q1

-Q1
Bridges
=0+-XQ1

Terminal number
2

6
_-J 4x25 mm²
-X1_W1

1 2 3
L1 L2 L3

L1
=Customer+L-X
Incoming 1 480V AC

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =0+-XQ1
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 45
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMA 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

&EFS/13.1

&EFS/13.1

&EFS/13.1

&EFS/13.8
&EFS/13.7
Cross reference

13
Target internal

=0-X1
-Q1

-Q1

-Q1

-F1
Bridges
=01+-X1

Terminal number
1

5
_-J 4x16 mm²
-X1_W2

1 2 3
U1 V1 W1 T2 T1 PE
W1
U1

V1

PE

M
3~
Θ
T2

T1
-10_1_001
Separator

Spare
=

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =01+-X1
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 46
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMA 62 Bl./Sh.
=01+-X2

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
-10_1_001

Editor
&EFS/13.3

Tested
PTC-feeler separator 1

T1
1
-F1 T1
-X1_W13 &EFS/13.3
= .-O 2x1 mm² 2

T2
1

2
T2 U1
-F1 T2

GUE/PLE
19.07.2012
U1
V1

Θ
M
3~

07.09.2012/KA
T1 W1

V1
PE

W1

Kunde:

Project:
Projekt:
PE

Customer:
2

+JB-1X10
Speed monitoring device 3 &EFS/15.2

1
1
-T2 1+
= 4 &EFS/15.2

Esmeraldas II
2
-T2 2-
Clean-oil discharge pressure 5 &EFS/16.1

4
3
=0-T2 L+
&EFS/16.1

PDV Power Technology


= 6

3
4
=00-K1 X11:6

1
-X1_W9 &EFS/16.2
Sludge room monitoring .-J 7x1 mm² 7
3

= 8 &EFS/16.2
6
5

=00-K1 X11:9
Spare 9 &EFS/16.3

Water discharge 10 &EFS/16.3


7
6

=00-K1 X12:7

-13_7_020
Sludge discharge flap 11 &EFS/16.5
13
1

-13_7_020 13
14 13

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
-WG001 &EFS/16.6
4

Separator
= .-O 2x1 mm² 12
14
2

GEA Westfalia
-13_7_020 14

+JB-1X10
NAHH separator vibration monitoring 13 &EFS/17.4
10
1

10

-X1_W5 =00-K1 X12:19


.-J 7x1 mm²

-10_7_006 - +
Feed valve 14 &EFS/18.1
+
1

=00-K1 X12:22
-X1_W4 &EFS/18.1

Benennung/Description:
-

= .-O 2x1 mm² 15


5

=0-24M 1

+JB-1X10
Operating water 16 &EFS/18.3
12
2

=00-K1 X12:24

Terminal connecting plan =01+-X2


Displacem- and filling water 17 &EFS/18.4
15
3

=00-K1 X12:23
= 18 &EFS/18.4
12

-X1_W5 &EFS/18.5
Circulation valve .-J 7x1 mm² 19
16
4

=00-K1 X12:26
6

Water discharge valve 20 &EFS/18.6


18
5

=00-K1 X12:27
= 21 &EFS/18.7
17
6

=11-X2 8

-10_7_014
Valve clean-oil discharge 22 &EFS/19.2
1
1

=0-T01 L+
Valve clean-oil discharge limit switch open 23 &EFS/19.2
2

Sprache:
2

Language:
-K11 A1
7

Valve clean-oil discharge limit switch closed 24 &EFS/19.4


4
3

-X0_W3 -K12 A1
.-J 7x1 mm²
Valve clean-oil discharge 25 &EFS/19.5
6
4

-K10 14
en

= 26 &EFS/19.5
7
5

=0-024M 1

+HFO2-X2
Valve clean-oil discharge from HFO2 27 &EFS/19.7
Drawing No.:
22
1

Zeichnungs Nr.:

-K10 14
&EFS/19.7
8

= 28
23
2

=16-X2 2
Valve clean-oil discharge limit switch open 29 &EFS/19.8
24

HFO Separator Double Unit (HFO 1)


3

-K11 24
22

-WG021 &EFS/19.8
Valve clean-oil discharge limit switch closed .-J 7x1 mm² 30
25
4

-K12 24
Valve clean-oil discharge limit switch closed to HFO2 31 &EFS/19.9
26
5

8106-2011-061

-K12 23
As built +
Rev.05 =

= 32 &EFS/19.9
27

DCC
6

& EMA
9

Bl./Sh.
62 Bl./Sh.
47
=01+JB-1X10

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
-19_7_003/B

Editor
&EFS/18.3

Tested
Operating water PE PE

PE
-WG105

PE
-PE
.-J 3x1,5 mm²
1

+SB-1X20

GUE/PLE
PE &EFS/16.3
Water discharge PE

19.07.2012
PE:PE
-WG121

PE
=0-PE PE

PE
.-J 5x1,5 mm²

07.09.2012/KA
-10_9_018
Speed monitoring device - + 1 &EFS/15.2

+
-X2 3

BN

Kunde:
-WG101 &EFS/15.2

Project:
Projekt:
-
= .-O 2x0,34 mm² 2

Customer:
-X2 4

BU
2

+SB-1X20
Clean-oil discharge pressure 3 &EFS/16.1

1
1
-X2 6
= 4 &EFS/16.1

Esmeraldas II
2
-X2 5
= 5 &EFS/16.1

1
-WG121
.-J 5x1,5 mm²
&EFS/16.2

PDV Power Technology


Sludge room monitoring 6

4
3
-X2 8
Water discharge 7 &EFS/16.3

5
4
-X2 10
3

-10_9_020
NAHH separator vibration monitoring 8 &EFS/17.1
1
BN

= 9 &EFS/17.3
3
BK

-WG104 &EFS/17.4
= 10
4

_CY-O 4x0,75 mm²


-X2 13
WH

= 11 &EFS/17.1
2
BU

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
4

Separator
GEA Westfalia
-19_7_003/B
Operating water - + 12 &EFS/18.3
+

-X2 16
BN

-WG105 &EFS/18.3
-

= .-J 3x1,5 mm² 13


BU

-19_7_003/A
- + &EFS/18.4
-

Displacem- and filling water 14


BU

-WG106 &EFS/18.4

Benennung/Description:
= 15
+

.-J 3x1,5 mm²


5

-X2 17
BN

+SB-1X20
Circulation valve 16 &EFS/18.5
8
1

-X2 19
Water discharge valve 17 &EFS/18.7
10
2

-X2 21

Terminal connecting plan =01+JB-1X10


8

-WG122 &EFS/18.6
= .-J 4x1,5 mm² 18
11
3

-X2 20
= PE &EFS/18.7
PE:PE
PE

=0-PE PE
6

-19_7_003/A
Displacem- and filling water PE PE &EFS/18.4
PE

-WG106
PE

-PE
.-J 3x1,5 mm²

Sprache:
Language:
7

en Drawing No.:
Zeichnungs Nr.:
8

HFO Separator Double Unit (HFO 1)

8106-2011-061
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
62 Bl./Sh.
48
=01+SB-1X20

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
-11_9_002

I
1

Editor
&EFS/16.1

Tested
Clean-oil discharge pressure 1

2
+JB-1X10 3

WH
2
-WG201 &EFS/16.1
= 2

1
.-O 2x0,34 mm²
1

+JB-1X10 4

BK

GUE/PLE
19.07.2012

07.09.2012/KA
-10_9_014

I
1 &EFS/16.2
Sludge room monitoring 3

1
BK
2
-WG202 &EFS/16.2
= 4

2
.-O 2x0,34 mm²
+JB-1X10 6

P
WH

Kunde:

Project:
Projekt:
Customer:
-10_9_013
Water discharge 5 &EFS/16.3
+

A/Q
+JB-1X10 7
2

BK
= A/Q 6 &EFS/16.3

+
-WG203

BN
.-O 3x0,75 mm²
- &EFS/16.3

-
= 7

Esmeraldas II
GY
-10_7_010
- + &EFS/18.5

PDV Power Technology


Circulation valve 8

+
+JB-1X10 16

BN
-WG204 &EFS/18.5

-
= .-J 3x0,75 mm² 9

BU
3

-10_7_011
- + &EFS/18.7
-

Water discharge valve 10


+JB-1X10 17
BU

-WG205 &EFS/18.6
= 11
+

.-J 3x0,75 mm²


+JB-1X10 18
BN

-10_7_010
Circulation valve PE PE &EFS/18.6
PE

-WG204
PE

+JB-1X10 PE
.-J 3x0,75 mm²

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
4

Separator
GEA Westfalia
-10_7_011
Water discharge valve PE PE &EFS/18.7
PE

-WG205
PE

+JB-1X10 PE
.-J 3x0,75 mm²

Benennung/Description:
5

Terminal connecting plan =01+SB-1X20


6

Sprache:
Language:
7

en Drawing No.:
Zeichnungs Nr.:
8

HFO Separator Double Unit (HFO 1)

8106-2011-061
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
62 Bl./Sh.
49
0 1 2 3 4 5 6 7 8 9

&EFS/20.1

&EFS/20.1

&EFS/20.1
Cross reference

6
Target internal -Q1

-Q1

-Q1
Bridges
=11+-X1

Terminal number
1

3
_-J 4x2,5 mm²
-X1_W3

1 2 3
U1 V1 W1 PE
W1
U1

V1

PE

M
3
-10_3_001
Feed pump

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =11+-X1
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 50
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMA 62 Bl./Sh.
=11+-X2

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
-10_9_008

Editor
&EFS/22.5

Tested
Product temperature control 1

1
1
-T1 3
= 2 &EFS/22.5

Θ
1

2
2 1 -T1 4

GUE/PLE
-X1_W12 &EFS/22.6
Min / max temperature monitoring 3

3
.CY-O 4x1 mm²

19.07.2012
3
=00-K1 X11:14

07.09.2012/KA
= 4 &EFS/22.6

4
4
=00-K1 X11:15

-X1_W14

Kunde:
&EFS/22.4

Project:
Projekt:
Control valve heating medium positioner SC

SC

Customer:
-X1_W14 =0-SC SC

SC
.CY-O 2x1 mm²
2

-X1_W12
Min / max temperature monitoring SC &EFS/22.7

SC
-X1_W12 =0-SC SC

SC
.CY-O 4x1 mm²

Esmeraldas II
-10_9_009

I
1 &EFS/23.1
FI flow measuring 5

1
1
=01-X2 11
-WG004 &EFS/23.1

PDV Power Technology


= 2 6

2
.-O 2x1 mm²

2
=00-K2 X1:2

P
3

-10_7_012 +
Control valve heating medium positioner 7 &EFS/22.3
+
1

=00-K1 X11:19
-
-X1_W14 &EFS/22.3
-

= .CY-O 2x1 mm² 8


2

=01-X2 21

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
4

Separator
GEA Westfalia Benennung/Description:
5

Terminal connecting plan =11+-X2


6

Sprache:
Language:
7

en Drawing No.:
Zeichnungs Nr.:
8

HFO Separator Double Unit (HFO 1)

8106-2011-061
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
62 Bl./Sh.
51
=16+-X2

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
-90_9_003

Editor
&EFS/24.4

Tested
LSL sludge tank level min. 1

4
1
-K2 A1
3 4 -X0_W7 &EFS/24.4
= 2

3
.-O 2x1 mm²
1

2
=01-X2 28

GUE/PLE
= 3 &EFS/24.4

19.07.2012
=01-X2 26

07.09.2012/KA
LSH sludge tank level max. 4 &EFS/24.6

-90_9_002
= 5 &EFS/24.5

4
1
-K3 A1

Kunde:
3 4 -X0_W6 &EFS/24.6

Project:
Projekt:
= 6

3
.-O 2x1 mm²

Customer:
2

-90_9_001
LSHH sludge tank level max. / max. 7 &EFS/24.7

1
1
1 2 -X0_W5 &EFS/24.7
= 8

Esmeraldas II
.-O 2x1 mm²

2
-K4 A1
= 9 &EFS/24.8

-98_7_002 - + &EFS/24.9

PDV Power Technology


-
Valve pneumatic sludge pump 10

1
-X0_W4
.-O 2x1 mm²

+
3

+HFO2-X2
LSHH sludge tank 12 &EFS/25.1
1

1
1

-WG010 -K4 24
.-J 3x1 mm²

-98_7_002 - +
Valve pneumatic sludge pump 11 &EFS/24.9
+
2

-X0_W4 -K1 34
.-O 2x1 mm²
-

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
4

Separator
GEA Westfalia
+HFO2-X2
LSHH sludge tank to HFO2 13 &EFS/25.1
2

2
2

-WG010 -K4 23
.-J 3x1 mm²

Benennung/Description:
5

Terminal connecting plan =16+-X2


6

Sprache:
Language:
7

en Drawing No.:
Zeichnungs Nr.:
8

HFO Separator Double Unit (HFO 1)

8106-2011-061
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
62 Bl./Sh.
52
=100+-X2

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
+DCS-X

Editor
&EFS/26.1

Tested
Common failure 1

1
-K1 21
= 2 &EFS/26.1
1

2
-K1 24

GUE/PLE
Separator operation 3 &EFS/26.2

19.07.2012
3
=01-Q1 44

07.09.2012/KA
= 4 &EFS/26.2

4
=01-Q1 43
Sludge tank Level high / high Alarm 5 &EFS/26.3

5
-K2 11

Kunde:
&EFS/26.3

Project:
Projekt:
= 6

Customer:
-K2 14
TAH HFO temperature 7 &EFS/26.4

7
-K3 11
2

= 8 &EFS/26.4

8
-K3 14
TAL HFO temperature 9 &EFS/26.5

Esmeraldas II
9
-X1_W19 -K4 11
.-J 18x1,5 mm²
= 10 &EFS/26.5

10
-K4 14
&EFS/26.6

PDV Power Technology


Local / remote status 11

11
-K5 11
= 12 &EFS/26.6

12
-K5 14
3

PAL clean-oil discharge pressure


13
13 &EFS/26.7
-K6 11
= 14 &EFS/26.8
14

-K6 14
Sludge tank Low alarm 15 &EFS/26.9
15

=16-K2 21
= 16 &EFS/26.9
16

=16-K2 24
= 17 &EFS/26.9
17

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
&EFS/27.1
4

Separator
HFO daily tank level Low control Change to daily tank 18
1

GEA Westfalia
=11-X2 5
= 19 &EFS/27.1
2

=00-K4 X1:2
HFO daily tank level High control Change to settling tank 20 &EFS/27.2
3

-X1_W20 &EFS/27.2
= .-J 7x1,5 mm² 21
4

=00-K4 X1:3
Remote start / stop NO for stop, NC for start 22 &EFS/27.4
5

&EFS/27.4

Benennung/Description:
= 23
5

=00-K4 X1:4
Clean-oil discharge pressure 24 &EFS/27.6
1

=00-K3 X1:3
= 25 &EFS/27.6
2

=11-X2 8
-X1_W18

Terminal connecting plan =100+-X2


HFO temperature 26 &EFS/27.8
.CY-O 4x1,5 mm²
3

=00-K3 X1:7
= 27 &EFS/27.8
4

= SC &EFS/27.8
=0-SC SC
6

Sprache:
Language:
7

en Drawing No.:
Zeichnungs Nr.:
8

HFO Separator Double Unit (HFO 1)

8106-2011-061
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
62 Bl./Sh.
53
0 1 2 3 4 5 6 7 8 9

Cable layout

Cable name /page.path Source (from) Target (to) Cable type Wires total Wires used Cross-section Length Cable gland / clamping range Remark

=0-W001 &EFS/10.2 =0-PE;=0-X1 =Customer+L-X _-J 3x 3 1,5 mm² M20x1,5 / 8-13mm

=0-X1_W1 &EFS/10.1 =0-PE;=0-XQ1 =Customer+L-X _-J 4x 4 25 mm² M40x1,5 / 19-28mm

=0-X1_W17 &EFS/12.1 =0-X1 =0-S01 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=01-WG001 &EFS/16.5 =01-X2 =01-13_7_020 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=01-WG021 &EFS/19.6 =0-PE;=01-X2 =01+HFO2-X2 .-J 7x 7 1 mm² M25x1,5 / 11-17mm

=01-X0_W3 &EFS/19.2 =0-PE;=01-X2 =01-10_7_014 .-J 7x 6 1 mm² M25x1,5 / 11-17mm

=01-X1_W2 &EFS/13.1 =0-PE;=01-X1 =01-10_1_001 _-J 4x 4 16 mm² M32x1,5 / 15-21mm

=01-X1_W4 &EFS/18.1 =01-X2 =01-10_7_006 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=01-X1_W5 &EFS/17.4 =0-PE;=01-X2 =01+JB-1X10 .-J 7x 7 1 mm² M25x1,5 / 11-17mm

=01-X1_W9 &EFS/16.1 =0-PE;=01-X2 =01+JB-1X10 .-J 7x 7 1 mm² M25x1,5 / 11-17mm

=01-X1_W13 &EFS/13.3 =01-X2 =01-10_1_001 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=11-WG004 &EFS/23.1 =11-X2 =11-10_9_009 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=11-X1_W3 &EFS/20.1 =0-PE;=11-X1 =11-10_3_001 _-J 4x 4 2,5 mm² M25x1,5 / 11-17mm

=11-X1_W12 &EFS/22.5 =11-X2 =11-10_9_008 .CY-O 4x 4 1 mm² M25x1,5 / 11-17mm

=11-X1_W14 &EFS/22.3 =11-X2 =11-10_7_012 .CY-O 2x 2 1 mm² M20x1,5 / 8-13mm

=16-WG010 &EFS/25.1 =0-PE;=16-X2 =16+HFO2-X2 .-J 3x 3 1 mm² M25x1,5 / 11-17mm

=16-X0_W4 &EFS/24.9 =16-X2 =16-98_7_002 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=16-X0_W5 &EFS/24.7 =16-X2 =16-90_9_001 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=16-X0_W6 &EFS/24.5 =16-X2 =16-90_9_002 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Cable layout
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 54
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Cable layout

Cable name /page.path Source (from) Target (to) Cable type Wires total Wires used Cross-section Length Cable gland / clamping range Remark

=16-X0_W7 &EFS/24.3 =16-X2 =16-90_9_003 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=100-X1_W18 &EFS/27.6 +DCS-X =100-X2 .CY-O 4x 4 1,5 mm² M25x1,5 / 11-17mm

=100-X1_W19 &EFS/26.1 +DCS-X =100-X2;=0-PE .-J 18x 18 1,5 mm² M40x1,5 / 19-28mm

=100-X1_W20 &EFS/27.1 +DCS-X =100-X2;=0-PE .-J 7x 7 1,5 mm² M32x1,5 / 15-21mm

=01+JB-WG101 &EFS/15.1 =01+JB-1X10 =01-10_9_018 .-O 2x 2 0,34 mm² M12x1,5 / 3-6mm

=01+JB-WG104 &EFS/17.1 =01+JB-1X10 =01-10_9_020 _CY-O 4x 4 0,75 mm² M16x1,5 / 5-10mm

=01+JB-WG105 &EFS/18.3 =01+JB-1X10 =01-19_7_003/B .-J 3x 3 1,5 mm² M16x1,5 / 5-10mm

=01+JB-WG106 &EFS/18.4 =01+JB-1X10 =01-19_7_003/A .-J 3x 3 1,5 mm² M16x1,5 / 5-10mm

=01+JB-WG121 &EFS/16.1 =01+JB-1X10 =01+SB-1X20 .-J 5x 5 1,5 mm² M16x1,5 / 5-10mm

=01+JB-WG122 &EFS/18.5 =01+JB-1X10 =01+SB-1X20 .-J 4x 4 1,5 mm² M16x1,5 / 5-10mm

Integrated in the sensor


=01+SB-WG201 &EFS/16.1 =01+SB-1X20 =01-11_9_002 .-O 2x 2 0,34 mm²
block
Integrated in the sensor
=01+SB-WG202 &EFS/16.2 =01+SB-1X20 =01-10_9_014 .-O 2x 2 0,34 mm²
block
Integrated in the sensor
=01+SB-WG203 &EFS/16.3 =01+SB-1X20 =01-10_9_013 .-O 3x 3 0,75 mm²
block
Integrated in the sensor
=01+SB-WG204 &EFS/18.5 =01+SB-1X20 =01-10_7_010 .-J 3x 3 0,75 mm²
block
Integrated in the sensor
=01+SB-WG205 &EFS/18.6 =01+SB-1X20 =01-10_7_011 .-J 3x 3 0,75 mm²
block

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Cable layout
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 55
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Hinweise zur Installation von Kabeln und Leitungen


Directions for installation from cables and conductors

* Schutzmaßnahmen nach Bestimmungen des VDE bzw. zuständigen EVU ausführen!


All protective measures are to be taken in accordance with electric codes, rules and regulations!
* Generell sind die Vorgaben des lokalen Energieversorgers zwingend einzuhalten
In general the the rules and regulations of the lokal power authorities has to be followed.
* Kabel und Leitungen sind so auszuwählen und zu verlegen, dass eine Gefährdung von Personen und der Umgebung ausgeschlossen ist.
Die angegebenen Kabelquerschnitte sind bezogen auf eine Kabellänge von 50m, Kupfer als Leitematerial, Verlegeart "C" und
eine maximale Umgebungstemperatur von 30°C. Siehe hierzu DIN VDE 0298-4 (Verwendung von Kabeln und isolierten Leitungen für Starkstromanlagen - Teil 4:
Empfohlene Werte für die Strombelastbarkeit von Kabeln und Leitungen für feste Verlegung in und an Gebäuden und von flexiblen Leitungen).
Neben der Strombelastung sind bei der Errichtung von Kabel- und Leitungsanlagen weitere Faktoren zu berücksichtigen.
Siehe hierzu IEC 60364-5-52 (Errichten von Niederspannungsanlagen - Teil 5: Auswahl und Errichtung elektrischer Betriebsmittel - Kapitel 52: Kabel- und Leitungsanlagen)
Cables and lines must be selected and laid in a way to eliminate any risk to persons and the environment.
The cable cross-sections specified in these drawings are based on a max. length of 50m, copper as conducting material,laying version "C" and a maximum ambient temperature of 30°C.
Refer also to DIN VDE 0298-4 (Usage of cables and cords in power installations - Part 4:
Recommended current-carrying capacity for sheathed and nonsheathed cables for fixed wirings in and around buildings and for flexible cables and cords).
Besides the current load are in the erection of wiring systems additional parameters to take into account.
Refer also to IEC 60364-5-52 (Erection of low voltage installations - Part 5: Selection and erection of electrical equipment - Chapter 52: Wiring systems)
* Messleitungen sind grundsätzlich abgeschirmt zu verlegen!
Measuring lines must always be laid shielded!
* WD-Kabel getrennt vom WF-/WG-Kabeln verlegen!
WD-cables to be installed separate from WF-/WG-cable!
* Alle Kabel müssen den Flammentest Anforderungen für gebündelte Kabel nach IEC 60332-3 / IEEE 45-18.13 gerecht werden.
All cables must meet the flame test requirements for bunched cables acc. to IEC 60332-3 / IEEE 45-18.13.
* Das gesamte Kabelmaterial muss halogenfrei nach IEC 60754-1, giftfrei nach IEC 60754 und korrosionsfrei nach IEC 60754-2 sein
All cable materials must be free of halogens acc. to IEC 60754-1, no toxicity acc. to 60754 and no corrosivity acc. to IEC 60754-2.
* Alle Kabel müssen eine Abnahme der relevante Abnahmegesellschaft haben. Isolierungsfestigkeit: 0.6/1KV
All cables must have an approval of the relevant classification society. Insulating strength: 0.6/1KV * GEA WSPN Standard: Nexans MPRX 0.6/1kV.

WD-Kabel Energiekabel < 1kV WE-Kabel Erdungs-/Potentialausgleichsleiterleiter


WD-cable = Energy cable < 1kV WE-cable = Earth-/ Equipotential bonding conductor
WF-Kabel Datenbus WG-Kabel Steuer-/ Messkabel WH-Kabel Lichtwellenleiter
WF-cable = Data bus WG-cable = Control-/measuring cable WH-cable = Optical fibre

* Legende Kabeltypen (Kabelliste)


Legend cable typ (list of cables)

Kabel / Leitung mit Schutzleiter


-J = Cable / conductor with protective conductor FC.CY = Motorkabel FU mit konzentrischem Außenleiter (PE)
Motor cable FC with concentric outer (PE)
Kabel / Leitung ohne Schutzleiter
-O = Cable / conductor without protective conductor PL = Potentialausgleichsleiter
Equipotential bonding conductor
Kabel / Leitung mit Schutzleiter geschirmt
CY-J = Cable / conductor with protective conductor screened Ex-CY = Steuerleitung blau für eigensichere Stromkreise
Control line blue for intrinsically safecircuits
Kabel / Leitung ohne Schutzleiter geschirmt
CY-O = Cable / conductor without protective conductor screened CY-TP = Datenleitung paarverseilt
Data line twisted pair
Motorkabel FU geschirmt mit Schutzleiter
FC.CY-J = Motor cable FC screened with protective conductor

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Instructions for installation
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 56
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

FU
FC

=..-U.
Generelle Information zum Potentialausgleich.
Die Informationen auf diesem Blatt sind nicht
kundenspezifisch angepasst.
IP54

General Information for the equipotential bonding system.


≥10 mm²
GN YE Please note, that the information shown on this page are
not customised.

PE-Schiene
protective earth - rail

IDM

≥25 mm²
GN YE

≥10 mm²
GN YE

PA
PA7

PA6

PA5

PA4

PA3

PA2

PA1

≥10 mm²
GN YE
equipotential bonding building
Potentialausgleich Gebäude

≥25 mm²
GN YE

Fundamenterder
foundation earth

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Potential equalization Separator
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 57
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EMB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Parts list

Function sign /page.path WS part-no. Manufacturer order no.. Name Manufacturer

=0-F01 &EFS/10.6 0005-4560-160 23750 Sicherungsautomat C 6A, 2 pol, C60N Groupe Schneider
Circuit breaker
=0-024M &EFS/10.6 0005-4708-890 1031400000 Durchgangs-Reihenklemme, 1,5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 1,5 mm², screw connection, Wemid, dark-beige, TS 35
=0-Q1 &EFS/10.1 0005-1837-060 LV429631 Compact Leistungsschalter, NSX100F+TM80D 3P3D 56-80A, 36KA/415VAC Groupe Schneider
Compact circuit breaker
=0-Q1 &EFS/10.1 Konsole 90X160X100 Konsole 90X160X100 Konsole verzinkt Zimmermeyer
Bracket zinced
=0-Q1 &EFS/10.1 0005-1438-200 29450 Hilfsschalter OF/SD/SDE/SDV für NS/NSX100..630 Groupe Schneider
auxiliary contact
=0-Q1 &EFS/10.1 0005-1837-160 LV429515 Klemmenabdeckung kurz, 3-polig für NSX100/160/250 Groupe Schneider
Cover of terminals, short
=0-Q1 &EFS/10.1 0005-1837-180 LV429338 Drehantrieb mit Türkupplung für NSX 100...250, Standard, schwarzer Griff Groupe Schneider
Front-rotating drive, black
=0-T01 &EFS/10.5 0005-1407-020 6EP1333-2AA01-0AA0 Einphasennetzgeraet Prim.: 120/230V, 50/60Hz, Sec.: 24VDC, 5A Siemens
Single phase power supply
=0-X1 &EFS/10.2; 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=0-F1 &EFS/11.1 0005-1872-670 3RV2411-0KA10 Leistungsschalter, 0,9...1,25A, BGR S00, für den Transformatorschutz Siemens
Circuit-breaker, 0.9...1.25A, size S00, transformer protection
=0-F2 &EFS/11.1 0005-1428-000 23732 Sicherungsautomat C 6A, 1 pol, C60N Groupe Schneider
Circuit breaker
=0-M1 &EFS/11.1 0005-1409-390 116 43 10 1 055 Filterlüfter, 207-253V, 50/60Hz, 45/39W, 231/265m³/h Pfannenberg
Filter fan
=0-M1 &EFS/11.1 0005-1409-240 117 40 00 1 055 Austrittsfilter Pfannenberg
Discharge filter
=0-24M &EFS/11.6 0005-4708-890 1031400000 Durchgangs-Reihenklemme, 1,5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 1,5 mm², screw connection, Wemid, dark-beige, TS 35
=0-T1 &EFS/11.1 0005-0551-490 700199 Steuerspannungstransformator, Prim.: 200-560VAC, Sek.: 115/230V, 400VA Ismet
Control voltage transformer, prim.: 200-560 VAC, sec.: 115/230 V, 400 VA
=0-T2 &EFS/11.5 0005-1407-020 6EP1333-2AA01-0AA0 Einphasennetzgeraet Prim.: 120/230V, 50/60Hz, Sec.: 24VDC, 5A Siemens
Single phase power supply
=0-K1 &EFS/12.6 0005-4033-110 2966207 Relais Einzelkontakt,PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Phoenix Contakt
Relay for single contact, PLC interface, miniature relay with power contact, 1 change-over
=0-S01 &EFS/12.1 0005-0081-030 3SB3801-0DF3 Pilzdrucktaster Gehäuse, verrastend, mit Schutzkragen, 1NC, 2x M20 Siemens
Mushroom push button box
=0-S01 &EFS/12.1 0005-4487-930 70-20-060-000-13-041 Verschraubung Polyamid, M20x1,5, RAL 7032, halogenfrei, d=8-13mm Jacob
Screw connection polyamide, M20x1,5, RAL 7032, halogen free, 8-13mm
Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Parts list
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 58
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EPB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Parts list

Function sign /page.path WS part-no. Manufacturer order no.. Name Manufacturer

=0-S01 &EFS/12.1 0013-0132-900 50225 PA7035 Gegenmutter Polyamid, M25x1,5, RAL 7035 Jacob
Counter nut polyamide, M25x1,5, RAL 7035
=01-B1 &EFS/13.1 0005-0924-090 TAID10C100 Stromwandler, 100/1A IME
Current transformer
=01-F1 &EFS/13.4 0005-1100-070 3RN1010-1CM00 THERMISTOR-MOTORSCHUTZ, STANDARD-AUSWERTEGERÄT, AUTO, 1S+1OE, AC 230V Siemens
THERMISTOR MOTOR PROTECTION EVALUATION UNIT AUTO, 1NO+1NC, AC 230V
=01-Q1 &EFS/13.8 0005-4382-270 3RT1044-1AL20 Leistungsschütz, 30KW/400V, 230VAC 50/60HZ, 3POLIG, BGR. S3, SCHRAUBANSCHLUSS Siemens
CONTACTOR, AC-3 30 KW/400 V, AC 230V 50/60HZ 3-POLE, SIZE S3, SCREW
=01-Q1 &EFS/13.8 0005-4399-050 3RH1921-1HA31 HILFSSCHALTERBLOCK, 31, 3S+1OE, DIN EN 50012, 4POLIG, FÜR MOTORSCHÜTZE, BGR. Siemens
AUXILIARY SWITCH BLOCK, 31, 3NO+1NC
=01-Q1 &EFS/13.8 0005-0915-170 3RT1936-1CD00 RC-GLIED, AC 127...240V, UEBERSPANNUNGSBEGRENZER, ZUM AUFSETZEN, BGR. S2, S3 Siemens
RC-ELEMENT, AC 127...240 V, SURGE SUPPRESSOR
=01-T1 &EFS/13.2 0005-3482-070 1073490000 Stromüberwachung, 0...1 A AC/ 0...5 A AC/ 0...10 A AC , 1 , 0(4)...20 mA , 0...10 V , 1 Weidmueller
Current monitoring, 0 - 1 A AC/0 - 5 A AC/0 - 10 A AC, 1, 0(4) - 20 mA , 0 - 10 V , 1 screw
=01-X1 &EFS/13.1 1028800000 1028800000 Durchgangs-Reihenklemme, 35 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal
=01-X1 &EFS/13.7; 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=01-X2 &EFS/13.3; 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=01-K1 &EFS/14.1 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=01-T2 &EFS/15.1 0005-4509-000 KCD2-E2 Sensor-Endstufenklemme, Eingang für NAMUR-Sensoren, 24V DC Speisespannung Pepperl & Fuchs
Converters- Amplifier to convert NAMUR sensor
=01-K10 &EFS/19.1 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=01-K11 &EFS/19.3 0005-1870-200 3RH2140-1JB40 Koppelhilfsschütz, 4S DC 24V, mit Diode Siemens
Coupling contactor relay, 4NO DC 24V, integrated diode
=01-K12 &EFS/19.4 0005-1870-200 3RH2140-1JB40 Koppelhilfsschütz, 4S DC 24V, mit Diode Siemens
Coupling contactor relay, 4NO DC 24V, integrated diode
=01-X2 &EFS/19.5 0005-1442-890 1011300000 Sicherungs-Reihenklemme, 6 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Fused terminal block, 6 mm², screw connection, Wemid, dark-beige, TS 35
=01-X2 &EFS/19.5 0005-0541-020 5X20MM 0,5A MT Feinsicherung 5x20, 0,5A/MT, 250V Plenge
Miniature fuse
=11-Q1 &EFS/20.0 0005-1730-000 LUB12 Motorabgang Grundgerät - 12A AC-43, 440V Groupe Schneider
Motor outlet of basic unit - 12 A AC-43, 440 V
=11-Q1 &EFS/20.0 0005-1730-130 LUCA12FU Steuereinheit Standard LUCA - class 10, 3-12A 110-220V DC/AC Groupe Schneider
Standard control unit LUCA - class 10, 3-12A 110-220V DC/AC
Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Parts list
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 59
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EPB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Parts list

Function sign /page.path WS part-no. Manufacturer order no.. Name Manufacturer

=11-Q1 &EFS/20.0 0005-1730-310 LUA1C20 Hilfsschaltermodul MSS LUA, 2S Groupe Schneider


Aux. switch module, MSS LUA, 2 NO.
=11-X1 &EFS/20.1 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=11-K2 &EFS/21.1 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=11-T1 &EFS/22.5 0005-3482-060 8483680000 Signalwandler/-trenner, 4...20 mA (Stromschleife), Zugfederanschluss Weidmueller
Signal converter/disconnector, 4...20 mA (current loop), Tension clamp connection
=11-X2 &EFS/22.4.. 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=11-X2 &EFS/22.3 0005-3499-890 1020080000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, blau, TS 35 Weidmueller
Feed-through terminal
=16-K1 &EFS/24.1 0005-1406-020 3RH1140-1JB40 KOPPELSCHÜTZ, 4S, DC 24V, 0,7...1,25*US, M.DIODE, BGR. S00 Siemens
COUPLING RELAY, 4NO, DC 24 V, 0.7...1.25*US, W.DIODE, SIZE S00
=16-K2 &EFS/24.3 0005-4033-080 2967060 Relais Mehrfachkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 2 Wechsler, Phoenix Contakt
Relay, PLC interface, relay with power contact, 2 change-over contacts, Un=24 VDC
=16-K3 &EFS/24.5 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=16-K4 &EFS/24.6 0005-1870-200 3RH2140-1JB40 Koppelhilfsschütz, 4S DC 24V, mit Diode Siemens
Coupling contactor relay, 4NO DC 24V, integrated diode
=16-P1 &EFS/24.2 0005-1553-000 3SB3001-6AA20/LED/24 Leuchtmelder komplett, LED rot 24V AC/DC, Siemens
Pilot light complete
=16-S1 &EFS/24.1 0005-1439-010 3SB3000-2DA11-BB Schwenksteller komplett, rastend, schwarz, I-0-II, 2x 1NO Siemens
Selector switch complete
=16-S2 &EFS/24.2 0005-1414-100 3SB3000-0AA11-B Drucktaster komplett, schwarz, 1NO Siemens
Push button complete
=16-X2 &EFS/24.4.. 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=16-X2 &EFS/24.9 0005-1442-890 1011300000 Sicherungs-Reihenklemme, 6 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Fused terminal block, 6 mm², screw connection, Wemid, dark-beige, TS 35
=16-X2 &EFS/24.9 0005-0541-020 5X20MM 0,5A MT Feinsicherung 5x20, 0,5A/MT, 250V Plenge
Miniature fuse
=100-K1 &EFS/26.1 0005-4033-080 2967060 Relais Mehrfachkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 2 Wechsler, Phoenix Contakt
Relay, PLC interface, relay with power contact, 2 change-over contacts, Un=24 VDC
=100-K2 &EFS/26.3 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=100-K3 &EFS/26.4 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Parts list
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 60
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EPB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Parts list

Function sign /page.path WS part-no. Manufacturer order no.. Name Manufacturer

=100-K4 &EFS/26.5 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=100-K5 &EFS/26.6 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=100-K6 &EFS/26.7 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=100-X2 &EFS/26.1.. 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=0-SC &EFS/27.7; 1600480000 1600480000 Klemmbügel für Schirmanschluss, zur Montage auf Sammelschiene 10x3mm Weidmueller
Retaining clip for shield connection
=00-P1 &EFS/30.1 0005-4050-710 6AV6642-5DA10-1AC0 Prozessanzeige OP177B, Farb-Display, 24VDC Siemens
Process display OP177B
=00-P1 &EFS/30.1 6AV6671-1CB00-0AX2 6AV6671-1CB00-0AX2 Speicherkarte, 128 MByte, MMC Siemens
Memory card
=00-K1 &EFS/31.1 0005-4050-720 6ES7313-5BF03-0AB0 Zentralbaugruppe, CPU 313C Siemens
CPU modul
=00-K1 &EFS/31.1 0005-4050-760 6ES7390-1AE80-0AA0 Profilschiene, 480mm Siemens
Profile bar, 480mm
=00-K1 &EFS/31.1 0005-4050-722 6ES7392-1AM00-0AA0 Frontstecker, 40POLIG Siemens
Front connector, 40 PIN
=00-K1 &EFS/31.1 6ES7953-8LG20-0AA0 6ES7953-8LG20-0AA0 Speicherkarte, 128 kByte, MMC Siemens
Memory card, 128 kByte, MMC
=00-K1 &EFS/31.1 6ES7901-0BF00-0AA0 6ES7901-0BF00-0AA0 MPI-Kabel zur Verbindung von SIMATIC S7 und PG über MPI, 5M Siemens
MPI cable
=00-K2 &EFS/31.4 6ES7331-1KF02-0AB0 6ES7331-1KF02-0AB0 Analogbaugruppe Eingang, SM 331, 8AE, 13BIT Siemens
Analog module input, SM 331, 8AI, 13BIT
=00-K2 &EFS/31.4 0005-4050-722 6ES7392-1AM00-0AA0 Frontstecker, 40POLIG Siemens
Front connector, 40 PIN
=00-K3 &EFS/31.5 0005-4281-010 6ES7332-5HB01-0AB0 Analogbaugruppe Ausgang, SM 332, 2AA, U/I, 11/12BIT Siemens
Analog Module Output, SM 332, 2AO, U/I, 11/12BIT
=00-K3 &EFS/31.5 0005-4050-731 6ES7392-1AJ00-0AA0 Frontstecker, 20POLIG Siemens
Front connector, 20 PIN
=00-K4 &EFS/31.6 0005-4050-730 6ES7323-1BH01-0AA0 Digitalbaugruppe Ein-/Ausgang, SM 323, 8DE/DA, DC 24V, 0.5A Siemens
Digital Module Input/Output, SM 323, 8DI/DO, DC 24V, 0.5A
=00-K4 &EFS/31.6 0005-4050-731 6ES7392-1AJ00-0AA0 Frontstecker, 20POLIG Siemens
Front connector, 20 PIN
-Cabinet &ELU/37.1 1260500 1260500 Kompakt-Schaltschrank AE, lackiert RAL 7035, eintürig mit Montageplatte Rittal
Compact enclosure AE, painted RAL 7035, single door with mounting plate
Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Parts list
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 61
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EPB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Parts list

Function sign /page.path WS part-no. Manufacturer order no.. Name Manufacturer

-Cabinet &ELU/37.1 0005-1412-000 2519000 Türarretierung für das AE Programm Rittal


Door stay for the AE range
-Cabinet &ELU/37.1 RESOPALSCHILD100/13 RESOPALSCHILD100/13 Resopalschild Kaiser
0 0 Resopal plate
-Cabinet &ELU/37.1 8556-9999-000 KLEINMATERIAL Kleinmaterial Schaltschrank Plenge
Incidentals control cabinet
-Cabinet &ELU/37.1 ADERKENNZEICHNUNG ADERKENNZEICHNUNG Aderkennzeichnung Plenge
Wire marking
-Cable_Glands &ELU/37.9 0013-0131-900 50220 PA7035 Gegenmutter Polyamid, M20x1,5, RAL 7035 Jacob
Counter nut polyamide, M20x1,5, RAL 7035
-Cable_Glands &ELU/37.9 0005-4487-930 70-20-060-000-13-041 Verschraubung Polyamid, M20x1,5, RAL 7032, halogenfrei, d=8-13mm Jacob
Screw connection polyamide, M20x1,5, RAL 7032, halogen free, 8-13mm
-Cable_Glands &ELU/37.9 0013-0132-900 50225 PA7035 Gegenmutter Polyamid, M25x1,5, RAL 7035 Jacob
Counter nut polyamide, M25x1,5, RAL 7035
-Cable_Glands &ELU/37.9 0005-4488-930 70-25-060-000-17-041 Verschraubung Polyamid, M25x1,5, RAL 7032, halogenfrei, d=11-17mm Jacob
Screw connection polyamide, M25x1,5, RAL 7032, halogen free, 11-17mm
-Cable_Glands &ELU/37.9 50232-PA7035 50232 PA7035 Gegenmutter Polyamid, M32x1,5, RAL 7035 Jacob
Counter nut polyamide, M32x1,5, RAL 7035
-Cable_Glands &ELU/37.9 0005-4489-930 70-32-060-000-21-041 Verschraubung Polyamid, M32x1,5, RAL 7032, halogenfrei, d=15-21mm Jacob
Screw connection polyamide, M32x1,5, RAL 7032, halogen free, 15-21mm
-Cable_Glands &ELU/37.9 50240-PA7035 50240 PA7035 Gegenmutter Polyamid, M40x1,5, RAL 7035 Jacob
Counter nut polyamide, M40x1,5, RAL 7035
-Cable_Glands &ELU/37.9 0005-4490-930 70-40-060-000-28-041 Verschraubung Polyamid, M40x1,5, RAL 7032, halogenfrei, d=19-28mm Jacob
Screw connection polyamide, M40x1,5, RAL 7032, halogen free, 19-28mm
-Cable_Glands &ELU/37.9 0005-4443-900 81-20-866-0000-04 Blindstopfen Polyamid, M20x1,5, RAL 7035 Jacob
Blanking plug polyamide, M20x1,5, RAL 7035
-Cable_Glands &ELU/37.9 0005-4444-900 81-25-866-0000-04 Blindstopfen Polyamid, M25x1,5, RAL 7035 Jacob
Blanking plug polyamide, M25x1,5, RAL 7035
=Additions &ELU/37.9 0005-1554-000 1646461044 Kabelbezeichnung, polyamid Weidmueller
Cable designation
=Additions &ELU/37.9 8555-9001-200 8555-9001-200 Betriebsanleitung E40, englisch WS Mineraloil Systems
Instruction manual

Date 19.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Parts list
HFO Separator Double Unit (HFO 1) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 62
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-061 & EPB 62 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

GEA Westfalia Separator


Werner-Habig-Str. 1 - 59302 Oelde ( Germany ) - Phone +49 2522 77-0

Customer : PDV Power Technology

Designation of plant : HFO Separator Double Unit (HFO 2)

Drawing no. : 8106-2011-062

Internal order no. : 1 451 119 792

Manufacturer (company) : GEA Westfalia Separator

Name of project : Esmeraldas II

Type : E40 / OSE 80-0136-067

Language : en

Technical data : 480V AC 60 Hz +/-5 % -

Prepared : 18.07.2012 Processed : 07.09.2012 Applied standards IEC 81346


IEC 61355
IEC 60617
GEA project contact : M. Kalb Telephone : +49 2522 77-2802

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Title- / cover sheet
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 1
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EAA 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Table of contents

Document type Page Page description Plant Mounting place Date Editor

&EAA 1 Title- / cover sheet 20.07.2012 GUE/PLE

&EAB 2 Table of contents 20.07.2012 GUE/PLE

&EAB 3 Table of contents 20.07.2012 GUE/PLE

&EAB 4 Table of contents 20.07.2012 GUE/PLE

&EBH 6 Revision overview 20.07.2012 GUE/PLE

&EDB 7 Structure indicator 20.07.2012 MAR/PLE

&EDB 8 Information-sheet 20.07.2012 GUE/PLE

&EDB 9 Information-sheet 20.07.2012 GUE/PLE

&EFS 10 Incoming =0 20.07.2012 GUE/PLE

&EFS 11 Control voltage =0 20.07.2012 GUE/PLE

&EFS 12 Emergency stop =0 20.07.2012 GUE/PLE

&EFS 13 Separator =01 20.07.2012 GUE/PLE

&EFS 14 Separator =01 20.07.2012 GUE/PLE

&EFS 15 Separator speed measuring =01 20.07.2012 GUE/PLE

&EFS 16 Separator signals =01 20.07.2012 GUE/PLE

&EFS 17 Separator vibro =01 20.07.2012 GUE/PLE

&EFS 18 Separator valves =01 20.07.2012 GUE/PLE

&EFS 19 Separator clean-oil discharge =01 20.07.2012 GUE/PLE

&EFS 20 Feed pump =11 20.07.2012 GUE/PLE

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Table of contents
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 2
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EAB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Table of contents

Document type Page Page description Plant Mounting place Date Editor

&EFS 21 Feed pump =11 20.07.2012 GUE/PLE

&EFS 22 Product temperature control =11 20.07.2012 GUE/PLE

&EFS 23 FI flow measuring =11 20.07.2012 GUE/PLE

&EFS 24 Sludge pump =16 20.07.2012 GUE/PLE

&EFS 25 Signal exchange =100 20.07.2012 GUE/PLE

&EFS 26 Signal exchange =100 20.07.2012 GUE/PLE

&EFS 27 PLC overview =00 20.07.2012 GUE/PLE

&EFS 28 PLC overview =00 20.07.2012 GUE/PLE

&EFS 29 Process display OP 177B =00 20.07.2012 GUE/PLE

&EFS 30 PLC power supply =00 20.07.2012 GUE/PLE

&EFS 31 PLC overview =00 20.07.2012 GUE/PLE

&EFS 32 PLC overview =00 20.07.2012 GUE/PLE

&EFS 33 PLC overview =00 20.07.2012 GUE/PLE

&EFS 34 PLC overview =00 20.07.2012 GUE/PLE

&EFS 35 PLC overview =00 20.07.2012 GUE/PLE

&ELU 36 Arrangement drawing control cabinet 20.07.2012 GUE/PLE

&ELU 37 E40 20.07.2012 GUE/PLE

&EMA 38 Terminal connecting plan =0+-24M 20.07.2012 GUE/PLE

&EMA 39 Terminal connecting plan =0+-PE 20.07.2012 GUE/PLE

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Table of contents
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 3
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EAB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Table of contents

Document type Page Page description Plant Mounting place Date Editor

&EMA 40 Terminal connecting plan =0+-SC 20.07.2012 GUE/PLE

&EMA 41 Terminal connecting plan =0+-X1 20.07.2012 GUE/PLE

&EMA 42 Terminal connecting plan =0+-XQ1 20.07.2012 GUE/PLE

&EMA 43 Terminal connecting plan =01+-X1 20.07.2012 GUE/PLE

&EMA 44 Terminal connecting plan =01+-X2 20.07.2012 GUE/PLE

&EMA 45 Terminal connecting plan =01+JB-1X10 20.07.2012 GUE/PLE

&EMA 46 Terminal connecting plan =01+SB-1X20 20.07.2012 GUE/PLE

&EMA 47 Terminal connecting plan =11+-X1 20.07.2012 GUE/PLE

&EMA 48 Terminal connecting plan =11+-X2 20.07.2012 GUE/PLE

&EMA 49 Terminal connecting plan =16+-X2 20.07.2012 GUE/PLE

&EMA 50 Terminal connecting plan =100+-X2 20.07.2012 GUE/PLE

&EMB 51 Cable layout 20.07.2012 GUE/PLE

&EMB 52 Cable layout 20.07.2012 GUE/PLE

&EMB 53 Instructions for installation 20.07.2012 GUE/PLE

&EMB 54 Potential equalization Separator 20.07.2012 GUE/PLE

&EPB 55 Parts list 20.07.2012 GUE/PLE

&EPB 56 Parts list 20.07.2012 GUE/PLE

&EPB 57 Parts list 20.07.2012 GUE/PLE

&EPB 58 Parts list 20.07.2012 GUE/PLE

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Table of contents
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 4
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EAB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Revision overview

Revision name Revision comment Revision on the basis of change Page name Author Date

Rev.01 Customer comments included MAR/PLE 26.07.2012

Rev.02 Customer comments included MAR/PLE 27.07.2012

Rev.03 Customer comments included (Cable gland size) GUE/PLE 03.08.2012

Rev.04 Customer comments included (Cable cross-section) GUE/PLE 07.08.2012

Rev.05 / As built Factory revision GUE/PLE 07.09.2012

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Revision overview
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 6
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EBH 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Structure indicator

Complete name Labelling Structure descprition Complete name Labelling Structure descprition

&EAA Document type Cover sheet

&EAB Document type Table of contents

&EBH Document type Revision overview

&EDB Document type Structure indentification overview / instructions

&EFS Document type Circuit diagram

&ELU Document type Arrangement drawing

&EMA Document type Terminal connecting plan

&EMB Document type Cable layout

&EPB Document type Parts list

=0 Plant Incoming

=01 Plant Separator

=11 Plant Feed pump

=16 Plant Sludge pump

=100 Plant Signal exchange

=00 Plant PLC

=Additions Plant Addition

=Customer Plant Customer

+JB Mounting place Junction box

+L Mounting place Local

+SB Mounting place Sensor bloc

+HFO1 Mounting place HFO1 control cabinet

+DCS Mounting place

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Structure indicator
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 7
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EDB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Instruction / specification

Control cabinet : Version:

Name control cabinet HFO 2 Core indentification YES

Painting cabinet RAL 7035 Potential designation NO

Protective rating IP54 Halogen free wiring / channels NO

Ambient temperature ~45 °C Cable marking plates YES

Classification ...

Marking plates PLASTIC WHITE, LETTERS BLACK

Interface:

Bus connection to customer PLC NO

Incoming:

Mains- / side voltage 480V AC

Mains frequency 60 Hz

Rotary field

Voltage tolerance +/-5 %

Cable inlet BOTTOM

Incoming redundant NO

Control voltages:

Control voltage 1 220V AC

Control voltage 2 24V DC

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Information-sheet
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 8
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EDB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Wiring

Electrical circuits Conductor Colour Cross-section Electrical circuits Conductor Colour Cross-section

Main circuits 480V AC L1 Black ≥ 1,5mm² Control voltage 220V AC L Red ≥ 0,75mm²

L2 Black " N Red / white "


L3 Black "
N Light blue ≥ 1,5mm²

PE Green / yellow ≥ 2,5mm²

Control voltage 24V DC + Dark blue ≥ 0,75mm²

- Blue / white "

Analog screened L+ White ≥ 0,75mm²

M Brown "

Measuring circuit White ≥ 0,75mm²

Current transformer lines Black ≥ 2,5mm²

Interlocking conductors (AC/DC) Orange ≥ 0,75mm²

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Information-sheet
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 9
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EDB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

480V AC
L1 / 13.0
L2 / 13.0
L3 / 13.0
480V AC
L1.2 / 20.0
L2.2 / 11.0
L3.2 / 11.0

12

14
1

-Q1
/25.1 11

56-80A
In: 74A
I> I> I>
2

Data incoming:
-PE -PE -SC -PE -PE -PE
Min. Cross-section:
25 mm²

-X2_W1
Pre-fuse:
_-J NH 80A
4x25 mm²
PE

PE

PE

Ambient temperature:
~45 °C
-1M -1T -1G
PE
L1

L2

L3

Max. Cable length:


50 m
Earthing mounting plate 1

=Customer
U: 480V AC
+L-X
Earthing cabinet 1

-
Earthing door 1

f: 60 Hz
P: ~33 kW
Incoming Earthing screen
Icn: 36 kA

Full load current:


~77 A

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 0
Editor GUE/PLE
Customer:
Separator Incoming
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 10
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

480V AC 480V AC
10.9 / L2.2 L2.2 / 20.0
10.9 / L3.2 L3.2 / 20.0
220V AC
L.A / 13.4
N.A / 12.0
220V AC
L.X / 12.0
1

5
-F1 N.X /
0,9...1,25A
EW:0,97A
I> I> I>
2

6
480V AC

480V AC

N/L2
L1
-T1 A F C K -T2
INPUT
400VA 120/230VAC GEA
24VDC/5A power

GND

OFF

ON
ua va PE ub vb
220V AC

220V AC

A
B
OUTPUT

-PE

L+

L+'

PE

M'
M.A / 13.2
-PE
M.K / 27.0
M.R / 14.0

2
-24M
1

-F2
2

C6A
-PE
M.T / 29.0
M.X / 18.0
24V DC
L+.A / 12.7
24V DC
L+.K / 30.0
24V DC
L+.X / 16.0
24V DC
L+.T / 29.0
1

-X1

-PE

-PE
N
L

-M1
M
45/39W 1~
Cabinet fan
PE

Control voltage AC Control voltage DC

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 0
Editor GUE/PLE
Customer:
Separator Control voltage
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 11
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

220V AC 220V AC
11.9 / L.X L.X /
220V AC
1L.X / 13.4
220V AC
1L.A / 20.4

7
-X1

24V DC 24V DC
11.9 / L+.A L+.A / 13.2

11
-K1

12

14
/12.6

29
X11
E2.7
/31.5

=00-K1
Separator
emergency stop

A1
-K1

A2
11.9 / N.A N.A / 13.4
Remove link in case of
an external
8

emergency stop!
(optional) -X1

-X2_W17
.-O
2x1 mm²
21

14
11 /12.8
12
-S01
22

Emergency stop external Emergency stop

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 0
Editor GUE/PLE
Customer:
Separator Emergency stop
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 12
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC 220V AC 220V AC


10.9 / L1 12.9 / L+.A L+.A / 14.0 11.9 / L.A L.A /
220V AC
10.9 / L2 11.9 / M.A M.A / 15.0 12.9 / 1L.X
10.9 / L3

Current measuring separator

=00-K1
4-20mA = 0-50A
/31.4
PEW752I
X11

13
-F1

14
/13.4

11
1

-Q1 -K1
-T1
2

12

14
/13.8 /14.1
*0_9_011
7+
2
S1

Input
8

0-1A
-B1
3

Output
9-
S2

100/1A 0/4-20mA

A1

A1
T1
-F1 M -Q1
T2

A2

A2
12.9 / N.A N.A / 20.4
-PE
Link remove at
connection of an
sludge discharge flap!
1

5
(optional)
-X1 -X2 -X1

-X2_W2 -X2_W13
_-J .-O
4x16 mm² 2x1 mm²
Anti-clockwise rotation
W1
U1

V1

PE

13 14 /13.8 1 2 /13.1
M 21 22 /14.2 3 4 /13.1
20_1_001 3~ 5 6 /13.1
13 14
26,0kW/41,0-43,0A Θ
21 22
T2

T1

33 34 /14.1
43 44 /25.2

Separator PTC-feeler Spare Separator operation


separator

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 13
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
13.3 / L+.A L+.A / 15.0

33

21
-Q1 34 -F1

22
/13.8 /13.4
2

3
X12 X12
E0.0 E0.1
/32.4 /32.4

=00-K1 =00-K1
Separator Separator
operation failure

=00-K1
/32.5
A1.0
X12
32
A1

-K1
A2

11.9 / M.R M.R / 19.0

14
11 /13.8
12

Separator
start/stop

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 14
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
14.9 / L+.A L+.A / 21.0
13.3 / M.A

=00-K1
0-6800 r.p.m.
/32.4
E0.3
X12

-T2 5
4+
6-

24VDC
5+

1+

2-
3

-X2

-X2_W9
.-J
7x1 mm²
/16.1
+JB

-1X10 1 2

+JB-WG101
.-O
2x0,34 mm²
+

20_9_018
SI
-

+ BN = brown
- BU = blue

Speed monitoring device

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator speed measuring
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 15
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K1 =00-K1
4-20mA 4-20mA
/31.4 /31.4
PEW754I PEW756I
X11 X11
=00-K1 =00-K4
6

9
/32.4 /35.5
E0.5 E8.7
X12 X1

9
24V DC 24V DC
11.9 / L+.X L+.X / 19.0

-PE

10

11

12
5

-X2 9

-X2_W9 -WG001
.-J .-O
7x1 mm² 2x1 mm²
/15.1
+JB
L+_1X10 / 17.1
PE
4

-1X10 PE

+JB-WG121
.-J
5x1,5 mm²

+SB
PE_1X20 / 18.6
M_1X20 / 18.5
2

-1X20

+SB-WG201 +SB-WG202 +SB-WG203


.-O .-O .-O
2x0,34 mm² 2x0,34 mm² 3x0,75 mm²
A/Q

13
+
1

23_7_020
21_9_002 I 20_9_014 I 20_9_013
14

PSL/H P SMS P WMS


4-20mA 4-20mA

Clean-oil Sludge room monitoring Water discharge Sludge discharge


discharge pressure flap

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator signals
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 16
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K1
/32.4
E1.7
X12

19
13
-X2

-X2_W5
.-J
7x1 mm²
/18.3
+JB 16.3 / L+_1X10
M_1X10 / 18.3

-1X10 8 11 9 10

+JB-WG104
_CY-O
4x0,75 mm²
SC
1

20_9_020
PCH 1220
+24V DC

0V

-D1

Relay

NAHH separator NAHH separator


vibration monitoring vibration monitoring

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator vibro
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 17
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K1 =00-K1 =00-K1 =00-K1 =00-K1


/32.5 /32.5 /32.5 /32.5 /32.5
A0.0 A0.2 A0.1 A0.4 A0.5
X12 X12 X12 X12 X12
22

24

23

26

27
11.9 / M.X M.X / 22.0

-PE
14

15

16

17

18

19

20

21
-X2

-X2_W5
.-J
7x1 mm²
/17.4
+JB
17.1 / M_1X10

-PE -PE
12

13

15

14

16

18

17

PE
-1X10 PE PE -1X10 PE

+JB-WG122
.-J
4x1,5 mm²

+SB
16.3 / M_1X20
16.3
PE_1X20

11

10
PE

PE
8

9
-1X20 PE PE

-X2_W4 +JB-WG105 +JB-WG106 +SB-WG204 +SB-WG205


.-O .-J .-J .-J .-J
2x1 mm² 3x1,5 mm² 3x1,5 mm² 3x0,75 mm² 3x0,75 mm²
+

PE

PE

PE

PE
+

+
20_7_006 29_7_003/B 29_7_003/A 20_7_010 20_7_011
-

-
-

Feed valve Operating water Displacem- and Circulation valve Water discharge valve
filling water

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator valves
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 18
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
16.9 / L+.X L+.X / 23.0

=00-K1 =00-K1 =00-K1


/32.5 /31.5 /31.5
A1.7 E2.0 E2.1
X12 X11 X11
39

22

23
11
-K10

12

14
/19.1
A1

-K10
A2

14.9 / M.R M.R / 21.0

-PE

22

23

24

25

26

27
-X2

-WG021
.-J
7x1 mm²

+HFO1

PE
27

28

29

30

31

32
8106-2011-061
-X2

24

24
14
11 /19.6 -K11 -K12
12

23

23
Valve Valve Valve clean-oil Spare
clean-oil discharge clean-oil discharge limit switch Valve clean-oil
discharge to HFO1 open from HFO1 discharge limit
switch closed from HFO1

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 01
Editor GUE/PLE
Customer:
Separator Separator clean-oil discharge
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 19
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

480V AC 220V AC
10.9 / L1.2 12.9 / 1L.A
11.9 / L2.2
11.9 / L3.2

5
-Q1

17
3-12A L1 L2 L3

13

21
A1
110-220V DC/AC -Q1

18
/20.2

14

22
A2
/20.7 /21.1

3-12A
110-220V DC/AC
Control module
LUCA12FU
EW:10,5A

11
-K2

14

12
/21.1

17

97
18

98
/20.7 /21.2
T1 T2 T3
2

A1
-Q1

A2
/20.2

13.9 / N.A
-PE
1

-X1

-X2_W3
_-J
4x2,5 mm²

Clockwise rotation Achtung! 13 14 /21.1


W1
U1

V1

PE

21 22
Vor dem Einschalten der Zulaufpumpe 17 18 /20.7
20_3_001
M den Leistungsschalter auf Nennstrom 97 98 /21.2
6,33kW 3 des Motors einstellen (s. Typenschild des Motors)
10,5A
Attention!
Before switch-on feed pump, adjust the circuit breaker
to nominal current of the motor (look at motor label)
Feed pump Feed pump

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 11
Editor GUE/PLE
Customer:
Separator Feed pump
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 20
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
15.9 / L+.A L+.A / 22.0

13

97
-Q1 -Q1
14

98
/20.2 /20.3
12

13
X12 X12
E1.0 E1.1
/32.4 /32.4

=00-K1 =00-K1
Feed pump Feed pump
operation failure

=00-K1
/32.5
A1.1
X12
33
A1

-K2
A2

19.1 / M.R M.R / 25.0

14
11 /20.7
12

Feed pump
start / stop

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 11
Editor GUE/PLE
Customer:
Separator Feed pump
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 21
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
21.9 / L+.A L+.A / 24.0
18.9 / M.X M.X / 26.0

Control valve heating Product Min / max


medium positioner temperature control temperature monitoring
=00-K1 =00-K1 =00-K1
4-20mA 4-20mA = 0-120°C 4-20mA = 0-120°C
/31.4 /31.4 /31.4 /31.4
PAW754I PEW758I PEW760+ PEW760-
X11 X11 X11 X11

12

14

15
19
-SC -SC

1
-T1
Output
0/4-20mA

PT100

-SC

4
-SC
SC

SC
7

4
-X2 -X2

-X2_W14 -X2_W12
.CY-O .CY-O
2x1 mm² 4x1 mm²
/22.3

20_9_008
1

3
Θ Θ
+

PT100 PT100
20_7_012
2

4
SIPART PS2
4-20mA

Control valve heating medium Product Min / max


positioner temperature control temperature monitoring

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 11
Editor GUE/PLE
Customer:
Separator Product temperature control
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 22
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K2
/33.3
PEW256I
X1
2

24V DC 24V DC
19.9 / L+.X L+.X / 26.0
5

-X2

-WG004
.-O
2x1 mm²
1

20_9_009 I
FI P
4-20mA

FI flow measuring

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 11
Editor GUE/PLE
Customer:
Separator FI flow measuring
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 23
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

24V DC 24V DC
22.9 / L+.A L+.A / 27.0

=00-K1
/32.4
E0.7
X12
9

-PE
1

-X2

-WG010
.-J
3x1 mm²

+HFO1
PE
12

13

8106-2011-061
-X2
24

-K4
23

LSHH sludge tank


from HFO1

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 16
Editor GUE/PLE
Customer:
Separator Sludge pump
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 24
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K1 =00-K1 =00-K1 =00-K1 =00-K4 =00-K4


/32.5 /32.5 /32.5 /32.5 /35.5 /35.5
A0.7 A1.3 A1.4 A1.5 A8.0 A8.1
X12 X12 X12 X12 X1 X1
29

35

36

37

12

13
A1

A1

A1

A1

A1

A1
-K1 -K2 -K3 -K4 -K5 -K6
A2

A2

A2

A2

A2

A2
21.9 / M.R

14 14 14 14 14 14
11 11 /25.3 11 /25.4 11 /25.5 11 /25.7 11 /25.8
12 12 12 12 12 12
24
21 /25.0
22
43

12

14

12

14

12

14

12

14

12

14
22

24

12

14

=01-Q1 -K2 -K3 -K4 -K5 -K6


-K1 =0-Q1
44

11

11

11

11

11
/13.8 /25.3 /25.4 /25.6 /25.7 /25.8
21

11

/25.1 /10.1
PE

10

11

12

13

14

15

16

17
1

3
4

9
-X2

-X2_W19
.-J
18x1,5 mm²

=+DCS

PE
-X -X -X -X -X -X -X -X

Common failure Separator Sludge tank TAH TAL Local / remote PAL clean-oil
operation Level high / high alarm HFO temperature HFO temperature status discharge pressure

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 100
Editor GUE/PLE
Customer:
Separator Signal exchange
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 25
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

=00-K4 =00-K4 =00-K4 =00-K3 =00-K3


4-20mA 4-20mA
/35.5 /35.5 /35.5 /34.5 /34.5
E8.0 E8.1 E8.2 PAW272 PAW274
X1 X1 X1 X1 X1
2

7
-SC -SC

=0-SC =0-SC

24V DC 24V DC
23.9 / L+.X L+.X /
22.9 / M.X M.X /
-SC
PE

SC
18

19

20

21

22

23

24

25

26

27
-X2

-X2_W20 -X2_W18
.-J .CY-O
7x1,5 mm² 4x1,5 mm²
/26.8

=+DCS
PE

-X -X -X -X -X

-K -K -K

HFO daily tank level HFO daily tank level Remote start / stop Clean-oil HFO temperature
Low control High control NO for stop, NC for start discharge pressure
Change to daily tank Change to settling tank

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 100
Editor GUE/PLE
Customer:
Separator Signal exchange
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 26
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K1 -K1 -K1 -K1 -K1


/32.4 /31.4 /31.4 /31.4 /31.4
E1.6 PEW752-
- PEW754- PEW756-
- PEW758-
X12 X11 X11 X11 X11
18

10

13
24V DC
24.9 / L+.A
11.9 / M.K M.K / 28.0

Spare Earth analog Earth analog Earth analog Earth analog

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 27
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K2 -K2 -K2 -K2 -K2 -K2 -K2 -K2 -K3


/33.3 /33.3 /33.3 /33.3 /33.5 /33.5 /33.5 /33.5
PEW256M- PEW258M- PEW260M- PEW262M- PEW264M- PEW266M- PEW268M- PEW270M-
/34.5 /34.5
X1 X1 X1 X1 X1 X1 X1 X1

Mana
6

Mana
10
5

10

15

20

25

30

35

40
27.9 / M.K M.K / 30.0

Earth analog Earth analog Earth analog Earth analog Earth analog Earth analog Earth analog Earth analog Earth analog Earth analog

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 28
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-P1
Button Designation Symbol

Westfalia Separator

OP 177B

ACK

DP/MPI/PPI 1F1B USB


1 2 3 4
ON
POWER DC OFF ● ● ● ●
SC

SC
A

A
B

B
24V

0V

PE

24V DC
11.9 / L+.T MPI_A / 30.0
11.9 / M.T MPI_B / 30.0
-PE

Process display

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator Process display OP 177B
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 29
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K1 CPU 313C


-K2 -K3 -K4
2AO
8AI 8DI/8DO
0005-4050-720 6ES7331-1KF02-0AB0 0005-4281-010 0005-4050-730
6ES7313-5BF03-0AB0 6ES7331-1KF02-0AB0 6ES7332-5HB01-0AB0 6ES7323-1BH01-0AA0
Rack: 1 Rack: 1 Rack: 1
Slot: 4 Slot: 5 Slot: 6
SF GEA
BF Rack: 1
Slot: 1-3
DC5V 0 0 0 0 0
FRCE X11 1 1
X12 1 1
X1 1
RUN
2 2 2 2 2
STOP
3 3 3 3 3
PUSH
4 4 4 4 4
RUN
5 5 5 5 5
STOP
6 6 6 6 6

PEW270M-
PAW754U
PEW758V
MRES

PAW274
7 7 7 7 7

A1.7

A8.7
E2.7

E1.7
IN IN OUT IN IN

-
-
-
-

-
-
E2.0

E0.0
A0.0
PEW752V
PAW752U

PAW272

E8.0
PEW256I
L+ 0 0 0 0
1 1 1 1
M
2 2 2 2
3 3 3 3
4 4 4 4
5 5 5 5
6 6 6 6
7 7 7 7

X1 MPI
A
29.9 / MPI_A
B
29.9 / MPI_B
SC

A
Mana /31.4

B
1L+ /32.4

2L+ /32.5

3L+ /32.5

2L+ /35.5
1L+ /34.5
4M /31.5

1M /32.4

2M /32.5

3M /32.5

1M /35.5

2M /35.5
1M /34.5
SC

DC 24V
L+

X11:20

X11:30

X12:1

X12:20

X12:21

X12:30

X12:31

X12:40

X1:1

X1:20

X1:10

X1:11

X1:20
24V DC
11.9 / L+.K
28.9 / M.K

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC power supply
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 30
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K1

X11:1 X11:21

X11:2 X11:22
PEW752V E2.0 /19.7 =01+HFO1-K11:24 Valve clean-oil discharge limit switch open from HFO1

X11:3 X11:23
Current measuring separator =01-T1:8 /13.3 PEW752I E2.1 /19.8 =01+HFO1-K12:24 Valve clean-oil discharge limit switch closed from HFO1

X11:4 X11:24
Earth analog /27.2 - E2.2

X11:5 X11:25
PEW754V E2.3

X11:6 X11:26
Clean-oil discharge pressure =01-X2:6 /16.1 PEW754I E2.4

X11:7 X11:27
Earth analog /27.3 E2.5

X11:8 X11:28
PEW756V E2.6

X11:9 X11:29
Sludge room monitoring =01-X2:8 /16.2 PEW756I E2.7 /12.8 =0-K1:14 Separator emergency stop

X11:10
Earth analog /27.4 - X11:30
4M /30.3 0V
X11:11
PEW758V V X11:31

X11:12
Product temperature control =11-T1:1 /22.5 PEW758I A
X11:32
X11:13
Earth analog /27.4
X11:33
X11:14
Min / max temperature monitoring =11-X2:3 /22.6 PEW760+
X11:34
PT100
X11:15
Min / max temperature monitoring /22.6 PEW760-
X11:35

X11:16 X11:36
PAW752U

X11:17 X11:37
PAW752I

X11:18 X11:38
PAW754U

X11:19 X11:39
Control valve heating medium positioner =11-X2:7 /22.3 PAW754I

X11:20 X11:40
Mana /30.3 Mana

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 31
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K1

X12:1 X12:21
24V /30.3 1L+ 2L+ /30.3 24V

X12:2 X12:22
Separator operation =01-Q1:34 /14.1 E0.0 A0.0 /18.1 =01-X2:14 Feed valve

X12:3 X12:23
Separator failure =01-F1:22 /14.2 E0.1 A0.1 /18.4 =01-X2:17 Displacem- and filling water

X12:4 X12:24
E0.2 A0.2 /18.3 =01-X2:16 Operating water

X12:5 X12:25
Speed monitoring device =01-T2:4+ /15.2 E0.3 A0.3

X12:6 X12:26
E0.4 A0.4 /18.5 =01-X2:19 Circulation valve

X12:7 X12:27
Water discharge =01-X2:10 /16.3 E0.5 A0.5 /18.6 =01-X2:20 Water discharge valve

X12:8 X12:28
E0.6 A0.6

X12:9 X12:29
LSHH sludge tank from HFO1 =16+HFO1-K4:24 /24.1 E0.7 A0.7 /25.1 =100-K1:A1 Common failure

X12:10 X12:30
2M /30.3 0V

X12:11 X12:31
3L+ /30.4 24V

X12:12 X12:32
Feed pump operation =11-Q1:14 /21.1 E1.0 A1.0 /14.1 =01-K1:A1 Separator start/stop

X12:13 X12:33
Feed pump failure =11-Q1:98 /21.2 E1.1 A1.1 /21.1 =11-K2:A1 Feed pump start / stop

X12:14 X12:34
E1.2 A1.2

X12:15 X12:35
E1.3 A1.3 /25.3 =100-K2:A1 Sludge tank Level high / high alarm

X12:16 X12:36
E1.4 A1.4 /25.4 =100-K3:A1 TAH HFO temperature

X12:17 X12:37
E1.5 A1.5 /25.6 =100-K4:A1 TAL HFO temperature

X12:18 X12:38
Spare =16+HFO1-K4:23 /27.1 E1.6 A1.6

X12:19 X12:39
NAHH separator vibration monitoring =01-X2:13 /17.4 E1.7 A1.7 /19.1 =01-K10:A1 Valve clean-oil discharge

X12:20 X12:40
0V /30.3 1M 3M /30.4 0V

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 32
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K2

X1:1 X1:21
PEW256V PEW264V

X1:2 X1:22
FI flow measuring =11-20_9_009:2 /23.1 PEW256I V V PEW264I

X1:3 X1:23
PEW256S- A A PEW264S-

X1:4 X1:24
PEW256M+ PEW264M+

X1:5 X1:25
Earth analog /28.1 PEW256M- PEW264M- /28.4 Earth analog

X1:6 X1:26
PEW258V PEW266V

X1:7 X1:27
PEW258I V V PEW266I

X1:8 X1:28
PEW258S- A A PEW266S-

X1:9 X1:29
PEW258M+ PEW266M+

X1:10 X1:30
Earth analog /28.2 PEW258M- PEW266M- /28.5 Earth analog

X1:11 X1:31
PEW260V PEW268V

X1:12 X1:32
PEW260I V V PEW268I

X1:13 X1:33
PEW260S- A A PEW268S-

X1:14 X1:34
PEW260M+ PEW268M+

X1:15 X1:35
Earth analog /28.2 PEW260M- PEW268M- /28.6 Earth analog

X1:16 X1:36
PEW262V PEW270V

X1:17 X1:37
PEW262I V V PEW270I

X1:18 X1:38
PEW262S- A A PEW270S-

X1:19 X1:39
PEW262M+ PEW270M+

X1:20 X1:40
Earth analog /28.3 PEW262M- PEW270M- /28.7 Earth analog

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 33
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K3
2AO

X1:1
1L+ /30.5 24V

X1:2

X1:3
PAW272 /26.6 =100-X2:24 Clean-oil discharge pressure

X1:4
S+

X1:5
S-

X1:6
Mana /28.8 Earth analog

X1:7
PAW274 /26.8 =100-X2:26 HFO temperature

X1:8
S+

X1:9
S-

X1:10
Mana /28.8 Earth analog

X1:11

X1:12

X1:13

X1:14

X1:15

X1:16

X1:17

X1:18

X1:19

X1:20
1M /30.6 0V

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 34
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

-K4

X1:1
1L+

X1:2
E8.0 /26.1 =100-X2:19 HFO daily tank level Low control Change to daily tank

X1:3
E8.1 /26.2 =100-X2:21 HFO daily tank level High control Change to settling tank

X1:4
E8.2 /26.4 =100-X2:23 Remote start / stop NO for stop, NC for start

X1:5
E8.3

X1:6
E8.4

X1:7
E8.5

X1:8
E8.6

X1:9
E8.7 /16.6 =01-23_7_020:14 Sludge discharge flap

X1:10
1M /30.6 0V

X1:11
2L+ /30.7 +24V

X1:12
A8.0 /25.7 =100-K5:A1 Local / remote status

X1:13
A8.1 /25.8 =100-K6:A1 PAL clean-oil discharge pressure

X1:14
A8.2

X1:15
A8.3

X1:16
A8.4

X1:17
A8.5

X1:18
A8.6

X1:19
A8.7

X1:20
2M /30.7 0V

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 = 00
Editor GUE/PLE
Customer:
Separator PLC overview
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 35
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EFS 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

600 mm
560 mm 300 mm

-Cabinet ø 8mm -Mountingplate


HFO 2

0-T2
Filter

=00-P1

100-K1
01-K10

100-K2
100-K3
100-K4
100-K5
100-K6
01-K1
11-K2
0-K1

0-F1

01-F1
01-T1
0-F2

01-T2
0-T1

11-T2
1200 mm

1160 mm

01-B1
0-24M

0-Q1

11-Q1
100-X2
01-Q1
=0-Q1
I

O
=0-M1

01-X1

11-X1
01-X2

11-X2

16-X2
0-X1
=00-P1 Process display
=0-M1 Filter / fan
=0-Q1 Isolator Cable glands Size
9x M20 incl. 3x spare 8 - 13mm
10x M25 incl. 3x spare 11 - 17mm
3x M32 incl. 1x spare 15 - 21mm
3x M40 incl. 1x spare 19 - 28mm

Scale 1:7,5 mm Weight: ca. 80kg HFO 2


Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Arrangement drawing control cabinet
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 36
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & ELU 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Control unit E40

Bestell-nr.
0005-4050-700
Westfalia Separator AG
order no.
Programm-Nr.
8106-1E40-768
program-no.

Tiefe: __mm

215
depth:

Ausschnittmass: 228x195mm
cutout dimension:

Gewicht: _,__kg
weight:
ACK

245

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator E40
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 37
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & ELU 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

&EFS/11.6

&EFS/11.6

&EFS/11.6
Cross reference

0V

PE
=00-P1
Target internal

-PE
-T2

Bridges
=0+-24M

Terminal number
1

2
Control voltage DC

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =0+-24M
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 38
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMA 57 Bl./Sh.
=0+-PE

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
=Customer+L-X

Editor
&EFS/10.1

Tested
Incoming PE

PE

PE
-X2_W1

PE
_-J 4x25 mm²
1

-SC

GUE/PLE
Earthing screen PE &EFS/10.3

20.07.2012
SC

SC

07.09.2012/KA
-1M
Earthing mounting plate 1 PE PE &EFS/10.4

PE
-PE

Kunde:
GN/YE

Project:
Projekt:
Customer:
-1T
Earthing door 1 PE PE &EFS/10.4

PE
-PE
2

GN/YE
-1G
Earthing cabinet 1 PE PE &EFS/10.5

Esmeraldas II
PE
-PE

GN/YE
-PE
&EFS/11.1

PDV Power Technology


Control voltage AC PE

= PE &EFS/11.2
-X1 6
3

-M1
= PE &EFS/11.2
PE

L
GN/YE
L

M
1~

PE N
N

-PE

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
&EFS/11.6
4

Separator
Control voltage DC PE

GEA Westfalia
= PE &EFS/11.6
-24M 2

=01-20_1_001
Separator PE &EFS/13.2
PE

=01-X2_W2
PE

_-J 4x16 mm²


U1

T2 U1

Benennung/Description:
V1
5

V1
Θ
M
3~

T1 W1
W1

PE
T2

Terminal connecting plan =0+-PE


T1

=01+HFO1-X2
Spare PE &EFS/19.8
PE

PE

=01-WG021
PE

-PE
6

.-J 7x1 mm²

=16+HFO1-X2
LSHH sludge tank from HFO1 PE &EFS/24.1
PE

PE

=16-WG010
PE

-PE
.-J 3x1 mm²

=01+JB-1X10
Water discharge PE &EFS/16.3
PE =01-X2_W9
PE

.-J 7x1 mm²


&EFS/18.7
PE

Water discharge valve PE


Sprache:
PE:PE PE:PE

=01-X2_W5
PE

Language:
-PE
.-J 7x1 mm²
7

=11-20_3_001
Feed pump PE &EFS/20.1
PE

U1 =11-X2_W3
PE

-PE
_-J 4x2,5 mm²
en
U1

V1
M

W1
V1

PE
Drawing No.:
W1

Zeichnungs Nr.:
8

+DCS-X
Remote start / stop NO for stop, NC for start PE &EFS/26.4
PE

HFO Separator Double Unit (HFO 2)

=100-X2_W20
PE

.-J 7x1,5 mm²


PE

PAL clean-oil discharge pressure PE &EFS/25.9


PE

=100-X2_W19
PE

.-J 18x1,5 mm²


8106-2011-062
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
57 Bl./Sh.
39
0 1 2 3 4 5 6 7 8 9

&EFS/10.3

&EFS/22.6

&EFS/22.3

&EFS/22.4

&EFS/26.8

&EFS/26.8
&EFS/22.7

&EFS/26.7
Cross reference

Target internal -SC

-SC

-SC

-SC

-SC

-SC
Bridges
=0+-SC

SC

SC

SC

SC

SC

SC

SC

SC
Terminal number

PE SC SC SC

PE SC SC SC
-PE

=11-X2

=100-X2

=11-X2

-SC
Control valve heating medium positioner

Min / max temperature monitoring


Product temperature control

Clean-oil discharge pressure


HFO temperature

HFO temperature
Earthing screen

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =0+-SC
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 40
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMA 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

&EFS/11.0

&EFS/11.1

&EFS/11.1

&EFS/11.1

&EFS/11.1

&EFS/11.2

&EFS/12.1

&EFS/12.1

&EFS/12.1
Cross reference

vb

4
=01-X1
Target internal

-F2

-T1
Bridges
=0+-X1

Terminal number
1

9 .-O 2x1 mm²


-X2_W17

RD_U RDWHU GN/YE 1 2


L N PE PE 21 22
N
L

21

M
1~
PE
PE

22
-M1

-PE

-S01
Emergency stop external
Control voltage AC

Control voltage AC
Spare

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =0+-X1
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 41
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMA 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

&EFS/10.1

&EFS/10.1

&EFS/10.1
Cross reference

6
Target internal -Q1

-Q1

-Q1
Bridges
=0+-XQ1

Terminal number
2

6
_-J 4x25 mm²
-X2_W1

1 2 3
L1 L2 L3

L1
=Customer+L-X
Incoming

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =0+-XQ1
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 42
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMA 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

&EFS/13.1

&EFS/13.1

&EFS/13.1

&EFS/13.8
&EFS/13.7
Cross reference

13
Target internal

=0-X1
-Q1

-Q1

-Q1

-F1
Bridges
=01+-X1

Terminal number
1

5
_-J 4x16 mm²
-X2_W2

1 2 3
U1 V1 W1 T2 T1 PE
W1
U1

V1

PE

M
3~
Θ
T2

T1
-20_1_001
Separator

Spare
=

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =01+-X1
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 43
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMA 57 Bl./Sh.
=01+-X2

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
-20_1_001

Editor
&EFS/13.3

Tested
PTC-feeler separator 1

T1
1
-F1 T1
-X2_W13 &EFS/13.3
= .-O 2x1 mm² 2

T2
1

2
T2 U1
-F1 T2

GUE/PLE
20.07.2012
U1
V1

Θ
M
3~

07.09.2012/KA
T1 W1

V1
PE

W1

Kunde:

Project:
Projekt:
PE

Customer:
2

+JB-1X10
Speed monitoring device 3 &EFS/15.2

1
1
-T2 1+
= 4 &EFS/15.2

Esmeraldas II
2
-T2 2-
Clean-oil discharge pressure 5 &EFS/16.1

4
3
=0-T2 L+
&EFS/16.1

PDV Power Technology


= 6

3
4
=00-K1 X11:6

1
-X2_W9 &EFS/16.2
Sludge room monitoring .-J 7x1 mm² 7
3

= 8 &EFS/16.2
6
5

=00-K1 X11:9
Spare 9 &EFS/16.3

Water discharge 10 &EFS/16.3


7
6

=00-K1 X12:7

-23_7_020
Sludge discharge flap 11 &EFS/16.5
13
1

-23_7_020 13
14 13

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
-WG001 &EFS/16.6
4

Separator
= .-O 2x1 mm² 12
14
2

GEA Westfalia
-23_7_020 14

+JB-1X10
NAHH separator vibration monitoring 13 &EFS/17.4
10
1

10

-X2_W5 =00-K1 X12:19


.-J 7x1 mm²

-20_7_006 - +
Feed valve 14 &EFS/18.1
+
1

=00-K1 X12:22
-X2_W4 &EFS/18.1

Benennung/Description:
-

= .-O 2x1 mm² 15


5

=0-24M 1

+JB-1X10
Operating water 16 &EFS/18.3
12
2

=00-K1 X12:24

Terminal connecting plan =01+-X2


Displacem- and filling water 17 &EFS/18.4
15
3

=00-K1 X12:23
= 18 &EFS/18.4
12

-X2_W5 &EFS/18.5
Circulation valve .-J 7x1 mm² 19
16
4

=00-K1 X12:26
6

Water discharge valve 20 &EFS/18.6


18
5

=00-K1 X12:27
= 21 &EFS/18.7
17
6

=11-X2 8

+HFO1-X2
Valve clean-oil discharge to HFO1 22 &EFS/19.6
27
1

-K10 14
= 23 &EFS/19.6
28

Sprache:
2

Language:
-K10 11
7

Valve clean-oil discharge limit switch open from HFO1 24 &EFS/19.7


29
3

=00-K1 X11:22
27

-WG021 &EFS/19.8
Valve clean-oil discharge limit switch closed from HFO1 .-J 7x1 mm² 25
30
4

=00-K1 X11:23
en

+24VDC 26 &EFS/19.8
31
5

=11-X2 5
Spare 27 &EFS/19.8
32
6

Drawing No.:
Zeichnungs Nr.:
8

HFO Separator Double Unit (HFO 2)

8106-2011-062
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
57 Bl./Sh.
44
=01+JB-1X10

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
-29_7_003/B

Editor
&EFS/18.3

Tested
Operating water PE PE

PE
-WG105

PE
-PE
.-J 3x1,5 mm²
1

+SB-1X20

GUE/PLE
PE &EFS/16.3
Water discharge PE

20.07.2012
PE:PE
-WG121

PE
=0-PE PE

PE
.-J 5x1,5 mm²

07.09.2012/KA
-20_9_018
Speed monitoring device - + 1 &EFS/15.2

+
-X2 3

BN

Kunde:
-WG101 &EFS/15.2

Project:
Projekt:
-
= .-O 2x0,34 mm² 2

Customer:
-X2 4

BU
2

+SB-1X20
Clean-oil discharge pressure 3 &EFS/16.1

1
1
-X2 6
= 4 &EFS/16.1

Esmeraldas II
2
-X2 5
= 5 &EFS/16.1

1
-WG121
.-J 5x1,5 mm²
&EFS/16.2

PDV Power Technology


Sludge room monitoring 6

4
3
-X2 8
Water discharge 7 &EFS/16.3

5
4
-X2 10
3

-20_9_020
NAHH separator vibration monitoring 8 &EFS/17.1
1
BN

= 9 &EFS/17.3
3
BK

-WG104 &EFS/17.4
= 10
4

_CY-O 4x0,75 mm²


-X2 13
WH

= 11 &EFS/17.1
2
BU

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
4

Separator
GEA Westfalia
-29_7_003/B
Operating water - + 12 &EFS/18.3
+

-X2 16
BN

-WG105 &EFS/18.3
-

= .-J 3x1,5 mm² 13


BU

-29_7_003/A
- + &EFS/18.4
-

Displacem- and filling water 14


BU

-WG106 &EFS/18.4

Benennung/Description:
= 15
+

.-J 3x1,5 mm²


5

-X2 17
BN

+SB-1X20
Circulation valve 16 &EFS/18.5
8
1

-X2 19
Water discharge valve 17 &EFS/18.7
10
2

-X2 21

Terminal connecting plan =01+JB-1X10


8

-WG122 &EFS/18.6
= .-J 4x1,5 mm² 18
11
3

-X2 20
= PE &EFS/18.7
PE:PE
PE

=0-PE PE
6

-29_7_003/A
Displacem- and filling water PE PE &EFS/18.4
PE

-WG106
PE

-PE
.-J 3x1,5 mm²

Sprache:
Language:
7

en Drawing No.:
Zeichnungs Nr.:
8

HFO Separator Double Unit (HFO 2)

8106-2011-062
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
57 Bl./Sh.
45
=01+SB-1X20

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
-21_9_002

I
1

Editor
&EFS/16.1

Tested
Clean-oil discharge pressure 1

2
+JB-1X10 3

WH
2
-WG201 &EFS/16.1
= 2

1
.-O 2x0,34 mm²
1

+JB-1X10 4

BK

GUE/PLE
20.07.2012

07.09.2012/KA
-20_9_014

I
1 &EFS/16.2
Sludge room monitoring 3

1
BK
2
-WG202 &EFS/16.2
= 4

2
.-O 2x0,34 mm²
+JB-1X10 6

P
WH

Kunde:

Project:
Projekt:
Customer:
-20_9_013
Water discharge 5 &EFS/16.3
+

A/Q
+JB-1X10 7
2

BK
= A/Q 6 &EFS/16.3

+
-WG203

BN
.-O 3x0,75 mm²
- &EFS/16.3

-
= 7

Esmeraldas II
GY
-20_7_010
- + &EFS/18.5

PDV Power Technology


Circulation valve 8

+
+JB-1X10 16

BN
-WG204 &EFS/18.5

-
= .-J 3x0,75 mm² 9

BU
3

-20_7_011
- + &EFS/18.7
-

Water discharge valve 10


+JB-1X10 17
BU

-WG205 &EFS/18.6
= 11
+

.-J 3x0,75 mm²


+JB-1X10 18
BN

-20_7_010
Circulation valve PE PE &EFS/18.6
PE

-WG204
PE

+JB-1X10 PE
.-J 3x0,75 mm²

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
4

Separator
GEA Westfalia
-20_7_011
Water discharge valve PE PE &EFS/18.7
PE

-WG205
PE

+JB-1X10 PE
.-J 3x0,75 mm²

Benennung/Description:
5

Terminal connecting plan =01+SB-1X20


6

Sprache:
Language:
7

en Drawing No.:
Zeichnungs Nr.:
8

HFO Separator Double Unit (HFO 2)

8106-2011-062
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
57 Bl./Sh.
46
0 1 2 3 4 5 6 7 8 9

&EFS/20.1

&EFS/20.1

&EFS/20.1
Cross reference

6
Target internal -Q1

-Q1

-Q1
Bridges
=11+-X1

Terminal number
1

3
_-J 4x2,5 mm²
-X2_W3

1 2 3
U1 V1 W1 PE
W1
U1

V1

PE

M
3
-20_3_001
Feed pump

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =11+-X1
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 47
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMA 57 Bl./Sh.
=11+-X2

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
-20_9_008

Editor
&EFS/22.5

Tested
Product temperature control 1

1
1
-T1 3
= 2 &EFS/22.5

Θ
1

2
2 1 -T1 4

GUE/PLE
-X2_W12 &EFS/22.6
Min / max temperature monitoring 3

3
.CY-O 4x1 mm²

20.07.2012
3
=00-K1 X11:14

07.09.2012/KA
= 4 &EFS/22.6

4
4
=00-K1 X11:15

-X2_W14

Kunde:
&EFS/22.4

Project:
Projekt:
Control valve heating medium positioner SC

SC

Customer:
-X2_W14 =0-SC SC

SC
.CY-O 2x1 mm²
2

-X2_W12
Min / max temperature monitoring SC &EFS/22.7

SC
-X2_W12 =0-SC SC

SC
.CY-O 4x1 mm²

Esmeraldas II
-20_9_009

I
1 &EFS/23.1
FI flow measuring 5

1
1
=01-X2 26
-WG004 &EFS/23.1

PDV Power Technology


= 2 6

2
.-O 2x1 mm²

2
=00-K2 X1:2

P
3

-20_7_012 +
Control valve heating medium positioner 7 &EFS/22.3
+
1

=00-K1 X11:19
-
-X2_W14 &EFS/22.3
-

= .CY-O 2x1 mm² 8


2

=01-X2 21

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
4

Separator
GEA Westfalia Benennung/Description:
5

Terminal connecting plan =11+-X2


6

Sprache:
Language:
7

en Drawing No.:
Zeichnungs Nr.:
8

HFO Separator Double Unit (HFO 2)

8106-2011-062
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
57 Bl./Sh.
48
0 1 2 3 4 5 6 7 8 9

&EFS/24.1

&EFS/24.1
Cross reference

X12:9

2
=00-K1

=11-T1
Target internal

Bridges
=16+-X2

Terminal number
1

2 .-J 3x1 mm²


-WG010

1 2
12 13

12
+HFO1-X2
LSHH sludge tank from HFO1

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Terminal connecting plan =16+-X2
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 49
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMA 57 Bl./Sh.
=100+-X2

Changes
Date
0

Bridges
Target internal

Name
Cross reference

Terminal number

Date
+DCS-X

Editor
&EFS/25.1

Tested
Common failure 1

1
-K1 21
= 2 &EFS/25.1
1

2
-K1 24

GUE/PLE
Separator operation 3 &EFS/25.2

20.07.2012
3
=01-Q1 44

07.09.2012/KA
= 4 &EFS/25.2

4
=01-Q1 43
Sludge tank Level high / high alarm 5 &EFS/25.3

5
-K2 11

Kunde:
&EFS/25.3

Project:
Projekt:
= 6

Customer:
-K2 14
TAH HFO temperature 7 &EFS/25.4

7
-K3 11
2

= 8 &EFS/25.4

8
-K3 14
TAL HFO temperature 9 &EFS/25.6

Esmeraldas II
9
-X2_W19 -K4 11
.-J 18x1,5 mm²
= 10 &EFS/25.6

10
-K4 14
&EFS/25.7

PDV Power Technology


Local / remote status 11

11
-K5 11
= 12 &EFS/25.7

12
-K5 14
3

PAL clean-oil discharge pressure


13
13 &EFS/25.8
-K6 11
= 14 &EFS/25.8
14

-K6 14
= 15 &EFS/25.9
15

= 16 &EFS/25.9
16

= 17 &EFS/25.9
17

© This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved.
&EFS/26.1
4

Separator
HFO daily tank level Low control Change to daily tank 18
1

GEA Westfalia
=11-X2 5
= 19 &EFS/26.1
2

=00-K4 X1:2
HFO daily tank level High control Change to settling tank 20 &EFS/26.2
3

-X2_W20 &EFS/26.2
= .-J 7x1,5 mm² 21
4

=00-K4 X1:3
Remote start / stop NO for stop, NC for start 22 &EFS/26.4
5

&EFS/26.4

Benennung/Description:
= 23
5

=00-K4 X1:4
Clean-oil discharge pressure 24 &EFS/26.6
1

=00-K3 X1:3
= 25 &EFS/26.6
2

=11-X2 8
-X2_W18

Terminal connecting plan =100+-X2


HFO temperature 26 &EFS/26.8
.CY-O 4x1,5 mm²
3

=00-K3 X1:7
= 27 &EFS/26.8
4

= SC &EFS/26.8
=0-SC SC
6

Sprache:
Language:
7

en Drawing No.:
Zeichnungs Nr.:
8

HFO Separator Double Unit (HFO 2)

8106-2011-062
As built +
Rev.05 =

DCC
& EMA
9

Bl./Sh.
57 Bl./Sh.
50
0 1 2 3 4 5 6 7 8 9

Cable layout

Cable name /page.path Source (from) Target (to) Cable type Wires total Wires used Cross-section Length Cable gland / clamping range Remark

=0-X2_W1 &EFS/10.1 =0-PE;=0-XQ1 =Customer+L-X _-J 4x 4 25 mm² M40x1,5 / 19-28mm

=0-X2_W17 &EFS/12.1 =0-X1 =0-S01 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=01-WG001 &EFS/16.5 =01-X2 =01-23_7_020 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=01-WG021 &EFS/19.6 =0-PE;=01-X2 =01+HFO1-X2 .-J 7x 7 1 mm² M25x1,5 / 11-17mm

=01-X2_W2 &EFS/13.1 =0-PE;=01-X1 =01-20_1_001 _-J 4x 4 16 mm² M32x1,5 / 15-21mm

=01-X2_W4 &EFS/18.1 =01-X2 =01-20_7_006 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=01-X2_W5 &EFS/17.4 =0-PE;=01-X2 =01+JB-1X10 .-J 7x 7 1 mm² M25x1,5 / 11-17mm

=01-X2_W9 &EFS/16.1 =0-PE;=01-X2 =01+JB-1X10 .-J 7x 7 1 mm² M25x1,5 / 11-17mm

=01-X2_W13 &EFS/13.3 =01-X2 =01-20_1_001 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=11-WG004 &EFS/23.1 =11-X2 =11-20_9_009 .-O 2x 2 1 mm² M20x1,5 / 8-13mm

=11-X2_W3 &EFS/20.1 =0-PE;=11-X1 =11-20_3_001 _-J 4x 4 2,5 mm² M25x1,5 / 11-17mm

=11-X2_W12 &EFS/22.5 =11-X2 =11-20_9_008 .CY-O 4x 4 1 mm² M25x1,5 / 11-17mm

=11-X2_W14 &EFS/22.3 =11-X2 =11-20_7_012 .CY-O 2x 2 1 mm² M20x1,5 / 8-13mm

=16-WG010 &EFS/24.1 =0-PE;=16-X2 =16+HFO1-X2 .-J 3x 3 1 mm² M25x1,5 / 11-17mm

=100-X2_W18 &EFS/26.6 +DCS-X =100-X2 .CY-O 4x 4 1,5 mm² M25x1,5 / 11-17mm

=100-X2_W19 &EFS/25.1 +DCS-X =100-X2;=0-PE .-J 18x 18 1,5 mm² M40x1,5 / 19-28mm

=100-X2_W20 &EFS/26.1 +DCS-X =100-X2;=0-PE .-J 7x 7 1,5 mm² M32x1,5 / 15-21mm

=01+JB-WG101 &EFS/15.1 =01+JB-1X10 =01-20_9_018 .-O 2x 2 0,34 mm² M12x1,5 / 3-6mm

=01+JB-WG104 &EFS/17.1 =01+JB-1X10 =01-20_9_020 _CY-O 4x 4 0,75 mm² M16x1,5 / 5-10mm

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Cable layout
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 51
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Cable layout

Cable name /page.path Source (from) Target (to) Cable type Wires total Wires used Cross-section Length Cable gland / clamping range Remark

=01+JB-WG105 &EFS/18.3 =01+JB-1X10 =01-29_7_003/B .-J 3x 3 1,5 mm² M16x1,5 / 5-10mm

=01+JB-WG106 &EFS/18.4 =01+JB-1X10 =01-29_7_003/A .-J 3x 3 1,5 mm² M16x1,5 / 5-10mm

=01+JB-WG121 &EFS/16.1 =01+JB-1X10 =01+SB-1X20 .-J 5x 5 1,5 mm² M16x1,5 / 5-10mm

=01+JB-WG122 &EFS/18.5 =01+JB-1X10 =01+SB-1X20 .-J 4x 4 1,5 mm² M16x1,5 / 5-10mm

Integrated in the sensor


=01+SB-WG201 &EFS/16.1 =01+SB-1X20 =01-21_9_002 .-O 2x 2 0,34 mm²
block
Integrated in the sensor
=01+SB-WG202 &EFS/16.2 =01+SB-1X20 =01-20_9_014 .-O 2x 2 0,34 mm²
block
Integrated in the sensor
=01+SB-WG203 &EFS/16.3 =01+SB-1X20 =01-20_9_013 .-O 3x 3 0,75 mm²
block
Integrated in the sensor
=01+SB-WG204 &EFS/18.5 =01+SB-1X20 =01-20_7_010 .-J 3x 3 0,75 mm²
block
Integrated in the sensor
=01+SB-WG205 &EFS/18.6 =01+SB-1X20 =01-20_7_011 .-J 3x 3 0,75 mm²
block

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Cable layout
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 52
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Hinweise zur Installation von Kabeln und Leitungen


Directions for installation from cables and conductors

* Schutzmaßnahmen nach Bestimmungen des VDE bzw. zuständigen EVU ausführen!


All protective measures are to be taken in accordance with electric codes, rules and regulations!
* Generell sind die Vorgaben des lokalen Energieversorgers zwingend einzuhalten
In general the the rules and regulations of the lokal power authorities has to be followed.
* Kabel und Leitungen sind so auszuwählen und zu verlegen, dass eine Gefährdung von Personen und der Umgebung ausgeschlossen ist.
Die angegebenen Kabelquerschnitte sind bezogen auf eine Kabellänge von 50m, Kupfer als Leitematerial, Verlegeart "C" und
eine maximale Umgebungstemperatur von 30°C. Siehe hierzu DIN VDE 0298-4 (Verwendung von Kabeln und isolierten Leitungen für Starkstromanlagen - Teil 4:
Empfohlene Werte für die Strombelastbarkeit von Kabeln und Leitungen für feste Verlegung in und an Gebäuden und von flexiblen Leitungen).
Neben der Strombelastung sind bei der Errichtung von Kabel- und Leitungsanlagen weitere Faktoren zu berücksichtigen.
Siehe hierzu IEC 60364-5-52 (Errichten von Niederspannungsanlagen - Teil 5: Auswahl und Errichtung elektrischer Betriebsmittel - Kapitel 52: Kabel- und Leitungsanlagen)
Cables and lines must be selected and laid in a way to eliminate any risk to persons and the environment.
The cable cross-sections specified in these drawings are based on a max. length of 50m, copper as conducting material,laying version "C" and a maximum ambient temperature of 30°C.
Refer also to DIN VDE 0298-4 (Usage of cables and cords in power installations - Part 4:
Recommended current-carrying capacity for sheathed and nonsheathed cables for fixed wirings in and around buildings and for flexible cables and cords).
Besides the current load are in the erection of wiring systems additional parameters to take into account.
Refer also to IEC 60364-5-52 (Erection of low voltage installations - Part 5: Selection and erection of electrical equipment - Chapter 52: Wiring systems)
* Messleitungen sind grundsätzlich abgeschirmt zu verlegen!
Measuring lines must always be laid shielded!
* WD-Kabel getrennt vom WF-/WG-Kabeln verlegen!
WD-cables to be installed separate from WF-/WG-cable!
* Alle Kabel müssen den Flammentest Anforderungen für gebündelte Kabel nach IEC 60332-3 / IEEE 45-18.13 gerecht werden.
All cables must meet the flame test requirements for bunched cables acc. to IEC 60332-3 / IEEE 45-18.13.
* Das gesamte Kabelmaterial muss halogenfrei nach IEC 60754-1, giftfrei nach IEC 60754 und korrosionsfrei nach IEC 60754-2 sein
All cable materials must be free of halogens acc. to IEC 60754-1, no toxicity acc. to 60754 and no corrosivity acc. to IEC 60754-2.
* Alle Kabel müssen eine Abnahme der relevante Abnahmegesellschaft haben. Isolierungsfestigkeit: 0.6/1KV
All cables must have an approval of the relevant classification society. Insulating strength: 0.6/1KV * GEA WSPN Standard: Nexans MPRX 0.6/1kV.

WD-Kabel Energiekabel < 1kV WE-Kabel Erdungs-/Potentialausgleichsleiterleiter


WD-cable = Energy cable < 1kV WE-cable = Earth-/ Equipotential bonding conductor
WF-Kabel Datenbus WG-Kabel Steuer-/ Messkabel WH-Kabel Lichtwellenleiter
WF-cable = Data bus WG-cable = Control-/measuring cable WH-cable = Optical fibre

* Legende Kabeltypen (Kabelliste)


Legend cable typ (list of cables)

Kabel / Leitung mit Schutzleiter


-J = Cable / conductor with protective conductor FC.CY = Motorkabel FU mit konzentrischem Außenleiter (PE)
Motor cable FC with concentric outer (PE)
Kabel / Leitung ohne Schutzleiter
-O = Cable / conductor without protective conductor PL = Potentialausgleichsleiter
Equipotential bonding conductor
Kabel / Leitung mit Schutzleiter geschirmt
CY-J = Cable / conductor with protective conductor screened Ex-CY = Steuerleitung blau für eigensichere Stromkreise
Control line blue for intrinsically safecircuits
Kabel / Leitung ohne Schutzleiter geschirmt
CY-O = Cable / conductor without protective conductor screened CY-TP = Datenleitung paarverseilt
Data line twisted pair
Motorkabel FU geschirmt mit Schutzleiter
FC.CY-J = Motor cable FC screened with protective conductor

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Instructions for installation
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 53
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

FU
FC

=..-U.
Generelle Information zum Potentialausgleich.
Die Informationen auf diesem Blatt sind nicht
kundenspezifisch angepasst.
IP54

General Information for the equipotential bonding system.


≥10 mm²
GN YE Please note, that the information shown on this page are
not customised.

PE-Schiene
protective earth - rail

IDM

≥25 mm²
GN YE

≥10 mm²
GN YE

PA
PA7

PA6

PA5

PA4

PA3

PA2

PA1

≥10 mm²
GN YE
equipotential bonding building
Potentialausgleich Gebäude

≥25 mm²
GN YE

Fundamenterder
foundation earth

Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Potential equalization Separator
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 54
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EMB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Parts list

Function sign /page.path WS part-no. Manufacturer order no.. Name Manufacturer

=0-Q1 &EFS/10.1 0005-1837-060 LV429631 Compact Leistungsschalter, NSX100F+TM80D 3P3D 56-80A, 36KA/415VAC Groupe Schneider
Compact circuit breaker
=0-Q1 &EFS/10.1 Konsole 90X160X100 Konsole 90X160X100 Konsole verzinkt Zimmermeyer
Bracket zinced
=0-Q1 &EFS/10.1 0005-1438-200 29450 Hilfsschalter OF/SD/SDE/SDV für NS/NSX100..630 Groupe Schneider
auxiliary contact
=0-Q1 &EFS/10.1 0005-1837-160 LV429515 Klemmenabdeckung kurz, 3-polig für NSX100/160/250 Groupe Schneider
Cover of terminals, short
=0-Q1 &EFS/10.1 0005-1837-180 LV429338 Drehantrieb mit Türkupplung für NSX 100...250, Standard, schwarzer Griff Groupe Schneider
Front-rotating drive, black
=0-F1 &EFS/11.1 0005-1872-670 3RV2411-0KA10 Leistungsschalter, 0,9...1,25A, BGR S00, für den Transformatorschutz Siemens
Circuot-breaker, 0.9...1.25A, size S00, transformer protection
=0-F2 &EFS/11.1 0005-1428-000 23732 Sicherungsautomat C 6A, 1 pol, C60N Groupe Schneider
Circuit breaker
=0-M1 &EFS/11.1 0005-1409-390 116 43 10 1 055 Filterlüfter, 207-253V, 50/60Hz, 45/39W, 231/265m³/h Pfannenberg
Filter fan
=0-M1 &EFS/11.1 0005-1409-240 117 40 00 1 055 Austrittsfilter Pfannenberg
Discharge filter
=0-24M &EFS/11.6 0005-4708-890 1031400000 Durchgangs-Reihenklemme, 1,5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 1,5 mm², screw connection, Wemid, dark-beige, TS 35
=0-T1 &EFS/11.1 0005-0551-490 700199 Steuerspannungstransformator, Prim.: 200-560VAC, Sek.: 115/230V, 400VA Ismet
Control voltage transformer, prim.: 200-560 VAC, sec.: 115/230 V, 400 VA
=0-T2 &EFS/11.5 0005-1407-020 6EP1333-2AA01-0AA0 Einphasennetzgeraet Prim.: 120/230V, 50/60Hz, Sec.: 24VDC, 5A Siemens
Single phase power supply
=0-X1 &EFS/11.0.. 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=0-K1 &EFS/12.6 0005-4033-110 2966207 Relais Einzelkontakt,PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Phoenix Contakt
Relay for single contact, PLC interface, miniature relay with power contact, 1 change-over
=0-S01 &EFS/12.1 0005-0081-030 3SB3801-0DF3 Pilzdrucktaster Gehäuse, verrastend, mit Schutzkragen, 1NC, 2x M20 Siemens
Mushroom push button box
=0-S01 &EFS/12.1 0005-4487-930 70-20-060-000-13-041 Verschraubung Polyamid, M20x1,5, RAL 7032, halogenfrei, d=8-13mm Jacob
Screw connection polyamide, M20x1,5, RAL 7032, halogen free, 8-13mm
=0-S01 &EFS/12.1 0013-0132-900 50225 PA7035 Gegenmutter Polyamid, M25x1,5, RAL 7035 Jacob
Counter nut polyamide, M25x1,5, RAL 7035
=01-B1 &EFS/13.1 0005-0924-090 TAID10C100 Stromwandler, 100/1A IME
Current transformer
=01-F1 &EFS/13.4 0005-1100-070 3RN1010-1CM00 THERMISTOR-MOTORSCHUTZ, STANDARD-AUSWERTEGERÄT, AUTO, 1S+1OE, AC 230V Siemens
THERMISTOR MOTOR PROTECTION EVALUATION UNIT AUTO, 1NO+1NC, AC 230V
Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Parts list
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 55
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EPB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Parts list

Function sign /page.path WS part-no. Manufacturer order no.. Name Manufacturer

=01-Q1 &EFS/13.8 0005-4382-270 3RT1044-1AL20 Leistungsschütz, 30KW/400V, 230VAC 50/60HZ, 3POLIG, BGR. S3, SCHRAUBANSCHLUSS Siemens
CONTACTOR, AC-3 30 KW/400 V, AC 230V 50/60HZ 3-POLE, SIZE S3, SCREW
=01-Q1 &EFS/13.8 0005-4399-050 3RH1921-1HA31 HILFSSCHALTERBLOCK, 31, 3S+1OE, DIN EN 50012, 4POLIG, FÜR MOTORSCHÜTZE, BGR. Siemens
AUXILIARY SWITCH BLOCK, 31, 3NO+1NC
=01-Q1 &EFS/13.8 0005-0915-170 3RT1936-1CD00 RC-GLIED, AC 127...240V, UEBERSPANNUNGSBEGRENZER, ZUM AUFSETZEN, BGR. S2, S3 Siemens
RC-ELEMENT, AC 127...240 V, SURGE SUPPRESSOR
=01-T1 &EFS/13.2 0005-3482-070 1073490000 Stromüberwachung, 0...1 A AC/ 0...5 A AC/ 0...10 A AC , 1 , 0(4)...20 mA , 0...10 V , 1 Weidmueller
Current monitoring, 0 - 1 A AC/0 - 5 A AC/0 - 10 A AC, 1, 0(4) - 20 mA , 0 - 10 V , 1 screw
=01-X1 &EFS/13.1 1028800000 1028800000 Durchgangs-Reihenklemme, 35 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal
=01-X1 &EFS/13.7; 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=01-X2 &EFS/13.3; 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=01-K1 &EFS/14.1 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=01-T2 &EFS/15.1 0005-4509-000 KCD2-E2 Sensor-Endstufenklemme, Eingang für NAMUR-Sensoren, 24V DC Speisespannung Pepperl & Fuchs
Converters- Amplifier to convert NAMUR sensor
=01-K10 &EFS/19.1 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=11-Q1 &EFS/20.0 0005-1730-000 LUB12 Motorabgang Grundgerät - 12A AC-43, 440V Groupe Schneider
Motor outlet of basic unit - 12 A AC-43, 440 V
=11-Q1 &EFS/20.0 0005-1730-130 LUCA12FU Steuereinheit Standard LUCA - class 10, 3-12A 110-220V DC/AC Groupe Schneider
Standard control unit LUCA - class 10, 3-12A 110-220V DC/AC
=11-Q1 &EFS/20.0 0005-1730-310 LUA1C20 Hilfsschaltermodul MSS LUA, 2S Groupe Schneider
Aux. switch module, MSS LUA, 2 NO.
=11-X1 &EFS/20.1 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=11-K2 &EFS/21.1 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=11-T1 &EFS/22.5 0005-3482-060 8483680000 Signalwandler/-trenner, 4...20 mA (Stromschleife), Zugfederanschluss Weidmueller
Signal converter/disconnector, 4...20 mA (current loop), Tension clamp connection
=11-X2 &EFS/22.4.. 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=11-X2 &EFS/22.3 0005-3499-890 1020080000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, blau, TS 35 Weidmueller
Feed-through terminal
=16-X2 &EFS/24.1 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Parts list
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 56
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EPB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Parts list

Function sign /page.path WS part-no. Manufacturer order no.. Name Manufacturer

=100-K1 &EFS/25.1 0005-4033-080 2967060 Relais Mehrfachkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 2 Wechsler, Phoenix Contakt
Relay, PLC interface, relay with power contact, 2 change-over contacts, Un=24 VDC
=100-K2 &EFS/25.3 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=100-K3 &EFS/25.4 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=100-K4 &EFS/25.6 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=100-K5 &EFS/25.7 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=100-K6 &EFS/25.8 0005-4033-040 2966171 Relais Einzelkontakt, PLC-Interface, Miniaturrelais mit Leistungskontakt, 1 Wechsler, Un=24 Phoenix Contakt
Relay , PLC interface, relay with power contact, 1 change-over contact, Un=24 VDC
=100-X2 &EFS/25.1.. 0005-3503-890 1020000000 Durchgangs-Reihenklemme, 2.5 mm², Schraubanschluss, Wemid, dunkelbeige, TS 35 Weidmueller
Feed-through terminal block, 2,5 mm², screw connection, Wemid, dark-beige, TS 35
=0-SC &EFS/26.7; 1600480000 1600480000 Klemmbügel für Schirmanschluss, zur Montage auf Sammelschiene 10x3mm Weidmueller
Retaining clip for shield connection
=00-P1 &EFS/29.1 0005-4050-710 6AV6642-5DA10-1AC0 Prozessanzeige OP177B, Farb-Display, 24VDC Siemens
Process display OP177B
=00-P1 &EFS/29.1 6AV6671-1CB00-0AX2 6AV6671-1CB00-0AX2 Speicherkarte, 128 MByte, MMC Siemens
Memory card
=00-K1 &EFS/30.1 0005-4050-720 6ES7313-5BF03-0AB0 Zentralbaugruppe, CPU 313C Siemens
CPU modul
=00-K1 &EFS/30.1 0005-4050-760 6ES7390-1AE80-0AA0 Profilschiene, 480mm Siemens
Profile bar, 480mm
=00-K1 &EFS/30.1 0005-4050-722 6ES7392-1AM00-0AA0 Frontstecker, 40POLIG Siemens
Front connector, 40 PIN
=00-K1 &EFS/30.1 6ES7953-8LG20-0AA0 6ES7953-8LG20-0AA0 Speicherkarte, 128 kByte, MMC Siemens
Memory card, 128 kByte, MMC
=00-K1 &EFS/30.1 6ES7901-0BF00-0AA0 6ES7901-0BF00-0AA0 MPI-Kabel zur Verbindung von SIMATIC S7 und PG über MPI, 5M Siemens
MPI cable
=00-K2 &EFS/30.4 6ES7331-1KF02-0AB0 6ES7331-1KF02-0AB0 Analogbaugruppe Eingang, SM 331, 8AE, 13BIT Siemens
Analog module input, SM 331, 8AI, 13BIT
=00-K2 &EFS/30.4 0005-4050-722 6ES7392-1AM00-0AA0 Frontstecker, 40POLIG Siemens
Front connector, 40 PIN
=00-K3 &EFS/30.5 0005-4281-010 6ES7332-5HB01-0AB0 Analogbaugruppe Ausgang, SM 332, 2AA, U/I, 11/12BIT Siemens
Analog Module Output, SM 332, 2AO, U/I, 11/12BIT
=00-K3 &EFS/30.5 0005-4050-731 6ES7392-1AJ00-0AA0 Frontstecker, 20POLIG Siemens
Front connector, 20 PIN
Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Parts list
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 57
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EPB 57 Bl./Sh.
0 1 2 3 4 5 6 7 8 9

Parts list

Function sign /page.path WS part-no. Manufacturer order no.. Name Manufacturer

=00-K4 &EFS/30.6 0005-4050-730 6ES7323-1BH01-0AA0 Digitalbaugruppe Ein-/Ausgang, SM 323, 8DE/DA, DC 24V, 0.5A Siemens
Digital Module Input/Output, SM 323, 8DI/DO, DC 24V, 0.5A
=00-K4 &EFS/30.6 0005-4050-731 6ES7392-1AJ00-0AA0 Frontstecker, 20POLIG Siemens
Front connector, 20 PIN
-Cabinet &ELU/36.1 1260500 1260500 Kompakt-Schaltschrank AE, lackiert RAL 7035, eintürig mit Montageplatte Rittal
Compact enclosure AE, painted RAL 7035, single door with mounting plate
-Cabinet &ELU/36.1 0005-1412-000 2519000 Türarretierung für das AE Programm Rittal
Door stay for the AE range
-Cabinet &ELU/36.1 RESOPALSCHILD100/13 RESOPALSCHILD100/13 Resopalschild Kaiser
0 0 Resopal plate
-Cabinet &ELU/36.1 8556-9999-000 KLEINMATERIAL Kleinmaterial Schaltschrank Plenge
Incidentals control cabinet
-Cabinet &ELU/36.1 ADERKENNZEICHNUNG ADERKENNZEICHNUNG Aderkennzeichnung Plenge
Wire marking
-Cable_Glands &ELU/36.9 0013-0131-900 50220 PA7035 Gegenmutter Polyamid, M20x1,5, RAL 7035 Jacob
Counter nut polyamide, M20x1,5, RAL 7035
-Cable_Glands &ELU/36.9 0005-4487-930 70-20-060-000-13-041 Verschraubung Polyamid, M20x1,5, RAL 7032, halogenfrei, d=8-13mm Jacob
Screw connection polyamide, M20x1,5, RAL 7032, halogen free, 8-13mm
-Cable_Glands &ELU/36.9 0013-0132-900 50225 PA7035 Gegenmutter Polyamid, M25x1,5, RAL 7035 Jacob
Counter nut polyamide, M25x1,5, RAL 7035
-Cable_Glands &ELU/36.9 0005-4488-930 70-25-060-000-17-041 Verschraubung Polyamid, M25x1,5, RAL 7032, halogenfrei, d=11-17mm Jacob
Screw connection polyamide, M25x1,5, RAL 7032, halogen free, 11-17mm
-Cable_Glands &ELU/36.9 50232-PA7035 50232 PA7035 Gegenmutter Polyamid, M32x1,5, RAL 7035 Jacob
Counter nut polyamide, M32x1,5, RAL 7035
-Cable_Glands &ELU/36.9 0005-4489-930 70-32-060-000-21-041 Verschraubung Polyamid, M32x1,5, RAL 7032, halogenfrei, d=15-21mm Jacob
Screw connection polyamide, M32x1,5, RAL 7032, halogen free, 15-21mm
-Cable_Glands &ELU/36.9 50240-PA7035 50240 PA7035 Gegenmutter Polyamid, M40x1,5, RAL 7035 Jacob
Counter nut polyamide, M40x1,5, RAL 7035
-Cable_Glands &ELU/36.9 0005-4490-930 70-40-060-000-28-041 Verschraubung Polyamid, M40x1,5, RAL 7032, halogenfrei, d=19-28mm Jacob
Screw connection polyamide, M40x1,5, RAL 7032, halogen free, 19-28mm
-Cable_Glands &ELU/36.9 0005-4443-900 81-20-866-0000-04 Blindstopfen Polyamid, M20x1,5, RAL 7035 Jacob
Blanking plug polyamide, M20x1,5, RAL 7035
-Cable_Glands &ELU/36.9 0005-4444-900 81-25-866-0000-04 Blindstopfen Polyamid, M25x1,5, RAL 7035 Jacob
Blanking plug polyamide, M25x1,5, RAL 7035
=Additions &ELU/36.9 0005-1554-000 1646461044 Kabelbezeichnung, polyamid Weidmueller
Cable designation
=Additions &ELU/36.9 8555-9001-200 8555-9001-200 Betriebsanleitung E40, englisch WS Mineraloil Systems
Instruction manual
Date 20.07.2012 Kunde: PDV Power Technology GEA Westfalia Benennung/Description: Rev.05 =
Editor GUE/PLE
Customer:
Separator Parts list
HFO Separator Double Unit (HFO 2) As built +
Projekt:
Tested 07.09.2012/KA Project:
Esmeraldas II Sprache: Zeichnungs Nr.: DCC Bl./Sh. 58
Changes Date Name © This document is COPYRIGHTED by GEA Westfalia Separator Group GmbH. All rights being reserved. Language: en Drawing No.: 8106-2011-062 & EPB 57 Bl./Sh.