Documentos de Académico
Documentos de Profesional
Documentos de Cultura
DIGICEL
TURIN
ID WCDMA AH0247
Document List 1
CONTENT
Document No.:
13/10/2020 A
Site Information 3
DOCUMENTO DE INSTALACION
DE SITIO
Cable Diagram 4
Installation 5
DIGICEL
Verification List 6
Inventory 7
Datos del Sitio:
TURIN
Additional Information 9
2 SITE PLAN
Site Location 153 38-IPB 222 AH0247 Ues A
Floor Plan 193 05-IPB 222 AH0247 Ues A
Elevation & Antenna Plan 153 12-IPB 222 AH0247 Ues A
3 SITE INFORMATION
Configuration Data (RBS) 1/127 04-IPB 222 AH0247 Ues A
Material List 1/127 11-IPB 222 AH0247 Ues A
Dismantling Inventory 1/127 11-IPB 558 Uen A
4 CABLE DIAGRAM
Cable Diagram (Antenna Split Sector) 1/193 18-IPB 222 AH0247 Ues A
Cable Diagram Plas 2/193 18-IPB 222 AH0247 Ues A
Energy Connection 3/193 18-IPB 222 AH0247 Ues A
5 INSTALLATION
Installation Checklist 4/193 19-IPB 222 AH0247 Ues A
6 VERIFICATION LIST
Installation Checklist 2/006 51-FEA 208 524 Ues A
7 INVENTORY
INVENTORY LIST 4/153 11-IPB 222 AH0247 Ues A
9 ADDITIONAL INFORMATION
Abbreviation List 006 51-IPB 222 AH0247 Ues A
Annexes
Este instructivo o cualquier parte de él hace parte de los derechos de propiedad intelectual y know-how de Ericsson, por tanto debe ser utilizado únicamente con el propósito de
proveer los servicios acordados en el contrato suscrito con Ericsson. El contrato aplicable contiene las obligaciones del usuario en caso de expiración o terminación de dicho
contrato. Copyright © 2006, Ericsson AB
Site Location
PLANTA DE SITIO
ACTUAL
TURIN
CLIENTE: DIGICEL EL SALVADOR
INGRESO
PLANTA DE SITIO
PROPUESTA
TURIN
CLIENTE: DIGICEL EL SALVADOR
A B C
ELEVACIÓN DE ANTENAS
ACTUAL
TURIN
CLIENTE: DIGICEL EL SALVADOR
A B C
ELEVACIÓN DE ANTENAS
PROPUESTA
TURIN
CLIENTE: DIGICEL EL SALVADOR
C A
CORTE DE ANTENAS
ACTUAL
TURIN
CLIENTE: DIGICEL EL SALVADOR
C A
CORTE DE ANTENAS
PROPUESTA
TURIN
CLIENTE: DIGICEL EL SALVADOR
Configuration Data (RBS)
3 SWAP
4.1 Escenario de Sitio Sitio Nuevo Split Sector
NOTA: El listado completo de materiales será anexado como MDR, el listado en esta página
contiene únicamente el HW relevante para la implementación
Dismantling Inventory
Prepared (also subject responsible if other) No
Favor llenar el inventario del equipo a desinstalar, esto puede aplicar a Split Sectors en la mayoria de escenarios
sin embargo, el llenado puede aplicar a cualquier otro escenario donde aplique desinstalación de equipos.
SECTOR 1 - 4 WCDMA
ODDI-035R19B-Q
897.2-960MHz 897.2-960MHz
Bandpass Filter Bandpass Filter
4.3-10
Connector
7-16 N-DIN
1m Jumper from
Connector Radio to Filter
RRU S 01 B8 Existente
R2219 B8 Nuevo
SECTOR 1
SECTOR 4
CABLES
TX/RX A
TX/RX B
COMBA KATHREIN MOD NV KATHREIN
ODDI-035R19B-Q 739 686 739 686
GSM GSM
WCDMA
WCDMA WCDMA SECTOR A SECTOR B
SECTOR 2
SECTOR 1 SECTOR 4
R2219 B8 R01 B8
R01 B8 PROPUESTO EXISTENTE
DX1
DX2
EXISTENTE
DX2DX1
DX1 DX2 DX1 DX2 DX1 DX2
PWR
SLF
ERICSSON ERICSSON
FEEDER RBSA RBSB
FEEDER
OPT in
RBSA RBSB RBSA RBSB
ANTA PWR
PWR ANTB OPT in
ANTA
OPT in ANTB JUMPER
ANTA
ANTB JUMPER
MOD NV KATHREIN
739 686
DIAGRAMA DE DISTRIBUCIÓN GSM
DE CABLES BB6630 WCDMA 900 MHz WCDMA
SECTOR C
CONFIGURACIÓN 2+2+2+2 WCDMA SECTOR 3
RADIO 900MHz
DENTRO DE
GABINETE 2116
R01 B8
EXISTENTE
DX2
DX1
DX1 DX2
ERICSSON
1 2 3 4 5 6
RBSA RBSB
FEEDER
PWR
OPT in
ANTA
ANTB JUMPER
SPD EXISTENTE
RBS6101 EXISTENTE
Energy Connection
1 2 3 4
SPDs
BASEBAND 5216
R2219 B8
Sector 4
SPDs CABLES
Existente Cable DC (TFL492325/)
Nuevo (A instalar) CABLE ET20
Installation Checklist
OK | NOK Comments
1 ANTENNA INSTALLATION
SECTOR 1
1.1 Antenna instalation according to SID
1.2 Stable pipe verified
1.3 Verified antenna bracket and proper installation
1.4 Verified proper filter installation
1.5 Radios grounded to grounding bar
1.6 Verified Downtilt (Electrical & Mechanical)
1.7 Azimuth verified
1.8 Check installation, sealing and correct tightening
Of the connectors in antennas
1.9 Verified jumpers installation
1.10 Verified jumper labeling
SECTOR 2
1.1 Antenna instalation according to SID
1.2 Stable pipe verified
1.3 Verified antenna bracket and proper installation
1.4 Verified proper filter installation
1.5 Radios grounded to grounding bar
1.6 Verified Downtilt (Electrical & Mechanical)
1.7 Azimuth verified
1.8 Check installation, sealing and correct tightening
Of the connectors in antennas
1.9 Verified jumpers installation
1.10 Verified jumper labeling
SECTOR 3
1.1
Antenna instalation according to SID
1.2
Stable pipe verified
1.3
Verified antenna bracket and proper installation
1.4
Verified proper filter installation
1.5
Radios grounded to grounding bar
1.6
Verified Downtilt (Electrical & Mechanical)
1.7
Azimuth verified
1.8
Check installation, sealing and correct tightening
Of the connectors in antennas
1.9 Verified jumpers installation
1.10 Verified jumper labeling
2 OPTICAL FIBER ROUTE AND PROPER INSTALLATION
2,.1 Verified non damaged optical fibers
2.2 Check fastening of the conduit trajectory for OIL
2.3 Check sealing of couplers and tube terminators LT
2.4 Check the placement of Tube distribution boxes LT
2.5 Check the OIL surplus arrangement
2.6 Check the OIL at the entrance of the ENC (Roxtec)
Installation Checklist
4 GENERAL
3.12 Sealed conduit Optical fibel and Power Cable
3.13 Sealed Enclosure Roxtec
Checked by Ericsson
Name
Signature Date
Checked by Digicel
Name
Signature Date
Installation Checklist
DIGICEL
TURIN
AH0247
Certificamos que Ericsson a cumplido con la instalación, integración, pruebas y documentación del sitio:
AH0247 TURIN, de acuerdo a los requerimientos de su cliente (DIGICEL) El Salvador
Referencia elaborada con las recomendaciones y documentación especificas del trabajo realizado.
Fecha
Nombre: Nombre:
Firma: Firma:
Digicel Ericsson
INVENTORY LIST
Prepared (also subject responsible if other) No
ABBREVIATION LIST
3G Third Generation
A:DX1/DX2 Duplex antenna 1 and 2 in cell A
ACCU Alternating Current Connection Unit
ALEX Active Library Explorer
AMM Access Module Magazine
ASC Antenna System Controller
ATM Asynchronous Transfer Mode
BB Baseband
BBS Battery Backup System
BFU Battery Fuse Unit
BTF Barra de Tierra Fisica
BTS Base Transceiver Station
CBU1 Control Base Unit
CDU Combining and Distribution Unit
CGO Cama de Guia de Onda
CPU Central Processing Unit
dBm Decibel referred to milliwatt
DC Direct Current
DCCU DC Connection Unit
DCCU BOX DC Connection Unit Box
DDF Digital Distribution Frame
ddTMA Dual Duplex TMA
DDTMA Dual Duplex Tower Mounted Amplifier
DDU DC Distribution Unit
DF Distribution Frame
DHCP Distribution Frame
DRU Dynamic Host Configuration Protocol
DTMA Dual Radio Unit
dTRU Duplex Tower Mounted Amplifier
DXC duplex Transceiver Unit
DXX Digital Cross Connect
EAC Digital Cross Connect
EACU External Alarm Channel
EDGE External Alarm Connection Unit
EDT External Alarm Connection Unit
EMC Enhanced Data rates for GSM Evolution
EMI Electrical Down Tilt
ESB Electromagnetic Compatibility
ESD Electromagnetic Interference
ESB External Synchronization Bus
FCU Fan Control Unit
FTP File Transfer Protocol
FU Filter Unit
GPRS General Packet Radio Service
GPS Global Positioning System
HLR Home Location Register
HLS Higher Layer Scheduling
HMAC Hashed Message Authentication Code
HN Home Network
HO Handover
HP High Power
Abbreviation List
Luis Cano
Aprobado por Rev. Fecha Archivo
Walter Yong A 13/10/2020
Outdoor Directional Twin-beam Antenna
ODDI-035R19B-Q
XX Pol,35°Horizontal Beamwidth
824-960/824-960MHz
19.2/19.2dBi, E-Tilt: 0-10/0-10
Integrated RCU Preliminary Issue
Electrical Specifications
R1 824-960, R2 824-960
Frequency Range (MHz)
824-862 862-894 894-960
Polarization ±45°
Gain (dBi) 18.8 19.0 19.2
Horizontal Beam Centers (°) 28 26 25
Horizontal Beamwidth (°) 37 35 32
Vertical Beamwidth (°) 7.5 7.0 6.5
Electrical Downtilt (°) 0-10 / 0-10
1st Upper Sidelobe Suppression (dB) ≥18 ≥18 ≥18
Front-to-Back Ratio (dB) ≥28 ≥26 ≥25
VSWR ≤1.5:1
Isolation Intra-system (dB) ≥25
Maximum Power per Port (W) 500
IM3 (2x43 dBm Carrier) (dBc) ≤-150
Impedance (Ω) 50
Lightning Protection Direct Ground
RET Specifications
RET type Integrated motor, replaceable
Protocol to CCU/TMA 3GPP / AISG 2.0
Input Voltage Range (V) +10 to +30 DC
Power Consumption (W) ≤1(stand by); ≤5(operating)
Connectors to CCU 8 pin connector, Male, conform to AISG 2.0
Connectors to RCU 8 pin connector, Female, conform to AISG 2.0
Connector Position
504
118
Accessories
Model Quantity Description
BA.K.04.00001 1 Mounting Kit, 0-8°tilt.
Typical Patterns
Azimuth Elevation
Main Features
Electrical Specifications
Frequency: UL:897.2-915MHz
DL:942.2-960MHz
Environmental Specifications
Mechanical Specifications
Outline Drawing: