Está en la página 1de 5

VERIFICACIÓN DE LA PRECISIÓN

DEL MUESTREO

Lugar de inspección: Las Bambas - Matarani Material: Concentrado de cobre


Fecha de inspección: 11/30/2019 OL: 236041-01

A B
Lote R3
x11 x12 x1 R1 x21 x22 x2 R1
01 5.98 5.92 5.95 0.06 6.13 6.11 6.12 0.02 6.04 0.17 Cálculo de desviación
02 6.14 6.11 6.13 0.03 5.96 5.94 5.95 0.02 6.04 0.18 estándar
03 6.17 6.12 6.15 0.05 6.15 6.11 6.13 0.04 6.14 0.01 R1 0.03425
04 5.93 5.96 5.95 0.03 6.05 6.07 6.06 0.02 6.00 0.12 R3 0.08975
05 6.14 6.13 6.14 0.01 6.23 6.28 6.26 0.05 6.20 0.12 〖𝑠 ^2 〗 _1 0.00092
06 5.99 6.03 6.01 0.04 5.94 5.90 5.92 0.04 5.97 0.09 〖𝑠 ^2 〗 _3 0.00633
07 6.13 6.15 6.14 0.02 6.19 6.18 6.19 0.01 6.16 0.04 A( ) 6.86670

08 6.06 6.13 6.10 0.07 6.00 5.99 6.00 0.01 6.05 0.10 〖𝑠 ^2 〗 _𝐴= 〖𝑠 ^2 〗0.00092
_1
09 6.18 6.13 6.16 0.05 6.17 6.15 6.16 0.02 6.16 0.01 𝑠_𝐴 0.03035
10 6.09 6.01 6.05 0.08 6.15 6.18 6.17 0.03 6.11 0.12 〖𝑠 ^2 〗 _𝑆𝑃 0.00587
11 6.28 6.31 6.30 0.03 6.18 6.14 6.16 0.04 6.23 0.14 0.07659
12 6.35 6.32 6.34 0.03 6.23 6.21 6.22 0.02 6.28 0.12 0.00679
13 6.09 6.12 6.11 0.03 6.02 6.01 6.02 0.01 6.06 0.09 0.08238
14 6.16 6.07 6.12 0.09 6.25 6.29 6.27 0.04 6.19 0.16
15 6.10 6.09 6.10 0.01 6.11 6.07 6.09 0.04 6.09 0.00 GL
16 6.04 6.05 6.05 0.01 6.15 6.15 6.15 0.00 6.10 0.11 R1= 0.0343 40
17 6.08 5.99 6.04 0.09 6.07 6.05 6.06 0.02 6.05 0.03 R3= 0.0898 20
18 6.07 5.97 6.02 0.10 5.98 6.00 5.99 0.02 6.01 0.03
19 6.16 6.11 6.14 0.05 6.13 6.15 6.14 0.02 6.14 0.01 Nota: si A < 1.8389 ,es necesario
20 6.10 6.11 6.11 0.01 6.29 6.28 6.29 0.01 6.20 0.18 recopilar mas datos
Promedio 6.11 6.09 6.10 0.0445 6.12 6.11 6.12 0.0240 6.1089 0.0898
Referencia:

CONCLUSIONES La desviación estandar para el muestreo y preparación de muestras sSP es 0.07659%.


La desviación estandar total sT= 0.08238% es menor al valor de la referencia 0.3%

OBSERVACIONES Actas 180973 y 187904


RESPONSABLE: Luis Casas

INS-R-MIN.33
Rev01
F.A.: Mayo 2019
VERIFICACIÓN DE LA PRECISIÓN
DEL MUESTREO

Lugar de inspección: Goldfields - Salaverry Material: Concentrado de cobre


Fecha de inspección: 9/13/2019 OL: 235673 / VE1901440

N° % H2O dif Dif^2


1 8.24 -0.1746 0.0304793403
2 8.5 0.08542 0.0072960069
3 8.42 0.00542 2.934028E-05
4 8.45 0.03542 0.0012543403
5 8.4 -0.0146 0.0002126736
6 8.44 0.02542 0.0006460069
7 8.42 0.00542 2.934028E-05
8 8.43 0.01542 0.0002376736
9 8.37 -0.0446 0.0019876736
10 8.47 0.05542 0.0030710069
11 8.28 -0.1346 0.0181126736
12 8.38 -0.0346 0.0011960069
13 8.29 -0.1246 0.0155210069
14 8.43 0.01542 0.0002376736
15 8.37 -0.0446 0.0019876736
16 8.44 0.02542 0.0006460069
17 8.4 -0.0146 0.0002126736
18 8.39 -0.0246 0.0006043403
19 8.41 -0.0046 2.100694E-05
20 8.41 -0.0046 2.100694E-05
21 8.45 0.03542 0.0012543403
22 8.48 0.06542 0.0042793403
23 8.34 -0.0746 0.0055626736
24 8.42 0.00542 2.934028E-05
25 8.45 0.03542 0.0012543403
26 8.52 0.10542 0.0111126736
27 8.51 0.09542 0.0091043403
28 8.38 -0.0346 0.0011960069
29 8.55 0.13542 0.0183376736
30 8.46 0.04542 0.0020626736
31 8.43 0.01542 0.0002376736
32 8.44 0.02542 0.0006460069
33 8.42 0.00542 2.934028E-05
34 8.29 -0.1246 0.0155210069
35 8.24 -0.1746 0.0304793403
36 8.27 -0.1446 0.0209043403
37 8.45 0.03542 0.0012543403

INS-R-MIN.33
Rev01
F.A.: Mayo 2019
VERIFICACIÓN DE LA PRECISIÓN
DEL MUESTREO

38 8.43 0.01542 0.0002376736


39 8.42 0.00542 2.934028E-05
40 8.56 0.14542 0.0211460069
41 8.23 -0.1846 0.0340710069
42 8.49 0.07542 0.0056876736
43 8.45 0.03542 0.0012543403
44 8.52 0.10542 0.0111126736
45 8.33 -0.0846 0.0071543403
46 8.46 0.04542 0.0020626736
47 8.47 0.05542 0.0030710069
48 8.5 0.08542 0.0072960069
Prom 8.41458
Sum 0.3001916667
S2bi #REF! Referencia:
Sbi #REF! Tabla 3

CONCLUSIONES El valor de la desviación estándar entre incrementos primarios es 0.0668,


menor al valor 0.2%-0.7% de la norma ISO 12743, por lo que podemos decir que
la cantidad de incrementos es adecuada.

RESPONSABLE: Luis Casas

INS-R-MIN.33
Rev01
F.A.: Mayo 2019
VERIFICACIÓN DE LA PRECISIÓN
DEL MUESTREO

Concentrado de cobre
235673 / VE1901440

INS-R-MIN.33
Rev01
F.A.: Mayo 2019
VERIFICACIÓN DE LA PRECISIÓN
DEL MUESTREO

Luis Casas

INS-R-MIN.33
Rev01
F.A.: Mayo 2019

También podría gustarte