Está en la página 1de 7

1407 Ridgeview Drive, Mchenry, IL 60050

Phone: (815) 363-8565, Fax: (815) 363-8633

DESCRIPCION TECNICA
Modelo #: 072-4354-500*
(*)Talla

Producto:
• Chamarra de Material PVC de HiGlo® color Amarillo de alta Resistencia ante Quimicos
• Con broches al frente
• Con guantes de Neopreno color Negro Heavy Duty y Conos para crear el Sello
Hermetico de SealTite
• Costuras Blindadas y Vulcanizadas de alta resistencia
• Disponible en Tallas Xchica hasta el 6X-grande.

Material:
HiGlo (PVC) color Amarillo en una base de Poliester, con Grosor de 19-21 milimetros. Con un
Tiempo de Permeabilidad excediendo los 480 minutos ante Acido Fluorhidrico con una
concentracion de un 48-50%.
• Material PVC Totalmente Lavable en Maquina Industrial
• Totalmente AUTOEXTINGUIBLE
• Altamente Durable
• Altamente Resistente ante una gran variedad de químicos*

*Ver Tabla de Permeabilidad para Pruebas de Quimicos adicionales

Cumplimientos/Certificaciones Generales:
ASTM F739 – Pruebas de permeabilidad ejecutadas bajo estos estandares.
Tiempo de intrucion sobre pasa los 480 minutos ante una concentracion de un 48-50% de Acido
Fluorhidrico, tiempo de intrucion de 47 minutos de un 99% de Hidrogeno de Floruro de
Anhydrio en forma de gas, y tiempo de intrucion de 110 minutos de un 97% de Acido Sulfurico.

ASTM D6413 –Prueba de Flamabilidad: Realizada en este material.

ASTM F903 – Pruebas de Penetración ejecutadas bajo este estándar.

Ver imagen en la siguiente página o nuestro sitio: www.standardsafety.com


MAGILL SERVICES, INC.
450 Century Circle Suite B
Conway, SC 29526

Tel (843) 234-3305 Fax (843) 234-3308


www.magillservices.com
LABORATORY REPORT
QLL 18030
Date: February 8, 2013 Test Report # 130106

Standard Safety Equipment Company


1407 Ridgeview Drive
McHenry, IL 60050

Attention: Lupe Lopez

Subject: One (1) sample tested for flammability according to ASTM D-6413.

Identification: HiGlo – Bright Yellow Material

Testing Completed: February 8, 2013

TEST, UNIT OF MEASURE RESULTS

Flame Resistance
(ASTM D-6413) Warp Fill

After flame, seconds 1.4 1.4


5.3 0.9
0.0 3.6
1.7 2.5
0.0 5.8

Average: 1.7 2.8

Char Length, inches 2.3 2.9


3.4 2.9
2.4 3.0
3.8 2.6
3.3 3.1

Average: 3.0 2.9

This report is for the exclusive use of the client to whom it is addressed and its communication to any others or use of the name
Magill Services, Inc. must receive our prior written approval. This report is applicable only to the sample or samples tested.
MAGILL SERVICES, INC.
Test Report # 130106 Page -2- February 8, 2013

TEST, UNIT OF MEASURE RESULTS

Flame Resistance
(ASTM D-6413) Warp Fill

Afterglow, seconds 0.0 0.0


0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0

Average: 0.0 0.0

No occurrence of melting or dripping was observed.

I certify that the above tests were performed under my supervision in accordance with the specification test
requirements and that the reported test results are true, valid and applicable to the samples tested. I further certify that
these samples are the only samples tested from the lot of components identified above.