Está en la página 1de 9

HOJA DE CALCULO DE MURO DE CONTENCION

MEJORAMIENTO DE SERVICIOS DEL SISTEMA DE AGUA PARA RIEGO TECNIFICADO A NIVEL PARCELARIO EN LOS CENTROS POBLADOS DE
PROYECTO: MUÑ APUCRO Y CHALLHUANI, DISTRITO DE ANCO HUALLO, PROVINCIA DE CHINCHEROS – APURÍMAC. CUI N° 2472802

SECTOR: TAMBO CURUPATA


Pesecif de agua = 1.00 Tn/m3 Pesecif de concreto = 2.40 Tn/m3
Datos de suelo factor de seguridad (Φ ) = 0.900
Angulo de fricc. (Φ ) = 24.50 esfzo a comprec. concr(ƒ`c) : = 210 Kg/ cm2
Coefic. de fricc. (m ) = 0.55 β = 0.85
δespecif suelo = 1.77 Tn/m3 esfzo de fluencia de acero (ƒ`y) = 4200 Kg/ cm2
БT(capac. Port S.) = 1.35 kg/Cm2 Largo = 100.00 cm
hp = 4.35 m Recubrimiento en pantalla (r) = 5.00 cm
hp' = 2.10 m Recubrimiento en zapata (r) = 7.50 cm
Peralte muro dm = 25.00 cm
S/C
t1≤0.30 m Peralte en zapata dz = 32.50 cm
Sobre carga = 0.00 Tn/m2
Calculos de Predimensionamiento
t1 = 0.30 m 0.30 m
hz = 0.05 m 0.40 m
H= 4.40 m 4.75 m
tp = 0.35 m 0.30 m
P5 B= 2.85 m 2.85 m
4.20 m B1 = 0.95 m 2.00 m
P4 B2 = 1.90 m 0.85 m
Agua E(losa) = 0.15 m 0.15 m
hp Borde Libre = 0.20 m 0.20 m
P2 H H' = 2.50 m 2.00 m

B1=B/3 Sobrecarga q: La altura de relleno equivalente a sobrecarga vehicular, se tomó siguiendo las recomendaciones de la norma AASHTO 2002
B2=2B/3
losa E=0.15 m 0.15 m
P3 Altura de muro (H) Hs
2.50 m
hz=0.10H-0.12H tp=0.1H-0.12H ≤1.53 m 1.68 m
0.40 m 3.05 m 1.22 m
PUNTA P1 TALON
6.10 m 0.76 m
P6 0.00 m ≥9.15 m 0.61 m

B=0.5H - 0.7H
1.8500 m 0.30 m 0.7000 m

VERIFICACION DE ALTURA DE CIMENTACION

d=√(2𝑀/𝑘𝑗𝑏𝑓𝑐) k=𝑛/ n=𝐸 fs=[0.4−0.5]𝑓𝑦 ; fy=[0.4−0.5]𝑓𝑐 j=1- fc=0.40f'175kg/cm


(𝑛+𝑟)=𝑛/ 𝑠/𝐸𝑐 𝑘/3
(𝑛+𝑓𝑠/𝑓𝑦)
Es= 2*10^6 2,000,000.00 n= 10.08 j= 0.90
Ec= 15000*(175)^0.5 198,431.35 k= 0.30 fc= 70.00

d= 29.91 =tp-5 tp= 0.35


ALTURA DE CIMENTACION

hc= 5.35 = 0.05 m

I .- DETERMINACIÓN DE FUERZAS (VERTICAL, HORIZONTAL) Y MOMENTOS ACTUANTES Y RESISTENTES


"Ea"=1/2∗γ_"Espec.suelo" "∗" "H" ^2 "∗" "K" _a
Cálculo del momento de volteo Mr con respecto al punto x debido al suelo
Punto Descripcion Peso (Tn) X(m) Mr (Tn-m)
P1 Peso Concreto Armado 2.74 1.43 3.90
P2 Peso Concreto Armado 3.13 2.00 6.26 Ka = 0.41
P3 Peso Concreto Armado 0.67 0.93 0.62 𝐸_𝐻2𝑂=1/2∗γ_𝐻2𝑂
P4 Peso Relleño 2.60 2.50 6.50
"∗" "H" ^2
P5 Peso Agua 7.40 0.93 6.85
P6 Peso Concreto Armado 0.00 1.23 0.00
Reservorio lleno Total 16.54 24.13
Reservorio vacio Total 9.14 17.28
"Para suelo horizontal"
Cálculo del momento de vuelco Mv debido a la presión activa y sobre carga Ms=Es*H/2
Punto Descripcion Peso (Tn) X(m) Mv (Tn-m) K_a=["ta" "n" ^2 (45−𝜑/2)]
Ea Empuje activo 1.46 1.58 2.32
Es Sobre Carga 0.00 0.00 0.00
EH2O Empuje de agua 8.00 1.33 10.67 Ma=Ea*H/3
Reservorio lleno Total 6.54 8.35
Reservorio vacio Total 1.46 2.32
II .- VERIFICACIÓN DE LA ESTABILIDAD

1.- Coeficiente de Seguridad al Deslizamient C.S.D (1.5) 2.- Coeficiente de Seguridad al Volteo C.S.V (1.75)
𝐶.𝑆.𝑉=𝑀𝑟/𝑀𝑣 →┴(  )(1.5)
𝐶.𝑆.𝐷=Σ𝐹𝑣/Σ𝐹ℎ →┴(  )(1.5)

C.S.D (R. lleno) = 2.53 OK C.S.V (R. lleno) = 2.89 OK

C.S.D (R. vacio) = 6.24 OK C.S.V (R. vacio) = 7.45 OK

3.- Coeficiente de Seguridad al Hundimiento :


Determinacion de la excentrecidad

X_CG=(Mr−Mv)/Fv e = B/2 − X_CG


e <B/6

Reservorio lleno Reservorio vacio


XCG = 0.954 m XCG = 1.64 m
e = 0.471 m e = -0.2130 m
OK OK
Debe de cumplir lo siguiente :

〖𝛿 Σ𝐹𝑣/𝐿_(𝑜𝑛𝑔.𝑏𝑎𝑠𝑒) [1+6𝑒/𝐿_(𝑜𝑛𝑔.𝑏𝑎𝑠𝑒) ] 〗 _max

〖𝛿 Σ𝐹𝑣/𝐿_(𝑜𝑛𝑔.𝑏𝑎𝑠𝑒) [1−6𝑒/𝐿_(𝑜𝑛𝑔.𝑏𝑎𝑠𝑒) ] 〗 _min Reservorio lleno Reservorio vacio


0.64 < 1.35 0.18 < 1.35
0.00 < 1.35 0.46 < 1.35
𝛿=𝐶 arg⁡𝑎.𝑜𝑐𝑎𝑠𝑖𝑜𝑛𝑎𝑑𝑎.𝑝𝑜𝑟 𝑒𝑠𝑡𝑟𝑢𝑐𝑡𝑢𝑟𝑎𝑠 𝑜𝑡𝑟𝑜𝑠 Ok Ok

III .- DETERMINACIÓN DE MOMENTO ULTIMO Y ACEROS SEGÚN EL COMPORTAMIENTO EN LA PANTALLA

Cálculo del momento de vuelco Mv debido a la presión activa y sobre carga "Ea"=1/2∗γ_"Espec.suelo" "∗h" "p" ^2 "∗" "K" _a
Punto Descripcion Peso (Tn) X(m) Mv (Tn-m)
Ea Empuje activo 1.61 1.58 2.56
SC Sobre Carga 0.00 0.00 0.00 𝑀_𝑢=1.7𝑀
EH2O Empuje de agua 8.00 1.33 10.67
Reservorio lleno Total 6.39 8.11 Mu( - ) = 13.79 Tn-m
Reservorio vacio Total 1.61 2.56
Diseño de acero vertical
a.- Diseño de armadura en pantalla por falla a flexion de acero principal

AS 16.21 15.79 15.76 15.76 15.76 15.76 15.76


a 3.81 3.72 3.71 3.71 3.71 3.71 3.71

As = 15.758 cm2

b.- Diseño de armadura en pantalla por falla a flexion de acero montante

As m  30%As Mu( - )/2 = 6.89 Tn-m


2.89 0.12
Asm = 4.727 cm2 Hc= 1.48 m
Hcr= 1.73 m
Comparacion con acero minimo
As minimos verticales
A  0 . 0018 * b * d
s.minimo
As minimo = 4.500 cm2 Acero estructural principal cara interior = 15.758 cm2
Acero montante cara exterior = 4.727 cm2

Refuerzo horizontal 1 2
Asi  ASt Ase  ASt
Acero de temperatura 3 3

𝜑<5/8»𝜌=0.002
Acero superior Acero superior interior Acero superior exterior
Ast = 5.000 cm2 Ast = 1.667 cm2 Ast = 3.333 cm2

Acero intermedio Acero intermedio interior Acero intermedio exterior


𝜑>5/8»𝜌=0.0025
Ast = 5.500 cm2 Ast = 1.833 cm2 Ast = 3.667 cm2

Acero inferior Acero inferior interior Acero inferior exterior


A s.minimo  0.002 * b * d Ast = 6.000 cm2 Ast = 2.000 cm2 Ast = 4.000 cm2
El espaciamiento de acero esta en funcion a un multiplo de 2,5 inferior solo toma valores siguientes: 2,5 5, 7,5, 10, 12,5, 15, 17,5, 20 etc

Refuerzo acero horizontales


Refuerzo acero verticales
Acero interior Acero exterior
N° Φ de acero AREA ACERO (Cm2) Peso (kg/ml) Aprinc. Amont. Asup Aint Ainf Asup Aint Ainf
3 3/8" 0.71 0.560 2.5 cm 15.0 cm 42.5 cm 37.5 cm 35.0 cm 20.0 cm 17.5 cm 17.5 cm
4 1/2" 1.29 0.994 7.5 cm 25.0 cm 75.0 cm 70.0 cm 62.5 cm 37.5 cm 35.0 cm 30.0 cm
5 5/8" 1.99 1.552 12.5 cm 40.0 cm 117.5 cm 107.5 cm 97.5 cm 57.5 cm 52.5 cm 47.5 cm
6 3/4" 2.84 2.235 17.5 cm 60.0 cm 170.0 cm 152.5 cm 140.0 cm 85.0 cm 75.0 cm 70.0 cm
8 1" 5.1 3.973 30.0 cm 107.5 cm 305.0 cm 277.5 cm 255.0 cm 152.5 cm 137.5 cm 127.5 cm
11 1 3/8" 10.06 7.907 62.5 cm 212.5 cm 602.5 cm 547.5 cm 502.5 cm 300.0 cm 272.5 cm 250.0 cm

IV .- DETERMINACIÓN DE MOMENTO ULTIMO Y ACEROS SEGÚN EN LA PUNTA Y TALÓN

Presiones que actuan


Hallamos ampliacion de cargas 1.85 m 0.30 m 0.70 m

Б1 = 6.38
БA = 2.26 Punta 0.03 Tn/m2
БB = 1.59
𝛿𝐴=2.26 Tn/m2 𝛿𝐵= 1.59 Tn/m2
Б2 = 0.03 6.38 Tn/m2 Talon
6.35 Tn/m2

1 A B 2
Analisis Diseño de punta 1.85 m
Amplificacomos las cargas por un factor de 1.7

Бu1 = 10.85 Tn/m2 AS 11.09 10.40 10.37 10.37 10.37


БuA = 3.84 Tn/m2 a 2.61 2.45 2.44 2.44 2.44 6.38 Tn/m2 2.26 Tn/m2

Amplicamos momento en punto A As = 10.37 cm2


MUA = 12.26
1 A
Comparacion con acero minimo
As minimos verticales 0.70 m
A  0 . 0018 * b * d
s.minimo Acero estructural 10.369 cm2
As minimo = 5.850 cm2 0.03 Tn/m2
1.59 Tn/m2
Analisis Diseño de Talon
БuB = 2.70 Tn/m2
Бu2 = 0.05 Tn/m2
Amplicamos momento en punto B
MUB = 2.35
AS 2.12 2.12 2.12 2.12 2.12
a 0.50 0.50 0.50 0.50 0.50

Comparacion con acero minimo As = 2.12 cm2


As minimos verticales

A  0 . 0018 * b * d
s.minimo Acero estructural 5.850 cm2
As minimo = 5.850 cm2
Calculo de acero transversal
A  0 . 0018 * b * d As minimo = 5.850 cm2 Acero transversal 5.850 cm2
s.minimo
El espaciamiento de acero esta en funcion a un multiplo de 2,5 inferior solo toma valores siguientes: 2,5 5, 7,5, 10, 12,5, 15, 17,5, 20 etc

Refuerzo acero longitudinal Refuerzo acero Transversal

N° Φ de acero AREA ACERO (Cm2) Peso (kg/ml) Punta Talon Punta Talon
3 3/8" 0.71 0.560 5.0 cm 10.0 cm 10.0 cm 10.0 cm
4 1/2" 1.29 0.994 10.0 cm 20.0 cm 20.0 cm 20.0 cm
5 5/8" 1.99 1.552 17.5 cm 32.5 cm 32.5 cm 32.5 cm
6 3/4" 2.84 2.235 25.0 cm 47.5 cm 47.5 cm 47.5 cm
8 1" 5.1 3.973 47.5 cm 85.0 cm 85.0 cm 85.0 cm
11 1 3/8" 10.06 7.907 95.0 cm 170.0 cm 170.0 cm 170.0 cm

IV .- DE REFUERZO POR CONTRACCIÓN Y POR TEMPERATURA PARA LOSA

As minimos para losa


Refuerzo acero
N° Φ de acero AREA ACERO (Cm2) Peso (kg/ml) Long. Transv.
3 3/8" 0.71 0.560 25.0 cm 25.0 cm
4 1/2" 1.29 0.994 47.5 cm 47.5 cm
As minimo = 2.700 cm2
5 5/8" 1.99 1.552 72.5 cm 72.5 cm
6 3/4" 2.84 2.235 105.0 cm 105.0 cm
8 1" 5.1 3.973 187.5 cm 187.5 cm
11 1 3/8" 10.06 7.907 372.5 cm 372.5 cm
F'c= 210 Kg/Cm2
ρb Ku
0.0001 0.378
0.0002 0.754
0.0003 1.13
0.0004 1.505
0.0005 1.879
0.0006 2.252
0.0007 2.624
0.0008 2.995
0.0009 3.366
0.001 3.735
0.0011 4.104
0.0012 4.472
0.0013 4.839
0.0014 5.205
0.0015 5.57
0.0016 5.934
0.0017 6.297
0.0018 6.659
0.0019 7.021
0.002 7.382
0.0021 7.741
0.0022 8.1
0.0023 8.458
0.0024 8.815
0.0025 9.171
0.0026 9.526
0.0027 9.881
0.0028 10.234
0.0029 10.587
0.003 10.939
0.0031 11.289
0.0032 11.639
0.0033 11.988
0.0034 12.336
0.0035 12.684
0.0036 13.03
0.0037 13.375
0.0038 13.72
0.0039 14.064
0.004 14.406
0.0041 14.748
0.0042 15.089
0.0043 15.429
0.0044 15.768
0.0045 16.107
0.0046 16.444
0.0047 16.781
0.0048 17.116
0.0049 17.451
0.005 17.785
0.0051 18.118
0.0052 18.45
0.0053 18.781
0.0054 19.111
0.0055 19.441
0.0056 19.769
0.0057 20.097
0.0058 20.424
0.0059 20.749
0.006 21.074
0.0061 21.398
0.0062 21.721
0.0063 22.044
0.0064 22.365
0.0065 22.685
0.0066 23.005
0.0067 23.324
0.0068 23.642
0.0069 23.958
0.007 24.274
0.0071 24.59
0.0072 24.904
0.0073 25.217
0.0074 25.529
0.0075 25.841
0.0076 26.152
0.0077 26.461
0.0078 26.77
0.0079 27.078
0.008 27.385
0.0081 27.692
0.0082 27.997
0.0083 28.301
0.0084 28.605
0.0085 28.907
0.0086 29.209
0.0087 29.51
0.0088 29.81
0.0089 30.109
0.009 30.407
0.0091 30.704
0.0092 31.001
0.0093 31.296
0.0094 31.591
0.0095 31.884
0.0096 32.177
0.0097 32.469
0.0098 32.76
0.0099 33.05
0.01 33.34
0.0101 33.628
0.0102 33.915
0.0103 34.202
0.0104 34.488
0.0105 34.772
0.0106 35.056
0.0107 35.339
0.0108 35.621
0.0109 35.903
0.011 36.183
0.0111 36.462
0.0112 36.741
0.0113 37.019
0.0114 37.295
0.0115 37.571
0.0116 37.846
0.0117 38.12
0.0118 38.393
0.0119 38.666
0.012 38.937
0.0121 39.208
0.0122 39.477
0.0123 39.746
0.0124 40.014
0.0125 40.281
0.0126 40.547
0.0127 40.812
0.0128 41.076
0.0129 41.339
0.013 41.602
0.0131 41.864
0.0132 42.124
0.0133 42.384
0.0134 42.643
0.0135 42.901
0.0136 43.158
0.0137 43.414
0.0138 43.67
0.0139 43.924
0.014 44.178
0.0141 44.43
0.0142 44.682
0.0143 44.933
0.0144 45.183
0.0145 45.432
0.0146 45.68
0.0147 45.928
0.0148 46.174
0.0149 46.419
0.015 46.664
0.0151 46.908
0.0152 47.151
0.0153 47.393
0.0154 47.634
0.0155 47.874
0.0156 48.113
0.0157 48.352
0.0158 48.589
0.0159 48.826
HOJA DE CALCULO DE MURO DE CONTENCION
MEJORAMIENTO DEL SERVICIO DE AGUA PARA RIEGO DEL COMITE DE USUARIOS DE LATUYOCC DEL DISTRITO DE ROCCHACC - PROVINCIA DE
PROYECTO: CHINCHEROS - DEPARTAMENTO DE APURÍMAC

SECTOR: MURO LONGITUDINAL TALUD INFERIOR


Pesecif de agua = 1.00 Tn/m3 Pesecif de concreto = 2.40 Tn/m3
Datos de suelo factor de seguridad (Φ ) = 0.900
Angulo de fricc. (Φ ) = 28.01 esfzo a comprec. concr(ƒ`c) : = 210 Kg/ cm2
Coefic. de fricc. (m ) = 0.45 β = 0.85
δespecif suelo = 1.67 Tn/m3 esfzo de fluencia de acero (ƒ`y) = 4200 Kg/ cm2
БT(capac. Port S.) = 1.65 kg/Cm2 Largo = 100.00 cm
hp = 3.80 m Recubrimiento en pantalla (r) = 5.00 cm
Recubrimiento en zapata (r) = 7.50 cm
Peralte muro dm = 25.00 cm
S/C
t1≤0.30 m Peralte en zapata dz = 27.50 cm
Sobre carga = 0.00 Tn/m2
Calculos de Predimensionamiento
t1 = 0.25 m 0.30 m
hz = 0.54 m 0.35 m
H= 4.34 m 4.15 m
tp = 0.43 m 0.30 m
P5 B= 2.39 m 2.25 m
3.65 m B1 = 0.80 m 1.85 m
B2 = 1.59 m 0.40 m
Agua E(losa) = 0.15 m 0.15 m
hp Borde Libre = 0.20 m 0.20 m
P2 H
Sobrecarga q: La altura de relleno equivalente a sobrecarga vehicular, se tomó siguiendo las recomendaciones de la norma AASHTO 2002
P4
hr=1.60 m
B1=B/3 B2=2B/3
losa E=0.15m 0.15 m
P3 Altura de muro (H) Hs

hz=hp/5-hp/7 tp=0.1H-0.12H ≤1.53 m 1.68 m


0.35 m 3.05 m 1.22 m
PUNTA P1 TALON
6.10 m 0.76 m
B=0.5H - 0.7H ≥9.15 m 0.61 m

1.7000 m 0.30 m 0.2500 m

I .- DETERMINACIÓN DE FUERZAS (VERTICAL, HORIZONTAL) Y MOMENTOS ACTUANTES Y RESISTENTES


"Ea"=1/2∗γ_"Espec.suelo" "∗" "H" ^2 "∗" "K" _a
Cálculo del momento de volteo Mr con respecto al punto x debido al suelo
Punto Descripcion Peso (Tn) X(m) Mr (Tn-m)
P1 Peso Concreto Armado 1.89 1.13 2.13
P2 Peso Concreto Armado 2.74 1.85 5.06 Ka = 0.36
P3 Peso Concreto Armado 0.61 0.85 0.52 𝐸_𝐻2𝑂=1/2∗γ_𝐻2𝑂
P4 Peso Relleño 0.67 2.13 1.42
"∗" "H" ^2
P5 Peso Agua 5.87 0.85 4.99
Reservorio lleno Total 11.77 14.11
Reservorio vacio Total 5.91 9.13 K_a=["ta" "n" ^2 (45−𝜑/2)]
"Para suelo horizontal" Ms=Es*H/2
Cálculo del momento de vuelco Mv debido a la presión activa y sobre carga
Punto Descripcion Peso (Tn) X(m) Mv (Tn-m)
Ea Empuje activo 1.15 1.38 1.59
Es Sobre Carga 0.00 0.00 0.00
EH2O Empuje de agua 5.95 1.15 6.84 Ma=Ea*H/3
Reservorio lleno Total 4.81 5.26
Reservorio vacio Total 1.15 1.59
II .- VERIFICACIÓN DE LA ESTABILIDAD

1.- Coeficiente de Seguridad al Deslizamient C.S.D (1.5) 2.- Coeficiente de Seguridad al Volteo C.S.V (1.75)
𝐶.𝑆.𝑉=𝑀𝑟/𝑀𝑣 →┴(  )(1.75)
𝐶.𝑆.𝐷=Σ𝐹𝑣/Σ𝐹ℎ∗μ→┴(  )(1.5)

C.S.D (R. lleno) = 2.45 OK C.S.V (R. lleno) = 2.68 OK

C.S.D (R. vacio) = 5.15 OK C.S.V (R. vacio) = 5.76 OK

3.- Coeficiente de Seguridad al Hundimiento :


Determinacion de la excentrecidad

X_CG=(Mr−Mv)/Fv e = B/2 − X_CG


e <B/6

Reservorio lleno Reservorio vacio


XCG = 0.75 m XCG = 1.28 m
e = 0.37 m e = -0.1521 m
OK OK
Debe de cumplir lo siguiente : 0.38 m

〖𝛿 Σ𝐹𝑣/𝐿_(𝑜𝑛𝑔.𝑏𝑎𝑠𝑒) [1+6𝑒/𝐿_(𝑜𝑛𝑔.𝑏𝑎𝑠𝑒) ] 〗 _max

〖𝛿 Σ𝐹𝑣/𝐿_(𝑜𝑛𝑔.𝑏𝑎𝑠𝑒) [1−6𝑒/𝐿_(𝑜𝑛𝑔.𝑏𝑎𝑠𝑒) ] 〗 _min Reservorio lleno Reservorio vacio


0.52 < 1.65 0.16 < 1.65
0.00 < 1.65 0.37 < 1.65
𝛿=𝐶 arg⁡𝑎.𝑜𝑐𝑎𝑠𝑖𝑜𝑛𝑎𝑑𝑎.𝑝𝑜𝑟 𝑒𝑠𝑡𝑟𝑢𝑐𝑡𝑢𝑟𝑎𝑠 𝑜𝑡𝑟𝑜𝑠 Ok Ok

III .- DETERMINACIÓN DE MOMENTO ULTIMO Y ACEROS SEGÚN EL COMPORTAMIENTO EN LA PANTALLA

Cálculo del momento de vuelco Mv debido a la presión activa y sobre carga "Ea"=1/2∗γ_"Espec.suelo" "∗h" "p" ^2 "∗" "K" _a
Punto Descripcion Peso (Tn) X(m) Mv (Tn-m)
Ea Empuje activo 0.77 1.38 1.07
SC Sobre Carga 0.00 0.00 0.00 𝑀_𝑢=1.7𝑀
EH2O Empuje de agua 5.95 1.15 6.84
Reservorio lleno Total 5.18 5.78 Mu( - ) = 9.82 Tn-m
Reservorio vacio Total 0.77 1.07
Diseño de acero vertical
a.- Diseño de armadura en pantalla por falla a flexion de acero principal

AS 11.55 10.99 10.96 10.96 10.96 10.96 10.96


a 2.72 2.59 2.58 2.58 2.58 2.58 2.58

As = 10.957 cm2

b.- Diseño de armadura en pantalla por falla a flexion de acero montante

As m  30%As Mu( - )/2 = 4.91 Tn-m


2.89 0.10
Asm = 3.287 cm2 Hc= 0.74 m
Hcr= 0.99 m
Comparacion con acero minimo
As minimos verticales
A  0 . 0018 * b * d
s.minimo
As minimo = 4.500 cm2 Acero estructural principal cara interior = 10.957 cm2
Acero montante cara exterior = 4.500 cm2

Refuerzo horizontal 1 2
Asi  ASt Ase  ASt
3 3
Acero de temperatura

𝜑<5/8»𝜌=0.002
Acero superior Acero superior interior Acero superior exterior
Ast = 4.000 cm2 Ast = 1.333 cm2 Ast = 2.667 cm2

Acero intermedio Acero intermedio interior Acero intermedio exterior


𝜑>5/8»𝜌=0.0025
Ast = 5.843 cm2 Ast = 1.948 cm2 Ast = 3.895 cm2

Acero inferior Acero inferior interior Acero inferior exterior


A s.minimo  0.002 * b * d Ast = 7.686 cm2 Ast = 2.562 cm2 Ast = 5.124 cm2
El espaciamiento de acero esta en funcion a un multiplo de 2,5 inferior solo toma valores siguientes: 2,5 5, 7,5, 10, 12,5, 15, 17,5, 20 etc

Refuerzo acero horizontales


Refuerzo acero verticales
Acero interior Acero exterior
N° Φ de acero AREA ACERO (Cm2) Peso (kg/ml) Aprinc. Amont. Asup Aint Ainf Asup Aint Ainf
3 3/8" 0.71 0.560 5.0 cm 15.0 cm 52.5 cm 35.0 cm 27.5 cm 25.0 cm 17.5 cm 12.5 cm
4 1/2" 1.29 0.994 10.0 cm 27.5 cm 95.0 cm 65.0 cm 50.0 cm 47.5 cm 32.5 cm 25.0 cm
5 5/8" 1.99 1.552 17.5 cm 42.5 cm 147.5 cm 100.0 cm 77.5 cm 72.5 cm 50.0 cm 37.5 cm
6 3/4" 2.84 2.235 25.0 cm 62.5 cm 212.5 cm 145.0 cm 110.0 cm 105.0 cm 72.5 cm 55.0 cm
8 1" 5.1 3.973 45.0 cm 112.5 cm 382.5 cm 260.0 cm 197.5 cm 190.0 cm 130.0 cm 97.5 cm
11 1 3/8" 10.06 7.907 90.0 cm 222.5 cm 752.5 cm 515.0 cm 392.5 cm 375.0 cm 257.5 cm 195.0 cm

IV .- DETERMINACIÓN DE MOMENTO ULTIMO Y ACEROS SEGÚN EN LA PUNTA Y TALÓN

Presiones que actuan


Hallamos ampliacion de cargas 1.70 m 0.30 m 0.25 m

Б1 = 5.23
БA = 1.52 Punta 0.02 Tn/m2
БB = 0.86
𝛿𝐴=1.52 Tn/m2 𝛿𝐵= 0.86 Tn/m2
Б2 = 0.02 5.23 Tn/m2 Talon
5.22 Tn/m2

1 A B 2
Analisis Diseño de punta 1.70 m
Amplificacomos las cargas por un factor de 1.7

Бu1 = 8.90 Tn/m2 AS 6.05 5.59 5.58 5.58 5.58


БuA = 2.58 Tn/m2 a 1.42 1.32 1.31 1.31 1.31 5.23 Tn/m2 1.52 Tn/m2

Amplicamos momento en punto A As = 5.58 cm2


MUA = 5.66
1 A
Comparacion con acero minimo
As minimos verticales 0.25 m
A  0 . 0018 * b * d
s.minimo Acero estructural 5.578 cm2
As minimo = 4.950 cm2 0.02 Tn/m2
0.86 Tn/m2
Analisis Diseño de Talon
БuB = 1.47 Tn/m2
Бu2 = 0.03 Tn/m2
Amplicamos momento en punto B
MUB = 0.31
AS 0.33 0.33 0.33 0.33 0.33
a 0.08 0.08 0.08 0.08 0.08

Comparacion con acero minimo As = 0.33 cm2


As minimos verticales

A  0 . 0018 * b * d
s.minimo Acero estructural 4.950 cm2
As minimo = 4.950 cm2
Calculo de acero transversal
A  0 . 0018 * b * d As minimo = 4.950 cm2 Acero transversal 4.950 cm2
s.minimo
El espaciamiento de acero esta en funcion a un multiplo de 2,5 inferior solo toma valores siguientes: 2,5 5, 7,5, 10, 12,5, 15, 17,5, 20 etc

Refuerzo acero longitudinal Refuerzo acero Transversal

N° Φ de acero AREA ACERO (Cm2) Peso (kg/ml) Punta Talon Punta Talon
3 3/8" 0.71 0.560 12.5 cm 12.5 cm 12.5 cm 12.5 cm
4 1/2" 1.29 0.994 22.5 cm 25.0 cm 25.0 cm 25.0 cm
5 5/8" 1.99 1.552 35.0 cm 40.0 cm 40.0 cm 40.0 cm
6 3/4" 2.84 2.235 50.0 cm 55.0 cm 55.0 cm 55.0 cm
8 1" 5.1 3.973 90.0 cm 102.5 cm 102.5 cm 102.5 cm
11 1 3/8" 10.06 7.907 180.0 cm 202.5 cm 202.5 cm 202.5 cm

IV .- DE REFUERZO POR CONTRACCIÓN Y POR TEMPERATURA PARA LOSA

As minimos para losa


Refuerzo acero
N° Φ de acero AREA ACERO (Cm2) Peso (kg/ml) Long. Transv.
3 3/8" 0.71 0.560 25.0 cm 25.0 cm
4 1/2" 1.29 0.994 47.5 cm 47.5 cm
As minimo = 2.700 cm2
5 5/8" 1.99 1.552 72.5 cm 72.5 cm
6 3/4" 2.84 2.235 105.0 cm 105.0 cm
8 1" 5.1 3.973 187.5 cm 187.5 cm
11 1 3/8" 10.06 7.907 372.5 cm 372.5 cm