Documentos de Académico
Documentos de Profesional
Documentos de Cultura
PROY FINAL Memoria Calculo Diseño Electrico
PROY FINAL Memoria Calculo Diseño Electrico
DISTANCIA = 4.35m + 0.90m + 2.20m = 7.45m DISTANCIA = 2.35m + 0.90m + 1.30m = 4.55m
1500𝑉𝐴 1500𝑉𝐴
𝐼= = 12.5 𝐴 𝐼= = 12.5 𝐴
120𝑉 120𝑉
PROTECCION: PROTECCION:
CONDUCTOR: CONDUCTOR:
(TABLA 310-16) = 30amp →#12 THHN-90°C Cu (TABLA 310-16) = 30amp →#12 THHN-90°C Cu
(TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410 (TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410
CT = 0.6011V CT = 0.3671V
0.6011𝑉 0.4397𝑉
%𝐶𝑇 = ∙ 100 %𝐶𝑇 = ∙ 100
120𝑉 120𝑉
% CT = 0.5009 % CT = 0.3059
Ø DE CANALIZACION: Ø DE CANALIZACION:
(TABLA 1, CAP9 NEC) CAL #12THHN = 12.70mm = 13mm PVC (TABLA 1, CAP9 NEC) CAL #12THHN = 12.70mm = 13mm PVC
CIRCUITO #5: TOMACORRIENTES 2 COCINA. CIRCUITO #6: SALIDA MICROONDAS.
DISTANCIA = 3.25m + 0.90m + 1.30m = 5.45m DISTANCIA = 3.00m + 0.90m + 1.30m = 5.20m
1500𝑉𝐴 1200𝑉𝐴
𝐼= = 12.5 𝐴 𝐼= = 10.0 𝐴
120𝑉 120𝑉
PROTECCION: PROTECCION:
CONDUCTOR: CONDUCTOR:
(TABLA 3-6) = 20amp →#12-75°C (TABLA 3-6) = 15amp →#14-75°C se aumenta a →#12-75°C
(TABLA 310-16) = 30amp →#12 THHN-90°C Cu (TABLA 310-16) = 30amp →#12 THHN-90°C Cu
(TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410 (TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410
CT = 0.4397V CT = 0.3356V
0.4397𝑉 0.3356𝑉
%𝐶𝑇 = ∙ 100 %𝐶𝑇 = ∙ 100
120𝑉 120𝑉
% CT = 0.3664 % CT = 0.2796
Ø DE CANALIZACION: Ø DE CANALIZACION:
(TABLA 1, CAP9 NEC) CAL #12THHN = 12.70mm = 13mm PVC (TABLA 1, CAP9 NEC) CAL #12 THHN = 12.70mm = 13mm PVC
CIRCUITO #7: SALIDA REFRIGERADOR. CIRCUITO #8 - 9: SALIDA COCINA.
DISTANCIA = 2.00m + 0.90m + 1.30m = 4.20m DISTANCIA = 3.40m + 0.90m + 1.30m = 5.60m
1200𝑉𝐴 8000𝑉𝐴
𝐼= = 10.0 𝐴 𝐼= = 33.33 𝐴
120𝑉 240𝑉
PROTECCION: PROTECCION:
CONDUCTOR: CONDUCTOR:
(TABLA 3-6) = 15amp →#14-75°C se aumenta a →#12-75°C (TABLA 3-6) = 50amp →#6-75°C
(TABLA 310-16) = 30amp →#12 THHN-90°C Cu (TABLA 310-16) = 75amp →#6 THHN-90°C Cu
(TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410 (TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.0849
CT = 0.2711V CT = 0.6004V
0.2711𝑉 0.6004𝑉
%𝐶𝑇 = ∙ 100 %𝐶𝑇 = ∙ 100
120𝑉 240𝑉
% CT = 0.2259 % CT = 0.2501
Ø DE CANALIZACION: Ø DE CANALIZACION:
(TABLA 1, CAP9 NEC) CAL #12 THHN = 12.70mm = 13mm PVC (TABLA 1, CAP9 NEC) CAL #8 THHN = 19.05mm = 19mm PVC
CIRCUITO #10: TOMACORRIENTES BAÑOS. CIRCUITO #11: TOMACORRIENTES LAVANDERIA.
DISTANCIA = 1.80m + 0.90m + 1.20m = 3.90m DISTANCIA = 3.40m + 0.90m + 1.30m = 5.60m
1200𝑉𝐴 1200𝑉𝐴
𝐼= = 10.0 𝐴 𝐼= = 10.0 𝐴
120𝑉 120𝑉
PROTECCION: PROTECCION:
CONDUCTOR: CONDUCTOR:
(TABLA 3-6) = 15amp →#14-75°C se aumenta a →#12-75°C (TABLA 3-6) = 15amp →#14-75°C se aumenta a →#12-75°C
(TABLA 310-16) = 30amp →#12 THHN-90°C Cu (TABLA 310-16) = 30amp →#12 THHN-90°C Cu
(TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410 (TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410
CT = 0.2517V CT = 0.3614V
0.2517𝑉 0.3614𝑉
%𝐶𝑇 = ∙ 100 %𝐶𝑇 = ∙ 100
120𝑉 120𝑉
% CT = 0.2097 % CT = 0.3011
Ø DE CANALIZACION: Ø DE CANALIZACION:
(TABLA 1, CAP9 NEC) CAL #12 THHN = 12.70mm = 13mm PVC (TABLA 1, CAP9 NEC) CAL #12 THHN = 12.70mm = 13mm PVC
CIRCUITO #12 - 13: SALIDA CENTRO DE LAVADO. CIRCUITO #14 - 15: SALIDA CALENTADOR DE AGUA.
DISTANCIA = 3.60m + 0.90m + 1.30m = 5.80m DISTANCIA = 4.80m + 0.90m + 1.30m = 7.00m
6000𝑉𝐴 10000𝑉𝐴
𝐼= = 25.0 𝐴 𝐼= = 41.66 𝐴
240𝑉 240𝑉
PROTECCION: PROTECCION:
CONDUCTOR: CONDUCTOR:
(TABLA 310-16) = 55amp →#8 THHN-90°C Cu (TABLA 310-16) = 75amp →#6 THHN-90°C Cu
(TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.1350 (TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.0849
CT = 0.7417V CT = 0.9381V
0.7417𝑉 0.9381𝑉
%𝐶𝑇 = ∙ 100 %𝐶𝑇 = ∙ 100
240𝑉 240𝑉
% CT = 0.3090 % CT = 0.3908
Ø DE CANALIZACION: Ø DE CANALIZACION:
(TABLA 1, CAP9 NEC) CAL #8 THHN = 19.05mm = 19mm PVC (TABLA 1, CAP9 NEC) CAL #6 THHN = 25.40mm = 25mm PVC
CIRCUITO #16: TOMACORRIENTES DORMITORIO PRINCIPAL. CIRCUITO #17: TOMACORRIENTES DORMITORIO SECUNDARIO.
DISTANCIA = 5.10m + 1.00m + 0.30m = 6.40m DISTANCIA = 5.00m + 1.00m + 0.30m = 6.30m
1500𝑉𝐴 1500𝑉𝐴
𝐼= = 12.5 𝐴 𝐼= = 12.5 𝐴
120𝑉 120𝑉
PROTECCION: PROTECCION:
CONDUCTOR: CONDUCTOR:
(TABLA 310-16) = 30amp →#12 THHN-90°C Cu (TABLA 310-16) = 30amp →#12 THHN-90°C Cu
(TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410 (TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410
CT = 0.5164V CT = 0.5083V
0.5164𝑉 0.5083𝑉
%𝐶𝑇 = ∙ 100 %𝐶𝑇 = ∙ 100
120𝑉 120𝑉
% CT = 0.4303 % CT = 0.4235
Ø DE CANALIZACION: Ø DE CANALIZACION:
(TABLA 1, CAP9 NEC) CAL #12THHN = 12.70mm = 13mm PVC (TABLA 1, CAP9 NEC) CAL #12THHN = 12.70mm = 13mm PVC
CIRCUITO #18: TOMACORRIENTES GENERAL SEGUNDO NIVEL. CIRCUITO #19: LUMINARIAS GENERAL PRIMER NIVEL.
1500𝑉𝐴 360𝑉𝐴
𝐼= = 12.5 𝐴 𝐼= =3𝐴
120𝑉 120𝑉
PROTECCION: PROTECCION:
CONDUCTOR: CONDUCTOR:
(TABLA 3-6) = 20amp →#12-75°C (TABLA 3-6) = 15amp →#14-75°C se aumenta a →#12-75°C
(TABLA 310-16) = 30amp →#12 THHN-90°C Cu (TABLA 310-16) = 30amp →#12 THHN-90°C Cu
(TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410 (TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410
CT = 0.3832V CT = 0.0910V
0.3832𝑉 0.0910𝑉
%𝐶𝑇 = ∙ 100 %𝐶𝑇 = ∙ 100
120𝑉 120𝑉
% CT = 0.3193 % CT = 0.0758
Ø DE CANALIZACION: Ø DE CANALIZACION:
(TABLA 1, CAP9 NEC) CAL #12THHN = 12.70mm = 13mm PVC (TABLA 1, CAP9 NEC) CAL #12THHN = 12.70mm = 13mm PVC
CIRCUITO #20: LUMINARIAS SALA – COCINA - LAVANDERIA. CIRCUITO #21: LUMINARIAS GENERAL SEGUNDO NIVEL.
480𝑉𝐴 300𝑉𝐴
𝐼= =4𝐴 𝐼= = 2.5 𝐴
120𝑉 120𝑉
PROTECCION: PROTECCION:
CONDUCTOR: CONDUCTOR:
(TABLA 3-6) = 15amp →#14-75°C se aumenta a →#12-75°C (TABLA 3-6) = 15amp →#14-75°C se aumenta a →#12-75°C
(TABLA 310-16) = 30amp →#12 THHN-90°C Cu (TABLA 310-16) = 30amp →#12 THHN-90°C Cu
(TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410 (TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410
CT = 0.1471V CT = 0.0468V
0.1471𝑉 0.0468𝑉
%𝐶𝑇 = ∙ 100 %𝐶𝑇 = ∙ 100
120𝑉 120𝑉
% CT = 0.1225 % CT = 0.0390
Ø DE CANALIZACION: Ø DE CANALIZACION:
(TABLA 1, CAP9 NEC) CAL #12THHN = 12.70mm = 13mm PVC (TABLA 1, CAP9 NEC) CAL #12THHN = 12.70mm = 13mm PVC
CIRCUITO #22: LUMINARIAS DORMITORIOS. CALCULO DE PROTECCION PRINCIPAL.
PROTECCION: 21744𝑉𝐴
𝐼= = 90.6 𝐴
240𝑉
(3.5 𝐴) ∙ (1.25) = 4.375 𝐴
CORRIENTE DE DISEÑO, CONSUMO = 90.6 A
DISYUNTOR DE 1/20amp, 120V
PROTECCION:
CONDUCTOR:
(90.6 𝐴) ∙ (1.25) = 113.25 𝐴
(TABLA 3-6) = 15amp →#14-75°C se aumenta a →#12-75°C
DISYUNTOR DE 2/125amp
(TABLA 310-16) = 30amp →#12 THHN-90°C Cu
CONDUCTOR:
FACTOR CABLE (CORRECCION):
(TABLA 310-16) = 170amp →#1/0 THHN-90°C Cu
(TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.3410
FACTOR CABLE (CORRECCION):
FACTOR DEL SISTEMA:
(TABLA 1.3-13) CANALIZADO NO MAGNETICO (PVC) F.P.100 = 0.0211
MONOFASICO, 3 CONDUCTORES, FASE-NEUTRO = 0.577
CAIDA DE TENSION:
CAIDA DE TENSION:
(0.0211) ∙ (90.6 𝐴) ∙ (6.20𝑚) ∙ (0.577)
𝐶𝑇 =
(0.3410) ∙ (3.5 𝐴) ∙ (5.50𝑚) ∙ (0.577) 30.48
𝐶𝑇 =
30.48
CT = 0.2243V
CT = 0.1242V
PORCENTAJE DE CAIDA DE TENSION:
PORCENTAJE DE CAIDA DE TENSION:
0.2243𝑉
%𝐶𝑇 = ∙ 100
0.1242𝑉 240𝑉
%𝐶𝑇 = ∙ 100
120𝑉
% CT = 0.0934
% CT = 0.1035
Ø DE CANALIZACION:
Ø DE CANALIZACION:
(TABLA 1, CAP9 NEC) CAL #1/0THHN = 12.70mm = 38.10mm EMT
(TABLA 1, CAP9 NEC) CAL #12THHN = 12.70mm = 13mm PVC