Documentos de Académico
Documentos de Profesional
Documentos de Cultura
FACULDAD DE INGENIERIA
ESCUELA ACADÉMICO PROFESIONAL DE INGENIERÍA CIVIL
DEPARTAMENTO ACADEMICO DE INGENIERIA DE LOS RECURSOS
HIDROLOGIA SUPERFICIAL
ALUMNO:
• DELGADO RAMOS, Francis Gregory.
DOCENTE:
Msc.Ing. José Antonio Coronel Delgado.
JAÉN – PERÚ
2018
lOMoARcPSD|11510943
CONTENIDO
INTRODUCCION...............................................................................................................1
1. CALCULO DE CAUDAL MAXIMO.......................................................................2
1.1. OBJETIVOS.........................................................................................................2
1.2. ANALISIS ESTADISTICO DE LOS DATOS..............................................2
1.2.1. Modelos de distribución......................................................................2
1.2.2. curvas intensidad – duración – frecuencia.....................................2
1.3. ESTIMACION DE CAUDALES.......................................................................3
1.3.1. El Método Racional...............................................................................3
1.4. TIEMPO DE RETORNO.................................................................................4
2. ACERCA DEL PROGRAMA HIDROESTA 2...................................................5
3. CALCULOS.................................................................................................................7
3.1. DATOS.................................................................................................................7
3.2. ANALSIS ESTADISTICO Y CALCULO DE CAUDAL MAXIMO PARA
UNA PP DE 10 MIN..........................................................................................9
3.2.1. ANALISIS ESTADISTICOS DE LOS DATOS....................................10
3.2.2. CURVA IDF................................................................................................12
3.2.3. CAUDAL MAX DE DISEÑO..................................................................14
3.3. ANALSIS ESTADISTICO Y CALCULO DE CAUDAL MAXIMO PARA
UNA PP DE 30 MIN.........................................................................................15
3.3.1. ANALISIS ESTADISTICOS DE LOS DATOS....................................16
3.3.2. CURVA IDF................................................................................................18
3.3.3. INTENSIDAD MAXIMA.........................................................................20
3.3.4. CAUDAL MAXIMO.................................................................................21
3.4. ANALSIS ESTADISTICO Y CALCULO DE CAUDAL MAXIMO PARA
UNA PP DE 60 MIN.........................................................................................22
3.4.1. ANALISIS ESTADISTICOS DE LOS DATOS....................................23
3.4.2. CURVA IDF................................................................................................25
3.4.3. INTENSIDAD MAXIMA.........................................................................27
3.4.4. CAUDAL MAXIMO.................................................................................28
3.5. ANALSIS ESTADISTICO Y CALCULO DE CAUDAL MAXIMO PARA
UNA PP DE 60 MIN.........................................................................................29
3.5.1. ANALISIS ESTADISTICOS DE LOS DATOS....................................30
3.5.2. CURVAS IDF..........................................................................................32
3.5.3. INTENSIDAD MAXIMA.........................................................................34
3.5.4. CAUDAL MAXIMO.................................................................................35
INTRODUCCION
Agraria de la Molina.
1
lOMoARcPSD|11510943
i. Distribución Normal
ii. Distribución Log Normal 2 parámetros
iii. Distribución Log Normal 3 parámetros
iv. Distribución Gamma 2 parámetros
v. Distribución Gamma 3 parámetros
vi. Distribución Log Pearson tipo III
vii. Distribución Gumbel
viii. Distribución Log Gumbel
Procedimiento:
2
lOMoARcPSD|11510943
Donde:
Q Caudal máximo [m3/s]
:
3
lOMoARcPSD|11510943
4
lOMoARcPSD|11510943
5
lOMoARcPSD|11510943
Además, HidroEsta incluye una ayuda, para que el usuario pueda consultar las
ecuaciones que se utilizan en los cálculos.
Usted amigo seguidor del blog, ya sea ingeniero agrícola, civil, agrónomo,
hidrólogo o especialista que trabaja en el campo de los estudios hidrológicos,
tiene en HidroEsta, una herramienta que le permite realizar cálculos y
simulaciones rápidas en sus trabajos en esta área. Estamos plenamente
seguros que el uso de este software en su trabajo diario le será de gran
provecho.
6
lOMoARcPSD|11510943
3. CALCULOS
3.1. DATOS
INTENSIDAD MAXIMA
Periodo de Duración (min)
Año
10' 30' 60' 120' 240'
1988 102 81 64 42 18
1989 83 70 50 33 16
1990 76 61 42 29 14
1991 102 72 41 32 11
1992 61 58 36 28 14
1993 102 70 50 33 16
1994 100 80 60 0 20
1995 55 42 32 28 16
1996 88 75 55 34 22
1997 101 79 49 35 18
1998 102 72 41 32 11
1999 61 58 36 28 14
2000 102 70 50 33 16
2001 95 87 53 40 15
2002 68 55 41 32 19
2003 55 42 32 28 16
2004 88 75 55 34 22
2005 101 79 49 35 18
2006 102 72 41 32 11
2007 99 83 63 43 13
2008 60 57 35 27 13
2009 87 74 54 33 21
2010 94 86 52 39 14
2011 67 54 40 31 18
2012 98 82 62 42 12
2013 101 79 49 35 18
2014 102 72 41 32 11
2015 61 58 36 28 14
2016 102 70 50 33 16
2017 95 87 53 40 15
2018 91 79 53 47 17
*Estos datos han sido escogidos al azar para fines de aprendizaje del Curso Hidrología Superficial
Universidad Nacional de Cajamarca Sede Jaén
7
lOMoARcPSD|11510943
INTENSIDAD MAXIMA
Tiempo de
Frecuencia retorno Periodo de Duración (min)
Nro. De m
Orden p= T=
10' 30' 60' 120' 240'
n
8
lOMoARcPSD|11510943
9
lOMoARcPSD|11510943
Resultados
Serie de datos X:
N° X
1 102.0
2 102.0
3 102.0
4 102.0
5 102.0
6 102.0
7 102.0
8 102.0
9 101.0
10 101.0
11 101.0
12 100.0
13 99.0
14 98.0
15 95.0
16 95.0
17 94.0
18 91.0
19 88.0
20 88.0
21 87.0
22 83.0
23 76.0
24 68.0
25 67.0
26 61.0
27 61.0
28 61.0
29 60.0
30 55.0
31 55.0
10
lOMoARcPSD|11510943
Como el delta teórico 0.1878, es menor que el delta tabular 0.2443. Los datos se ajustan a
la distribución Normal, con un nivel de significación del 5%
11
lOMoARcPSD|11510943
12
lOMoARcPSD|11510943
CURVAS IDF
40.00
35.00
30.00
Intensidades (mm/h)
25.00
20.00
15.00
10.00
5.00
0.00
0.0 10.0 20.0 30.0 40.0 50.0 60.0
Tiempo
(Horas)
TR 2 TR 5 TR 10 TR 20 TR 25 TR 50 TR 100 TR 200 TR 500
13
lOMoARcPSD|11510943
Resultados
C ponderado: 0.34
Área total: 55 has
Coeficiente C: 0.34
Área de la cuenca: 55 has
I máx.: 27.7772 mm/hr
Q máx.: 1.443 m3/s
14
lOMoARcPSD|11510943
15
lOMoARcPSD|11510943
Serie de datos X:
N° X
1 87.0
2 87.0
3 86.0
4 83.0
5 82.0
6 81.0
7 80.0
8 79.0
9 79.0
10 79.0
11 79.0
12 75.0
13 75.0
14 74.0
15 72.0
16 72.0
17 72.0
18 72.0
19 70.0
20 70.0
21 70.0
22 70.0
23 61.0
24 58.0
25 58.0
26 58.0
27 57.0
28 55.0
29 54.0
30 42.0
31 42.0
16
lOMoARcPSD|11510943
Como el delta teórico 0.1780, es menor que el delta tabular 0.2443. Los datos se ajustan a la distribución
Normal, con un nivel de significación del 5%
Caudal de diseño:
17
lOMoARcPSD|11510943
Intensidades (mm/hora)
10. 12. 14. 16. 18. 20. 22. 24. 48.
1.0 2.0 3.0 4.0 5.0 6.0 8.0 0
Tr Pmax(m 0 0 0 0 0 0 0 0
m) 0.6 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.3
0.25 0.31 0.38 0.44 0.50 0.56 4 3 9 3 7 0 3 7 0 2
5.6 5.1 4.6 4.1 3.8 3.5 3.2 3.1 2.9 1.9
2 70.29 17.57 10.89 8.90 7.73 7.03 6.56 2 3 3 7 2 1 7 0 3 3
6.4 5.8 5.3 4.7 4.3 4.0 3.7 3.5 3.3 2.2
5 80.60 20.15 12.49 10.21 8.87 8.06 7.52 5 8 1 8 8 3 5 5 6 2
6.8 6.2 5.6 5.1 4.6 4.3 4.0 3.7 3.5 2.3
10 85.99 21.50 13.33 10.89 9.46 8.60 8.03 8 8 6 0 8 0 0 9 8 6
7.2 6.6 5.9 5.3 4.9 4.5 4.2 3.9 3.7 2.4
20 90.45 22.61 14.02 11.46 9.95 9.05 8.44 4 0 5 6 2 2 1 9 7 9
7.3 6.7 6.0 5.4 4.9 4.5 4.2 4.0 3.8 2.5
25 91.74 22.94 14.22 11.62 10.09 9.17 8.56 4 0 4 4 9 9 7 4 2 2
7.6 6.9 6.2 5.6 5.1 4.7 4.4 4.2 3.9 2.6
50 95.46 23.87 14.80 12.09 10.50 9.55 8.91 4 7 8 6 9 7 4 1 8 3
7.8 7.2 6.4 5.8 5.3 4.9 4.5 4.3 4.1 2.7
100 98.60 24.65 15.28 12.49 10.85 9.86 9.20 9 0 9 5 6 3 8 5 1 1
8.1 7.4 6.7 6.0 5.5 5.0 4.7 4.4 4.2 2.8
200 101.85 25.46 15.79 12.90 11.20 10.19 9.51 5 4 1 4 4 9 4 9 4 0
500 105.55 26.39 16.36 13.37 11.61 10.56 9.85 8.4 7.7 6.9 6.2 5.7 5.2 4.9 4.6 4.4 2.9
18
lOMoARcPSD|11510943
4 1 5 6 4 8 1 5 0 0
20
lOMoARcPSD|11510943
CURVAS IDF
7.00
6.00
5.00
Intensidades (mm/h)
4.00
3.00
2.00
1.00
0.00
0.0 10.0 20.0 30.0 40.0 50.0 60.0
Tiempo
(Horas)
TR 2 TR 5 TR 10 TR 20 TR 25 TR 50 TR 100 TR 200 TR 500
21
lOMoARcPSD|11510943
Resultados
Par X Y
1 1.0 24.65
2 2.0 15.283
3 3.0 12.48933333
4 4.0 10.846
5 5.0 9.86
6 6.0 9.20266667
7 8.0 7.888
8 10.0 7.1978
9 12.0 6.49116667
10 14.0 5.84557143
11 16.0 5.361375
12 18.0 4.93
13 20.0 4.5849
14 22.0 4.34736364
15 24.0 4.10833333
16 48.0 2.7115
Ecuación Potencial:
Para X = 1.2
El valor de Y es: Y = 21.5996
22
Resultados
C ponderado: 0.3
Area total: 42 has
Coeficiente C: 0.3
Área de la cuenca: 42 has
I máx: 21.5996 mm/hr
Q máx: 0.756 m3/s
23
24
Serie de datos X:
N° X
1 64.0
2 63.0
3 62.0
4 60.0
5 55.0
6 55.0
7 54.0
8 53.0
9 53.0
10 53.0
11 52.0
12 50.0
13 50.0
14 50.0
15 50.0
16 49.0
17 49.0
18 49.0
19 42.0
20 41.0
21 41.0
22 41.0
23 41.0
24 41.0
25 40.0
26 36.0
27 36.0
28 36.0
29 35.0
30 32.0
31 32.0
25
Como el delta teórico 0.1381, es menor que el delta tabular 0.2443. Los datos se ajustan a la distribución
Normal, con un nivel de significación del 5%
Caudal de diseño:
26
Intensidades (mm/hora)
10. 12. 14. 16. 18. 20. 22. 24. 48.
1.0 2.0 3.0 4.0 5.0 6.0 8.0 0
Tr Pmax(mm) 0 0 0 0 0 0 0 0
0.6 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.3
0.25 0.31 0.38 0.44 0.50 0.56 4 3 9 3 7 0 3 7 0 2
3.7 3.4 3.1 2.8 2.5 2.3 2.2 2.0 1.9 1.3
2 47.26 11.82 7.33 5.99 5.20 4.73 4.41 8 5 1 0 7 6 0 8 7 0
4.4 4.0 3.6 3.2 2.9 2.7 2.5 2.4 2.2 1.5
5 54.95 13.74 8.52 6.96 6.04 5.50 5.13 0 1 2 6 9 5 6 2 9 1
4.7 4.3 3.8 3.5 3.2 2.9 2.7 2.6 2.4 1.6
10 58.97 14.74 9.14 7.47 6.49 5.90 5.50 2 0 8 0 1 5 4 0 6 2
4.9 4.5 4.1 3.6 3.3 3.1 2.9 2.7 2.6 1.7
20 62.29 15.57 9.65 7.89 6.85 6.23 5.81 8 5 0 9 9 1 0 5 0 1
5.0 4.6 4.1 3.7 3.4 3.1 2.9 2.7 2.6 1.7
25 63.26 15.82 9.81 8.01 6.96 6.33 5.90 6 2 6 5 4 6 4 9 4 4
5.2 4.8 4.3 3.9 3.5 3.3 3.0 2.9 2.7 1.8
50 66.03 16.51 10.23 8.36 7.26 6.60 6.16 8 2 5 1 9 0 7 1 5 2
5.4 5.0 4.5 4.0 3.7 3.4 3.1 3.0 2.8 1.8
100 68.52 17.13 10.62 8.68 7.54 6.85 6.40 8 0 1 6 3 3 9 2 6 8
5.6 5.1 4.6 4.2 3.8 3.5 3.2 3.1 2.9 1.9
200 70.80 17.70 10.97 8.97 7.79 7.08 6.61 6 7 6 0 5 4 9 2 5 5
5.8 5.3 4.8 4.3 4.0 3.6 3.4 3.2 3.0 2.0
500 73.57 18.39 11.40 9.32 8.09 7.36 6.87 9 7 4 6 0 8 2 4 7 2
27
28
CURVAS IDF
7.00
6.00
5.00
Intensidades (mm/h)
4.00
3.00
2.00
1.00
0.00
0.0 10.0 20.0 30.0 40.0 50.0 60.0
Tiempo
(Horas)
TR 2 TR 5 TR 10 TR 20 TR 25 TR 50 TR 100 TR 200 TR 500
29
Resultados
Par X Y
1 1.0 17.13
2 2.0 10.6206
3 3.0 8.6792
4 4.0 7.5372
5 5.0 6.852
6 6.0 6.3952
7 8.0 5.4816
8 10.0 5.00196
9 12.0 4.5109
10 14.0 4.06225714
11 16.0 3.725775
12 18.0 3.426
13 20.0 3.18618
14 22.0 3.02110909
15 24.0 2.855
16 48.0 1.8843
Ecuación Potencial:
Para X = 1.2
El valor de Y es: Y = 15.0102
30
Resultados
C ponderado: 0.39
Area total: 52 has
Coeficiente C: 0.39
Área de la cuenca: 52 has
I máx: 15.0102 mm/hr
Q máx: 0.846 m3/s
31
32
Serie de datos X:
N° X
1 47.0
2 43.0
3 42.0
4 42.0
5 40.0
6 40.0
7 39.0
8 35.0
9 35.0
10 35.0
11 34.0
12 34.0
13 33.0
14 33.0
15 33.0
16 33.0
17 33.0
18 32.0
19 32.0
20 32.0
21 32.0
22 32.0
23 31.0
24 29.0
25 28.0
26 28.0
27 28.0
28 28.0
29 28.0
30 27.0
31 0.0
33
Como el delta teórico 0.1768, es menor que el delta tabular 0.2443. Los datos se ajustan a la distribución
Normal, con un nivel de significación del 5%
Caudal de diseño:
34
Intensidades (mm/hora)
10. 12. 14. 16. 18. 20. 22. 24. 48.
1.0 2.0 3.0 4.0 5.0 6.0 8.0
Tr Pmax(mm) 0 0 0 0 0 0 0 0 0
0.6 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.3
0.25 0.31 0.38 0.44 0.50 0.56 4 3 9 3 7 0 3 7 0 2
2.6 2.4 2.1 1.9 1.7 1.6 1.5 1.4 1.3 0.9
2 32.84 8.21 5.09 4.16 3.61 3.28 3.07 3 0 6 5 9 4 3 5 7 0
3.1 2.8 2.6 2.3 2.1 1.9 1.8 1.7 1.6 1.0
5 39.50 9.88 6.12 5.00 4.35 3.95 3.69 6 8 0 4 5 8 4 4 5 9
3.4 3.1 2.8 2.5 2.3 2.1 2.0 1.9 1.7 1.1
10 42.99 10.75 6.66 5.45 4.73 4.30 4.01 4 4 3 5 4 5 0 0 9 8
3.6 3.3 3.0 2.7 2.4 2.2 2.1 2.0 1.9 1.2
20 45.86 11.47 7.11 5.81 5.04 4.59 4.28 7 5 2 2 9 9 3 2 1 6
3.7 3.4 3.0 2.7 2.5 2.3 2.1 2.0 1.9 1.2
25 46.70 11.68 7.24 5.92 5.14 4.67 4.36 4 1 7 7 4 4 7 6 5 8
3.9 3.5 3.2 2.9 2.6 2.4 2.2 2.1 2.0 1.3
50 49.10 12.28 7.61 6.22 5.40 4.91 4.58 3 8 3 1 7 6 8 6 5 5
4.1 3.7 3.3 3.0 2.7 2.5 2.3 2.2 2.1 1.4
100 51.26 12.82 7.95 6.49 5.64 5.13 4.78 0 4 7 4 9 6 8 6 4 1
4.2 3.8 3.5 3.1 2.8 2.6 2.4 2.3 2.2 1.4
200 53.23 13.31 8.25 6.74 5.86 5.32 4.97 6 9 0 6 9 6 8 5 2 6
4.4 4.0 3.6 3.3 3.0 2.7 2.5 2.4 2.3 1.5
500 55.63 13.91 8.62 7.05 6.12 5.56 5.19 5 6 6 0 2 8 9 5 2 3
35
36
CURVAS IDF
7.00
6.00
5.00
Intensidades (mm/h)
4.00
3.00
2.00
1.00
0.00
0.0
Tiempo
(Horas)
TR 2 TR 5 TR 10 TR 20 TR 25 TR 50 TR 100 TR 200 TR 500
37
Resultados
Par X Y
1 1.0 12.815
2 2.0 7.9453
3 3.0 6.49293333
4 4.0 5.6386
5 5.0 5.126
6 6.0 4.78426667
7 8.0 4.1008
8 10.0 3.74198
9 12.0 3.37461667
10 14.0 3.03898571
11 16.0 2.7872625
12 18.0 2.563
13 20.0 2.38359
14 22.0 2.2601
15 24.0 2.13583333
16 48.0 1.40965
Ecuación Potencial:
Para X = 1.2
El valor de Y es: Y = 11.2292
38
Resultados
C ponderado: 0.38
Area total: 73 has
Coeficiente C: 0.38
Área de la cuenca: 73 has
I máx: 11.2292 mm/hr
Q máx: 0.865 m3/s
39
40
Serie de datos X:
N° X
1 22.0
2 22.0
3 21.0
4 20.0
5 19.0
6 18.0
7 18.0
8 18.0
9 18.0
10 18.0
11 17.0
12 16.0
13 16.0
14 16.0
15 16.0
16 16.0
17 15.0
18 15.0
19 14.0
20 14.0
21 14.0
22 14.0
23 14.0
24 13.0
25 13.0
26 12.0
27 11.0
28 11.0
29 11.0
30 11.0
31 16.0
41
Como el delta teórico 0.0964, es menor que el delta tabular 0.2443. Los datos se ajustan a la distribución
Normal, con un nivel de significación del 5%
Caudal de diseño:
42
Intensidades (mm/hora)
10. 12. 14. 16. 18. 20. 22. 24. 48.
1.0 2.0 3.0 4.0 5.0 6.0 8.0 0
Tr Pmax(mm) 0 0 0 0 0 0 0 0
0.6 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.3
0.25 0.31 0.38 0.44 0.50 0.56 4 3 9 3 7 0 3 7 0 2
1.2 1.1 1.0 0.9 0.8 0.7 0.7 0.7 0.6 0.4
2 15.77 3.94 2.44 2.00 1.73 1.58 1.47 6 5 4 3 6 9 3 0 6 3
1.4 1.3 1.2 1.0 1.0 0.9 0.8 0.8 0.7 0.5
5 18.42 4.61 2.86 2.33 2.03 1.84 1.72 7 4 1 9 0 2 6 1 7 1
1.5 1.4 1.3 1.1 1.0 0.9 0.9 0.8 0.8 0.5
10 19.81 4.95 3.07 2.51 2.18 1.98 1.85 8 5 0 7 8 9 2 7 3 4
1.6 1.5 1.3 1.2 1.1 1.0 0.9 0.9 0.8 0.5
20 20.95 5.24 3.25 2.65 2.30 2.10 1.96 8 3 8 4 4 5 7 2 7 8
1.7 1.5 1.4 1.2 1.1 1.0 0.9 0.9 0.8 0.5
25 21.29 5.32 3.30 2.70 2.34 2.13 1.99 0 5 0 6 6 6 9 4 9 9
1.7 1.6 1.4 1.3 1.2 1.1 1.0 0.9 0.9 0.6
50 22.24 5.56 3.45 2.82 2.45 2.22 2.08 8 2 6 2 1 1 3 8 3 1
1.8 1.6 1.5 1.3 1.2 1.1 1.0 1.0 0.9 0.6
100 23.10 5.78 3.58 2.93 2.54 2.31 2.16 5 9 2 7 6 6 7 2 6 4
1.9 1.7 1.5 1.4 1.3 1.1 1.1 1.0 1.0 0.6
200 23.89 5.97 3.70 3.03 2.63 2.39 2.23 1 4 7 2 0 9 1 5 0 6
1.9 1.8 1.6 1.4 1.3 1.2 1.1 1.1 1.0 0.6
500 24.84 6.21 3.85 3.15 2.73 2.48 2.32 9 1 4 7 5 4 6 0 4 8
43
44
CURVAS IDF
7.00
6.00
5.00
Intensidades (mm/h)
4.00
3.00
2.00
1.00
0.00
0.0
Tiempo
(Horas)
TR 2 TR 5 TR 10 TR 20 TR 25 TR 50 TR 100 TR 200 TR 500
45
Resultados
Par X Y
1 1.0 5.775
2 2.0 3.5805
3 3.0 2.926
4 4.0 2.541
5 5.0 2.31
6 6.0 2.156
7 8.0 1.848
8 10.0 1.6863
9 12.0 1.52075
10 14.0 1.3695
11 16.0 1.2560625
12 18.0 1.155
13 20.0 1.07415
14 22.0 1.0185
15 24.0 0.9625
16 48.0 0.63525
Ecuación Potencial:
Para X = 1.2
El valor de Y es: Y = 5.0604
46
Resultados
C ponderado: 0.55
Area total: 107 has
47
4. CONCLUSIONES
• Nuestros Datos se Ajustaron a la Distribución Normal.
• Se determinó las precipitaciones máximas para cada precipitación de
manera objetiva con el programa HIDROESTA 2.
• La precipitación máxima para 10’, 30’, 60’, 120’, 240’ es de 27.7772,
21.5996, 15.0102, 11.9222, 5.0604 mm/hr respectivamente.
• Se determinó un caudal máximo para la cuenda de 1.443 m3/s.
5. RECOMENDACIONES
❖ Se debe insertar los datos cuidadosamente al programa HIDROESTA
2 teniendo en cuenta que estos seas correctos.
❖ Para un mejor aprovechamiento del Software se tomar un curso
básico del mismo.
48