Está en la página 1de 4

CALCULO DE LA CAPACIDAD DE LIMPIEZA

DATOS MODELO DE BINGHAM


Densidad = 10.2 lbs/gal
Lect 600 = 65 Visc Plast = Lect 600 - Lect 300
Lect 300 = 46 Pto Cedent =Lect 300 - Visc Plast
Long cut(pulg) = 2.7 Estas celdas se llenan cuando el Cut
Espes Cut (pulg) = 0.45 no es esferico Visc Plast = 19 cps
Area = 1.215 pulgs2
Diam Cut = 1.24 pulgs Llenar cuando el Cut es Esferico Pto Cedent = 27 lbs/100 pie2
Densidad Cut= 21.258 lbs/gal
Caudal = 540 gpm
D Hoyo = 8.5 pulgs
DExt Dc´s = 6.25 pulgs VELOCIDAD ANULAR
DInt Dc´s = 2.875 pulgs Vel Anular = 24,5 * Q pies/min
DExt Dp´s = 5 pulgs (DM2 - Dm2)
DInt Dp´s = 4.276 pulgs 2.69 T.J
DInt Rev = 8.755 pulgs Vel An H-Dc´s = 399 pies/min
P.t = 8000
Long BHA = 859 pies Vel An H-Dp´s = 280 pies/min
Long Dp´s = 7141 pies
Prof Rev Ant = 3030 pies Vel An H-Dp´s = 4.67 pies/seg

Vel An Rev-Dp´s = 256 pies/min

VELOCIDAD CRITICA
Vel Critica = 1,078 * Vp + 1,078 SQRT((Vp2) + 9,256 * (Dh - DDC´S)2 * Yp * Dens)
Dens * (Dh - DDC´S)

Vel Critica = 378 gal/seg

VELOCIDAD DE DESLIZQAMIENTO DE LA PARTICULA


VSLIP/Laminar = 53,3 * (Dens Cut - Dems Lodo) * Diam Cut2 * Vel An(pies/seg)
6,65 * Yp * (DHOYO - DDp´s) + Vp * Vel An

VSLIP/Laminar = 5.93 pies/min

VOLUMEN ANULAR
Vol An = Capacidad * Long del Intervalo

Vol An = 355 Bls

EFICIENCIA DEL TRANSPORTE DE RIPIOS

Cap Limpieza = (Vel An - Vel Slip) x 100 Cap Limp = -27 %


Vel An (pies/seg)

CAIDAS DE PRESION EN EL SISTEMA

VELOCIDAD PROMEDIO EN LA TUBERIA DE PERFORACION

Vel Prom DP´S/DC´S = 0,408 x Caudal pies/seg


(Diam Inter DP´S/DC´S)2

Vel Pr DP´S = 12 pies/seg Vel Pr DC´S = 27 pies/seg

VELOCIDAD PROMEDIO EN EL ESPACIO ANULAR

Vel Prom Anular = 0,408 x Caudal pies/seg


Diam HOYO2 - Diam Ext DP´S/DC´S2

Vel Prom Anular/ DP´S = 5 pies/seg Vel Prom Anular/ DC´S = 7 pies/seg

Velocidad anular < Velocidad crítica =====>> Flujo Laminar


Velocidad anular > Velocidad crítica =====>> Flujo turbulento
CAIDA DE PRESION DENTRO DE LA TUBERIA DE PERFORACION
FLUJO LAMINAR FLUJO TURBULENTO

DP =Visc Plast x Vel Prom DP´S + Pto Cedente x L DP = Dens Lodo0,75 x Vel Prom DP´S/DC´S1,75 x Visc Plast0,25 x L
(1500 x (Diam Inter DP´S/DC´S)2) 225 x Diam Inter DP´S/DC´S (1800 x Diam Inter DP´S/DC´S)1,25

DPDP´S = psi DPDP´S = 56


DPDC´S = 22 psi DPDC´S = 292

CAIDA DE PRESION EN EL ANULAR


FLUJO LAMINAR

DP = Visc Plast x Vel Anul + Pto Cedente x L DP = Dens Lodo0,75 x Vel Anul DP´S/DC´S1,75 x Visc Plast0,25 x L
(1000 x (Diam HOYO - D ExtDP´S/DC´S)2) 200 x (Diam HOYO - D ExtDP´S/DC´S) (1396 x (Diam HOYO - D ExtDP´S/DC´S)1,25

DPHoyo-Dp´s = psi DPDP´S = 116


DPHoy-Dc´s = psi DPDC´S = 45
CULO DE LA CAPACIDAD DE LIMPIEZA
PRESION DENTRO DE LA TUBERIA DE PERFORACION
FLUJO TURBULENTO

Dens Lodo0,75 x Vel Prom DP´S/DC´S1,75 x Visc Plast0,25 x L


(1800 x Diam Inter DP´S/DC´S)1,25

psi
psi

CAIDA DE PRESION EN EL ANULAR

Dens Lodo0,75 x Vel Anul DP´S/DC´S1,75 x Visc Plast0,25 x L


(1396 x (Diam HOYO - D ExtDP´S/DC´S)1,25

psi
psi

También podría gustarte