Está en la página 1de 34

AÑO 2005 2010 2015 2020

HABITANTES 6342 6449 6695 7321

METODO ARITMETICO

K= Pf - Po K1= 125.20
Tt - To K2= 49.20
K3= 21.40
K Promedio= 65.27

Pf= Po + K (Tt - To) Pf= 8626

M.A M.G
TASA DE CRECIMIENTO= 85% 83%

M.A M.G
POBLACION A 2040 1109 1095

DOTACION DE AGUA POTABLE

CALCULO DE Q.M.D

CALCULO POR PERSONAS

Q.M.D = Población x Dotación


86400

Q.M.D = 2.05 L/S

CALCULO PARA ESCUELA

Q.M.D = Escuela x Dotación


86400

Q.M.D = 0.16 L/S

CALCULO PARA ZONA VERDE

Q.M.D = A. Verde x Dotación


86400
Q.M.D = 0.19 L/S

CALCULO PARA ZONA DE EQUIPAMIENTO

Q.M.D = A. Equipo. x Dotación


86400

Q.M.D = 0.05 L/S

CAUDAL TOTAL

Q.M.D TOTAL = 2.45 L/S

CALCULO DE 20 % DE FUGAS Y DESPERDICIO

Q.M.D (20 %) = 2.94 L/S

CAUDAL MAXIMO HORARIO

Q.Max.H = K2 x Q.M.D

Q.Max.H = 7.06 L/S

CAUDAL MINIMO HORARIO

Q.Min.H = K3 x Q.M.D

Q.Min.H = 0.88 L/S

CAUDAL MAXIMO DIARIO

Q.Max.D = K1 x Q.M.D

Q.Max.D = 4.41 L/S

CAUDAL DE BOMBEO

Tiempo máximo de bombeo 20 h diarios Eficiencia de un 80%

Q.Bombeo = 24/n x Q.Max.D

Q.Bombeo = 6.62 L/S


ALMACENAMIENTO

V. consumo: V. incendio + V. reparación V. i=


V. h=
Vc= V.h * Q.M.D * 86.4 Aducción=
Reparación=
Vc= 122.00 m3

Vr= Q. Bombeo * Aducción

Vr= 47.66 m3

121.33 : 90 + 47.39

121.33 47.66 m3

ALTURA DEL TANQUE

h= V.Diseño/(π*D2/4) V.Diseño=

h= 4.00 m Diámetro=

PROPOSICION DE DIAMETRO

Diámetro= 1.3*(X)^1/4*√Q.Dis

Diámetro= 0.10 m

Diámetro= 4.00 pul.


M.A M.G
2040 2040 POBACION DE URBANIZACION 2020 = 600
8626 8869

O METODO GEOMETRICO

i= ((Pob. "n")/(Pob."1"))^(1/n)-1 i1=


i2=
i3=
i Promedio=

Pf= Pob.año 1 * (1 + i)^año n + año 1 Pf=

CAL
UA POTABLE

Q.M.D

PERSONAS

DOTACION POR PERSONA

160 L/P/D
C.E=

ESCUELA C.E=

DOTACION POR ALUMNO


300 Alumnos
40 L/A/D
DATOS
DOTACION POR DOCENTE LONGITUD=
12 Docentes CAUDAL=
160 L/A/D DIAMETRO=
C=

ONA VERDE
TRAMO
DOTACION POR M2
10812.7 M2 1
1.5 L/M2/D

E EQUIPAMIENTO DATOS
LONGITUD=
DOTACION POR M2 CAUDAL=
2798.95 M2 DIAMETRO=
1.5 L/M2/D C=

TRAMO
OTAL
1

GAS Y DESPERDICIO
DATOS
LONGITUD=
CAUDAL=
DIAMETRO=
O HORARIO C=

K2= 2.4
TRAMO
1

O HORARIO

K3= 0.3

MO DIARIO CARG

K1= 1.5

OMBEO
P
Eficiencia de un 80%

n= 16 Pot=
Pot=
MIENTO

0 m3
48%
3.6 por hora
2 horas

TANQUE

121.33 m3

6.5 m

DIAMETRO

X= n/24

X= 0.67

Q.Dis= 0.00662
Hab.

OMETRICO

0.34%
0.75%
1.80%
0.96%

8869

CALCULO DE BOMBA

CALCULO DE CARGA ESTATICA

DATOS
Nivel del Tanque = 141.77 msnm
Nivel del Pozo= 139 msnm
Nivel Dinámico= 40 m
Altura del Tanque 4.00 m
Altura de Presión (FS)= 20.00 m.c.a

Nivel del tanque - Nivel del Pozo +Nivel Dinámico + Altura del Tanque + Altura de
Presión (fs)

66.77 m

PERDIDAS TUBERIA DE POZO

DATOS FACTOR DE RUGOSIDAD


40 m Hierro 100 Hf
6.62 l/s PVC 120 (m)
4.00 Pulgadas Concreto 140 0.54
100

LONGITUD DIAMETRO DIAMETRO


DE A HWC FLUJO l/seg.
(mts) (pulg) (mm)
1 2 40.00 4.00 101.60 100 6.62
PERDIDAS TUBERIA DE POZO A TANQUE

DATOS FACTOR DE RUGOSIDAD


115.52 m Hierro 100 Hf
6.62 l/s PVC 120 (m)
4.00 Pulgadas Concreto 140 1.12
120

LONGITUD DIAMETRO DIAMETRO


DE A HWC FLUJO l/seg.
(mes) (pul) (mm)
1 2 115.52 4.00 101.60 120 6.62

PERDIDAS POR ALTURA DE TANQUE

DATOS FACTOR DE RUGOSIDAD


4.00 m Hierro 100 Hf
6.62 m3/s PVC 120 (m)
4.00 Pulgadas Concreto 140 0.04
120

LONGITUD DIAMETRO DIAMETRO


DE A HWC FLUJO l/seg.
(mts) (pulg) (mm)
1 2 4.00 4.00 101.60 120 6.62

PERDIDAS TOTALES

HfT= 1.70 m

CARGA DINAMICA TOTAL (CDT)

CDT= C.E + HfT + ELEV. PIEZOMETRICA

CDT= 73.47 m

POTENCIA DE LA BOMBA

CDT * Q Eficiencia= 80%


75 * Eficiencia
Se propone una bomba de 10 HP a
utilizar en proyecto de Abastecimiento
de Agua Potable
Se propone una bomba de 10 HP a
utilizar en proyecto de Abastecimiento
8.00 HP de Agua Potable
V (m/seg)

0.82
V (m/seg)
0.82

V (m/seg)
0.82
DISTRIBUCION DE LA RED

CAUDAL UNITARIO

Datos
𝑄 𝑢𝑛𝑖𝑡𝑎𝑟𝑖𝑜=(𝑄 𝑑𝑒 𝑑𝑖𝑠𝑒ñ𝑜)/(# 𝐴𝑐𝑜𝑚𝑒𝑡𝑖𝑑𝑎𝑠)
Q.Max.H = 7.06 L/S
Q de Zona verder = 0.19 L/S
Q de Escuela = 0.16 L/S
Q unitario = 0.044 L/S/vivienda Q de Zona de Equi. = 0.05 L/S
# Acometidas = 150 Lotes
DATO A USAR= 6.66 L/S

CAUDAL DE DISEÑO

Q.Max.h = Q.M.D + Q incendio Datos


Q.M.D = 0.00245 L/S
Q.Max.h = 0.00 m 3
Q incendio = 0 m3

CUADRO DE DISTRIBUCION

CIRCUITO NUDOS # DE CASAS Q UNIDAD


1-3 - 6.66 L/S
2-3 4 0.18 L/S
I 9 - 10 7 0.31 L/S
3-4 11 0.49 L/S
II 5-6 14 0.62 L/S
10 - 11 7 0.31 L/S
III - 0 0.00 L/S
7-8 3 0.13 L/S
IV 11 - 12 8 0.36 L/S
14 - 15 14 0.62 L/S
V - 0 0.00 L/S
15 - 16 7 0.31 L/S
VI - 0 0.00 L/S
16 - 17 11 0.49 L/S
VII - 0 0.00 L/S
13 - 14 5 0.22 L/S
VIII 18 - 19 14 0.62 L/S
19 - 20 15 0.67 L/S
IX - 0 0.00 L/S
20 - 21 15 0.67 L/S
X - 0 0.00 L/S
21 - 22 15 0.67 L/S
XI - 0 0.00 L/S
SUMA 150 6.66 L/S
DISTRIBUCION DE CAUDALES TRAMOS
CIRCUITO NUDOS Q UNIDAD DE A
3a5 1.06 L/S 3 2
5 a 10 0.4 L/S 3 4
I 10 - 9 1.5 L/S 2 9
9a2 3.82 L/S 3 5
2a3 4 L/S 4 6
3a4 2 L/S 5 6
4a6 1.5 L/S 5 10
II
6a5 0.5 L/S 9 10
5a3 1.06 L/S 10 11
5a6 0.5 L/S 6 7
6a7 1.39 L/S 7 8
III 7 a 11 0.9 L/S 7 11
11 a 10 1.15 L/S 8 12
10 a 5 0.4 L/S 11 12
7a8 0.40 L/S 9 14
8 a 12 0.27 L/S 10 15
IV
12 a 11 1.00 L/S 11 16
11 a7 0.90 L/S 12 17
9 a 10 1.50 L/S 13 14
10 a 15 0.44 L/S 14 15
V
15 a 14 0.40 L/S 15 16
14 a 9 2.01 L/S 16 17
10 a 11 1.15 L/S 13 18
11 a 16 1.05 L/S 14 19
VI
VI
16 a 15 0.10 L/S 15 20
15 a 10 0.44 L/S 16 21
11 a 12 1.00 L/S 17 22
12 a 17 0.91 L/S 18 19
VII
17 a 16 0.05 L/S 19 20
16 a 11 1.05 L/S 20 21
14 a 13 1.00 L/S 21 22
13 a 18 0.78 L/S
VIII
18 a 19 0.16 L/S
19 a 14 0.51 L/S
14 a 15 0.40 L/S
15 a 20 0.12 L/S
IX
20 a 19 0.67 L/S
19 a 14 0.51 L/S
15 a 16 0.10 L/S
16 a 21 0.74 L/S
X
21 a 20 0.12 L/S
20 a 15 0.12 L/S
16 a 17 0.05 L/S
17 a 22 0.47 L/S
XI
22 a 21 0.20 L/S
21 a 16 0.74 L/S
DIAMETROS DIAMETROS LONGUITUD
pulg (mm) mts
2.5 63.5 95.53
2 50.8 94.25
2.5 63.5 61.51
2 50.8 45.12
2 50.8 36.33
2 50.8 87.25
2 50.8 55.54
2 50.8 98.37
2 50.8 89.64
2 50.8 24.43
2 50.8 38.57
2 50.8 51.61
2 50.8 48.82
2 50.8 51.51
2 50.8 52.83
2 50.8 55.64
2 50.8 57.44
2 50.8 55.37
2 50.8 64.57
2 50.8 98.74
2 50.8 90.51
2 50.8 69.62
2 50.8 50.71
2 50.8 54.52
2 50.8 53.86
2 50.8 53.44
2 50.8 53.38
2 50.8 102.12
2 50.8 98.52
2 50.8 90.13
2 50.8 89.59
PROYECTO: URBANIZACION TIPO 1
TRAMOS: 1
NUDOS: 2

DIAMETRO DIAMETRO
TRAMO DE A LONGITUD (mts) HWC FLUJO l/seg.
(pulg) (mm)
1 1 3 67.34 4 101.6 140 7.060

Elev.= 141.77 msnm


Altura propuesta 10 m Se condera que desde la e
esta el tanque, se establec
Elev. Final= 151.77 msnm de 10 m mas la atura del p
Datos que nosotros tenemos que llenar
Datos a proponer
Datos resultantes
Hf Elev. Nudos (m.s.n.m) Elev. Piez. (m.s.n.m) Altura de Presion (m)
V (m/seg)
(m) Aguas arriba Aguas abajo Aguas arriba Aguas abajo Aguas arriba Aguas abajo
0.87 0.55 151.77 140.77 156.77 156.22 5.00 15.45

e condera que desde la elevacion inicial del terreno donde


sta el tanque, se establece una altura de la base del tanque
e 10 m mas la atura del propio tanque de 4 m = a 14 m
1 2 3 4 5 6 7
Sentido de
circuito tramo Ѳ (pulg) L (m) Q0(L/s) sf (m/M) Hf(m)
flujo
3a5 2 33.17 -1.06 -1 -0.0072 -0.2387
5 a 10 2 55.54 -0.4 -1 -0.0012 -0.0659
I 10 a 9 2 98.37 -1.5 -1 -0.0137 -1.3456
9a2 2.5 61.51 3.82 1 0.0260 1.5999
2a3 2.5 95.53 4 1 0.0283 2.7056
-0.0503
3a4 2 94.25 2 1 0.0233 2.1951
4a6 2 36.33 1.51 1 0.0138 0.5031
II
6a5 2 87.25 -0.5 -1 -0.0018 -0.1564
5a3 2 45.12 1.06 1 0.0072 0.3247
2.8665
5a6 2 87.25 0.5 1 0.0018 0.1564
6a7 2 24.43 1.39 1 0.0119 0.2902
III 7 a 11 2 51.61 0.9 1 0.0053 0.2744
11 a 10 2 89.64 -1.15 -1 -0.0084 -0.7500
10 a 5 2 55.54 -0.4 -1 -0.0012 -0.0659
-0.0949
7a8 2 38.57 0.4 1 0.0012 0.0457
8 a 12 2 48.82 0.27 1 0.0006 0.0280
IV
12 a 11 2 51.51 -1.00 -1 -0.0065 -0.3328
11 a 7 2 51.61 -0.90 -1 -0.0053 -0.2744
-0.5334
9 a 10 2 98.37 1.50 1 0.0137 1.3456
10 a 15 2 55.64 0.44 1 0.0014 0.0787
V
15 a 14 2 98.74 -0.40 -1 -0.0012 -0.1171
14 a 9 2 52.83 -2.01 -1 -0.0235 -1.2418
0.0653
10 a 11 2 89.64 1.15 1 0.0084 0.7500
11 a 16 2 57.44 1.05 1 0.0071 0.4061
VI
16 a 15 2 90.51 -0.10 -1 -0.0001 -0.0083
15 a 10 2 55.64 -0.44 -1 -0.0014 -0.0787
1.0692
11 a 12 2 51.51 1.00 1 0.0065 0.3328
12 a 17 2 55.37 0.91 1 0.0054 0.3005
VII
17 a 16 2 69.62 -0.05 -1 0.0000 -0.0018
16 a 11 2 57.44 -1.05 -1 -0.0071 -0.4061
0.2253
14 a 19 2 54.52 0.51 1 0.0019 0.1014
19 a 18 2 102.12 0.16 1 0.0002 0.0222
VIII
18 a 13 2 50.71 -0.78 -1 -0.0041 -0.2069
13 a 14 2 64.57 -1.00 -1 -0.0065 -0.4172
-0.5005
14 a 15 2 98.74 0.40 1 0.0012 0.1171
15 a 20 2 53.86 0.12 1 0.0001 0.0069
IX
20 a 19 2 98.52 -0.67 -1 -0.0031 -0.3034
19 a 14 2 54.52 -0.51 -1 -0.0019 -0.1014
-0.2808
15 a 16 2 90.51 0.10 1 0.0001 0.0083
16 a 21 2 53.44 0.74 1 0.0037 0.1978
X
21 a 20 2 90.13 -0.12 -1 -0.0001 -0.0115
20 a 15 2 53.86 -0.12 -1 -0.0001 -0.0069
0.1876
16 a 17 2 69.62 0.05 1 0.0000 0.0018
17 a 22 2 53.38 0.47 1 0.0016 0.0853
XI
22 a 21 2 89.59 -0.20 -1 -0.0003 -0.0295
21 a 16 2 53.44 -0.74 -1 -0.0037 -0.1978
-0.1402
C= 140
8 9 10 11
Hf/Q ∆Q ∆Qfinal Q1 V (m/seg)
0.2252 0.0159 0.7719 -0.2881 -0.52
0.1647 0.0159 -0.0153 -0.4153 -0.20
0.8970 0.0159 0.0337 -1.4663 -0.74
0.4188 0.0159 0.0159 3.8359 1.21
0.6764 0.0159 0.0159 4.0159 1.26
1.7057
1.0976 -0.7559 -0.7559 1.2441 0.99
0.3332 -0.7559 -0.7559 0.7541 0.75
0.3127 -0.7559 -0.7871 -1.2871 -0.25
0.3063 -0.7559 -0.7719 0.2881 0.52
2.0498
0.3127 0.0312 0.7871 1.2871 0.25
0.2088 0.0312 0.0312 1.4212 0.69
0.3049 0.0312 -0.3058 0.5942 0.44
0.6522 0.0312 0.4756 -0.6744 -0.57
0.1647 0.0312 0.0153 -0.3847 -0.20
1.6433
0.1144 0.3370 0.3370 0.7370 0.20
0.1036 0.3370 0.3370 0.6070 0.13
0.3328 0.3370 0.4492 -0.5508 -0.49
0.3049 0.3370 0.3058 -0.5942 -0.44
0.8557
0.8970 -0.0178 -0.0337 1.4663 0.74
0.1789 -0.0178 -0.0178 0.4222 0.22
0.2928 -0.0178 -0.1693 -0.5693 -0.20
0.6178 -0.0178 -0.0178 -2.0278 -0.99
1.9865
0.6522 -0.4444 -0.4756 0.6744 0.57
0.3868 -0.4444 -0.3321 0.7179 0.52
0.0826 -0.4444 -0.2429 -0.3429 -0.05
0.1789 -0.4444 -0.4444 -0.8844 -0.22
1.3005
0.3328 -0.1123 -0.4492 0.5508 0.49
0.3302 -0.1123 -0.1123 0.7977 0.45
0.0352 -0.1123 -0.2323 -0.2823 -0.02
0.3868 -0.1123 0.3321 -0.7179 -0.52
1.0850
0.1987 0.2652 0.1137 0.6237 0.25
0.1390 0.2652 0.2652 0.4252 0.08
0.2652 0.2652 0.2652 -0.5148 -0.38
0.4172 0.2652 0.2652 -0.7348 -0.49
1.0201
0.2928 0.1515 0.1693 0.5693 0.20
0.0574 0.1515 0.3530 0.4730 0.06
0.4529 0.1515 0.1515 -0.5185 -0.33
0.1987 0.1515 -0.1137 -0.6237 -0.25
1.0017
0.0826 -0.2015 0.2429 0.3429 0.05
0.2673 -0.2015 -0.3215 0.4185 0.37
0.0960 -0.2015 -0.2015 -0.3215 -0.06
0.0574 -0.2015 -0.3530 -0.4730 -0.06
0.5033
0.0352 0.1200 0.2323 0.2823 0.02
0.1815 0.1200 0.1200 0.5900 0.23
0.1474 0.1200 0.1200 -0.0800 -0.10
0.2673 0.1200 0.3215 -0.4185 -0.37
0.6314
1 2 3 4 5 6 7
Sentido de
circuito tramo Ѳ (pulg) L (m) Q0(L/s) sf (m/M) Hf(m)
flujo
3a5 2 45.12 -0.13 -1 -0.0002 -0.0072
5 a 10 2 55.54 -0.01 -1 0.0000 0.0000
I 10 a 9 2 98.37 -1.58 -1 -0.0151 -1.4862
9a2 2.5 61.51 3.68 1 0.0243 1.4934
2a3 2.5 95.53 3.86 1 0.0265 2.5335
0.0000
3a4 2 94.25 0.94 1 0.0057 0.5379
4a6 2 36.33 0.45 1 0.0014 0.0525
II
6a5 2 87.25 -1.03 -1 -0.0068 -0.5975
5a3 2 45.12 0.13 1 0.0002 0.0072
0.0000
5a6 2 87.25 1.03 1 0.0068 0.5975
6a7 2 24.43 0.86 1 0.0049 0.1187
III 7 a 11 2 51.61 0.25 1 0.0005 0.0252
11 a 10 2 89.64 -0.93 -1 -0.0057 -0.5077
10 a 5 2 55.54 -0.79 -1 -0.0042 -0.2337
0.0000
7a8 2 38.57 0.52 1 0.0019 0.0742
8 a 12 2 48.82 0.39 1 0.0011 0.0551
IV
12 a 11 2 51.51 -0.53 -1 -0.0020 -0.1040
11 a 7 2 51.61 -0.25 -1 -0.0005 -0.0252
0.0000
9 a 10 2 98.37 1.58 1 0.0151 1.4862
10 a 15 2 55.64 0.38 1 0.0011 0.0610
V
15 a 14 2 98.74 -0.59 -1 -0.0024 -0.2396
14 a 9 2 52.83 -2.07 -1 -0.0248 -1.3075
0.0000
10 a 11 2 89.64 0.93 1 0.0057 0.5077
11 a 16 2 57.44 0.65 1 0.0029 0.1653
VI
16 a 15 2 90.51 -0.52 -1 -0.0019 -0.1759
15 a 10 2 55.64 -1.19 -1 -0.0089 -0.4971
0.0000
11 a 12 2 51.51 0.53 1 0.0020 0.1040
12 a 17 2 55.37 0.56 1 0.0022 0.1234
VII
17 a 16 2 69.62 -0.34 -1 -0.0009 -0.0621
16 a 11 2 57.44 -0.65 -1 -0.0029 -0.1653
0.0000
14 a 19 2 54.52 0.66 1 0.0030 0.1649
19 a 18 2 102.12 0.45 1 0.0014 0.1479
VIII
18 a 13 2 50.71 -0.49 -1 -0.0018 -0.0890
13 a 14 2 64.57 -0.71 -1 -0.0035 -0.2239
0.0000
14 a 15 2 98.74 0.59 1 0.0024 0.2396
15 a 20 2 53.86 0.58 1 0.0024 0.1275
IX
20 a 19 2 98.52 -0.54 -1 -0.0021 -0.2021
19 a 14 2 54.52 -0.66 -1 -0.0030 -0.1649
0.0000
15 a 16 2 90.51 0.52 1 0.0019 0.1759
16 a 21 2 53.44 0.47 1 0.0016 0.0839
X
21 a 20 2 90.13 -0.45 -1 -0.0015 -0.1324
20 a 15 2 53.86 -0.58 -1 -0.0024 -0.1275
0.0000
16 a 17 2 69.62 0.34 1 0.0009 0.0621
17 a 22 2 53.38 0.42 1 0.0013 0.0679
XI
22 a 21 2 89.59 -0.25 -1 -0.0005 -0.0460
21 a 16 2 53.44 -0.47 -1 -0.0016 -0.0839
0.0000
C= 140

SE REALIZARON 24 CORRIDAS
12 13 Elevacion
8 9 10 Elevacion Nudos
11 Piezometric
Aguas a
Aguas
Hf/Q ∆Q ∆Qfinal Q1 V (m/seg) Aguas abajo
Arriba Arriba
0.0531 0.0000 0.0000 -0.1348 -0.07 140.77 132.27 156.22
0.0052 0.0000 0.0000 -0.0068 0.00 132.27 120.77 156.23
0.9390 0.0000 0.0000 -1.5828 -0.78 120.77 126.77 156.23
0.4058 0.0000 0.0000 3.6804 1.16 126.77 136.77 157.71
0.6563 0.0000 0.0000 3.8604 1.22 136.77 140.77 156.22
1.4030
0.5752 0.0000 0.0000 0.9352 0.46 140.77 136.77 156.22
0.1180 0.0000 0.0000 0.4452 0.22 136.77 132.27 155.68
0.5790 0.0000 0.0000 -1.0320 -0.51 132.27 132.27 155.63
0.0531 0.0000 0.0000 0.1348 0.07 132.27 140.77 156.23
1.3252
0.5790 0.0000 0.0000 1.0320 0.51 132.27 132.27 156.23
0.1385 0.0000 0.0000 0.8572 0.42 132.27 126.77 155.63
0.1019 0.0000 0.0000 0.2478 0.12 126.77 114.77 155.51
0.5451 0.0000 0.0000 -0.9313 -0.46 114.77 120.77 155.41
0.2947 0.0000 0.0000 -0.7932 -0.39 120.77 132.27 154.86
1.6592
0.1428 0.0000 0.0000 0.5194 0.26 126.77 125.27 156.23
0.1415 0.0000 0.0000 0.3894 0.19 125.27 113.77 156.15
0.1950 0.0000 0.0000 -0.5332 -0.26 113.77 114.77 156.10
0.1019 0.0000 0.0000 -0.2478 -0.12 114.77 126.77 156.20
0.5811
0.9390 0.0000 0.0000 1.5828 0.78 126.77 120.77 154.86
0.1591 0.0000 0.0000 0.3832 0.19 120.77 108.77 153.38
0.4067 0.0000 0.0000 -0.5889 -0.29 108.77 115.77 153.32
0.6326 0.0000 0.0000 -2.0668 -1.02 115.77 126.77 153.56
2.1374
0.5451 0.0000 0.0000 0.9313 0.46 120.77 114.77 156.20
0.2559 0.0000 0.0000 0.6459 0.32 114.77 105.27 155.69
0.3368 0.0000 0.0000 -0.5225 -0.26 105.27 108.77 155.53
0.4172 0.0000 0.0000 -1.1915 -0.59 108.77 120.77 155.70
1.5550
0.1950 0.0000 0.0000 0.5332 0.26 114.77 113.77 153.56
0.2194 0.0000 0.0000 0.5626 0.28 113.77 104.27 153.45
0.1811 0.0000 0.0000 -0.3428 -0.17 104.27 105.27 153.33
0.2559 0.0000 0.0000 -0.6459 -0.32 105.27 114.77 153.39
0.8514
0.2486 0.0000 0.0000 0.6635 0.33 115.77 104.27 155.70
0.3319 0.0000 0.0000 0.4457 0.22 104.27 114.77 155.54
0.1800 0.0000 0.0000 -0.4943 -0.24 114.77 120.27 155.39
0.3134 0.0000 0.0000 -0.7143 -0.35 120.27 115.77 155.48
1.0739
0.4067 0.0000 0.0000 0.5889 0.29 115.77 108.77 153.39
0.2194 0.0000 0.0000 0.5811 0.29 108.77 99.77 153.15
0.3757 0.0000 0.0000 -0.5379 -0.27 99.77 104.27 153.02
0.2486 0.0000 0.0000 -0.6635 -0.33 104.27 115.77 153.23
1.2504
0.3368 0.0000 0.0000 0.5225 0.26 108.77 105.27 155.48
0.1803 0.0000 0.0000 0.4656 0.23 105.27 96.77 155.30
0.2948 0.0000 0.0000 -0.4490 -0.22 96.77 99.77 155.22
0.2194 0.0000 0.0000 -0.5811 -0.29 99.77 108.77 155.35
1.0312
0.1811 0.0000 0.0000 0.3428 0.17 105.27 104.27 153.23
0.1635 0.0000 0.0000 0.4154 0.20 104.27 94.77 153.16
0.1809 0.0000 0.0000 -0.2546 -0.13 94.77 96.77 153.10
0.1803 0.0000 0.0000 -0.4656 -0.23 96.77 105.27 153.14
0.7057

EALIZARON 24 CORRIDAS
Altura de
Presion
Aguas
Aguas abajo Aguas abajo
Arriba
156.23 15.45 23.96
156.23 23.96 35.46
157.71 35.46 30.94
156.22 30.94 19.45
153.69 19.45 12.92

155.68 35.46 18.91


155.63 18.91 23.36
156.23 23.36 23.96
156.22 23.96 15.45

155.63 19.45 23.36


155.51 23.36 28.74
155.41 23.36 40.64
154.86 40.64 34.09
154.57 34.09 22.30

156.15 23.96 30.88


156.10 30.88 42.33
156.20 42.33 41.43
156.23 41.43 29.46

153.38 34.09 32.61


153.32 32.61 44.55
153.56 44.55 37.79
154.86 37.79 28.09

155.69 41.43 40.92


155.53 40.92 50.26
155.70 50.26 46.93
156.20 46.93 35.43

153.45 37.79 39.68


153.33 39.68 49.06
153.39 49.06 48.12
153.56 48.12 38.79

155.54 46.93 51.27


155.39 51.27 40.62
155.48 40.62 35.21
155.70 35.21 39.93
153.15 48.12 44.38
153.02 44.38 53.25
153.23 53.25 48.96
153.39 48.96 37.62

155.30 35.21 50.03


155.22 50.03 58.45
155.35 58.45 55.58
155.48 55.58 46.71

153.16 48.96 48.89


153.10 48.89 58.33
153.14 58.33 56.37
153.23 56.37 47.96
1 2 3 4 5 6 7 8 9 10 Elevacion Nudos Elevacion Piezometrica Altura de Presion
Sentido de Aguas Aguas Aguas PROFUNDIDAD DE
circuito tramo Ѳ (pulg) L (m) Q0(L/s) sf (m/M) Hf(m) Hf/Q ∆Q ∆Qfinal Q1 V (m/seg) Aguas abajo Aguas abajo Aguas abajo
flujo Arriba Arriba Arriba EXCAVACION
3a5 2 45.12 -0.13 -1 -0.0002 -0.0072 0.0531 0.0000 0.0000 -0.1348 -0.07 138.97 130.47 153.97 153.98 15.00 23.51 1.8 m
5 a 10 2 55.54 -0.01 -1 0.0000 0.0000 0.0052 0.0000 0.0000 -0.0068 0.00 130.47 118.97 153.98 153.98 23.51 35.01 1.5 m
I 10 a 9 2 98.37 -1.58 -1 -0.0151 -1.4862 0.9390 0.0000 0.0000 -1.5828 -0.78 118.97 124.97 153.98 155.46 35.01 30.49 1 m
9a2 2.5 61.51 3.68 1 0.0243 1.4934 0.4058 0.0000 0.0000 3.6804 1.16 124.97 134.97 155.46 153.97 30.49 19.00
2a3 2.5 95.53 3.86 1 0.0265 2.5335 0.6563 0.0000 0.0000 3.8604 1.22 134.97 138.97 153.97 151.44 19.00 12.47
0.0000 1.4030
3a4 2 94.25 0.94 1 0.0057 0.5379 0.5752 0.0000 0.0000 0.9352 0.46 138.97 134.97 153.97 153.43 35.01 18.46
4a6 2 36.33 0.45 1 0.0014 0.0525 0.1180 0.0000 0.0000 0.4452 0.22 134.97 130.47 153.43 153.38 18.46 22.91
II
6a5 2 87.25 -1.03 -1 -0.0068 -0.5975 0.5790 0.0000 0.0000 -1.0320 -0.51 130.47 130.47 153.38 153.98 22.91 23.51
5a3 2 45.12 0.13 1 0.0002 0.0072 0.0531 0.0000 0.0000 0.1348 0.07 130.47 138.97 153.98 153.97 23.51 15.00
0.0000 1.3252
5a6 2 87.25 1.03 1 0.0068 0.5975 0.5790 0.0000 0.0000 1.0320 0.51 130.47 130.47 153.98 153.38 19.00 22.91
6a7 2 24.43 0.86 1 0.0049 0.1187 0.1385 0.0000 0.0000 0.8572 0.42 130.47 124.97 153.38 153.26 22.91 28.29
III 7 a 11 2 51.61 0.25 1 0.0005 0.0252 0.1019 0.0000 0.0000 0.2478 0.12 124.97 113.77 153.26 153.16 22.91 39.39
11 a 10 2 89.64 -0.93 -1 -0.0057 -0.5077 0.5451 0.0000 0.0000 -0.9313 -0.46 113.77 118.97 153.16 152.61 39.39 33.64
10 a 5 2 55.54 -0.79 -1 -0.0042 -0.2337 0.2947 0.0000 0.0000 -0.7932 -0.39 118.97 130.47 152.61 152.32 33.64 21.85
0.0000 1.6592
7a8 2 38.57 0.52 1 0.0019 0.0742 0.1428 0.0000 0.0000 0.5194 0.26 124.97 123.47 153.98 153.90 23.51 30.43
8 a 12 2 48.82 0.39 1 0.0011 0.0551 0.1415 0.0000 0.0000 0.3894 0.19 123.47 111.97 153.90 153.85 30.43 41.88 La válvula reductora de presión Genebre Redux funciona con un
IV
12 a 11 2 51.51 -0.53 -1 -0.0020 -0.1040 0.1950 0.0000 0.0000 -0.5332 -0.26 111.97 112.97 153.85 153.95 41.88 40.98 pistón, a una presión máxima de 25bar y entre 0 y 130°C de
11 a 7 2 51.61 -0.25 -1 -0.0005 -0.0252 0.1019 0.0000 0.0000 -0.2478 -0.12 112.97 124.97 153.95 153.98 40.98 29.01 temperatura. La presión de salida es regulable según la medida
0.0000 0.5811 del reductor (0.5 a 5bar para ½ y ¾ de pulgada, y 0.5 a 8bar para
9 a 10 2 98.37 1.58 1 0.0151 1.4862 0.9390 0.0000 0.0000 1.5828 0.78 124.97 118.97 152.61 151.13 33.64 32.16 1 a 4 pulgadas). Está hecha de bronce, con asiento en acero
10 a 15 2 55.64 0.38 1 0.0011 0.0610 0.1591 0.0000 0.0000 0.3832 0.19 118.97 106.97 151.13 151.07 32.16 44.10 inoxidable 304, tiene toma de manómetros laterales de ¼ de
V
15 a 14 2 98.74 -0.59 -1 -0.0024 -0.2396 0.4067 0.0000 0.0000 -0.5889 -0.29 106.97 113.97 151.07 151.31 44.10 37.34 pulgada y es apropiada para usos con agua y aire comprimido.
14 a 9 2 52.83 -2.07 -1 -0.0248 -1.3075 0.6326 0.0000 0.0000 -2.0668 -1.02 113.97 124.97 151.31 152.61 37.34 27.64
0.0000 2.1374
10 a 11 2 89.64 0.93 1 0.0057 0.5077 0.5451 0.0000 0.0000 0.9313 0.46 118.97 112.97 153.95 153.44 40.98 40.47
11 a 16 2 57.44 0.65 1 0.0029 0.1653 0.2559 0.0000 0.0000 0.6459 0.32 112.97 104.27 153.44 153.28 40.47 49.01
VI
16 a 15 2 90.51 -0.52 -1 -0.0019 -0.1759 0.3368 0.0000 0.0000 -0.5225 -0.26 104.27 106.97 153.28 153.45 49.01 46.48
15 a 10 2 55.64 -1.19 -1 -0.0089 -0.4971 0.4172 0.0000 0.0000 -1.1915 -0.59 106.97 118.97 153.45 153.95 46.48 34.98
0.0000 1.5550
11 a 12 2 51.51 0.53 1 0.0020 0.1040 0.1950 0.0000 0.0000 0.5332 0.26 112.97 111.97 151.31 151.20 37.34 39.23
12 a 17 2 55.37 0.56 1 0.0022 0.1234 0.2194 0.0000 0.0000 0.5626 0.28 111.97 102.47 151.20 151.08 39.23 48.61
VII
17 a 16 2 69.62 -0.34 -1 -0.0009 -0.0621 0.1811 0.0000 0.0000 -0.3428 -0.17 102.47 103.47 151.08 151.14 48.61 47.67
16 a 11 2 57.44 -0.65 -1 -0.0029 -0.1653 0.2559 0.0000 0.0000 -0.6459 -0.32 103.47 112.97 151.14 151.31 47.67 38.34
0.0000 0.8514
14 a 19 2 54.52 0.66 1 0.0030 0.1649 0.2486 0.0000 0.0000 0.6635 0.33 113.97 103.27 153.45 153.29 46.48 50.02
19 a 18 2 102.12 0.45 1 0.0014 0.1479 0.3319 0.0000 0.0000 0.4457 0.22 103.27 112.97 153.29 153.14 50.02 40.17
VIII
18 a 13 2 50.71 -0.49 -1 -0.0018 -0.0890 0.1800 0.0000 0.0000 -0.4943 -0.24 112.97 118.47 153.14 153.23 40.17 34.76
13 a 14 2 64.57 -0.71 -1 -0.0035 -0.2239 0.3134 0.0000 0.0000 -0.7143 -0.35 118.47 113.97 153.23 153.45 34.76 39.48
0.0000 1.0739
14 a 15 2 98.74 0.59 1 0.0024 0.2396 0.4067 0.0000 0.0000 0.5889 0.29 113.97 106.97 151.14 150.90 47.67 43.93
15 a 20 2 53.86 0.58 1 0.0024 0.1275 0.2194 0.0000 0.0000 0.5811 0.29 106.97 98.77 150.90 150.77 43.93 52.00
IX
20 a 19 2 98.52 -0.54 -1 -0.0021 -0.2021 0.3757 0.0000 0.0000 -0.5379 -0.27 98.77 102.47 150.77 150.98 52.00 48.51
19 a 14 2 54.52 -0.66 -1 -0.0030 -0.1649 0.2486 0.0000 0.0000 -0.6635 -0.33 102.47 113.97 150.98 151.14 48.51 37.17
0.0000 1.2504
15 a 16 2 90.51 0.52 1 0.0019 0.1759 0.3368 0.0000 0.0000 0.5225 0.26 106.97 103.47 153.23 153.05 34.76 49.58
16 a 21 2 53.44 0.47 1 0.0016 0.0839 0.1803 0.0000 0.0000 0.4656 0.23 103.47 94.97 153.05 152.97 49.58 58.00
X
21 a 20 2 90.13 -0.45 -1 -0.0015 -0.1324 0.2948 0.0000 0.0000 -0.4490 -0.22 94.97 97.97 152.97 153.10 58.00 55.13
20 a 15 2 53.86 -0.58 -1 -0.0024 -0.1275 0.2194 0.0000 0.0000 -0.5811 -0.29 97.97 106.97 153.10 153.23 55.13 46.26
0.0000 1.0312
16 a 17 2 69.62 0.34 1 0.0009 0.0621 0.1811 0.0000 0.0000 0.3428 0.17 103.47 102.47 150.98 150.91 48.51 48.44
17 a 22 2 53.38 0.42 1 0.0013 0.0679 0.1635 0.0000 0.0000 0.4154 0.20 102.47 92.97 150.91 150.85 48.44 57.88
XI
22 a 21 2 89.59 -0.25 -1 -0.0005 -0.0460 0.1809 0.0000 0.0000 -0.2546 -0.13 92.97 94.97 150.85 150.89 57.88 55.92
21 a 16 2 53.44 -0.47 -1 -0.0016 -0.0839 0.1803 0.0000 0.0000 -0.4656 -0.23 94.97 103.47 150.89 150.98 55.92 47.51
0.0000 0.7057
C= 140

SE REALIZARON 24 CORRIDAS

También podría gustarte