Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Manual Tecnico Inverter
Manual Tecnico Inverter
rev.1 (19-01-06)
1. GAMA DE PRODUCTOS
2
GAMA DOMESTICA INVERTER
Cod.Eurofred Des. comercial Ref Ref.Pro.
ASH9LSACW
3NGG8045 ASG9UI R410A
AOH9LSAC
ASH12LSACW
3NGG8050 ASG9UI R410A
AOH12LSAC
3
GAMA COMERICAL INVERTER
ABH18LBAJ
3NGG8320 ABG18UI R410A
Suelo/Techo AOH18LMAKL
Inverter 3NGG8330 ABG24UI R410A
ABH24LBAJ
AOH24LMAL
AUH18LBAB
3NGG8430 AUG18UI R410A
AOH18LMAKL
AUH24LUAR
3NGG8435 AUG24UI R410A
AOH24LMAKL
Cassette AUH30LUAS
3NGG8440 AUG30UI R410A
Inverter AOH30LMAWL
AUH36LUAS
3NGG8445 AUG36UI R410A
AOH36LMAWL
AUH45LUAS
3NGG8450 AUG45UI R410A
AOH45LJBYL
ARH18LUAD
3NGG8530 ACG18UI R410A
AOH18LMAKL
ARH24LUAN
3NGG8535 ACG24UI R410A
AOH24LMAKL
ARH30LUAN
3NGG8540 ACG30UI R410A
AOH30LMAWL
Conductos ARH36LUAN
3NGG8545 ACG36UI R410A
Inverter AOH36LMAWL
ARH45LUAN
3NGG8555 ACG45UI L R410A
AOH45LJBYL
ARH45LUAK
3NGG8550 ACG45UI R410A
AOH45LJAYL
ARH54LUAK
3NGG8560 ACG54UI R410A
AOH54LJAYL
4
TABLA DE CARACTERISTCAS GENERALES
AWH14LSAZ
3NGG8055 15 8 - 15 - 10 ~43 -10~24 6.35/9.52
AOY14LSAWC
AWH17LSAZ
3NGG8060 15 8 - 15 - 10 ~43 -10~24 6.35/9.52
Ceiling Wall AOH17LSAWC
Inverter 3NGG8075
AWH24LBAJ
25 15 - 10 50g/m 0~43 -10~21 9.52/15.88
AOH24LMAL
AWH30LBAJ
3NGG8080 25 15 - 10 50g/m 0~43 -10~21 9.52/15.88
AOH30LMAL
ABH18LBAJ
3NGG8320 25 15 5 10 20g/m 0~43 -10~24 6.35/12.7
Suelo/Techo AOH18LMAKL
Inverter 3NGG8330
ABH24LBAJ
25 15 5 10 50g/m 0~43 -10~24 9.52/15.88
AOH24LMAL
AUH18LBAB
3NGG8430 25 15 5 10 20g/m 0~43 -10~24 6.35/12.7
AOH18LMAKL
AUH24LUAR
3NGG8435 25 15 5 10 40g/m 0~43 -10~24 9.52/15.88
AOH24LMAKL
Cassette AUH30LUAS
3NGG8440 50 30 5 15 40g/m -10~43 -10~24 9.52/15.88
Inverter AOH30LMAWL
AUH36LUAS
3NGG8445 50 30 5 15 40g/m -10~43 -10~24 9.52/15.88
AOH36LMAWL
AUH45LUAS
3NGG8450 70 30 5 20 40g/m -15~43 -15~24 9.52/15.88
AOH45LJBYL
ARH18LUAD
3NGG8530 25 15 5 10 20g/m 0~43 -10~24 6.35/12.7
AOH18LMAKL
ARH24LUAN
3NGG8535 25 15 5 10 40g/m 0~43 -10~24 9.52/15.88
AOH24LMAKL
ARH30LUAN
3NGG8540 50 30 5 15 40g/m -10~43 -10~24 9.52/15.88
AOH30LMAWL
Conductos ARH36LUAN
3NGG8545 50 30 5 15 40g/m -10~43 -10~24 9.52/15.88
Inverter AOH36LMAWL
ARH45LUAN
3NGG8555 70 30 5 20 40g/m -15~43 -15~24 9.52/15.88
AOH45LJBYL
ARH45LUAK
3NGG8550 70 30 5 20 40g/m -15~43 -15~24 9.52/15.88
AOH45LJAYL
ARH54LUAK
3NGG8560 70 30 5 20 40g/m -15~43 -15~24 9.52/15.88
AOH54LJAYL
5
2. VENTAJAS INVERTER
6
La mejora del confort
El principal propósito del acondicionador de aire es ofrecer un
aire confortable
residencial, pero todavía hay algún problema derivado del
acondicionador de aire
convencional en bomba de calor.
Sin embargo, utilizando el inverter, esos problemas pueden
resolverse.
Problema 1
La capacidad calorífica disminuye con bajas temperaturas.
Problema 2
Requiere largos periodos de tiempo para alcanzar la temperatura
seleccionada.
Problema 3
La temperatura del recinto baja rápidamente cuando para el
compresor, lo cual
provoca un cambio de temperatura que puede percibir el cuerpo
humano
causando una sensación de incomodidad.
7
Problema 1
La capacidad calorí
calorífica disminuye con bajas temperaturas.
Problema 2
Requiere largos periodos de tiempo para alcanzar la temperatura
seleccionada (unos 40 minutos)
Modelo Convencional Modelo Inverter
Temperatura seleccionada Temperatura seleccionada
Temperatura recinto (ºC.)
8
Problema 3
La temperatura del recinto cae rá
rápidamente cuando para el compresor,
creando una gran rango de temperaturas en el recinto, que el cuerpo
cuerpo
humano puede apreciar causá
causándole una desagradable sensació
sensación.
Tiempo Tiempo
Otras características
-Baja cresta de arranque del compresor.
9
3. COMPONENTES PRINCIPALES
10
¿Qué es el inverter?
Inverter y Converter
Converter Dispositivo para convertir la corriente alterna en contínua.
Inverter Dispositivo para convertir la corriente contínua en alterna.
11
DIAGRAMA PARTES INVERTER I-PAM
Fan motor
Remote control
Indicator
Capacitor
4
Fan motor
way valve
Compressor
Outdoor unit
12
DIAGRAMA DE CONTROL I-PAM
Módulo Inverter
Potencia (AFM)
Filtro Activo de
Puente Diodos
b
(IPM)
AC d
Bobina de V
Alimentación
Choque Motor
Eléctrica
Condensador W
a c N e
a) Se cambia la diferencia de potencial a una onda positiva usando un puente de diodos conectado a la entrada de suministro de AC
(Rectificación en la onda positiva)
b) La bobina de choque conserva constante la variación de corriente y quita las pulsaciones del rectificador de corriente DC.
c) El filtro activo de potencia suprime la alta frecuencia de harmónicos generados durante la rectificación y mejora el factor de potencia.
d) Mediante el condensador, el voltaje de salida del filtro activo de potencia se convierte en DC estable..
e) El modulo inverter, compuesto de 6 transistores alimentados del voltaje de salida del AFM, modifica la alimentación del motor
mediante el control PWM ó PAM.
13
310V DC aprox
380V DC con el compresor
en funcionamiento.
AOH9/12LSAC
De 30 a 190V AC aprox
a frecuencia variable
310V DC aprox
380V DC con el compresor
P UV W N
en funcionamiento.
INVERTER
POWER
MODULE
MAIN
CONTROL PCB
L1
P
L2
ACTIVE FILTER N
MODULE (AFM)
+
DIODO BRIDGE
-
14
SPLIT PARED INVERTER
AOH9LSACW/AOY9LSACW/RO-9LA/HOW-9LA
15
310V DC aprox
380V DC con el compresor AOH14/18LFBC
en funcionamiento.
230V DC aprox.
De 30 a 190V AC aprox
a frecuencia variable
230V AC
310V DC aprox
380V DC con el compresor
en funcionamiento.
230V AC
16
SPLIT PARED INVERTER
AOH14LFBC/AOY14LFBC/RO-14LB/HOW-14LB
9AGF01171 (K02DS-0400HUE-TR0)
IPM (TR PCB ASSY) * En despieces aparece como: INVERTER PCB Assy
17
AOH45/54LJAYL
De 30 a 190V AC aprox
a frecuencia variable
230V DC aprox.
310V DC aprox
380V DC con el compresor
en funcionamiento.
230V AC
230V AC
18
COMERCIAL INVERTER
AOH45LJAYL/AOY45LJAYL/RO-45LA/HO-45LA
9AGF00947 K04BA-0400HUE-PO)
POWER PCB ASSY (FILTER PCB) * En despieces aparece como: INVERTER PCB Assy
19
DIAGRAMA PARTES INVERTER V-PAM
Fan motor
Remote control
Indicator
Diode bridge
Capacitor
4
Fan motor
way valve
Compressor
Outdoor unit
20
DIAGRAMA DE CONTROL V-PAM
Módulo Inverter
Puente Diodos
b
Condensador
Bobina de U
(IPM)
d
AC Choque
c V
Power supply POWER FACTOR Motor
CONVERTER CIRCUIT W
a) Se cambia la diferencia de potencial a una onda positiva usando un puente de diodos conectado a la entrada de suministro de AC
(Rectificación en la onda positiva)
b) La bobina de choque conserva constante la variación de corriente y quita las pulsaciones del rectificador de corriente DC.
c) POWER FACTOR CONVERTER CIRCUIT (PFC) suprime la alta frecuencia de armónicas.
d) Mediante el condensador, el voltaje de salida del filtro activo de potencia se convierte en DC estable...
e) El modulo inverter, compuesto de 6 transistores alimentados del voltaje de salida del AFM, modifica la alimentación del motor
mediante el control PWM.
21
AOH9/12LFBC
De 30 a 190V AC aprox
a frecuencia variable
MAIN
CONTROL PCB
•DIODE BRIDGE
•POWER FACTOR
CONVERTER CIRCUIT
•CAPACITOR
•INVERTER POWER
MODULE
230V AC
22
SPLIT PARED INVERTER
AOH9LFBC/AOY9LFBC/RO-9LB/HOW-9LB
9AGF01070 (K04DT-0400HUE-C1)
23
AC INVERTER
Motor
AC Motor
El compresor AC es un motor de inducción trifásico. Se crea un campo magnético
giratorio en el estator al aplicarle el voltaje que suministra el módulo inverter (mediante
el control PWM). La corriente inducida en el rotor crea el par de giro del compresor.
La velocidad de rotación del compresor se puede variar cambiando la frecuencia del
voltaje que envía el módulo inverter al compresor, controlado mediante el control PWM.
La frecuencia y el voltaje tienen una relación lineal.
24
DC INVERTER
Motor
BLDC Motor (DC Inverter)
El rotor del compresor DC está hecho de imanes permanentes. En el estator del motor se
crea un campo magnético giratorio aplicando el voltaje que se obtiene del módulo inverter.
La atracción y repulsión entre el campo magnético giratorio y el campo magnético
permanete crea el par de giro del compresor.
Se necesita controlar la posición del rotor (campo magnético permanente) para hacerlo
conincidir con la polaridad del campo magnético giratorio. Para poder controlar esta
posición del rotor, se realiza la detección midiendo la fuerza contra-electromotriz que se
origina en el estator por el paso del rotor.
La velocidad de giro del compresor se puede controlar cambiando el voltaje, mediante los
métodos de control PAM o PWM .
25
4. FUNCIONAMIENTO
26
CONTROL DE LA CAPACIDAD EN FRIO
AS*9-12LSAC y AS*9-12-14-18LSBC
27
CONTROL CAPACIDAD EN CALEFACCION
AS*9-12LSAC y AS*9-12-14-18LSBC
28
PROTECCIONES
AS*9-12LSAC y AS*9-12-14-18LSBC
TEMPERATURA DE DESCARGA
•Temp. Descarga > 104ºC entra protección ---> compresor baja 20Hz cada 2 min.
•Temp. Descarga > 110ºC ----> compresor para.
•Temp. Descarga < 101ºC ----> final de la protección.
29
ANTIFREEZING (Cooling y Dry mode)
•La velocidad del compresor se reduce cuando la temperatura de la batería interior
es inferior a la Temperatura I de la Tabla 19. Se desactiva cuando está por encima
de la Temperatura II.
30
•PROTECCION ALTA TEMPERATURA (Heating mode)
•En modo calefacción, la velocidad del compresor se controla para no sobrepasar
los valores de temperatura establecidos para la batería interior. Ver Fig.11.
31
5. CODIGOS DE ERROR
32
AUTODIAGNOSTICO - TABLA 1
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
>>paro permanente
Error ventilador unidad Parpadeos 0,1 0,5 seg / 6 veces Si la corriente del ventilador es anormal o se detecta
exterior (solo los DC) seg. un error de localización
>>paro permanente
Error motor 0,5 seg / 6 veces Parpadeos 0,1 Error bloqueo ventilador int. Parpadeos 0,1 0,5 seg / 2 veces El giro detectado es 0 rpm 56 seg después de la puesta
ventilador unidad seg. seg. en marcha, o cuando se selecciona otra velocidad del
interior ventilador
>>paro permanente (reinicia con el mando)
Error velocidad giro anormal Parpadeos 0,1 0,5 seg / 3 veces El giro detectado es 1/3 de la velocidad seleccionada después
seg. de la puesta en marcha, o cuando se selecciona otra
velocidad del ventilador
>>paro permanente (reinicia con el mando)
Error de ciclo 0,5 seg / 7 veces Parpadeos 0,1 Temperatura descarga Parpadeos 0,1 0,5 seg / 2 veces Protección de temperatura de descarga
de refrigerante seg. compresor anormal seg. (Temperatura de descarga es 110ºC)
>>paro permanente
Protección alta presión Parpadeos 0,1 0,5 seg / 3 veces Se activa la protección debido a una excesiva alta presión
en frío seg. en funcionamiento en frío
(temperatura tubo de 65ºC o 67ºC)
>> compresor, ventilador ext: OFF (desaparece en 3 min)
Otros Errores 0,5 seg / 8 veces Parpadeos 0,1 Error voltaje filtro activo Parpadeos 0,1 0,5 seg / 2 veces El voltaje de salida en el filtro activo es erróneo
seg. anormal (3º vez) seg.
>>paro permanente
Error filtro activo Parpadeos 0,1 0,5 seg / 3 veces Error del filtro activo o un corte instantáneo es detectado
anormal (1º vez) seg.
>> compresor, ventilador ext: OFF (desaparece en 3 min)
Error circuito PFC Parpadeos 0,1 0,5 seg / 4 veces Se detecta excesivo voltaje DC o corriente del circuito PFC
seg. al modulo inverter.
>>paro permanente
33
AUTODIAGNOSTICO - TABLA 2
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
# Sobrecarga de corriente del compresor (Stop permanente) OFF 6 veces OFF 6 VECES
# Temperatura de desescarche anormal (Stop permanente) OFF 7 veces OFF 7 VECES
# Sonda temperatura anormal OFF 8 veces OFF 8 VECES
# Error localización del rotor del compresor (Stop permanente) OFF 12 veces OFF 12 VECES
# CT anormal (Stop permanente) OFF 14 veces OFF 14 VECES
# Voltaje del filtro activo anormal ((Stop permanente) OFF 21 veces OFF 21 VECES
Cuando la unidad está conectada a la corriente, el led está encendido ON
34
AUTODIAGNOSTICO - TABLA 3
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
Indoor unil Operation : 0.5 sec 2 times 22 to 25 Room temperature thermistor faulty Operation: 0.1 sec
thermislor abnormal Timer: 0.1 sec Sonda ambiente unidad interior Timer: 0.5 sec 2 times 22
Outdoor unil Operation : 0.5 sec 3 times 32 to 37 Outlet thermistor faulty Operation : 0 1 sec
thermistor abnormal Timer: 0.1 sec Sonda temperatura de descarga Timer: 0.5 sec 2 times 32
Indoor unit control Operation: 0.5 sec 4 times 42 to 48 Filter reset-forced automatic switch faulty Operation: 0.1 sec
unit faulty Timer: 0.1 sec Interruptor encendido durante 30 seg seguidos Timer: 0.5 sec 2 times 42
Outdoor unit control Operation : 0.5 sec 5 limes 52 to 57 Transistor module overcurrent Operation: 0.1 sec
unit faulty Timer: 0 1 sec Protección IPM Timer: 0.5 sec 2 times 52
Ouldoor unit Operation : 0.5 sec 5 times 52 to 57 Compressor position abnormal Operation: 0.1 sec
thermistor abnormal Timer: 0.1 sec No se detecta la posicion del rotor del compresor Timer: 0.5 sec 5 times 55
Indoor unlt fan Operation : 0.5 sec 6 limes 62 to 63 Fan motor locked Operation :0.1 sec
motor abnormal Timer: 0.1 sec Bloqueo ventilador interior Timer: 0.5 sec 2 times 62
rceingerating cycie Operation : 0.5 sec 7 times 72 to 75 Discharge temperatura abnormal Operation: 0 1 sec
abnormal Timer: 0.1 sec Temperatura de descarga anormal Timer: 0.5 sec 2 times 72
Aclíve filler abnorma Operation : 0.5 sec 8 times 82 to 83 Active filter voltage detection abnormal (when operated 2 times) Operation: 0 1 sec
Timer: 0.1 sec Error voltaje filtro activo < 80 VDC o >380 VDC (2 veces en 40 seg) Timer: 0.5 sec 2 times 82
Active filter voltage detection abnormal (1 time instant operation) Operation: 0.1 sec
Error voltaje filtro activo (corte instantaneo) Timer: 0.5 sec 3 times 83
Outdoor unit control Operation: 0.1 sec Ab EEPROM placa exterior defectuosa
unit board faulty Timer 0.1 sec
Dash: 0.1 sec Ab
UV negativo ion: 0.1 sec
35
AUTODIAGNOSTICO - TABLA 4
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELOS CORRESPONDIENTES: AW*24LBAJ - AW*30LBAJ
Error display
Error contents / CONTENIDO DE ERRORES OPERATION TIMER SWING
(RED) (GREEN) (ORANGE)
Indoor unit circuit board error (EEPROM)
Error circuito placa unidad interior (EEPROM)
Indoor unit room temperature sensor wire opened
2 times
Sonda ambiente unidad interior abierta
Indoor unit room temperature sensor wire short circuited
2 times
Sonda ambiente unidad interior en corto
Indoor unit piping sensor wire opened
3 times
Sonda tubo unidad interior abierto
Indoor unit piping sensor short circuited
3 times
Sonda tubo unidad interior en corto
Drain pump error
4 times
Alarma bomba condensados
Reverse signal error (outdoor unit ---> indoor unit)
5 times
Error de comunicación de unidad exterior a unidad interior
Forward signal error ( indoor unit ---> outdoor unit)
5 times
Error de comunicación de unidad interior a unidad exterior
Indoor unit fan error
6 times
Error ventilador unidad interior
Outdoor unit piping sensor
3 times
Sonda tubo unidad exterior
Outdoor unit outdoor temperature sensor error
4 times
Sonda ambiente unidad exterior
Outdoor unit discharge temperature sensor error
5 times
Sonda tubo de descarga
Outdoor unit compressor temperature sensor error
9 times
Sonda temperatura compresor
IPM error
10 times
Error del modulo IPM
CT error
11 times
Error CT (transformador de corriente)
Active Filter Module (AFM) error
12 times
Error de filtro activo de potencia (AFM)
Compressor rotor position cannot detect
13 times
No se detecta la posicion del rotor del compresor
Outdoor fan motor error
14 times
Error ventilador unidad exterior
PARPADEO RAPIDO :
PARPADEO LENTO :
APAGADO :
36
AUTODIAGNOSTICO - TABLA 5
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELO CORRESPONDIENTES: U.I. MULTI INVERTER (R410A)
ASH7LMACW - ASH9LMACW - ASH12LMACW
Large division indication Small division indication is indicated by pushing TEST RUN
Error display Error display
Error contents OPERATION TIMER Error contents OPERATION
TIMER (GREEN)
(RED) (GREEN) (RED)
Indoor unit room temperature sensor error
2 times
Indoor unit sensors error Sonda ambiente unidad interior
2 times
Sondas unidad interior Indoor unit piping sensor wire
3 times
Sonda tubo unidad interior
MANUAL AUTO button error
2 times
Control unit error (indoor unit) Boton MANUAL AUTO
4 times
Control unidad interior Power source Hz decision error
4 times
Error detección frecuencia alimentación
Serial reverse transmission error
2 times
Serial error Error comunicación de unid. exterior a interior
5 times
Error de comunicación Serial forward transmission error
3 times
Error comunicación de unid. exterior a interior
Lock error
2 times
Fan motor error Error bloqueo ventilador int.
6 times
Ventialdor interior R.p.m. Error
3 times
Error velocidad giro anormal
Discharge thermistor error
2 times
Sonda temperatura de descarga
Heat exchanger thermistor error
4 times
Sonda disipador modulo IPM
Outdoor temperature thermistor error
6 times
Outdoor unit sensors error Sonda ambiente unidad exterior
2 times
Sondas unidad exterior Compressor thermistor error
8 times
Sonda temperatura compresor
2 way valve thermistor error
9 times
Sonda temperatura válvula de 2 vías
3 way valve thermistor error
10 times
Sonda temperatura válvula de 3 vías
Pressure switch error Pressure switch error
3 times 2 times
Presostato de alta Presostato alta activado
Control unit error (outdoor unit) Capacity error of connecting indoor unit
4 times 2 times
Control unidad exterior Error de capacidad unid. interioes conectadas
Outdoor unit IPM error
2 times
Inverter error Error del modulo IPM
5 times
Error Inverter Compressor loter location error
5 times
No se detecta posicion del rotor del compresor
: PARPADEO RAPIDO
: PARPADEO LENTO
37
AUTODIAGNOSTICO - TABLA 6
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELOS CORRESPONDIENTES: U.I. MULTI INVERTER F (R410A)
AS*18LBAJ - AS*24LBAJ
AU*12LBAB - AU*14LBAB - AU*18LBAB
AB*14LBAJ - AB*18LBAJ - AB*24LBAJ
Error display
Error contents / CONTENIDO DE ERRORES OPERATION TIMER SWING
(RED) (GREEN) (ORANGE)
Indoor unit circuit board error (EEPROM)
Error circuito placa unidad interior (EEPROM)
Indoor unit room temperature sensor wire opened
2 times
Sonda ambiente unidad interior abierta
Indoor unit room temperature sensor wire short circuited
2 times
Sonda ambiente unidad interior en corto
Indoor unit piping sensor wire opened
3 times
Sonda tubo unidad interior abierto
Indoor unit piping sensor short circuited
3 times
Sonda tubo unidad interior en corto
Drain pump error
4 times
Alarma bomba condensados
Reverse signal error (outdoor unit ---> indoor unit)
5 times
Error de comunicación de unidad exterior a unidad interior
Forward signal error ( indoor unit ---> outdoor unit)
5 times
Error de comunicación de unidad interior a unidad exterior
Indoor unit fan error
6 times
Error ventilador unidad interior
Outdoor unit piping sensor
3 times
Sonda tubo unidad exterior
Outdoor unit outdoor temperature sensor error
4 times
Sonda ambiente unidad exterior
Outdoor unit discharge temperature sensor error
5 times
Sonda temperatura de descarga
Outdoor unit compressor temperature sensor error
8 times
Sonda temperatura compresor
Outdoor unit pressure switch error
9 times
Presostato alta activado
IPM error
10 times
Error del modulo IPM
CT error
11 times
Error CT (transformador de corriente)
Active Filter Module (AFM) error
12 times
Error de filtro activo de potencia (AFM)
Compressor rotor position cannot detect
13 times
No se detecta la posicion del rotor del compresor
Outdoor fan motor error
14 times
Error ventilador unidad exterior
Outdoor unit 2 way valve temperature sensor error
2 times
Error de sonda de temperatura de valvula de 2 vias
Outdoor unit 3 way valve temperature sensor error
3 times
Error de sonda de temperatura de valvula de 3 vias
Idoor unit connection capacity error
4 times
Error de potencia de unidad inteior conectada
Communication error (inverter - multicontroller)
5 times
Error de comunicación (inverter - multicontroller)
PARPADEO RAPIDO :
PARPADEO LENTO :
APAGADO :
38
AUTODIAGNOSTICO - TABLA 7
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELOS CORRESPONDIENTES: U.I. MULTI INVERTER F (R410A)
AR*9LUAB - AR*12LUAD - AR*14LUAD - AR*18LUAD - AR*22LUAD
Error code Error contents
Communication error (indoor unit <----> remote controller)
00
Error de comunicación entre unidad interior y mando por cable
Reverse signal error (outdoor unit ---> indoor unit)
01
Error de comunicación de unidad exterior a unidad interior
Room temperature sensor open
02
Sonda ambiente unidad interior abierta
Room temperature sensor short-circuited
03
Sonda ambiente unidad interior en corto
Indoor heat exchanger temperature sensor open
04
Sonda tubo unidad interior abierta
Indoor heat exchanger temperature sensor short-circuited
05
Sonda tubo unidad interior en corto
Outdoor heat exchanger temperature sensor
06
Sonda tubo unidad exterior
Power source connection error
08 Error alimentación
Float switch operated
09
Alarma bomba condensados
Outdoor temperature sensor
0A
Sonda ambiente unidad exterior
Discharge pipe temperature sensor
0c
Sonda temperatura de descarga
Outdoor high pressure abnormal
0E
Protección alta presión en frío
Model abnormal
11
Modelos incompatibles
Indoor fan abnormal
12
Error ventilador unidad interior
Forward signal error ( indoor unit ---> outdoor unit)
13
Error de comunicación de unidad interior a unidad exterior
Outdoor EEPROM abnormal
14
Error EEPROM unidad exterior
Compressor temperature sensor
15
Sonda temperatura compresor
Pressure switch error
16
Presostato alta activado
IPM error
17
Error del modulo IPM
CT error
18
Error CT (transformador de corriente)
Active Filter Module (AFM) error
19
Error de filtro activo de potencia (AFM)
Compressor does not operate
1A
Compresor no puede arrancar
Outdoor unit fan error
1b Error ventilador exterior
39
AUTODIAGNOSTICO - TABLA 8
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELO CORRESPONDIENTES: U.E. MULTI INVERTER F 4x1 (R410A)
AO*30LMAW4
Error contents LED A LED B LED C LED D
Communication error (indoor unit A to outdoor unit)
1 time — — —
Error de comunicación (de unidad A a unidad exterior)
Communication error (indoor unit B to outdoor unit)
— 1 time — —
Error de comunicación (de unidad B a unidad exterior)
Communication error (indoor unit C to outdoor unit)
— — 1 time —
Error de comunicación (de unidad C a unidad exterior)
Communication error (indoor unit D to outdoor unit)
— — — 1 time
Error de comunicación (de unidad D a unidad exterior)
Discharge pipe temperature sensor
2 times — — —
Sonda de descarga
Outdoor heat exchanger temperature sensor
3 times — — —
Sonda tubo unidad exterior
Outdoor temperature sensor
4 times — — —
Sonda ambiente unidad exterior
Outdoor 2way valve(A) temperature sensor
5 times — — —
Sonda temperatura válvula de 2 vías A
Outdoor 2way valve(B) temperature sensor
— 5 times — —
Sonda temperatura válvula de 2 vías B
Outdoor 2way valve(C) temperature sensor
— — 5 times —
Sonda temperatura válvula de 2 vías C
Outdoor 2way valve(D) temperature sensor
— — — 5 times
Sonda temperatura válvula de 2 vías D
Outdoor 3way valve(A) temperature sensor
6 times — — —
Sonda temperatura válvula de 3 vías A
Outdoor 3way valve(B) temperature sensor
— 6 times — —
Sonda temperatura válvula de 3 vías B
Outdoor 3way valve(C) temperature sensor
— — 6 times —
Sonda temperatura válvula de 3 vías C
Outdoor 3way valve(D) temperature sensor
— — — 6 times
Sonda temperatura válvula de 3 vías D
Compressor temperature sensor
7 times — — —
Sonda temperatura compresor
Heatsink temperature sensor
8 times — — —
Sonda disipador modulo IPM
Pressure switch A abnomnal
9 times — — —
Presostato alta A activado
Pressure switch B abnomnal
10 times — — —
Presostato alta B activado
Indoor unit connection capacity error
11 times — — —
Error de capacidad unidades inteiroes conectadas
IPM error
12 times — — —
Error del modulo IPM
Comoressor loter location error
13 times — — —
No se detecta la posicion del rotor del compresor
Compressor can not start to operate
14 times — — —
Compresor no puede arrancar
Outdoor fan (upper) motor error
15 times — — —
Error ventilador exterior (ventilador superior)
Outdoor fan abnormal (lower fan)
16 times — — —
Error ventilador exterior (ventilador inferior)
Microcomputer error
17 times — — —
EEPROM error
: PARPADEO LENTO
: APAGADO 40
AUTODIAGNOSTICO - TABLA 9
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELO CORRESPONDIENTES: U.I. MULTI INVERTER 4x1 (R407C)
ASH9QMACW - ASH12QMACW
Error display
Error contents / CONTENIDO DE ERRORES OPERATION TIMER SWING
(RED) (GREEN) (ORANGE)
Forward signal error ( indoor unit ---> outdoor unit)
1 times
Error comunicación de unidad interior a exterior
Outdoor unit discharge temperature
2 times
Sonda temperatura de descarga
Outdoor unit piping sensor error sensor error
3 times
Sonda tubo unidad exterior
Outdoor unit outdoor temperature sensor error
4 times
Sonda ambiente unidad exterior
Outdoor unit compressor sensor error
6 times
Sonda temperatura compresor
Compressor loter location error
7 times
No se detecta la posicion del rotor del compresor
Outdoor unit IPM error
8 times
Error del modulo IPM
CT error
9 times
Error CT (transformador de corriente)
Active Filter Module (AFM) error
10 times
Error de filtro activo de potencia (AFM)
Outdoor unit fan motor error
11 times
Error ventilador exterior
Outdoor unit 2-way valve sensor error
1 times
Sonda temperatura válvula de 2 vías
Outdoor expansión valve high temperature error
2 times
Sonda temperatura válvula de 3 vías
Capacity error of connecting indoor unit
3 times
Error de capacidad unidades interioes conectadas
Reverse signal error (outdoor unit ---> indoor unit)
4 times
Error comunicación de unidad exterior a interior
Indoor unit room temperature sensor error
5 times
Sonda ambiente unidad interior
Indoor unit heat exchanger señor error
6 times
Sonda tubo unidad interior
Indoor unit fan motor error
7 times
Errror ventilador unidad interior
PARPADEO RAPIDO :
PARPADEO LENTO :
APAGADO :
41
AUTODIAGNOSTICO - TABLA 10
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELO CORRESPONDIENTES: U.I. MULTI INVERTER 4x1 (R407C)
AS*18QMAW - AS*24QMAW
Error display
Error contents / CONTENIDO DE ERRORES OPERATION TIMER SWING
(RED) (GREEN) (ORANGE)
Indoor unit room temperature sensor wire opened
2 times
Sonda ambiente unidad interior abierta
Indoor unit room temperature sensor wire short circuited
2 times
Sonda ambiente unidad interior en corto
Indoor unit piping sensor wire opened
3 times
Sonda tubo unidad interior abierto
Indoor unit piping sensor short circuited
3 times
Sonda tubo unidad interior en corto
Reverse signal error (outdoor unit ---> indoor unit)
5 times
Error de comunicación de unidad exterior a unidad interior
Forward signal error ( indoor unit ---> outdoor unit)
5 times
Error de comunicación de unidad interior a unidad exterior
Indoor unit fan error
6 times
Error ventilador unidad interior
Outdoor unit piping sensor
3 times
Sonda tubo unidad exterior
Outdoor unit outdoor temperature sensor error
4 times
Sonda ambiente unidad exterior
Outdoor unit discharge temperature sensor error
5 times
Sonda tubo de descarga
High pressure error
6 times
Protección alta presión en frío
Outdoor unit compressor temperature sensor error
8 times
Sonda temperatura compresor
Outdoor unit pressure switch error
9 times
Presostato alta activado
IPM error
10 times
Error del modulo IPM
CT error
11 times
Error CT (transformador de corriente)
Active Filter Module (AFM) error
12 times
Error de filtro activo de potencia (AFM)
Compressor rotor position cannot detect
13 times
No se detecta la posicion del rotor del compresor
Outdoor fan motor error
14 times
Error ventilador unidad exterior
Outdoor unit 2 way valve temperature sensor error
2 times
Error de sonda de temperatura de valvula de 2 vias
Outdoor unit 3 way valve temperature sensor error
3 times
Error de sonda de temperatura de valvula de 3 vias
Idoor unit connection capacity error
4 times
Error de potencia de unidad inteior conectada
PARPADEO RAPIDO :
PARPADEO LENTO :
APAGADO :
42
AUTODIAGNOSTICO - TABLA 11
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELO CORRESPONDIENTES: U.E. MULTI INVERTER 4x1 (R407C)
AOH30QMAM4 "Multi controller PCB"
Error display
Error contents
LED1 LED2
Normal Every indoor unit is fine
off on
Todas las unidades interiores estan ok
Indoor unit Serial A abnormal, Out of connection
off 1 time off
Error comunicación de unidad interior A a exterior
Serial A abnormal, Out of connection
off 2 times off
Error comunicación de unidad interior B a exterior
Serial A abnormal, Out of connection
off 3 times off
Error comunicación de unidad interior C a exterior
Serial A abnormal, Out of connection
off 4 times off
Error comunicación de unidad interior D a exterior
All serial (A, B, C, D) abnormal, Out of connection
off 5 times off
Error comunicación de unidad exterior a interior
Serial signal Communication error (Inverter PCB -> Multi controller PCB)
1 time off off
Error comunicación de Inverter PCB -> Multi controller PCB
Inverter PCB Communication error (Multi controller PCB -> Inverter PCB)
2 times off 1 time off
(Outdoor unit) Error comunicación de Multi controller PCB -> Inverter PCB
Discharge temperature thermister abnormal
2 times off 2 times off
Sonda temperatura de descarga
Heat exchanger temperature themister abnormal
2 times off 3 times off
Sonda tubo unidad exterior
Outdoor temperature thermister abnormal
2 times off 4 times off
Sonda ambiente unidad exterior
Pressure switch A abnormal
2 times off 5 times off
Presostato alta activado
2nd time Discharge temperature abnormal (permanent stop)
2 times off 7 times off
2ª vez sonda temperatura de descarga anormal (paro permanente)
Outdoor unit IPM error (permanent stop)
2 times off 8 times off
Error del modulo IPM
2nd time CT abnormal (permanent stop)
2 times off 9 times off
2ª vez error CT (paro permanente)
Active filter abnormal (permanent stop)
2 times off 10 times off
Error de filtro activo de potencia AFM (paro permanente)
Outdoor fan abnormal (permanent stop)
2 times off 11 times off
Error ventilador exterior (paro permanente)
Compressor temperature thermister abnormal
2 times off 13 times off
Sonda temperatura compresor
Faulty compressor start
2 times off 14 times off
Compresor no puede arrancar
Cooling high pressure over protection
2 times off 15 times off
Protección alta presión en frío
2-way valve 2-way valve thermister A abnormal
3 times off 1 time off
Sonda temperatura válvula de 2 vías A
2-way valve thermister B abnormal
3 times off 2 times off
Sonda temperatura válvula de 2 vías B
2-way valve thermister C abnormal
3 times off 3 times off
Sonda temperatura válvula de 2 vías C
2-way valve thermister D abnormal
3 times off 4 times off
Sonda temperatura válvula de 2 vías D
Otros Total Indoor units capacity is over outdoor capacity
4 times off 2 times off
Se excede la capacidad de conexión de las unidades interiores
43
AUTODIAGNOSTICO - TABLA 12
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELO CORRESPONDIENTES: U.I. CONDUCTOS GAMA COMERCIAL
AR*18LUAD - AR*24LUAN - AR*30LUAN - AR*36LUAN - AR*45LUAN
AR*45LUAK - AR*54LUAK
Error code Error contents
44
AUTODIAGNOSTICO - TABLA 13
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELO CORRESPONDIENTES: U.I. CASSETTE GAMA COMERCIAL
AU*24LUAR - AU*30LUAR - AU*36LUAS - AU*45LUAS
Error code Error contents
Communication error (indoor unit <----> remote controller)
00
Error de comunicación entre unidad interior y mando por cable
Reverse signal error (outdoor unit ---> indoor unit)
01
Error de comunicación de unidad exterior a unidad interior
Room temperature sensor open
02
Sonda ambiente unidad interior abierta
Room temperature sensor short-circuited
03
Sonda ambiente unidad interior en corto
Indoor heat exchanger temperature sensor open
04
Sonda tubo unidad interior abierta
Indoor heat exchanger temperature sensor short-circuited
05
Sonda tubo unidad interior en corto
Outdoor heat exchanger temperature sensor
06
Sonda tubo unidad exterior
Power source connection error
08 Error alimentación
Float switch operated
09
Alarma bomba condensados
Outdoor temperature sensor
0A
Sonda ambiente unidad exterior
Discharge pipe temperature sensor
0c
Sonda temperatura de descarga
Model abnormal
11
Modelos incompatibles
Indoor fan abnormal
12
Errror ventilador unidad interior
Forward signal error ( indoor unit ---> outdoor unit)
13
Error de comunicación de unidad interior a unidad exterior
Excessive outdoor pressure (permanent stop)
14
Protección alta presión en frío (paro permanente)
Compressor temperature sensor
15
Sonda temperatura compresor
Pressure switch error
16
Presostato alta activado
IPM error
17
Error del modulo IPM
CT error
18
Error CT (transformador de corriente)
Active Filter Module (AFM) error
19
Error de filtro activo de potencia (AFM)
Compressor does not operate
1A
Compresor no puede arrancar
Outdoor unit fan error
1b Error ventilador exterior
45
AUTODIAGNOSTICO - TABLA 14
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELO CORRESPONDIENTES:
U.I. CASSETTE GAMA COMERCIAL: AU*18LBAB
U.I. SUELO TECHO GAMA COMERCIAL: AB*18LBAJ - AB*24LBAJ
Error display
Error contents / CONTENIDO DE ERRORES OPERATION TIMER SWING
(RED) (GREEN) (ORANGE)
Indoor unit circuit board error (EEPROM)
Error circuito placa unidad interior (EEPROM)
Indoor unit room temperature sensor wire opened
2 times
Sonda ambiente unidad interior abierta
Indoor unit room temperature sensor wire short circuited
2 times
Sonda ambiente unidad interior en corto
Indoor unit piping sensor wire opened
3 times
Sonda tubo unidad interior abierto
Indoor unit piping sensor short circuited
3 times
Sonda tubo unidad interior en corto
Drain pump error
4 times
Alarma bomba condensados
Reverse signal error (outdoor unit ---> indoor unit)
5 times
Error de comunicación de unidad exterior a unidad interior
Forward signal error ( indoor unit ---> outdoor unit)
5 times
Error de comunicación de unidad interior a unidad exterior
Indoor unit fan error
6 times
Error ventilador unidad interior
Outdoor unit piping sensor
3 times
Sonda tubo unidad exterior
Outdoor unit outdoor temperature sensor error
4 times
Sonda ambiente unidad exterior
Outdoor unit discharge temperature sensor error
5 times
Sonda temperatura de descarga
Outdoor unit compressor temperature sensor error
8 times
Sonda temperatura compresor
Outdoor unit pressure switch error
9 times
Presostato alta activado
IPM error
10 times
Error del modulo IPM
CT error
11 times
Error CT (transformador de corriente)
Active Filter Module (AFM) error
12 times
Error de filtro activo de potencia (AFM)
Compressor rotor position cannot detect
13 times
No se detecta la posicion del rotor del compresor
Outdoor fan motor error
14 times
Error ventilador unidad exterior
Outdoor unit 2 way valve temperature sensor error
2 times
Error de sonda de temperatura de valvula de 2 vias
Outdoor unit 3 way valve temperature sensor error
3 times
Error de sonda de temperatura de valvula de 3 vias
Idoor unit connection capacity error
4 times
Error de potencia de unidad inteior conectada
Communication error (inverter - multicontroller)
5 times
Error de comunicación (inverter - multicontroller)
PARPADEO RAPIDO :
PARPADEO LENTO :
APAGADO :
46
AUTODIAGNOSTICO - TABLA 15
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELO CORRESPONDIENTES: U.E. GAMA COMERCIAL
AOH18LMAKL - AOH24LMAKL
Error contents LED (RED)
Serial signal error
1 flash
Error de comunicación (unidad interior <--> unidad exterior)
Discharge pipe thermistor error
2 flash
Sonda temperatura de descarga
Heat exchanger thermistor error
3 flash
Sonda tubo unidad exterior
Outdoor temperature thermistor error
4 flash
Sonda ambiente unidad exterior
2-way valve thermistor A, B error
5 flash
Error sonda valvula 2 vias A, B
3-way valve thermistor A, B error
6 flash
Error sonda valvula 3 vias A, B
Compressor thermistor error
7 flash
Sonda temperatura compresor
Pressure switch error
8 flash
Presostato alta activado
Indoor unit communication error
9 flash
Unidad interior incompatible
IPM error
10 flash
Error del modulo IPM
CT error
11 flash
Error CT (transformador de corriente)
Compressor position detection error
12 flash
No se detecta la posición del rotor del compresor
Compressor starting error
13 flash
Compresor no puede arrancar
Timer error
14 flash
Timer
AUTODIAGNOSTICO - TABLA 16
TABLA DE FUNCIONES DE AUTODIAGNÓSTICO
MODELO CORRESPONDIENTES: U.E. GAMA COMERCIAL
AOH30LMAWL - AOH36LMAWL - AOH45LJBYL
AOH45LJAYL - AOH54LJAYL
Error contents LED
Communication error ((Indoor unit - Outdoor unit))
1 flash
Error de comunicación (unidad interior <--> unidad exterior)
Discharge pipe temperature sensor
2 flash
Sonda temperatura de descarga
Outdoor heat exchanger temperature sensor
3 flash
Sonda tubo unidad exterior
Outdoor temperature sensor
4 flash
Sonda ambiente unidad exterior
Compressor temperature sensor
7 flash
Sonda temperatura compresor
Heat sink temperature sensor
8 flash
Sonda disipador modulo IPM
Pressure switch anormal
9 flash
Presostato alta activado
IPM error
12 flash
Error del modulo IPM
Compressor rotor position cannot detect
13 flash
No se detecta la posición del rotor del compresor
Compressor cannot operate
14 flash
Compresor no puede arrancar
Outdoor fan abnormal (upper fan)
15 flash
Error ventilador exterior (ventilador superior)
Outdoor fan abnormal (lower fan)
16 flash
Error ventilador exterior (ventilador inferior)
Protect operation
5 sec. ON/1 sec. OFF repeated
Operación en modo protección
No error
Off
Ninguna alarma
47
6. RESOLUCION DE AVERIAS
48
Error de comunicación
Posibles causas:
1) El circuito de comunicación de la unidad interior o exterior se ha dañado.
2) Los cables de interconexión entre unidad interior y exterior están cruzados, por
ejemplo se han conectado fase por neutro.
Para descartar si es un problema eléctrico de la uniad exterior (que no tiene nada que ver
realmente con la señal de comunicación), comprobar siempre que haya tensión
entre P y N del filtro activo de potencia o modulo inverter. Esta tensión es
proximadamente de unos 310 V DC con el compresor parado.
Si la máquina se alimenta a través de la unidad interior, conectar la unidad exterior
directamente a la fuente de alimentación y comprobar si llega o no tensión.
49
Ejemplo señal de comunicación entre unidades
INFORMATION 1
Forward Serial signal
Indoor Unit Outdoor Unit
INFORMATION 2
Reverse Serial signal
Example of Serial Signal of ASY24PBA-
ASY24PBA-W/AOY24PMAL
50
310V DC aprox
a) RESISTENCIA PTC 380V DC con el compresor
De 30 a 190V AC aprox
O POSISTOR a frecuencia variable
en funcionamiento.
Módulo Inverter
Potencia (AFM)
Filtro Activo de
Puente Diodos
AC
(IPM)
U
Bobina de
Alimentación V
Eléctrica
Choque Motor
W
51
a) RESISTENCIA PTC 0 V entre P y N cuando alguno de los
O POSISTOR (abierto) componentes electrónicos esta en corto
Potencia (AFM)
Filtro Activo de
Puente Diodos
(IPM)
AC U
Bobina de
Alimentación V
Choque Motor
Eléctrica
W
Que pasa si el relee no cierra? La intensidad pasará por el posistor. Al calentarse abre
y corta la alimentación al puente rectificador de diodos. Dejamos de tener tensión entre P
y N. Obtenemos error de comunicación. Obtenemos error de comunicación de unidad
exterior a interior.
Que pasa si se ha quemado algún componente electrónico de la unidad exterior,
por ejemplo el IPM, y no hay resistencia entre P y N? Cuando lleguan los 230V AC a
la unidad exterior, se crea una intensidad de cortocircuito. Esta intensidad pasará por el
posistor (ya que la máquina todavía no ha dado el Ok y no ha cerrado el relee). Esto
provoca que el posistor abra y corte la alimentación de la máquina. No tenemos tensión
entre P y N. Obtenemos error de comunicación de unidad exterior a interior.
52
Comprobación de la Señal de Comunicación (1/2)
- Funcionamiento normal entre unidad interior y unidad exterior. (En las unidades
alimentadas directamente a la unidad exterior, se puede leer la señal de comunicación sin
necesidad de poner la unidad interior en funcionamiento).
1º) Borne 3 a entrada del diodo, + del tester a salida del diodo y – del tester a la borne N
Tenemos que obtener una tensión de 30V a 50V DC (puede dar puntualmente 0V)
N 3
Diodo
2º) Borne N a entrada del diodo, + del tester a salida del diodo y – del tester a la borne 3
mediciones sobre
bornes unidad exterior
3
N
Diodo
54
IPM error
Puntos a comprobar:
1. Entrada o salida de aire de la bateria exterior está bloqueada.
2. Comprobar el estado del ventilador de la unidad exterior.
3. Revisar el módulo inverter o placa de control si ésta lo incluye.
4. Comprobar la resistencia de las bobinas del compresor y estado de las conexiones.
5. Revisar el estado de la EEV y de los sensores de temperatura
Puntos a comprobar:
1. Comprobar que la válvula de 2 vías o 3 vías se haya quedado abierta.
2. Comprobar la resistencia de las bobinas del compresor y estado de las conexiones.
3. Revisar el estado de la EEV y de los sensores de temperatura.
4. Placa de control defectuosa.
55
Comprobación del modulo inverter IPM (1/2)
5 V DC
TIERRA
5 V DC
Detección de posición
Control IPM
15 V DC
Alimentación del IPM TIERRA
En el caso de las unidades exteriores con una sola placa o con placa de control que
incorpora el módulo inverter, no es posible realizar estas mediciones.
56
Comprobación del modulo inverter IPM (2/2)
P U V W N
En el caso de las unidades exteriores con una sola placa o con placa de control que
incorpora el módulo inverter, para la unidad exterior AOH45LJAYL hemos obtenido los
siguientes valores (desconectado los cables del U-V-W y P-N):
Multimeter Resistencia
- + kΩ
U 370
P V 330
W 373
U 368
V N 325
W 369
N W V U P
57
Comprobación del compresor (1/1)
Resistencia entre 1 y 2 Ω
aproximadamente.
58
Active Filter Module (AFM) error
Puntos a comprobar:
1. Comprobar las conexiones.
2. Comprobar el voltaje de entrada y el voltaje a la salida filtro. El rango de
funconamiento con el compresor en marcha está entre 350 y 425 V DC.
3. Comprobar circuito interno del filtro activo según tabla adjunta.
4. Sustituir la placa de control si los valores anteriores son correctos.
59
Comprobación del ACTIVE FILTER MODULE (AFM) (1/2)
-desconectar todos los cables del modulo y medir los valores ómhnicos según esquema
60
Comprobación del ACTIVE FILTER MODULE (AFM) (2/2)
-
+
L1
P
L2
N
61
Outdoor Fan Error (DC motor)
Puntos a comprobar:
62
CT error
Error de consumo
El compresor y el ventilador exterior se paran cuando la corriente total de la unidad
exteriror detectado por el transforamdor de corriente (Current Transformer) es igual a 0 A
un minuto después de arrancar el compresor.
Puntos a comprobar:
1. Comprobar que el cable que pasa por CT está abierto.
2. Placa de control unidad exterior defectuosa.
63
Comprobación del Puente Rectificador de Diodos (1/2)
El chaflán -
siempre
parte +
64
Comprobación del Puente Rectificador de Diodos (2/2)
Ejemplo de mediciones:
∞ - INFINTO
65
Comprobación EEV (válvula de expansión electrónica ) (1/2)
Color de Resistencia Ω
cables (aprox)
Rojo - Naranja
43 Ω
Rojo - Blanco
Naranja - Blanco 85 Ω
Marrón - Azul
Marrón - Amarillo 43 Ω
Azul - Amarillo 85 Ω
66
Comprobación EEV (válvula de expansión electrónica ) (2/2)
67
7. VALORES DE LAS SONDAS
68
Valores de las sondas máquinas inverter
69
8. COMBINACIONES SERIE F
70
Inverter Multi R410A Connection Table
71
AO*18LMAK2 05/06/15
Cooling capacity for Cooling capacity for
indoor model for Annual energy
AO*18LMAK2 each indoor unit each indoor unit Total cooling capacity (kW) Total Input (kW) EER
each room consumption Class
Rated (kW) Max (kW) (W/W)
(KW/h)
room 1 room 2 total room 1 room 2 room 1 room 2 min rated max min rated max
min 14 kBTU 7 7 14 2,20 2,20 2,50 2,50 2,00 4,40 5,00 0,68 1,41 1,71 705 3,12 B
max 24 kBTU 7 9 16 2,30 2,80 2,48 3,02 2,00 5,10 5,50 0,68 1,70 1,86 850 3,00 C
7 12 19 2,05 3,25 2,28 3,62 2,00 5,30 5,90 0,68 1,73 2,07 865 3,06 B
7 14 21 1,90 3,50 2,25 4,15 2,00 5,40 6,40 0,68 1,73 2,22 865 3,12 B
9 9 18 2,70 2,70 3,00 3,00 2,00 5,40 6,00 0,68 1,73 2,08 865 3,12 B
9 12 21 2,40 3,00 2,84 3,56 2,00 5,40 6,40 0,68 1,72 2,22 860 3,14 B
9 14 23 2,20 3,30 2,60 3,90 2,00 5,50 6,50 0,68 1,73 2,22 865 3,18 B
12 12 24 2,70 2,70 3,20 3,20 2,00 5,40 6,40 0,68 1,70 2,22 850 3,18 B
AO*24LMAM2
Cooling capacity for Cooling capacity for
indoor model for Annual energy
AO*24LMAM2 each indoor unit each indoor unit Total cooling capacity (kW) Total Input (kW) EER
each room consumption Class
Rated (kW) Max (kW) (W/W)
(KW/h)
room 1 room 2 total room 1 room 2 room 1 room 2 min rated max min rated max
min 14 kBTU 7 7 14 2,20 2,20 2,50 2,50 2,00 4,40 5,00 0,68 1,41 1,71 705 3,12 B
max 30 kBTU 7 9 16 2,30 2,80 2,48 3,02 2,00 5,10 5,50 0,68 1,70 1,86 850 3,00 C
7 12 19 2,05 3,25 2,28 3,62 2,00 5,30 5,90 0,68 1,73 2,07 865 3,06 B
7 14 21 1,90 3,50 2,39 4,41 2,00 5,40 6,80 0,68 1,73 2,60 865 3,12 B
7 18 25 1,70 4,00 2,27 5,33 2,00 5,70 7,60 0,68 1,73 2,77 865 3,29 A
9 9 18 2,70 2,70 3,00 3,00 2,00 5,40 6,00 0,68 1,73 2,08 865 3,12 B
9 12 21 2,40 3,00 2,98 3,72 2,00 5,40 6,70 0,68 1,72 2,58 860 3,14 B
9 14 23 2,20 3,30 2,92 4,38 2,00 5,50 7,30 0,68 1,73 2,77 865 3,18 B
9 18 27 2,00 3,80 2,66 5,04 2,50 5,80 7,70 0,80 1,73 2,77 865 3,35 A
12 12 24 2,75 2,75 3,55 3,55 2,00 5,50 7,10 0,68 1,70 2,77 850 3,24 A
12 14 26 2,60 3,00 3,44 3,96 2,00 5,60 7,40 0,68 1,73 2,77 865 3,24 A
12 18 30 2,30 3,50 3,09 4,71 2,50 5,80 7,80 0,80 1,73 2,77 865 3,35 A
14 14 28 2,85 2,85 3,85 3,85 2,50 5,70 7,70 0,80 1,74 2,77 870 3,28 A
72
12 18 30 2,40 4,00 3,38 5,63 2,70 6,40 9,00 0,80 1,64 2,77 820 3,90 A
14 14 28 3,20 3,20 4,40 4,40 2,70 6,40 8,80 0,80 1,75 2,77 875 3,66 A
AO*30LMAW4
Cooling capacity for each indoor unit Cooling capacity for each indoor
indoor model for each room Total cooling capacity (kW) Total Input (kW) Annual energy EER
Rated (kW) unit Max (kW) Class
consumption,(KW/h) (W/W)
AO*30LMAW4 room 1 room 2 room 3 room 4 total room 1 room 2 room 3 room 4 room 1 room 2 room 3 room 4 min rated max min rated max
min 27 kBTU 14 7 7 - 28 3,27 1,96 1,96 - 4,05 2,43 2,43 - 1,60 7,2 8,9 0,68 2,22 3,43 1110 3,24 A
max 49 kBTU 18 7 7 - 32 4,08 1,81 1,81 - 5,29 2,35 2,35 - 2,80 7,7 10,0 0,98 2,22 3,55 1110 3,47 A
22 7 7 - 36 4,49 1,66 1,66 - 5,81 2,15 2,15 - 2,80 7,8 10,1 0,98 2,17 3,58 1085 3,59 A
24 7 7 - 38 4,57 1,61 1,61 - 5,92 2,09 2,09 - 2,80 7,8 10,1 0,98 2,19 3,53 1095 3,56 A
12 9 7 - 28 2,78 2,34 2,08 - 3,43 2,90 2,57 - 1,60 7,2 8,9 0,68 2,22 3,41 1110 3,24 A
14 9 7 - 30 3,16 2,14 1,90 - 4,00 2,70 2,40 - 2,80 7,2 9,1 0,98 2,22 3,56 1110 3,24 A
18 9 7 - 34 3,96 1,98 1,76 - 5,09 2,55 2,26 - 2,80 7,7 9,9 0,98 2,22 3,56 1110 3,47 A
22 9 7 - 38 4,37 1,82 1,61 - 5,66 2,35 2,09 - 2,80 7,8 10,1 0,98 2,22 3,58 1110 3,51 A
24 9 7 - 40 4,46 1,77 1,57 - 5,77 2,29 2,04 - 2,80 7,8 10,1 0,98 2,19 3,53 1095 3,56 A
12 12 7 - 31 2,62 2,62 1,96 - 3,31 3,31 2,48 - 1,60 7,2 9,1 0,68 2,22 3,54 1110 3,24 A
14 12 7 - 33 3,04 2,43 1,83 - 3,83 3,07 2,30 - 2,80 7,3 9,2 0,98 2,22 3,56 1110 3,29 A
18 12 7 - 37 3,78 2,24 1,68 - 4,86 2,88 2,16 - 2,80 7,7 9,9 0,98 2,22 3,56 1110 3,47 A
22 12 7 - 41 4,19 2,06 1,55 - 5,43 2,67 2,00 - 2,80 7,8 10,1 0,98 2,22 3,58 1110 3,51 A
24 12 7 - 43 4,28 2,01 1,51 - 5,54 2,61 1,95 - 2,80 7,8 10,1 0,98 2,19 3,56 1095 3,56 A
14 14 7 - 35 2,81 2,81 1,68 - 3,58 3,58 2,15 - 2,80 7,3 9,3 0,98 2,22 3,58 1110 3,29 A
18 14 7 - 39 3,52 2,61 1,57 - 4,58 3,39 2,03 - 3,50 7,7 10,0 1,17 2,22 3,58 1110 3,47 A
22 14 7 - 43 3,93 2,42 1,45 - 5,09 3,13 1,88 - 3,50 7,8 10,1 1,17 2,22 3,58 1110 3,51 A
24 14 7 - 45 4,07 2,39 1,44 - 5,20 3,06 1,84 - 3,50 7,9 10,1 1,17 2,20 3,58 1100 3,59 A
9 9 9 - 27 2,40 2,40 2,40 - 2,97 2,97 2,97 - 2,80 7,2 8,9 0,98 2,22 3,42 1110 3,24 A
12 9 9 - 30 2,68 2,26 2,26 - 3,39 2,86 2,86 - 2,80 7,2 9,1 0,98 2,22 3,54 1110 3,24 A
14 9 9 - 32 3,11 2,10 2,10 - 3,91 2,64 2,64 - 2,80 7,3 9,2 0,98 2,22 3,57 1110 3,29 A
18 9 9 - 36 3,85 1,93 1,93 - 4,95 2,48 2,48 - 2,80 7,7 9,9 0,98 2,22 3,56 1110 3,47 A
22 9 9 - 40 4,26 1,77 1,77 - 5,52 2,29 2,29 - 2,80 7,8 10,1 0,98 2,22 3,58 1110 3,51 A
24 9 9 - 42 4,35 1,73 1,73 - 5,63 2,24 2,24 - 2,80 7,8 10,1 1,17 2,20 3,54 1100 3,55 A
12 12 9 - 33 2,53 2,53 2,14 - 3,20 3,20 2,70 - 2,80 7,2 9,1 0,98 2,22 3,54 1110 3,24 A
14 12 9 - 35 2,95 2,36 1,99 - 3,72 2,97 2,51 - 2,80 7,3 9,2 0,98 2,22 3,57 1110 3,29 A
18 12 9 - 39 3,68 2,18 1,84 - 4,73 2,80 2,37 - 2,80 7,7 9,9 0,98 2,22 3,56 1110 3,47 A
22 12 9 - 43 4,09 2,01 1,70 - 5,29 2,61 2,20 - 2,80 7,8 10,1 0,98 2,22 3,58 1110 3,51 A
24 12 9 - 45 4,18 1,97 1,66 - 5,41 2,54 2,15 - 2,80 7,8 10,1 0,98 2,19 3,56 1095 3,56 A
14 14 9 - 37 2,73 2,73 1,84 - 3,48 3,48 2,35 - 3,50 7,3 9,3 1,17 2,22 3,58 1110 3,29 A
18 14 9 - 41 3,48 2,58 1,74 - 4,46 3,31 2,23 - 3,50 7,8 10,0 1,17 2,22 3,58 1110 3,51 A
22 14 9 - 45 3,84 2,36 1,60 - 4,97 3,06 2,07 - 3,50 7,8 10,1 1,17 2,22 3,58 1110 3,51 A
24 14 9 - 47 3,98 2,34 1,58 - 5,09 2,99 2,02 - 3,50 7,9 10,1 1,27 2,22 3,56 1110 3,56 A
12 12 12 - 36 2,43 2,43 2,43 - 3,07 3,07 3,07 - 2,80 7,3 9,2 0,98 2,22 3,55 1110 3,29 A
14 12 12 - 38 2,85 2,28 2,28 - 3,58 2,86 2,86 - 2,80 7,4 9,3 0,98 2,22 3,58 1110 3,33 A
18 12 12 - 42 3,57 2,12 2,12 - 4,58 2,71 2,71 - 3,50 7,8 10,0 1,17 2,22 3,57 1110 3,51 A
22 12 12 - 46 3,98 1,96 1,96 - 5,09 2,51 2,51 - 3,50 7,9 10,1 1,17 2,22 3,58 1110 3,56 A
24 12 12 - 48 4,07 1,92 1,92 - 5,20 2,45 2,45 - 3,50 7,9 10,1 1,17 2,20 3,54 1100 3,59 A
14 14 12 - 40 2,64 2,64 2,11 - 3,36 3,36 2,69 - 3,50 7,4 9,4 1,17 2,22 3,58 1110 3,33 A
18 14 12 - 44 3,34 2,48 1,98 - 4,33 3,21 2,57 - 3,50 7,8 10,1 1,17 2,22 3,58 1110 3,51 A
22 14 12 - 48 3,75 2,31 1,85 - 4,79 2,95 2,36 - 3,50 7,9 10,1 1,17 2,22 3,58 1110 3,56 A
18 18 7 - 43 3,19 3,19 1,42 - 4,13 4,13 1,84 - 3,50 7,8 10,1 1,17 2,22 3,58 1110 3,51 A
22 18 7 - 47 3,59 2,98 1,33 - 4,59 3,81 1,70 - 3,50 7,9 10,1 1,17 2,22 3,58 1110 3,56 A
24 18 7 - 49 3,68 2,92 1,30 - 4,70 3,74 1,66 - 4,70 7,9 10,1 1,27 2,22 3,58 1110 3,56 A
18 18 9 - 45 3,12 3,12 1,56 - 4,04 4,04 2,02 - 4,70 7,8 10,1 1,27 2,22 3,58 1110 3,51 A
22 18 9 - 49 3,52 2,92 1,46 - 4,50 3,74 1,87 - 4,70 7,9 10,1 1,27 2,22 3,58 1110 3,56 A
18 18 12 - 48 3,05 3,05 1,81 - 3,90 3,90 2,31 - 4,70 7,9 10,1 1,27 2,22 3,58 1110 3,56 A
73
Cooling capacity for each indoor unit Cooling capacity for each indoor
indoor model for each room Total cooling capacity (kW) Total Input (kW) Annual energy EER
Rated (kW) unit Max (kW) Class
consumption,(KW/h) (W/W)
AO*30LMAW4 room 1 room 2 room 3 room 4 total room 1 room 2 room 3 room 4 room 1 room 2 room 3 room 4 min rated max min rated max
min 27 kBTU 7 7 7 7 28 1,90 1,90 1,90 1,90 2,40 2,40 2,40 2,40 1,60 7,6 9,6 0,68 2,20 3,41 1100 3,45 A
max 49 kBTU 9 7 7 7 30 2,07 1,84 1,84 1,84 2,67 2,38 2,38 2,38 1,60 7,6 9,8 0,68 2,22 3,54 1110 3,42 A
12 7 7 7 33 2,37 1,78 1,78 1,78 3,05 2,28 2,28 2,28 1,60 7,7 9,9 0,68 2,22 3,54 1110 3,47 A
14 7 7 7 35 2,75 1,65 1,65 1,65 3,54 2,12 2,12 2,12 2,80 7,7 9,9 0,98 2,22 3,56 1110 3,47 A
18 7 7 7 39 3,43 1,52 1,52 1,52 4,33 1,92 1,92 1,92 2,80 8,0 10,1 0,98 2,20 3,55 1100 3,64 A
22 7 7 7 43 3,80 1,40 1,40 1,40 4,79 1,77 1,77 1,77 2,80 8,0 10,1 0,98 2,22 3,58 1110 3,60 A
9 9 7 7 32 2,04 2,04 1,81 1,81 2,57 2,57 2,28 2,28 2,80 7,7 9,7 0,98 2,22 3,42 1110 3,47 A
12 9 7 7 35 2,30 1,94 1,73 1,73 2,96 2,50 2,22 2,22 2,80 7,7 9,9 0,98 2,22 3,55 1110 3,47 A
14 9 7 7 37 2,68 1,81 1,61 1,61 3,48 2,35 2,09 2,09 2,80 7,7 10,0 0,98 2,22 3,57 1110 3,47 A
18 9 7 7 41 3,35 1,67 1,49 1,49 4,23 2,11 1,88 1,88 3,50 8,0 10,1 1,17 2,20 3,55 1100 3,64 A
22 9 7 7 45 3,71 1,54 1,37 1,37 4,69 1,95 1,73 1,73 3,50 8,0 10,1 1,17 2,22 3,58 1110 3,60 A
12 12 7 7 38 2,20 2,20 1,65 1,65 2,86 2,86 2,14 2,14 2,80 7,7 10,0 0,98 2,22 3,55 1110 3,47 A
14 12 7 7 40 2,60 2,08 1,56 1,56 3,33 2,67 2,00 2,00 2,80 7,8 10,0 0,98 2,22 3,57 1110 3,51 A
18 12 7 7 44 3,22 1,91 1,43 1,43 4,07 2,41 1,81 1,81 3,50 8,0 10,1 1,17 2,20 3,56 1100 3,64 A
22 12 7 7 48 3,59 1,77 1,32 1,32 4,53 2,23 1,67 1,67 3,50 8,0 10,1 1,17 2,22 3,58 1110 3,60 A
14 14 7 7 42 2,50 2,50 1,50 1,50 3,16 3,16 1,89 1,89 3,50 8,0 10,1 1,17 2,22 3,58 1110 3,60 A
18 14 7 7 46 3,04 2,25 1,35 1,35 3,84 2,85 1,71 1,71 3,50 8,0 10,1 1,17 2,22 3,58 1110 3,60 A
9 9 9 7 34 1,98 1,98 1,98 1,76 2,55 2,55 2,55 2,26 2,80 7,7 9,9 0,98 2,22 3,56 1110 3,47 A
12 9 9 7 37 2,24 1,89 1,89 1,68 2,91 2,45 2,45 2,18 2,80 7,7 10,0 0,98 2,22 3,56 1110 3,47 A
14 9 9 7 39 2,64 1,78 1,78 1,59 3,42 2,31 2,31 2,05 3,50 7,8 10,1 1,17 2,22 3,58 1110 3,51 A
18 9 9 7 43 3,27 1,64 1,64 1,45 4,13 2,07 2,07 1,84 3,50 8,0 10,1 1,17 2,22 3,56 1110 3,60 A
22 9 9 7 47 3,64 1,51 1,51 1,34 4,59 1,91 1,91 1,70 3,50 8,0 10,1 1,17 2,22 3,58 1110 3,60 A
12 12 9 7 40 2,17 2,17 1,83 1,63 2,78 2,78 2,35 2,09 2,80 7,8 10,0 0,98 2,22 3,56 1110 3,51 A
14 12 9 7 42 2,54 2,03 1,71 1,52 3,28 2,63 2,22 1,97 3,50 7,8 10,1 1,17 2,22 3,58 1110 3,51 A
18 12 9 7 46 3,15 1,87 1,58 1,40 3,98 2,36 1,99 1,77 3,50 8,0 10,1 1,17 2,22 3,56 1110 3,60 A
14 14 9 7 44 2,41 2,41 1,63 1,45 3,08 3,08 2,08 1,85 3,50 7,9 10,1 1,17 2,22 3,58 1110 3,56 A
18 14 9 7 48 2,98 2,21 1,49 1,32 3,76 2,79 1,88 1,67 4,70 8,0 10,1 1,27 2,22 3,57 1110 3,60 A
12 12 12 7 43 2,08 2,08 2,08 1,56 2,69 2,69 2,69 2,02 2,80 7,8 10,1 0,98 2,22 3,56 1110 3,51 A
14 12 12 7 45 2,47 1,98 1,98 1,48 3,16 2,53 2,53 1,89 3,50 7,9 10,1 1,17 2,22 3,58 1110 3,56 A
18 12 12 7 49 3,04 1,80 1,80 1,35 3,84 2,28 2,28 1,71 3,50 8,0 10,1 1,17 2,22 3,56 1110 3,60 A
14 14 12 7 47 2,32 2,32 1,86 1,39 2,97 2,97 2,38 1,78 3,50 7,9 10,1 1,17 2,22 3,58 1110 3,56 A
9 9 9 9 36 1,93 1,93 1,93 1,93 2,50 2,50 2,50 2,50 3,50 7,7 10,0 1,17 2,22 3,56 1110 3,47 A
12 9 9 9 39 2,21 1,86 1,86 1,86 2,83 2,39 2,39 2,39 3,50 7,8 10,0 1,17 2,22 3,57 1110 3,51 A
14 9 9 9 41 2,58 1,74 1,74 1,74 3,34 2,25 2,25 2,25 3,50 7,8 10,1 1,17 2,22 3,58 1110 3,51 A
18 9 9 9 45 3,20 1,60 1,60 1,60 4,04 2,02 2,02 2,02 4,70 8,0 10,1 1,27 2,22 3,58 1110 3,60 A
22 9 9 9 49 3,56 1,48 1,48 1,48 4,50 1,87 1,87 1,87 4,70 8,0 10,1 1,27 2,22 3,58 1110 3,60 A
12 12 9 9 42 2,12 2,12 1,78 1,78 2,74 2,74 2,31 2,31 3,50 7,8 10,1 1,17 2,22 3,58 1110 3,51 A
14 12 9 9 44 2,48 1,98 1,67 1,67 3,21 2,57 2,16 2,16 3,50 7,8 10,1 1,17 2,22 3,58 1110 3,51 A
18 12 9 9 48 3,09 1,83 1,54 1,54 3,90 2,31 1,95 1,95 4,70 8,0 10,1 1,27 2,22 3,58 1110 3,60 A
14 14 9 9 46 2,36 2,36 1,59 1,59 3,01 3,01 2,04 2,04 4,70 7,9 10,1 1,27 2,22 3,58 1110 3,56 A
12 12 12 9 45 2,03 2,03 2,03 1,71 2,63 2,63 2,63 2,22 3,50 7,8 10,1 1,17 2,22 3,58 1110 3,51 A
14 12 12 9 47 2,41 1,93 1,93 1,63 3,08 2,47 2,47 2,08 3,50 7,9 10,1 1,17 2,22 3,58 1110 3,56 A
14 14 12 9 49 2,27 2,27 1,82 1,53 2,91 2,91 2,33 1,96 4,70 7,9 10,1 1,27 2,22 3,58 1110 3,56 A
12 12 12 12 48 1,98 1,98 1,98 1,98 2,53 2,53 2,53 2,53 3,50 7,9 10,1 1,17 2,22 3,58 1110 3,56 A
74
Heating capacity for each indoor unit Heating capacity for each indoor
indoor model for each room Total heating capacity (kW) Total Input (kW) Annual energy COP
Rated (kW) unit Max (kW) Class
consumption,(KW/h) (W/W)
AO*30LMAW4 room 1 room 2 room 3 room 4 total room 1 room 2 room 3 room 4 room 1 room 2 room 3 room 4 min rated max min rated max
min 27 kBTU 14 7 7 - 28 4,15 2,42 2,42 - 4,66 2,72 2,72 - 1,80 9,0 10,1 0,58 2,66 3,53 1330 3,38 C
max 49 kBTU 18 7 7 - 32 4,86 2,27 2,27 - 5,79 2,70 2,70 - 3,30 9,4 11,2 0,87 2,46 3,52 1230 3,82 A
22 7 7 - 36 5,28 2,11 2,11 - 6,44 2,58 2,58 - 3,30 9,5 11,6 0,87 2,43 3,52 1215 3,91 A
24 7 7 - 38 5,44 2,03 2,03 - 6,58 2,46 2,46 - 3,30 9,5 11,5 0,87 2,47 3,52 1235 3,85 A
12 9 7 - 28 3,56 2,94 2,49 - 3,96 3,27 2,77 - 1,80 9,0 10,0 0,58 2,69 3,51 1345 3,34 C
14 9 7 - 30 4,00 2,75 2,33 - 4,49 3,09 2,62 - 3,30 9,1 10,2 0,87 2,64 3,50 1320 3,44 B
18 9 7 - 34 4,66 2,56 2,17 - 5,60 3,08 2,61 - 3,30 9,4 11,3 0,87 2,45 3,50 1225 3,83 A
22 9 7 - 38 5,13 2,42 2,05 - 6,25 2,95 2,50 - 3,30 9,6 11,7 0,87 2,41 3,51 1205 3,98 A
24 9 7 - 40 5,29 2,33 1,98 - 6,34 2,79 2,37 - 3,30 9,6 11,5 0,87 2,46 3,51 1230 3,90 A
12 12 7 - 31 3,33 3,33 2,33 - 3,74 3,74 2,62 - 1,80 9,0 10,1 0,58 2,66 3,48 1330 3,38 C
14 12 7 - 33 3,80 3,17 2,22 - 4,26 3,55 2,49 - 3,30 9,2 10,3 0,87 2,62 3,48 1310 3,51 B
18 12 7 - 37 4,45 2,97 2,08 - 5,34 3,56 2,49 - 3,30 9,5 11,4 0,87 2,44 3,47 1220 3,89 A
22 12 7 - 41 4,87 2,78 1,95 - 5,93 3,39 2,37 - 3,30 9,6 11,7 0,87 2,40 3,49 1200 4,00 A
24 12 7 - 43 5,03 2,69 1,88 - 6,14 3,27 2,29 - 3,30 9,6 11,7 0,87 2,45 3,56 1225 3,92 A
14 14 7 - 35 3,60 3,60 2,10 - 4,10 4,10 2,39 - 3,30 9,3 10,6 0,87 2,59 3,48 1295 3,59 B
18 14 7 - 39 4,19 3,35 1,96 - 5,07 4,06 2,37 - 3,70 9,5 11,5 0,97 2,42 3,52 1210 3,93 A
22 14 7 - 43 4,60 3,16 1,84 - 5,66 3,88 2,26 - 3,70 9,6 11,8 0,97 2,40 3,52 1200 4,00 A
24 14 7 - 45 4,77 3,05 1,78 - 5,81 3,72 2,17 - 3,30 9,6 11,7 0,87 2,45 3,56 1225 3,92 A
9 9 9 - 27 3,00 3,00 3,00 - 3,33 3,33 3,33 - 3,30 9,0 10,0 0,87 2,69 3,51 1345 3,35 C
12 9 9 - 30 3,39 2,80 2,80 - 3,81 3,14 3,14 - 3,30 9,0 10,1 0,87 2,67 3,48 1335 3,37 C
14 9 9 - 32 3,87 2,66 2,66 - 4,34 2,98 2,98 - 3,30 9,2 10,3 0,87 2,63 3,48 1315 3,49 B
18 9 9 - 36 4,52 2,49 2,49 - 5,43 2,99 2,99 - 3,70 9,5 11,4 0,97 2,44 3,48 1220 3,89 A
22 9 9 - 40 4,94 2,33 2,33 - 6,02 2,84 2,84 - 3,70 9,6 11,7 0,97 2,41 3,50 1205 3,98 A
24 9 9 - 42 5,11 2,25 2,25 - 6,22 2,74 2,74 - 3,70 9,6 11,7 0,97 2,45 3,57 1225 3,92 A
12 12 9 - 33 3,22 3,22 2,65 - 3,65 3,65 3,01 - 3,30 9,1 10,3 0,87 2,65 3,52 1325 3,43 B
14 12 9 - 35 3,69 3,07 2,53 - 4,17 3,47 2,86 - 3,30 9,3 10,5 0,87 2,61 3,52 1305 3,56 B
18 12 9 - 39 4,29 2,86 2,36 - 5,14 3,43 2,83 - 3,70 9,5 11,4 0,97 2,43 3,47 1215 3,91 A
22 12 9 - 43 4,70 2,69 2,22 - 5,73 3,27 2,70 - 3,70 9,6 11,7 0,97 2,40 3,48 1200 4,00 A
24 12 9 - 45 4,86 2,59 2,14 - 5,98 3,19 2,63 - 3,70 9,6 11,8 0,97 2,44 3,55 1220 3,93 A
14 14 9 - 37 3,46 3,46 2,38 - 3,98 3,98 2,74 - 3,70 9,3 10,7 0,97 2,58 3,46 1290 3,60 B
18 14 9 - 41 4,04 3,23 2,22 - 4,94 3,95 2,71 - 3,70 9,5 11,6 0,97 2,41 3,51 1205 3,94 A
22 14 9 - 45 4,45 3,05 2,10 - 5,52 3,78 2,60 - 3,70 9,6 11,9 0,97 2,40 3,51 1200 4,00 A
24 14 9 - 47 4,62 2,95 2,03 - 5,72 3,66 2,52 - 4,30 9,6 11,9 1,12 2,42 3,57 1210 3,97 A
12 12 12 - 36 3,07 3,07 3,07 - 3,43 3,43 3,43 - 3,30 9,2 10,3 0,87 2,63 3,49 1315 3,50 B
14 12 12 - 38 3,49 2,91 2,91 - 3,98 3,31 3,31 - 3,30 9,3 10,6 0,87 2,59 3,49 1295 3,59 B
18 12 12 - 42 4,07 2,71 2,71 - 4,97 3,31 3,31 - 3,70 9,5 11,6 0,97 2,42 3,52 1210 3,93 A
22 12 12 - 46 4,48 2,56 2,56 - 5,55 3,17 3,17 - 3,70 9,6 11,9 0,97 2,40 3,52 1200 4,00 A
24 12 12 - 48 4,65 2,48 2,48 - 5,71 3,05 3,05 - 3,70 9,6 11,8 0,97 2,43 3,54 1215 3,95 A
14 14 12 - 40 3,32 3,32 2,76 - 3,81 3,81 3,18 - 3,70 9,4 10,8 0,97 2,40 3,50 1200 3,92 A
18 14 12 - 44 3,85 3,08 2,57 - 4,70 3,76 3,14 - 3,70 9,5 11,6 0,97 2,40 3,49 1200 3,96 A
22 14 12 - 48 4,25 2,92 2,43 - 5,27 3,62 3,01 - 3,70 9,6 11,9 0,97 2,40 3,49 1200 4,00 A
18 18 7 - 43 3,89 3,89 1,82 - 4,86 4,86 2,27 - 3,70 9,6 12,0 0,97 2,40 3,52 1200 4,00 A
22 18 7 - 47 4,25 3,65 1,70 - 5,32 4,56 2,13 - 3,70 9,6 12,0 0,97 2,40 3,52 1200 4,00 A
24 18 7 - 49 4,42 3,53 1,65 - 5,52 4,42 2,06 - 4,30 9,6 12,0 1,12 2,40 3,52 1200 4,00 A
18 18 9 - 45 3,76 3,76 2,07 - 4,71 4,71 2,59 - 4,30 9,6 12,0 1,12 2,40 3,52 1200 4,00 A
22 18 9 - 49 4,12 3,53 1,94 - 5,15 4,42 2,43 - 4,30 9,6 12,0 1,12 2,40 3,52 1200 4,00 A
18 18 12 - 48 3,60 3,60 2,40 - 4,50 4,50 3,00 - 4,30 9,6 12,0 1,12 2,40 3,52 1200 4,00 A
75
Heating capacity for each indoor unit Heating capacity for each indoor
indoor model for each room Total heating capacity (kW) Total Input (kW) Annual energy COP
Rated (kW) unit Max (kW) Class
consumption,(KW/h) (W/W)
AO*30LMAW4 room 1 room 2 room 3 room 4 total room 1 room 2 room 3 room 4 room 1 room 2 room 3 room 4 min rated max min rated max
min 27 kBTU 7 7 7 7 28 2,35 2,35 2,35 2,35 2,70 2,70 2,70 2,70 1,80 9,4 10,8 0,58 2,58 3,47 1290 3,64 A
max 49 kBTU 9 7 7 7 30 2,68 2,27 2,27 2,27 3,07 2,61 2,61 2,61 1,80 9,5 10,9 0,58 2,57 3,51 1285 3,69 A
12 7 7 7 33 3,06 2,14 2,14 2,14 3,58 2,51 2,51 2,51 1,80 9,5 11,1 0,58 2,56 3,55 1280 3,70 A
14 7 7 7 35 3,49 2,04 2,04 2,04 4,11 2,40 2,40 2,40 3,30 9,6 11,3 0,87 2,53 3,56 1265 3,80 A
18 7 7 7 39 4,00 1,87 1,87 1,87 5,00 2,33 2,33 2,33 3,30 9,6 12,0 0,87 2,40 3,56 1200 4,00 A
22 7 7 7 43 4,37 1,75 1,75 1,75 5,45 2,18 2,18 2,18 3,30 9,6 12,0 0,87 2,40 3,56 1200 4,00 A
9 9 7 7 32 2,57 2,57 2,18 2,18 2,95 2,95 2,50 2,50 3,30 9,5 10,9 0,87 2,56 3,44 1280 3,71 A
12 9 7 7 35 2,95 2,43 2,06 2,06 3,44 2,84 2,41 2,41 3,30 9,5 11,1 0,87 2,55 3,54 1275 3,73 A
14 9 7 7 37 3,36 2,31 1,96 1,96 3,99 2,75 2,33 2,33 3,30 9,6 11,4 0,87 2,53 3,54 1265 3,79 A
18 9 7 7 41 3,87 2,13 1,80 1,80 4,83 2,66 2,26 2,26 3,70 9,6 12,0 0,97 2,40 3,55 1200 4,00 A
22 9 7 7 45 4,23 1,99 1,69 1,69 5,28 2,49 2,11 2,11 3,70 9,6 12,0 0,97 2,40 3,55 1200 4,00 A
12 12 7 7 38 2,82 2,82 1,98 1,98 3,32 3,32 2,33 2,33 3,30 9,6 11,3 0,87 2,54 3,57 1270 3,78 A
14 12 7 7 40 3,20 2,67 1,87 1,87 3,83 3,19 2,24 2,24 3,30 9,6 11,5 0,87 2,51 3,58 1255 3,83 A
18 12 7 7 44 3,69 2,46 1,72 1,72 4,62 3,08 2,15 2,15 3,70 9,6 12,0 0,97 2,40 3,58 1200 4,00 A
22 12 7 7 48 4,05 2,31 1,62 1,62 5,06 2,89 2,02 2,02 3,70 9,6 12,0 0,97 2,40 3,58 1200 4,00 A
14 14 7 7 42 3,03 3,03 1,77 1,77 3,73 3,73 2,17 2,17 3,70 9,6 11,8 0,97 2,49 3,58 1245 3,86 A
18 14 7 7 46 3,51 2,81 1,64 1,64 4,39 3,51 2,05 2,05 3,70 9,6 12,0 0,97 2,40 3,56 1200 4,00 A
9 9 9 7 34 2,47 2,47 2,47 2,09 2,91 2,91 2,91 2,47 3,30 9,5 11,2 0,87 2,55 3,54 1275 3,73 A
12 9 9 7 37 2,87 2,36 2,36 2,01 3,37 2,78 2,78 2,36 3,30 9,6 11,3 0,87 2,54 3,58 1270 3,78 A
14 9 9 7 39 3,25 2,23 2,23 1,89 3,89 2,67 2,67 2,27 3,70 9,6 11,5 0,97 2,52 3,58 1260 3,81 A
18 9 9 7 43 3,74 2,06 2,06 1,75 4,68 2,57 2,57 2,18 3,70 9,6 12,0 0,97 2,40 3,58 1200 4,00 A
22 9 9 7 47 4,10 1,93 1,93 1,64 5,12 2,41 2,41 2,05 3,70 9,6 12,0 0,97 2,40 3,58 1200 4,00 A
12 12 9 7 40 2,72 2,72 2,25 1,91 3,23 3,23 2,67 2,26 3,30 9,6 11,4 0,87 2,53 3,58 1265 3,79 A
14 12 9 7 42 3,09 2,58 2,13 1,80 3,74 3,11 2,57 2,18 3,70 9,6 11,6 0,97 2,50 3,58 1250 3,84 A
18 12 9 7 46 3,58 2,39 1,97 1,67 4,47 2,98 2,46 2,09 3,70 9,6 12,0 0,97 2,40 3,58 1200 4,00 A
14 14 9 7 44 2,94 2,94 2,02 1,71 3,61 3,61 2,48 2,10 3,70 9,6 11,8 0,97 2,48 3,58 1240 3,88 A
18 14 9 7 48 3,41 2,73 1,87 1,59 4,26 3,41 2,34 1,99 4,30 9,6 12,0 1,12 2,40 3,58 1200 4,00 A
12 12 12 7 43 2,59 2,59 2,59 1,81 3,11 3,11 3,11 2,18 3,30 9,6 11,5 0,87 2,52 3,58 1260 3,81 A
14 12 12 7 45 2,95 2,46 2,46 1,72 3,60 3,00 3,00 2,10 3,70 9,6 11,7 0,97 2,49 3,58 1245 3,85 A
18 12 12 7 49 3,43 2,29 2,29 1,60 4,29 2,86 2,86 2,00 3,70 9,6 12,0 0,97 2,40 3,56 1200 4,00 A
14 14 12 7 47 2,81 2,81 2,34 1,64 3,48 3,48 2,90 2,03 3,70 9,6 11,9 0,97 2,47 3,58 1235 3,89 A
9 9 9 9 36 2,40 2,40 2,40 2,40 2,83 2,83 2,83 2,83 3,70 9,6 11,3 0,97 2,55 3,58 1275 3,76 A
12 9 9 9 39 2,76 2,28 2,28 2,28 3,28 2,71 2,71 2,71 3,70 9,6 11,4 0,97 2,53 3,58 1265 3,79 A
14 9 9 9 41 3,14 2,16 2,16 2,16 3,79 2,60 2,60 2,60 3,70 9,6 11,6 0,97 2,51 3,58 1255 3,83 A
18 9 9 9 45 3,62 1,99 1,99 1,99 4,53 2,49 2,49 2,49 4,30 9,6 12,0 1,12 2,40 3,58 1200 4,00 A
22 9 9 9 49 3,97 1,87 1,87 1,87 4,97 2,34 2,34 2,34 4,30 9,6 12,0 1,12 2,40 3,58 1200 4,00 A
12 12 9 9 42 2,63 2,63 2,17 2,17 3,15 3,15 2,60 2,60 3,70 9,6 11,5 0,97 2,52 3,58 1260 3,81 A
14 12 9 9 44 2,99 2,49 2,06 2,06 3,65 3,04 2,51 2,51 3,70 9,6 11,7 0,97 2,50 3,58 1250 3,84 A
18 12 9 9 48 3,47 2,31 1,91 1,91 4,34 2,89 2,39 2,39 4,30 9,6 12,0 1,12 2,40 3,58 1200 4,00 A
14 14 9 9 46 2,84 2,84 1,96 1,96 3,53 3,53 2,42 2,42 4,30 9,6 11,9 1,12 2,48 3,58 1240 3,87 A
12 12 12 9 45 2,51 2,51 2,51 2,07 3,03 3,03 3,03 2,50 3,70 9,6 11,6 0,97 2,51 3,58 1255 3,82 A
14 12 12 9 47 2,87 2,39 2,39 1,97 3,52 2,93 2,93 2,42 3,70 9,6 11,8 0,97 2,49 3,58 1245 3,86 A
14 14 12 9 49 2,73 2,73 2,27 1,87 3,38 3,38 2,82 2,32 4,30 9,6 11,9 1,12 2,46 3,58 1230 3,90 A
12 12 12 12 48 2,40 2,40 2,40 2,40 2,90 2,90 2,90 2,90 3,70 9,6 11,6 0,97 2,50 3,58 1250 3,84 A
76
9. DISTANCIAS MINIMAS
77
Tabla 1
Especificaciones Distancia Mínima de tubería (R410A)
7, 9, 12,
14, 17, 18, Debe ser mínimo 5 m
Otros modelos 24, 25 (no se especifica en el Manual Instalación)
(Single Split)
30, 36, 45, Debe ser mínimo 5 m
54, 60
Nota 1. :
Cuando la distancia es inferior a 5 m,
dependiendo de las condiciones de la instalación, se puede producir
un aumento del nivel sonoro o de ruido anormal debido a la transmisión de
ruido de la unidad exterior a la unidad inteior.
** :
En el manual de instalación de los modelos Inverter AS, AW24 - 30 se indica
una distancia mínima de 5 m, pero se modificará a sin límite mínimo.
78
10. LISTA PCB EXTERIORES
79
LISTADO PLACAS Y COMPRESOR UNIDADES EXTERIORES INVERTER
EZ-002LHUE-C
9AGF00174 (PUENTE
AO*9LSACW / RO-9LA / HOW-9LA DE DIODOS EZ-
002GHUE-DB
9AGF00175) EZ-002GHUE-TR ROTATIVO
9AGF00624
EZ-002GHUE-C 9AGF01138 9AGF00619
9AGF00755 (PUENTE
AO*12LSACW / RO-12LA / HOW-12LA DE DIODOS EZ- AC
002GHUE-DB
9AGF00175)
SPLIT PARED SOBRE PCB
INVERTER CONTROL KO4DT-0400HUE-C1
AO*9LFBC / RO-9LB / HOW-9LB SOBRE PCB
9AGF01070
CONTROL SOBRE PCB ROTATIVO
(SUSTITUIDO POR CONTROL 9AGF01068
KO4DT-0401HUE-C1
AO*12LFBC / RO-12LB / HOW-12LB PFC)
9AGF01061
KO4AJ-0400HUE-C1
AO*14LFBC / RO-14LB / HOW-14LB
9AGF01120
K02DS-0400HUE-TRO ROTATIVO
9AGF00624 DC
9AGF01171 9AGF00979
KO4AJ-0401HUE-C1
AO*18LFBC / RO-18LB / HOW-18LB
9AGF01005
EZ-0037HUE-C ROTATIVO
AO*24LMAM2 / ROM-24LA2 / HOM-24L2A AC
9AGF00569 9AGF00571
SOBRE PCB SOBRE PCB
CONTROL CONTROL
KO4AW-0404HUE-C1 ROTATIVO
AO*30LMAW4 / ROM-30LA4 / HOM-30L4A DC
MULTI 9AGF01131 9AGF01010
9AGF00624
INVERTER
EZ-002KHUE-C
9AGF00340 (MULTI
EZ-0023WUE-P EZ-001AHUE-TR ROTATIVO
AO*30QMAM4 / ROM-30QA4 / HOM-30Q4A CENTRAL PCB ASSY AC
9AGF00342 9AGF00339 9AGF00759
EZ-0030HUE-C
9AGF00486)
EZ-002UHUE-C
AO*14LSAWC / RO-14LAZ / HOW-14LAZ
SOBRE PCB 9AGF00426 EZ-002THUE-TR ROTATIVO
CONTROL 9AGF00428 9AGF00431
EZ-002THUE-C
AO*17LSAWC / RO-17LAZ / HOW-17LAZ
9AGF00427
EZ-003PHUE-C
AO*24LMAL / RO-24LA / HO-24LA
EZ-001AHUE-P 9AGF00909 EZ-001AHUE-TR TWIN ROTATIVO
AC
9AGF00857 9AGF00339 9AGF00712
EZ-003RHUE-C
AO*30LMAL / RO-30LA / HO-30LA
9AGF00942
9AGF00624
K03AV-041HUE-C1
AO*18LMAKL / ROT-18LA / HOT-18LA
SOBRE PCB 9AGF00918 TWIN ROTATIVO
GAMA CONTROL 9AGF00571
K03AV-042HUE-C1
AO*24LMAKL / ROT-24LA / HOT-24LA
COMERCIAL 9AGF00918
K04AW-0402HUE-C1
AO*30LMAWL / RO-30LB / HO-30LB
KO4BA-0401HUE-PO 9AGF01008 TWIN ROTATIVO
9AGF01009 SOBRE PCB 9AGF01010
KO4AW-0403HUE-C1
AO*36LMAWL / RO-36LA / HO-36LA
9AGF01014 CONTROL
KO4AW-0500HUE-C1
AO*45LJBYL / RO-45LB / HO-45LB DC
9AGF01230
K04AW-0401HUE-C1
AO*54LJAYL / RO-54LA / HO-54LA
9AGF00946
80