Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Creatinina
C enzimática AA
Método enzimático para la determinación de creatinina en
suero, plasma u orina
VALORES DE REFERENCIA
CALCULO DE LOS RESULTADOS Los valores esperados de creatinina son los siguientes:
Suero o plasma
1) Creatinina en suero (mg/l) = [(D2-B2) - (D1-B1) x k] x f Hombre: 7 - 13 mg/l
20 mg/l Mujer: 6 - 11 mg/l
f= Orina
(S2-B2) - (S1-B1) x k
Hombre: 0,8 - 2,0 g/24 hs
donde: Mujer: 0,6 - 1,8 g/24 hs
volumen del Blanco (ml) 2,57 ml Depuración de Creatinina Endógena
k = = = 0,673 Hombre: 94 - 140 ml/min (promedio 125 ml/min)
volumen final (ml) 3,82 ml Mujer: 72 - 110 ml/min
Significa la compensación por dilución del blanco por agre- Es recomendable que cada laboratorio establezca sus pro-
gado del Reactivo B. pios valores de referencia.
Ejemplo:
CONVERSION DE UNIDADES AL SISTEMA SI
B1: 0,123 S1: 0,145 D1: 0,164 Creatinina (mg/l) x 8,84 = Creatinina (umol/l)
B2: 0,137 S2: 0,365 D2: 0,412
Standard: 20 mg/l LIMITACIONES DEL PROCEDIMIENTO
k = 0,673 Ver Sustancias interferentes conocidas en MUESTRA.
20 (mg/l) 20 PERFORMANCE
f = = = a) Reproducibilidad: procesando sueros de acuerdo al
(0,365-0,137) - (0,145-0,123) x 0,673 0,228-0,022 x 0,673 documento EP5A del CLSI se obtuvo lo siguiente:
20 20 Precisión intraensayo (n = 20)
= = = 93,9 Nivel D.S. C.V.
0,228 - 0,015 0,213 0,98 mg/dl ± 0,014 mg/dl 1,45 %
3,80 mg/dl ± 0,038 mg/dl 0,99 %
Creatinina (mg/l) = [(0,412-0,137) - (0,164-0,123) x 0,673] x 93,9 =
Precisión total (n = 20)
= (0,275 - 0,041 x 0,673) x 93,9 = (0,275 - 0,028) x 93,9 =
Nivel D.S. C.V.
= 0,247 x 93,9 = 23,19 0,98 mg/dl ± 0,019 mg/dl 1,99 %
3,80 mg/dl ± 0,044 mg/dl 1,15 %
2) Creatinina en orina (g/24 hs) =
b) Linealidad: la reacción es lineal hasta 170 mg/l (17 mg/dl)
Creatinina (mg/l) x 50 x D Creatinina (mg/l) x D de creatinina. Para valores superiores, diluir la muestra 1:2
= = ó 1:4 con agua destilada y repetir la determinación. Corregir
1000 20 los cálculos multiplicando por el factor de dilución empleado.
c) Sensibilidad analítica: depende del fotómetro empleado
donde: y de la longitud de onda. En espectrofotómetros a 546 nm
D = volumen de la diuresis expresado en litros/24 hs con cubetas de caras paralelas de 1 cm de espesor, para
50 = factor de dilución un ∆A de 0,001 el mínimo cambio de concentración detec
1000 = conversión de mg a gramos table será 1,2 mg/l.
860243024 / 00 p. 2 de 12
PARAMETROS PARA ANALIZADORES AUTOMATICOS SÍMBOLOS
Para las instrucciones de programación debe consultarse el Los siguientes símbolos se utilizan en todos los kits de
Manual del Usuario del Analizador en uso. reactivos para diagnóstico de Wiener lab.
Para la calibración, debe usarse Calibrador A plus de
Wiener lab. Este producto cumple con los requerimientos previstos
Corrosivo / Cáustico
Irritante
Calibr. Calibrador
b Control
b Control Positivo
c Control Negativo
h Número de catálogo
*
Marcado CE pendiente 860243024 / 00 p. 3 de 12
LINHA LÍQUIDA
Creatinina
C enzimática AA
Método enzimático para a determinação de creatinina
em soro, plasma ou urina
VALORES DE REFERÊNCIA
CÁLCULO DOS RESULTADOS Os valores esperados de creatinina são os seguintes:
Soro ou plasma
1) Creatinina em soro (mg/l) = [(D2-B2) - (D1-B1) x k] x f
Homen: 7 - 13 mg/l
20 mg/l Mulher: 6 - 11 mg/l
f= Urina
(P2-B2) - (P1-B1) x k
Homen: 0,8 - 2,0 g/24 hs
onde: Mulher: 0,6 - 1,8 g/24 hs
volume do Branco (ml) 2,57 ml Depuração de Creatinina Endógena
k = = = 0,673 Homen: 94 - 140 ml/min (média 125 ml/min)
volume final (ml) 3,82 ml Mulher: 72 - 110 ml/min
Significa a compensação por diluição do branco por adição É recomendável que cada laboratório estabeleça seus pró-
do Reagente B. prios valores de referência.
Exemplo:
CONVERSÃO DE UNIDADES AO SISTEMA SI
B1: 0,123 P1: 0,145 D1: 0,164 Creatinina (mg/l) x 8,84 = Creatinina (umol/l)
B2: 0,137 P2: 0,365 D2: 0,412
Padrão: 20 mg/l LIMITAÇÕES DO PROCEDIMENTO
k = 0,673 Vide Substâncias interferentes conhecidas em AMOSTRA.
20 (mg/l) 20 DESEMPENHO
f = = = a) Reprodutibilidade: processando soros segundo o docu-
(0,365-0,137) - (0,145-0,123) x 0,673 0,228-0,022 x 0,673
mento EP5A do CLSI, obteve-se o seguinte:
20 20 Precisão intra-ensaio (n = 20)
= = = 93,9 Nível D.P. C.V.
0,228 - 0,015 0,213 0,98 mg/dl ± 0,014 mg/dl 1,45 %
3,80 mg/dl ± 0,038 mg/dl 0,99 %
Creatinina (mg/l) = [(0,412-0,137) - (0,164-0,123) x 0,673] x 93,9 =
Precisão total (n = 20)
= (0,275 - 0,041 x 0,673) x 93,9 = (0,275 - 0,028) x 93,9 =
Nível D.P. C.V.
= 0,247 x 93,9 = 23,19 0,98 mg/dl ± 0,019 mg/dl 1,99 %
3,80 mg/dl ± 0,044 mg/dl 1,15 %
2) Creatinina em urina (g/24 hs) =
b) Linearidade: a reação é linear até 170 mg/l (17 mg/dl)
Creatinina (mg/l) x 50 x D Creatinina (mg/l) x D de creatinina. Para valores superiores, diluir a amostra 1:2
= = ou 1:4 com água destilada e repetir a determinação. Corrigir
1000 20 os cálculos multiplicando pelo fator de diluição empregado.
c) Sensibilidade analítica: depende do fotômetro empregado
onde: e da comprimento de onda. Em espectrofotômetros a 546 nm
D = volume da diurese expresso em litros/24 hs com cubetas de faces paralelas de 1 cm de espessura,
50 = fator de diluição para um ∆A de 0,001 a mudança mínima de concentração
1000 = conversão de mg a gramas detectável será de 1,2 mg/l.
860243024 / 00 p. 5 de 12
PARÂMETROS PARA ANALISADORES AUTOMÁTICOS SÍMBOLOS
Para a programação consultar o Manual do Uso do anali- Os seguintes símbolos são utilizados nos kits de reagentes
sador a ser utilizado. para diagnóstico da Wiener lab.
Para a calibração deve-se utilizar o Calibrador A plus da
Wiener lab. Este produto preenche os requisitos da Diretiva Europeia
Corrosivo / Caústico
Irritante
Calibr. Calibrador
b Controle
b Controle Positivo
c Controle Negativo
h Número de catálogo
Creatinina
C enzimática AA
Enzymatic method for creatinine determination in
serum, plasma or urine
SUMMARY SAMPLE
Creatinine, a highly diffusible compound, is eliminated from Serum, plasma or urine
the body almost exclusively by renal filtration. a) Collection: obtain serum or plasma in the usual way.
Creatinine measurement in serum as well as the endogenous Two-hour or 24-hour urine could also be employed. Use a
creatinine clearance are important parameters for the diag- thoroughly cleaned container, which should be refrigerated
nosis of various renal disorders. (2-10oC) during collection. Measure diuresis, take an aliquot
and perform a 1:50 dilution. For a 2-hour diuresis, multiply
PRINCIPLE measured volume by 12 to calculate the amount of creatinine
Based on the following reaction system: eliminated during 24 hours.
creatininase b) Additives: in case the sample to be used is plasma, it is
creatinine + H2O creatine recommended the use of heparin as anticoagulant.
creatinase c) Known interfering substances: no interference has been
creatine + H2O sarcosine + urea observed with ascorbic acid up to 100 mg/l, hemoglobin up
sarcosine
oxidase to 400 mg/dl (4 g/l), bilirubin up to 28 mg/dl (280 mg/l) and
sarcosine + H2O + O2 glycine + HCHO + H2O2 triglycerides up to 1250 mg/dl (12.5 g/l).
peroxidase See Young, D.S. under References for effect of drugs on
H2O2 + 4-AP + TOOS quinoneimine dye the present method.
The intensity of the quinoneimine dye color formed is directly d) Stability and storage instructions: serum or plasma
proportional to the creatinine concentration in the sample. should be separated from cells within 2 hours after collec-
tion. If specimens are stored, protected from light, at 2-10oC,
PROVIDED REAGENTS stability is sustained for 3 days.
A. Reagent A: solution containing 36 kU/l creatinase, 11 kU/l Urine sample should be stored at 2-10oC for up 4 days without
sarcosine oxidase, 300 kU/l catalase, 3 kU/l ascorbate oxidase any preservatives.
and 20 mmol/l Goods buffer pH 8.2 with 1 mmol/l N-ethyl-N-
(2-hydroxy-3-sulfopropyl)-3-methylaniline (TOOS). REQUIRED MATERIAL (non-provided)
B. Reagent B: solution containing 4 mmol/l 4-aminophe- - Spectrophotometer.
nazone (4-AP), 370 kU/l creatininase, 15 kU/l peroxidase, - Micropipettes or pipettes for measuring the stated volumes.
0.8 g/l sodium azide and 20 mmol/l Goods buffer pH 8.0. - Spectrophotometric cuvettes.
S. Standard*: 20 mg/l creatinine solution. - Water bath at 37oC.
- Stopwatch.
NON-PROVIDED REAGENTS
- Wiener lab.'s Calibrador A plus. ASSAY CONDITIONS
- Demineralized water. - Wavelength: 546 nm
- Reaction temperature: 37oC
INSTRUCTIONS FOR USE
Provided Reagents: ready to use.
PROCEDURE
WARNINGS Before sample addition, set the instrument to zero O.D.
Reagents are for "in vitro" diagnostic use. with distilled water. In three spectrophotometric labeled
Use the reagents according to the working procedures for cuvettes B (Blank), S (Standard) and U (Unknown), place
clinical laboratories. as follows:
The reagents and samples should be discarded according
B S U
to the local regulations in force.
Sample - - 0.07 ml
STABILITY AND STORAGE INSTRUCTIONS
Standard - 0.07 ml -
Provided Reagents: stable in refrigerator (2-10oC) until the
expiration date stated on the box. Do not expose at elevated Demineralized water 0.07 ml - -
temperatures for extended periods of time.
860243024 / 00 p. 8 de 12
90 ml: 3 x 20 ml Reagent A SYMBOLS
3 x 10 ml Reagent B The following symbols are used in the packaging for Wiener
(Cat. 1009612) lab. diagnostic reagents kits.
REFERENCES
P Authorized representative in the European Community
- Fossatti, P.; Prencipe, L.; Berti, G. - Clin. Chem. 29:1494
(1983).
V "In vitro" diagnostic medical device
- Curtis, C.A.; Ashwood, E.R. - Tietz Fundamentals of Clin. Contains sufficient for <n> tests
X
Chem. 5th Ed.: 422, 2001.
- Burtis, C.A.; Ashwood, E.R. - Tietz Textbook of Clin. Chem. H Use by
3rd Ed.:1808, 1996.
- Young, D.S. - "Effects of Drugs on Clinical Laboratory Tests", l Temperature limitation (store at)
AACC Press, 5th ed., 2000.
- CLSI: Clinical and Laboratory Standards Institute (ex- Do not freeze
NCCLS) - Protocols EP 15A, 2001 / EP 17A, 2004.
F Biological risks
Cont. Contents
g Batch code
M Manufactured by:
Harmful
Corrosive / Caustic
Irritant
Calibr. Calibrator
b Control
b Positive Control
c Negative Control
h Catalog number
Creatinina
Nr kat. 1260362
C enzimática AA
Metoda enzymatyczna do oznaczania poziomu kreatyniny
Nr kat. 1009612
w surowicy krwi, osoczu lub moczu
Nr kat. 1009920
INSTRUKCJA UŻYCIA
PROCEDURA
Dostarczane odczynniki: gotowe do użycia.
Przed dodawaniem materiału ustawić aparat na zero O.D.
Na wodzie destylowanej. W trzech kuwetach spektrofo-
OSTRZEŻENIA
tometrycznych oznaczonych B (Ślepa), S (wzorcowa), U
Odczynniki do zastosowania diagnostycznego "in vitro".
(badana) umieścić:
Stosować odczynniki zgodnie z procedurami dla laboratoriów
klinicznych. Odczynniki i materiał badany należy odrzucić B S U
zgodnie z lokalnymi przepisami. Materiał badany - - 0,07 ml
TRWAŁOŚĆ I WARUNKI PRZECHOWYWANIA Próba wzorcowa - 0,07 ml -
Dostarczone odczynniki: przechowywać w lodówce (2-10oC) Woda
do końca daty ważności umieszczonej na opakowaniu. Unikać 0,07 ml - -
demineralizowana
ekspozycji na wyższe temperatury przez dłuższy okres czasu.
*Niedostarczane we wszystkich rozmiarach zestawów 860243024 / 00 p. 10 de 12
METODA KONONTROLI JAKOŚCI
Odczynnik A 2,5 ml 2,5 ml 2,5 ml
W trakcie przeprowadzania badania, należy przeprowadzić
Wymieszać i inkubować przez 5 minut w temperaturze analizę na dwóch poziomach (Standatrol S-E 2 niveles) ze
37oC. Odczytać absorbancję przy długości fali 546 nm znanym stężeniem kreatyniny.
(B1, S1, i U1).
Odczynnik B 1,25 ml 1,25 ml 1,25 ml WARTOŚCI REFERENCYJNE
Oczekiwane wartości kreatyniny są następujące:
Wymieszać i inkubować przez 5 minut w temperaturze
37oC. Odczytać absorbancję przy długości fali 546 nm Osocze lub surowica
(B2, S2, i U2). Mężczyźni: 7 - 13 mg/l
Kobiety: 6 - 11 mg/l
Mocz
OBLICZENIA Mężczyźni: 0,8 - 2,0 g/24 godz.
1) Kreatynina w surowicy (mg/l) = [(U2-B2) - (U1-B1) x k] x f Kobiety: 0,6 - 1,8 g/24 godz.
20 mg/l Endogenny Klirens Kreatyniny
f= Mężczyźni: 94 - 140 ml/min (125 ml/min średnia)
(S2-B2) - (S1-B1) x k
Kobiety: 72 - 110 ml/min
gdzie: Zaleca się dla każdego laboratorium ustalenie własnych
Objętość próby ślepej (ml) 2,57 ml wartości referencyjnych.
k = = = 0,673
końcowa objętość (ml) 3,82 ml KONWERSJA JEDNOSTEK SI
Uwzględnienie kompensacji roztworu próby ślepej przez Kreatynina (mg/l) x 8,84 = Kreatynina (umol/l)
dodanie Odczynnika B
Przykład: OGRANICZENIA PROCEDURY
Zobacz ZNANE INTERAKCJE w rozdziale MATERIAŁ.
B1: 0,123 S1: 0,145 U1: 0,164
B2: 0,137 S2: 0,365 U2: 0,412
CHARAKTERYSTYKA TESTU
Próba wzorcowa: 20 mg/l a) Powtarzalność: zgodnie z wytycznymi zawartymi w doku-
k = 0,673 mencie CLSI EP5-A uzyskano następujące dane:
20 (mg/l) 20 Precyzja w trakcie badania (n = 20)
f = =
(0,365-0,137) - (0,145-0,123) x 0,673 0,228-0,022 x 0,673 Poziom S.D. C.V.
0,98 mg/dl ± 0,014 mg/dl 1,45 %
20 20 3,80 mg/dl ± 0,038 mg/dl 0,99 %
= = = 93,9
0,228 - 0,015 0,213 Całkowita precyzja (n = 20)
Kreatynina (mg/l) = [(0,412-0,137) - (0,164-0,123) x 0,673] Poziom S.D. C.V.
0,98 mg/dl ± 0,019 mg/dl 1,99 %
x 93,9 = (0,275 - 0,041 x 0,673) x 93,9 =
3,80 mg/dl ± 0,044 mg/dl 1,15 %
= (0,275 - 0,028) x 93,9 = 0,247 x 93,9 = 23,19
b) Linijność: reakcja jest linijna do wartości 170 mg/l
2) Kreatynina w moczu (g/24 h) = (17 mg/dl) kreatyniny. Dla wyższych wartości należy
Kreatynina (mg/l) x 50 x U kreatynina (mg/l) x U powtórzyć badanie z rozcieńczeniem próbki 1:2 lub 1:4 w rozt-
= = worze soli fizjologicznej, a następnie w obliczeniach pomnożyć
1000 20 wyniki przez współczynnik rozcieńczenia.
gdzie: c) Czułość analityczna: w spektrofotometrze przy długości
U = Objętość diurezy wyrażona w litrach/24 godz. pomiaru 546 nm i długości optycznej kuwety 1 cm przy
50 = współczynnik rozcieńczenia ∆A min. = 0,001, najmniejsza wykrywalna różnica stężeń
1000 = konwersja mg na gramy wynosić będzie 1,2 mg/l.
3) Endogenny Klirens Kreatyniny (ang. Endogenous Crea-
tinine Clearance E.C.C.): PARAMETERY DLA ANALIZATORÓW AUTOMATYCZNCH
Celem programowania analizatorów automatycznych należy
Kreatynina w moczu (g/24 godz.) zapoznać się z podręcznikiem użytkownika zastosowanego apara-
E.C.C. (ml/min) = x 694 ml/min tu. Do kalibracji należy stosować Wiener lab.’s Calibrador A plus.
Kreatynina w surowicy (mg/l)
gdzie: WIENER LAB. DOSTARCZA
g/24 godz. 1000 mg x 1000 ml 1 000 000 ml 60 ml: 1 x 40 ml Odczynnik A
694 ml/min = = = 1 x 20 ml Odczynnik B
mg/l 1 mg x 1440 min 1440 min (Nr kat. 1260362)
860243024 / 00 p. 11 de 12
90 ml: 3 x 20 ml Odczynnik A Oznaczenia
3 x 10 ml Odczynnik B Następujące symbole są zastosowane na opakowaniach
(Nr kat. 1009612) zestawów odczynników diagnostycznych.
Ten produkt spełnia wymagania Dyrektywy Europej-
90 ml: 3 x 20 ml Odczynnik A
3 x 10 ml Odczynnik B C skiej 98/79 EC dla wyrobów medycznych używanych
do diagnozy "in vitro"
(Nr kat. 1009920)
PAutoryzowany przedstawiciel we Wspólnocie Europejskiej
ŹRÓDŁA V Wyrób do diagnostyki "in vitro"
- Fossatti, P.; Prencipe, L.; Berti, G. - Clin. Chem. 29:1494
(1983). X Zawartość wystarczająca dla <n> badań
- Curtis, C.A.; Ashwood, E.R. - Tietz Fundamentals of Clin. Użyć przed
Chem. 5th Ed.: 422, 2001. H
- Burtis, C.A.; Ashwood, E.R. - Tietz Textbook of Clin. Chem. l Ograniczenie dopuszczalnych temperatur
3rd Ed.:1808, 1996.
- Young, D.S. - "Effects of Drugs on Clinical Laboratory Nie zamrażać
Tests", AACC Press, 5th ed., 2000.
F Ryzyko biologiczne
- CLSI: Clinical and Laboratory Standards Institute (ex-
NCCLS) - Protocols EP 15A, 2001 / EP 17A, 2004. Objętość po rozpuszczeniu
Cont. Zawartość
g numer serii
M Wytwórca
Substancja szkodliwa
Substancja żrące
Substancja drażniąca
Calibr. Kalibrator
b Próba kontrolna
h Numer katalogowy
Wiener lab.
2000 - Rosario - Argentina
http://www.wiener-lab.com.ar
Dir. Téc.: Viviana E. Cétola
Bioquímica
Producto Inscripto M.S.
Cert. Nº: 5708/05 2000 Rosario - Argentina
860243024 / 00 p. 12 de 12 UR190524