Do = 0.01905 m
Xw = 0.01244 m
PT = 15/16” = 0.02381 m
TCb = 29 °C
TCa = 23 °C
o = 996.7 kg/m3
ko = 0.5326 Kcal/hrmºC
Pro = 6.066
mh = 9000 kg/hr
Tha = 50 °C
Thb = 30 °C
i = 0.654x10-3 kg/mseg
ki = 0.543 Kcal/hrmºC
Pri = 4.33
suponiendo
NP = 2
Tc+Th 26+ 40
Tw= = =33° C
2 2
( 50−24 )−(30−23)
∆ Tm= =12.74
(50−24)
ln
(30−23)
50−30 29−23
R= =3.33 S= =0.222
29−23 50−23
FT = 0.905
Af = mi /vi i
9000
Á rea por paso= =0.063 m2
( 1440 ) (992.2)
mi 9000 kg/hr
v corr = =
Af ρ i ( 0.00603 ) ¿ ¿
D i v i ρi
ℜi = =( 0.0165 m ) ¿ ¿
μi
ki
hi =0.023 ¿
Di
Φi = 0.9798
0.543
hi =0.023 ¿
0.01656
hi = 1974.82
Calculo de ho
C’ = PT – Do = 4.76x10-3 m
B = Ds/5 = 0.0508 m
29992.19
Gs = −3
=3229.13 kg /m 2 s
( 2.58 × 10 ) (3600)
De = 0.01338 m
DeG s
ℜo= = ( 0.01336 m) ¿ ¿
μo
ho = 10073.1
ho 10073.11
Tw corr =Th− ( )
h o +hi
( Th−Tc ) =40−
10073.11+1974.82
(40−26)=28.29
Do−Di 0.01905−0.01656
Dm= = =0.01776 m
Do 0.01905
ln ln
Di 0.01656
1
Uo=
Do 1
+ Rw + + Rdi+ Rdo
hi di ho
1
Uo=
0.01905 −6 1 −4 −4
+ 4.002× 10 + +1.02× 10 +1.53 ×10
( 1974.82 ) (0.01656) 10073.4
Uo = 1062.91 kcal/m2hrºC
Qg 179766
Ao = = =14.668 m 2
U o ∆ Tm L FT ( 12.74 )( 1062.91 ) (0.905)
Ao = π Do L NT
Ao 14.668 m2
NT = = =51
π DoL π ( 0.01905 ) (4.8 m)
Pi = (fivi2LNPi)/(2gCDi)
La caída de presión dentro de los tubos está dentro del valor permitido.
Caída de presión en la coraza
Po = (foGS2(N+1)DI)/(2gCDeo)
∆ Po =( 0.0389 ) ( 4.8 ) ¿ ¿
2
ΔP o =0 . 0064 kg f /cm
Ao 14.668 m2
L= = =4.37 m
π DoNt π ( 0.01905 ) (56)
2. Un intercambiador de calor de carcasa y tubos será usado para enfriar 90800 kg/hr de una
solución de sacarosa desde 37.7 ºC a 32.2 ºC, el intercambiador es del tipo 1-2, a través de la
coraza fluye agua tratada que entra a 23.8 ºC y sale a 32.2 ºC se usaran tubos de cobre de 1”
BWG 18 y 4.87 m de longitud con un espaciado de 1.25 plg ¿Cuál es el intercambiador de calor
adecuado si se permite una caída de presión total de 0.8 kg/cm2?¿cual es el costo total por año?
Do = 0.0254 m
Xw = 0.01244 m
PT = 1” = 0.0254 m
Rdi = 2.04x10-4
Rdo = 7.68x10-4
Ds = 19 ¼” = 0.48895 m
Agua tratada
TCb = 32.2 °C
TCa = 23.8°C
o = 996.2 kg/m3
ko = 0.5274 Kcal/hrmºC
Pro = 5.748
Tha = 37.7 °C
Thb = 32.2 °C
i = 994.45 kg/m3
i = 0.727x10-3 kg/mseg
ki = 0.5365 Kcal/hrmºC
Pri = 4.88
suponiendo
NP = 2
Tc+Th 28+34.95
Tw= = =31.475 ° C
2 2
( 32.2−23.8 ) −(37.7−32.2)
∆ Tm= =6.9° C
(32.2−23.8)
ln
(37.7−32.2)
37.7−32.2 32.2−23.8
R= =0.65 S= =0.6
32.2−23.8 37.7−23.8
FT = 0.82
A f =mi/ v ii
90800
Á rea por paso= =0.025 m 2
( 3600 ) ( 994.45)
mi 90800 kg /hr
v corr = =
Af ρ i ( 0.02719m ) ¿ ¿
D i v i ρi
ℜi = =( 0.02291 m) ¿ ¿
μi
hi = 0.023(ki/Di)(Rei)0.8(Pr)0.33
Φi = 0.9905
0.8
hi =0 .023 (0 .5365/0 . 02291) ( 29232. 24 ) ( 4 .33 )0 . 33( 0. 9905 )
hi = 3365.075
ho = 4880
ho 3365.075
Tw corr =Th− ( )h o +hi
( Th−Tc ) =34.95−
4880+3365.075
(34.95−28)=32.11
Do−Di 0.0254−0.02291
Dm= = =0.0241 m
Do 0.0254
ln
Di
ln (
0.02291 )
XwDo ( 0.001224 m ) (0.0254 m)
Rw= =
KwDm ¿¿
1
Uo=
Do 1
+ Rw + + Rdi+ Rdo
hi di ho
1
Uo=
3.93 ×10 +3.29 ×10 +2.049× 10− 4+ 2.04 ×10−4 +7.68 ×10−4
−6 −4
Uo = 662.32 kcal/m2hrºC
Qg 498725.81
Ao = = =133.08 m2
U o ∆ Tm L FT ( 662.32 ) ( 6.9 ) (0.82)
Pi = (fivi2LNPi)/(2gCDi)
La caída de presión dentro de los tubos está dentro del valor permitido.
GS = mo/AS
AS = (BDsC’)/PT
B = Ds/5 = .0977 m
Ds = 0.48895 m
PT = 0.0254 m
C’ = PT – Do = .006 m
De=0.0239
59444.64
Gs = =181.057 kg /m2 seg
( 0.0912 ) (3600)
∆ Po =0.0034 kg f /cm2
3. En una nueva instalación es necesario precalentar 67585 kg/hr de aceite crudo de 34 ºAPI de
77 a 140 ºC, correspondiente al plato de alimentación de una torre fraccionaria. Hay una línea de
gasoil de 33 ºAPI que pasa cerca de la torre a 277 ºC, disponible en cantidades relativamente
ilimitadas. Debido a que el costo de bombeo de gasoil frío es prohibitivo, la temperatura de
gasoil del intercambiador de regreso a la línea no deberá ser menor de 149 ºC.
Se dispone de un intercambiador de calor 1-2 de 25 plg de Ds, con 252 tubos de 1 plg de
Do, 13 BWG y 16 pies de largo, arreglo en seis pasos en arreglo triangular de 1 ¼ de espaciado.
Los deflectores de la carcasa están espaciados 5 plg. Se permite una caída de presión de 10
lb/plg2 en el gasoil y de 15 lb/plg2 en la línea de alimentación.
DATOS
Nt=252
Di=0.020574m
BWG=13
Np= 6
L= 4.8768m
Xw= 0.002413m
B= 0.127m
Tca−Tcb
Tc=
2
Tc=108.5° C
Tha−Thb
Th=
2
Th=213 ° C
Qg = Qc
Qg=2299241.7 Kcal/hr
π 2 Nt
Af = Di
4 Np
π 252
Af = (0.020574 m)2
4 6
Af = 0.01396 m2
mi
v=
Af ρi
67585 kg /hr
v=
( 0.01396 m2) (760.8 kg/m3)
¿ ρi
ℜ=
μi
( 0.020574 m )( 1.76 m/s ) (760.8 kg /m 3 )
ℜ=
1.6 x 10−3 kg /ms
Re= 17217.96
Cpi μi
Pri=
Ki
Pri= 27.8709
Ki
h i=0.027 ( ) Di
( ℜ)0.8 ( Pri)0.33 φi
h i=0.027 ( 0.11160.020574
Kcal /mhr ° C
m )( 17217.96) 0.8
( 27.8709)0.33 φi
hi= 1074.96 φ i
KO DeGs 0.55
ho=0.36 ( )( De µc ) Pr 0.33
o φo
0.55
0.1027 Kcal /mhr ° C ( 0.01785 m ) ( 483.37 kg/m 2 s)
h o=0.36 ( 0.01785 m )( 0.7 x 10−3 kg/ms ) (15.7039)0.33 φo
ho=841.37 φ o
Cpo μo
Pro=
Ko
Pro= 15.7039
Pt 2
De=1.09 −Do
Do
( 0.03175 m)2
De=1.09 −0.0254 m
0.0254 m
De=0.01785m
c´=Pt-Do=0.03175m-0.0254m
c´=6.35x10-3m
BDsc´
As=
Pt
As=0.016129m2
mo
Gs=
As
28066.915 kg /hr
Gs=
0.016129 m2
Th+ Tc
Twp=
2
213+108.5
Twp=
2
Twp=160.75 °C
µw @ Twp
µwi=0.75x10-3 kg/ms
µwo=1.2x10-3 kg/ms
0.14
1.6 x 10−3
hi=1074.96 ( 0.75 x 10−3 )
hi=1195.25 Kcal/hrm2°C
0.14
0.7 x 10−3
ho=841.37 (
1.2 x 10−3 )
ho=780.21 Kcal/hrm2°C
Twc1=149.77 °C
µw @ Twc1
µwi=0.8x10-3 kg/ms
µwo=1.3x10-3 kg/ms
0.14
1.6 x 10−3
hi=1074.96 ( 0.8 x 10−3 )
hi=1184.5 Kcal/hrm2°C
0.14
0.7 x 10−3
ho=841.37 ( 1.3 x 10−3 )
ho=771.52 Kcal/hrm2°C
Twc2= 149.71 °C
1
Uo=
Do 1 XwDo
+ + + Rdi + Rdo
hi di ho KwDm
Do−Di
Dm=
Do
ln( )
Di
0.0254 m−0.020574 m
Dm=
0.0254 m
ln (
0.020574 m )
Dm=.0229m
1
Uo=
0.0254 1 ( 0.002413 ) (0.0254)
+ + + ( 2 ) (12.29 ×10−4)
( 1184.5 ) (0.020574) 771.52 ( 38.66 ) (0.0229)
Uo=205.52 Kcal/hrm2°C
277−149 140−77
R= =2.03 S= =0.31
140−77 277−77
Ft=0.89
Q
Ao=
Uo ∆TmFt
( Tha−Tcb )−(Thb−Tca )
∆ Tm=
(Tha−Tcb)
ln
(Thb−Tca)
( 277−140 )−(149−77)
∆ Tm=
(277−140)
ln
(149−77)
∆Tm= 101.039 °C
2299241.7
Ao=
( 205.52 )( 101.039 ) (.89)
Ao=124.4 m2
fiLNp V 2 ρi
∆ Pi=
2 gDi
fi= 0.4924Re-0.2741
fi= 0.4924(17217.96)-0.2741
fi=0.03398
( .03398 )( 4.8 m) ( 6 ) ( 1.76 m/s )2 ( 760.8 kg /m3 )
∆ Pi=
( 2 ) ( 9.8 m/s 2) ( 0.020574 m)
fo ( N +1 ) Gs2 Ds
∆ Po=
2 gDe ρo
L 4.8 m
N +1= = =37.79
B 0.127 m
DeGs
Reo=
μo
( 0.01785 m ) (483.37 kg /m 2 s)
Reo=
0.7 x 10−3 kg /ms
Reo=12325.93
fo= 1.775Re-0.1947
fi= 1.775(12325.93)-0.1947
fo=0.2836
2
( 0.2836 )( 37.79 m ) ( 483.37 kg /m2 s ) ( 0.635 m)
∆ Po=
( 2 ) ( 9.8 m/s2 ) ( 0.01785 m ) ( 662.475 kg /m3 )
DATOS
Nt=252
Di=0.020574m
BWG=13
Np= 6
L= 4.8m
Xw= 0.002413m
B= 0.127m
Tca−Tcb
Tc=
2
Tc=108.5° C
Tha−Thb
Th=
2
Th=213 ° C
ACEITE CRUDO (POR DENTRO) GAS OIL (POR FUERA)
34 O API 33 O API
mi=67585 kg/hr Tha=277 °C
Tca=77 °C Thb=149 °C
Tcb=140 °C ρ o=662.47 kg/m3
ρ i=760.8 kg/m3 µo=0.7 x 10-3 kg/ms
µi=1.6 x 10-3 kg/ms Ko= 0.1027 Kcal/mhr°C
Ki= 0.1116 Kcal/mhr°C Cpo=0.64 Kcal/kg°C
Cpi=0.54 Kcal/kg°C
Qg=Qc
Qg=2299241.7 Kcal/hr
π 2 Nt
Af = Di
4 Np
π 252
Af = (0.020574 m)2
4 6
Af=0.01396 m2
mi
v=
Af ρi
67585 kg /hr
v=
( 0.01396 m2) (760.8 kg/m3)
¿ ρi
ℜ=
μi
( 0.020574 m )( 1.76 m/s ) (760.8 kg /m 3 )
ℜ=
1.6 x 10−3 kg /ms
Re= 17217.96
Cpi μi
Pri=
Ki
Pri= 27.8709
Ki
h i=0.027 ( ) Di
( ℜ)0.8 ( Pri)0.33 φi
h i=0.027 ( 0.11160.020574
Kcal /mhr ° C
m )( 17217.96) 0.8
( 27.8709)0.33 φi
hi= 1074.96 φ i
KO DeGs 0.55
ho=0.36 ( )( De µc ) Pr 0.33
o φo
0.55
0.1027 Kcal /mhr ° C ( 0.01785 m ) ( 483.37 kg/m 2 s)
h o=0.36 ( 0.01785 m )( 0.7 x 10−3 kg/ms ) (15.7039)0.33 φo
ho=841.37 φ o
Cpo μo
Pro=
Ko
Pro= 15.7039
Pt 2
De=1.09 −DO
Do
( 0.03175 m)2
De=1.09 −0.0254 m
0.0254 m
De=0.01785m
c´=Pt-Do=0.03175m-0.0254m
c´=6.35x10-3m
BDsc´
As=
Pt
As=0.016129m2
mo
Gs=
As
28066.915 kg /hr
Gs=
0.016129 m2
Th−Tc
Twp=
2
213−108.5
Twp=
2
Twp=160.75 °C
µw @ Twp
µwi=0.75x10-3 kg/ms
µwo=1.2x10-3 kg/ms
hi=1074.96(1.6x10-3 /0.75x10-3)0.14
hi=1195.25 Kcal/hrm2°C
ho=841.37(0.7x10-3/1.2x10-3)0.14
ho=780.21 Kcal/hrm2°C
Twc 1=Th− ( hihi +ho ) ( Th−Tc )
Twc 1=213− ( 1195.25
1195.25
+780.21) ( 213−108.5 )
Twc1=149.77 °C
µw @ Twc1
µwi=0.8x10-3 kg/ms
µwo=1.3x10-3 kg/ms
0.14
1.6 x 10−3
hi=1074.96 ( 0.8 x 10−3 )
hi=1184.5 Kcal/hrm2°C
0.14
0.7 x 10−3
ho=841.37 ( 1.3 x 10−3 )
ho=771.52 Kcal/hrm2°C
Twc2= 149.71 °C
1
Uo=
Do 1 XwDo
+ + + Rdi + Rdo
hi di ho KwDm
Do−Di
Dm=
Do
ln( )
Di
0.0254 m−0.020574 m
Dm=
0.0254 m
ln (
0.020574 m )
Dm=.0229m
1
Uo=
( 1184.50.0254
×0.020574 ) +(
1
771.53 ) +(
0.002413× 0.0254
38.66× 0.0229 )
+ ¿¿
Uo=205.52 Kcal/hrm2°C
277−149 140−77
R= =2.03 S= =0.31
140−77 277−77
Ft=0.89
Q
Ao=
Uo ∆TmFt
( Tha−Tcb )−(Thb−Tca)
∆ Tm=
(Tha−Tcb)
ln
(Thb−Tca)
( 277−140 )−(149−77)
∆ Tm=
(277−140)
ln
(149−77)
∆Tm= 101.039 °C
2299241.7
Ao=
( 205.52 )( 101.039 ) (.89)
Ao=124.4 m2
fiLNp V 2 ρi
∆ Pi=
2 gDi
fi= 0.4924Re-0.2741
fi= 0.4924(17217.96)-0.2741
fi=0.03398
fo ( N +1 ) Gs2 Ds
∆ Po=
2 gDe ρo
L 4.8 m
N +1= = =37.79
B 0.127 m
DeGs
Reo=
μo
( 0.01785 m ) (483.37 kg /m 2 s)
Reo=
0.7 x 10−3 kg /ms
Reo=12325.93
fo= 1.775Re-0.1947
fo= 1.775(12325.93)-0.1947
fo=0.2836
2
( 0.2836 )( 37.79 m ) ( 483.37 kg /m2 s ) ( 0.635 m)
∆ Po=
( 2 ) ( 9.8 m/s2 ) ( 0.01785 m ) ( 662.475 kg /m3 )
DATOS
Di=0.021183m
BWG=14
Np= 6
L= 3m
Xw= 0.002108m
Tca−Tcb
Tc=
2
Tc=108.5° C
Tha−Thb
Th=
2
Th=213 ° C
Qg=Qc
Qg=2299241.7 Kcal/hr
Q
m o= Cp ¿
∆¿ o
mi
Af =
v ρi
67585 kg/hr
Af =
(1.8 ms )(760.8 kg /m )∗3600
3
Af= 0.01265 m2
Af
Nt= × Np
π 2
Di
4
0.01265 m2
Nt= ×6
π( 2
0.02118 m )
4
Nt= 215.4
Ntc=212 (tablas)
π 2 Nt
Af = Di
4 Np
π 212
Af = (0.02118 m)2
4 6
Afc= 0.01245 m2
mi
vc=
Afc ρi
67585 kg /hr
vc=
( 0.01245 m2 ) (760.8 kg /m3)
DiVc ρ i
ℜ=
μi
Re= 19960
Cpi μi
Pri=
Ki
Pri= 27.8709
Ki
h i=0.027 ( ) Di
( ℜ)0.8 ( Pri)0.33 φi
h i=0.027 ( 0.11160.02118
Kcal /mhr ° C
m )( 19960) 0.8
( 27.8709)0.33 φi
hi= 1175.25 φ i
KO DeGs 0.55
ho=0.36 ( )(De μo ) 0.33
Pr o φ o
0.55
0.1027 Kcal /mhr ° C ( 0.01785 m ) (560 kg /m2 s )
ho=0.36 ( 0.01785 m )( 0.7 x 10−3 kg /ms ) (15.7039)0.33 φo
ho=991.48 φ o
Cpo μo
Pro=
Ko
Pro= 15.7039
Pt 2
De=1.09 −Do
Do
( 0.03175 m)2
De=1.09 −0.0254 m
0.0254 m
De=0.01785m
C´=Pt-Do=0.03175m-0.0254m
C´=6.35x10-3m
BDsC ´
As=
Pt
As=0.0139m2
mo
Gs=
As
28066.915 kg /hr
Gs=
0.0139 m2
Gs=2016000 Kg/m2hr = 560 kg/m2s
Th−Tc
Twp=
2
213−108.5
Twp=
2
Twp=160.75 °C
µw @ Twp
µwi=0.75x10-3 kg/ms
µwo=1.2x10-3 kg/ms
0.14
1.6 x 10−3
hi=1175.25 (
0.75 x 10−3 )
hi=1304.52 Kcal/hrm2°C
0.14
0.7 x 10−3
ho=991.48 (
1.2 x 10−3 )
ho=930.15 Kcal/hrm2°C
Twc1=151.99 °C
µw @ Twc1
µwi=0.8x10-3 kg/ms
µwo=1.3x10-3 kg/ms
0.14
1.6 x 10−3
hi=1175.25 ( 0.8 x 10−3 )
hi=1295 Kcal/hrm2 °C
0.14
0.7 x 10−3
ho=991.48 (
1.3 x 10−3 )
ho=909.09 Kcal/hrm2°C
Twc2= 151.6 °C
1
Uo=
Do 1 XwDo
+ + + Rdi + Rdo
hi di ho KwDm
Dm= (Do-Di)/ln(Do/Di)
Dm=(0.0254m-0.02118m)/ln(0.0254m/0.02118m)
Dm=.02322m
1
Uo=
0.0254 1 0.002108× 0.0254
( 1295× 0.02118
+ )(
909.09
+ )(
38.66× 0.02322 )
+ ( 2∗12.29 x 10−4 )
Uo=220.08 Kcal/hrm2°C
277−149 140−77
R= =2.03 S= =0.31
140−77 277−77
Ft=0.89
Q
Ao=
Uo ∆TmFt
( Tha−Tcb )−(Thb−Tca )
∆ Tm=
(Tha−Tcb)
ln
(Thb−Tca)
( 277−140 )−(149−77)
∆ Tm=
(277−140)
ln
(149−77)
∆Tm= 101.039 °C
2299241.7
Ao=
( 220.08 ) (101.039 )( .89)
Ao=121.78 m2
fiLNp V 2 ρi
∆ Pi=
2 gDi
fi= 0.4924Re-0.2741
fi= 0.4924(19960)-0.2741
fi=0.0428
fo ( N +1 ) Gs2 Ds
∆ Po=
2 gDe ρo
L 3m
N +1= = =25.40
B 0.1181 m
DeGs
Reo=
μo
( 0.01785 m ) (560 kg /m 2 s)
Reo=
0.7 x 10−3 kg /ms
Reo=14280
fo= 1.775Re-0.1947
fo= 1.775(14280)-0.1947
fo=0.2749
2
( 0.2749 )( 25.40 m ) ( 560 kg /m 2 s ) ( 0.59055 m )
∆ Po=
( 2 ) ( 9.8 m/ s 2 ) ( 0.01785 m ) ( 662.475 kg /m3 )
Intercambiador 1-2
De acuerdo a los datos proporcionados y a la siguiente regla se fija cual flujo va por dentro y
cual va por fuera en el intercambiador de calor.
De Tablas
S o*=0.82
ρH20=980.23 kg/m3
De Tablas
Calculo de las caídas de presión para comprobar cual de los dos arreglos proporciona la menor
f i LNp V 2 ρi
∆ Pi=
2 g c Di 10000
Balance de calor para conocer el flujo que va por dentro de los tubos
π 2 Nt
Af = Di
4 Np
π 338
Af = ( 0.021183 m )2 =2.98 ×10−2 m 2
4 4
mc
v=
Af ρi
43545 kg /hr
v= =2099.89 m/hr
( 2.98× 10−2 m2) (696.35 kg/m3 )
fi =0.4924(Re)-0.2741
fi =0.4924(318655.45)-0.2741=0.01527
Calculo de la caída de presión en los tubos
El ∆Po se obtiene para los dos arreglos ya que el diámetro equivalente cambia según el arreglo
elegido. Aunque los tubos se pueden arreglar en forma de cuadro o triangular, el arreglo
cuadrado tiene la ventaja de que es más fácil limpiarlos en la parte externa, el arreglo triangular
es preferido porque permite el uso de más tubos en un diámetro de carcasa dado, y también
provoca coeficientes de película mayores por fuera de los tubos.
Calculo del Diámetro equivalente para arreglo triangular. El diámetro equivalente es una función
del diámetro externo de los tubos, su espaciado y arreglo.
( 0.03175 m )2
De=1.09 −0.0254 m=0.01786 m
0.0254 m
fo ( N + 1 ) Gs2 Ds
∆ Po=
2 gc De ρo 10000
C´=Pt-Do
C´=0.03175m=-0.0254m 6.35x10-3m
BDsC ´
As=
Pt
mo
Gs=
As
103700 kg /hr
Gs= 2
=2771245.32kg /m 2 hr
0.03742 m
DeGs
ℜo=
μo
(0.01786)(2771245.32 kg /m2 hr)
ℜo=
( 2.28 x 10−3 kg /ms ) ¿ ¿
fo= 1.775Re-0.1947
fo= 1.775(6030.02)-0.1947=0.3260
L
( N +1 )=
B
4.8768 m
( N +1 )=
0.254 m
( 0.03175 m )2
De=1.27 −0.0254 m=0.025 m
0.0254 m
fo= 1.775Re-0.1947
fo= 1.775(8440.683)-0.1947=0.305
2
( 0.305 ) (19.2 ) ( 2771245.32 kg/m 2 hr ) ( 0.7366 m )
∆ Po= 2 2 3
=0.6530 kg/cm2
( 2 ) ( 9.8 m/s ) (3600) ( 0.025 m ) ( 798.89 kg/m ) 10000
TABLA DE RESULTADOS
kg /cm2 kg /cm2
ΔP i 0.01699 0.01699
ΔP o 0.977 0.6530
De acuerdo a los resultados obtenidos el mejor arreglo es el cuadrado ya que proporciona una
menor caída de presión en el intercambiador de calor
7. 19600 kg/hr de un destilado de 35 ºAPI es enfriado de 121 a 49 ºC usando agua tratada que se
calentara de 29 a 49 ºC. Se dispone para este servicio de un intercambiador 1-2 de 0.48895 m de
Ds que tiene 204 tubos de 3/4 plg Do, 16 BWG y 4.8 m de longitud, arreglados en cuadro con 1
plg de paso. Los deflectores se espacían 0.127 m y el haz esta arreglado para cuatro pasos. ¿Qué
arreglo dan las caídas de presión más balanceadas? (use la misma viscosidad del problema
anterior, para el destilado)
Intercambiador 1-2
El número de pasos en los tubos se fijará en 2 o más pasos, con esto tenemos la ventaja de poder
tener flujo turbulento, y poca resistencia de la pared, aunque puede existir mayor caída de
presión.
De acuerdo a los datos proporcionados y a las reglas siguientes se fija cual flujo va por dentro y
cual va por fuera en el intercambiador de calor.
De Tablas
De Tablas
Calculo de las caídas de presión para comprobar cual de los dos arreglos proporciona la menor
fiLNp V 2 ρ i
∆ Pi=
2 gDi 10000
Balance de calor para conocer el flujo que va por dentro de los tubos
Q= m Cpi∆T
π 2 Nt
Af = Di
4 Np
π 204
Af = (0.0 15748 m)2 =9.934 ×10−3 m2
4 4
mc
v=
Af ρi
37092.22kg /hr
v= =3763.33 m/hr
( 9.934 ×10−3 m2 ) (992.2 kg /m3)
fi= 0.4924Re-0.2741
fi= 0.4924(24975.64)-0.2741=0.031
Calculo del Diámetro equivalente para arreglo triangular. El diámetro equivalente es una función
del diámetro externo de los tubos, su espaciado y arreglo.
( 0.025 4 m )2
De=1.09 −0.01905 m=0.01786 m
0.0 1905 m
C´=Pt-Do=0.0254m-0.01905m
C´=6.35x10-3m
fo ( N +1 ) Gs2 Ds
∆ Po=
2 gDe ρo
BDsC ´
As=
Pt
As=0.016129m2
mh
Gs=
As
19600 kg / hr
Gs= 2
=1262888.598 kg/m 2 hr
0.01 552m
L 4.8 m
N +1= = =37.79
B 0.127 m
DeGs
ℜo=
μo
( 0.01786 m )(1262888.598 kg /m 2 hr )
ℜo= =3659.65
(1.712 x 10−3 kg /ms)(3600)
fo= 1.775Re-0.1947
fo= 1.775(3659.65)0.1947 = 0.3592
( 0.0 254 m )2
De=1.27 −0.0 1905 m=0.02396 m
0.01905 m
( 0.02396 m )(1262888.598 kg /m 2 h)
ℜo= =4909.59
(1.712 x 10−3 kg/ms)(3600)
TABLA DE RESULTADOS
kg/cm2 kg/cm2
ΔP i 0.21 0.21
ΔP o 0.31 0.2232
De acuerdo a los resultados obtenidos el mejor arreglo es el cuadrado ya que proporciona una
menor caída de presión en el intercambiador de calor.
8. 35543 kg/hr de isobutano (70 ºAPI) se enfrían de 95 a 82 ºC por el calentamiento de butano
(65 ºAPI) de 68 a 80 ºC. Para este servicio se dispone de un intercambiador 1-2 de 0.43815 m Ds
que tiene 178 tubos de 3/4 plg D0, 14 BWG y 3.6576 m de largo, en arreglo triangular de 1 plg
de paso. Los deflectores están espaciados a 0.1524 m, y el haz de tubos está arreglado para
cuatro pasos. ¿Cuáles son las caídas de presión?
Datos proporcionados del intercambiador
De Tablas
(Flujo que va por fuera)
S o*=0.767 K o=0.09 BTU/hrft°F K o=0.13392 Kcal/hrm°C
Cp o=0.66 Kcal/kg°C µo=0.115 x 10-3 Kg/ms ρH20=975.4 Kg/m3
ρo=(0.67)(975.4kg/m3)=653.52 kg/m3
De Tablas
(Flujo que va por dentro)
S i*=0.635 K i=0.0915BTU/hrft°F Ki=0.13615 Kcal/hrm°C
Cp i=0.66 Kcal/kg°C µi=0.11 x 10-3 kg/m ρH20=966.27 kg/m3
ρi=(0.635)( 966.27 kg/m3)
Calculo de las caídas de presión para comprobar cual de los dos arreglos proporciona la
menor
fiLNp v 2 ρ i
∆ Pi=
2 gDi 10000
Balance de calor para conocer el flujo que va por dentro de los tubos
Q= m Cpi∆T
π 2 Nt
Af = Di
4 Np
π 178
Af = (0.0 14833 m)2 =7.69 ×10−3 m2
4 4
mc
v=
Af ρi
38504.92 kg /hr
v= =7532.8 m/hr
( 7.69× 10−3 m2 ) (613.58 kg/m3)
fi= 0.4924Re-0.2741
fi= 0.4924(173125.66)-0.2741=0.01805
Calculo del Diámetro equivalente para arreglo triangular. El diámetro equivalente es una
función del diámetro externo de los tubos, su espaciado y arreglo.
( 0.025 4 m )2
De=1.09 −0.01905 m=0.017865m
0.0 1905 m
C´=Pt-Do=0.0254m-0.01905m
C´=6.35x10-3m
fo ( N +1 ) Gs2 Ds
∆ Po=
2 gDe ρo
BDsc´
As=
Pt
mh
Gs=
As
38504.92 kg/hr
Gs= 2
=2307065.31 kg /m2 hr
0.01669 m
L 3.6576 m
N +1= = =24
B 0.1524 m
DeGs
ℜo=
μo
fo= 1.775Re-0.1947
TABLA DE RESULTADOS
Kg/cm2
ΔP i 0.2440
ΔP o 0.3564
9. 27216 kg/hr de una solución de NaCl al 25% se enfría de 66 a 38 ºC usando agua con
una temperatura de entrada de 27 ºC y salida de 38 °C. Se dispone para el servicio de un
intercambiador 1-2 de 0.5398 m Ds, que tiene 302 tubos de 3/4 plg Do, 14 BWG, 1.829 m
de largo. Los deflectores están espaciados a 0.127 m, y el haz de tubos está arreglado para
dos pasos. ¿Cuáles son las caídas de presión?
Datos:
Di = 0.014833 m
Do = 0.01905 m
BWG14
Xw = 2.1082x10-3 m
Arreglo triangular
Np = 2
Ds = 0.5398m
Nt = 302
L = 1.829m
B = 0.127m
Fluido Caliente:
Solución de NaCl al 25 %
mh = 27216 kg/hr
Tha = 66 °C
Thb = 38 °C
ρh = 1,174.67 kg/m3
µh = 3.528 kg/mhr
Fluido Frio:
Tca = 27 °C
Tcb = 38 °C
ρc = 994.825 kg/m3
µc = 2.7513 kg/mhr
Qc=mh Cp h ∆ T h
Qc = 629451.64 Kcal/hr
Qg=m c Cp c ∆ T c
mc = 57301.66 kg/hr
Cálculo de caídas de presión con la solución de NaCl fluyendo por los tubos:
π 2 Nt
Af = Di
4 Np
π 302
Af = (0.014833)2
4 2
Af =0.02609 m 2
mh
v=
Af ρh
27216 kg /hr
v= 2 3
(0.02609 m )(1174.67 kg/m )
v=888.043 m/hr
DiVρ
ℜ=
μ
ℜ=4385.81
fi=0.4924 ℜ−0.2741
fi=0.4924 (4385.81)−0.2741
fi=0.04943
Pt =1.25 Do
Pt =1.25(0.01905)
Pt =0.02381
C ' =Pt−Do
BC ' Ds
As=
Pt
As=0.0182m 2
m
Gs=
As
57301.66 Kg/hr
Gs=
0.0182 m2
Gs=3148442.857
1.09 Pt 2
De= −Do
Do
1.09(0.02381 m)2
De= −0.01905 m
0.01905 m
De=0.01338m
fiNpL v 2 ρ
ΔPi=
2 gcDi
kg
ΔPi=44.45 2
=0.0044 kg/cm 2
m
DeGs
ℜ=
μ
( 0.01338m ) (3148442.857)
ℜ=
2.7513 kg /mhr
ℜ=15311.36
fo=1.775 ℜ−0.1947
fo=1.775(15311.36)−0.1947
fo=¿ 0.2718
L
fo Gs2
Ds
B
ΔPo=
2 ρgcDe
ΔPo=
( 0.2718 ) ( 3148442.857 )2 ( 1.829 m
0.127 m )
(0.5398 m)
kg
ΔPo=6,195.08 2
=0.61950 kg /cm2
m
ΔPtotal=0.0044+0.61950
ΔPtotal=0.6239 kg/cm 2
Cálculo de caídas de presión con el agua de enfriamiento fluyendo por los tubos:
mc
v=
Af ρc
57301.66 Kg/hr
v=
( 0.02609 m2 ) (994.825 kg/m3)
v=2207.73 m/hr
Divρ
ℜ=
μ
ℜ=11840.872
fi=0.4924 ℜ−0.2741
fi=0.4924 (11840.872)−0.2741
fi=0.0376
fiNpL v 2 ρ
ΔPi=
2 gcDi
27216 kg /hr
Gs=
0.0182 m2
Gs=1495384.61
DeGs
ℜ=
μ
( 0.01338m ) (1495384.61)
ℜ=
3.528 kg /mhr
ℜ=5,671.27
fo=1.775 ℜ−0.1947
fo=1.775(5671.27)−0.1947
fo=0.32988
L
fo Gs2
Ds
B
ΔPo=
2 ρgcDe
1.829 m
ΔPo=
( 0.32988 )( 1495384.61 )2 ( 0.127 m)(0.5398 m)
ΔPtotal=0.0177+0.1436
ΔPtotal=0.1613 kg/cm 2
La menor caída de presión como se puede observar la obtenemos haciendo circular el agua
fría por dentro de los tubos.
10. Se desea calentar 3000 kg/hr de alcohol etílico desde 10 a 60°C usando agua caliente
que pasará de 90 a 65 °C. Se permitirán 0.7 kg/cm² de caída de presión en cada corriente.
Para este servicio se tienen tubos de acero de ¾ de plg, 13 BWG, de 2 m. de largo. Se
requiere una velocidad en los tubos cercana a 1 m/seg.
Datos:
Di = 0.014224 m
Do = 0.01905 m
xw = 0.002413
mc = 3000 kg/h
Tca = 10 C
Tcb = 60 C
µc = 3.24 kg/mhr
kc = 0.15624 Kcal/mhrºC
ρc = 785.22 kg/m3
Tha = 90 C
Thb = 65 C
µh = 1.3302 kg/mhr
kh = 0.589 Kcal/mhrºC
ρh = 973.3 kg/m3
Qg=mc Cpc ∆ T c
mh=Qg/( Cph ∆ T h )
mh = 3710.72 Kcal/hr
m
Af =
vρ
3710.72 kg/hr
Af =
(3600 m/hr ) ( 973.3 kg/m 3)
Af =1.0590 ×10−3 m 2
Nt Af
=
Np π 2
Di
4
Nt 1.0590 ×10−3 m2
=
Np π
(0.014224)2
4
Nt
=6.66
Np
Suponemos 4 pasos:
Nt=6.66(4 )
Nt=26
π 2 Nt
Af = Di
4 Np
π 26
Af = (0.014224)2
4 4
Af =1.03287 ×10−3 m2
mh
v=
Af ρh
3710.72 kg/hr
v=
(1.03287 ×10−3 m 2)( 973.3 kg/m3 )
v=3691.17 m/hr
Divρ
ℜ=
μ
m
ℜ=
( 3691.17 ) ( 0.014224 m) (973.3 kg/m )
h
3
1.3302 kg/mhr
ℜ=38416.36
k 0.8 0.33
hi=0.023 ℜ Pr ϕ
Di
0.33
.589 Kcal /mhr ° C ( 1.0025 ) (1.3702)
hi=0.023
0.014224
(38416.36)0.8 ( 0.589 ) ϕ
hi=5801.58 ϕi
Ds = 0.2032 m
Pt = 0.0238125 m
1.09 Pt 2
De= −Do
Do
1.09(0.0238125)2
De= −0.01905
0.01905
De=0.01339m
C’ = 0.0104179m
Ds
B=
5
0.2032
B=
5
B=0.04064 m
BC ' Ds
As=
Pt
As=3.6128 ×10−3 m2
m
Gs=
As
3000 kg/hr
Gs=
3.6128 ×10−3 m 2
Gs=830364.28 kg/hr m 2
0.55 0.33
k DeGs Cpμ
ho=0.36
D μ ( ) ( ) k
ϕo
0.55 0.33
0.15624 ( 0.01339 ) (830364.28) ( 0.62 ) (3.24)
ho=0.36 ( 0.01339 )( 3.24 ) ( 0.15624 ) ϕo
ho=858.73 ϕo
77.5+35
Tws=
2
Tws=56.25 ºC
µwagua = 1.79 kg/mhr
ϕi=0.95
.14
μ
ϕo= o
μw ( )
.14
3.24
ϕo= ( )
2.34
ϕo=1.04
5511.5
Twc=77.5−(77.5−35)
898.75+5511.75
Twc=40.95 ° C
0.14
1.33
ϕi= ( )
2.35
ϕi=0.92
0.14
3.24
ϕo= ( )
3.06
ϕo=1.00
hi=( 5801 ) (0.92)
Twc=40.93 ° C
( Do−Di)
D ml=
Do
ln ( )
Di
(0.01905−0.014224)
Dml=
0.01905
ln ( )
Di 0.014224
D ml=0.0165196 m
xwDo
Rw=
KwDml
( 0.002414 ) (0.01905)
Rw=
( 38.66 ) ¿¿
1
Uo=
Ri+ Ro+ Rw + Rdi+ Rdo
1
Uo=
0.01905 1
+7.1976 ×10−5+ +7.68 ×10−4 +2.04 ×10−4
(5336.92 ) (0.014224 ) 858.73
( Tha−Tcb )−(Thb−Tca)
ΔT ml=
Tha−Tcb
ln ( )
Thb−Tca
( 90−60 )−(65−10)
ΔT ml=
90−60
ln( )
65−10
ΔT ml=41.24 ° C
Tha−Thb
R=
Tcb−Tca
90−65
R=
60−10
R=0.5
Tcb−Tca
S=
Tha−Tca
60−10
S=
90−10
S=0.625
fi=0.4924 ℜ−0.2741
fi=0.4924 (38416.36)−0.2741
fi=0.02727
fiNpL v 2 ρ
ΔPi=
2 gcDi
DeGs
ℜ=
μ
( 0.01339 ) (830364.28)
ℜ=
3.24
ℜ=3431
fo=1.775 ℜ−0.1947
fo=1.775(3431)−0.1947
fo=0.3637
L
fo Gs2
Ds
B
ΔPo=
2 ρgcDe
2
( 0.3637 ) ( 830364.28 )2 (0.2032)
0.04064
ΔPo=
2 ( 9.8 ) ( 0.01339 )( 780.22 ) (3600)2
ΔPtotal=0.08+0.093
ΔPtotal=0.1710 kg/cm2
Cálculo de caídas de presión con el alcohol etílico por dentro de los tubos:
m
Gs=
As
3710.72 kg/hr
Gs=
3.6128 ×10−3 m 2
Kg/hr
Gs=1027103.63
m2
4 mNp
ℜ=
πDiμNt
4 ( 3000 ) ( 4 )
ℜ=
π ( 0.014224 )(3.2426)
ℜ=12751.2
Reμ
v=
Diρ
(12751.2 ) (3.24 )
v=
( 0.014224 ) (785.22)
v=3698.98 m/hr
fi=0.4924 ℜ−0.2741
fi=0.4924 (12751.2)−0.2741
fi=0.03689
fiNpL v 2 ρ
ΔPi=
2 gcDi
DeGs
ℜ=
μ
( 0.01339 ) (1027103.63)
ℜ=
3.24
ℜ=10340
fo=1.775(10340)−0.1947
fo=0.2934
L
fo Gs2
Ds
B
ΔPo=
2 ρgcDe
ΔPtotal=0.18 kg/cm 2
11. En una planta se deben enfriar 8112 kg/hr de aguas de desecho, desde 100 °C hasta 45
°C, utilizando agua de enfriamiento limpia, que entrará a 32 °C y saldrá a 38°C. La presión
total de trabajo es de 1.2 kg/cm² abs.
Datos:
Di = 0.014833 m
Do = 0.01905 m
xw = 0.002108 m
Arreglo cuadrado
mh = 8112 kg/hr
Tha = 100 C
Thb = 45 C
µh = 1.42 kg/mhr
kh = 0.583 Kcal/mhrºC
ρh = 976.3 kg/m3
Tca = 32 C
Tcb = 38 C
µc = 2.61 kg/mhr
kc = 0.5365 Kcal/mhrºC
ρc = 993.95 kg/m3
Qc=mh×Cph × ∆Th
Qc = 44829.24 Kcal/hr
mc = 74572.2 Kcal/hr
mc
Af =
v ρc
74572.2
Af =
(10800 ) (993.95)
Af =6.946 ×10−3 m 2
Af Nt
=
π 2 Np
Di
4
6.946 ×10−3 m2 Nt
=
π 2 Np
(0.014833)
4
Nt
=40.20
Np
Suponemos 2 pasos:
Nt=40.20(2)
Nt=80.40
π 2 Nt
Af = Di
4 Np
π 76
Af = (0.014833)2
4 2
Af =6.5664 ×10−3 m2
mc
v=
Af ρc
74572.2 Kg/hr
v=
¿¿
v=11425.65 m/hr=3.17 m/ s
4 mLNp
ℜ=
πDiμNt
4 ( 74572.2 )(2)
ℜ=
π ( 0.014833 ) ( 2.61 ) (76)
ℜ=64540.74
k 0.8 0.33
hi=0.023 ℜ Pr ϕi
Di
0.33
0.5365 Kcal/mhr ° C ( 0.99865 ) (2.61)
hi=0.023
0.014833
(64540.74 )0.8 ( 0.5365 ) ϕi
hi=9873.59 ϕi
Pt =1.25 Do
Pt =1.25(0.01905)
Pt =0.0238125 m
1.27 Pt 2
De= −Do
Do
1.27( 0.0238125)2
De= −0.01905
0.01905
De=0.018752m
C ' =Pt−Do
C ' =0.0238125−0.01905
Ds
B=
3.5
0.3048
B=
3.5
B=0.0870 m
BC ' Ds
As=
Pt
As=5.3087 × 10−3 m2
m
Gs=
As
8112 kg /hr
Gs=
5.3087 ×10−3 m 2
Gs=1528044.72 kg /m2 hr
0.55 0.33
k DeGs Cpμ
ho=0.36
D μ ( ) ( ) k
ϕo
0.55 0.33
0.583 ( 0.0180752 ) (1528044.72) (1.0015 ) (1.42)
ho=0.36 ( 0.018752 )( 1.4202 ) ( 0.583 ) ϕo
ho=3502.52 ϕo
Thprom+Tcprom
Tws=
2
72.5+35
Tws=
2
Tws=53.75 ºC
.14
2.61
ϕi= ( )
1.86
ϕi=1.048
.14
μo
ϕo= ( )
μw
.14
1.42
ϕo= ( )
1.86
ϕo=0.962
Twc=44.21° C
.14
2.61
ϕi= ( )
2.19
ϕi=1.02
.14
μo
ϕo=
μw( )
.14
1.42
ϕi= ( )
2.19
ϕi=0.94
Kcal
hi=10071.06
hr m2 ° C
Kcal
ho=3296.39
hr m 2 ° C
10071.06
Twc=72.5−(72.5−35)
10071.06+3296.39
Twc=44.24 ° C
Kcal
hi=10071.06
hr m2 ° C
Kcal
ho=3296.39
h rm2 ° C
(Do−Di)
Dml=
Do
ln ( )
Di
(0.01905−0.014833)
Dml=
0.01905
ln ( )
0.014833
Dml=0.01685 m
xwDo
Rw=
KwDml
( 0.002108 ) (0.01905)
Rw=
( 333 ) (0.01685)
hr ° C
Rw=7.156 × 10−6
Kcal
1
Uo=
Ri+ Ro+ Rw + Rdi+ Rdo
1
Uo=
0.01905 1
+7.156 ×10−6+ +7.88 ×10−4 +3.07 ×10−4
(10071.06 ) (0.014833) 3296.39
Kcal
Uo=652.29
hr m2 ° C
( Tha−Tcb )−(Thb−Tca)
ΔTml=
Tha−Tcb
ln( )
Thb−Tca
( 100−38 )−(45−32)
ΔTml=
100−38
ln( )
45−32
ΔTml=31.36 ° C
Tha−Thb
R=
Tcb−Tca
100−45
R=
38−32
R=9.16
Tcb−Tca
S=
Tha−Tca
38−32
S=
100−32
S=0.088
ft=0.93
Q
Ao=
UoΔTmlFt
446829.24
Ao=
( 652.29 ) (31.36 ) (0.93)
Ao=23.48 m2
Ao=πDoLNt
23.48
L=
π ( 0.01905 ) (76)
L=5.16 m
fi=0.4924 ℜ−0.2741
fi=0.4924 (64540.74)−0.2741
fi=0.02365
DeGs
ℜ=
μ
( 0.018725 ) (1528044.72)
ℜ=
1.442
ℜ=20149.74
fo=1.775 ℜ−0.1947
fo=1.775(20149.74)−0.1947
fo=0.257
L 5.16
= =59.31
B 0.0870
fiNpL v 2 ρ
ΔPi=
2 gcDi
kg
ΔPi=8405.18 2
=0.840 kg f / cm2
m
L
fo Gs2
Ds
B
ΔPo=
2 ρgcDe
kg
ΔPo=2339.2 2
=0.233 kg f /cm2
m
ΔPtotal=0.840+0.233
ΔPtotal=1.1kg f /cm2
12. Un intercambiador 1-2 recupera calor de 4536 kg/hr de la purga de una caldera a
94914 kg/m2 calentando agua cruda de 21 a 36 ºC. El agua cruda fluye dentro de los tubos.
Se dispone para este servicio de un intercambiador 1-2 de 0.254 m Ds que tiene 52 tubos de
3/4 plg Do, 16 BWG y 2.4384 m de largo. Los deflectores están colocados a 0.0508 m, el
haz de tubos se arregla para dos pasos. ¿Cuáles son las caídas de presión?
Do = 0.01905 m
BWG 16
Xw =1.651x10-3 m
Np=2
Nt=52
TCb = 36 °C
TCa = 21 °C
= 996.075 kg/m3
agua(fluido caliente)
Tv =179.342°C
Mv =4536 kg/hr
P=94914 kg/m2
= 888.54 kg/m3
Balance de calor
π D i Nt 2
Af = =0.005064 m
4 Np
mc 145970.48
v= = =28917.76 m/hr
Af ρc ( 0.005064 ) (996.075)
f i v i 2 N pLi
P i=
2 gcD i
f o G s 2 ( N +1 ) DI
P o=
2 gcDe o
con Reo =151563.8726 fo = 1.775(Reo)-0.1947
fi = 1.775(151563.8726)-0.1947=0.17399
De = (1.09PT2/Do)-Do
De = 0.013387 m
GS = mo/AS
BDiC ’
A s=
Pt
Di = 0.254m
PT = 0.02381 m
C’ = PT – Do = 0.0047625 m
As=2.5809 ×10−3 m2
4536 kg /hr
Gs= −3 2
=1757518.98 kg/ m2 hr
2.5809 ×10 m
ΔPo=0.2166381 kg f /cm2
13. Calcule el tamaño que debe tener un cambiador de calor 1-2 requerido para enfriar
68000 kg/hr de etilenglicol de 121 a 104 ºC usando tolueno como liquido enfriante. El
tolueno se calienta desde 27 hasta 63 °C, use tubos de acero de ¾ de plg 14 BWG con 8
pies de longitud y arreglo triangular de 1 plg de espaciado. La carcasa tendrá manparas con
25 % de corte espaciadas 6 plg. El etilenglicol debe fluir por los tubos por ser el más
corrosivo.
Do = 0.01905 m
BWG14
Xw =2.1082x10-3 m
Dw = 0.023228 m
PT = 1 plg = 0.0254 m
Arreglo triangular
TCb = 63 °C
TCa = 27 °C
= 861.4 kg/m3
k = 0.126976 Kcal/hrmºC
Cp = 0.43 Kcal/kgºC
Etilenglicol (fluido caliente)
mh = mo =68000 kg/hr
Tha = 121 °C
Thb = 104 °C
= 987.1 kg/m3
= 1.4x10-3 kg/ms
k = 0.227664 Kcal/hrmºC
Cp = 0.68 Kcal/kgºC
Balance de calor
786080
mC = =5078.36 kg /hr
( 0.43 ) ( 63 – 27 )
Factor de corrección
121−104 63−27
R= =0.47 S= =0.38
63−127 121−27
Af tot Nt 0.0159 m 2
= = =92.44
Af tub Np 1.72 x 10−4 m2
Nt=(92.44)(2)=184.88
( 0.682 ) (5.04)
Pri= =15.05
0.227664
0.2276
h i=0.023 ( 0.014833 )(11817.90) 0.8
(15.05)0.33 φ i
hi = 1564.63 Фi Kcal/hrm2ºC
KO DeGs 0.55
ho=0.36 ( )(
De µ0 ) 0.33
Pr o φ o
mo
G s=
As
BDsC ’
A s=
PT
C’ = PT – Do = 6.35x10-3 m
B = 0.1584m Ds = 0.43815
5078.36
Gs= =3040740.12 kg /m2 s
( 0.0967 )( 3600)
De = 0.01786 m
Th+Tc 45+112.5
Tw= = =78.75° C
2 2
µw @ Twp
µwi=3.5x10-3 kg/ms
µwo=0.34x10-3 kg/ms
0.14
1.4 x 10−3
hi=1564.63 (
3.5 x 10−3 )
hi=1361.22 Kcal/hrm2°C
0.14
0.55 x 10−3
ho=1325.65 (
0.34 x 10−3 )
ho=71405.18 Kcal/hrm2°C
hi
Twc=Th− ( hi+ho )( Th−Tc )
1405.18
Twc=112.5− ( 1361.22+1405.18 )( 112.5−45)=78.21 ° C
como Tw y Twc son casi iguales ya no se itera.
1
Uo=
Do 1 XwDo
+ +
hi Di h o KwDm
1 1
Ro= = =7.11 x 10−4
ho 1405.8
Do 0.01905
Ri= = =9.43 x 10−4
hiDi ( 1361.22 )( 0.014833 )
Qg 786080
Ao= = =20.52 m 2
Uo ∆Tm ( 582.88 )( 65.69 )
Ao = πDo L NT
Ao 20.52 m2
Nt= = =141.09≠ 196
π Do L π ( 0.0 1905 m ) (2.43 m)
mi 68000 kg/hr
v= = =1.6
Af ρi ( 0.01196 m2 ) (987.1 kg/m3 )
π 2 Nt π 138
Af = Di = (0.0 14833 m)2 =0.0119
4 Np 4 2
m
ℜ=
¿ ρi
=
( 0.014833 m ) 1.6( s )
(987.1 kg/m3)
=16733.31
μi 1.4 x 10−3 kg/ms
h i=0.027 ( 0.227664
0.014833 )
(1 16733.31) 0.8
(15.05)0.33 φi
hi=2066.54 φi
mo
Gs=
As
−3
BDsc´ ( 0.1524 m) ( 0.37735 m ) ( 6.35 x 10 m)
As= = =0.0147
Pt 0.0245 m
507 80 .3 6
Gs= =3454446.25
0.01 47
De=0.01786
0.55
0.126976 ( 0.0178 6 m ) ( 3454446.25)
h o=0.36 (
0.0178 6 )( 1.98 ) (1.87)0.33 φo
ho= 931.81Фo
0.14
1.4 x 1 0−3
hi=2066.54 ( 3.66 x 10−4 )
hi=2493.53 Kcal/hrm2°C
0.14
0.55 x 10−3
ho=931.81 (
0.366 x 10−3 )
ho=986.48 Kcal/hrm2°C
1
Uo= =589.35
1 −5 0.01905
+6.16 x 10 +
986.48 ( 2066.54 ) (0.014833)
Qg 786080
Ao= = =20.3 m2
Uo ∆Tm ( 589.35 )( 65.69 )
20.3m 2
Nt= =139.58
π ( 0.0 1905m ) (2.43 m)
Di = 0.014833m
Do = 0.01905 m
BWG14
Xw =2.1082x10-3 m
Dw = 0.023228 m
PT = 1 plg .0254 m
Arreglo Triangular
TCb = 80 °C
TCa = 68 °C
k = 0.193 Kcal/hrm°C
Cp = 0.75 Kcal/kg°C
mh = mo =35543 kg/hr
Tha = 95 °C
Thb = 82 °C
Para el isobutano
= 444.48 kg/m3
= 0.1x10-3 kg/mseg
k = 0.145 Kcal/hrmºC
Cp = 0.91 4Kcal/kgºC
Balance de calor
420473.69
mC =
( .75 ) ( 80 – 68 )
mC = mi = 46719.29 kg/hr
Factor de corrección
95−82 80−68
R= =1.083 S= =0.44
80−68 95−68
178
(
Áreade flujo= 1.73 x 10−4 ×
4 )
=0.00769 m2
mi 46719.29
v i ( corregida ) = = =3.87 m/s
A f i ( 0.00769 ) ( 444.48 ) ( 3600 )
mo
Gs=
AS
BDsC ’
A s=
PT
Ds = 0.48815 m
PT = 1 plg = 0.0254 m
C’ = PT – Do = 6.35x10-3 m
35543
Gs= =591.43 kg /m2 s
( 0.01669 ) (3600)
DeGs ( 0.024 ) (591.43)
Reo= = =118286
μo 1.2× 10−3
Q = UoAoTmFT
f i v i 2 N pLi
P i=
2 gcD i
La caída de presión dentro de los tubos está dentro del valor permitido.
f o G s 2 ( N +1 ) DI
P o=
2 gDe❑o
De = 0.024 m
ΔPo=0.059 kg f /cm2
15. En una planta de proceso se deben enfriar 308710 kg/hr de condensados desde 91
hasta 86 °C por medio de agua de enfriamiento limpia que entrara a 32 °C y saldrá a 40 °C.
Diseñe el cambiador de calor apropiado.
Agua de Enfriamiento
Tca=32°C
Tcb=40°C
Tcm=36°C
μ=.727x10-3 kg/ms
Cp=0.99865 Kcal/kg°C
ρ=993.95 kg/m3
Pr=4.88
Tha=91°C
Thb=86°C
Thm=88.5°C
μ=.323x10-3 kg/ms
Cp=1.0047 Kcal/kg°C
ρ=966.27 kg/m3
Pr=1.942
1550804.6
mC = =194112.6 kg/hr
( 0.99865 ) ( 40 – 32 )
∆Tm=52.48°C
Arreglo triangular
BWG=14
Do = 0.0254m
Di=0.021183m
Xw=0.0021085m
Dm=0.02322m
Rdo=7.68x10-4 m2hr°C/Kcal
Suponiendo que los condensados van por dentro de los tubos , se propone una velocidad de
1.35 m/s y 4 pasos.
194112.6
Af = =0.0431m 2
( 996.27 ) ( 1.35 ) (3600)
Af Np ( 0.063 ) (2)
Nt= = =58.49
π π
()
4
Di 2
()
4
(0.01656) 2
Af tubo= ( π4 ) Di =3.52× 10
2 −3
m2
Nt 0.0413
= =117.19
Np 3.524 ×10−4
Nt= (117.19)(4)= 469 tubos. En las tablas se encuentra un Nt= 470 Ds= 33”
h i=0.023 ( Dk )( ℜ) 0.8
( Pr)0.33
0.6022
h i=0.023 ( 0.021183 )(85359.3) 0.8
(1.942)0.33
hi=7164.28 Kcal/hrm2ºC
0.55 0.33
ko De Gs Cp0 μ 0
h o=0.36
De ( )( μ0 ) ( ko )
mo
G s=
As
BDsC ’
A s=
PT
Ds = 33 plg = 0.8382 m
PT = 0.03175 m
C’ = PT – Do = 6.35x10-3 m
De=0.0250 m
0.8382
B= =0.16764 m
5
194112.6
Gs= =6907921.7
0.02810
0.55 0.33
0.5365 ( 0.0250 ) (6907921.7) ( 2.617 ) (0.99865)
h o=0.36 ( 0.0250 )( 2.617 ) ( 0.5365 )
ho=5828.58 Kcal/hrm2ºC
0.0254
Ri= =1.673× 10−4 hr m2 ° C /Kcal
( 7164.28 ) (0.021183)
1
Ro= =1.7756 ×10−4 hr m2 ° C / Kcal
( 5828.58 )
1
Uo=
1.673 ×10 +6.924 × 10 +1.7756 ×10−4 +3.07 ×10−4 +7.68 ×10−4
−4 −6
Uo = 700.87 Kcal/hrm2ºC
Q
Ao= =42.28 m 2
Uo ∆Tmft
42.28
L= =1.12m
π ( 0.0254 m )( 470 )
f i v i 2 N pLi 2
P i= =0.0414 kg f /cm
2 gcD i
L
N +1= =6.680
B
f o G s 2 ( N +1 ) D I 2
P o= =0.865 kg f /cm
2 gcDe o
Etanol
30,000 kg/hr
Tca=20°C
Tcb=45°C
Tcm=32.5°C
μ=1.75x10-3 kg/ms
Cp=0.65 Kcal/kg°C
ρ=786kg/m3
Tha=80°C
Thb=45°C
Thm=62.5°C
μ=.454x10-3 kg/ms
Cp=1.00025Kcal/kg°C
ρ=982kg/m3
487500
magua = =13893.83 kg /hr
( 1.00025 ) ( 35 )
∆Tm=29.72°C
Arreglo triangular
BWG=14
Do= 3 / 4 in = 0.01905m
Di=0.014833m
Xw=0.0021085m
Dm=0.016854m
30000
Af = =0.014 m 2
( 0.0136 ) (786)
( 0.014 ) (4)
Nt= =324
π
()
4
(0.014833)2
Ds = 21 ¼
Af = ( π4 )(0.014833) 3144 =0.0136 m
2 2
30000
v= =2814=0.78 m/s
( 0.0136 )( 786 )
0.15624
h i=0.027 ( 0.014833 )(5130) 0.8
(26.21)0.33 φi
hi=776.43 φ i
Pt=0.0238125m
De=0.0134m
Ds=0.53975m
0.53975
B= =0.108 m
5
C’=0.0047625
3.8 kg/ s
Gs= 2
=329.91 kg/m 2 s
0.017 m
0.55
57025 ( 0.0134 ) (330)
h o=0.36 ( 0.0 134 )( 0.454 ×10−3 ) (2.87)0.33 φo
h o=3389.02 φo
Twp=56.64
µw @ Twp
µwi=1.35x10-3 kg/ms
µwo=0.4965x10-3 kg/ms
0.14
1.75 x 1 0−3
hi=776.43 (
1.35 x 10−3 )
hi=779.72 Kcal/hrm2°C
0.14
0.454 x 10−3
ho=3389.02 ( 0.4965 x 10−3 )
ho=3355.02 Kcal/hrm2°C
779.72
Twc=62.5− ( 3355.02+779.72 ) ( 62.5−32.5 )=56.86 ° C
1
Ro= =2.98 x 10−4
3355.02
0.01905
Ri= =1.65 x 10−4
( 779.72 ) ( 0.014833 )
Rw=7.16 x 10−5
1 Kcal
Uo= =405.48
hr m 2 ° C
−4 −4
−5 −4 −4
3.07 x 10 +1.65 x 10 +7.16 x 10 +2.98 x 10 +2.04 x 10
487500 2
Ao= =51.2 m
( 405 .48 ) ( 29.72 ) (0.79)
Ao 51.2
L= = =2.72 m
πDoNt π ( 0.01905 ) (314)
f i v i 2 N pLi 2
P i= =0.0084 kg f /cm
2 gcD i
L
N +1= =25.18
B
f o G s 2 ( N +1 ) D I 2
P o= =0.2 kg f /cm
2 gcDe o
Pt otal=Pi+ P o=0.2084 kg f /cm2
17. 27250 kg/hr de queroseno de 42 °API se enfrian de 204 a 107 °C calentando un
destilado de 35 °API de 37 a 93 °C.
Use tubos de ¾ de plg de Do, 16 BWG de 16 pies de longitud y arreglo triangular de 15/16
plg de espaciado. Se permite una caida de presión de 10 lb/plg 2 en cada corriente,
seleccione el intercambiador más adecuado.
Destilado
Tcb = 93 °C
Tca = 37 °C
= 804.01 kg/m3
k = 0.1466 Kcal/hrmºC
Cp = 0.5 Kcal/kgºC
Queroseno
mh =50000 kg/hr
Tha = 204 °C
Thb = 107 °C
= 656.58 kg/m3
= 0.95x10-3 kg/mseg
k = 0.14288 Kcal/hrmºC
Cp = 0.62 Kcal/kgºC
Q=mh Cph (T ha – T hb )=mC Cpc ( T Cb – T Ca )
m C =1638815/(0.5)(93−37)
mC = 58529.1 kg/hr
( 204−93 ) −(107−37)
∆ Tm= =89 ° C
( 204−93)
ln
(107−37)
Propuesta: Si el destilado va por el interior de los tubos y si se usa una velocidad de diseño
de 0.32 m/seg.
m
Af =
v
58529
Af = =.06319 m 2
( 0.32 )( 804 )( 3600 )
( 0.01575m )2 ( 692 )
Af new = =0.06739 m2
4 2
m
v c=
Af
58529
v c= =0.3 m/s
(0.06739)(804)
D vc ρ
ℜ= =( 0.3 )( 804 ) ¿ ¿
μ
k 0.8 0.33
hi=0.027 ℜ Pr ϕi
Di
0.1466
hi=0.027 (723.6)0.8 ( 64.46 )0.33 ϕi
0.01575
BC ' Ds
As=
Pt
m
Gs=
As
Ds = 29 plg = 0.7366 m
PT = 0.02381 m
C’ = PT – Do = 4.763x10-3 m
Ds
Propuesta, B= =0.14732 m
5
27250
Gs= =348.8 kg /m2 s
( 0.0217 )( 3600)
Cp o ❑o
Pr= ( ko )
=14.84
0.1429
h o=0.36 ( 0.01339 )( 4916.24 ) 0.55
( 14.84 )0.33
ho = 1003.52 Kcal/hrm2 ºC
Tw propuesta= 82°C
−3
μw =1 .6 x 10 kg/ms para el lado interno de los tubos
3
μw =0 . 8 x 10− 3 kg/ms para el lado de la coraza
φi=1.181 φo=1.024
1027
Twc=155.55−(155.55−65)
1027+227.8
Twc=81.43 °C
Twc=81.48 °C
−3
Rdo = 12.29x10 hrm2ºC/Kcal
−3
Rdi =12.29x10 hrm2ºC/Kcal
1
Uo=
5.24 ×10 + 9.64 ×10 +12.29 ×10−3+12.29 ×10−3 +5.44 ×10−6
−3 −4
Uo = 151.1 Kcal/hrm2ºC
Q
Ao= =122 m 2
UoΔTmFt
fiNpL v 2 ρ 2
ΔPi= =0.01851 kg f /cm
2 gcDi
L
fo Gs2
Ds
B
ΔPo= =0.583 kg f /cm2
2 ρgcDe
18. 38000 kg/hr de queroseno de 42 °API se enfrian de 98 a 38 °C calentando agua de 30 a
48 °C.
Use tubos de ¾ de plg de Do, 16 BWG de 16 pies de longitud y arreglo triangular de 1 plg
de espaciado. Se permite una caída de presión de 10 lb/plg 2 en cada corriente, seleccione
el intercambiador más adecuado. Se propuso una vel max permitida en diseño de
intercambiadores de calor de 2 m/s se propuso Ds para poder saber el Np y el Nt los cuales
se iteraron conforme a la tabla del apendice 18 del manual de tablas facilitado por el
profesor
Tha=98°C
Thb=38°C
Tca=30°C
Tcb=48°C
L=( 16 ) (0.3048)
Do=0.01905m
Di=0.015748m
Pt=0.0254m
Gc=9.8 m/s2
v=2m/s
( Tha−Tcb )−(Thb−Tca)
∆ Tm=
(Tha−Tcb)
ln
(Thb−Tca)
Qc=m s Cp k ( T ha – T hb )
Qg=mi Cpa ( Tc b – Tc a )
Ds=8 in
0.3048
Ds 1=Ds ( 12 )
38000
ms =
3600
k =(0.78)(912.98)
k = 0.95x10-3
Ds1
B=
5
C’ = PT – Do
L
N= −1
B
mo
Gs=
AS
BDsC ’
A s=
PT
DeGs
ℜ=
μk
fo = 1.775(Rei)-0.1947
De = (1.09PT2/Do)-Do
f o G s 2 ( N +1 ) Ds 1
P o=
2 gcDe ❑k 10000
14.7
P o¿ =P o
1.033
Np=1
a =992.55
a = 0.6686x10-3
Cpk=0.52
Cpa=0.9869
Ft=0.9378
Divi ρa
ℜi =
μa
fi = 0.492(Rei)-0.2741
f i v i2 N pL i
P i=
2 gcD i10000
14.7
P i¿ =Pi
1.033
mi
Af =
v iρi
π D i Nt
Af =
4 Np
Ao=πDoLNt
Q
Uo=
Ao Tm Ft
Np=6
Ao=82,98m2
Uo=665kcal/m2°Cs
∆Pi=13,48Lb/in2
∆Po=11,3Lb/in2
Ds=25In"
19. En el proceso de lavado de las botellas de cerveza se requiere agua limpia y tratada
químicamente, a 60 °C; el agua del lavado se vierte por el drenaje a 55 °C. Actualmente se
usa un calentador eléctrico para calentar esta agua, cuya temperatura inicial es de 30 °C y el
suministro requerido es de 50000 kg/hr. La planta opera 24 hrs por día, 313 días por año, y
el costo de la electricidad es de 8 centavos el Kwhr. Con objeto de ahorrar energía, se
propone instalar un intercambiador de calor de carcasa y tubos para calentar esta agua. Se
utilizará agua de desecho proveniente de otro proceso, con una temperatura de 90 °C
enfriándose hasta 62 °C. Para reducir los costos de operación, la caída de presión debe ser
menor a 0.3 kg/cm2 para cada corriente.
Tca=30 ºC
Tcb=60 ºC
Tha=90 ºC
Thb=62 ºC
mc=50000 kg/hr
P1=101
gc=9,8
Balance de energía
Q g=mC Cp C ∆ Tc
∆ Tc=Tcb−Tca
∆ Tc=60−30=30 ° C
Tcb+Tca
Tcm=
2
Tcm=45 ° C
mh= (1.498x106)/(1.001)(28)
∆ Tc=Tha−Thb
∆ Th=90−62=28 ° C
Thb+ Tha
Thm=
2
Thm=76 ° C
( Tha−Tcb )−(Thb−Tca)
∆ Tm=
(Tha−Tcb)
ln
(Thb−Tca)
( 90−60 )−(62−30)
∆ Tm= =30.99 ° C
( 90−60)
ln
(62−30)
Tha−Thb
R=
Tcb−Tca
R = 0.9333
Tcb−Tca
S=
Tha−Tca
S = 0.5
1−S
Ft =
0.5
( R 2+1 ) ln [
1−(S R) ]
( R−1 ) ln ¿ ¿
Ft = 0.8316
∆ Tmc=∆ Tm Ft
i = 0.373x10-3 kg/m
ki = 0.5621 Kcal/hrmºC
Cpi = 1.001Kcal/kgºC
k 0.8 0.33
hi=0.023 ℜ Pr ϕi
Di
ϕ i=0.9702
0.5621
hi=0.023 ( 42045)0.8 ( 2.391 )0.33 =3948 Kcal /hr m 2 ° C
0.0211
¿ ρi
ℜi =
μi
Rei = 42045
Propuestas
v=0.76 m/s
Np = 6
( 1.27 Pt 2 )
De= ( Do )
− Do
Do−Di
Xw =
2
Do−Di
Dm=
Do
ln ( )
Di
B = Ds/3
N+1 = (L/B)
L= 3,66
C’= Pt-Do
Pt=1,25Do
o = 990.2 kg/m3
ko = 0.5369 Kcal/hrmºC
Pro = 3.994
KO DeGs 0.55
ho=0.36 ( )(
De µ0 ) 0.33
Pr o φ o
mo
G s=
As
BDsC ’
A s=
PT
Gs=394.4 kg/m2s
1
Uo=
Do 1
+ + Rw + Rdi+ Rdo
hi Di h o
1
Uo=
1 0.0254
+ + 7.68 x 10−4 + 6.929 x 10−6 +3.07 x 10−4
2644 ( 3948 )( 0.0211836 )
Uo = 566.9 Kcal/hrm2ºC
Qg
Ao=
Uo ∆Tmc
Ao = 102.5 m2
mc
Aft=
v ❑i 3600
Aft = 0.01876 m2
Número de tubos
Ao
Ntc=
π Do L
Ntc = 351.1
Aft
Nt= Np
0.785 Di2
Nt = 319.6
Ds=2.1 Pt Nt 0.42
Ds = 0.7514 m
Caída de presión
fi = 0.492(Rei)-0.2741
fi = 0.0266
f i v i 2 N pL❑i
P i=
2 gcD i10000
fo = 1.775(Reo)-0.1947
fo = 0.2678
f o G s 2 ( N +1 ) DI
P o=
2 gcDe❑o 10000
P t=P o+ Pi
Solución:
Datos: Se usa un cambista de calor de paso de dos cáscaras y paso de cuatro tubos para
calentar aceite. Para el fluido frío, mc = 4540 Kg/h, Cc = 0.4 Kcal/Kg°C, Tc,o = 65.5 °C. El
cambista de calor usa agua caliente a una temperatura de 93.33 °C y a una razón de flujo de
3632 Kg/h. El coeficiente de transferencia de calor total es 463.6 Kcal/hm 2°C. El aceite es
el fluido del tubo.
Física requerida: El calor neto que pierde el agua es igual al calor neto que gana el aceite y
es igual también a la energía calorífica transmitida a través de la superficie de transferencia
de calor.
Ch = 1 Kcal/Kg°C
o bien
Th,o = 68.33 °C
65.5−15.55
P= =0.64
93.33−15.55
93.33−68.33
R= =0.50
65.5−15.55
Además
( 93.33−65.5 )−(68.33−15.55)
∆ Tm= =38.87 ° C
( 93.33−65.5)
ln
( 68.33−15.55)
A = 5.24 m2
21- Considere un intercambiador de calor del tipo de coraza y tubos en donde se tienen dos
pasos de tubos. El área de transferencia de calor es 5 m 2 y se sabe que el coeficiente total
de transferencia de calor es igual a 1032.8 kcal / hr m2 °C. Si a través de los tubos entran
10000 kg / hr de agua a 25 °C mientras que por la parte de la coraza entran 5000 kg / hr de
agua a 90 °C, determine las temperaturas del agua a la salida del intercambiador de calor.
Suponga que el calor específico del agua es igual a 4.18 J / g-mol °K
Solución
C* = 0.5
UA ( 1200 ) (5)
N ut = = =1.03
C min 5805.56
90−T csal
0.54=
90−25
Tc,sal = 54.9 °C
T fsal−T fent
0.54=
T cent −T csal
Sustituyendo valores:
T fsal−25
0.5=
90−54.9
Tf,sal = 42.55 °C
22.- Una laminadora de acero desea enfriar 11.355 m 3/hr de un líquido inorgánico de 121
ºC a 82 ºC mediante agua fluvial, que fluye a través de un cambiador de coraza y tubos
con un gasto de 18.925 m3/hr. El líquido es un poco ácido, y por lo tanto, se requerirá una
aleación especial muy probablemente. Dentro de la planta existe un cambiador con
cabezales flotantes, nuevo y de tipo coraza y tubos, el cual tiene un paso en la coraza y dos
pasos en los tubos. La coraza está hecha de acero común y corriente, en tanto que los tubos
son del tipo 304 de acero inoxidable. Las especificaciones del cambiador en cuestión,
revelan que el diámetro interno de la coraza es de 20 Plg ( 0.508 m ) con 158 tubos de 1
Plg ( 0.0254 m ) y 14 BWG con 4.88 m de largo y sostenidos según un montaje cuadrado
que deja 1 ¼ ( 0.0318 m ) de centro a centro. Los soportes están colocados a 0.1524 m
uno de otro.
( T B 2−T B 1) =¿ ¿
Para estar seguros, la temperatura de entrada del agua de enfriamiento deberá basarse en la
temperatura máxima del agua fluvial, digamos 26.6 ºC. Así que, el agua entrará a ésta
temperatura y saldrá a 50 ºC. Por lo tanto, la Tml a contracorriente verdadera para éste
cambiador es:
( 121.1−50 )−(82.2−26.6)
∆ T mi= =45 ° C
(121.1−50 )
ln
(82.2−26.6)
Para un paso de la coraza, y dos pasos en los tubos, de gráfica se obtiene el factor de
corrección:
FT = 0.97
Tml=(0.97)(45ºC) = 43.3ºC
Di = 0.02118 m
11355 kg /hr
G= 2
=405937 kg/hr m 2
0.02796 m
121.2+ 82.2
T m= =101.6 ° C
2
µ= 0.25 x 10-3 kg / ms
DG ( 0.02118 ) (405937)
N ℜ= = =9550
μ ( 0.25× 10−3 ) (3600)
L 4.8768
= =230
D 0.02118
j = 0.0038
Cp = 1 kcal / kg ºC
k = 0.598 kcal / hr m ºC
−3
Cp μ ( 0.25 ×10 ) (3600)
N Pr= = =1.5
k 0.598
hi Cp μ 2
μ 0.14
j=
CpG k( )( ) 3
μw
=0.0038
En la primera prueba, supongamos que ésa relación de viscocidades es = 1,
así que resolviendo la ecuación anterior por hi , obtenemos
( 0.0038 )( 1 ) (405937) 2
hi = =1177.53 Kcal /hr m ° C
(1.31)(1)
Area de flujo:
1 Plg en los tubos de diámetro externo montados según un cuadrado con distancias de 1 ¼
Plg de centro a centro, dando un claro para el flujo del fluido de 0.25 Plg. El número de
tubos en el centro del cambiador puede calcularse, dividiendo el diámetro de la coraza entre
la distancia entre centros y restándole 1 al número resultante; así que,
Tomando la longitud del área del flujo en el lado de la coraza como igual al espaciamiento
entre los deflectores, el área mínima de flujo para el lado de la coraza se transforma en:
Acoraza=(15)(0.00636)(0.1524)=0.01455 m2
Tm = 38.3 ºC
µ= 0.68 x 10-3 kg / m s
Cp = 1 kcal / kg ºC
k = 0.5215 kcal / hr m ºC
μ
( )
μw
=1
−3
Cp μ ( 0.68 ×10 ) (3600)
N Pr= = =4.7
k 0.5215
( 0.0085 )( 1 ) (1300812)
h o= =3934.84 kcal/hr m2 ° C
( 2.81 ) (1)
Resistencia :
1 1
= =0.0008514 hr m 2 ° C /kcal
hi 1174.53
Tubo:
Ai ( 1 ) (0.0202)
= =0.0003545
ho A o ( 2660.94 ) (0.95)
∆ x Ai
0.0007=
k Am
Resistencia total
1
=0.0013588 hr m2 ° C /kcal
Ui
0.14 0.14
μis 0.5
( ) ( )
μw
=
0.25
=0.958
Ajustando ho
2360.204
h o= =2464.409 kcal/hr m 2 ° C
0.958
0.000851404 ∆ T
= =∆ T =22.2° C
0.0013585 45.5
0.14 0.14
μis 0.45
( ) ( )
μw
=
0.25
=1.085
1171.2
h o= =1079.45 kcal/hr m2 ° C
1.085
1
=0.000926 hr m 2 ° C /kcal
hi
Tubo
∆ x Ai
0.0001434=
kA
1
=0.0014 hr m 2 ° C/ kcal
Ui
U i=714.28 kcal/hr m2 ° C
Q 441515
Ai = = =10.31 m 2
U i ∆ T ML Ft ( 714.28 ) ( 0.97 ) (45.28)
La superficie total:
1 1
Rd= − =0.007092−0.001410=0.005682 hr m 2 ° C
U id U ic
23.- Un cambiador de calor de tipo coraza y tubo que tiene dos pasos en la coraza y 4 pasos
en los tubos, está siendo utilizado como enfriador. El fluido del lado de la coraza entra a
204 ºC y sale a 93 ºC. Y el fluido del lado de los tubos entra a 37.8 ºC y sale a 93 ºC.
¿ Cuál es la diferencia media de temperaturas entre el fluido caliente y el fluido frío ?
∆ T 1−∆ T 2 111−55.2
∆ T mi= = =80 ° C
∆T 1 111
ln ln
∆T 2 52.2
( T A 1 −T A 2 ) ( 204−93 )
Z= = =2
( T B 2−T B 1 ) (93−37.8)
( T B 2−T B 1 )
X= =0.33
( T A 1 −T B 1 )
Ecuación. Q = Uo Ao ?Tm Y
Diferencia de temperaturas.
?T2 = 71 – 30 = 41°C
41−28
T lm=
41
ln
28
Factor Y.
( 71−39 )
Z= =1.68
(30−11)
(30−11 )
X= =0.316
( 71−11 )
Intersección: Y = 0.89
Area.
25200
Ao=
( 26.785 ) (34 ) ( 0.89 )
Ao = 31.09 m²
25.- Calcule el tamaño que debe tener un cambiador 1–2 requerido para enfriar 68 000 kg/h
de etilenglicol de 121 °C a 104 °C usando tolueno como líquido enfriador. El tolueno se
calienta desde 27 °C hasta 63 °C, Use tubos de acero de ¾ de in. 14 BWG con 8 ft de
longitud y arreglo triangular de 1plg. La carcasa tendrá mamparas con 25 % de corte
segmental espaciadas 6 plg. El etilenglicol debe fluir por los tubos por ser el más
corrosivo.
Balance de energía.
Q = UoAoT Y
Cálculos.
Balance de energía.
Diferencia de temperaturas
Factor Y.
(121 – 104 )
Z= =0.472
(63 – 27)
( 63 – 27 )
X= =0.382
(121 – 27 )
Y=0.975
Do = 0.01905 m Di = 0.0148336 m.
L = 2.44 m. Pt = 0.0254 m.
68000 kg /hr
Areatransversal= 3
=0.014488m2
3600 s/hr ( 1.25 m/s ) ( 1043 kg / m )
0.014488
Nt= =83.87 tubos por paso
( 0.785 ) ( 0.0148336)2
68000
Velocidad= =1.07 m/s
(3600) ( 1043 ) (0.0169246)
Coeficiente interno.
A 112.5°C
k = 0.188 kcal/hrm°C
( 0.0148336 m ) (1.07 m/ s ) (1043)
N ℜ= =10477
1.58 x 10−3
hiDi
=0.023 ( 10477 )0.8 ( 20.67 )0.4=126.98
k
hi = 1609 kcal/h.m².°C
Coeficiente de la envolvente.
De = 0.0185 m.
51167
Gs= =851.4 kg/ms
( 0.0166935)(3600)
( 0.0185 ) (851.4)
N ℜ= −3
=35636
0.442 x 10
0.55
Nu=0.36 ( 35636 ) ( 5.386 )1 /3=201
ho = 1374 kcal/hrm°C
Suciedades.
Ao = 24.668 m²
24.668
Nt= =168.92
π ( 0.01905 ) (2.44)
Do = 0.01905 m
BWG14
Xw =2.1082x10-3 m
Dw = 0.023228 m
PT = 1 plg = 0.0254 m
Arreglo triangular
= 861.4 kg/m3
k = 0.126976 Kcal/hrmºC
Cp = 0.43 Kcal/kgºC
Tha = 121 °C
Thb = 104 °C
= 987.1 kg/m3
= 1.4x10-3 kg/mseg
k = 0.227664 Kcal/hrmºC
Cp = 0.68 Kcal/kgºC
Balance de calor
mC = 786080/(0.43)(63 – 27)
mC = mi = 50780.36 kg/hr
( 104−27 ) −( 121−63 )
ΔT m= =67 . 05 ºC
( 104−27 )
Ln
( 121−63 )
Factor de corrección
121−104 63−27
R= =0 . 47 S= =0 .38
63−27 121−27
68000
=0 . 0159 m2
Área por paso = ( 3600 )( 1 .2 ) (987 . 1)
AFtot NT 0 . 0159 m2
= = =92 . 44
AFtubo NP 1. 72 x 10−4 m2
NT=(92.44)(2)=184.88
hi = 0.023(ki/Di)(Rei)0.8(Pr)0.33
Di v i ρi ( 0 . 014833 ) ( 1. 13 ) (987 . 1)
Rei = = =11817. 90
μi 1. 4 x 10−3
( 0 . 682 )( 5 . 04 ) ( 3600 )
Pr i= =15 . 05
0 .227664
hi = 1564.63 Фi Kcal/hrm2ºC
ho = 0.36(ko/De)(DeGS/o)0.55(Cpoo/ko)0.33
GS = mo/AS
AS = (BDsC’)/PT
C’ = PT – Do = 6.35x10-3 m
B = 0.1584m Ds = 0.43815
0 .1524 ( 0. 43815 ) ( 6 . 35 x 10−3 )
As= =0 . 0167 m 2
0 . 0254
50780 . 36
GS = =3040740. 12 kg/m 2 seg
( 0 . 0967 ) (3600 )
De = 0.01786 m
ho = 1325.65 Фi Kcal/hrm2 ºC
Th+Tc 45+112. 5
Tw= = =78 .75 ºC
2 2
0. 14 0. 14
μ 1 . 4 x 10−3
Φi=
( ) (
μw
=
3 .5 x 10−3 ) =0. 87
0 .14 0 .14
μ 0 . 55 x 10−3
Φo=
μw( ) ( =
0 . 34 x 10−3 ) =1. 06
hi = 1564.63(0.87) = 1361.22
ho = 1325.6581.06)= 1405.18
ho
Twc=Th− ( Th−Tc )
hi +ho
1405 . 18
Twc=112. 5− ( 112.5−45 ) =78. 21 ºC
1361 .22+1405 . 18
1
U o=
1 Do
+ Rw+
ho hidi
Ro = 1/ho =1/1405.8=7.11x10-4
Ri = Do/(hiDi) = 0.01905/((1361.22)(0.014833)) =9.43x10 -4
Qg 786080
Ao= = =20 . 52 m2
Uo ΔTm L ( 582 .88 )(65 . 69 )
Ao = Do L NT
Ao 20 .52 m2
NT= = =141 . 09≠196
Π DoL Π (0. 01905 )(2. 43 m)
Π 2 NT Π (138)
Af = Di = (0. 014833 )2 =0 . 0119
4 NP 4 (2)
hi=2066 .54φi
ms
Gs=
As
−3
BDsc ' (0. 1524 m)(0 . 37735 m)(6 .35 x 10 )
As= = =0 .0147
PT 0 . 0245 m
50780 . 36
Gs= =3454446 . 25
0 .0147
De=0 . 01786
0 .55
0.126976 (0 .01786 )(3454446 .25 )
ho=0 .36 ( 0. 01786 )( 1. 98 ) (1 .87 )0 .33 φo
ho=931.81φo
μ
φi= ( )
μω
0 .14
1 .4 x10−3
hi=2066 . 54 (
0 .000366 ) =2493 .53
0.14
0.55 x 10−3
ho=931.81 (
0.000366 ) =986 .48
1
Uo= =589. 35
1 0 . 01905
+6 . 16 x 10−5 +
986 . 48 (2066 .54 )(0 . 014833)
Qy 796080
Ao= = =20 . 3 m2
Uo ΔTm L (589 . 35)(65 . 69)
20 .3 m2
NT= =139. 58
Π (0 .01905)(2 .43 m)
26.- Una solución de 50000 kg/hr de Dietanolamina a 127 ºC se debe enfriar hasta 79
ºC por medio de agua que entra a 32 ºC y sale a 46 ºC. Diseñe un intercambiador de
calor para esto si se usan tubos de 4.88 m de largo de 1 In de diámetro y calibre 14
BWG. Por necesidades de mantenimiento se debe utlizar un arreglo cuadrado con
espaciamiento de 1 ¼ In. Los tubos serán de acero al carbón.
Q = M1 Cp1 ( T1 – T2 ) = M3 Cp3 ( T4 – T3 )
Q = Uo Ao Tml FT
(121 – 79 )
Z= =3.42
(46−32)
( 46−32 )
X= =0.1473
(121 – 32 )
Si el agua va por el interior de los tubos y si se usa una velocidad de diseño de 1.5 m / s.
Di = 0.0211836 m
Do = 0.0254 m
Xw = 2.1082x10-3 m
Dw = 0.023228 m
Tm = 39 ºC
157.234
Área por paso= =0.029116 m2
(3600 ) (1.5)
El arreglo más apropiado será de Ds = 21 In, 2 pasos, 166 tubos en arreglo cuadrado
A 39 ºC
ρ= 995 kg / m3
µ= 0.682 x 10-3 kg / m s
k= 0.5383 kcal / hr m ºC
Cp = 1 kcal / kg ºC
( 156448 ) (2)
Gt = −3
=14865 kg/m2 s
(166) ( 3.5225 x 10 ) (3600)
( 0.0211836 ) (1486.5)
ℜt = =46169.3
0.0682 x 10−3
h = 5776 kcal/hrm2 ºC
Coeficiente externo
Ds = 0.5334 m
Do = 0.0254 m
Pt = 0.03175 m
C = 6.35x10-3 m
Si B = Ds / 2 = 0.2667
De = 0.25146 m
Tm = ( 127 + 74 ) / 2 Tm = 103 ºC
µ= 0.5329 x 10-3 kg / m s
( 0.025146 ) (488)
ℜ= −3
=23476
0.5229 x 10
Pr = 3.685
1
Uo= −3
1 1 ( 0.0254 ) (2.1082 x 10 ) ( 0.0254 ) ( 0.0254 )
+ + + +
3000 2666 ( 37 ) (0.023228) ( 5776 ) (0.0211836) ( 1480 ) (0.0211894 )
∆ Pr ( 1486 )2
=( 4 ) (2) 2
=0.91 kgf m/kg
ρ 2 ( 9.81 ) ( 995 )
∆P
T =0.91+1.358=2.268 kg f m/ kg
ρ
= 970 kg / m3 Gs = 448
( 1.135 ) (970)
∆ P s= =0.11 kg f /cm2
10000
31. Una solución de 50000 kg/hr de Dietanolamina a 127 ºC se debe enfriar hasta 79 ºC por
medio de agua sin tratar, que entra a 32 ºC y sale a 46 ºC. Diseñe un intercambiador de
calor adecuado que permita una caída de presión máxima de 0.25 kg/cm 2 para los tubos y
0.12 kg/cm2 para la carcasa. Para esto se usarán tubos 1 plg de diámetro externo y 14 BWG.
Por necesidades de mantenimiento se debe utilizar un arreglo cuadrado con espaciado de 1
¼ plg. Los tubos serán de acero al carbón.
Do = 0.0254 m
BWG14
Xw =2.1082x10-3 m
Dw = 0.023228 m
Arreglo cuadrado
= 995 kg/m3
k = 0.5383 Kcal/hrmºC
Cp = 1 Kcal/kgºC
Dietanolamina(fluido caliente)
mh = mo =50000 kg/hr
Tha = 127 °C
Thb = 79 °C
= 970 kg/m3
= 0.5329x10-3 kg/mseg
k = 0.4763 Kcal/hrmºC
Cp = 0.914 4Kcal/kgºC
Balance de calor
mC = 2194560/(1.0)(46 – 32)
mC = mi = 156754.2 kg/hr
Factor de corrección
127−79 46−32
R= =3 . 42 S= =0 .1473
46−32 127−32
Al iniciar los cálculos el primer punto a atacar es determinar si el flujo caliente o frío deberá
pasar por la carcasa. No hay una regla rápida para esto. Una corriente puede ser grande y la otra
pequeña, el espaciado de los deflectores puede ser tal que en cierta vez el de área de flujo del lado
de la carcasa sea grande. Afortunadamente cualquier selección se puede corroborar intercambiando
las corrientes y viendo que arreglo da los mayores valores del coeficiente global sin exceder la caída
de presión permitida. Particularmente y en preparación para métodos posteriores hay alguna
ventaja, sin embargo, de empezar los cálculos por el lado de los tubos, y será conveniente establecer
este hábito.
El cálculo para los coeficientes de película deberá empezar entonces en el lado de los tubos.
Para el resto de los cálculos que aquí se muestran, se supone que el fluido frío fluye en los tubos
como sucede en la mayoría, pero no necesariamente en todos los casos.
Cálculo de hi
Cuando el agua se mueve a baja velocidad a través de los tubos, el lodo y la lama
que resultan de la acción microbiana se adhieren a los tubos y serían arrastrados si hubiera
alta turbulencia. Como práctica común, deben evitarse velocidades menores de 0.9 m/seg
en agua de enfriamiento, aun cuando en ciertos procesos se requieren velocidades mínimas
de 1.2 m/seg para una operación continua. Otro factor de considerable importancia es el
depósito de incrustaciones minerales. Cuando el agua con un contenido promedio de
minerales y aire se lleva a una temperatura mayor de 50 °C, se encuentra que el
movimiento de los tubos se hace excesivo, y por esta razón deben evitarse temperaturas del
agua a la salida mayor de 50 °C. Para líquidos que fluyen por los tubos, es común utilizar
de 1 a 2 m/seg como velocidad de diseño.
Propuesta. Si el agua va por el interior de los tubos y si se usa una velocidad de diseño de 1.2
m/seg.
156754 .2
=0 . 03646 m2
Área por paso = ( 3600 )( 1 .2 ) (995 )
Con este número de tubos buscamos en el apéndice 26 el número de tubos más cercano
(conociendo el arreglo, número de pasos, espaciado y diámetro de los tubos)
El arreglo más apropiado será de DI =23.25 plg, y 208 tubos
hi = 0.023(ki/Di)(Rei)0.8(Pr)0.33
hi = 4585.1 Kcal/hrm2ºC
ho = 0.36(ko/De)(DeGS/o)0.55(Cpoo/ko)0.33
GS = mo/AS
AS = (BDIC’)/PT
C’ = PT – Do = 6.35x10-3 m
Propuesta, B = DI/5 = 0.118, con deflectores 25 % de corte,
50000
GS= =999. 2 kg/m 2 seg
( 0 . 0139 )( 3600 )
ho = 4025.2 Kcal/hrm2 ºC
1
U o= −3
1 1 ( 2. 1082 x 10 ) ( 0. 0254 ) 0 . 0254 1
+ + + +
3000 4025. 2 ( 39 )( 0 . 023228 ) ( 0 .0211836 ) ( 4585 .1 ) 1480
Uo = 1/(3.33x10-4+ 2.483x10-4 + 5.969x10-5 + 2.625x10-4 + 6.756x10-4
Uo = 633 Kcal/hrm2ºC
Q = UoAoTmFT
2194560 = 633(Ao)(62.46)(0.97)
A0 = 57.17 m2
Cálculo de la longitud
A0 = Do LNT
L = A0/Do NT
Pi = (fivi2LNPi)/(2gCDi)
La caída de presión dentro de los tubos está dentro del valor permitido.
Po = (foGS2(N+1)DI)/(2gCDeo)
De = 0.025 m
La caída de presión calculada por el lado de la carcasa es mayor que la disponible, por lo tanto se
tiene que modificar el cálculo; para estos casos se tienen varias alternativas, por ejemplo, modificar
la velocidad o modificar el espaciado de los deflectores. Si se modifica la velocidad ya sea
aumentar o disminuir el valor, esto provocaría un cambio también en la caída de presión en los
tubos, en los coeficientes, la longitud y número de tubos. La otra modificación, la del espaciado,
puede ser más razonable en cuantos al número de cálculos que se tendrían que hacer, ya que esta
modificación solo afecta al coeficiente externo y a la caída de presión externa. Se procederá con
este cambio:
B = 0.59/4 = 0.1475
GS = mo/AS
AS = (BDIC’)/PT =(0.147x0.59x6.35x10-3)/0.0317
AS = 0.01737 m2
GS = 50000/(0.01737x3600)
GS = 799.5 kg/m2seg
ho = 10.54(328.22)
ho = 3459.4
cálculo de U
Uo = 1/(1.33x10-3 +1/3459.4)
Uo = 617
Cálculo de Ao
2194560/(617)(62.46)(0.97) = Ao
A0 = 58.70 m2
Cálculo de la longitud
A0 = Do LNT
L = A0/DoNT
(N+1) = 23.9
GS = mo/AS
AS = (BDIC’)/PT =(0.1966x0.59x6.35x10-3)/0.0317
AS = 0.0232 m2
GS = 50000/(0.0232x3600)
GS = 597.7 kg/m2seg
ho = 10.54(0.025x597.7/0.532x10-3)0.55
ho = 10.54(279.6)
ho = 2947.9
cálculo de U
Uo = 1/(1.33x10-3 +1/2947.9)
Uo = 599
Cálculo de Ao
2194560/(599)(62.46)(0.97) = Ao
A0 = 60.46 m2
Cálculo de la longitud
L = A0/DoNT
(N+1) = 18.52
GS = mo/AS
AS = (BDIC’)/PT =(0.295x0.59x6.35x10-3)/0.0317
AS = 0.0348 m2
GS = 50000/(0.0348x3600)
GS = 398.36 kg/m2seg
ho = 10.54(0.025x398.36/0.532x10-3)0.55
ho = 10.54(223.75)
ho = 2358.3
cálculo de U
Uo = 1/(1.33x10-3 +1/2358.35)
Uo = 570
Cálculo de Ao
2194560/(570)(62.46)(0.97) = Ao
A0 = 63.53 m2
Cálculo de la longitud
L = A0/DoNT
(N+1) = 12.97
El valor es menor que el disponible, por lo tanto puede operar bajo las condiciones establecidas.
27. Cierto cambista de calor tiene un paso de carcasa y cuatro pasos de tubo, con un área
de superficie total de 9.29 m2. Aceite con un calor específico de 0.6 Kcal/Kg°C entra a una
temperatura de 176.6 °C a una razón de 16 galones por minuto. Se dispone de agua
refrigerante a una razón de 2724 Kg/h, con una temperatura de 15.55 °C. Determine las
temperaturas de salida del aceite y del agua si el valor de U es de 878.4 Kcal/hm2°C.2
Solución:
Datos: Un cambista de calor con un paso de cáscara y cuatro pasos de tubo tiene un área de
superficie total de 9.29 m2. El coeficiente de transferencia de calor es de 878.4
Kcal/hm2°C. Se utiliza al cambista de calor para enfriar aceite. Para el aceite, T h,i = 176.6
°C, ch = 0.6 Kcal/Kg°C, y la razón de flujo = 16 GPM. El refrigerante es agua a 15.55 °C
con una razón de masa de 2724 Kg/h.
C min
R=
C max
UA
NUT =
Cmin
Para Ch < Cc
T co −T ci
ε=
T hi−T ci
Para Ch > Cc
T hi −T ho
ε=
T hi −T ci
Cc ( Tc,o – Tc,i ) = Ch (Th,i – Th,o )
Propiedades:
Th,i = 176.6 °C
= 817.31 Kg/m3
C min 1770.6
R= = =0.65
C max 2724
UA ( 878.4 ) (9.29)
NUT = = =4.5
Cmin 1781.66
T hi −T ho
ε =0.70=
T hi −T ci
176.6−T ho
0.70=
176.6−15.55
Dando
Th,o = 63.865 °C
De la ecuación de energía
Obtenemos
o bien
Tc,o = 89.29 °C
Comentarios: Del análisis vemos que la temperatura del aceite en la salida es de 63.865 °C
y la temperatura del agua en la salida es de 89.29 °C.
28.- Un intercambiador 1 – 2 funcionando con un paso por la coraza y dos por los tubos,
calienta 2.52 kg./s de agua desde 21.1 hasta 54.4 ºC usando agua caliente a presión que
entra a 115.6 y sale a 48.9 ºC. El área superficial externa es Ao = 9.3 m2 .
b) ¿Cuál sería el valor de Tm para las mismas temperaturas en un intercambiador 2–4
a)
( T hi−T ho ) ( 115.6−48.9 )
Z= = =2
( T co−T ci ) (54.4−21.1)
( T co −T ci ) (54.4−21.1)
Y= = =0.352
( T hi−T ho ) ( 115.6−48.9 )
Q 302100
Uo= = =1037 Kcal/hr m 2 ° C
Ao ∆Tm ( 9.3 ) (31.3)
b)
El coeficiente integral de transmisión del calor desde el agua hasta la pared, referido al área
interna de los tubos, es de 350 Kcal/mh°C; el flujo de masa de ácido acético a través de
cada tubo es 250 kg/hr y a 40 °C su calor específico 0.50 Kcal/Kg°C.
Solución:
( 95−80 )
Z= =0.375
(60−20)
( 60−20 )
X= =0.533
( 95−20 )
Gráficamente: Y=0.95
35−60
∆ T log = =46.4 ° C
35
2.3 log
60
El área será
4000
A= =0.25
( 350 )( 44)
0.25
L= −4
=7.85
π (10 )
30. En un cambiador tubular de ocho pasos en los tubos y un solo paso en la carcasa,
circula un gas caliente por el lado de está última, mientras que a través de los tubos fluye un
líquido. El gas entra a 70°C y sale a 39°C , el líquido entra a 11°C y sale a 30°C. Si el
coeficiente global de transferecia de calor Uo es 27 Kcal/hm2°C y la velocidad total de
transferencia de calor es de 25000 Kcal/h, hállese el área total de transfencia de calor.3
Solución:
30−11
X= =0.32
70−11
70−39
Z= =1.63
30−11
Las diferencias de temperatura terminales para flujo en contracorriente son: t1 = 28°C y
t2 = 40°C. El área total de transferencia de calor es
25000
Ao= =30.5 m2
(40−28)
( 27 ) (0.9)
ln(40 /28)
5. En una planta de proceso se deben enfriar 308710 kg/hr de condensados desde 91 hasta
86 °C por medio de agua tratada de enfriamiento que entrara a 32 °C y saldrá a 40 °C.
Diseñe el cambiador de calor apropiado para este servicio.
Qg = Qc
A=?
Q
A= =Π DoLN T
U o ΔT m
kcal
Q=(308710×1 .0047×91 . 86)=1550804 .685
hr H 2 Opura
mCp ΔT =Q
Q 1550804 . 685 kcal
m= = =194110. 694
Cp ΔT ( 0. 99866 )(40−32) hr
Np = 2
(Tha−Tcb )−(Thb−Tca)
ΔT m=
(Tha−Tcb )
ln
(Thb−Tca )
( 91−40 )−(86−32) −3
ΔT m= = =52. 63 m2
(91−40 ) −0 .057
ln
(86−32)
(Tha−Thb) (91−86 )
R= = =0. 625
(Tcb−Tca) ( 40−32 )
(Tcb−Tca) (40−32)
S= = =0 . 135
(Thb−Tca) (91−32)
FT = 0.9
Π 2 472
Af nueva =
4
Di( )
2
=0. 083 m2
1
V=
m
=
308710 (
3600 )
=1. 609 m / s≈1 .07 m/ s
ρ Af 966 . 27( 0 . 083 )
Di V ρ (0 . 021183)(1 . 07)(966 . 27 )
Re= = =67805. 85
μ 0 . 323×10−3
0.33
k 0 .8 Cp μ
hi=0 . 023
Di
Re ( )
k
φi
0 . 33
( 0.602) 1.0047⋅0.323×10−3
hi=0.023
(0.021183)
(67805.85)0.8 (
0.602 ) φi
0 .55 0 .33
k DeGS Cp μ
ho=0.036
De μ ( ) ( ) k
φo
ms
GS=
As
Ds = 31’ = 0.7874 m
−3
BC ' Ds (0 . 16 )(6. 35×10 )(0 .7874 )
As= = =0 . 0252m2
PT 0 . 03175
As = 0.0252 m2
(194110. 694 ) kg
GS= =7702805. 32 2
(0 . 0252) m s
1
Uo=
∑R
m2 h °C
H 2 O pura =1. 02×10−4
kcal
m2 h° C
H 2 Otratada =3 .07×10.4
kcal
Acero inoxidable
Do = 0.0254 m
Di = 0.021183 m
Xw = 0.002108 m
Aftubo = 0.000352257 m2
DoXw
Rw=
KwDm
Π 2 NT Π 2 NT
Af total = Di = Di
4 NP 4 2
V =1 m/s
(turbulento)
NT 0. 088
= =249 . 82
N P 0. 000352257
Ds = 31
0 .55 0. 33
(0. 538 ) 0 . 017×7702805. 32 0 . 99866×0. 7124×10−3
ho=0 .036
(
(0 . 017 ) 0 .7124×10−3 ) ( 0. 538 ) φo
0. 14
0. 325×10−3
μw =0 . 470×10
−3
φi=
(
0 . 470×10−3 ) =0 .94
0 . 14
0 .7124×10−3
φo=(0 . 470×10−3 ) =1 .05
ho 4711. 14
Twc=Th− (Th−Tc)=88. 5− (88 . 5−36 )=40 °C
hi+ho 4711. 14+373 . 74
0. 14
0. 323×10−3
φi= (
0 . 654×10−3 ) =1. 01
0 . 14
0 .7124×10−3
φo=
( 0 .654×10−3 ) =1 .09
hi=397.6(1.01)=401.6 Kcal/m2 h° C
ho=4486.8(1 .09)=4890. 6 Kcal/m2 h° C
ho
Twc=Th− (Th−Tc)=40°C
hi+ho
1 1
Ro= = =2.04 x 10−4 m2 h°C / Kcal
ho 4890 .6
Do 0. 0254
Ri= = =2.98 x 10−3 m2 h° C /Kcal
Dihi (0 .021183)(401 .6)
1
Uo=
4 .09 x 10−4 +1.02 x10−4 +3.07 x10−4 +2.98 x10−3 +2.04 x 10−4
Uo=249.88KCal /m2 h° C
Q 1550804 .685
Ao= =
Uo ΔTmFt (249.88)(52.63)(0. 9)
Ao=131.02m2
7.- Se desea calentar 3000kg/h de alcohol etílico desde 10 a 60°C usando agua caliente que
parará de 90 a 65 °C. Se permitirán 7kg/cm2de caída de presión en cada corriente. Para este
servicio se tienen tubos de acero de ¾ de pulgada, 13 BWG, de 2m de largo. Se requiere
una velocidad en los tubos cercana a 1m/s.
Propiedades:
hi=2629 .05ϕi
Thp−Tcp
Twp= =56.25 ° C
2
μ 0.14
ϕi= ( )
μw
=0. 977 ϕo=1.051
ho
Twc=Thp− (Thp−Tcp)=62.84 ° C
ho+hi
Twp≠Twc aprox 7°
1377 .08
Twc=77.5− (42.5)=62 .79 ° C
1377 .08+2602 .75
Twp y Twc aproximadamente iguales
1
U 0=
(5 .14+7.26+1. 991+3.07+2. 04)x 10−4
U 0=512.79 Kcal/m2 ° Ch
Donde:
Rdi=3 . 07x10-4 m2 h °C / Kcal
Rdo=2 . 04 x10−3 m2 h ° C /Kcal
Rw=1 .991 x10−4 m2 h ° C/ Kcal
Do 0. 01905 −4 2
Ri= = =5 .14 x10 m h °C / Kcal
hiDi (2602.75 )(0. 014224 )
1 1
Ro= = =7 .26 x10−4 m2 h ° C /Kcal
ho 1377 .08
Q 93750
A 0= = =5 .03 m2
U 0 ΔTFT (512 .79 )(41 . 24 )( 0.88 )
A0 5 . 03
Ntc= = =42. 02
π DoL π (0 . 01905)(2 )
Para saber si es correcto Ntp< Ntc debe cumplirse .
Ntp=32 Ntc=42. 02
32<42 .02
∴ Si es correcto