Documentos de Académico
Documentos de Profesional
Documentos de Cultura
CALCULOS 1 BTU =
h6 = h5 + Wp1
Wp1 = v5 (P6 - P5) DIAGRAMA DE
WP1 = TRABAJO DE LA BOMBA 1
WP1 = 0,01607 ft3/lb (310 - 0,5) PSI = 0.920 BTU/ lb
h6 = 47,6123 + Wp1 = BTU/ lb
h6 = 47,6123 + 0,920 = 48.533 BTU/ lb
h8 = h7 + Wp2
Wp2 = v7 (P8 - P7)
WP2 = TRABAJO DE LA BOMBA 2
Wp2 = 0,01894 ft3/lb (620 - 310) PSI = 1.086 BTU/ lb
h8 = 397,26 + Wp2 BTU/ lb
h8 = 397,26 + 1,086 = 398.346 BTU/ lb
h10 = h9 + Wp3
Wp3 = v9 (P10 - P9)
WP3 = TRABAJO DE LA BOMBA 3 ❿
Wp3 = 0,02021 ft3/lb (1000 - 620) PSI= 1.421 BTU/ lb
h10 = 475,887 + Wp3 BTU/ lb
h10 = 475,887 + 1,421 = 477.31 BTU/ lb DIAGRAMA DE
❶ 1 WE
CONDENS
ADOR
1 ❷
2
❸ ❹
ṁ2 1-ṁ2-ṁ3
ṁ3
❺
1
❻ P1
ṁ2
❾ ❼
ṁ3
P3 ❽ P2
DIAGRAMA DE LA PLANTA
1-ṁ2-ṁ3- CICLO RANKINE REGENERATIVO
Continuación:
SE DEBE CALCULAR:
HR = 3413 / Ƞ
SR = Ƞb HR / (h1 - hf)
CONCLUSIONES:
*El ciclo Rankine regenerativo, se llama asi porque utiliza uno o mas regenera
dores o calentadores de agua, para incrementar la temperatura del agua de
alimentación de la caldera, este ciclo no solo mejora la eficiencia, sino que
sirve para desairear el agua de alimentación y evitar la corrosión.
* HEAT RATE, es una medida que determina el desempeño del ciclo
Cuanto mayor sea la eficiencia termica, menor es la rata termica HR, o tambien
cuanto menor sea la rata termica, se aumenta la eficiencia termica;
osea mas eficiente, se necesitara menos E. termica para generar mas E. electrica
* STEAM RATE, permite calcular la capacidad de la caldera, tanto para
diseño, como para evualuar un sistema existente.
por caldera
a de alimentacion
ca del ciclo
78 BTU/Lb
= 44,62%