Motor Insights
Advanced Overloads
Motor Insights
Performance
Motor Insight
Advanced Monitoring
Advanced Protection
Communications
1 - 540A FLA, 240-600VAC
IT.
Solid-State OLR
Communicating
0.25 - 400A
Motor Protection
C396 - Standard
C440
Freedom C306
Thermal OLR
0.25 - 1500A
XT
Thermal OLR
IEC only
0.1 - 630A
Price
3
Certifications
UL, CSA, CE, RoHS
Modulos de comunicacion:
Modbus (con y sin I/O)
DeviceNet con I/O
Profibus con I/O
Ethernet IP (Mid 2010)
Display remoto
Type 1, 12 and 3R
NEMA 3R
Motor Protection
Thermal Overload (Sobrecarga Termica)
Consecuencias:
Motor Protection
Motor Protection
Mechanical Jam (Salto de Carga)
Causas:
Consecuencias:
Motor Protection
Ground Fault (Falla Tierra)
Consecuencias:
Motor Protection
Unbalanced Phase Currents (Desbalance de corrientes)
Consecuencias:
Cuando una carga trifsica es alimentado con una lnea de baja calidad,
la tensin por fase puede ser desequilibrada causando corriente
desequilibrada
Cuando hay una fuga de corriente de fase a fase
Las corrientes desequilibradas pueden conducir a los bobinados del
estator del motor que se sobrecarguen, causando un calentamiento
excesivo, la reduccin de la eficiencia del motor y la reduccin de la
vida de aislamiento
Motor Protection
Phase Loss - Current (single-phasing) (Perdida de fase)
Source:
Consecuencias:
10
10
Motor Protection
Phase Rotation (phase-reversal) (Secuencia de fases negativa)
Causas:
Resultado:
NO TRIP DELAY
11
11
Load Protection
Undercurrent & Low Power (Baja corriente y Perdida de
Potencia)
Resultado:
Una parte de la carga del usuario desaparece, causada por una correa
rota, una bomba en seco (baja carga de succin), o una bomba
centrfuga-fuera.
Puede causar un calentamiento excesivo, daos en los sellos y romper
las condiciones normales de operacin deseadas.
12
12
Load Protection
High Power (Alta Potencia)
Resultado:
13
13
Line Protection
Over voltage (Sobre Voltage)
Causa:
Resultado:
Mal funcionamiento
14
14
Line Protection
Under voltage (Bajo Voltage)
Source:
Resultado:
15
15
Line Protection
Unbalanced Voltage (Desbalance de Voltages)
Definicion:
trifsico
Causa:
Cuando una carga trifsica es alimentado con una lnea de baja
calidad, la tensin por fase puede ser desequilibrado..
Resultado:
Tensin desequilibrada provoca corrientes de desequilibrio,
que conducen a los bobinados del estator del motor a
sobrecargas, provocando un calentamiento excesivo, reduccin
de la eficiencia del motor y reduccin de la vida de aislamiento
16
Motor Insights
El Motor Insight, el primer producto inteligente de
la familia de soluciones de control de energa de
Eaton, es un dispositivo de proteccin del motor,
carga y lnea altamente configurable con
supervisin de la alimentacin, el diagnstico y las
comunicaciones flexibles le permite al cliente
ahorrar energa, optimizar su programa de
mantenimiento, y configuracin de mayor
proteccin del sistema que extiende la vida del
equipo, lo que reduce los costos generales y el
tiempo de inactividad
17
17
Three 480V 75 hp, 96 amp tripping-current motors at Indiana Ave lift station
Flow was the same for all three pumps, however with Motor Insight they
observed pump 3 drawing abnormal current due to a foreign object on the
impeller
Motor Insight - Value Add:
ENERGY SAVINGS
Motor 1
Motor 2
Motor 3
Draws 60
amps
Draws 60
amps
Draws 90
amps
18
Limited operational information required weekly inspections of motors and pumps in hard to
access areas 30 FEET DOWN!
No pre-notion of problems that could be occurring, so individual may be over or underqualified for issue at hand
MAINTENANCE OPTIMIZATION
Eliminating Unnecessary Inspections: Knowledge of real-time data along with 10 history fault-queue enables for
sending personnel only when data from Motor Insight indicates an issue
Optimizing Labor Skill Sets: Understanding of fault-type allows for appropriate maintenance personnel selection.
Having the right man for the job enables the plant to better utilize skill sets reducing wage rates per service trip I.e. dont send
your 40-year maintenance person to clear a clog
Reducing Service Time: Understanding of fault-type allows for proper tool selection before heading to site, avoiding
costly second trips and reducing service time
Pre-Motor Insight:
50 service trips/year * 2 labor heads * $40/hr * 2 hours/service trip = $8,000/yr
Post-Motor Insight:
19
A centrifugal pump is pumping against a mostly closed valve. The pump continues to run
because the float limit switch is not dropping as the water level is not decreasing. A second
pump is turned on to compensate, thus two pumps are running and are performing the work of
essentially one pump
Pre-Motor Insight:
Motor Insight Value - Add: EXTEND EQUIPMENT LIFE & REDUCE DOWNTIME
Reduction of wasted run-time hours: Due to the protective-fault feature called Under Power Motor Insight faulted
Motor 1 taking it offline (A centrifugal pump goes to low power in a dead-headed scenario). Pump 2 came online and
completed the pumping activity. Pump 1 was saved from doing non value-add work, extending the life of the bearings
Reduction of wear on components: Motor Insights advanced protection offering ensured that the seal on Pump 1
did not heat up and therefore did not heat-age, thus the product life is extended
Motor Insight has 12 protective faults and the ability to monitor in real time, providing Motor, Load and Line protection
In this Scenario one of the Load protective settings, Low Power, prevented the heat-aging of the seal
20
Caracteristicas Genericas
10 Monitoring Choices
Confiabilidad
Comunicacion Flexible
Terminal Block
Seguridad
Facil uso
Mejor Diagnosticos
21
21
Proteccin Configurable
Motor Protection
Cada
falla
configurables
tiene
ajustes
Motor,
Load, line
Protection
Thresholds
Load Protection
Under-Current (10-90% of FLA)
Low Power (kW) (lowest power in range)
Line Protection
Over voltage (170-660V)
Under voltage (170-660V)
Voltage Imbalance (1-20%)
22
Transient state
without
configurable start
cycle, start-up can
be impossible
23
23
Sistema de Monitoreo
Monitoreo de.
Current Per Phase and Average RMS
Conserve energy
Optimize
your
maintenance
preventive
Power
Power Factor*
Frequency*
Motor Run Hours*
Thermal Capacity
*Available in Advanced Configuration menu
*When using communications additional data is available
24
24
Comunicaciones Flexibles
Communication
Port
Modbus Module
DeviceNet +
I/O Module
25
Diagnosticos
F.14 is a Jam Fault, No Deciphering of
Fault Codes is Needed!
Motor Insight stores the last 10 faults (best in class) in a
Diagnostics
non-volatile memory
Time-stamping faults
26
This chart demonstrates the amount of inspections that have to take place in order
to find the root cause of a thermal overload trip when using a Bi-Metal or an
Electronic Overload
As you can see, for a Thermal Overload trip there could be 17 different root
causes, meaning the user has to check 17 aspects of their system
If they dont find the true root cause, the failure will occur over and over leading to
unscheduled downtime and loss of productivity
27
Number of
Possibilities
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
17
27
Possible Cause
Worn motor bearings
Worn pump bushings
Increase in motor load
Undersized motor
Loose wire
Improper motor wiring
Grounded phase
Open fuse
Mechanical interference with motor
Mechanical interference with driven load
Phase-to-phase leakage path
Unbalanced voltage from poor line quality
Line to ground leakage path
Dead-head positive displacement pump
Change in process material properties
Poor incoming line quality
Poor incoming line quality
Poor incoming line quality
A mis-wired motor
Inadvertent phase reversal by the utility
Change in the load: broken belt, low suction head, dead-headed centrifugal pump
Rise in line voltage
Change in the load: broken belt, low suction head, dead-headed centrifugal pump
Average number of inspections required if using a Motor Insight Overload and Monitoring Relay =
Single Phasing
Jam Trip
Current Unbalance
Ground Fault
High Power
Under Voltage
Voltage Unbalance
Over Voltage
Phase Rotation
Under Current
Under Power
Number of
Possibilities
Due to Motor Insights numerous fault indications, the user can eliminate the
majority of possible causes
Motor Insight also provides fault indications for faults that do not lead to higher
currents, giving you more information about your Load and Line
28
4
2
2
1
2
1
1
1
2
2
1
1.92
28
Enfoque a la seguridad
Finger Proof
29
Remote Display/HMi
Terminaes adicionalesI/O
30
Codigos
Reduced Inventory
31
31
Objetivo y Aplicaciones
Dadas las capacidades de configuracin avanzada de Motor Insight tanto
en monitoreo, comunicaciones y caractersticas de proteccin se orienta a
cargas y motores crticos dentro del proceso
Target Markets
Applications
32
C441 Seleccion
Motor Insight Voltage and Current Range Selection using Tables 3 and 4 from the
Catalog, CA042090001E
33
33
Preguntas?
Resumen
Tres beneficios y ventajas de MotorInsight?
Mejor Diagnostico, Extension Vida Util, Ahorro de Energia,
Optimizacion de Mantencion
35
35
36
37
37
Configuracin Tipica
38
38
39
39
40
40