QSK78 MCRS Cylinder Head Gasket Leak – Thermal Damage
to Grommet
Failure Mode
• Customer observes coolant leak originating from under the engine’s cylinder head. Upon further investigation it is
discovered that the cylinder head gaskets have been damaged; specifically thermal damage/ degradation at two
coolant grommet locations.
Field Countermeasure
• Fix as fail.
Corrective Action
• Production and Service: TBD.
Cummins Confidential 9
QSK78 CM500 Camshaft
Thrust Bearing
Capscrews Backing Out
PITS: OB823-36726
Cummins Confidential
QSK78 CM500 Camshaft Thrust Bearing Capscrews Backing Out
Failure Mode
• Customers notice unusual loud noise; engine shuts down suddenly. Troubleshooting reveals FC222 related to the
Electronic Chip Detectors (ECD). Further inspections of both ECDs reveal metallic particles. The left bank Camshaft thrust
bearing capscrews are backed out and have fallen into the gear train.
Field Countermeasure
• Use of old thrust bearing PN 5376260 (3082437)
Corrective Action
• Production: TBD
• Service: TBD
Cummins Confidential 11
Rocky Mountain QSK60 Cylinder Bolt Hole Crack Repair
12
ESN 33174627
Crack Discovered
ESN 33174066
ESN 33174627
~25,000 hours
Wall thickness .305 in
Bolt hole depth 3.487
13
Crack Drilled and Inserts
Installed
14
Post Insert
15
Thread Insert
Cummins
Service Part
One concern is the additional depth required to install this insert flush with
head deck (*Cummins insert must be installed below the head deck or there is
not adequate head bolt engagement depth)
16
QSK60/78/95 MCRS
Erratic crankcase pressure
reading and trending
Incorrect CCPS installation on
Q78 / Q95
Escalation #924
Issue description : Crankcase pressure sensor ( PN 4954405 ) shows erratic reading / trending causing FC without issue
List of reported TSR’s 4 sensors to be returned to the supplier Trafag in Switzerland, 2 on route via SSC
Investigation results pending
5th sensor available in Chile in case of need
As per CES 14609 as well as supplier specification sensors require a vertical installation.
QSK78CM2350 and QSK95CM2350 does have a horizontal installation, see slides 9 & 10
Unknown at this stage if the direction of installation has a direct impact on the reading,
but it is outside of engineering standard and re-design is highly recommended.
Alternative solution could be the addition of an 90 degree elbow where space permits and cable length is not
compromised, otherwise a different location needs to be specified, which may require a cable extension.
In comparison other HHP product is installed vertically, see slides 12, 13, 14 & 15
18
TSR Summary
19
20
New sensor installed
21
22
Findings so far :
1.) initial returns to Trafag during Infant care : NTF
2.) Sensor found painted on critical location ( membrane )
3.) Installation directions are not met, neither supplier nor CES
standard
4.) else, pending feedback from Trafag from sensors returned
( 2 x QSK60, 2 x QSK78 )
23
Sensor
PN 4954405
Supplier
Trafag
24
Sensor PN 4954405
Supplier Trafag
25
Excerpt from CES 14609
26
QSK78 CM2350 – installed in Breather
box
27
QSK95 CM2350
Hand hole
Cover #5 LB
CCPS #1
Real crankcase pressure
QSK95 CM2350
CCPS #2
“Coalescer pressure“
Indicating a plugged
breather 28
QSK38 CM2150
HHC located RB 1&2
29
QSK50 CM2150
Oil filler HHC located # ??
30
QSK60 CM2150
RB cylinder #1 head deck
31
QSK60 CM2350
RB cylinder #1 head deck
32
QSK78 CM2350
Sprint project
solution / step 3
Exceeding angularity
- +/- 30 degrees ?
33
QSK78
CM2350
proposed
location,
HHC requires
modification
to adopt
elbow
34
Q78MCRS HHC
installation port details
requires alternative elbow
or machining of HHC
Elbow PN
4967227(8
)
HHC port
Sensor
port
35
QSK95 CM2350
proposed
solution using
elbow PN 4967227(8)
Thread port in HHC does
match
36
Q95 HHC installation
port details
Elbow PN
4967227(8
)
HHC port
Sensor
port
37
38
38
QSK95 en patio de armado Antamina
Series 37285641 y 37285703
39
39
Q and A
40
40