Está en la página 1de 8

Pág: 1

RT-10-SA_-MNO-BRU-001
De: 8

CLIENTE: YACIMIENTO CARBONIFERO RIO TURBIO (YCRT)

PROYECTO: CENTRAL TERMOELECTRICA RIO TURBIO 2x120 MWe

ESTANDARES

16-09-2011

ESTÁNDARES DE PINTURA DE LOS EQUIPOS

Rev00

0 19/05/2011 VERSIÓN INICIAL AC AC AC


REV FECHA DESCRIPCION AUTOR REVISADO APROBADO

RT-10-SA_-MNO-BRU-001_REV00_ESTANDARES DE PINTURA DE LOS EQUIPOS


434-10-PM25200-0004-0001-A
ESTÁNDARES DE PINTURA DE LOS EQUIPOS 2011-5656
5656-DT0-17

INDICE

COMPUERTAS + REJAS + FILTROS

ROOF-TOP

RT-10-SA_-MNO-BRU-001_REV00_ESTANDARES DE PINTURA DE LOS EQUIPOS


ESTÁNDARES DE PINTURA DE LOS EQUIPOS 2011-5656
5656-DT0-17

COMPUERTAS + REJAS +
FILTROS

RT-10-SA_-MNO-BRU-001_REV00_ESTANDARES DE PINTURA DE LOS EQUIPOS


Componente chapa Características
Recubrimiento Z-275
Proceso Galvanizado
Especificación DX51-D
Proveedores de Anodizado según requerimientos de
Proceso Anodizado
Sistema EURAS.
Componente lama Características

Promatec Promatect H
Pladur Pladur FOC
ESTÁNDARES DE PINTURA DE LOS EQUIPOS 2011-5656
5656-DT0-17

ROOF-TOP

RT-10-SA_-MNO-BRU-001_REV00_ESTANDARES DE PINTURA DE LOS EQUIPOS


Project name: RIO TURBIO Creation date: 6/05/11
Description:
Customer:
End user:

MODEL: D4IC 360 G


PERFORMANCE
Cooling
Total Gross cooling kW 123,3
Total Net cooling kW 114,2
Outdoor temp DB / WB ºC 35 / 26
Mixing temp DB / WB ºC 27,8 / 19,7
Supply temp DB ºC 14,1
Heating
Heating capacity kW 0 + 37
Indoor fan
Airflow m3/h 21.000 ACCESSORIES
Available static pressure Pa 367
Code Name
613993601 Dry bulb economizer
Outside air percentage % 10 613994880 Power exhaust
Indoor fan power kW 9,1 611303680 Washable air filter set G4 (EU4)
Electrical data 613990084 Filter dirty switch
613113680 Low ambient control 360 and 480
Power input per compressor kW 57,7 611763384 Electric heater 37 kW (2 stages)
Main power supply 400V/3+N/50Hz
Automatic switch (K curves) A 108.0 / 54.0
Maximum total intensity A 125.0 / 63.0
Min. power cable mm2 5x50.0 / 5x16.0
Thermostat shield cable mm2 10 x 0.22
Refrigerant circuit
Number of compressors 3
Number of circuits 3
Refrigerant R-407C GENERAL FEATURES
Complete package factory charged, wired and tested.
WORKING RANGE Scroll compressors with crankcase heater
All cooling circuits equipped with High and low pressure switches,
Cooling Suction line antifreeze thermostat, Liquid line filter-dryer, Discharge
Mixing air indoor coil WB ºC 14 / 23 temperature cut-off switch, Liquid sight glasses and Suction
accumulator (on heat pumps).
Outdoor temp. DB ºC -10 / 46
- YKlon 24 V control circuit board and DPC-1 thermostat with
Heating communication.
Mixing air indoor coil DB ºC -- / -- - Removable media 48 mm filter EU 3 and F1 fire resistance (DIN
53438) on metal frame. All service doors with ?-turn locks quick
Outdoor temp. DB ºC -- / --
access panel.
- Zinc-aluminium coated steel sheeting treated with oven-baked
SOUND POWER (DBA) polymerised paint RAL9002 (800 H.N.S. in compliance with DIN
Outdoor 50021).
- Blue or copper fin coils available as option.
Global sound power level dB (A) 93 - Air sections fully insulated with 10 mm thick aluminium foil
Sound pressure level at 10m dB (A) 65 Basotec (M1 fireproof in compliance with UNE 23727).
Indoor Belt drive with adjustable pulley and indoor smooth start motor
Main switch and phase detector
Global sound power level dB (A) 86
Please, include the surface preparation process and the
technical data sheets of the coating products used.

NOTE Page 1 of 2
- In order to maintain data updated, YORK reserved the rights to change specification without prior notice
- For all detailed information, refer technical information
Unitary Support Group

AIR SYSTEMS PRODUCTS

BULLETIN A-2003-08-Anti-corrosion blue protected fin

Distribution list: A+B+C


List A : Confidential : for the intention of the sales managers and authorized people Bulletin would include : TP, strategic information, sales information, marketing information
List B : Sales information, for the intention of the sales people. Bulletin would include : sales arguments, commercial and technical documentation, information on range
List C : Technical information : for the attention of the technical support and service people, Bulletin would include : technical documentation, information on range modifications; technical
information

CFI: Ignasi SERRA; Ghislain BOURREE; Philippe GERY; Pedro Herrero; Xavier_Perise; Roman LARRODA; Xavier PALAU; Lluis Albaiges;
Narciso HERNANDEZ; Jose Manuel ABELLAN; jaime VAQUE

Date: April 2nd, 2003

Dear colleagues,

Please note find herewith the specifications of the anti-corrosion blue protected fin.

Units concerned:
- YCSA
- Roomtop
- Rooftop
- Large split

Polyurethane based lacquer:


This lacquer has high chemical and physical resistance, it is heat resistant and does not allow bacterial
growth.

Standards Properties
Heat resistance 200°C during 5 min. O.K.

Trichloroethylene 85ºC, 5 min Weight Loss < 1%


Resistance to
solvent
Perchloroethylene 120ºC, 30 min Weight Loss < 1%
Salt Spray
Corrosion Test ASTM B117 NACL 5%, 35 OC Up to 1000 hours

Kesternich Test ISO 3231 0.2 SO2 liters Up to 15 Cycles

ASTM G87 (500 hours, UV-313 4h. 60ºC /


UV Resistance O.K.
condensation, 4h. 40ºC)

Heat transfer Reduced compare to aluminum fin 4%


Final aspect :

Remaining at your disposal.

Best Regards

Air Systems Product Manager