Está en la página 1de 12

DISEÑO DE ZAPATA COMBINADA

Datos

Parametros del suelo


σt = 1.85 [kg/cm2] (tension adminisble del terreno)
γt = 2.0 [tn/m3] (Peso primedio del suelo y cimentacion)
df = 1.5 [m] (Fondo de cimentacion)
s/c = 500 [tn/m2] (Uso de la edificacion)

Columna C1 50 x 50

Cm = 60.0 [tn] (Carga muerta)


Cv = 30.0 [tn] (Carga viva)

Columna C2 50 x 50

Cm = 70.0 [tn] (Carga muerta)


Cv = 40.0 [tn] (Carga viva)

f´c = 210 [kg/cm2]


fy = 4200 [kg/cm2]

50 50
50

50

C1 C2

s= 4.80 B

CALCULO DE CARGA DE SERVICIO


CARGA C1 CARGA C2

CM = 60.0 Tn CM = 70.0 Tn
Cv = 30.0 Tn Cv = 40.0 Tn

P.serv = 90 Tn P.serv = 110 Tn

CALCULO DE LA CAPACIDAD PORTANTE NETA DEL SUELO

st = 18.50 - 2.00 x 1.50 - 0.5

st = 15 Tn/m2

CALCULO DEL AREA DE ZAPATA

90 + 110
Az =
15

Az = 13.33 m2 ###

DIMENSIONAMIENTO EN PLANTA DE LA ZAPATA

0.5 0.5
0.5

0.5

C1 C2

C.G

B
s= 4.80

0.25 r r
R= 200
Σ𝑀 1 = 0 ↺ (+)
110 x 4.80 + R x ( r - 0.25 ) = 0
2.6 528 50
r = 2.89 m

calculo de L

L= 5.78 = 5.80 m

calculo de B
𝐴𝑧 = 𝐵 𝑥 𝐿
B = 2.29828 = 2.30 m

0.50 0.50
0.50

0.50
C1 C2

= 2.30
B

L = 5.80

CALCULO DE CARGAS ULTIMAS


𝑃𝑂𝑅 𝑁𝑂𝑅𝑀𝐴𝑇𝐼𝑉𝐴
(PU = 1.4 ∗ CM + 1.7 ∗ CV)

PU1 = 135 Tn PU2 = 166 Tn

CALCULO DE LA REACCION NETA DEL SUELO : por metro lineal


(PUT = PU1 + PU2)

PUT = 301 Tn

Wu = 51.9 Tn/m

PU1 = 135 PU2 = 166


C.G

(1). (2). (3).

Wu = 51.9

0.25 4.80 0.75

elaboracion de diagramas Momento y Cortante

tramo (1)
+ ↑ Σ𝐹𝑦 = 0
+ 𝑊𝑢 ∗ 𝑋 − 𝑉𝑘 = 0

Vk = 51.9 * X

x= 0 → Vk = 0 Tn
x = 0.25 → Vk = 12.97 Tn

Σ𝑀 = 0 ↺ (+)

𝑥2
+ 𝑊𝑢 ∗ − 𝑀𝑘 = 0
2

x= 0 → Mk = 0 Tn
x = 0.25 → Mk = 1.62 Tn

tramo (2)
+ ↑ Σ𝐹𝑦 = 0
−𝑃𝑈1 + 𝑊𝑢 ∗ (𝑋 + 0.25) − 𝑉𝑘 = 0

Vk = 51.9 * X + 0.25 - 135

x= 0 → Vk = -122.03 Tn

Vk = 0
2.60133
x= 2.35 m
x= 2.35 → Vk = 0.00 Tn

hasta el eje de columna C2

x = 4.80 → Vk = 127.08 Tn

Σ𝑀 = 0 ↺ (+)
2
𝑥 + 0.25
+𝑃𝑈1 ∗ 𝑥 − 𝑊𝑢 ∗ + 𝑀𝑘 = 0
2
𝑥+0.25 2
Mk= 𝑊𝑢 ∗ 2
− 𝑃𝑈1 ∗ 𝑥

x= 0 → Mk = 1.62 Tn
x = 2.35 → Mk = -141.84 Tn
x = 4.80 → Mk = 13.75 Tn

tramo (3)
+ ↑ Σ𝐹𝑦 = 0
−𝑃𝑈1 − 𝑃𝑈2 + 𝑊𝑢 ∗ (𝑋 + 0.25 + 4.80) − 𝑉𝑘 = 0

x= 0 → Vk = -38.92 Tn
x = 0.75 → Vk = 0.00 Tn

Σ𝑀 = 0 ↺ (+)
2
𝑥 + 0.25 + 4.8
+𝑃𝑈1 ∗ 4.8 + 𝑥 + 𝑃𝑈2 ∗ 𝑥 − 𝑊𝑢 ∗ + 𝑀𝑘 = 0
2
2
𝑥 + 0.25 + 4.8
𝑀𝑘 = 𝑊𝑢 ∗ − 𝑃𝑈1 ∗ 4.8 + 𝑥 + 𝑃𝑈2 ∗ 𝑥
2

x= 0 → Vk = 13.75 [Tn]
x = 0.75 → Vk = 0.00 [Tn]

PU1 = 135 PU2 = 166


2.30
B=
L= 5.80
12.97 127.08

2.35 CORTANTE

-38.92
-122.03
-141.84

MOMENTO

1.62
13.75

CALCULO DE LA ALTURA DE ZAPATA

evaluamos con el cortante maximo a una distancia "d" Ø 1/4"0.6


𝑽𝒖 Ø 3/8" 1
𝒅= Ø 1/2" 1.3
(∅ 𝒙 𝟎. 𝟓𝟑 𝒙 𝒇´𝒄 𝒙 𝒃 + 𝑾𝒖)
Ø 5/8" 1.6
d= 62.89 [cm] Ø 3/4" 1.9 2.8
Ø 1" 2.5 5.1
𝑯 = 𝒅 + ∅𝒃𝒂𝒓𝒓𝒂 + 𝒓𝒆𝒄
Ø 1 1/8"2.9
Considerando Ø 5/8" D = 1.59cm Ø 1 1/4"3.2
Ø 1 3/8"3.5
H= 71.98 = 75.00 [cm]

Nota : con esta altura se garantiza la verificacion a cortante


recalculando "d" con la nueva H

𝒅 = 𝑯 + ∅𝒃𝒂𝒓𝒓𝒂 + 𝒓𝒆𝒄

d= 65.91 [cm]

VERIFICACION POR PUNZONAMIENTO


n1 n2

d/2
C1 C2

m1

m2
d/2 d/2

d/2 d/2

analisis para la columna C1 (exterior)


CALCULO DEL PERIMETRO CRITICO (bo)
𝒅
𝒎𝟏 = 𝟎. 𝟓𝟎 + 𝟐 ∗
𝟐
m1 = 1.159 [m]

𝒅
𝒏𝟏 = 𝟎. 𝟓𝟎 +
𝟐
n1 = 0.830 [m]

𝒃𝒐 = 𝟐 ∗ 𝒏𝟏 + 𝒎𝟏
bo = 2.818 [m] = 281.8 [cm]

CALCULO DEL AREA CRITICA DE PUNZONAMIENTO (Ac)


𝑨𝒄 = 𝒃𝒐 𝒙 𝒅

Ac = 1.86 [cm]

CALCULO DE LA FUERZA ULTIMA DE PUNZONAMIENTO (Fvu)

𝑭𝒗𝒖 = 𝑷𝑼𝟏 − 𝑾𝒖 𝒙 𝒎𝟏 𝒙 𝒏𝟏
Fvu = 85.1 [Tn]

CALCULO DEL ESFUERZO D EPUNZONAMIENTO ADMISIBLE Vu


(esfuerzo maximo que puede resistir la zapata)
𝑽𝒖 = ∅ 𝒙 𝑽𝒄
Ø = 0.85
𝟐
𝑽𝒄𝟏 = ∅ ∗ 𝟎. 𝟓𝟑 ∗ 𝟏 + ∗ 𝒇´𝒄 ∗ 𝒃𝒐 ∗ 𝒅
𝜷

Vc1 = 363788 = 363.788 [Tn]

𝒅
𝜶𝒔 ∗ 𝒅
𝑽𝒄𝟐 = ∅ ∗ 𝟎. 𝟐𝟕 ∗ + 𝟐 ∗ 𝒇´𝒄 ∗ 𝒃𝒐 ∗ 𝒅
𝒃𝒐
αs = 40 (columna interior)
αs = 30 (columna de borde)
αs = 20 (columna de esquina)

Vc2 = 556978 = 556.978 [Tn]

𝑽𝒄𝟑 = ∅ ∗ 𝟏. 𝟎𝟔 ∗ 𝒇´𝒄 ∗ 𝒃𝒐 ∗ 𝒅

Vc3 = 242526 = 242.526 [Tn]

El menor es

Vc3 = 242.526 [Tn]

𝑭𝒗𝒖 < 𝑽𝒖

85.1 < 242.526 OK cumple !!!

analisis para la columna C2 (exterior)


CALCULO DEL PERIMETRO CRITICO (bo)
𝒅
𝒎𝟐 = 𝟎. 𝟓𝟎 + 𝟐 ∗
𝟐
m2 = 1.159 [m]

𝒅
𝒏𝟐 = 𝟎. 𝟓𝟎 + 𝟐 ∗
𝟐
n2 = 1.159 [m]
###
𝒃𝒐 = 𝟐 ∗ 𝒏𝟐 + 𝒎𝟐
bo = 4.636 [m] = 463.6 [cm]

CALCULO DEL AREA CRITICA DE PUNZONAMIENTO (Ac)


𝑨𝒄 = 𝒃𝒐 𝒙 𝒅

Ac = 3.06 [cm]

CALCULO DE LA FUERZA ULTIMA DE PUNZONAMIENTO (Fvu)

𝑭𝒗𝒖 = 𝑷𝑼𝟐 − 𝑾𝒖 𝒙 𝒎𝟐 𝒙 𝒏𝟐
Fvu = 96.3 [Tn]
CALCULO DEL ESFUERZO D EPUNZONAMIENTO ADMISIBLE Vu (esfuerzo maximo que puede resistir la zapata)

𝑽𝒖 = ∅ 𝒙 𝑽𝒄
Ø = 0.85
𝟐
𝑽𝒄𝟏 = ∅ ∗ 𝟎. 𝟓𝟑 ∗ 𝟏 + ∗ 𝒇´𝒄 ∗ 𝒃𝒐 ∗ 𝒅
𝜷

Vc1 = 598491 = 598.491 [Tn]

𝜶𝒔 ∗ 𝒅
𝑽𝒄𝟐 = ∅ ∗ 𝟎. 𝟐𝟕 ∗ + 𝟐 ∗ 𝒇´𝒄 ∗ 𝒃𝒐 ∗ 𝒅
𝒃𝒐
αs = 40 (columna interior)
αs = 30 (columna de borde)
αs = 20 (columna de esquina)

Vc2 = 781164 = 781.164 [Tn]

𝑽𝒄𝟑 = ∅ ∗ 𝟏. 𝟎𝟔 ∗ 𝒇´𝒄 ∗ 𝒃𝒐 ∗ 𝒅

Vc3 = 398994 = 398.994 [Tn]

El menor es

Vc3 = 398.994 [Tn]

𝑭𝒗𝒖 < 𝑽𝒖

96.3 < 398.994 OK cumple !!!

DISEÑO DE ACERO LONGITUDINAL


diseño del acero superior
B = 2.30

141.84
1.62 13.75

altura efectiva "d"

𝑯 = 𝒅 + ∅𝒃𝒂𝒓𝒓𝒂 + 𝒓𝒆𝒄
Considerando Ø 5/8" D = 1.59cm

H= 71.98 = 75.00 [cm]

𝒅 = 𝑯 + ∅𝒃𝒂𝒓𝒓𝒂 + 𝒓𝒆𝒄

d= 65.91 [cm]

calculo de "a"

𝟐 ∗ 𝑴𝒖
𝒂 = 𝒅 − 𝒅𝟐 −
𝟎. 𝟗𝟎 ∗ 𝟎. 𝟖𝟓 ∗ 𝒃 ∗ 𝒇´𝒄

a = 6.11 [cm]

calculo de "As"

### 62.86
### ### 𝑴𝒖
𝑨𝒔 = 𝒂
𝟎. 𝟗𝟎 ∗ 𝒇𝒚 ∗ 𝒅 − 𝟐
As = 59.70 [cm2]

calculo de acero minimo

𝑨𝒔𝒎𝒊𝒏 = 𝟎. 𝟎𝟎𝟏𝟖 ∗ 𝒃 ∗ 𝒉

Asmin= 31.05 [cm2]

Asmin < 𝑨𝒔

31.1 < 59.70 OK cumple !!!


<
Usando barra de Ø 1" D = 5.10cm

Cantidad (n) = = 11.7054 = 12

Cantidad (n) = = 19.1667 = 20 [cm]

USAR: 11.78 12  1 " @ 0.20 m

diseño del acero inferior

calculo de "a"

𝟐 ∗ 𝑴𝒖
𝒂 = 𝒅 − 𝒅𝟐 −
𝟎. 𝟗𝟎 ∗ 𝟎. 𝟖𝟓 ∗ 𝒃 ∗ 𝒇´𝒄

a = 0.57 [cm]

calculo de "As"
𝑴𝒖
𝑨𝒔 = ### 65.63 𝒂
𝟎. 𝟗𝟎
### ∗ ###
∗ 𝒇𝒚 𝒅−𝟐

As = 5.54 [cm2]

calculo de acero minimo

𝑨𝒔𝒎𝒊𝒏 = 𝟎. 𝟎𝟎𝟏𝟖 ∗ 𝒃 ∗ 𝒉

Asmin= 31.05 [cm2]

Asmin < 𝑨𝒔

5.5 < 31.05 OK cumple !!!

Usando barra de Ø 3/4" D = 2.84cm

Cantidad (n) = = 10.9331 = 11

Cantidad (n) = = 20.9091 = 20 [cm]

USAR: 10.89 11  3/4 " @ 0.20 m


DISEÑO DE ACERO TRANSVERSAL

calculo de acero minimo

𝑨𝒔𝒎𝒊𝒏 = 𝟎. 𝟎𝟎𝟏𝟖 ∗ 𝒃 ∗ 𝒉

Asmin= 78.3 [cm2]

Asmin < 𝑨𝒔

78.3 < 78.30 OK cumple !!!

Usando barra de Ø 3/4" D = 2.84cm

Cantidad (n) = = 27.5704 = 28

Cantidad (n) = = 20.7143 = 20 [cm]

arriba y abajo:
USAR: 27.47 28  3/4 " @ 0.20 m

DISEÑO DE ACERO POR FLUENCIA DE COLUMNAS

b1 b2

C1 C2

0.75d 0.75d

0.75d