ECOPETROL

Hojas de datos - Válvulas reguladoras de


presión
INGENIERÍA DE DETALLE INYECCION DE AGUA 40 ACRES CAMPO CHICHIMENE -
MOC # 3 ESTACIÓN CHICHIMENE

Document No Rev 1: ECP-ULL-17070-GCH-ID06-0-INS-HD-006

28 Julio 2021

CONTRATO NO: 2021-3037741-04

1. APROBADO PARA DISEÑO / CONSTRUCCIÓN


2. APROBADO CON COMENTARIOS, PUEDE PROCEDER SUJETO
A LA INCORPORACIÓN DE LOS CAMBIOS INDICADOS
Carrera 11B #99-25, Piso 16 3. DEVUELTO Y REVISADO
Bogotá D.C. 4. SOLO PARA INFORMACIÓN
Colombia
FIRMA: LUIS FERNANDO ROJAS FECHA:
T: +57 1 794 17 93
Worley Colombia SAS
_____________ 28-07-21

© Copyright 2020 Worley ACN 096 090 158. No part of this document or the information it contains may be reproduced or transmitted in any form or by any means electronic or mechanical, including photocopying,
recording, or by any information storage and retrieval system, without permission in writing from Worley

worley.com
Disclaimer
This report has been prepared on behalf of and for the exclusive use of ECOPETROL, and is subject to and issued
in accordance with the agreement between ECOPETROL and Worley Colombia SAS. Worley Colombia SAS accepts
no liability or responsibility whatsoever for it in respect of any use of or reliance upon this report by any third
party. Copying this report without the permission of ECOPETROL or Worley Colombia SAS is not permitted.

PROJECT ECP-ULL-17070-GCH-ID06-0-INS-HD-006 – Hojas de datos - Válvulas reguladoras de presión -


INGENIERÍA DE DETALLE INYECCION DE AGUA 40 ACRES CAMPO CHICHIMENE - MOC # 3 ESTACIÓN
CHICHIMENE

Worley
Rev Description Original Review Date Approval Date
Approval

Emitido para comentarios


A 16-12-2020 N/A
del cliente
LVHG EFPR AMGS

Aprobado para
0 10-02-2021 N/A
construcción
LVHG AMGS CLOE

Aprobado para
1 construcción - 25-02-2021 N/A
Actualización
LVHG AMGS CLOE

Actualizado donde se
2 Indique (Contrato No. 2021- 28-07-2021 N/A
3037741-04)
OAAB RCGA LFRR
General 1
tag number PCV-74129 2
service 2 Blanketing gas pressure control in ATK-7406 tank inlet 3
P&ID ECP-ULL-17070-GCH-ID06-0-PRO-PID-001_1DE1 4
plant Estación Chichimene 5
unit 2 ATK-7406 6
location Field 7
instrument type Pressure Regulator. Globe Valve 8
I/O type --- 9
Hazardous Area Classification 10
hazardous class Class 1 11
hazardous gas group Division 1, GroupD 12
hazardous temperature class T2 13
Piping Data 14
pipe class A3-1FA line schedule SCH 40 15
design pressure min psig --- pipe material ASTM A106 GR. B 16
design pressure max psig 285 line orientation Horizontal 17
design temperature min °F -20 pipe insulation --- 18
design temperature max °F 100 insulation thickness in --- 19
line size in 8" line number 8"-FUG-74519-A3-1FA 20
Tank Data 21
related tank tank type 2 ATK-7406 Fixed roof tank 22
tank volume 2 42448.22 BBL 23
tank dimensions tank material 2 85 ft (d) x 42 ft (H) (see note 11) --- 24
design pressure (min/max) psig 2.5 psig / -0.1181 psig (-1.89 oz/in2) 25
design temperature (min/max) °F 210°F 26
Process Data 27
fluid name Blanketing Gas (Production Gas) 28
fluid state Gas (see composition below) 29
fluid properties --- 30
maximum dp accross the valve psi 29 31
set pressure psi 1 32
depositing/plugging expected No 33
cavitation/flashing expected No. Noise expected (see note 4) 34
Operating Conditions 35
Min Norm Max 36
flowrate 2 MMSCFD 1.3 2.4 3.2 37
upstream pressure psig 30.0 30.0 30.0 38
pressure drop psi 29 29 29 39
temperature °F 120 120 120 40
specific gravity 0.7898 0.7898 0.7898 41
dynamic viscosity cP 0.013 0.013 0.013 42
ratio of specific heats 1.32 1.32 1.32 43
compresibility factor 0.99 0.99 0.99 44
Calculated Valve Data (see note 4) 45
Min Norm Max 46
flow coefficient Cv calculated 28 69 100 47
valve travel % 20 48 69 48
sound pressure level allowable dB 85 85 85 49
sound pressure level calculated dB 92 (see note 4) 85 (see note 4) 94 (see note 4) 50
Valve Data & Options 51
selected cv 145 (see note 2) fire safe standard --- 52
calculated valve characteristic Linear fire safe design --- 53
selected valve characteristic Linear pressure registration --- 54
flow tending to Open pilot operated Yes 55
fire safe required --- 56
Blanketing gas composition: 57
Composition % Composition % Composition % Composition % 58
Nitrogen 2.2173 i-Pentane 0.4367 n-C11 0.0074 n-C18 0.0001 59
CO2 13.0273 n-Pentane 0.3491 n-C12 0.0048 n-C19 0.0001 60
Methane 75.0876 n-Hexane 0.318 n-C13 0.003 n-C20 0 61
Ethane 4.4844 n-Heptane 0.2053 n-C14 0.0013 Bencene 0.0195 62
Propane 2.0172 n-Octane 0.066 n-C15 0.0008 Toluene 0.0331 63
i-Butane 0.607 n-Nonane 0.0362 n-C16 0.0004 --- --- 64
n-Butane 1.0618 n-Decane 0.0153 n-C17 0.0002 --- --- 65

Instrument Specification
Actualizado donde se Indique (Contrato No. Self regulating control valve
2 OAAB 27-07-2021
2021-3037741-04)
1 LVHG 25-02-2021 Aprobado para construcción - Actualización
0 LVHG 10-02-2021 Aprobado para construcción Inst Chk Process Chk Approval
A LVHG 16-12-2020 Emitido para comentarios del cliente AMGS JAHR CLOE Sheet 3 of 4
No. By Date Revisión Project: ID INYECCION DE AGUA 40 ACRES - MOC # 3 ESTACIÓN CHICHIMENE Rev.: 1
Main Valve Body / Internals / Packing 1
valve type Globe bonnet type Standard 2
body material ASTM A216 GR. WCB or better bonnet material ASTM A216 GR. WCB or better 3
body size in 4 (see note 2) seat material ASTM A217 or better 4
body rating ANSI 150 leakage standard ANSI/FCI-70-2 5
process connection size in 4 (see note 2) leakage class relative Class IV 6

process connection rating ANSI 150 plug material ASTM A276 T410, T420 or better 7

process connection type Flanged, Raised Face plug size in By MFR 8


process connection standard ASME B16.5 coating system --- 9
flange finish standard 125 to 250 Ra colour topcoat --- 10
flange finish execution RF winterizing / heating N/A 11
face to face dimension in MFR std tracing temperature N/A 12
weight kg By MFR diaphragm material By MFR 13
valve orientation Horizontal tubing material 316 stainless steel 14
Actuator 15
type of actuator: Pressure reducing set point: 1 psi 16
pilot: By MFR body, spring case material: Steel 17
supply to pilot: From control line 18
spring range: 0.5 to 1.2 psig (see note 10) 19
Accesories 20
filter --- 21
Supply gauge --- 22
Line strainer --- 23
Internal relief yes 24
--- 25
Special Requirements Special Requirements 26
material inspection certificate acc. to EN10204 Yes PED category --- 27
hydrostatic pressure test report Yes PED module vendor --- 28
PED fluid group --- hydrogen service requirements --- 29
PED table --- NACE compliant materials --- 30
Purchasing Data 31
manufacturer Acoording to Ecopetrol Vendor List 32
model By MFR 33
serial no --- 34
supplier --- 35
requisition no --- 36
requisition item no --- 37
38
39
40
41
42
43
Notes: 44
1. Stud, bolts,nuts and internal trim shall be as minimum as indicated. Manufacturer shall specify and include proper internal and external parts materials to fully comply with 45
process fluid and conditions.
46
2. Vendor shall verify, confirm and submit valve sizing calculations (including valve size and Cv), according to service conditions and process data indicated herewith.
3. Intrument shall have a permantly attached nameplate in 304 S.S stamped with following information: P.O Number, Identification TAG. 47
4. Trim material shall be selected to withstand corrosion, erosion and wear under severe service conditions. Vendor shall include noise reduction element if necessary. 48
5. Valve and pilot shall be tropicalized to be suitable for operation in a corrosive, salt laden and marine atmosphere. 49
6. Spring set, materials and hydrostatic test certificates shall be delivered. 50
7. Materials according to Piping Material Class Specification A3-1F. Vendor shall guarantee proper material selection to comply with Piping Material Class Specification.
51
8. Vendor supply shall include, main ragulation valve, actuator, pilot, filters and all elements required for correct operation of valve.
9. According to Ecopetrol Vendor List latest version. 52
10. Vendor shall verify and select spring range according to valve set required. 53
11. The tank diameter was modified according to Ecopetrol request. 2 54
12. This document is generarted as update of the review No.1 elaborated by Worley. The changes are indicates in review triangles. The mistakes or problems with diferent 55
information to the indicate in review triangles isn’t responsibility of WOOD. 2 56
57
58
59
60
61
62
63
64

Instrument Specification
Actualizado donde se Indique (Contrato No. 2021- Self regulating control valve
2 OAAB 28-07-2021
3037741-04)
1 LVHG 25-02-2021 Aprobado para construcción - Actualización
0 LVHG 10-02-2021 Aprobado para construcción Inst Chk Process Chk Approval
A LVHG 16-12-2020 Emitido para comentarios del cliente AMGS JAHR CLOE Sheet 4 of 4
No. By Date Revisión Project: ID INYECCION DE AGUA 40 ACRES - MOC # 3 ESTACIÓN CHICHIMENE Rev.: 1