Está en la página 1de 1

ENVIROMUX: MONITOR AMBIENTAL Y ESTADOS DEL SISTEMA DE ENERGIA SEGURA.

COM
RECTIFICADOR REQUIERE ATENCIÓN
CLOSE

2.16
(no ethernet)
BOCA RJ45
COM
PUERTA TRASERA ABIERTA
OPEN

2.15
MEDIDA DE TENSIÓN Y
CORRIENTE 48VDC

COM
PUERTA DELANTERA ABIERTA
OPEN

2.14
COM
1

1
+

INV110 APAGADO/FALLADO
OPEN

2.13
2

2
-

-
Vin

Vin
3

COM
4

INV110 FALTA ENTRADA 110VDC


OPEN

2.12
Vin

Vin
(±60VDC MAX)

(±60VDC MAX)

COM
INV110 FALTA ENTRADA 220VAC
OPEN

2.11
ENVIROMUX-S5DC

ENVIROMUX-S5DC
(250VAC MAX)

(250VAC MAX)

COM
INV110 FALLA EN LA CARGA
CLOSE

2.10
L2 L1

L2 L1

PROCEDENTE DE LOS SSAA DE


MEDIDA DE TENSION SALIDA

COM
INV110 EN BYPASS
4

4
CPU

CPU

MEDIDA DE 220 VAC

CLOSE
Vin

Vin

2.9
3

LA ESTACION

ENTRADAS DIGITALES
220VAC SIES
2

2
-

COM
1

1
+

INV48 APAGADO/FALLADO
CLOSE

2.8
(no ethernet)
BOCA RJ45

(no ethernet)
BOCA RJ45

COM
INV48 FALTA ENTRADA 110VDC
OPEN

2.7
COM
DIAGRAMA UNIFILAR

Rele detector de tensión 110VDC


CLOSE
COM

1.16
INV48 FALTA ENTRADA 220VAC
OPEN

2.6
COM
TQ VI 110 HACIA GTYY
CLOSE
COM

1.15
INV48 FALLA EN LA CARGA
OPEN

2.5
COM
TQ V 110 HACIA GTY
CLOSE
COM

1.14
INV48 EN BYPASS
OPEN

2.4
COM
TQ IV 110 HACIA GTXXX
CLOSE
COM

DI16DOR16-E
ENVIROMUX
1.13
TQ C ATS OUT
OPEN

2.3
COM
TQ III 110 HACIA GTXX
OPEN
COM

1.12
TQ B UTE OUT

CPU
CLOSE

2.2
COM

5VDC-3A
Power
TQ II 110 HACIA GTX
CLOSE
COM

1.11
TQ A DOBLE VIA EN POSICION NO SEGURA
CLOSE

2.1
COM
TQ I INV110 IN 110VDC
CLOSE

1.10
transformador de IN 220 VAC
5
CPU

OUT 5 VDC tension


BOCAS RJ45 (no ethernet)

COM
TQ 0 GENERAL 110VDC
4

CLOSE
ENVIROMUX E-5D

1.9
3

COM

ENTRADAS DIGITALES
USO FUTURO
2
CLOSE

(no ethernet)
BOCA RJ45

1.8
1
COM
TQ 7 MEDIDA IN 220VAC TO SIES
CLOSE

1.7
Ethernet
Ethernet COM
Gestion
TQ 6 ATS IN 1 INV48
CLOSE

1.6
COM
COM
USO FUTURO TQ 5 ATS IN 2 INV110
OPEN CLOSE

1.5
COM
COM
USO FUTURO TQ 4 RECTIFICADOR ENTRADA 220VAC
OPEN OPEN

1.4
COM

ENTRADAS DIGITALES
COM

DI16DOR16-E
ENVIROMUX
USO FUTURO
OPEN CLOSE
TQ 3 INV110 ENTRADA 220VAC

1.3
COM
COM
USO FUTURO
OPEN TQ 2 INV48 ENTRADA 220VAC

CPU
CLOSE

1.2
5VDC-3A
MODEM 3G

Power
USB
COM
COM
CONEXION WAN
USO FUTURO
OPEN CLOSE
TQ 1 GENERAL SIES 220VAC

1.1
9 VDC Power 1

9 VDC Power2
COM
USO FUTURO
OPEN
transformador de IN 220 VAC

1
OUT 5 VDC tension
transformador de IN 220 VAC
OUT 9 VDC tension
transformador de IN 220 VAC
OUT 9 VDC tension
PROYECTO
Unifilar Instalación Energía Segura
RESPONSABLE FECHA N° DE LAMINA
R&TI Energía Segura xx/xx/xxxx
UBICACIÓN ESCALA 1 De 1
Sala Telecomunicaciones 1-100