Está en la página 1de 19

PROYECTO :

ACI- UPLA 2016

PROYECTISTA: ING. GUTIERREZ SILVESTRE ABEL ANDREI


DISTRITO : EL CARMEN
PROVINCIA: CHURCAMPA DEPARTAMENTO: HUANCAVELICA
FECHA: SETIEMBRE 2016

MEMORIA DE CÁLCULO - LINEA DE CONDUCCION

CUADRO 2.1
A.- POBLACION ACTUAL 366 hab. Coeficiente de crecimiento lineal por departamento ( r )
CRECIMIENTO CRECIMIENTO
B.- TASA DE CRECIMIENTO (r%) 2.50 % DEPART. ANUAL % DEPARTAMENTO ANUAL %
HAB. ( r ) HAB. ( r )
C.- PERIODO DE DISEÑO (AÑOS) 20 años Piura 3 Cusco 1.5
Cajamarca 2.5 Apúrimac 1.5
D.- POBLACION FUTURA 549 hab. Lambayeque 3.5 Arequipa 1.5
rt La Libertad 2 Puno 1.5
Pf =Pa(1+ ) Ancash 1 Moquegua 1
100
Huánuco 2.5 Tacna 4
E.- DOTACION (LT/HAB/DIA) 60 lt/hab/dia Huancavelica 2.5 Loreto 1
Pasco 2.5 San Martin 3
F.- CONSUMO PROMEDIO ANUAL (LT/SEG) Lima 2.5 Amazonas 4
Pf . D 0.38 lps. Ica 3.2 Madre de Dios 4
Qm=
864000
CUADRO 01.01 CUADRO 01.02
G.- CONSUMO MAXIMO DIARIO (LT/SEG) 0.50 lps. Periodo de diseño recomendado para Periodo de diseño recomendado según
k1 = 1.30 poblaciones rurales la población
Qmd=k 1 Qm COMPONENTE PERIODO DE POBLACIÓN PERIODO DE
como 1.33 > 0.50 ok DISEÑO DISEÑO
El valor de K1 para pob. rurales varia entre 1.2 y 1.5. Obras de captación 20 años 2,000 - 20,000 15 años
(dependiendo de la población de diseño y de la región) Conduccion 10 a 20 años Mas de 20,000 10 años
Reservorio 20 años
H.- CAUDAL DE LA FUENTE (LT/SEG) 1.33 lt/seg. Red principal 20 años
Red secundaria 10 años
I.- CONSUMO MAXIMO HORARIO (LT/SEG) 0.76 lt/seg.
k2 = 2.00 CUADRO 02.01 CUADRO 02.02
Qmh=k 2 Qm Dotación por números de habitantes Dotación según Región
POBLACIÓN DOTACIÓN REGIÓN DOTACIÓN
El valor de k2 varían desde 1 hasta 4. (habitantes) (l/hab/día) (l/hab/día)
(dependiendo de la población de diseño y de la región) Hasta 500 60 Selva 70
500 - 1000 60 - 80 Costa 60
J.- VOLUMEN DEL RESERVORIO (M3) 1000 - 2000 80 - 100 Sierra 50
VOL. ALM. = VREG. + VINCENDIO + VRESERVA. Fuente: Ministerio de Salud Fuente: Ministerio de Salud

V = 0.25 * Qmd *86400/1000 Poblacion Vol. Extincion de Incendio


< 10000 -
Vol. Reg. = 25% ( Consumo Medio Diario) 10000 < P < 100000 2 grifos (hidrantes) tmin=2horas(Q=15lt/seg)
Vol Reg. =0.25*PfxDotación 8.24 m3. > 100000 tmin.=2horas; zona resid.: 2 grifos; zona industrial:3 grifos.
Vol. Incendio = 0.00 m3 Coef. de Hanzen-Williams: Tub. de diametros comerciales
MATERIAL C Diametro D(cm)
- VRESERVA = 25 % Vol. Total. 2.75 m3 F°F° - F°G° 100 0.75 3/4" 0.75 1.905
- VRESERVA = 33 % ( Vol.Regulacion + Vol. Incendio). 2.72 m3 Concreto 110 1 1" 1 2.54
- VRESERVA = Qp x t ---------> 2 horas < t < 4 horas 4.12 m3 Acero 120 1.5 1 1/2" 1.5 3.81
-VRESERVA = 4.12 m3 Asbesto cemento 140 2 2" 2 5.08
P.V.C 140 3 3" 2.5 6.35
Vol. Almac.= 12.35 m3 4 4" 3 7.62
Vol. Almac.= 12.00 m3 (El proyectista asume un volumen razonable) 5 5" 4 10.16
6 6" 6 15.24
Calculo Linea de Conducción
2. 64
Ecuación de Hazen Williams Q=0. 0004264 CD h
f 0. 54

CÁLCULO HIDRAULICO DE LA LINEA DE CONDUCCIÓN


LONGITUD CAUDAL COTA DEL TERRENO DESNIVEL PERDIDA DIAM. DIAM. VELOC. PERDIDA PERDIDA COTA PIEZOM. PRESIÓN
TRAMO DEL CARGA UNIT. CALC. COMER. CARGA CARGA FINAL
L Qmd INICIAL FINAL TERRENO DISPONIBLE V UNITARIA tramo INICIAL FINAL
hf D D hf1 Hf1 , Hf2
(m) (l/s) (m.s.n.m) (m.s.n.m) (m) (m/m) (Pulg.) (Pulg.) (m/s) (m/m) (m/m) (m.s.n.m) (m.s.n.m) (m)
CAP. - RESERV. 398.510 0.50 3721.420 3710.500 10.92 0.027402 0.83 2 0.24 0.001699 0.68 3721.42 3720.74 10.24

CÁLCULO HIDRAULICO DE LA LINEA DE ADUCCION


LONGITUD CAUDAL COTA DEL TERRENO DESNIVEL PERDIDA DIAM. DIAM. VELOC. PERDIDA PERDIDA COTA PIEZOM. PRESIÓN
TRAMO DEL CARGA UNIT. CALC. COMER. CARGA CARGA FINAL
L Qmd INICIAL FINAL TERRENO DISPONIBLE V UNITARIA tramo INICIAL FINAL
hf D D hf1 Hf1 , Hf2
(m) (l/s) (m.s.n.m) (m.s.n.m) (m) (m/m) (Pulg.) (Pulg.) (m/s) (m/m) (m/m) (m.s.n.m) (m.s.n.m) (m)
RES. -P1 893.300 0.76 3710.500 3689.170 21.33 0.023878 0.83 2 0.24 0.001699 1.52 3710.50 3708.98 19.81
PROYECTO :
ACI- UPLA 2016

PROYECTISTA: ING. GUTIERREZ SILVESTRE ABEL ANDREI


DISTRITO : EL CARMEN
PROVINCIA: CHURCAMPA DEPARTAMENTO: HUANCAVELICA
FECHA: SETIEMBRE 2008

MEMORIA DE CÁLCULO - CAPTACIÓN


DATOS GENERALES DEL PROYECTO AFORO MANANTIAL PAMPALCO
Tiempo 3 seg.
Población Actual : 366 hab. Vol. Recip. 4 lts. Cadal de Diseño : 0.50 l/s
Población Futura : 549 hab. Caudal 5.00 lts/seg Caudal Máximo : 0.76 l/s

DISEÑO DE LA CAPTACION - MANANTIAL DE LADERA Y CONCENTRADO

PROTECCIÓN CÁM ARA CÁM ARA


CANASTILLA
DE SALIDA AFLORAMIENTO HUMEDA SECA
TUBERIA
DE SALIDA

AFLORO
0 2
1 b AFLORO
A A CANASTILLA
L DE SALIDA
0 h0 TUBERIA
TUBERÍA D E
1 2 DE SALIDA
REBOSE Y LIMPIA L

TUBERÍA DE
REBOSE Y LIMPIA

PROTECCIÓN CÁM ARA CÁMARA


AFLORAMIENTO HUMEDA SECA

PLANTA DE CAPTACIÓN ELEVACIÓN: CORTE A-A

A .- CÁLCULO DE LA DISTANCIA ENTRE EL AFLORAMIENTO Y LA CAMARA HÚMEDA (L):


MEMORIA DE CÁLCULO - CAPTACIÓN
FÓRMULA:

L = 3.33 (ho - 1.56V2 /2g)


2

ho DONDE:
ho : Se recomienda valores entre 0.40 y 0.50m.
V2 : Velocidad de salida.recommendable menor
a 0.60 m/s.
ho = 0.4 m.
Considerando: g = 9.81 m/seg2
V2 = 0.6 m/seg.

L= 1.24 m.
L= 1.20 m.
L

B .- CÁLCULO DEL ANCHO DE LA PANTALLA (b):

CÁLCULO DEL DIÁMETRO DE LA TUBERIA


DE INGRESO A LA CAPTACIÓN:

A = Qmax / Cd * V
Donde:
Cd: Coeficiente de descarga(0.6 - 0.8)
V : Velocidad de descarga ≤ 0.6m/seg.
Qmax. : Caudal máximo del manantial (m3/seg)
A : Área total de las tuberias de salida.
MEMORIA DE CÁLCULO - CAPTACIÓN
Tomando valores:
V : 0.5 m/s A= 0.00191 m2
Qmax: 0.00076 m3/s D= 4.93 cm.
Cd : 0.8 Asumiendo:
D= 2 Pulgadas

; Aasumido= 0.002 m2

NA = Area Dobtenido + 1 Donde:


Area Dasumido NA : Número de orificios
NA = 1.94 ≈ 2 Unidades

b = ( 9 + 4 NA ) * D b= 0.85 m

C .- DETERMINACION DE LA ALTURA DE LA CÁMARA HÚMEDA ( Ht ):

a Ht = A + B + H + D + E
DONDE:
A = 10.00 cm.(Mínimo)
B = 1/2 Diámetro de la canastilla.
D = Desnivel mínimo (3.00 cm)
E = Borde Libre ( 10 - 30 cm.)
H = Altura del agua que permita una velocidad determinada a la
Ht salida de la tuberia a la linea de conducción.(min 30cm.)

1 .56. V
2 Q md
H= V=
2g Ac

Qmd = 0.000496 m3/seg V = 1.739777 m/seg


MEMORIA DE CÁLCULO - CAPTACIÓN
g= 9.81 m/seg2 H = 0.240665 m.
Ac = 0.0003 m2

Por lo tanto H= 0.30 m. (altura mim. Recomendado 0.30m)


Asumiendo :
Dc = 0.75 Pulg.
E= 0.30 m.
D= 0.03 m. Ht = 0.75 m.
A= 0.10 m.
B= 0.019 m.

D .- DISEÑO DE LA CANASTILLA :

CONDICIONES:
At = 2 Ac At
N° ranura =
3 Dc < L < 6 Dc. Área de una ranura
At ≤ 0.50 * Dg * L
MEMORIA DE CÁLCULO - CAPTACIÓN
Donde :
At : Área total de las ranuras
Ag : Área de la granada.

At = 0.00057 m2

CÁLCULO DE L:
3*Dc = 5.715 cm
6*Dc = 11.43 cm

L= 0.10 m
Ag = 0.00029 m2
At = 0.00057 m2
0.5*Dg*L = 0.00598 m2

0.00598 > 0.00057 -------- OK!

N° ranuras = 16.2871

Por lo tanto :

N° ranuras = 16 Ranuras

E .- DIMENSIONAMIENTO DE LA TUBERIA DE REBOSE Y LIMPIEZA :

FÓRMULA: Donde :
Q = Caudal máximo de la fuente en m3/seg
nQ 3 /8 S = Pendiente mínima (1 - 1.5 %) m/m
D=1 . 548[ ( ] n = coeficiente de rugosidad de manning
√S D = diámetro de la tuberia en m.

Datos:
n= 0.01 PVC
S= 0.5 %
Q= 0.76 lt/seg (caudal maximo)

n*Q = 7.6E-06
√S= 0.07071
D= 0.05 m. ≈ 1.98 Pulg. Pulg. 2 Pulg.
PROYECTO :
ACI- UPLA 2016

PROYECTISTA: ING. GUTIERREZ SILVESTRE ABEL ANDREI


DISTRITO : EL CARMEN
PROVINCIA: CHURCAMPA DEPARTAMENTO: HUANCAVELICA
FECHA: SETIEMBRE 2008

DISEÑO DE RESERVORIO DE 12 M3. VALORES DE LOS COEFICIENTES (K) PARA EL CALCULO DE MOMENTOS - TAPA LIBRE Y FONDO EMPOTRADO

Nota: Para calculo de momentos, se debe tener presente la relacion b/h


Obra: Agua Potable Ingenio el resultado debe relacionarse con la aproximacion del cuadro en y=0, y=b/4 y y=b/2
Distrito : Palca tanto en momento x y momento y , en relacion a las distancias de 0, 1/4, 1/2, 3/4 y 1 tanto en x-y
Provincia : Huancavelica en la parte baja se obtendra el ancho del muro.
Departamento : Huancavelica

DATOS :

VOLUMEN (V) = 12.00 m3.


ANCHO DE LA PARED (b) = 2.50 m. y=0 y = b/4 y = b/2
ALTURA DEL AGUA (h) = 1.90 m. b/h x/h
BORDE LIBRE (B.L.) = 0.30 m. Mx My Mx My Mx My
ALTURA TOTAL (H) = 2.20 m. 0 0.000 0.025 0.000 0.014 0.000 -0.082
PESO ESPECIFICO DEL AGUA (§a) = 1,000.00 Kg/m3. ¼ 0.010 0.019 0.007 0.013 -0.014 -0.071
PESO ESPECIFICO DEL TERRENO (§t) = 1,800.00 Kg/m3. 3.00 ½ 0.005 0.010 0.008 0.010 -0.011 -0.055
CAPACIDAD DE CARGA DEL TERRENO (öt) = 2.10 Kg/cm2. ¾ -0.033 -0.004 -0.018 0.000 -0.006 -0.028
PESO ESPECIFICO DEL CONCRETO (§c) = 2,400.00 Kg/m3. 1 -0.126 -0.025 -0.092 -0.018 0.000 0.000

A) CALCULO DE MOMENTOS Y ESPESORES 0 0.000 0.027 0.000 0.013 0.000 -0.074


¼ 0.012 0.022 0.007 0.013 -0.013 -0.066
Los límites de relación de b/h son de 0.5 a 3.0 2.50 ½ 0.011 0.014 0.008 0.010 -0.011 -0.053
b/h = 1.32 ¾ -0.021 -0.001 -0.010 0.001 -0.005 -0.027
1 -0.108 -0.022 -0.077 -0.015 0.000 0.000
y=0 y = b/4 y = b/2 0 0.000 0.027 0.000 0.009 0.000 -0.060
b/h x/h ¼ 0.013 0.023 0.006 0.010 -0.012 -0.059
Mx My Mx My Mx My 2.00 ½ 0.015 0.016 0.010 0.010 -0.010 -0.049
0 0.000 185.19 0.00 61.73 0.00 -411.54 ¾ -0.008 0.003 -0.002 0.003 -0.005 -0.027
¼ 89.167 157.76 41.15 68.59 -82.31 -404.68 1 -0.086 -0.017 -0.059 -0.012 0.000 0.000
1.32 ½ 102.885 109.74 68.59 68.59 -68.59 -336.09 0 0.000 0.025 0.000 0.007 0.000 -0.050
¾ -54.872 20.58 -13.72 20.58 -34.30 -185.19 ¼ 0.012 0.022 0.005 0.008 -0.010 -0.052
1 -589.874 -116.60 -404.68 -82.31 0.00 0.00 1.75 ½ 0.016 0.022 0.010 0.009 -0.009 -0.046
¾ -0.002 0.022 0.001 0.004 -0.005 -0.027
1 -0.074 0.022 -0.050 -0.010 0.000 0.000
M = k x §a x h3 (01) 0 0.000 0.022 0.000 0.005 0.000 -0.040
¼ 0.008 0.022 0.004 0.007 -0.009 -0.044
DEL CUADRO: Mx = 589.874 Kg-m. 1.50 ½ 0.016 0.022 0.010 0.008 -0.008 -0.042
¾ 0.003 0.022 0.003 0.004 -0.005 -0.026
CALCULO DEL ESPESOR DE LA PARED: 1 -0.060 0.022 -0.041 -0.008 0.000 0.000

½ 0 0.000 0.015 0.000 0.003 0.000 -0.029


e= 6M (02) ¼ 0.005 0.015 0.002 0.005 -0.007 -0.034
ft x b 1.25 ½ 0.014 0.015 0.008 0.007 -0.007 -0.037
¾ 0.006 0.007 0.005 0.005 -0.005 -0.024
1 -0.047 -0.009 -0.031 -0.006 0.000 0.000
DONDE : 0 0.000 0.009 0.000 0.002 0.000 -0.018
ft = 0.85(F'c)^½ = 12.32 Kg/cm2. ¼ 0.002 0.011 0.000 0.003 -0.005 -0.023
F'c = 210.00 Kg/cm2. 1.00 ½ 0.009 0.013 0.005 0.005 -0.006 -0.029
Mx = 589.87 Kg-m. ¾ 0.008 0.008 0.005 0.004 -0.004 -0.020
My = 404.68 Kg-m. 1 -0.035 -0.007 -0.022 -0.005 0.000 0.000
b = 100.00 cm. 0 0.000 0.004 0.000 0.001 0.000 -0.007
¼ 0.001 0.008 0.000 0.002 -0.002 -0.011
REMPLAZANDO VALORES EN (02) TENEMOS: 0.75 ½ 0.005 0.010 0.002 0.003 -0.003 -0.017
¾ 0.007 0.007 0.003 0.003 -0.003 -0.013
e = 16.95 cm. 1 -0.024 -0.005 -0.015 -0.003 0.000 0.000
0 0.000 0.001 0.000 0.000 0.000 -0.002
PARA EL DISEÑO SE ASUME, QUE: ¼ 0.000 0.005 0.000 0.001 -0.001 -0.004
e = 20.00 cm. 0.50 ½ 0.002 0.006 0.001 0.001 -0.002 -0.009
d = 15.00 ¾ 0.004 0.006 0.001 0.001 -0.001 -0.007
1 -0.015 -0.003 -0.008 -0.002 0.000 0.000
CALCULO DEL ESPESOR DE LA LOSA DE CUBIERTA

SE CALCULA COMO LOSA ARMADA EN DOS DIRECCIONES

Espesor e = L/36 (03)

L = b + ((2*e)/2) (04)

REMPLAZANDO VALORES EN (04):


L = 2.70 m.

LUEGO EN 03:
Espesor e = 0.08 m.

ASUMIENDO PARA EL PROYECTO

Espesor e = 0.15 m.
d = 12.50
SEGÚN EL REGLAMENTO NACIONAL DE CONSTRUCCIONES, PARA LOSAS MACIZAS EN DOS DIRECCIONES 1:1

MA = MB = CW(L^2) (05)

DONDE: C = 0.036
PESO PROPIO = 0,10 x 240 = 360.00 kg/m2
CARGA VIVA = 150.00 kg/m2
PESO TOTAL = Wtotal = 510.00 kg/m2

REEMPLAZANDO EN LA ECUACION 05:


MA = MB = 133.84 kg-m.

CALCULO DEL PERALTE:

d = M ½ (06)
Rb

SIENDO:
M = MA = MB = 133.84 kg-m.
b = 100.00 cm.

R = ½ * fc * j * k (07)

n = 10.17
k = 0.365

j = 1 - k/3 (08)

(1)n = (1)n = Es/Ec = (2.1 x 10^6)/(W^1.5 * Fy * (f'c)^½)

PARA W = 2.40 Tn/m3. Tn/m3.


f'c = 175.00 kg/cm2. kg/cm2.
Fy = 4,200.00 kg/cm2. kg/cm2.

(2)k = 1/(1+fs/(nf'c))

PARA fs = 1,400.00 kg/cm2.


fc = 79.00 kg/cm2.

EN LA ECUACION 08:
j = 0.878
EN LA ECUACION 09:
R = 12.65

REEMPLAZANDO VALORES EN 06:

d = 3.25 cm.

EL ESPESOR TOTAL (e), CONSIDERANDO UN RECUBRIMIENTO DE 2.5 CM.

Recubrimiento ( r ) = 2.50 cm.

e total = d + r e total = 5.75 cm. = 0.06 m.

SIENDO: 0.06 < 0.15 m. CONFORME

PARA EL DISEÑO SE CONSIDERA:


d = 12.50 cm.
CALCULO DEL ESPESOR DE LA LOSA DE FONDO

ASUMIENDO EL ESPESOR DE LA LOSA DE FONDO Y CONOCIDA LA ALTURA

e' = 0.15 m.
h = 1.90 m.

PESO PROPIO DEL AGUA (h x §a) = 1,900.00 kg/m2.


PESO PROPIO DEL CONCRETO (e' x §c) = 360.00 kg/m2.

w = 2,260.00 kg/m2.

DEBIDO A LA ACCION DE LAS CARGAS VERTICALES ACTUANTES PARA UNA LUZ INTERNA, SE PRODUCEN
SE PRODUCEN LOS SIGUIENTES MOMENTOS:

MOMENTO DE EMPOTRAMIENTO EN LOS EXTREMOS:

M = -(W x L^2 /192) (09) M = -73.57 kg-m.

MOMENTO EN EL CENTRO:
M = W x L^2 /384 (10) M = 36.78 kg-m.

CHEQUEO DEL ESPESOR DE LA LOSA:

EL ESPESOR SE CHEQUEA POR MEDIO DEL METODO ELASTICO, CONSIDERANDO EL MAXIMO MOMENTO ABSOLUTO:

e = 6M ½
ft x b (11)

ft = 0.85(F'c)^½ = 11.24 KG/CM2.


F'c = 175.00 KG/CM2.
M = 73.57 KG-M
b = 100.00 CM

REMPLAZANDO EN LA ECUACION 11:


e = 6.27 cm.

6.27 < 15.00 cm. CONFORME

POR LO TANTO CONSIDERANDO EL RECUBRIMIENTO:


Espesort de losa para diseño e = 20.00 cm.
r = 2.50 cm.
PERALTE:
d = 12.50 cm.
B) DISTRIBUCION DE LA ARMADURA DEL RESERVORIO

As = M (12)
fs x j x d

DONDE:
M = MOMENTO MAXIMO ABSOLUTO EN KG-M.
fs = FATIGA DE TRABAJO EN KG/CM2.
j = RELACION ENTRE LA DISTANCIA DE LA RESULTANTE DE LOS ESFUERZOS DE
DE COMPRESION AL CENTRO DE LA GRAVEDAD DE LOS ESFUERZOS DE TENSION.
d = PERALTE EFECTIVO EN CM.

CALCULO DE LA ARMADURA DE LA PARED:

M+ = 589.87 kg-m.
M- = 404.68 kg-m.
fs = 900.00 kg/cm2.
n = 9.00 Valores recomendado en las Normas Sanitarias - ACI-350
e = 20.00 cm.

r = 10.00 cm.
d efectivo = 7.50
j = 0.85
k = 0.441
b = 100.00 cm.

R = ½ * fs * j * k

n = 10.50
k = 0.48

j = 1 - k/3

(1)n = (1)n = Es/Ec = (2.1 x 10^6)/(W^1.5 * Fy * (f'c)^½)

PARA W = 2.40 Tn/m3. Tn/m3.


f'c = 175.00 kg/cm2. kg/cm2.
Fy = 4,200.00 kg/cm2. kg/cm2.

(2)k = 1/(1+fs/(nf'c))

PARA fs = 900.00 kg/cm2.


f'c = 79.00 kg/cm2.

EN LA ECUACION 08:
j = 0.84
EN LA ECUACION 09:
R = 18.13

REEMPLAZANDO VALORES EN 06:

d = 0.57 cm.

RESUMEN DEL CALCULO DEL ACERO


(RESERVORIO DE 12.00 M3.)
PARED LOSA LOSA
DESCRIPCION DE DE
VERTICALHORIZONTAL CUBIERTA FONDO
Momento "M" (kg - m) 589.87 411.54 133.84 -73.57
Espesor Util "d" (cm.) 15.00 15.00 12.50 12.50
fs (kg/cm2.) 900.00 900.00 1,400.00 900.00
n 9.00 9.00 10.00 9.00
f'c (kg/cm2.) 79.00 79.00 79.00 79.00
k = 1/(1+ fs / (n x f'c)) 0.441 0.441 0.361 0.441
j = 1 - (k/3) 0.853 0.853 0.880 0.853
Area de Acero
As = (100 x M)/(fs x j x d) (cm2.) 5.12 3.57 0.87 -0.77
C 0.0015 0.0015 0.0017 0.0017
b (cm.) 100 100 100 100
e (cm.) 20.00 20.00 15.00 20.00
Cuantia Mínima
Asmín = C x b x e (cm2.) 3 3 2.55 3.4
Area Efectiva de As2. (cm2.) 5.12 3.57 2.55 3.4
Area Efectiva de Asmín2. (cm2.) 1.27 0.71 0.71 0.71
Distribución 3/8"(Aacero/Aacero total) 0.25 0.20 0.28 0.21

C) CHEQUEO POR ESFUERZO CORTANTE Y ADHERENCIA

CHEQUEO DE LA PARED

1. - ESFUERZO CORTANTE MAXIMA (V), SERA:

V = (§a x h^2) /2 (13)

REEMPLAZANDO VALORES EN LA ECUACION 13:

V = 1,805.00 kg.
ESFUERZO CORTANTE NOMINAL

v = V/(j x b x d) (14)

DATOS J = 7/8 = 0.88

POR LO TANTO:
v = 1.38 kg/cm2.

EL ESFUERZO PERMISIBLE NOMINAL EN EL CONCRETO PARA MUROS NO EXCEDERA DE:

Vmáx = 0,02 * f'c (15)

Para f'c = ### kg/cm2.

Vmáx = 3.50 kg/cm2.

1.38 < 3.50 CONFORME

2.- CHEQUEO POR ADHERENCIA


18.9645
ACI- UPLA 2016
PROYECTO :
ACI- UPLA 2016

PROYECTISTA: ING. GUTIERREZ SILVESTRE ABEL ANDREI


DISTRITO : EL CARMEN
PROVINCIA: CHURCAMPA DEPARTAMENTO: HUANCAVELICA
FECHA: SETIEMBRE 2008

PROYECTO :

Evaluado: Ing° Moises Inga Alarcon

MEMORIA DE CÁLCULO - CAMARA ROMPEPRESIÓN

REBOSE
TUB. PVC 1" TAPA METALICA

VALVULA NIVEL DE
AGUA

ENTRADA SALIDA
TUB. PVC 1" TUB. PVC 1"
SALIDA
TUB. PVC 1"
A A

PLANTA
SECCION A-A
Para determinar la altura de la cámara rompe presion, es necesario conocer la carga requerida ( H ) para que el
gasto de salida pueda fluir. Este valor se determina mediante la ecuacion experimental de Bernoulli.

HT = A + B.L. + H DONDE: A = 10.00 cm.(Mínimo)


BL= Borde libre mínimo 40 cm.
2 H = Carga de agua
1 .56 . V
H= HT = Altura total de la cámara rompe presión.
2g
Q
V =1 . 9765 .
D2
Qmd = 0.2500 lt/seg
g = 9.81 m/seg2
D = 0.75 Pulg.

V = 0.87720467 m/seg
H = 0.06118253 m.
Por lo tanto H= 0.30 m.

Asumiendo :
B.L. = 0.40 m.
A= 0.30 m.

Ht = 1.00 m.

POR LA FACILIDAD, EN EL PROCESO CONSTRUCTIVO Y EN LA INSTALACION DE ACCESORIOS,


SE CONSIDERARÁ UNA SECCION INTERNA DE 0.60 m. x 0.60 m.
PROYECTO :
ACI- UPLA 2016

PROYECTISTA: ING. GUTIERREZ SILVESTRE ABEL ANDREI

MEMORIA DE CÁLCULO - RED DE DISTRIBUCIÓN


DATOS GENERALES DEL PROYECTO:
Población Futura : 1125 hab.
Cota del Reservorio : 3916.921 m.s.n.m Caudal Máximo horario Qmh: 1.758 l/s

CALCULO DE LOS GASTOS POR TRAMO:


Qmh
Para propositos de diseño se concidera: Consumo Unitario: Qunit .=
Ecuación de Hazen Williams PoblaciónFutura
2. 64
Q=0. 0004264 CD h Qunit.: 0.001563 l/s/hab.

f 0. 54
Calculo de los gastos por tramos
Donde: D : Diametro de la tuberia (Pulg) Nº HABITANTES GASTO
Q : Caudal de diseño (l/s) TRAMO
POBLACIÓN FUTURA POR TRAMO
hf : Perdida de carga unitaria (m/Km) POR TRAMO (l/s/hab.)
C : Coefic. de Hanzen -Williams (pie^1/2/seg) A-B 122 0.191
B-C 161 0.252
Coef. de Hanzen-Williams: Tub. de diametros comerciales C-D 160 0.250
MATERIAL C Diametro D(num) C-E 157 0.245
Fierro Fundido 100 0.75 3/4" 0.75 B - CRP 100 0.156
Concreto 110 1 1" 1 CRP- F 103 0.161
Acero 120 1.5 1 1/2" 1.5 F-G 119 0.186
Asbesto cemento 140 2 2" 2 F-H 105 0.164
P.V.C 140 3 3" 2.5 H-I 98 0.153
TRAMO 1125 1.758
Coeficiente de Hanzeb-Williams: 140

RESUMEN DEL CÁLCULO HIDRAÚLICO DE LA RED DE DISTRIBUCIÓN . SISTEMA RAMIFICADO


GASTO LONGITUD DIAM. VELOC. PERDIDA DE CARGA COTA PIEZOMETRICA COTA DEL TERRENO PRESION
TRAMO (l/s) D V (m.s.n.m) (m.s.n.m) (m)
TRAMO DISEÑO L (Pulg.) (m/s) UNIT. TRAMO INICIAL FINAL INICIAL FINAL INICIAL FINAL
O/OO (m)
RES - A 1.758 60.00 2.00 0.868 17.911 1.07 2462.000 2460.925 2462.00 2443.00 0.00 17.93
A-B 0.191 1.758 125.00 2.00 0.868 17.911 2.24 2460.925 2458.686 2443.00 2432.00 17.93 26.69
B-C 0.252 0.747 97.00 1.50 0.655 14.905 1.45 2458.686 2457.241 2432.00 2430.00 26.69 27.24
C-D 0.250 0.250 67.00 0.75 0.877 57.367 3.84 2457.241 2453.397 2430.00 2424.00 27.24 29.40
C-E 0.245 0.245 105.00 0.75 0.861 55.393 5.82 2457.241 2451.424 2430.00 2434.00 27.24 17.42
B - CRP 0.156 0.820 109.00 1.50 0.720 17.729 1.93 2458.686 2456.754 2432.00 2412.00 26.69 44.75
CRP- F 0.161 0.664 98.00 1.50 0.583 11.992 1.18 2412.000 2410.825 2412.00 2392.00 0.00 18.82
F-G 0.186 0.186 86.00 1.50 0.163 1.138 0.10 2410.825 2410.727 2392.00 2369.00 18.82 41.73
F-H 0.164 0.317 100.00 1.00 0.626 21.980 2.20 2410.825 2408.627 2392.00 2385.00 18.82 23.63
H-I 0.153 0.153 120.00 0.75 0.537 23.164 2.78 2408.627 2405.847 2385.00 2372.00 23.63 33.85
1.758