Está en la página 1de 4

ZAPATA AISLADA

CALCULADO POR: ING. DENNY ZAMORA C.I.V 114.236

hf

Df
t1
S

t2

DATOS GENERALES:
SECCION DE COLUMNA t1 = 0.30 mts.
t2 = 0.30 mts.
CARGA MUERTA: PD = 20.00 Tn.
CARGA VIVA: PL = 10.00 Tn.
CAPACIDAD PORTANTE DEL SUELO: σt = 2.50 kg/cm2.
PROFUNDIDAD DE DESPLANTE: Df = 1.00 mts.
PESO ESPECIFICO DEL TERRENO: γt = 2.10 Tn/m3.
RESISTENCIA DEL CONCRETO DE LA ZAPATA: f'c = 280.00 kg/cm2.
SOBRECARGA DEL PISO: s/c = 500.00 kg/m2.
RESISTENCIA DEL ACERO: Fy = 4200.00 kg/cm2.
RECUBRIMIENTO R= 7.50 cmt
DIAMETRO DE LAS VARILLAS DE REFUERZO: Øv = 1.27 cm.

ALTURA A NIVEL DE PISO TERMINADO hf= 1.30 mts.

ESFUERZO NETO DEL TERRENO " σn ":


σn = 21.77 Tn/m2

AREA DE LA ZAPATA " Azap ":


Azap = 1.38 m2 S' x T' = 1.180 x 1.180 m2

PARA CUMPLIR Lv1 = Lv2

T= 1.180 mts. Utilizar T= 1.200 mt

S= 1.180 mts. Utilizar S= 1.200 mt

USAR SxT 1.200 x 1.200

Lv1 = Lv2 = 0.450


0.450

REACCION NETA DEL TERRENO " Wnu ":


Pu = 40 Tn
Az = 1.44 m2

Wnu = 27.78 Tn/m2

DIMENSIONAMIENTO DE LA ALTURA " h " DE LA ZAPATA POR PUNZONAMIENTO:


CONDICION DE DISEÑO:

Vc = Vu/Ø = (Pu-Wu.m.n)/Ø…. ( I )

TAMBIEN: Ø= 0.85
Vc = 1.06√(f'c)xboxd ….( II )

I = II
Formando una ecuacion de segundo Grado
Entonces d = 0.1332 mt

h = 22.09 cm usar h = 60.000 cm

dprom = 0.510 m

VERIFICACION DE CORTANTE:

Lv = 0.450 mts.
Vdu = -2.00 Tn.
Vn = -2.35 Tn.

Vc = 54.28 Tn > Vn CONFORME

SENTIDO LONGITUDINAL:
DISEÑO POR FLEXION:

Mu = 3.38 Tn-m
b= 120.00 cm
ITERANDO:
Ød = FACTOR DE REDUCCION DE DISEÑO IGUAL A 0.9ºº Ød = 0.90

Usar As = 1.76 cm2 a= 0.258

VERIFICACION DE ACERO MINIMO:


Asmin = (ρtemp).(b).(d)
Asmin = 11.02 cm2. < 1.76 cm2. USAR Asmin

As = 11.02 cm2.

CALCULO DE VARILLAS:
AØ = AREA DE LA VARILLA A USAR EN cm2. 1.27 3
AØ = cm2.
n = As/AØ = 8.67 VARILLAS

usar n = 9 VARILLAS

r = RECUBRIMIENTO EN mts. USUALMENTE 0.075m.


Øv = DIAMETRO DE LA VARILLA USADA EN mts. Øv =
Separacion = ( S -2r - Øv ) / (n - 1)
Separacion = 12.970 cm

Usar Separacion = 13 cm

USAR: 9 VARILLAS 0 @ 13 cm

SENTIDO TRANSVERSAL:
Asl = 11.02 cm2

Ast = 11.02 cm2

AØ = cm2. 3 1.27
n = As/AØ = 8.67 VARILLAS

usar n = 9 VARILLAS

r = RECUBRIMIENTO EN mts. USUALMENTE 0.075m.


Øv = DIAMETRO DE LA VARILLA USADA EN mts. Øv =

Separacion = ( S -2r - Øv ) / (n - 1)
Separacion = 12.970 mts.

Usar Separacion = 13 mts.

USAR: 9 VARILLAS @ 13 cm

LONGITUD DE DESARROLLO DEL REFUERZO

Longitud disponible para cada barra


Ld = 37.50 cm

Para barras en Traccion :


Ab = 1.27 cm2
Fc = 280.00 Kg/cm2
Fy = 4200.00 Kg/cm2
db = 1.272 cm

Ld1 = 19.13 cm
Ld2 = 30.44 cm
Ld3 = 30.00 cm

Ld = 30.443 cm
Usar Ld = 24.354 cm < Ldisp = 37.500 cm conforme

Transferencia de fuerza en la interfase de columna y cimentacion

a.- Transferencia al Aplastamiento sobre la columna


Pu = 40 Tn

Pn = 61.54 Tn

Resistencia al Aplastamiento de la columna Pnb

Pnb = 214.2 Tn
Pn < Pnb conforme

b.- Resistencia al Aplastamiento en el concreto de la Cimentacion

Pn = 61.54

Xo = 1.2 mt
A2 = 1.44 mt
A1 = 0.09 mt

(A2/A1)^0,5 = 4 usar 2.00

Ao = 0.18

Pnb = 428.4 Tn

Pn < Pnb conforme

Dowells entre columna y cimentacion

si Pn < Pnb usar Asmin = 4.50 cm2


para zonas sismicas