LAMP LAMP LAMP
127VCA
BOMBA 1HP W F E
Circuito
Potencia Fases
20W 40W 50W 180 W 373W V
C1 7 3 1 9 1930 1 127
C2 3 3 1 6 1310 1 127
C3 2 3 3 7 1570 1 127
C4 1 2 2 5 1100 1 127
C5 1 373 1 127
𝛴 5026.4
habitación Fecha:
umbrado y fuerza
are D-QOD 6
Conductor por
In If L e% S Interruptor
e% real selección
limite P-A
A 25% m mm2 Calibre
16.89 21.11 18 3 1.83 3.99 12 20
11.46 14.33 27 3 1.86 4.06 12 15
13.74 17.17 15 3 0.41 2.70 12 20
9.62 12.03 20 3 0.23 2.53 12 15
3.26 4.08 4 3 0.02 0.17 12 15
𝛴 43.98 𝛴 54.97
39.58 A alimetacion
14 15
12 20
10 30
8 40
6 65
Fases Tuberia en mm
Ubicación
A B C conduit
1930 16 ESTUDIO, BANO, CUARTO DE SERVICIO
1310 16 Y COMEDOR
COCINA Y SALA PLANTA BAJABAJA
PLANTA
RECAMARAS, BANO, VESTIDOR Y SALA
1570 16 PLANTA ALTAY BALCON PLANTA
RECAMARAS
1100 16 ALTA
373 16 BOMBA CENTRIFUGA
𝛴 5026.4 SUMA TOTAL DE CIRCUITOS
A alimetacion 1 awg 6
15
20
30
40
65
CALCULO DE CIRCUITOS ELECTRICOS
CALCULO DE LA CORRIENTE (AMP) Y SECCION TRANSVERSAL (MM2)
SISTEMA MONOFASICO
W 4 X L X I
I = ---------------- = AMPERS S = ------------------------ = mm2
V X Fp VXe%
SISTEMA BIFASICO
W 2 X L X I
I = -------------------- = AMPERS S = ------------------------ = mm2
2 X V X Fp VXe%
SISTEMA TRIFASICO
W 2 X 1,73 X L X I
I = -------------------- = AMPERS S = ------------------------ = mm2
1.73 X Vf X Fp Vf X e %
DONDE:
I = CORRIENTE (AMP)
S = SECCION TRANSVERSAL (MM2)
W = POTENCIA (WATS)
V = VOLTAJE 127 (VOLTS) AL NEUTRO
Vf = VOLTAJE 220 (VOLTS) ENTRE FACES
L = LONGITUD (METROS)
Fp = FACTOR DE POTENCIA = 0.9 NOM-001-SEDE 2012 (seguridad)/Codigo RED (Calidad)
e% = CAIDA DE TENSION (VOLTS)
NO DEBE SER MAYOR AL 3%, SEGÚN 210-19 NOTA 4 DE LA NOM-001-SEDE-2018
I=W/V
Tipos de conductores :
CAL = 12
Z = 6.00 Ohm/Km
L = 0.018 km. 18 m
I = 21.1067367 Amp.
V = 1.73 Z L I
V = 3.94 Volts
e% = 394.36 / 216.06
e% = 1.83 %
C2 Raiz de 3 = 1.73
CAL = 12
Z = 6 Ohm/Km
L = 0.027 km. 27 m
I = 14.33 Amp.
V = 1.73 Z L I
V = 4.02 Volts
e% = 401.51 / 215.98
e% = 1.86 %
C3 Raiz de 4 = 438.27
CAL = 12
Z = 6 Ohm/Km
L = 0.015 km. 15 m
I = 17.17 Amp.
V = 1.73 Z L I
V = 2.67 Volts
e% = 270.01 / 653.87
e% = 0.41 %
C4 Raiz de 5 = 874.81
CAL = 12
Z = 6 Ohm/Km
L = 0.02 km. 20 m
I = 12.03 Amp.
V = 1.73 Z L I
V = 2.50 Volts
e% = 0.23 %
C5 Raiz de 6 = 1311.4
CAL = 14
Z = 9.2 Ohm/Km
L = 0.004 km. 4m
I = 4.08 Amp.
V = 1.73 Z L I
V = 0.26 Volts
e% = 26.75 / 1529.36
e% = 0.02 %
Formula
V=√3*Z*L*If
e%=(Vx100)/(220-V)
IMPEDANCIA PARA CABLES DE 600 V, OPERANDO A 75 ´C EN UN SISTEMA TRIFASICO
A 60 HZ: 3 CABLES UNIPOLARES EN UN MISMO DUCTO
OHMS/Km, AL NEUTRO
NOTAS:
16 mm 1/2 " 0 0 0 0 0 0 0 0 0 0 0 0 0 0
21 mm 3/4 " 1 1 0 1 0 0 0 0 0 0 0 0 0 0
27 mm 1" 1 1 1 1 1 1 1 1 0 1 0 0 0 0
35 mm 1 1/4 " 1 1 1 1 1 1 1 1 1 1 1 1 1 1
- THW LS
41 mm 1 1/2 " 2 3 1 2 1 1 1 1 1 1 1 1 1 1
53 mm 2" 4 5 3 4 3 3 2 3 1 2 1 1 1 1
63 mm 2 1/2" 7 8 6 7 5 6 4 5 4 4 3 4 3 3
78 mm 3" 11 13 9 11 7 9 6 6 5 6 5 6 4 5
103 mm 3 1/2 "
TAMAÑO DE TUBO TIPO NUMERO DE CONDUCTORES