ANALISIS EXPERIMENTAL DE LAS CARACTERISTICAS

OPERATIVAS DE LOS GENERADORES DE CD AUTOEXCITADAS


1. COMPORTAMIENTO DE LA PUERTA DEL INDUCIDO, EN RÉGIMEN PERMANENTE,
PARA UN GENERADOR SERIE, TRABAJANDO A VELOCIDAD CONSTANTE.

VL IL Ea Wr τr
81.4 1.05 82.8805013 1800 1.1
80.1 0.99 81.556857 1800 1.03
73.9 0.76 75.2440915 1800 0.78
71.3 0.7 72.5968028 1800 0.72
68.2 0.64 69.44042 1800 0.66
64 0.59 65.1640305 1800 0.59
55.7 0.48 56.7130703 1800 0.48
49.6 0.43 50.5021237 1800 0.45
39.9 0.34 40.6257003 1800 0.38
29 0.25 29.5274513 1800 0.33
27.9 0.22 28.4074446 1800 0.32
20 0.16 20.3637595 1800 0.28
16.7 0.14 17.0037392 1800 0.28
14 0.12 14.2546317 1800 0.27
13.24 0.11 13.4808088 1800 0.26
9.16 0.08 9.32660187 1800 0.25
8.15 0.07 8.29823201 1800 0.25
7.71 0.07 7.8502293 1800 0.25
6.81 0.07 6.93386012 1800 0.25
6.38 0.06 6.49603929 1800 0.24

 Reacción
I L (Ra + Rs ) de Pm Pe n
armadura
40.0281   207.3456 85.47 0.41221034
37.74078   194.15088 79.299 0.40844008
28.97272   147.02688 56.164 0.38199818
26.6854   135.71712 49.91 0.36775021
24.39808   124.40736 43.648 0.35084741
22.49198   111.21264 37.76 0.33952975
18.29856   90.47808 26.736 0.29549699
16.39246   84.8232 21.328 0.25144064
12.96148   71.62848 13.566 0.18939394
9.5305   62.20368 7.25 0.11655259
8.38684   60.31872 6.138 0.10175945
6.09952   52.77888 3.2 0.06063031
5.33708   52.77888 2.338 0.04429802
4.57464   50.89392 1.68 0.03300984
4.19342   49.00896 1.4564 0.02971702
3.04976   47.124 0.7328 0.01555046
2.66854   47.124 0.5705 0.01210636
2.66854   47.124 0.5397 0.01145276
2.66854   47.124 0.4767 0.01011586
2.28732   45.23904 0.3828 0.00846172
90
80
70
60
50
Vl

40
30
20
10
0
0 0.2 0.4 0.6 0.8 1 1.2
IL

2.-COMPORTAMIENTO DE LA PUERTA DEL INDUCIDO, EN RÉGIMEN PERMANENTE, PARA


UN GENERADOR EN DERIVACION, TRABAJANDO A VELOCIDAD CONSTANTE

VL IL if(ma) Ia Wr Tr
160.7 0.05 80.4 80.45 1800 0.38
145.5 0.18 72.8 72.98 1800 0.49
143.5 0.21 71.8 72.01 1800 0.51
139.6 0.26 69.7 69.96 1800 0.54
132.9 0.33 66.3 66.63 1800 0.6
126 0.38 63 63.38 1800 0.62
123.2 0.4 61.6 62 1800 0.62
120 0.42 60 60.42 1800 0.62
115.5 0.44 57.7 58.14 1800 0.63
113.5 0.45 56.8 57.25 1800 0.62
107 0.48 53.3 53.78 1800 0.62
102.6 0.49 51.4 51.89 1800 0.61
94.5 0.5 47.3 47.8 1800 0.6
87.7 0.51 43.8 44.31 1800 0.58
80.1 0.51 40.1 40.61 1800 0.54
76.2 0.51 38 38.51 1800 0.52
71.4 0.5 36.2 36.7 1800 0.51
62.1 0.48 31.3 31.78 1800 0.45
50.3 0.43 25.7 26.13 1800 0.4
42.7 0.4 22 22.4 1800 0.37
38.9 0.39 19.7 20.09 1800 0.34
32.5 0.35 16.7 17.05 1800 0.32
27.32 0.31 13.1 13.41 1800 0.29
22.3 0.27 11.1 11.37 1800 0.27

Reacción de
(Ia.Ra) Pm Pe n
armadura
0.1121760
1295.5668   71.62848 8.035 5
1175.2699 0.2835549
2   92.36304 26.19 8
1159.6490 0.3134720
4   96.13296 30.135 9
1126.6358 101.7878 0.3565848
4   4 36.296 3
1073.0095 0.3877801
2   113.0976 43.857 1
1020.6715 116.8675 0.4096946
2   2 47.88 7
116.8675 0.4216740
998.448   2 49.28 5
116.8675 0.4312575
973.00368   2 50.4 5
118.7524 0.4279489
936.28656   8 50.82 6
116.8675 0.4370333
921.954   2 51.075 2
116.8675 0.4394719
866.07312   2 51.36 8
114.9825 0.4372315
835.63656   6 50.274 2
0.4177807
769.7712   113.0976 47.25 5
109.3276 0.4091095
713.56824   8 44.727 7
101.7878 0.4013347
653.98344   4 40.851 8
0.3964785
620.16504   98.01792 38.862 2
0.3713606
591.0168   96.13296 35.7 7
0.3514132
511.78512   84.8232 29.808 9
0.2868628
420.79752   75.3984 21.629 5
360.7296   69.74352 17.08 0.2448973
0.2367190
323.52936   64.08864 15.171 2
0.1885815
274.5732   60.31872 11.375 9
215.95464   54.66384 8.4692 0.1549324
183.10248   50.89392 6.021 0.1183049
180
160
140
120

TENSIÓN VL (v) 100


80
60
40
20
0
0 0.1 0.2 0.3 0.4 0.5 0.6
CORRIENTE DE CARGA IL (A)

3.-COMPORTAMIENTO DE LA PUERTA DEL INDUCIDO, EN RÉGIMEN PERMANENTE, PARA


UN GENERADOR COMPUESTO, TRABAJANDO A VELOCIDAD CONSTANTE.
maquina compuesta diferencial
VL IL if(ma) Wr Tr
143.6 0.05 72.7 1800 0.36
18.52 0.06 9.1 1800 0.24
17.57 0.06 8.7 1800 0.25
16.54 0.06 8.2 1800 0.24
14.15 0.06 7 1800 0.24
10.78 0.07 5.3 1800 0.24
8.9 0.07 4.3 1800 0.24
8.1 0.07 4 1800 0.23
6.84 0.06 3.4 1800 0.23
6.2 0.06 3 1800 0.23
5.3 0.06 2.6 1800 0.23
4.31 0.07 2.4 1800 0.23
4.35 0.06 2.2 1800 0.24
3.61 0.06 1.8 1800 0.23
3.16 0.06 1.6 1800 0.23
2.68 0.06 1.3 1800 0.22
1.75 0.06 0.9 1800 0.22
maquina compuesta acomulativa
VL IL if(ma) Wr Tr
166.1 0.04 83.3 1800 0.36
163.4 0.21 81.6 1800 0.55
162.9 0.22 81 1800 0.55
162.2 0.25 80.4 1800 0.58
161.4 0.29 79.9 1800 0.63
159.7 0.37 78.8 1800 0.63
157.6 0.47 77.6 1800 0.85
156.3 0.51 76.8 1800 0.89
155.1 0.54 75.9 1800 0.93
153.2 0.61 74.9 1800 1
149.8 0.73 73.1 1800 1.15
146.6 0.83 71.4 1800 1.27
143.6 0.92 69.9 1800 1.38
142.2 0.95 69.1 1800 1.43
140 1 67.8 1800 1.47

reacción de
Ia(Ra+Rs) Pm Pe n
armadura
0.0979095
3.1755626   67.85856 6.644 3
0.3309836
3.1107552   103.6728 34.314 3
0.3456837
3.087882   103.6728 35.838 3
109.3276 0.3709033
3.0650088   8 40.55 2
118.7524 0.3941475
3.0459478   8 46.806 6
118.7524 0.4975811
3.0040136   8 59.089 9
2.9582672   160.2216 74.072 0.4623097
167.7614 0.4751568
2.9277696   4 79.713 7
175.3012 0.4777717
2.8934598   8 83.754 5
2.8553378   188.496 93.452 0.4957771
0.5044692
2.7867182   216.7704 109.354 4
239.3899 0.5082837
2.7219108   2 121.678 2
260.1244 0.5078799
2.6647278   8 132.112 2
269.5492 0.5011699
2.6342302   8 135.09 5
277.0891 0.5052526
2.5846716   2 140 1
170

165

160

TENSIÓN VL (v)
155

150

145

140

135

130

125
0 0.2 0.4 0.6 0.8 1 1.2
CORRIENTE DE CARGA IL (A)

ANALISIS EXPERIMENTAL DE LAS CARACTERISTICAS OPERATIVAS


DE LOS MOTORES DE CD AUTOEXCITADAS
1. COMPORTAMIENTO EN RÉGIMEN PERMANENTE DE UN MOTOR SERIE

IL Vl wr tr
0.44 154.0 2288 0
0.54 154 2000 0.05
0.58 154.5 1886 0.1
0.63 154.3 1797 0.15
0.67 154.1 1713 0.2
0.71 154 1647 0.25
0.75 154 1591 0.3
0.79 154 1532 0.35
0.83 154 1480 0.4
0.87 154 1433 0.45
0.9 154 1387 0.5
0.94 154 1344 0.55

Pm Pe n
0 67.76 0
10.472 83.16 7.94117647
19.750192 89.61 4.53717108
28.227276 97.209 3.4437967
35.877072 103.247 2.87779895
43.11846 109.34 2.53580485
49.982856 115.5 2.31079232
56.150864 121.66 2.16666301
61.99424 127.82 2.06180445
67.528692 133.98 1.98404554
72.62332 138.6 1.90847788
77.409024 144.76 1.87006621

2500

2000

1500
Wr (rpm)

1000

500

0
0 0.1 0.2 0.3 0.4 0.5 0.6
Tr (Nm)

2. COMPORTAMIENTO EN RÉGIMEN PERMANENTE DE UN MOTOR EN DERIVACION

Vl If IL wr tr
198 97 0.38 1956 0
198.1 96.2 0.51 1933 0.05
198.1 95.8 0.53 1930 0.1
198.1 95.6 0.58 1926 0.15
198.1 95.4 0.62 1915 0.2
198.1 95.1 0.66 1908 0.25
198.1 94.7 0.71 1904 0.3
198.1 94.5 0.76 1897 0.35
198.1 94.5 0.8 1890 0.4
198.1 94.2 0.85 1883 0.45
198.1 94.1 0.9 1875 0.5
198.1 94 0.95 1868 0.55
198.1 93.9 1 1861 0.6

Pm Pe n
0 75.24 0
10.121188 101.031 9.98212858
20.21096 104.993 5.19485467
30.253608 114.898 3.79782801
40.10776 122.822 3.06230016
49.95144 130.746 2.61746208
59.816064 140.651 2.35139176
69.528844 150.556 2.1653747
79.16832 158.48 2.00181083
88.734492 168.385 1.89762736
98.175 178.29 1.81604278
107.589328 188.195 1.74919765
116.930352 198.1 1.6941709

1980
1960
1940
1920
Wr (rpm)

1900
1880
1860
1840
1820
1800
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7
Tr (Nm)

3. COMPORTAMIENTO EN RÉGIMEN PERMANENTE DE UN MOTOR COMPUESTO


MOTOR COMPUESTO acomulativo
VL Ia If IL wr tr
231.3 110.81 110.4 0.41 2010 0
231.2 108.44 108 0.44 1990 0.05
231.2 107.58 107.1 0.48 1960 0.1
231.2 107.41 106.9 0.51 1940 0.15
231.2 107.26 106.7 0.56 1915 0.2
231.2 107.09 106.5 0.59 1890 0.25
231.2 106.93 106.3 0.63 1865 0.3
231.2 106.77 106.1 0.67 1843 0.35
231.2 106.61 105.9 0.71 1820 0.4
231.2 106.44 105.7 0.74 1800 0.45
231.2 106.28 105.5 0.78 1775 0.5
231.2 106.02 105.2 0.82 1750 0.55
231.2 105.76 104.9 0.86 1730 0.6
231.2 105.59 104.7 0.89 1710 0.65
231.2 105.43 104.5 0.93 1690 0.7
231.2 105.07 104.1 0.97 1670 0.75

Pm Pe n
0 94.833 0
10.41964 47.7136 4.57919851
20.52512 110.976 1
30.47352 54.7791 1.79759673
40.10776 129.472 2
49.4802 63.1831 1.27693704
58.59084 145.656 3
67.549636 71.5359 1.05901237
76.23616 164.152 4
84.8232 78.7656 0.92858558
92.939 180.336 5
100.793 86.9364 0.86252418
108.69936 198.832 6
116.39628 93.9751 0.80737202
123.88376 215.016 7
131.1618 101.9179 0.7770395
2500

2000

1500
Wr (rpm)

1000

500

0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Tr (Nm)

MOTOR COMPUESTO sustractivo


VL Ia If IL wr tr
98.7 45.48 46.3 0.82 2040 0
98.7 45.6 46.5 0.9 1610 0.05
98.7 45.36 46.3 0.94 1466 0.1
98.7 45.02 46 0.98 1330 0.15
98.7 44.88 45.9 1.02 1220 0.2
98.7 44.74 45.8 1.06 1100 0.25
98.7 44.5 45.6 1.1 1020 0.3
98.7 44.26 45.4 1.14 930 0.35
98.7 43.93 45.1 1.17 865 0.4
98.7 43.89 45.1 1.21 795 0.45
98.7 43.66 44.9 1.24 745 0.5
98.7 43.52 44.8 1.28 700 0.55
98.7 43.49 44.8 1.31 650 0.6
98.7 43.15 44.5 1.35 600 0.65
98.7 42.92 44.3 1.38 565 0.7

Pm Pe n
0 80.934 0
8.42996 41.04 4.8683505
15.351952 92.778 1
20.89164 44.1196 2.11183038
25.55168 100.674 2
28.798 47.4244 1.64679492
32.04432 108.57 3
34.08636 50.4564 1.48025192
36.23312 115.479 4
37.46358 53.1069 1.41756073
39.0082 122.388 5
40.3172 55.7056 1.38168325
40.8408 129.297 6
40.8408 58.2525 1.42633102
41.41676 136.206 7

2500

2000

1500
Wr (rpm)

1000

500

0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Tr (Nm)
CUESTIONARIO
Generador de corriente continua.
1. Utilizando los datos de la operación en condiciones nominales del generador de CD en
todas sus configuraciones; realice una tabla calculando los valores de la eficiencia. Así
mismo indique cuál de estos tipos de generadores es el más eficiente. Explique.
serie Derivacion Compuesta acomulativa
Pe n Pe n Pe n
85.47 0.41221034 8.035 0.11217605 6.644 0.09790953
79.299 0.40844008 26.19 0.28355498 34.314 0.33098363
56.164 0.38199818 30.135 0.31347209 35.838 0.34568373
49.91 0.36775021 36.296 0.35658483 40.55 0.37090332
43.648 0.35084741 43.857 0.38778011 46.806 0.39414756
37.76 0.33952975 47.88 0.40969467 59.089 0.45758119
26.736 0.29549699 49.28 0.42167405 74.072 0.4623097
21.328 0.25144064 50.4 0.43125755 79.713 0.47515687
13.566 0.18939394 50.82 0.42794896 83.754 0.47777175
7.25 0.11655259 51.075 0.43703332 93.452 0.4957771
6.138 0.10175945 51.36 0.43947198 109.354 0.50446924
3.2 0.06063031 50.274 0.43723152 121.678 0.50828372

0.6

0.5

0.4

0.3
Pe

0.2

0.1

0
0 20 40 60 80 100 120 140
ƞ

El generador más eficiente es el generador compuesta acumulativo.


2. Con los datos obtenidos en la prueba como generador de CD en las diferentes
configuraciones (excitación independiente, serie, derivación, compuesta)
graficar las curvas de comportamiento en una sola figura, identificándolas con
su respectiva leyenda.
180
160
140
120
100
Vl

80
60
40
20
0
0 0.2 0.4 0.6 0.8 1 1.2
IL

3. Evaluar las variables de comportamiento de las configuraciones del generador


de CD e indicar cuál de estas es mejor. Explique.

El generador más eficiente es el generador compuesta acumulativo, ya que se


asemeja al comportamiento de un generador de excitación independiente. Su
control es más sencillo

4. En un cuadro, determinar la caída de tensión debido a la resistencia de


armadura y l reacción de armadura, para cada caso y explique por qué algunos
tienen mayores o menores caídas de tensión.
200
180
160
140
120
100
80
60
40
20
0
0 0.2 0.4 0.6 0.8 1 1.2
MOTOR DE CORRIENTE CONTINUA.
1. Utilizando los datos de la operación en condiciones nominales del motor de cd en
todas sus configuraciones, realice una tabla calculando los valores de la eficiencia.
Así mismo indique cuál de estos tipos de motores es el más eficiente. Explique.
serie Derivacion Compuesta acomulativa
Pe n Pe n Pe n
83.16 7.94117647 101.031 9.98212858 80.934 0
89.61 4.53717108 104.993 5.19485467 88.83 10.5374165
97.209 3.4437967 114.898 3.79782801 92.778 1
103.247 2.87779895 122.822 3.06230016 96.726 4.62989023
109.34 2.53580485 130.746 2.61746208 100.674 2
115.5 2.31079232 140.651 2.35139176 104.622 3.63296062
121.66 2.16666301 150.556 2.1653747 108.57 3
127.82 2.06180445 158.48 2.00181083 112.518 3.30096848
133.98 1.98404554 168.385 1.89762736 115.479 4
138.6 1.90847788 178.29 1.81604278 119.427 3.18781601
144.76 1.87006621 188.195 1.74919765 122.388 5

2. Con los datos obtenidos en las pruebas como generador de cd en las diferentes
configuraciones (excitación independiente, serie, derivación y compuesta) graficar
las curvas de comportamiento en una sola figura, identificándolas con su respectiva
leyenda.
2500

2000

1500
Wr (rpm)

1000

500

0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Tr (Nm

3. Evaluar las variables de comportamiento de las configuraciones del motor de cd e


indicar cuál de estas es mejor. Explique.

Las variables que se obtienen y claramente podemos observar son: velocidad rotacional
(Wr) y par rotacional (Tr).

Como se puede observar en la figura anterior, el motor compuesto acumulativo tiene el


mejor comportamiento ya que para variaciones del par rotacional la velocidad rotacional
permanece casi constante, el cual se diferencia mucho de los demás tipos de motores.

4. A partir de los diagramas que afirmaciones acerca del motor compuesto son
correctas.
a. El número de revoluciones del motor compuesto bajo carga, con
cualquier relación (30%, 70% y 100%) disminuye más que el motor
(F) en derivación.
b. Si no está sometido a carga, el motor compuesto puede embalarse
(F) del mismo modo que el motor serie.
c. Cuanto mayor sea la proporción de la excitación en serie, tanto
(V) menor es la disminución del número de revoluciones bajo carga.
d. Cuanto menor sea la proporción de la excitación en serie, tanto
(F) menor es la disminución del número de revoluciones bajo carga
e. Si se invierte la polaridad del devanado en serie, aumenta el
número de revoluciones ya que se debilita el devanado en
(F) derivación.
f. Al invertir la polaridad del devanado en serie, aumenta el número
de revoluciones ya que se potencia el campo del devanado en
(F) derivación.

CONCLUSIONES
 la curva de comportamiento correspondiente del generador serie, es muy similar al de
los demás generadores. Pero si este generador opera en vacío, no existe If, por tanto,
VL alcanza solamente el valor correspondiente del flujo remanente de la maquina
como se ve claramente en la figura. También concluimos que este generador es
pésima fuente de voltaje constante.
 De la curva correspondiente al motor serie si Tr=0 se obtiene que Wr es infinito, por
tanto, si no se conecta una carga al motor, produce un embalamiento.
 generador en derivación de la figura correspondiente concluimos que a medida que la
carga aumenta, IL también aumenta, y por esa razón la velocidad tiende a disminuir
(Wr).
 Generador compuesto diferencial si Ia aumenta, también se incrementa la caída de
tensión, por esa razón Ea tiende a disminuir. De esa manera VL disminuye
drásticamente, cuando se incrementa la carga.
 Generador compuesto acumulativo debido a la conexión del devanado de campo, el
campo magnético tiene el mismo sentido que el campo producido por el devanado
serie, por esa razón sus FMMs se suman. Por otro lado, definimos que, a mayor
corriente de carga, también aumenta la corriente del inducido.

También podría gustarte