Está en la página 1de 20

PRIMERA ETAPA DE LLENADO DE LOS TANQUES

auto primera
I1 I2 SF001 primera
Trg
S
R
Par
RS
SEGUNDA Rem = off
I6 SF005 SEGUNDA
Trg
S
R
Par
RS
Rem = off
auto sensor capasitivo
I1 I3

ENCENDIDO MANUALMENTE VX
manual Pul_VX
I7 I8 T009 M_VX
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
T009 M_VX 00:00s

auto valvula vapor VV VX


I1 Q6 Q1

sensor capasitivo

SF001 primera I3
sensor capasitivo
B1
SF005 SEGUNDA I3 Q2
ENCENDIDO MANUALMENTE B1
manual PUL_B1
I7 I9 T010 M_B1
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
T010 M_B1 00:00s

SF003
En
NIVEL DE TK1
Par
V1=100+
V2=0
V3=0 SF003
V4=0
Point=0
((100+0)+0)+0
NIVEL_TK1 comparador TK1
AI1 SF002
Ax
Ay
Par
On =0
Off =0
Gain =1.0+
Offset =0
Point=0

valvula vapor VV sensor capasitivo


Q6 T008 I3

comparador TK1 V1 TK1


SF002 SF001 primera Q3
ENCENDIDO MANUALMENTE V1
manual PUL_V1
I7 I10 T011
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
T011 00:00s

valvula vapor VV sensor capasitivo


Q6 T008 I3

comparador TK1 comparador TK2 V2 TK2


SF002 SF001 primera SF004 Q4

ENCENDIDO MANUALMENTE V2
manual PUL_V2
I7 I11 T012 M_V2
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
T012 M_V2 00:00s
SF003 NIVEL DE TK2
comparador TK2
SF004
Ax
Ay
Par
On =0
Off =0
Gain =1.0+
NIVEL_TK2 Offset =0
AI2 Point=0

sensor capasitivo comparador TK3 V3 TK3


SF005 SEGUNDA I3 SF006 Q5

sensor capasitivo valvula vapor VV


T007 I3 Q6

ENCENDIDO MANUALMENTE V3
manual PUL_V3
I7 I12 T013 M_V3
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
T013 M_V3 00:00s
SF003 NIVEL DE TK3

NIVEL_TK3 comparador TK3


AI3 SF006
Ax
Ay
Par
On =0
Off =0
Gain =1.0+
Offset =0
Point=0

VAPOR POR LAS TUVERIAS

sebo de primera

sensor capasitivo
SF001 primera I3 T008
Trg
valvula vapor VV
T Q6
Rem = off
04:17s+
00:00s
00:00s

sensor capasitivo
T008 I3

sebo de segunda

sensor capasitivo
SF005 SEGUNDA I3 T007
Trg
T
Rem = off
04:17s+
00:00s
00:00s

sensor capasitivo
T007 I3

ENCENDIDO MANUALMENTE VV
manual PUL_VV
I7 I13 T014 M_VV
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
T014 M_VV 00:00s

CONTROL DE TEMPERATURA DE LOS TANQUES DE ALMACENAMIENTO

TANQUE DEL ALMACENAMIENTO TK1


manual PUL_VV1
I7 I15 T022 M_VV1
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
T022 M_VV1 00:00s
auto CALENTAR_AUTO_TK1
I1 I14

T021 A_VV1
Trg
R
Par
Rem = off
00:00s+auto VALVULA_VV1
SF015 00:00s I1 T021 A_VV1 Q7
00:00s
00:00s

High SF020
En

Par
V1=50+
V2=0
V3=0
V4=0
SF018 SF019 Point=0
Ax
Ay
((50+0)+0)+0
Par
On =0
Off =0
Gain =1.0+
Offset =0
SF020 Point=0

AI4

SF018
Ax

Par
Gain =0.45+
Offset=-50
High Point =0 EnSF017

Par
V1=45+
V2=0
V3=0
V4=0
V4=0
SF017 SF016 Point=0
Ax
Ay ((45+0)+0)+0
Par
On =0
Off =0
Gain =1.0+
Offset =0
SF018 Point=0

SF016 SF015
S
R
Par
Rem = off

SF019

TANQUE DEL ALMACENAMIENTO TK2

manual PUL_VV2
I7 I17

T037 M_VV2
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
T037 M_VV2 00:00s

auto CALENTAR_AUTO_TK2
I1 I16 T038 A_VV2
I1 I16 T038 A_VV2
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
00:00s VALVULA_VV2
auto
SF023 I1 T038 A_VV2 Q8

High SF028
En

Par
V1=50+
V2=0
V3=0
V4=0
SF026 SF027 Point=0
Ax
Ay
((50+0)+0)+0
Par
On =0
Off =0
Gain =1.0+
Offset =0
SF028 Point=0

AI5 SF026
Ax

Par
Gain =0.45+
Offset=-50
Point =0

High SF025
En

Par
V1=45+
V2=0
V3=0
V4=0
SF025 SF024 Point=0
Ax
((45+0)+0)+0
Ax
Ay ((45+0)+0)+0
Par
On =0
Off =0
Gain =1.0+
Offset =0
SF026 Point=0

SF024 SF023
S
R
Par
Rem = off

SF027

TANQUE DEL ALMACENAMIENTO TK3

manual PUL_VV3
I7 I18 T039 M_VV3
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
T039 M_VV3 00:00s

auto CALENTAR_AUTO_TK3
I1 I19 T040 A_VV3
Trg
R
Par
Rem = off
00:00s+
00:00s
00:00s
00:00s
auto VALVULA_VV3
SF029 I1 T040 A_VV3 Q9

High
SF034
En

Par
V1=50+
V2=0
V3=0
SF032 SF033
Ax V4=0
Ay Point=0
Par
On =0 ((50+0)+0)+0
Off =0
Gain =1.0+
Offset =0
SF034 Point=0

AI6 SF032
Ax

Par
Gain =0.45+
Offset=-50
Point =0

High
SF031
En

Par
V1=45+
V2=0
V3=0
SF031
V4=0
SF030 Point=0
Ax
((45+0)+0)+0
Ay
((45+0)+0)+0
Par
On =0
Off =0
Gain =1.0+
SF032
Offset =0
Point=0

SF030 SF029
S
R
Par
Rem = off

SF033

También podría gustarte