N°15-001
ORIGINAL
Enero de 2015
4064
TABLA DE CONTENIDO
1. GENERALIDADES._______________________________________________________ 3
2. MAGNITUD DE LOS TRABAJOS EJECUTADOS. ____________________________ 4
2.1 EXPLORACION GEOTÉCNICA. ________________________________________________ 4
2.1.1 PERFORACIONES. _________________________________________________________ 4
2.1.2 ENSAYOS DE LABORATORIO. ______________________________________________ 5
2.2 CÁLCULO E INFORME TÉCNICO. ______________________________________________ 6
3. MARCO GEOLÓGICO. ___________________________________________________ 7
4. ESTRATIGRAFIA GEOTÉCNICA. ________________________________________ 13
5. NIVEL FREÁTICO.______________________________________________________ 15
6. PARÁMETROS DEL SUELO. _____________________________________________ 17
7. CAPACIDAD PORTANTE DEL SUELO. ___________________________________ 22
7.1 CIMENTACIONES SUPERFICIALES. __________________________________________ 27
7.2 CIMENTACIONES PROFUNDAS. ______________________________________________ 29
8. ALTERNATIVAS DE CIMENTACIÓN. ______________________________________ 42
9. CONCLUSIONES Y RECOMENDACIONES. _______________________________ 43
9.1 ESTRATIGRAFÍA GEOTÉCNICA. _____________________________________________ 43
9.2 NIVEL FREÁTICO. ___________________________________________________________ 43
9.3 CAPACIDAD PORTANTE DEL SUELO. ________________________________________ 43
9.4 ALTERNATIVA DE CIMENTACIÓN. ____________________________________________ 44
9.5. ESTRUCTURA DE LOSAS CANCHAS. ________________________________________ 50
9.6. ADECUACIÓN DEL TERRENO. _______________________________________________ 51
9.7. EXCAVACIONES. ____________________________________________________________ 51
9.8. PRESIONES LATERALES. ___________________________________________________ 52
9.9. DRENAJES. ________________________________________________________________ 52
9.10 PARÁMETROS DE DISEÑO SÍSMICO. ________________________________________ 52
10. LIMITACIONES. _______________________________________________________ 54
Página 1 de 54
LISTA DE ANEXOS.
Página 2 de 54
1. GENERALIDADES.
Bajo dicha condición CESCO S.A ha sido contratado por la firma ZOCALO ARQUITECTURA
S.A.S para que mediante un estudio geotécnico se investiguen y determinen las
particularidades del subsuelo en cada una de las áreas en donde se construirán los coliseos, a
fin de determinar la opción de mayor conveniencia para su cimentación, como también ofrecer
las recomendaciones que sean del caso en cuanto a los aspectos geotécnicos que infieran al
proyecto.
Página 3 de 54
2. MAGNITUD DE LOS TRABAJOS EJECUTADOS.
A fin de investigar las características del suelo en las áreas que ocuparán los coliseos se
llevaron a cabo los siguientes trabajos.
2.1.1 PERFORACIONES.
Las muestras de suelo recobradas con la cuchara partida, fueron descritas visualmente por el
inspector de perforación, quien anotó en su diario de perforación, la clasificación de campo, el
color, el cambio de estrato, la presencia de materia orgánica y demás observaciones
complementarias. El valor N correspondiente al número de golpes por pie lineal de penetración
de la cuchara dentro del suelo fue anotado en cada caso y sirvió de base para la determinación
de los parámetros de capacidad portante del suelo.
Página 4 de 54
Así mismo se ejecutaron los siguientes trabajos.
En el Anexo 1 se pueden observar los registros de perforación de cada uno de los sitios
explorados con los correspondientes valores de N. En las Figuras 1 a 3 se presenta la
localización de dichos sondeos.
Las muestras del suelo explorado, tomadas durante la ejecución de las perforaciones, fueron
debidamente etiquetadas para conocer su procedencia, como también fueron guardadas en
doble bolsa plástica para evitar la pérdida de humedad natural del suelo. Luego fueron
enviadas al laboratorio de CESCO S.A en donde, siguiendo las recomendaciones de las
normas ASTM vigentes, se sometieron a los ensayos indicados en la Tabla 1.
Página 5 de 54
Clasificación de Suelos (USCS) ASTM D 2487
CBR de campo INV 148 2007
Marco geológico.
Estratigrafía de la zona investigada.
Posición del nivel freático.
Determinación de los parámetros del suelo.
Cálculo de la capacidad portante del suelo.
Recomendaciones de cimentación.
Parámetros de diseño sísmico.
Conclusiones y recomendaciones.
Página 6 de 54
3. MARCO GEOLÓGICO.
Unidades geológicas.
Las formaciones geológicas del Cuaternario, especialmente aquellas formadas por procesos de
sedimentación reciente, son de especial importancia en la región. Comprenden los diques
naturales del río Atrato en donde se concentran los asentamientos humanos y las actividades
agrícolas, la llanura inundable (en casi toda su extensión, permanentemente a lo largo del año)
a lado y lado del mismo y del río León, con sus complejos de ciénagas y cauces abandonados;
una zona de transición entre ésta y los depósitos suavemente inclinados de los afluentes del
Atrato y del río León (abanicos y deltas como el del Riosucio, áreas bajas del Sur y del Oriente
del Golfo de Urabá). Los terrenos de estos depósitos delimitan, muy ajustadamente, la
extensión de las actividades extractivas de madera, de potrerización y colonización y del
establecimiento de cultivos permanentes. Aun cuando esto ocurre principalmente hacia el Nor-
Oriente del área, entre Puerto Lleras - Pavarandó y la zona bananera del Urabá antioqueño,
también se evidencian procesos similares de deforestación-potrerización en los depósitos de
los ríos Salaquí y Truandó y, en menor medida, en los de los ríos Domingodó, Jiguamiandó y
Murindó.
Los mapas geológicos de Antioquia y Chocó (Ingeominas, 1979 y 1994) agrupan todas las
unidades del Cuaternario en una sola, incluyendo terrazas aluviales, conos o abanicos, deltas y
los depósitos de la llanura de inundación del Atrato, de la siguiente manera:
Cuaternario.
“Q. Rocas y sedimentos no consolidados del Cuaternario. Grava, arena y limo. Depósitos
aluviales deltáicos, de terrazas, coluvios y derrubios" (Antioquia).
Página 7 de 54
Mojica (1993), incluyen dentro de las unidades del Cuaternario las “Piroclastitas claras aurífero-
platiníferas” que en otros mapas geológicos (p. ej., Ingeominas, 1994) se clasifican como rocas
del Terciario.
Qal. LLANURA ALUVIAL DEL ATRATO. Depósitos limo-arcillosos y arenosos con altos
contenidos de materia orgánica, no cementados ni consolidados. Incluye los terrenos sujetos a
inundaciones permanentes y cuasi permanentes a lado y lado del Atrato y los cursos bajos de
sus afluentes: los complejos de ciénagas y terrenos cenagosos; los cauces abandonados con
vegetación acuática o parcialmente vegetados en sus diques y orillas; los bosques de panganal
casi permanentemente inundados, y los complejos orillares (diques) del río Atrato,
periódicamente inundables. También incluye el delta mismo del Atrato y las llanuras inundables
del río León y de pequeños afluentes directos al Golfo de Urabá.
Terciario.
Página 8 de 54
SE de Bojayá y Sur del río Murrí, sobre la margen derecha del Atrato. Puede corresponder a la
siguiente unidad definida en el mapa del Chocó:
“Tms. FORMACIÓN SIERRA. Sucesión de calizas con limolitas grises oscuras, que gradan
localmente a lodolitas y areniscas arcillosas en la base, y a lodolitas con areniscas
conglomeráticas en el techo". Ocurre como dos fajas continúas.
“Tmn. FORMACIÓN NAPIPÍ. Lodolitas grises, con inclusiones de nódulos calcáreos y lentes
de caliza. En la margen oriental se observa una secuencia areno-arcillosa que aumenta de
tamaño de grano hacia el sur".
“Tmu. FORMACIÓN UVA. Calizas que gradan hacia el techo a limolitas calcáreas y arcillas.
En la base se presentan horizontes conglomeráticos". Sobre la porción Norte de esta unidad se
ha identificado la Manifestación de Calizas del río Salaquí.
“Tos. FORMACIÓN SALAQUÍ. Calizas intercaladas con chert blanco y lentes de chert negro y
arenisca. En la margen oriental se encuentra, en la base, un conglomerado polimíctico con
bloques de roca volcánica y chert en matriz arenocalcárea". Afloran sobre el piedemonte de la
Cordillera Occidental, con una prolongación en la Serranía del Darién.
“Tec. FORMACIÓN CLAVO. Lodolitas grises oscuras intercaladas con limolitas calcáreas en
capas de uno a tres centímetros, de espesor".
“Td. Diorita hornbléndica con variaciones a cuarzodiorita y monzonita. Localmente gabro". Esta
formación del mapa de Antioquia debe corresponder al Batolito de Mandé definida como de
edad Cretáceo en el mapa del Chocó:
Página 9 de 54
“KTdm. BATOLITO DE MANDÉ. Monzodioritas, monzonitas, sienitas, granodioritas y gabros.
Presenta texturas equigranulares a inequigranulares, localmente néisica. Edades K/Ar entre 34
y 61 m.a". Las edades reportadas indican que el Batolito, que también aflora en la Loma del
Cuchillo, Lomas Aisladas, Cerro Dejerre o Las Pulgas (entre la desembocadura de la Ciénaga
de Tumaradó y el río Atrato), en colinas aisladas cerca de Sautatá y sobre la Serranía del
Darién (en donde se denomina Batolito de Acandí según Ingeominas 1994: 26), debe ser de
edad Terciario, como se indica en la cartografía de Antioquia. Otros autores, por ejemplo
Toussaint (1991: 79) y Galvis & Mojica (1993: 84), consideran esta unidad como del Terciario.
A ella se asocian algunas de las mineralizaciones de metales preciosos y de cobre,
principalmente al sur de la zona de estudio.
Cretáceo.
“Kv. Rocas volcánicas extrusivas e intrusivas del Cretáceo Superior. Diabasa y basalto
espitilizados y uralitizados; toba máfica y rocas piroclásticas; intercalaciones de lidita y shale
negro". Correspondería a la siguiente formación, según el mapa del Chocó:
“Ksv. Rocas sedimentarias y volcánicas del Cretáceo Superior. Lidita negra, grauvaca, limolita,
lutita y caliza: conglomerado polimíctico con cantos de rocas volcánicas. Interestratificación de
diabasa y basalto”.
Página 10 de 54
Unidades geomorfológicas.
Cordillera Occidental: El relieve y geoformas locales dependen, según Galvis & Mojica (1993:
83-86), de las características de la estratigrafía subyacente, incluyendo:
_ Depresiones con colinas facetadas bajas y drenaje dendrítico, donde afloran rocas intrusivas
del Terciario;
_ Áreas con relieve muy abrupto, escarpes verticales e incisiones profundas, en basaltos;
_ Áreas escarpadas con planos estructurales expuestos, drenaje subangular y a veces en
enrejado, en sedimentos y metasedimentos.
Serranía del Baudó: La Serranía del Baudó, que se extiende por cerca de 350 Km desde la
porción centro-occidental de Panamá hasta el Norte del delta del río San Juán, es un espinazo
asimétrico, con pendientes suaves hacia el Oriente, sobre rocas del Terciario y empinadas
hacia la costa, sobre rocas volcánicas. Su mayor altura se presenta el SW de Bahía Solano, en
el Alto del Buey con 1,850 msnm. Esta asimetría conlleva a que las corrientes que drenan al
Pacífico sean cortas, formando pequeñas playas, sobre una costa acantilada. La divisoria de
aguas entre el Pacífico y el Atrato están controladas por fallas geológicas como la de Utría
(Galvis & Mojica, 1993: 90; Ingeominas, 1994: 28) y Los Saltos (Ingeominas, 1994: 28), las
cuales, o bién cortan las rocas volcánicas de edad Cretáceo de la Serranía, al Norte de la
Bahía de Cupica, o bién las ponen en contacto con las rocas sedimentarias del Terciario. El
acopio, procesamiento e integración de información de imágenes de radar (Intera, 1992), con la
cartografía más reciente de la zona, del DMA (IGAC, 1997) y con la geología de Ingeominas
(1979, 1994), ilustra las diferentes subunidades geomorfológicas sobre la Serranía del Baudó.
En esta última composición cartográfica se destaca, al Sur de Bojayá - Vigía del Fuerte, la
geomorfología derivada de rocas terciarias sobre relieves de colinas de hasta 200 msnm, con
un drenaje dendrítico sobre la porción más estrecha del valle aluvial reciente (Cuaternario) del
Río Atrato en su curso medio.
Página 11 de 54
Serranía del Darién: Una cadena montañosa de dirección NE, cuyas divisorias de aguas entre
el Atrato y el Chucunaque (en Panamá), así como otras corrientes menores, definen los límites
entre Panamá y Colombia. Es, junto con la Serranía del Baudó, una región poco explorada e
incluye el Parque Nacional Natural de los Katíos. Del lado panameño se localiza el Parque
Nacional Darién, “colindando en casi un 90% con la frontera colombo-panameña” (Molano &
Ramírez, 1996: 120).
Valle del Atrato: Sobre la génesis y contribuciones litológicas y tectónicas para la identificación
y clasificación de unidades geomorfológicas en la cuenca del Atrato no se dispone de unidad
de criterios entre los diversos autores. Un primer modelo para la región surgió del trabajo de
Nygren (1950), quien postuló la existencia de un gran geosinclinal, el “Geosinclinal Bolivar”,
como una cuenca sedimentaria que se extendía desde el Norte de Colombia hasta Ecuador a
lo largo del Pacífico, cuyos límites al Norte eran la Cordillera Occidental y la Serranía del
Baudó. La idea sobre este geosinclinal, que incluiría las depresiones de los ríos Atrato y San
Juán unidas por el istmo de San Pablo a través de la Quebrada de Raspadura, en donde desde
épocas de la Colonia existió comunicación fluvial entre el Atlántico y el Pacífico (Anónimo,
1822: 191), ha sido revaluada por nuevos conceptos y evidencias sobre la colisión entre los
bloques Nor Andino (o más específicamente el Bloque Chocó) y la Microplaca Panamá (p. ej.:
James, 1985; Toussaint, 1992; Meyer & Mejía, 1997), o por el levantamiento y emergencia del
Istmo Panamá (Duque-Caro, 1992: 100).
Página 12 de 54
4. ESTRATIGRAFIA GEOTÉCNICA.
Los suelos explorados son de origen sedimentario. Con base en la información de las
perforaciones y de los correspondientes análisis de laboratorio se ha determinado la
estratigrafía del lote hasta la máxima profundidad investigada en cada uno de los tres casos.
Dicha estratigrafía se describe a continuación.
En las figuras 4 y 5 se puede observar la disposición del suelo explorado a través perfiles
estratigráficos.
Página 13 de 54
En la figuras 6 y 7 se puede observar la disposición del suelo explorado a través perfiles
estratigráficos.
Coliseo Istmina:
En las figuras 8 y 9 se puede observar la disposición del suelo explorado a través perfiles
estratigráficos.
Página 14 de 54
5. NIVEL FREÁTICO.
El nivel freático (capa de agua subterránea) de ser detectado es medido por el inspector de
campo, el cual espera hasta su estabilización para reportar la profundidad a la cual aparece en
cada sondeo.
En las siguientes tablas se indica, para cada una de las áreas investigadas, a que profundidad
se detectó la presencia del nivel freático en cada uno de los sondeos ejecutados.
Profundidad del
Sondeo nivel freático
(m)
P-1 4.00
P-2 4.00
P-3 4.00
P-4 5.00
P-5 4.00
P-6 4.00
P-7 Superficial
P-8 4.50
Página 15 de 54
Tabla 3. Profundidad de nivel freático- Coliseo Menor Quibdó.
Profundidad del
Sondeo nivel freático
(m)
P-9 4.00
P-10 3.00
P-11 2.80
P-12 2.50
P-13 3.00
Página 16 de 54
6. PARÁMETROS DEL SUELO.
El suelo es de tipo sedimentario (de origen aluvial). Los parámetros (valores promedio de
humedad natural y límites de Atterberg) que definen los suelos detectados en cada uno de los
sitios investigados se indican a continuación.
Profundidad HN L.L LP IP
(m) % % % %
0.50-1.00 30,80 40,18 30,85 9,34
Página 17 de 54
Tabla 6. Promedios de Humedad Natural y Límites de Atterberg.
Coliseo Menor Quibdó
Profundidad HN L.L LP IP
(m) % % % %
0.50-1.00 36,67 51,36 36,62 14,74
Profundidad HN L.L LP IP
(m) % % % %
0.50-1.00 15,38 33,58 24,91 8,67
En las siguientes tablas se pueden observar valores de algunos parámetros que definen el
suelo para cada una de las zonas investigadas.
Página 18 de 54
Tabla 8. Parámetros del suelo.
Coliseo Mayor Quibdó.
al terreno natural. liquido. plástico. plástico. liquidez preconsolidación. efectiv a de sobre- la compresión humedo de penetración
0.5-1.0 30,80 40,18 30,85 9,34 -0,01 6,00 0,14 44,44 0,40 112,38 3
1.5-2.0 34,66 46,53 34,42 12,12 0,02 6,00 0,32 19,05 0,53 112,38 4
3,0-3,5 39,13 47,12 35,62 11,50 0,31 1,80 0,59 3,08 0,40 112,38 3
4,5-5,0 41,69 48,22 33,36 14,86 0,56 0,45 0,86 0,53 0,67 112,38 5
6,0-6,5 38,44 45,89 33,99 11,91 0,37 1,20 0,14 8,89 0,67 112,38 5
7,5-8,0 34,05 39,06 27,83 11,23 0,55 0,45 0,32 1,43 0,93 112,38 7
9,0-9,5 33,95 39,19 29,65 9,54 0,45 0,80 0,59 1,37 2,00 112,38 15
10,5-11,0 36,75 41,03 30,38 10,65 0,60 0,40 0,86 0,47 1,60 112,38 12
12,0-12,50 33,69 38,51 30,13 8,38 0,42 0,85 0,14 6,30 5,33 112,38 40
al terreno natural. liquido. plástico. plástico. liquidez preconsolidación. efectiv a de sobre- la compresión humedo de penetración
0.5-1.0 36,67 51,36 36,62 14,74 0,00 6,00 0,14 44,44 0,53 112,38 4
1.5-2.0 38,36 51,41 37,37 14,03 0,07 6,00 0,32 19,05 0,67 112,38 5
3,0-3,5 38,84 47,31 36,05 11,26 0,25 2,70 0,59 4,62 0,93 112,38 7
4,5-5,0 33,76 44,35 34,74 9,61 -0,10 6,00 0,86 7,02 1,33 112,38 10
6,0-6,5 26,35 39,80 32,09 7,71 -0,74 6,00 0,14 44,44 1,33 112,38 10
7,5-8,0 21,68 38,11 31,10 7,02 -1,34 6,00 0,32 19,05 2,93 112,38 22
9,0-9,5 17,17 38,03 30,66 7,37 -1,83 6,00 0,59 10,26 4,67 112,38 35
10,5-11,0 17,45 37,84 30,75 7,08 -1,88 6,00 0,86 7,02 6,00 112,38 48
12,0-12,50 40,40 63,93 40,15 23,79 0,01 6,00 0,14 44,44 6,00 112,38 50
Página 19 de 54
Tabla 10. Parámetros del suelo.
Coliseo Istmina.
al terreno natural. liquido. plástico. plástico. liquidez preconsolidación. efectiv a de sobre- la compresión humedo de penetración
0.5-1.0 15,38 33,58 24,91 8,67 -1,10 6,00 0,14 44,44 1,33 112,38 10
1.5-2.0 20,11 35,61 26,71 8,90 -0,74 6,00 0,32 19,05 2,00 112,38 15
3,0-3,5 16,10 33,40 24,19 9,22 -0,88 6,00 0,59 10,26 4,00 112,38 30
4,5-5,0 13,47 32,10 20,88 11,22 -0,66 6,00 0,86 7,02 6,00 112,38 50
Teniendo en cuenta que se detectaron depósitos con arenas se ha considerado que “los suelos
granulares tienen una tendencia natural a densificarse bajo carga, ya sea ésta monotónica o
cíclica. Cuando el suelo está saturado y el drenaje es lento o totalmente inexistente, esta
tendencia a la densificación causa el crecimiento de la presión de poros, en exceso de su
estado estático, y el decrecimiento correlativo del esfuerzo efectivo hasta que sobreviene la
flotación de las partículas, lo que ha recibido el nombre genérico de licuación (NRS-10; H.7.5)”.
Por este motivo se ha determinado el potencial de licuación de dichos depósitos ante el evento
de un sismo de magnitud M=7.5 en la escala de Richter y Aa=0.35 G (de acuerdo con los
requerimientos y condiciones de la NSR-10). El resultado obtenido (ver memoria de cálculo
adjunta) indica que el suelo en donde se construirá el coliseo mayor y coliseo menor resulta
potencialmente licuable ante la presencia de un evento sísmico de la magnitud que ha sido
descrita hasta la profundidad a la cual aparece la limolita.
De los ensayos de presión de expansión realizados a muestras extraídas del suelo en el área
del proyecto coliseo mayor Quibdó se obtuvieron valores de presión de expansión igual a 0
Kg/cm2.
De los ensayos de resistencia del suelo (CBR de campo) se obtuvieron los siguientes
resultados.
Página 20 de 54
Tabla 11. Resultados de CBR. Coliseos Mayor y Menor Quibdó.
CBR de campo 1 2 3 4 5 6 7
CBR corregido a 0.1” 1.10 2.00 2.70 3.10 1.90 1.80 2.50
CBR corregido a 0.2” 1.30 2.50 2.70 3.20 2.00 2.10 2.80
CBR corregido a 0.1” 2.70 3.70 3.20 4.10 2.30 2.60 2.50
CBR corregido a 0.2” 2.70 3.70 3.30 3.70 2.20 2.40 2.70
CBR de campo 1 2 3
Página 21 de 54
7. CAPACIDAD PORTANTE DEL SUELO.
Para cada uno de los sitios investigados las características geomecánicas del material se
resumen así:
Profundidad
Coliseo Consistencia del suelo
(m)
0-9 Muy Suelto
Mayor Quibdó 9-12 Densidad media
12-14 Muy denso
0-6 Muy Suelto
Menor Quibdó 6-9 Densidad media
9-14 Muy denso
0-4 De suelto a muy denso
Istmina
4-5 Muy denso
Página 22 de 54
Figura 10. Valores de N Vrs Profundidad.- Coliseo Mayor Quibdó.
Página 23 de 54
Figura 11. Valores de N Vrs Profundidad.- Coliseo Menor Quibdó.
Página 24 de 54
Figura 12. Valores de N Vrs Profundidad.- Coliseo Istmina.
Página 25 de 54
Tabla 14. Valores de N (golpes/pie) Coliseo Mayor Quibdó.
Página 26 de 54
Tabla 16. Valores de N (golpes/pie) Coliseo Istmina.
Teniendo en cuenta las particularidades del suelo (estratos débiles en los primeros metros de
profundidad), se ha calculado la capacidad portante del suelo tanto para cimentaciones
superficiales (simplemente como referencia) como para cimentación profunda.
El cálculo de la capacidad portante del suelo para cimentaciones superficiales es realizado por
el método gráfico de Schmertmann(1) con la modificación de A. Palacios(2), el cual utiliza como
patrón base el valor medio de N (golpes/pie) obtenido en el ensayo de penetración estándar.
Este método permite correlacionar el valor de N con la capacidad portante admisible a
diferentes profundidades y para relaciones D/B = 1.0 y D/B = 0.0, de tal manera que la
estructura no experimente asentamientos mayores a 2.5 cm (1”).
En las siguientes tablas se presentan los valores de capacidad de carga del suelo para
cimientos superficiales.
(1) SCHMERTMANN, John Henry “Guidelines for the design of Foundations – Florida DOT – Research
Bulletin 121 A
(2) PALACIOS, A, Ph.D –Manual de diseño de CESCO LTDA.
Página 27 de 54
Tabla 17 - Capacidad de carga para Cimientos superficiales
Coliseo Mayor Quibdó.
Página 28 de 54
Tabla 19 - Capacidad de carga para Cimientos superficiales
Coliseo Istmina.
Para calcular la capacidad a carga lateral se utilizó el método de Broms el cual, para el caso de
pilotes largos, supone una flexión del pilote gobernada por la resistencia de fluencia de la
sección del pilote.
En las siguientes tablas se indican los parámetros adoptados para el cálculo de las
capacidades de carga para pilotes de concreto prebarrenados y fundidos en sitio. Así mismo se
presenta el cálculo de los asentamientos para cada uno de los casos.
Página 29 de 54
Tabla 20 - Capacidad de carga para Pilotes llevados a 14.00 m de profundidad.
Coliseo Mayor Quibdó.
Factor de
N Ti po de Factor de fri cci ón fap capaci dad de
Prof (m) DH (m) DH*fap
(gol pes/pi e) Suel o(USC) (t/m2) punta qap
(t/m2)
Longitud del
pilote(m)= 14
Fp = Wp=
Qp = (p* F2/4)* q ap
p* F* (S(DH* fap)) (p* F2/4)* l* g conc
Página 30 de 54
Tabla 21 - Capacidad de carga para Pilotes llevados a 12.00 m de profundidad.
Coliseo Menor Quibdó.
Factor de
N Ti po de Factor de fri cci ón fap capaci dad de
Prof (m) DH (m) DH*fap
(gol pes/pi e) Suel o(USC) (t/m2) punta qap
(t/m2)
Longitud del
pilote(m)= 12
Fp = Wp=
Qp = (p* F2/4)* q ap
p* F* (S(DH* fap)) (p* F2/4)* l* g conc
Página 31 de 54
Tabla 22 - Capacidad de carga para Pilotes llevados a 5.00 m de profundidad.
Coliseo Istmina.
Factor de
N Ti po de Factor de fri cci ón fap capaci dad de
Prof (m) DH (m) DH*fap
(gol pes/pi e) Suel o(USC) (t/m2) punta qap
2
(t/m )
Longitud del
pilote(m)= 5
Fp = Wp=
Qp = (p* F2/4)* q ap
p* F* (S(DH* fap)) (p* F2/4)* l* g conc
100
Diametro Inercia Momento de Momento de Qu / Kp*δ*D 3 Resistencia
(m) (m4) Fluencia My (Ton*m) cedencia Lateral (Ton)
0,4 0,001257 13,19 84,41 44,92 5,85
0,6 0,006362 44,53 56,28 35,22 15,48 10
0,8 0,020106 105,56 42,21 29,64 30,89
1 0,049088 206,17 33,77 25,93 52,77
1,2 0,101788 356,26 28,14 23,24 81,74
1
1 10 100 1000 10000
Momento de cedencia (My / D4 *δ*Kp)
Página 32 de 54
ASENTAMIENTO DE PILOTES COLISEO MAYOR QUIBDÓ
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 15 Ton.
Resistencia del pilote por fricción: Qws: 15 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 14 m.
Área de la sección transversal del pilote: Ap: 0,13 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 119 Ton/m2
Diametro del pilote: D: 0,40 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 1,26 m.
Factor de influencia: Iws: 4,07
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 45 Ton.
Resistencia del pilote por fricción: Qws: 20 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 14 m.
Área de la sección transversal del pilote: Ap: 0,28 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 159 Ton/m2
Diametro del pilote: D: 0,60 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 1,88 m.
Factor de influencia: Iws: 3,69
Página 33 de 54
ASENTAMIENTO DE PILOTES COLISEO MAYOR QUIBDÓ
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 75 Ton.
Resistencia del pilote por fricción: Qws: 30 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 14 m.
Área de la sección transversal del pilote: Ap: 0,50 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 149 Ton/m2
Diametro del pilote: D: 0,80 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 2,51 m.
Factor de influencia: Iws: 3,46
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 115 Ton.
Resistencia del pilote por fricción: Qws: 40 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 14 m.
Área de la sección transversal del pilote: Ap: 0,79 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 146 Ton/m2
Diametro del pilote: D: 1,00 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 3,14 m.
Factor de influencia: Iws: 3,31
Página 34 de 54
ASENTAMIENTO DE PILOTES COLISEO MAYOR QUIBDÓ
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 170 Ton.
Resistencia del pilote por fricción: Qws: 45 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 14 m.
Área de la sección transversal del pilote: Ap: 1,13 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 150 Ton/m2
Diametro del pilote: D: 1,20 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 3,77 m.
Factor de influencia: Iws: 3,20
Página 35 de 54
ASENTAMIENTO DE PILOTES COLISEO MENOR QUIBDÓ
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 20 Ton.
Resistencia del pilote por fricción: Qws: 20 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 12 m.
Área de la sección transversal del pilote: Ap: 0,13 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 159 Ton/m2
Diametro del pilote: D: 0,40 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 1,26 m.
Factor de influencia: Iws: 3,92
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 40 Ton.
Resistencia del pilote por fricción: Qws: 30 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 12 m.
Área de la sección transversal del pilote: Ap: 0,28 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 141 Ton/m2
Diametro del pilote: D: 0,60 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 1,88 m.
Factor de influencia: Iws: 3,57
Página 36 de 54
ASENTAMIENTO DE PILOTES COLISEO MENOR QUIBDÓ
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 75 Ton.
Resistencia del pilote por fricción: Qws: 40 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 12 m.
Área de la sección transversal del pilote: Ap: 0,50 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 149 Ton/m2
Diametro del pilote: D: 0,80 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 2,51 m.
Factor de influencia: Iws: 3,36
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 120 Ton.
Resistencia del pilote por fricción: Qws: 50 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 12 m.
Área de la sección transversal del pilote: Ap: 0,79 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 153 Ton/m2
Diametro del pilote: D: 1,00 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 3,14 m.
Factor de influencia: Iws: 3,21
Página 37 de 54
ASENTAMIENTO DE PILOTES COLISEO MENOR QUIBDÓ
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 170 Ton.
Resistencia del pilote por fricción: Qws: 60 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 12 m.
Área de la sección transversal del pilote: Ap: 1,13 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 150 Ton/m2
Diametro del pilote: D: 1,20 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 3,77 m.
Factor de influencia: Iws: 3,11
Página 38 de 54
ASENTAMIENTO DE PILOTES COLISEO MENOR QUIBDÓ
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 12 Ton.
Resistencia del pilote por fricción: Qws: 6 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 5 m.
Área de la sección transversal del pilote: Ap: 0,13 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 95 Ton/m2
Diametro del pilote: D: 0,40 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 1,26 m.
Factor de influencia: Iws: 3,24
( Q wp Q ws ) L qwp D Qws D
s1 s2 (1 2 )I wp s3 ( )( )(1 s2 ) I ws
Ap E p Es pL Es
Resistencia del pilote por punta: Qwp : 22 Ton.
Resistencia del pilote por fricción: Qws: 8 Ton.
Magnitud ξ de acuerdo con distribución de la fricción en fuste: ξ: 0,5
Longitud del pilote: L: 5 m.
Área de la sección transversal del pilote: Ap: 0,28 m2.
Módulo de elasticidad del material del pilote: Ep: 2500000 Ton/m2
Carga puntual por área unitaria en la punta del pilote qwp: 78 Ton/m2
Diametro del pilote: D: 0,60 m.
Módulo de eslaticidad del suelo bajo la punta del pilote: Es: 10000 Ton/m2
Relación de Poisson del suelo: μ: 0,45
Factor de influencia: Iwp: 0,85
Perímetro del pilote: p: 1,88 m.
Factor de influencia: Iws: 3,01
Página 39 de 54
En las siguientes tablas se resumen las capacidades de carga para los pilotes prebarrenados y
fundidos en sitio para las tres áreas en consideración.
Página 40 de 54
En las siguientes tablas se indican los valores de reacción horizontal del suelo KH y de reacción
vertical del suelo KV.
Profundidad N KH KV
DH (m) (Ton/m3) (Ton/m3)
(m) (Golpes/pie)
0-11.50 - 11.50 - -
11.5-13.5 30 2.00 5.800 -
13.5-14.0 50 0.50 9.000 12.000
Profundidad N KH KV
DH (m) (Ton/m3) (Ton/m3)
(m) (Golpes/pie)
0.0-9.0 - 9.00 - -
9.0-10.50 30 1.50 5.800 -
10.5-12.0 50 1.50 9.000 12.000
Profundidad N KH KV
DH (m) (Ton/m3) (Ton/m3)
(m) (Golpes/pie)
0.0-2.50 - 2.50 - -
2.50-4.00 30 1.50 5.800 -
4.00-5.00 50 1.00 9.000 12.000
Página 41 de 54
8. ALTERNATIVAS DE CIMENTACIÓN.
Teniendo en cuenta las características del material de sitios en donde los suelos presentan una
consistencia muy suelta en sus estratos superficiales, además de presencia de material
potencialmente licuable, se recomienda la utilización de una cimentación profunda en cada uno
de los tres casos que aborda el presente estudio de suelos.
Los diámetros de los pilotes deben ser determinados por el ingeniero calculista de acuerdo con
los valores de carga que se han consignado en las tablas 23 (para el coliseo mayor de Quibdó),
24 (para el coliseo menor de Quibdó) y 25 (para el coliseo de Istmina).
En caso de utilizar grupos de pilotes ellos deben tener el mismo diámetro. Los pilotes se
deberán unir a la estructura por medio de elementos “dados” de comportamiento rígido (con
altura determinada por el ingeniero calculista). Así mismo se deberá conservar una separación
mínima entre pilotes de 3 veces su diámetro medido centro a centro.
Página 42 de 54
9. CONCLUSIONES Y RECOMENDACIONES.
En las áreas de construcción de los coliseos en Quibdó el suelo presenta superficialmente una
capa vegetal con espesor de 0.30 m a la que le subyacen depósitos de limos arenosos
(clasificados en su gran mayoría como limos de baja plasticidad, ML) con algunos esporádicos
depósitos de material arcilloso. Los suelos son muy débiles hasta la aparición de la limolita a
profundidades variables entre los 11 y 13 m (ver figuras 4 a 7).
En la zona del coliseo de Istmina superficialmente se detectó un relleno con espesor entre 0.40
y 2.40 m, conformado por arena gravillosa de color gris oscuro y café con presencia de
desechos. Subyaciendo el relleno el suelo natural corresponde a depósitos de material
cohesivo (limos y arcillas de baja plasticidad como ML-CL, CL-ML) y algunas gravas (GM-GC).
La presencia de la limolita (suelo muy denso) aparece entre los 2 y 4 m de profundidad (ver
figuras 8 y 9).
En la zona de los coliseos de Quibdó el nivel freático aparece generalmente entre los 3 y 4 m
de profundidad. Aun cuando en el sondeo P-7 se detectó superficialmente.
En el área del coliseo de Istmina se espera que el nivel freático aparezca después de los 4 m
de profundidad, aun cuando en el sondeo P-4 se detectó a 1.00 m.
En la zona de los coliseos de Quibdó los suelos superficiales ofrecen una muy pobre capacidad
pórtante (además de que resultan potencialmente licuables). La competencia del suelo solo
mejora después de los 11 m de profundidad.
Página 43 de 54
En el área del coliseo de Istmina el suelo en muy variable en los primeros 4 m en donde se
detectaron estratos desde muy sueltos hasta muy densos. A partir de los 4 m aparece el suelo
muy denso (capa de limolita).
Debido a las condiciones señaladas en todos los casos se calculó la capacidad portante del
suelo para cimientos profundos consistentes en pilotes de concreto prebarrenados y fundidos
en sitio llevados hasta 14 m en el caso del coliseo mayor, 12 m en el coliseo menor y 5 m en el
coliseo de Istmina. Los valores de carga para diferentes diámetros se pueden observar en las
tablas 23, 24 y 25.
Los diámetros de los pilotes deben ser determinados por el ingeniero calculista de acuerdo con
los valores de carga que se han consignado en las tablas 23 (para el coliseo mayor de Quibdó),
24 (para el coliseo menor de Quibdó) y 25 (para el coliseo de Istmina).
En caso de utilizar grupos de pilotes ellos deben tener el mismo diámetro. Los pilotes se
deberán unir a la estructura por medio de elementos “dados” de comportamiento rígido (con
altura determinada por el ingeniero calculista). Así mismo se deberá conservar una separación
mínima entre pilotes de 3 veces su diámetro medido centro a centro.
Página 44 de 54
De acuerdo con la NSR-10 numeral H.8.4.2 a continuación de citan algunos de los aspectos a
tener en cuenta en el proceso constructivo de cimentaciones con pilotes o pilas.
En cualquier tipo de pila, será necesario construir una guía antes de iniciar la
perforación a fin de preservar la seguridad del personal y al calidad de la pila por
construir.
“Respecto a la localización en planta de las pilas se aceptará una tolerancia del 10% de
su diámetro. La tolerancia en la verticalidad de una pila será del 2% de su longitud hasta
25 m de profundidad y del 3% para una mayor profundidad”.
Página 45 de 54
Además de las recomendaciones anteriormente citadas, también se recomienda tener en
cuenta las siguientes recomendaciones.
EXCAVACIÓN.
1. Posicionamiento de la pala:
La pala se ubica con las orugas tangentes al pilote, para darle mayor estabilidad. La
pluma debe tener un ángulo de 75 grados respecto a la horizontal. La pala debe quedar
completamente nivelada para asegurar la verticalidad de los elementos; la nivelación se
hace utilizando madera debajo de las orugas.
2. Proceso de Excavación.
Los equipos de pilotaje de rotación consisten en un motor capaz de transmitir giro a una
barra de perforación telescópica a la cual se le acoplan las herramientas de perforación;
todo esto montado sobre una pala-grúa o un camión.
La excavación se realiza por medio de baldes que poseen tapas especiales que evitan
la pérdida de finos durante el proceso de llevar el balde hasta la superficie; la pérdida de
material de excavación incrementa el peso específico del lodo, especialmente el del
fondo de la excavación, dificultando la colocación del concreto. Los baldes son
ligeramente troncocónicos para minimizar la superficie de contacto entre el balde y las
paredes de la excavación, pues en el momento de la extracción del balde, barra y balde
trabajan como el émbolo de un pistón, causando deformaciones y derrumbes en las
Página 46 de 54
paredes del pilote y pérdida del material excavado. La forma cónica también facilita el
proceso de descarga del balde, acelerando el proceso de excavación.
Página 47 de 54
LODO BENTONITICO DE PERFORACIÓN.
LAS ARMADURAS.
1. Elaboración de la parrilla:
2. Elementos constructivos:
Página 48 de 54
Para centrar las armaduras con la excavación y garantizar el adecuado
recubrimiento del hierro, se instala en las parrillas un cierto número de
separadores de cemento denominados panelas.
EL HORMIGONADO.
1. Proceso de limpieza del hueco para asegurar que el fondo de la excavación está
completamente limpio y exento de depósitos provenientes de la decantación.
3. Vaciado del concreto por medio del sistema TREMIE (o vaciado bajo agua o lodos).
Se utilizan tubos sumergidos roscados o con soga, de longitudes entre 1 y 5 m y
diámetros entre 15 y 25 cm. Las secciones de tubería se ensamblan una después
de otra hasta alcanzar la profundidad de la excavación, dejando 50 cm entre el
extremo inferior de la tubería y el fondo; en el extremo superior se coloca el embudo
para introducir el hormigón. A través de este sistema el hormigón llega al fondo del
hueco y debido a su mayor densidad desplaza el lodo bentonitico hacia arriba.
Página 49 de 54
prolongadas en el vaciado no solo formarán juntas sino que entorpecerán
notablemente la colocación del resto de la mezcla; más de dos (2) horas de
interrupción en el proceso de hormigonado, traerá como posible consecuencia el
taponamiento de la tubería. Es condición importante que la velocidad de vaciado sea
por lo menos de 15 m3/hora.
La estructura de las canchas (en los 3 casos) puede consistir en una losa de concreto (MR-42
Kg/cm2) de 0.15 m de espesor fundida sobre una capa de material granular tipo base INVIAS
(BG-2) de 0.20 m compactada al 100% de su máxima densidad determinada en ensayo de
proctor modificado. Considerando las pobres condiciones del suelo se recomienda hacer un
mejoramiento consistente en un pedraplen (cantos rodados diámetro 4”) de 0.50 m de espesor
y una capa de material granular seleccionado de 0.30 m de espesor compactado al 95% de su
proctor modificado. Las características de dicho material se presentan a continuación.
Se recomienda que entre el pedraplen y el reemplazo del material seleccionado se instale una
geomalla triaxial.
La losa de concreto debe modularse en paños de sección cuadrada que no excedan los 3.00 m
de lado. Así mismo se debe garantizar el correcto sellado de las juntas (se puede utilizar silicón
y sellos plásticos no adherentes de polietileno).
Página 50 de 54
Figura 13. Estructura losa de concreto.
En los casos en donde se requiera alcanzar niveles arquitectónicos una vez retairada la capa
vegetal (en el caso de Quibdó) se recomienda conformar un pedraplen de 0.50 m de espesor y
una capa de material granular seleccionado (con iguales especificaciones que en el ítem
anterior) con espesor variable (mínimo de 0.20 m) hasta alcanzar el nivel deseado, dejando
una geomalla triaxial entre las dos capas.
9.7. EXCAVACIONES.
Página 51 de 54
9.8. PRESIONES LATERALES.
9.9. DRENAJES.
En los muros de contención se debe establecer un sistema de drenaje a fin de captar posibles
aguas subterráneas, esto se puede lograr mediante la instalación de un geodrén suministrado
por el mercado.
En las zonas de las canchas el pedraplen anteriormente recomendado hará también las veces
de drenaje. Ello se puede complementar con la instalación de un drenaje (tipo espina de
pescado), el cual capture y conduzca las aguas subterráneas hasta una estación de bombeo
permanente.
Para evaluar la interacción entre suelo y estructura ante un evento sísmico (de acuerdo a las
condiciones de la NSR-10) se pueden emplear los siguientes parámetros:
Página 52 de 54
Coeficientes de aceleración:
Coeficiente Fa, para la zona de periodos cortos del espectro: Fa= 1.00
Cofieficiente Fv, para la zona de periodos intermedios del espectro: Fv= 2.60
Coliseo Istmina:
Coeficientes de aceleración:
Coeficiente Fa, para la zona de periodos cortos del espectro: Fa= 1.10
Cofieficiente Fv, para la zona de periodos intermedios del espectro: Fv= 1.60
En todos los casos se deben seguir todas las recomendaciones dadas por la Norma
Colombiana de Diseño y Construcción Sismo Resistente NSR-10.
Página 53 de 54
10. LIMITACIONES.
Las recomendaciones dadas en este informe están basadas en las características del proyecto
y del subsuelo encontrado, cualquier cambio a las condiciones planteadas en el presente
informe debe ser reportado a la mayor brevedad a nuestra compañía, para dar las
recomendaciones adicionales que sean del caso.
Página 54 de 54
ANEXO 1-A
REGISTROS EXPLORATORIOS
DE PERFORACIÓN.
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-1
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-1
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-2
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-2
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-3
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-3
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-4
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 5.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-4
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 5.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-5
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-5
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-6
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-6
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-7
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : Superficial
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-7
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : Superficial
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-8
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.50 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO SONDEO: P-8
LOCALIZACION : Ver. Figura 1 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.50 mt
ANEXO 2-A
RESULTADOS DE LOS
ENSAYOS DE LABORATORIO.
CESCO S.A
DATOS ENSAYOS DE LABORATORIO
OBRA: COLISEO MAYOR - QUIBDO CLIENTE : ZOCALO ARQUITECTURA SAS N. OBRA 15-001 FECHA ene-15
DEO TRA didad(m) /pie) casagrande)P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R.
1 1 0.5-1.0 4 22 221.90 179.30 35.60 83.90 63.50 14.83 27.80 24.80 14.55 27.40 24.24 14.82
2 1.5-2.0 4 25 230.90 183.40 42.40 69.40 53.92 14.82 26.80 24.10 15.16 26.60 23.81 14.62
3 3.0-3.5 3 25 99.10 76.40 13.91 76.50 56.60 14.07 28.80 25.30 15.22 27.60 24.25 14.63
4 4.5-5.0 6 24 101.6 76.30 14.43 69.90 52.10 14.83 27.10 23.73 14.16 27.40 24.07 14.63
5 6.0-6.5 3 25 104.30 80.10 14.47 70.40 52.68 14.84 26.90 23.67 14.36 27.30 24.14 15.04
6 7,5-8,0 11 22 128.50 101.20 14.26 85.70 66.40 16.63 28.10 25.40 15.01 27.60 24.97 14.88
7 9,0-9,5 45 24 111.80 88.90 14.09 69.40 53.83 14.63 26.80 23.91 14.16 26.50 23.63 13.96
8 10,5-11,0 17 25 167.00 143.80 43.20 67.90 52.84 13.86 26.60 23.75 14.08 27.20 24.60 15.81
2 1 0.5-1.0 3 25 155.30 128.30 43.50 68.40 53.56 15.33 26.90 23.89 14.08 27.30 24.49 15.33
2 1.5-2.0 3 24 171.60 144.40 44.40 70.40 54.92 14.08 27.40 24.57 15.24 27.60 24.80 15.63
3 3.0-3.5 4 26 97.80 74.70 13.61 69.80 51.99 14.19 26.90 23.68 14.55 26.60 23.49 14.65
4 4.5-5.0 5 25 100.3 76.00 15.05 71.40 51.71 14.42 26.50 23.33 14.44 26.60 22.91 13.67
5 6.0-6.5 4 26 98.00 74.50 13.50 68.40 51.13 14.63 26.30 23.09 13.82 26.60 23.38 14.06
6 7,5-8,0 12 25 270.20 229.80 38.30 65.40 51.75 14.08 26.90 24.14 14.76 26.70 23.89 14.38
7 9,0-9,5 20 24 103.00 82.30 15.14 68.10 52.94 14.19 27.40 24.40 13.94 27.60 24.81 15.09
8 10,5-11,0 13 25 92.50 71.80 14.98 72.80 51.41 13.96 26.90 24.31 15.38 27.20 24.60 15.63
9 12,0-12,5 +50 25 83.90 68.70 13.86 68.30 53.13 14.05 26.60 23.80 14.30 27.20 24.37 14.82
3 1 0.5-1.0 3 26 257.60 205.70 38.20 69.40 54.55 14.86 26.60 23.94 14.65 26.80 24.14 14.84
2 1.5-2.0 4 24 90.50 71.20 14.61 68.80 51.06 14.44 27.40 23.97 14.29 26.90 23.56 14.12
3 3.0-3.5 4 25 100.20 75.00 15.04 70.60 52.24 14.52 27.10 23.65 14.12 27.50 24.52 16.32
4 4.5-5.0 6 24 105.7 78.10 14.80 68.70 51.38 15.24 26.40 23.18 14.16 26.30 23.02 13.88
5 6.0-6.5 7 27 116.70 87.80 14.52 69.80 51.79 14.91 27.20 24.07 14.37 26.80 23.49 14.32
6 7,5-8,0 8 25 291.70 237.20 43.10 71.40 55.51 15.62 26.60 23.81 14.24 26.80 24.07 14.69
7 9,0-9,5 23 24 112.40 90.10 15.68 72.30 56.11 14.17 26.60 24.13 15.30 26.80 24.14 14.94
8 10,5-11,0 13 25 100.50 77.20 16.66 69.10 53.69 15.00 27.70 24.70 14.91 27.40 24.59 15.41
9 12,0-12,5 +50 24 107.10 82.20 14.68 67.40 52.46 15.41 26.70 23.78 14.66 26.90 23.83 14.22
10 13,5-14,0 +50 25 233.60 192.70 38.40 69.10 54.07 14.31 27.10 24.19 14.63 26.80 23.87 14.24
Hoja: Calculo
Página 1 de 6 Archivo:Clasif-USCS COLISEO MAYOR
CESCO S.A
DATOS ENSAYOS DE LABORATORIO
OBRA: COLISEO MAYOR - QUIBDO CLIENTE : ZOCALO ARQUITECTURA SAS N. OBRA 15-001 FECHA ene-15
DEO TRA didad(m) /pie) casagrande)P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R.
4 1 0.5-1.0 4 25 269.20 214.90 37.10 72.60 56.35 14.50 26.60 23.66 14.08 26.80 23.84 14.22
2 1.5-2.0 6 26 97.00 74.80 14.35 66.80 49.36 14.01 26.60 23.45 14.78 26.80 23.48 14.36
3 3.0-3.5 5 24 291.30 238.60 40.50 67.70 52.41 14.86 26.40 23.56 15.16 26.80 24.14 16.27
4 4.5-5.0 6 25 261.9 202.30 42.50 68.20 52.62 15.18 26.90 23.80 14.74 26.30 24.15 14.94
5 6.0-6.5 7 25 130.20 97.90 14.06 69.80 52.72 13.84 27.60 24.20 14.17 27.70 23.94 14.36
6 7,5-8,0 10 24 214.50 178.50 26.20 65.80 51.69 14.38 26.60 23.89 14.63 26.40 23.66 14.32
7 9,0-9,5 23 25 138.60 111.00 16.75 69.10 53.64 14.63 27.40 24.43 15.10 26.90 23.99 14.40
8 10,5-11,0 13 24 100.20 78.00 14.12 70.80 55.11 14.81 27.60 25.06 16.83 26.40 23.62 14.61
9 12,0-12,5 +50 25 90.10 71.50 14.39 69.40 53.95 14.16 26.60 23.95 14.63 26.40 23.69 14.22
10 13,5-14,0 +50 26 89.20 70.60 15.22 71.20 55.35 14.84 26.70 24.16 15.58 26.30 23.59 14.42
5 1 0.5-1.0 3 24 101.10 80.10 14.44 67.70 52.29 14.53 27.40 24.53 14.74 26.80 24.40 16.22
SH 2 1.5-2.0 5 25 283.80 224.60 44.30 74.10 54.50 11.92 28.00 24.70 14.30 29.50 26.25 16.05
3 3.0-3.5 3 25 106.30 80.50 15.28 72.40 53.53 14.65 26.30 23.10 14.16 26.60 23.36 14.29
4 4.5-5.0 7 26 94.5 71.10 14.55 68.90 51.13 14.94 23.40 23.26 14.63 26.70 23.38 14.24
5 6.0-6.5 4 25 114.20 85.60 15.10 70.40 51.43 14.83 26.80 23.54 14.92 26.60 23.38 14.86
6 7,5-8,0 2 24 103.30 72.80 15.00 68.40 52.14 14.16 26.40 23.46 14.46 26.30 23.55 15.16
7 9,0-9,5 3 25 108.70 78.20 15.01 71.20 54.79 15.63 26.80 23.89 14.87 26.60 23.63 14.38
8 10,5-11,0 14 24 113.50 84.40 15.91 68.40 52.85 14.74 26.80 23.96 15.08 26.30 23.47 14.65
9 12,0-12,5 45 26 199.50 169.20 37.20 69.40 54.14 13.78 26.80 23.98 15.22 26.70 23.61 13.96
10 13,5-14,0 +50 24 206.80 177.80 36.80 69.10 54.49 14.92 26.80 23.86 14.22 26.40 23.59 14.38
6 1 0.5-1.0 2 24 257.70 214.70 38.50 69.40 54.26 14.65 26.80 23.77 13.63 26.60 23.98 15.16
2 1.5-2.0 5 25 107.40 82.60 15.21 71.40 52.83 14.80 27.10 23.68 14.19 26.60 23.28 14.06
3 3.0-3.5 3 25 109.60 79.30 10.84 68.10 50.83 15.31 26.80 23.56 14.62 26.40 23.47 15.36
4 4.5-5.0 5 26 101.1 76.50 13.95 69.40 51.30 14.44 27.10 23.80 14.85 27.80 24.29 14.74
5 6.0-6.5 5 26 220.20 167.70 37.20 68.40 52.96 14.00 26.70 23.90 14.18 26.40 23.77 14.64
6 7,5-8,0 3 25 109.50 80.80 16.56 67.40 52.00 14.18 26.60 23.53 14.38 26.70 23.86 14.65
7 9,0-9,5 3 24 113.90 83.70 14.44 72.20 55.85 14.68 26.60 23.76 14.23 26.80 24.22 15.63
8 10,5-11,0 14 25 187.10 146.60 37.10 69.90 55.10 15.96 26.80 23.99 15.28 26.40 23.58 14.82
9 12,0-12,5 48 25 107.70 81.30 14.83 69.70 54.37 14.67 26.80 23.98 14.36 26.40 23.64 14.24
10 13,5-14,0 +50 25 200.90 163.90 38.10 68.80 54.20 15.16 26.30 23.49 13.94 26.60 23.99 15.16
Hoja: Calculo
Página 2 de 6 Archivo:Clasif-USCS COLISEO MAYOR
CESCO S.A
DATOS ENSAYOS DE LABORATORIO
OBRA: COLISEO MAYOR - QUIBDO CLIENTE : ZOCALO ARQUITECTURA SAS N. OBRA 15-001 FECHA ene-15
DEO TRA didad(m) /pie) casagrande)P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R.
7 1 0.5-1.0 3 24 284.70 226.30 42.30 68.40 53.61 15.81 26.30 23.57 14.65 26.60 23.68 14.16
2 1.5-2.0 3 25 103.70 78.20 14.53 75.60 54.40 14.41 28.60 24.40 13.35 27.80 24.08 14.36
3 3.0-3.5 3 26 105.40 78.00 15.91 70.40 52.45 14.19 26.80 23.60 14.63 26.60 23.45 14.63
4 4.5-5.0 2 25 108.7 77.90 14.91 69.40 51.81 15.63 26.70 23.50 14.81 26.60 23.37 14.65
5 6.0-6.5 2 26 107.30 82.80 14.38 69.40 51.40 14.62 26.60 23.54 15.18 26.70 23.92 16.32
6 7,5-8,0 6 25 110.00 84.50 14.74 68.30 52.97 14.29 23.60 23.80 14.84 26.90 23.97 14.63
7 9,0-9,5 4 24 316.10 256.10 36.90 70.40 55.04 14.32 26.80 23.92 13.94 26.60 23.91 14.63
8 10,5-11,0 11 25 110.10 76.30 15.69 68.80 53.56 14.08 26.60 23.87 14.63 26.40 23.79 14.92
9 12,0-12,5 27 24 108.50 78.80 14.11 68.40 53.82 14.86 26.80 23.91 14.19 26.60 23.74 14.08
10 13,5-14,0 +50 25 275.70 221.90 44.40 69.80 54.75 14.94 26.90 23.99 14.52 26.70 23.75 14.12
8 1 0.5-1.0 4 24 99.50 77.30 14.32 69.70 52.13 15.22 27.40 23.90 14.08 26.80 23.61 14.63
2 1.5-2.0 5 25 93.30 72.50 14.50 71.40 52.72 14.84 27.60 24.04 14.38 27.80 24.42 15.26
3 3.0-3.5 5 26 100.80 75.60 16.05 68.30 50.71 14.84 27.40 23.93 14.65 27.60 23.82 13.63
4 4.5-5.0 8 25 108.6 81.10 16.05 65.50 48.99 15.16 26.60 23.27 14.16 26.40 23.08 14.00
5 6.0-6.5 8 24 304.30 231.70 38.40 67.70 52.80 14.52 26.80 24.07 14.53 26.60 23.94 14.65
6 7,5-8,0 11 25 133.60 103.20 14.32 72.80 56.97 14.88 26.60 23.90 14.63 26.80 24.20 15.33
7 9,0-9,5 7 26 320.70 254.30 44.70 69.40 54.19 14.08 26.70 23.95 14.24 26.40 23.95 15.28
8 10,5-11,0 7 25 216.70 179.80 38.10 65.80 51.88 14.16 26.40 23.73 14.63 26.80 24.00 14.42
9 12,0-12,5 38 25 268.80 216.90 44.20 67.40 52.77 14.19 26.80 23.95 14.36 26.60 23.86 14.64
10 13,5-14,0 +50 26 212.20 169.30 38.40 69.70 54.29 13.96 27.40 24.47 14.36 26.90 24.14 14.63
CBR 1 1.0-1.5 - 25 176.60 143.10 36.30 78.90 59.90 13.91 27.70 24.60 14.55 28.10 25.00 14.98
2 1.0-1.5 - 22 188.40 153.50 38.50 79.30 60.00 13.50 27.90 24.80 14.61 27.50 24.45 14.47
3 1.0-1.5 - 25 231.20 192.10 43.70 73.80 59.00 14.07 28.20 26.00 15.68 27.90 25.46 14.09
4 1.0-1.5 - 25 217 197.20 37.10 77.30 62.20 16.65 28.60 26.00 14.43 29.50 26.95 15.69
Jefe de Laboratorio:
Jesus Alfonso Meneses
Hoja: Calculo
Página 3 de 6 Archivo:Clasif-USCS COLISEO MAYOR
CESCO S.A
RESULTADO DE LOS ENSAYOS DE LABORATORIO.
DEO TRA didad(m) /pie) 2 1½ 1 3/4 1/2 3/8 4 10 40 100 200 % % % % % % USCS
1 1 0.5-1.0 4 100 92.7 90 83.1 77.3 64.1 50.5 29.65 41.29 31.41 9.88 -0.18 23.00 ML
2 1.5-2.0 4 100 90.9 90.9 82.8 75.6 58.1 46.7 33.69 39.59 30.28 9.31 0.37 22.21 SM-SC
3 3.0-3.5 3 100 99.2 98.2 92.4 74.4 36.33 46.79 34.77 12.02 0.13 25.59 ML
4 4.5-5.0 6 100 96.3 96.3 94 88.7 73.2 40.89 47.52 35.24 12.28 0.46 25.93 ML
5 6.0-6.5 3 100 96.8 94.5 88.9 65.1 36.87 46.83 34.71 12.12 0.18 25.61 ML
6 7,5-8,0 11 100 97 91.4 82.8 65.2 31.40 38.20 26.03 12.17 0.44 21.55 ML-CL
7 9,0-9,5 45 100 98.3 94.8 87 66.8 30.61 39.52 29.66 9.86 0.10 22.17 ML
8 10,5-11,0 17 100 99.1 96.3 76.7 55.4 23.06 38.64 29.53 9.11 -0.71 21.76 ML
2 1 0.5-1.0 3 100 94.7 92.6 82.8 75.7 56.9 41.5 31.84 38.82 30.68 8.14 0.14 21.84 SM
2 1.5-2.0 3 100 79.1 68.4 68.4 65.5 61.9 51.9 40.4 27.20 37.71 30.43 7.28 -0.44 21.33 GM
3 3.0-3.5 4 100 99.2 95.9 81.8 37.81 47.35 35.22 12.13 0.21 25.86 ML
4 4.5-5.0 5 100 98.7 97 90.6 72.9 39.87 52.80 37.80 15.01 0.14 28.42 MH
5 6.0-6.5 4 100 96 92.4 87 68.5 38.52 47.55 34.59 12.96 0.30 25.95 ML
6 7,5-8,0 12 100 85.4 65 63.5 59.8 58.1 53.3 38.8 21.10 36.24 29.49 6.75 -1.24 20.63 GM
7 9,0-9,5 20 100 91.7 87.7 81 65.8 30.82 38.93 28.69 10.23 0.21 21.90 ML
8 10,5-11,0 13 100 98 93.8 80.8 58.8 36.43 57.12 28.99 28.12 0.26 30.44 CH-MH
9 12,0-12,5 +50 100 95.6 91.6 85.6 71 27.72 38.82 29.55 9.26 -0.20 21.84 ML
3 1 0.5-1.0 3 100 87.4 84.4 73.5 67 57.9 44.9 30.99 37.60 28.62 8.98 0.26 21.27 SM-SC
2 1.5-2.0 4 100 98.8 97.9 94.9 79.3 34.10 48.20 35.41 12.79 -0.10 26.25 ML
3 3.0-3.5 4 100 9.3 98.3 93.6 79.1 42.03 48.67 36.27 12.40 0.46 26.48 ML
4 4.5-5.0 6 100 98.9 97.6 92.1 80.7 43.60 47.69 35.79 11.89 0.66 26.01 ML
5 6.0-6.5 7 100 97.3 95.4 89.9 76.5 39.44 49.27 34.18 15.09 0.35 26.76 ML
6 7,5-8,0 8 100 91.8 87.1 84.1 80.9 78.2 71.9 55 28.08 39.83 29.13 10.71 -0.10 22.32 ML
7 9,0-9,5 23 100 94.2 91.1 82.6 65.2 29.97 38.41 28.44 9.97 0.15 21.65 ML
8 10,5-11,0 13 100 98.3 96.2 87.4 72.7 38.49 39.83 30.63 9.20 0.85 22.32 ML
9 12,0-12,5 +50 100 99.4 96.7 88.7 70.6 36.88 40.12 31.98 8.14 0.60 22.46 ML
10 13,5-14,0 +50 100 97 90.6 75.2 51.7 26.51 37.80 30.43 7.37 -0.53 21.37 ML
Hoja: Calculo
Página 4 de 6 Archivo:Clasif-USCS COLISEO MAYOR
CESCO S.A
RESULTADO DE LOS ENSAYOS DE LABORATORIO.
DEO TRA didad(m) /pie) 2 1½ 1 3/4 1/2 3/8 4 10 40 100 200 % % % % % % USCS
4 1 0.5-1.0 4 100 88.4 87.3 75.4 68.2 59.4 41.7 30.54 38.83 30.73 8.10 -0.02 21.85 SM
2 1.5-2.0 6 100 98.7 94.7 78 36.72 49.58 36.37 13.21 0.03 26.90 ML
3 3.0-3.5 5 100 93.1 72.1 64.9 64.9 61.7 60.3 55 42.6 26.60 40.52 33.80 6.71 -1.07 22.64 GM
4 4.5-5.0 6 100 92.9 85.9 83.6 80.4 78 72.1 57.9 37.30 41.61 28.78 12.83 0.66 23.16 ML-CL
5 6.0-6.5 7 100 98.6 97.6 94 83.7 66.8 38.53 43.93 36.57 7.36 0.27 24.25 ML
6 7,5-8,0 10 100 84.6 84.6 79.9 77.4 70.8 67.3 61.1 44.3 23.64 37.63 29.30 8.33 -0.68 21.29 GM-GC
7 9,0-9,5 23 100 96.5 93.4 88.2 79.2 56.4 29.28 39.63 31.09 8.54 -0.21 22.23 ML
8 10,5-11,0 13 100 99.3 96 86 66.4 34.75 38.74 30.86 7.88 0.49 21.81 ML
9 12,0-12,5 +50 100 98.2 95.9 87.4 67.9 32.57 38.83 28.53 10.30 0.39 21.85 ML
10 13,5-14,0 +50 100 98.2 95.9 89 72.9 33.59 39.32 29.58 9.74 0.41 22.08 ML
5 1 0.5-1.0 3 100 96.8 94.1 88.5 71.1 31.98 40.61 29.33 11.28 0.24 22.68 ML
SH 2 1.5-2.0 5 100 97.6 92.7 87.4 67.7 52.7 32.83 46.03 31.80 14.23 0.07 25.23 ML
3 3.0-3.5 3 100 95.6 95.6 92.4 90.1 84.9 68.6 39.56 48.53 35.76 12.78 0.30 26.41 ML
4 4.5-5.0 7 100 98.2 92.9 76.1 41.38 49.35 18.97 30.37 0.74 26.79 CL
5 6.0-6.5 4 100 98.2 96.8 94.4 88.6 74.1 40.57 51.83 37.81 14.02 0.20 27.96 MH
6 7,5-8,0 2 100 98.6 92.9 83.4 52.77 42.60 32.72 9.88 2.03 23.62 ML
7 9,0-9,5 3 100 99.1 98 90.6 77.6 48.27 41.91 32.18 9.72 1.65 23.30 ML
8 10,5-11,0 14 100 96.5 87.7 74.6 42.49 40.60 32.03 8.56 1.22 22.68 ML
9 12,0-12,5 45 100 89.3 89.3 82 76.4 64.4 48.4 22.95 38.00 32.11 5.89 -1.55 21.46 SM
10 13,5-14,0 +50 100 80.3 76 73.5 69 66 58.6 46.3 20.57 36.74 30.50 6.23 -1.59 20.87 GM
6 1 0.5-1.0 2 100 88.2 83.4 81.4 79.6 77.7 70 50.1 24.40 38.03 29.79 8.24 -0.65 21.47 ML
2 1.5-2.0 5 100 99.4 96.3 81.6 36.80 48.83 36.02 12.81 0.06 26.55 ML
3 3.0-3.5 3 100 98.2 96.6 92.5 71.9 44.26 48.62 36.18 12.44 0.65 26.45 ML
4 4.5-5.0 5 100 96.8 95.5 91.7 69.7 39.33 49.35 36.81 12.54 0.20 26.79 ML
5 6.0-6.5 5 100 92 92 85.3 80.5 71.9 60.9 40.23 39.83 28.81 11.02 1.04 22.32 ML
6 7,5-8,0 3 100 98.4 89.8 77.5 44.68 40.72 32.19 8.53 1.46 22.74 ML
7 9,0-9,5 3 100 98.8 97.6 91 76.9 43.60 39.51 29.92 9.60 1.43 22.17 ML
8 10,5-11,0 14 100 90.7 88.4 82.5 77.8 67.8 52.1 36.99 37.81 32.23 5.59 0.85 21.37 ML
9 12,0-12,5 48 100 97.9 93.8 84.3 68.8 39.72 38.61 29.34 9.28 1.12 21.75 ML
10 13,5-14,0 +50 100 97.1 94.2 90 78.7 59.1 29.41 37.40 29.49 7.91 -0.01 21.18 ML
Hoja: Calculo
Página 5 de 6 Archivo:Clasif-USCS COLISEO MAYOR
CESCO S.A
RESULTADO DE LOS ENSAYOS DE LABORATORIO.
DEO TRA didad(m) /pie) 2 1½ 1 3/4 1/2 3/8 4 10 40 100 200 % % % % % % USCS
7 1 0.5-1.0 3 100 88.7 84.1 76.3 70.1 55.5 42.9 31.74 38.93 30.64 8.29 0.13 21.90 SM
2 1.5-2.0 3 100 98 91.7 76.5 40.05 53.01 38.14 14.87 0.13 28.52 MH
3 3.0-3.5 3 100 97.4 91.9 79.1 44.13 47.15 35.69 11.46 0.74 25.76 ML
4 4.5-5.0 2 100 97.2 97.2 95.6 90.8 80.3 48.90 48.62 36.93 11.69 1.02 26.45 ML
5 6.0-6.5 2 100 99.6 97.1 67.1 35.81 49.18 36.59 12.59 -0.06 26.72 ML
6 7,5-8,0 6 100 93.8 86.6 77.9 65 36.55 39.63 14.57 25.06 0.88 22.23 CL
7 9,0-9,5 4 100 83 81.3 76.2 72.4 67.7 48.9 27.37 37.53 28.92 8.61 -0.18 21.24 SM-SC
8 10,5-11,0 11 100 100 98 69.5 55.77 38.60 29.49 9.12 2.88 21.74 ML
9 12,0-12,5 27 100 100 96.9 59.4 45.91 37.24 29.67 7.57 2.15 21.10 ML
10 13,5-14,0 +50 100 97.7 95.6 91.8 88.5 80.6 66.1 30.31 37.80 30.68 7.12 -0.05 21.37 ML
8 1 0.5-1.0 4 100 99.2 96.3 89.2 70.5 35.25 47.36 35.58 11.78 -0.03 25.86 ML
2 1.5-2.0 5 100 99.1 94.8 80.3 35.86 49.31 36.88 12.44 -0.08 26.78 ML
3 3.0-3.5 5 100 98.3 94.6 78.3 42.32 49.28 37.24 12.04 0.42 26.76 ML
4 4.5-5.0 8 100 98.8 93.4 72.5 42.28 48.80 36.56 12.24 0.47 26.54 ML
5 6.0-6.5 8 100 95.4 95.4 91.2 86.3 73.7 56.8 37.56 38.73 28.62 10.10 0.88 21.80 ML
6 7,5-8,0 11 100 96 93.5 87.4 57.5 34.20 37.61 29.22 8.39 0.59 21.28 ML
7 9,0-9,5 7 100 97.7 97.7 94.4 89.3 82.6 57.9 31.68 38.11 28.29 9.82 0.35 21.51 ML
8 10,5-11,0 7 100 83.4 79.7 78.3 74.6 71.4 61.7 44 26.04 36.90 29.28 7.62 -0.43 20.94 SM-SC
9 12,0-12,5 38 100 98.1 91.7 81.2 74.5 56.5 30.05 37.92 29.72 8.20 0.04 21.42 ML
10 13,5-14,0 +50 100 95.9 92 81.8 64.2 32.77 38.40 29.00 9.40 0.40 21.65 ML
CBR 1 1.0-1.5 - 100 96.8 92.8 90.5 87 73.2 52 31.37 41.31 30.89 10.42 0.05 23.02 ML
2 1.0-1.5 - 100 96.9 96.9 88.6 83.9 70.7 50.4 30.35 40.88 30.49 10.39 -0.01 22.81 ML
3 1.0-1.5 - 100 96.1 93.9 90.1 87.1 77.7 55.5 26.35 32.94 21.39 11.55 0.43 19.08 CL-ML
4 1.0-1.5 - 100 93.9 90 80.3 57.7 12.37 33.15 22.56 10.59 -0.96 19.18 CL-ML
Jefe de laboratorio:
Jesús Alfonso Meneses
Hoja: Calculo
Página 6 de 6 Archivo:Clasif-USCS COLISEO MAYOR
CESCO S.A. COMPAÑIA DE ESTUDIOS DE SUELOS Y CONSULTA
0.005
0.025 3.0 1.8 13.0 7.7
0.05 8.0 4.7 25.0 14.8
0.075 13.0 7.7 37.0 21.8
0.1 18.0 10.6 46.0 27.1
0.15 26.0 15.3 59.0 34.8
0.2 32.0 18.9 68.0 40.1
0.3 40.0 23.6 78.0 46.0
0.4 46.0 27.1 85.0 50.2
0.500 51 30.1 90 53.1
CBR Corregido a
1.1 2.7
0.1" (%)
CBR Corregido a
1.3 2.7
0.2" (%)
Despues
Contenido Húmedo (%) 30.3
Hinchamiento (%) -
CBR 1 (DESPUES)
Presion (p.s.i)
50.0
0.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Penetracion (pulg)
0.005
0.025 4.0 2.4 19.0 11.2
0.05 14.0 8.3 38.0 22.4
0.075 24.0 14.2 52.0 30.7
0.1 34.0 20.1 63.0 37.2
0.15 52.0 30.7 80.0 47.2
0.2 64.0 37.8 93.0 54.9
0.3 82.0 48.4 112.0 66.1
0.4 95.0 56.1 128.0 75.5
0.500 104 61.4 141 83.2
CBR Corregido a
2 3.7
0.1" (%)
CBR Corregido a
2.5 3.7
0.2" (%)
Despues
Contenido Húmedo (%) 36.2
Hinchamiento (%) -
CBR 2 (DESPUES)
Presion (p.s.i)
50.0
0.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Penetracion (pulg)
0.005
0.025 8.0 4.7 14.0 8.3
0.05 22.0 13.0 28.0 16.5
0.075 35.0 20.7 42.0 24.8
0.1 45.0 26.6 55.0 32.5
0.15 58.0 34.2 72.0 42.5
0.2 68.0 40.1 83.0 49.0
0.3 83.0 49.0 98.0 57.8
0.4 95.0 56.1 110.0 64.9
0.500 103 60.8 118 69.6
CBR Corregido a
2.7 3.2
0.1" (%)
CBR Corregido a
2.7 3.3
0.2" (%)
Despues
Contenido Húmedo (%) 27.4
Hinchamiento (%) -
CBR 3 (DESPUES)
Presion (p.s.i)
50.0
0.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Penetracion (pulg)
0.005
0.025 12.0 7.1 21.0 12.4
0.05 27.0 15.9 41.0 24.2
0.075 40.0 23.6 57.0 33.6
0.1 52.0 30.7 69.0 40.7
0.15 70.0 41.3 84.0 49.6
0.2 82.0 48.4 93.0 54.9
0.3 98.0 57.8 104.0 61.4
0.4 110.0 64.9 112.0 66.1
0.500 118 69.6 118 69.6
CBR Corregido a
3.1 4.1
0.1" (%)
CBR Corregido a
3.2 3.7
0.2" (%)
Despues
Contenido Húmedo (%) 24.2
Hinchamiento (%) -
CBR 4 (DESPUES)
Presion (p.s.i)
50.0
0.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Penetracion (pulg)
0.005
0.025 8.0 4.7 12.0 7.1
0.05 17.0 10.0 23.0 13.6
0.075 26.0 15.3 32.0 18.9
0.1 33.0 19.5 39.0 23.0
0.15 44.0 26.0 49.0 28.9
0.2 51.0 30.1 56.0 33.0
0.3 62.0 36.6 66.0 38.9
0.4 70.0 41.3 75.0 44.3
0.500 77 45.4 82 48.4
CBR Corregido a
1.9 2.3
0.1" (%)
CBR Corregido a
2 2.2
0.2" (%)
Despues
Contenido Húmedo (%) 40.6
Hinchamiento (%) -
CBR 5 (DESPUES)
Presion (p.s.i)
50.0
0.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Penetracion (pulg)
0.005
0.025 7.0 4.1 17.0 10.0
0.05 16.0 9.4 27.0 15.9
0.075 24.0 14.2 36.0 21.2
0.1 31.0 18.3 44.0 26.0
0.15 43.0 25.4 55.0 32.5
0.2 53.0 31.3 62.0 36.6
0.3 70.0 41.3 72.0 42.5
0.4 82.0 48.4 80.0 47.2
0.500 90 53.1 88 51.9
CBR Corregido a
1.8 2.6
0.1" (%)
CBR Corregido a
2.1 2.4
0.2" (%)
Despues
Contenido Húmedo (%) 39.5
Hinchamiento (%) -
CBR 6 (DESPUES)
Presion (p.s.i)
50.0
0.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Penetracion (pulg)
0.005
0.025 10.0 5.9 10.0 5.9
0.05 22.0 13.0 23.0 13.6
0.075 33.0 19.5 34.0 20.1
0.1 43.0 25.4 43.0 25.4
0.15 59.0 34.8 58.0 34.2
0.2 70.0 41.3 68.0 40.1
0.3 83.0 49.0 83.0 49.0
0.4 90.0 53.1 93.0 54.9
0.500 97 57.2 101 59.6
CBR Corregido a
2.5 2.5
0.1" (%)
CBR Corregido a
2.8 2.7
0.2" (%)
Despues
Contenido Húmedo (%) 31.1
Hinchamiento (%) -
CBR 7 (DESPUES)
Presion (p.s.i)
50.0
0.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Penetracion (pulg)
4
INDICE DE EXPANSIVIDAD kg/cm²
SECO O HUMEDO
1 L PLASTICO
0
0 1 2 3 4 5 6 7 8 9 10
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO PERCOLACION : PER-1
INSPECTOR : CESAR CAJIAO FECHA : ENERO DE 2015 DIMENSION : 0,20 x 0,20
9:00 AM
9:15 AM
1.00 MT
15
9:30 AM 30 0.39 76.20
9:45 AM 45 0.79 57.15
10:00 AM 60 1.18 50.80
10:15 AM
1.00 MT
10:30 AM 15
10:45 AM 30 0.39 76.20
11:00 AM 45 0.79 57.15
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MAYOR - QUIBDO PERCOLACION : PER-2
INSPECTOR : CESAR CAJIAO FECHA : ENERO DE 2015 DIMENSION : 0,20 x 0,20
9:30 AM - -
9:45 AM - -
1.00 MT
15
10:00 AM 30 0.39 76.20
10::15 AM 45 0.79 57.15
10:30 AM 60
10:45 AM
1.00 MT
ANEXO 3-A
REGISTRO FOTOGRÁFICO.
Apiques manuales para ensayos de percolación
Apique manual para extraer muetra de suelo inalterado para ensayo de CBR
Apique manual para extraer muetra de suelo inalterado para ensayo de CBR
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
ANEXO 1-B
REGISTROS EXPLORATORIOS
DE PERFORACIÓN.
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MENOR QUIBDO SONDEO: P-9
LOCALIZACION : Ver. Figura 2 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MENOR QUIBDO SONDEO: P-9
LOCALIZACION : Ver. Figura 2 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MENOR QUIBDO SONDEO: P-10
LOCALIZACION : Ver. Figura 2 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 3.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MENOR QUIBDO SONDEO: P-10
LOCALIZACION : Ver. Figura 2 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 3.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MENOR QUIBDO SONDEO: P-11
LOCALIZACION : Ver. Figura 2 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 2.80 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MENOR QUIBDO SONDEO: P-11
LOCALIZACION : Ver. Figura 2 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 2.80 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MENOR QUIBDO SONDEO: P-12
LOCALIZACION : Ver. Figura 2 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 2.50 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MENOR QUIBDO SONDEO: P-12
LOCALIZACION : Ver. Figura 2 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 2.50 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MENOR QUIBDO SONDEO: P-13
LOCALIZACION : Ver. Figura 2 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 1 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 2.50 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEO MENOR QUIBDO SONDEO: P-13
LOCALIZACION : Ver. Figura 2 INSPECTOR : CESAR CAJIAO FECHA :ENERO DE 2015
PAG. 2 de 2
SACAMUESTRAS TIPO :CUCHARA - Peso martillo : 140 lbs. Caida : 30"
PROFUNDIDAD DE LA CAPA FREATICA : 2.50 mt
ANEXO 2-B
RESULTADOS DE LOS
ENSAYOS DE LABORATORIO.
CESCO S.A
DATOS ENSAYOS DE LABORATORIO
OBRA: COLISEO MENOR QUIBDO CLIENTE : ZOCALO ARQUITECTURA SAS N. OBRA 15-001 FECHA ene-15
DEO TRA didad(m) /pie) casagrande) P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R.
9 1 0.5-1.0 3 26 246.00 194.70 38.00 69.70 53.92 14.08 26.80 23.70 14.16 26.60 23.55 14.16
2 1.5-2.0 5 24 99.20 77.30 16.65 70.80 52.52 14.84 26.90 23.51 14.16 26.60 23.63 15.44
3 3.0-3.5 4 25 109.30 81.00 14.60 69.40 51.39 14.88 27.10 23.63 14.18 26.30 22.99 14.00
4 4.5-5.0 8 25 228 170.40 38.70 70.60 52.74 14.91 26.80 23.47 14.19 26.60 23.36 14.32
5 6.0-6.5 10 25 244.50 201.40 37.40 67.40 52.55 14.08 27.80 24.70 14.53 26.50 23.73 14.61
6 7,5-8,0 17 27 249.70 219.10 40.10 68.10 53.43 14.65 26.40 23.54 14.38 26.80 23.89 14.62
7 9,0-9,5 33 24 272.40 239.10 37.70 69.70 54.34 14.36 27.10 24.03 14.06 26.80 23.83 14.13
8 10,5-11,0 +50 25 284.70 246.10 36.60 72.80 56.88 14.56 26.80 23.91 14.16 26.60 23.76 14.16
9 12,0-12,5 +50 27 85.60 64.60 15.34 73.80 48.90 14.91 28.00 23.90 14.12 27.80 24.03 15.04
10 1 0.5-1.0 5 24 97.00 74.40 17.75 69.40 50.05 14.08 26.80 23.35 14.38 26.70 23.57 15.41
2 1.5-2.0 8 25 89.70 67.30 15.52 71.40 51.83 14.84 26.80 23.30 14.16 26.90 23.54 14.64
3 3.0-3.5 7 26 106.80 81.90 16.90 67.70 50.65 15.63 26.40 23.26 14.63 26.60 23.30 14.16
4 4.5-5.0 6 25 249.9 196.50 44.00 70.80 55.04 14.82 26.80 23.80 14.32 26.40 23.47 14.22
5 6.0-6.5 6 23 269.70 217.70 44.30 67.40 52.25 14.00 26.90 23.87 14.36 26.40 23.63 14.94
6 7,5-8,0 20 25 265.30 220.30 42.30 68.40 53.73 14.92 27.60 24.58 14.38 27.80 24.93 15.22
7 9,0-9,5 35 26 317.70 279.10 36.60 69.30 54.42 14.82 27.40 24.56 14.65 27.60 24.99 15.81
8 10,5-11,0 +50 25 284.00 252.80 25.60 68.80 54.10 14.84 26.90 24.15 14.65 26.60 23.84 14.29
9 12,0-12,5 +50 25 82.90 62.50 14.07 69.80 46.30 13.96 27.70 23.66 14.12 27.40 23.47 14.19
11 1 0.5-1.0 4 24 103.10 80.50 14.61 69.40 50.12 14.81 27.60 24.09 14.84 26.40 23.10 14.38
2 1.5-2.0 4 26 100.80 78.50 14.10 64.90 47.29 14.38 26.40 23.05 14.31 26.80 24.04 16.83
3 3.0-3.5 4 25 275.50 219.20 38.80 67.30 51.22 14.52 26.40 23.10 13.67 26.80 23.52 14.16
4 4.5-5.0 11 25 290.8 239.70 38.30 70.40 53.39 14.29 26.90 23.58 14.36 27.20 24.06 15.33
5 6.0-6.5 15 25 261.40 213.50 41.30 69.40 52.55 14.61 26.90 23.86 14.74 26.40 23.38 14.30
6 7,5-8,0 27 27 234.60 203.40 39.00 71.40 55.25 14.08 26.80 24.08 14.91 26.60 23.78 14.24
7 9,0-9,5 22 24 340.40 298.70 43.80 72.00 56.12 14.11 26.80 24.15 15.38 26.70 23.82 14.29
8 10,5-11,0 +50 25 280.90 236.80 38.20 61.80 48.63 14.16 27.10 24.10 14.38 27.40 24.39 14.65
9 12,0-12,5 +50 25 86.00 59.70 13.35 70.40 46.84 13.86 26.90 23.25 14.51 26.60 23.09 14.74
Hoja: Calculo
Página 1 de 4 Archivo:Clasif-USCS.. COLISEO MENOR
CESCO S.A
DATOS ENSAYOS DE LABORATORIO
OBRA: COLISEO MENOR QUIBDO CLIENTE : ZOCALO ARQUITECTURA SAS N. OBRA 15-001 FECHA ene-15
DEO TRA didad(m) /pie) casagrande) P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R.
12 1 0.5-1.0 5 23 86.50 67.10 15.30 69.40 49.90 14.31 26.70 23.48 14.92 26.40 23.46 15.63
2 1.5-2.0 5 26 93.20 71.10 16.08 67.80 49.10 14.21 26.90 23.40 14.23 26.60 23.16 14.19
3 3.0-3.5 10 25 108.80 79.80 14.83 68.70 51.56 15.04 27.40 24.07 14.63 26.90 23.70 14.66
4 4.5-5.0 8 24 115.1 90.10 17.65 69.90 51.82 14.08 26.80 23.45 14.06 26.60 23.34 14.19
5 6.0-6.5 8 23 250.20 202.60 38.00 69.60 54.20 14.86 26.70 23.50 14.62 27.10 24.00 15.38
6 7,5-8,0 18 25 227.40 187.00 43.70 70.40 55.13 14.64 27.80 24.36 14.63 27.60 24.35 15.18
7 9,0-9,5 21 28 306.80 264.40 38.30 67.40 53.00 14.53 26.80 23.50 14.08 26.60 23.53 14.81
8 10,5-11,0 40 25 288.20 252.80 37.20 70.40 54.96 14.63 26.60 23.56 15.16 26.40 23.30 14.74
9 12,0-12,5 +50 25 267.00 228.40 36.30 72.20 56.56 15.09 27.60 24.36 14.91 27.40 23.98 14.08
13 1 0.5-1.0 3 25 98.70 75.00 14.18 69.40 50.06 14.84 26.60 23.44 14.86 26.80 23.45 14.31
2 1.5-2.0 7 27 98.90 75.70 14.07 70.40 52.28 14.36 26.60 23.30 14.16 26.80 23.67 14.96
3 3.0-3.5 11 24 106.60 81.90 15.93 67.70 50.40 14.19 27.20 23.85 14.74 27.40 24.03 14.91
4 4.5-5.0 20 25 269.2 215.60 38.00 68.40 52.13 15.31 26.50 23.40 14.42 26.30 23.13 13.96
5 6.0-6.5 14 26 237.40 205.70 36.70 70.40 54.97 14.16 26.40 23.55 13.67 26.60 23.92 14.63
6 7,5-8,0 22 25 301.70 259.90 38.30 69.80 54.84 14.74 27.40 24.43 14.38 27.20 24.22 14.16
7 9,0-9,5 +50 26 237.80 206.90 38.10 69.10 53.92 14.40 26.60 23.80 14.05 26.80 24.00 14.24
8 10,5-11,0 +50 24 261.60 230.40 41.00 72.20 56.22 13.96 27.30 24.70 15.44 26.80 24.00 14.08
SH 1 1.0-1.5 - 22 200.60 153.90 37.70 75.90 53.90 15.47 28.40 24.60 15.02 28.00 24.25 14.83
2 1.0-1.5 - 25 182.70 141.80 38.40 72.60 50.70 14.26 27.70 23.90 13.78 28.60 25.11 15.85
CBR 5 1.0-1.5 - 22 212.20 160.60 38.80 67.70 49.10 15.22 27.20 24.00 14.68 27.00 23.76 14.38
6 1.0-1.5 - 23 194.20 147.30 36.90 70.40 50.70 15.05 27.60 24.20 14.26 28.10 25.00 15.91
7 1.0-1.5 - 25 210.30 167.30 38.10 75.50 59.90 14.52 28.20 25.20 15.28 27.80 24.76 14.74
Jefe de Laboratorio:
Jesus Alfonso Meneses
Hoja: Calculo
Página 2 de 4 Archivo:Clasif-USCS.. COLISEO MENOR
CESCO S.A
RESULTADO DE LOS ENSAYOS DE LABORATORIO.
DEO TRA didad(m) /pie) 2 1½ 1 3/4 1/2 3/8 4 10 40 100 200 % % % % % % USCS
9 1 0.5-1.0 3 100 95.1 93.6 88.8 83.1 71.7 54.1 32.74 39.81 32.49 7.32 0.03 22.31 ML
2 1.5-2.0 5 100 97.4 94.4 89.4 77.7 36.11 48.27 36.26 12.01 -0.01 26.29 ML
3 3.0-3.5 4 100 98.5 96.1 89.6 73.6 42.62 49.33 36.77 12.56 0.47 26.78 ML
4 4.5-5.0 8 100 93.3 86.8 80.7 63.6 43.74 47.21 35.86 11.35 0.69 25.79 ML
5 6.0-6.5 10 100 79.7 77.5 73.7 70.1 62.9 49.1 26.28 38.60 30.43 8.17 -0.51 21.74 GM
6 7,5-8,0 17 100 84.4 84.4 78.5 77.4 74.7 72 66.7 46 17.09 38.17 31.31 6.86 -2.07 21.54 SM
7 9,0-9,5 33 100 91.5 85.7 85.7 80.8 77 67.6 46 16.53 38.23 30.71 7.52 -1.88 21.57 SM
8 10,5-11,0 +50 100 93.7 90.3 90.3 85.3 78.6 63.8 38.7 18.42 37.62 29.61 8.01 -1.40 21.28 SM-SC
9 12,0-12,5 +50 100 97.8 92.7 81.3 42.63 73.92 41.93 31.99 0.02 38.34 MH
10 1 0.5-1.0 5 100 100 97.7 76.7 39.89 53.53 38.41 15.12 0.10 28.76 MH
2 1.5-2.0 8 100 99.2 96.9 84.7 43.26 52.91 38.02 14.88 0.35 28.47 MH
3 3.0-3.5 7 100 97.5 95 93.8 89.2 74.3 38.31 48.93 36.24 12.69 0.16 26.60 ML
4 4.5-5.0 6 100 97.2 95.2 90.5 87.8 75.4 58.2 35.02 39.18 31.66 7.52 0.45 22.02 ML
5 6.0-6.5 6 100 95.8 89.8 85.1 79.9 69.6 54.5 29.99 39.21 31.87 7.34 -0.26 22.03 ML
6 7,5-8,0 20 100 98.1 98.1 94.7 91.7 83 53.3 25.28 37.80 29.59 8.21 -0.52 21.37 ML
7 9,0-9,5 35 100 72.4 68.2 61.5 61.5 57.4 55.6 51.1 33.9 15.92 37.76 28.54 9.22 -1.37 21.35 GM-GC
8 10,5-11,0 +50 100 93.1 84.1 80.7 72.7 66.8 56.4 38.3 13.73 37.44 28.92 8.52 -1.78 21.20 SM-SC
9 12,0-12,5 +50 100 100 100 97.9 42.12 72.67 42.35 30.32 -0.01 37.75 MH
11 1 0.5-1.0 4 100 97.2 90.1 75.1 61.3 34.30 54.33 37.89 16.43 -0.22 29.13 MH
2 1.5-2.0 4 100 97.4 95 87.1 71.4 34.63 53.78 38.30 15.47 -0.24 28.88 MH
3 3.0-3.5 4 100 93.5 88.5 86.9 81.1 78 72.9 56.5 31.21 43.81 35.02 8.80 -0.43 24.19 ML
4 4.5-5.0 11 100 85.4 80.2 75.1 75.1 73.8 72.3 66.7 48.6 25.37 43.50 35.99 7.52 -1.41 24.05 GM
5 6.0-6.5 15 100 97.7 93.9 90.2 83.8 64.1 27.82 44.41 33.30 11.12 -0.49 24.47 ML
6 7,5-8,0 27 100 94 86.1 86.1 83.4 81.2 76.6 51.5 18.98 39.58 29.61 9.97 -1.07 22.20 ML
7 9,0-9,5 22 100 92.9 90.9 80.2 72.4 58.9 42.8 16.36 37.61 30.22 7.39 -1.87 21.28 SM
8 10,5-11,0 +50 100 93.1 89.6 89.6 83.7 76 61.9 45.2 22.21 38.21 30.88 7.32 -1.19 21.56 SM
9 12,0-12,5 +50 100 100 97 92.9 56.74 71.44 41.90 29.54 0.50 37.18 MH
Hoja: Calculo
Página 3 de 4 Archivo:Clasif-USCS.. COLISEO MENOR
CESCO S.A
RESULTADO DE LOS ENSAYOS DE LABORATORIO.
DEO TRA didad(m) /pie) 2 1½ 1 3/4 1/2 3/8 4 10 40 100 200 % % % % % % USCS
12 1 0.5-1.0 5 100 98.5 94.4 78 37.45 54.24 37.58 16.66 -0.01 29.09 MH
2 1.5-2.0 5 100 98.6 96.8 91.5 79.3 40.17 53.87 38.26 15.61 0.12 28.92 MH
3 3.0-3.5 10 100 98.7 96.9 94.3 81.8 44.64 46.93 35.34 11.60 0.80 25.66 ML
4 4.5-5.0 8 100 96.8 96.8 91 86.7 80.9 64.8 34.51 47.67 35.65 12.01 -0.10 26.00 ML
5 6.0-6.5 8 100 91.8 91.8 85.8 82 71.2 55.3 28.92 38.75 36.00 2.75 -2.57 21.81 ML
6 7,5-8,0 18 100 98.8 91.2 87.5 82.3 58.6 28.19 37.71 35.40 2.31 -3.11 21.33 ML
7 9,0-9,5 21 100 95.5 95.5 93.4 85.2 79.8 69.6 51.2 18.75 37.96 35.12 2.84 -5.77 21.44 ML
8 10,5-11,0 40 100 94.3 92 92 86.5 82.4 76 54.9 16.42 38.28 36.20 2.08 -9.50 21.59 ML
9 12,0-12,5 +50 100 94.2 92.6 88.3 85.8 80.2 62 20.09 37.71 34.42 3.30 -4.34 21.33 ML
13 1 0.5-1.0 3 100 99.2 94.9 81.2 38.97 54.91 36.74 18.17 0.12 29.41 MH
2 1.5-2.0 7 100 99.4 98.1 93.2 77.1 37.64 48.21 36.02 12.19 0.13 26.26 ML
3 3.0-3.5 11 100 99.1 96.8 90.6 76.7 37.44 47.54 36.86 10.68 0.05 25.94 ML
4 4.5-5.0 20 100 96 91.6 78.6 55.7 30.18 44.19 34.55 9.64 -0.45 24.37 ML
5 6.0-6.5 14 100 82.4 80.3 80.3 75.2 71.2 65.6 41.2 18.76 38.00 28.85 9.15 -1.10 21.46 SM-SC
6 7,5-8,0 22 100 91.9 91.9 90.1 84.3 79.1 70.3 49.5 18.86 37.31 29.59 7.72 -1.39 21.13 SM-SC
7 9,0-9,5 +50 100 96.9 91.1 84 70.1 51.3 18.31 38.60 28.70 9.90 -1.05 21.74 ML
8 10,5-11,0 +50 100 91.9 91.9 86.7 78.5 70.7 61.5 16.47 37.62 28.15 9.47 -1.23 21.28 ML
SH 1 1.0-1.5 - 100 99.1 93.8 81.1 40.19 56.39 39.74 16.65 0.03 30.10 MH
2 1.0-1.5 - 100 98.6 97 90.9 77.7 39.56 60.10 37.62 22.48 0.09 31.85 MH
CBR 5 1.0-1.5 - 100 99 97.9 93.1 77.3 42.36 54.08 34.44 19.64 0.40 29.02 MH
6 1.0-1.5 - 100 98.2 96.8 92.7 77.3 42.48 54.71 34.15 20.55 0.41 29.31 MH
7 1.0-1.5 - 100 98.4 94.7 83.9 62.6 33.28 34.38 30.29 4.09 0.73 19.76 ML
Jefe de laboratorio:
Jesús Alfonso Meneses
Hoja: Calculo
Página 4 de 4 Archivo:Clasif-USCS.. COLISEO MENOR
CESCO S.A. PRESIÓN DE EXPANSIÓN
4
INDICE DE EXPANSIVIDAD kg/cm²
SECO O HUMEDO
1 L PLASTICO
0
0 1 2 3 4 5 6 7 8 9 10
4
INDICE DE EXPANSIVIDAD kg/cm²
SECO O HUMEDO
1 L PLASTICO
0
0 1 2 3 4 5 6 7 8 9 10
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEOS MENOR QUIBDO PERCOLACION : PER-1
INSPECTOR : CESAR CAJIAO FECHA : ENERO DE 2015 DIMENSION : 0,20 x 0,20
10:00 AM
10:15 AM
1.00 MT
15
10:30 AM 30 0.39 76.20
10:45 AM 45 0.79 57.15
11:00 AM 60 1.18 50.80
11:15 AM
1.00 MT
11:30 AM 15
11:45 AM 30 0.39 76.20
12:00 AM 45 0.79 57.15
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEOS MENOR QUIBDO PERCOLACION : PER-2
INSPECTOR : CESAR CAJIAO FECHA : ENERO DE 2015 DIMENSION : 0,20 x 0,20
10:30 AM - -
10:45 AM
1.00 MT
15 - -
11:00 AM 30 0.39 76.20
11::15 AM 45 0.79 57.15
11:30 AM 60 1.18 50.80
ANEXO 3-B
REGISTRO FOTOGRÁFICO.
Apique manual para extraer muetra de suelo inalterado para ensayo de CBR
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
ANEXO 1-C
REGISTROS EXPLORATORIOS
DE PERFORACIÓN.
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEOS QUIBDO - ISTMNAS SONDEO: P-1
LOCALIZACION : Ver figura 3 PERFORADOR: Cesar Cajiao FECHA : Enero 2015
_ _ _ _ _
Relleno de grava limo arcilo arenosa
_ _ _ _ Color gris oscuro y café _
Desechos y gravas
_ _ _ _ _
C-1 Arena (F.M.G.) HN>LP
_ _ 6-8-10 _ 18 _ _
B1 80% GM-GC
___________________
___________________
1 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ jjjjjjjjjjjjjjj
_
Grava limo arcillo arenosa jjjjjjjjjjjjjjj
_ _ _ _ Color café claro con algo de areniscasjjjjjjjjjjjjjjj
_
C-2 Arena (F.M.G.) HN>LP jjjjjjjjjjjjjjj
_ _ 7-5-3 _ 8 _ jjjjjjjjjjjjjjj
_
B2 80% jjjjjjjjjjjjjjj
___________________
___________________
2 ___________________
___________________ GM-GC jjjjjjjjjjjjjjj
__
jjjjjjjjjjjjjjj
_ _ _ _ jjjjjjjjjjjjjjj
_
jjjjjjjjjjjjjjj
_ _ _ _ jjjjjjjjjjjjjjj
_
jjjjjjjjjjjjjjj
_ _ _ _ jjjjjjjjjjjjjjj
_
jjjjjjjjjjjjjjj
_ _ _ _ _
Limo arenoso
___________________
___________________
3 ___________________
___________________ Color café oscuro __
Arena (F.M.) HN>LP
_ _ C-3 _ _ _
3-1-1 2 ML
_ _ B3 80% _ _ _
Limo arcillo arenoso
_ _ _ _ Color café con trazas gris _
Arena (F.M.) HN>LP
_ _ _ _ _
___________________
___________________
4 ___________________
25-30-30 ___________________ __
_ _ _ _ Arcilla limosa _
Color gris oscuro
_ _ _ _ Arena (F.M.) HN>LP _
_ _ _ _ _
C-4
_ _ 58-60/4cm _ +50 _ CL-ML _
B4 60%
___________________
___________________
5 ___________________
___________________ __
_ _ _ _ Fechazo 5 mt _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
6 ___________________
___________________ _
SACAMUESTRAS TIPO :CUCHARA PESO MARTILLO : 140 LBS CAIDA 30" PROFUNDIDAD DE LA CAPA FREATICA : 4.00 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEOS QUIBDO - ISTMNAS SONDEO: P-2
LOCALIZACION : Ver figura 3 PERFORADOR: Cesar Cajiao FECHA : Enero 2015
_ _ _ _ _
Relleno de arena limo arenoso
_ _ _ _ Color gris oscuro con vetas cafes _
Arena (F.M.G.) HN>LP
_ _ _ _ _
C-1
_ _ _ _ _
1-1-1 2 SM-SC
B1 80%
___________________
___________________
1 ___________________
___________________ __
_ _ _ _ ML-CL _
C-2
_ _ 8-16-36 _ +50 _ _
B2 80%
___________________
___________________
2 ___________________
___________________ __
Arcilla inorganica
_ _ C-3 _ _ Color gris oscuro _
60-70/7cm +50 Arena (F.M.) HN>LP
_ _ B3 80% _ _ CL _
_ _ _ _ _
Fechazo 2.5 mt
_ _ _ _ _
___________________
___________________
3 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
4 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
5 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
6 ___________________
___________________ _
SACAMUESTRAS TIPO :CUCHARA PESO MARTILLO : 140 LBS CAIDA 30" PROFUNDIDAD DE LA CAPA FREATICA : N.A.
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEOS QUIBDO - ISTMNAS SONDEO: P-3
LOCALIZACION : Ver figura 3 PERFORADOR: Cesar Cajiao FECHA : Enero 2015
_ _ _ _ Arcilla limosa _
C-1 Color gris oscuro
_ _ 5-8-10 _ 18 _ Arena (F.M.) HN>LP _
B1 80%
___________________
___________________
1 ___________________
___________________ CL-ML __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
C-2
_ _ 8-14-18 _ 32 _ Limo arcilloso _
B2 80% Color gris oscuro
___________________
___________________
2 ___________________
___________________ Arena (F.M.) HN>LP __
ML-CL
_ _ _ _ _
_ _ _ _ Arcilla limosa _
Color gris oscuro
_ _ _ _ Arena (F.M.) HN>LP _
C-3 CL-ML
_ _ 48-70/7cm _ +50 _ _
B3 80%
___________________
___________________
3 ___________________
___________________ __
_ _ _ _ Fechazo 3 mt _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
4 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
5 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
6 ___________________
___________________ _
SACAMUESTRAS TIPO :CUCHARA PESO MARTILLO : 140 LBS CAIDA 30" PROFUNDIDAD DE LA CAPA FREATICA : N.A.
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEOS QUIBDO - ISTMNAS SONDEO: P-4
LOCALIZACION : Ver figura 3 PERFORADOR: Cesar Cajiao FECHA : Enero 2015
_ _ _ _ _
C-1 GM-GC
_ _ 9-5-4 _ 9 _ _
B1 80%
___________________
___________________
1 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
C-2
_ _ 3-4-4 _ 8 _ _
B2 80%
___________________
___________________
2 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ Limo arcilloso _
Color gris oscuro
_ _ _ _ Arena (F.M.) HN>LP _
___________________
___________________
3 ___________________
___________________ __
_ _ _ _ SM-SC _
C-4
_ _ 65-70/6cm _ +50 _ _
B4 80%
___________________
___________________
4 ___________________
___________________ __
Fechazo 4 mt
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
5 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
6 ___________________
___________________ _
SACAMUESTRAS TIPO :CUCHARA PESO MARTILLO : 140 LBS CAIDA 30" PROFUNDIDAD DE LA CAPA FREATICA : 1.0 mt
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEOS QUIBDO - ISTMNAS SONDEO: P-5
LOCALIZACION : Ver figura 3 PERFORADOR: Cesar Cajiao FECHA : Enero 2015
_ _ _ _ _
_ _ _ _ jjjjjjjjjjjjjjj
_
Grava limo arcillosa jjjjjjjjjjjjjjj
_ _ _ _ Color café con vetas gris jjjjjjjjjjjjjjj
_
C-2 Arena (F.M.G.) HN>LP jjjjjjjjjjjjjjj
_ _ 4-8-12 _ 20 _ jjjjjjjjjjjjjjj
_
B2 80% GM-GC jjjjjjjjjjjjjjj
___________________
___________________
2 ___________________
___________________ jjjjjjjjjjjjjjj
__
jjjjjjjjjjjjjjj
_ _ _ _ jjjjjjjjjjjjjjj
_
jjjjjjjjjjjjjjj
_ _ _ _ jjjjjjjjjjjjjjj
_
jjjjjjjjjjjjjjj
_ _ _ _ jjjjjjjjjjjjjjj
_
jjjjjjjjjjjjjjj
_ _ _ _ jjjjjjjjjjjjjjj
_
___________________
___________________
3 ___________________
___________________ __
Limo arcillosa
_ _ C-3 _ _ Color gris oscuro _
35-44-50 +50 Arena (F.M.) HN>LP
_ _ B3 80% _ _ _
ML-CL
_ _ _ _ _
C-4
_ _ 70/7cm _ +50 _ _
B4 80%
___________________
___________________
4 ___________________
___________________ __
Fechazo 4 mt
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
5 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
6 ___________________
___________________ _
SACAMUESTRAS TIPO :CUCHARA PESO MARTILLO : 140 LBS CAIDA 30" PROFUNDIDAD DE LA CAPA FREATICA : N.A.
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEOS QUIBDO - ISTMNAS SONDEO: P-6
LOCALIZACION : Ver figura 3 PERFORADOR: Cesar Cajiao FECHA : Enero 2015
_ _ _ _ jjjjjjjjjjjjjjj
_
jjjjjjjjjjjjjjj
_ _ _ _ Grava limo arenosa jjjjjjjjjjjjjjj
_
Color café con vetas grises jjjjjjjjjjjjjjj
_ _ _ _ Gravas (F.G.) y gravillas jjjjjjjjjjjjjjj
_
C-2 jjjjjjjjjjjjjjj
_ _ 5-4-3 _ 7 _ Arena (F.M.G.) HN>LP jjjjjjjjjjjjjjj
_
B2 80% jjjjjjjjjjjjjjj
___________________
___________________
2 ___________________
___________________ GM-GC jjjjjjjjjjjjjjj
__
jjjjjjjjjjjjjjj
_ _ _ _ jjjjjjjjjjjjjjj
_
jjjjjjjjjjjjjjj
_ _ _ _ jjjjjjjjjjjjjjj
_
jjjjjjjjjjjjjjj
_ _ _ _ jjjjjjjjjjjjjjj
_
_ _ _ _ Limo arcilloso _
Color gris oscuro
___________________
___________________
3 ___________________
___________________ Arena (F.M.) HN>LP __
_ _ C-3 _ _ _
10-11-20 31 Arcilla limosa
_ _ B3 80% _ _ Color gris oscuro _
Arena (F.M.) HN>LP
_ _ _ _ _
C-4 CL-ML
_ _ 42-50-70/6cm _ +50 _ _
B4 80%
___________________
___________________
4 ___________________
___________________ __
Fechazo 4 mt
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
5 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
6 ___________________
___________________ _
SACAMUESTRAS TIPO :CUCHARA PESO MARTILLO : 140 LBS CAIDA 30" PROFUNDIDAD DE LA CAPA FREATICA : N.A.
CESCO S.A. REGISTRO DE EXPLORACION DEL SUBSUELO.
COMPAÑIA DE ESTUDIOS DE SUELOS Y DE CONSULTA LTDA.
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEOS QUIBDO - ISTMNAS SONDEO: P-7
LOCALIZACION : Ver figura 3 PERFORADOR: Cesar Cajiao FECHA : Enero 2015
_ _ _ _ _
Limo arenoso
_ _ _ _ Color amarillo con trazas gris _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
3 ___________________
___________________ __
_ _ C-3 _ _ _
8-18-20 38
_ _ B3 80% _ _ _
Arcilla limosa
_ _ _ _ Color gris oscuro _
C-4 Arena (F.M.) HN>LP
_ _ 28-48-60/7cm _ +50 _ CL-ML _
B4 80%
___________________
___________________
4 ___________________
___________________ __
Fechazo 4 mt
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
5 ___________________
___________________ __
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
_ _ _ _ _
___________________
___________________
6 ___________________
___________________ _
SACAMUESTRAS TIPO :CUCHARA PESO MARTILLO : 140 LBS CAIDA 30" PROFUNDIDAD DE LA CAPA FREATICA : N.A.
ANEXO 2-C
RESULTADOS DE LOS
ENSAYOS DE LABORATORIO.
CESCO S.A
DATOS ENSAYOS DE LABORATORIO
OBRA: COLISEOS QUIBDO - ISTMNAS CLIENTE : ZOCALO ARQUITECTURA SAS N. OBRA 15-001 FECHA ene-15
DEO TRA didad(m) /pie) casagrande) P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R. P.M.H.+ R. P.M.S.+ R. P.R.
1 1 0.5-1.0 18 25 346.60 319.90 36.80 68.40 57.50 13.67 26.40 24.43 15.62 26.80 24.90 16.32
2 1.5-2.0 8 26 421.00 364.40 40.60 70.40 55.48 14.16 26.90 24.30 14.96 26.80 24.06 14.19
3 3.0-3.5 2 26 106.40 83.90 14.06 84.80 67.50 15.11 27.80 25.20 16.93 27.40 24.80 14.62
4 4.5-5.0 +50 25 100.4 90.30 15.30 82.20 65.90 15.12 28.10 25.90 15.33 27.80 25.52 14.63
2 1 0.5-1.0 2 24 311.70 269.50 44.70 67.40 54.20 13.96 26.80 24.18 13.96 26.60 24.02 13.88
2 1.5-2.0 +50 25 102.50 92.70 16.75 69.40 56.53 16.83 26.70 24.33 14.29 26.40 24.07 14.16
3 3.0-3.5 +50 25 119.60 110.10 14.39 84.90 67.50 13.69 27.90 25.60 14.18 27.60 25.54 15.38
3 1 0.5-1.0 18 22 96.70 83.90 14.12 78.90 62.60 16.08 28.10 25.80 15.00 27.40 25.08 14.31
2 1.5-2.0 32 25 112.40 100.30 14.35 68.40 54.68 14.08 26.40 24.08 14.65 26.60 24.30 14.91
3 3.0-3.5 +50 25 105.90 95.00 14.44 86.50 68.40 14.10 28.00 25.50 13.95 27.40 25.17 14.92
4 1 0.5-1.0 9 24 149.00 130.40 38.00 69.40 55.43 14.08 26.80 24.30 14.91 26.60 24.16 15.00
2 1.5-2.0 8 25 272.60 227.70 37.90 70.80 56.50 14.62 26.80 24.34 14.74 26.80 24.26 14.36
3 3.0-3.5 +50 25 246.90 217.60 38.40 68.80 54.93 14.93 26.90 24.25 14.66 26.70 24.00 14.16
5 1 0.5-1.0 6 23 368.10 311.90 38.10 70.40 56.03 13.63 27.80 25.02 14.63 27.60 24.77 14.19
2 1.5-2.0 20 25 375.90 336.50 42.50 71.90 58.45 16.29 26.90 24.63 14.63 26.80 24.18 14.19
3 3.0-3.5 +50 26 259.30 239.70 38.10 73.40 58.85 14.61 26.60 23.96 13.67 26.90 24.35 14.36
6 1 0.5-1.0 22 25 383.20 356.70 38.30 67.40 51.24 13.88 26.80 24.40 14.94 26.90 24.46 14.81
2 1.5-2.0 7 26 244.50 216.10 42.40 72.40 57.90 14.81 27.80 25.20 14.84 27.60 25.43 16.83
3 3.0-3.5 +50 25 338.70 305.40 38.30 69.90 56.12 15.37 27.10 24.70 14.55 26.80 24.36 13.96
7 1 0.5-1.0 7 24 333.30 301.90 43.20 70.40 56.50 14.08 26.40 23.95 14.66 26.60 24.00 14.18
2 1.5-2.0 5 22 99.20 73.60 13.95 77.60 57.50 15.30 27.70 24.10 14.06 27.20 23.80 14.29
3 3.0-3.5 38 25 101.60 88.10 15.21 69.70 55.90 14.61 27.10 24.73 14.08 27.40 25.03 14.36
CBR-1 1 0.6-1.0 - 25 209.90 181.90 37.60 81.70 64.50 16.66 27.40 24.60 13.86 29.20 26.64 16.90
CBR-2 1 1.0-1.3 - 25 308.40 279.10 44.40 78.50 61.30 14.81 27.80 25.10 15.04 27.50 24.82 14.86
CBR-3 1 1.5-2.0 - 25 197.9 169.30 37.20 71.50 56.10 15.14 27.50 24.60 13.61 28.80 26.14 16.12
Jefe de Laboratorio:
Jesus Alfonso Meneses
Hoja: Calculo
Página 1 de 2 Archivo:Clasif-USCS.. istiminas
CESCO S.A
RESULTADO DE LOS ENSAYOS DE LABORATORIO.
DEO TRA didad(m) /pie) 2 1½ 1 3/4 1/2 3/8 4 10 40 100 200 % % % % % % USCS
1 1 0.5-1.0 18 100 78.9 66.8 63.3 54 45.7 31.9 13.2 9.43 24.87 22.25 2.62 -4.90 15.29 GM-GC
2 1.5-2.0 8 100 90.8 81.2 50.6 49.2 40 36.9 33.5 21.9 17.48 36.29 27.80 8.49 -1.22 20.66 GM-GC
3 3.0-3.5 2 100 98.1 96.2 92.3 50.3 32.22 33.19 28.49 4.70 0.79 19.20 ML
4 4.5-5.0 +50 100 100 95.6 56.3 13.47 32.10 20.88 11.22 -0.66 18.69 CL-ML
2 1 0.5-1.0 2 100 89 89 86 86 82.5 79.2 72.7 43.6 18.77 32.64 25.54 7.10 -0.95 18.94 SM-SC
2 1.5-2.0 +50 100 100 99.3 90.1 12.90 32.42 23.56 8.86 -1.20 18.84 ML-CL
3 3.0-3.5 +50 100 100 99 80 9.93 32.34 20.21 12.13 -0.85 18.80 CL
3 1 0.5-1.0 18 100 100 99.3 78.7 18.34 34.51 21.42 13.09 -0.23 19.82 CL-ML
2 1.5-2.0 32 100 100 99.1 55.3 14.08 33.79 24.55 9.24 -1.13 19.48 ML-CL
3 3.0-3.5 +50 100 100 97.9 58.9 13.53 33.33 21.70 11.63 -0.70 19.27 CL-ML
4 1 0.5-1.0 9 100 74.6 70.6 55.7 46.9 36.4 23.1 20.13 33.62 26.63 6.99 -0.93 19.40 GM-GC
2 1.5-2.0 8 100 84.6 84.6 73.9 72 64.1 60.3 55.8 41.4 23.66 34.15 25.64 8.50 -0.23 19.65 GM-GC
3 3.0-3.5 +50 100 99.2 98.6 97.2 49.4 16.35 34.68 27.54 7.14 -1.57 19.90 SM-SC
5 1 0.5-1.0 6 100 88.3 81.2 77.3 75.7 60.1 50.6 32.3 18 20.53 33.55 26.75 6.80 -0.92 19.37 SM-SC
2 1.5-2.0 20 100 76.3 54.7 51.6 41.2 35.3 29.1 19.2 13.40 31.90 24.46 7.44 -1.49 18.59 GM-GC
3 3.0-3.5 +50 100 99 97.7 61.4 9.72 33.05 25.59 7.46 -2.13 19.14 ML-CL
6 1 0.5-1.0 22 100 79.7 60.3 36.8 34.4 24.7 19.6 14.4 8.7 8.32 43.25 25.33 17.93 -0.95 23.93 GP-GM
2 1.5-2.0 7 100 81.6 67 60.8 51.6 44.2 37.9 22.6 16.35 33.82 25.16 8.65 -1.02 19.49 GM-GC
3 3.0-3.5 +50 100 99.9 99.4 57.4 12.47 33.82 23.55 10.26 -1.08 19.49 CL-ML
7 1 0.5-1.0 7 100 88.1 55.1 46.9 40.8 32.1 27.2 22.7 13.2 12.14 32.60 26.42 6.18 -2.31 18.92 GM-GC
2 1.5-2.0 5 100 99.5 98.7 69.4 42.92 46.92 35.80 11.11 0.64 25.65 ML
3 3.0-3.5 38 100 100 99.3 66.8 18.52 33.42 22.23 11.19 -0.33 19.31 CL-ML
Jefe de laboratorio:
Jesús Alfonso Meneses
Hoja: Calculo
Página 2 de 2 Archivo:Clasif-USCS.. istiminas
CESCO S.A. COMPAÑIA DE ESTUDIOS DE SUELOS Y CONSULTA
0.005
0.025 18.0 10.6 15.0 8.9
0.05 55.0 32.5 40.0 23.6
0.075 92.0 54.3 66.0 38.9
0.1 124.0 73.2 89.0 52.5
0.15 170.0 100.3 127.0 74.9
0.2 210.0 123.9 158.0 93.2
0.3 275.0 162.3 202.0 119.2
0.4 315.0 185.9 225.0 132.8
0.500 345 203.6 240 141.6
CBR Corregido a
7.3 5.3
0.1" (%)
CBR Corregido a
8.3 6.2
0.2" (%)
Despues
Contenido Húmedo (%) 23.4
Hinchamiento (%) 0.06
150.0
100.0
50.0
0.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Penetracion (pulg)
0.005
0.025 10.0 5.9 11.0 6.5
0.05 39.0 23.0 29.0 17.1
0.075 65.0 38.4 47.0 27.7
0.1 88.0 51.9 64.0 37.8
0.15 128.0 75.5 90.0 53.1
0.2 160.0 94.4 109.0 64.3
0.3 210.0 123.9 138.0 81.4
0.4 248.0 146.3 158.0 93.2
0.500 274 161.7 173 102.1
CBR Corregido a
5.2 3.8
0.1" (%)
CBR Corregido a
6.3 4.3
0.2" (%)
Despues
Contenido Húmedo (%) 25
Hinchamiento (%) 0.06
CBR 2(DESPUES)
150.0
Presion (p.s.i)
100.0
50.0
0.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Penetracion (pulg)
0.005
0.025 11.0 6.5 9.0 5.3
0.05 41.0 24.2 31.0 18.3
0.075 71.0 41.9 53.0 31.3
0.1 98.0 57.8 71.0 41.9
0.15 142.0 83.8 101.0 59.6
0.2 173.0 102.1 119.0 70.2
0.3 217.0 128.0 143.0 84.4
0.4 250.0 147.5 161.0 95.0
0.500 270 159.3 175 103.3
CBR Corregido a
5.8 4.2
0.1" (%)
CBR Corregido a
6.8 4.7
0.2" (%)
Despues
Contenido Húmedo (%) 24.5
Hinchamiento (%) 0.08
CBR 3 (DESPUES)
150.0
Presion (p.s.i)
100.0
50.0
0.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Penetracion (pulg)
7:30 AM
8:00 AM 30 37.40 0.80
1.00 MT
CLIENTE : ZOCALO ARQUITECTURA SAS OBRA : COLISEOS QUIBDO -ISTMNAS PERCOLACION : PER-2
INSPECTOR : CESAR CAJIAO FECHA : ENERO DE 2015 DIMENSION : 0,20 x 0,20
7:10 AM
7:30 AM 30 35.43 0.85
1.00 MT
ANEXO 3-C
REGISTRO FOTOGRÁFICO.
Apique manual para extraer muetra de suelo inalterado para ensayo de CBR
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
Perforaciones exploratorias del suelo mediante la utilización de equipo mecánico a percusión
Apiques manuales para ensayos de percolación