Está en la página 1de 11

UNIVERSIDAD AUTÓNOMA DE SAN LUIS POTOSÍ

FACULTAD DE CIENCIAS QUÍMICAS

LABORATORIO DE INGENIERÍA QUÍMICA

REPORTE DE PRÁCTICAS

LABORATORIO DE TRANSFERENCIA DE MOMENTO

NOMBRE DEL ALUMNO: Sara María Vidales Espinosa

PRÁCTICA No.: 03

NOMBRE DE LA PRÁCTICA: BOMBAS

PROFESOR: Luis Edmundo Silva de los Santos

CLAVE DEL GRUPO:Martes 1:00 pm FECHA: 01-11-22


Tablas de Datos Experimentales
Bomba centrífuga individual
CORRIDA HSUC HDES I t
1 0 26 1 -
2 -2 24 1.64 51.66
3 -5 22 1.75 20.37
4 -10 20 1.84 13.28
5 -13 18 1.89 10.66
6 -19 16 1.96 8.37
7 -25 14 2.02 7.6
8 -29 12 2.04 6.37
9 -35 10 2.09 5.97
10 -42 8 2.11 5.28
11 -46 6 2.14 5.13
12 -50 4 2.15 4.87
13 -52 2 2.1 4.84
14 -52 0 2.05 4.78

Bombas Centrífugas en serie


CORRIDA HSUC HDES I t
1 -1 50 1.54 0
2 -1 48 1.61 52
3 -2 44 1.77 15.19
4 -3 40 1.86 10.5
5 -4 36 1.93 8.47
6 -5 32 1.99 7.31
7 -5.5 28 2.03 6.21
8 -6 24 2.06 5.33
9 -7 20 2.09 4.68
10 -8 16 2.11 4.58
11 -9 12 2.12 4.55
12 -8.5 8 2.1 4.46
13 -8.5 4 2.09 4.37
14 -8.7 0 2 4.22

Bombas de Engranes
FRECUENCIA 50HZ FRECUENCIA 30HZ
CORRIDA %Apertura p_desc I CORRIDA %Apertura p_desc I
kg/cm^2 amp kg/cm^2 amp
1 6.5 0 3.21 1 6.5 0 3.17
2 5.5 0 3.22 2 5.5 0 3.17
3 4.5 0 3.2 3 4.5 0 3.17
4 3.5 0 3.22 4 3.5 0 3.16
5 3 12 3.26 5 3 0 3.15
6 2.5 23 3.38 6 2.5 0 3.15
7 2 33 3.57 7 2 15 3.18
8 1.5 46 4 8 1.5 24 3.18
Algoritmo EES
Algoritmo EES

Carga neta positiva


Tablas de Resultados

BOMBA CENTRÍFUGA INDIVIDUAL


hdesc hsucc vdot t i deltaH Wbomba Welect n
24 -2 0.004452 51.66 1.64 24.27 1046 309.3 338.3
22 -5 0.01129 20.37 1.75 22.68 2507 330 759.5
20 -10 0.01732 13.28 1.84 21.36 3626 347 1045
18 -13 0.02158 10.66 1.89 19.77 4181 356.5 1173
16 -19 0.02748 8.37 1.96 18.58 5007 369.7 1355
14 -25 0.03026 7.6 2.02 17.4 5163 381 1355
12 -29 0.03611 6.37 2.04 15.94 5645 384.7 1467
10 -35 0.03853 5.97 2.09 14.76 5576 394.2 1415
8 -42 0.04356 5.28 2.11 13.71 5857 397.9 1472
6 -46 0.04483 5.13 2.14 12.25 5388 403.6 1335
4 -50 0.04723 4.87 2.15 10.8 5001 405.5 1233
2 -52 0.04752 4.84 2.1 9.07 4227 396.1 1067
0 -52 0.04812 4.78 2.05 7.07 3336 386.6 862.8

BOMBA CENTRÍFUGA EN SERIE


Hdesc Hsucc I t Vdot Wbomb Welect delta H n
48 -1 1.61 52 0.00009615 45.61 607.3 49 3.755
44 -2 1.77 15.19 0.0003292 148.4 667.6 46 11.11
40 -3 1.86 10.5 0.0004762 200.7 701.6 43 14.31
36 -4 1.93 8.47 0.0005903 231.5 728 40 15.9
32 -5 1.99 7.31 0.000684 248.2 750.6 37 16.53
28 -5.5 2.03 6.21 0.0008052 264.5 765.7 33.5 17.27
24 -6 2.06 5.33 0.0009381 276 777 30 17.76
20 -7 2.09 4.68 0.001068 282.9 788.3 27 17.94
16 -8 2.11 4.58 0.001092 256.9 795.9 24 16.14
12 -9 2.12 4.55 0.001099 226.3 799.7 21 14.15
8 -8.5 2.1 4.46 0.001121 181.4 792.1 16.5 11.45
4 -8.5 2.09 4.37 0.001144 140.3 788.3 12.5 8.896
0 -8.7 2 4.22 0.001185 101.1 754.4 8.7 6.7
Tablas de Resultados

ENGRANES 30HZ
Pdesc Avalv I f Flujo_vol(min) Hbomba Pelect Phidr n
0 1 3.17 30 4.735 0 576.2 0 0
0 0.8462 3.17 30 4.006 0 576.2 0 0
0 0.6769 3.17 30 3.205 0 576.2 0 0
0 0.5385 3.16 30 2.549 0 574.4 0 0
0 0.4615 3.15 30 2.185 0 572.6 0 0
0 0.3846 3.15 30 1.821 0 572.6 0 0
213.3 0.3077 3.18 30 1.457 180.3 578 35.72 6.179
341.4 0.2308 3.28 30 1.093 288.5 596.2 42.86 7.188

ENGRANES 50HZ
Pdesc Avalv I f Flujo_vol(min) Hbomba Pelect Phidr n
0 1 3.21 50 7.891 0 583.5 0 0
0 0.8462 3.22 50 6.677 0 585.3 0 0
0 0.6769 3.2 50 5.341 0 581.7 0 0
0 0.5385 3.22 50 4.249 0 585.3 0 0
170.7 0.4615 3.26 50 3.642 144.2 592.6 71.43 12.05
327.1 0.3846 3.38 50 3.035 276.4 614.4 114.1 18.57
469.4 0.3077 3.57 50 2.428 396.6 648.9 131 20.18
654.3 0.2308 4 50 1.821 552.9 727.1 136.9 18.83
Gráficas centrífugas individual

Relación Wbomba y Weléctrica vs Flujo Volumétrico


7000

6000

5000
Wbomba, Welect

4000

3000 Wbomb
Welect
2000

1000

0
0 0.01 0.02 0.03 0.04 0.05 0.06
Flujo volumétrico
Gráficas centrífugas en serie

Relación H BÓMBA ÚTIL Y EFICIENCIA vs FLUJO


VOLUMÉTRICO
60

50
H bomb útil, n

40

30
H
20
n
10

0
0 0.0002 0.0004 0.0006 0.0008 0.001 0.0012 0.0014
FLUJO vol (m/s)

Relación Wbomba y Weléctrica vs flujo


900 volumétrico
800
Wbomba y Weléctrica

700
600
500
400
Wbomb
300
200 Welect
100
0
0 0.0002 0.0004 0.0006 0.0008 0.001 0.0012 0.0014
Flujo vol
Gráficas Bomba de Engranes
Gráficas Bomba de Engranes
Gráficas carga neta positiva

También podría gustarte