Documentos de Académico
Documentos de Profesional
Documentos de Cultura
PROYECTO PRIE
ANALISIS Y DISEÑO DE ESTRUCTURA PARA GRUA
INGENIERO:
FRANKLIN CASTELLANOS MELO
PRESENTADO A:
INGENIERA ANA MILENA OLARTE ARENAS
MATRIZ DE RIGIDEZ
UX1 UY1 UX2 UY2 UX3 UY3 UX4 UY4 UX5 UY5 UX6 UY6
641285,2008 2,91038E-11 -4711799,382 0 4463809,941 0 -393295,7596 -2,91038E-11 0 0 0 0 UX1
0 0 0 0 0 0 0 0 0 0 0 0 UY1
-4711799,382 0 247989,4412 0 0 0 4463809,941 0 0 0 0 0 UX2
0 0 0 0 0 0 0 0 0 0 0 0 UY2
4463809,941 0 0 0 5105095,142 2,91038E-11 -4711799,382 0 -4463809,941 0 -393295,7596 -2,91038E-11 UX3
0 0 0 0 0 0 0 0 0 0 0 0 UY3
-393295,7596 -2,91038E-11 4463809,941 0 -4711799,382 0 -3822524,74 2,91038E-11 0 0 4463809,941 0 UX4
0 0 0 0 0 0 0 0 0 0 0 0 UY4
0 0 0 0 -4463809,941 0 0 0 9175609,323 0 -4711799,382 0 UX5
0 0 0 0 0 0 0 0 0 0 0 0 UY5
0 0 0 0 -393295,7596 -2,91038E-11 4463809,941 0 -4711799,382 0 641285,2008 2,91038E-11 UX6
0 0 0 0 0 0 0 0 0 0 0 0 UY6
Estructura inestable, los apoyos como se propone analizarlo propone condiciones de apoyo inadecuadas por lo que el resultado son
condiciones de rigidez de cero o negativas.
NODO 2
Fx = -6,15 + R2x = R2x= 6,15 tonf = 60,31 kn
Fy = 6,93 + 2,35= 9,28 tonf = 91,01 kn
NODO 3
Fx = -4,23 + 0,56 sen 45 = 3,83 tonf = 37,56 kn
Fy = 0,23 + 0,13 – 0,56 cos 45 = -0,036 tonf = -0,35 kn
NODO 4
Fx = 4,23 – 6,15 cos 45 = -0,11 tonf = -1,07 kn
Fy = -2,26 -2,26 + 6,15 sen 45 = -0,17 tonf = -1,66 kn
NODO 5
Fx = -1,92 tonf
Fy = 0,13 tonf
6
NODO 6
Fx = 1,53 -0,57 cos 45 + 1,92 = 3,04 tonf
Fy = 0,57 sen 45 + 2,35 = 2,75 tonf
1 2
𝑏 ∗ ℎ 3 220 ∗ 2203
𝐼= = = 195213333,3
12 12
𝑀𝑐 38119840 ∗ 110
𝜎= = = 21,48 𝑁/𝑚𝑚^2
𝐼 195213333,3
𝑏 ∗ ℎ 3 220 ∗ 2203
𝐼= = = 195213333,3
12 12
𝑀𝑐 37658426,67 ∗ 110
𝜎= = = 21,22 𝑁/𝑚𝑚^2
𝐼 195213333,3
3 4
𝑏 ∗ ℎ 3 220 ∗ 2203
𝐼= = = 195213333,3
12 12
𝑀𝑐 37658426,67 ∗ 110
𝜎= = = 21,22 𝑁/𝑚𝑚^2
𝐼 195213333,3
𝑏 ∗ ℎ 3 220 ∗ 2203
𝐼= = = 195213333,3
12 12
𝑀𝑐 3,73 𝐸 − 9 ∗ 110
𝜎= = = 0 𝑁/𝑚𝑚^2
𝐼 195213333,3
3 4
3 DISEÑO DE CONEXIONES
• Utilizamos pernos A325 de ½ in con un esfuerzo admisible de 372
Mpa.
Area de 126,68 mm^2
ELEMENTO 1
𝜋
𝐴𝑝𝑒𝑟𝑛𝑜 = 𝑥 (12,72 ) = 126,68 𝑚𝑚2
4
60310 𝑁
𝜏= = 119,02 𝑀𝑝𝑎 < 372 𝑀𝑝𝑎 CUMPLE
4∗(126,68)
60310
𝐹 𝐴𝑥𝑖𝑎𝑙 𝑝𝑜𝑟 𝑝𝑒𝑟𝑛𝑜 = = 15077,5 𝑁
4
60310 𝑁
𝑉𝑝𝑙𝑎𝑡𝑖𝑛𝑎 = = 104 𝑀𝑝𝑎 < 248,10 𝑀𝑝𝑎 CUMPLE
12 𝑋 12
18
ELEMENTO 3
2214,57
𝐹 𝐴𝑥𝑖𝑎𝑙 𝑝𝑜𝑟 𝑝𝑒𝑟𝑛𝑜 = = 557,64 𝑁
4
2214,57 𝑁
𝑉𝑝𝑙𝑎𝑡𝑖𝑛𝑎 = = 15,37 𝑀𝑝𝑎 < 248,10 𝑀𝑝𝑎 CUMPLE
12 𝑋 12
19
ELEMENTO 2
𝜋
𝐴𝑝𝑒𝑟𝑛𝑜 = 𝑥 (12,72 ) = 126,68 𝑚𝑚2
4
60187,02𝑁
𝜏= = 158,37 𝑀𝑝𝑎 < 372 𝑀𝑝𝑎 CUMPLE
3∗(126,68)
60187,02
𝐹 𝐴𝑥𝑖𝑎𝑙 𝑝𝑜𝑟 𝑝𝑒𝑟𝑛𝑜 = = 𝑁
3
60310 𝑁
𝑉𝑝𝑙𝑎𝑡𝑖𝑛𝑎 = = 104 𝑀𝑝𝑎 < 248,10 𝑀𝑝𝑎 CUMPLE
12 𝑋 12
20
ELEMENTO 4
𝜋
𝐴𝑝𝑒𝑟𝑛𝑜 = 𝑥 (12,72 ) = 126,68 𝑚𝑚2
4
23000 𝑁
𝜏= = 45,39 𝑀𝑝𝑎 < 372 𝑀𝑝𝑎 CUMPLE
4∗(126,68)
23000
𝐹 𝐴𝑥𝑖𝑎𝑙 𝑝𝑜𝑟 𝑝𝑒𝑟𝑛𝑜 = = 5750 𝑁
4
5750 𝑁
𝑉𝑝𝑙𝑎𝑡𝑖𝑛𝑎 = = 39,93 𝑀𝑝𝑎 < 248,10 𝑀𝑝𝑎 CUMPLE
12 𝑋 12
22
𝑅 = √(60265,982 +67991,82 )
R= 90856,33 N
𝜋
𝐴𝑝𝑒𝑟𝑛𝑜 = 𝑥 (12,72 ) = 126,68 𝑚𝑚2
4
90856,33 𝑁
𝜏= = 239,07 𝑀𝑝𝑎 < 372 𝑀𝑝𝑎 CUMPLE
3∗(126,68)
90856,33
𝐹 𝐴𝑥𝑖𝑎𝑙 𝑝𝑜𝑟 𝑝𝑒𝑟𝑛𝑜 = = 30285,44 𝑁
3
30285,44 𝑁
𝑉𝑝𝑙𝑎𝑡𝑖𝑛𝑎 = = 210,31 𝑀𝑝𝑎 < 248,10 𝑀𝑝𝑎 CUMPLE
12 𝑋 12
23
𝜋
𝐴𝑝𝑒𝑟𝑛𝑜 = 𝑥 (12,72 ) = 126,68 𝑚𝑚2
4
90856,33 𝑁
𝜏= = 358,60 𝑀𝑝𝑎 < 896 𝑀𝑝𝑎 CUMPLE
2∗(126,68)
90856,33
𝐹 𝐴𝑥𝑖𝑎𝑙 𝑝𝑜𝑟 𝑝𝑒𝑟𝑛𝑜 = = 45428,165 𝑁
2
45428,165 𝑁
𝑉𝑝𝑙𝑎𝑡𝑖𝑛𝑎 = = 157,73 𝑀𝑝𝑎 < 496,2 𝑀𝑝𝑎 CUMPLE
2 𝑥 (12 𝑋 12)
Se utiliza doble platina pegada a la viga atornillada con 2 tornillos A490 para
la conexión con la viga en los dos apoyos para garantizar rigidez utilizamos
los mismos elementos y materiales.
24
5 REVISION DE VIGA
La viga simplemente apoyada en una luz L = 7,92 m, de dimensiones 200 mm x 450 mm, a
construirse en concreto reforzado de f’c = 21.1 Mpa y acero de refuerzo Fy = 240 Mpa, sometida a
una carga ultima φMn = 45,42 kN*m. Se supone que se ancla en la mitad de la viga.
90856,33 45428,15
φMn= = = 45,42
2 1000
𝐹𝑦
Mn = ФFy ∗ 𝛒 1 − 0.59𝑓´𝑐 𝝆 𝑏𝑑
240000
45,42 = 0,90*240000 ∗ 𝛒 (1 − 0.59 21100 ) 𝝆 0,20 * 0,45
𝛒𝟏 = 0.0023 𝛒𝟐 = 0.1598
Tomamos ρ = 0.0023
Colocamos de manera continua la mitad del area calculada As = 207 mm2/2 = 103 mm2
CONCLUSIONES Y RECOMENDACIONES
• Se aprueban las secciones tubulares A500 ya que cumplen con las licitaciones.
• Platina de acero ASTM A36 Limite de fluencia de 2530 Kg/𝑐𝑚2 = 248,10 Mpa
espesor de 12 mm DE ½ in.
• Para la conexión de la grúa y la viga se debe instalar doble platina como se diseñó
en los cálculos para cuidarnos de esfuerzos cortantes.