Está en la página 1de 2

DISEÑO COLUMNAS EN VOLADIZO BLOQUE D

COLUMNA TIPO 2

Nivel Sección L
Refuerzo
(m) b (m) h (m) (m)
N +6.15 0.40 0.55 2.70 6#8+ 4#6
N +3.45 0.40 0.55 4.30 6#8+ 4#6

Ro = 2.5 Muro
Aa = 0.2 e= 0.15 m
LAferente = 4.05 m S= 1.5 g= 1.80 t/m³
Nivel Cargas (t) I= 1.1

N +6.15 PPropio Viga = 2.673 t Sa = 0.55


PPropio Col = 0.713 t
Cubierta = 0.729 t
Muro = 1.476 t Pt = 5.591 t

N +3.45 PPropio Viga = 2.673 t


PPropio Col = 1.848 t
Muro = 3.827 t Pt = 8.348 t

PTotal = 13.94 t

Pu = -20.91 t

VB = 11.500 t

Nivel ht (m) Wt Wt x ht cv Vi Vd
N +6.15 7.00 5.591 39.14 0.522 6.00 2.40
N +3.45 4.30 8.348 35.90 0.478 5.50 2.20
Σ= 75.03

Mu = 26.26 t-m r = 0.0076490 As = 15.30 cm²


Vu2
Refuerzo
Barra # Cantidad
Mu 8 3
Vu1
L
Refuerzo Longitudinal = 3 f'c = 210.0 kg/cm²
#8 Fy = 4,200.0 kg/cm²

Mu

Diseño Por Cortante


Vu = 4.600 t
ø= 0.85
Vc = 14.282 t

Vc >= Vu ok!!! Colocar Flejes # 4 c/.10 en Zonas de Confinamiento


Colocar Flejes # 4 c/.15 en Resto de la Luz
COLUMNA TIPO 3

Nivel Sección L
Refuerzo
(m) b (m) h (m) (m)
N +6.00 0.40 0.80 2.70 8#8+ 6#6
N +2.95 0.40 0.80 4.30 8#8+ 6#6

Ro = 2.5 Muro
Aa = 0.2 e= 0.15 m
LAferente = 4.50 m S= 1.5 g= 1.80 t/m³
Nivel Cargas (t) I= 1.1

N +6.15 PPropio Viga = 2.970 t Sa = 0.55


PPropio Col = 1.037 t
Cubierta = 4.290 t
Muro = 1.640 t Pt = 9.937 t

N +3.45 PPropio Viga = 2.970 t


PPropio Col = 2.688 t
Cubierta = 0.000 t
Muro = 4.253 t Pt = 9.911 t

PTotal = 19.85 t

Pu = -29.77 t

VB = 16.374 t

Nivel ht (m) Wt Wt x ht cv Vi Vd
N +6.15 7.00 9.937 69.56 0.620 10.15 4.06
N +3.45 4.30 9.911 42.62 0.380 6.22 2.49
Σ= 112.17

Mu = 39.13 t-m r = 0.0048870 As = 14.66 cm²

Vu2
Refuerzo
Barra # Cantidad
Mu 8 4
Vu1
L Refuerzo Longitudinal = 4 f'c = 210.0 kg/cm²
#8 Fy = 4,200.0 kg/cm²

Mu

Diseño Por Cortante


Vu = 6.550 t
ø= 0.85
Vc = 20.774 t

Vc >= Vu ok!!! Colocar Flejes # 4 c/.10 en Zonas de Confinamiento


Colocar Flejes # 4 c/.15 en Resto de la Luz