TEMPERATURA DE ROCIO
TEMPERATURA SUPERFICIAL INTERIOR
Ʈ= Rsi . Δt Θ= Ti-Ʈ
RT
EJEMPLO:
HUMEDAD RELATIVA: 70%
TEMPERATURA AMBIENTE: 18°c
TEMPERATURA SUPERFICIAL INTERIOR: 15°c Θ= Ti-Ʈ Ʈ= Rsi . Δt
RT
BUSCO EN EL DIAGRAMA PSICOMETRICO
TEMPERATURA ROCIO: 12.5°c
2
4/10/2019
3
4/10/2019
VERIFICACION DE RIESGO DE
CONDENSACION INTERSTICIAL
Nº CAPAS Espe- Conduc- Resist. Peso Peso Permea- Per- Resist. Presión Temp. Temp.
sor tividad térmica Espec. Unit. bilidad meancia vapor tot. vapor real rocío
g/m.h.K g/m2.h.kP m2.h.kPa/
Elem. m W/m.K m2.K/W Kg/m3 Kg/m2 Pa a g kN/m2 (°C) (°C)
Ver Ver Ver
AIRE INTERIOR Planilla Planilla Planilla 1.31 18.00
CONDU
R.S.I. C 0.130 PERM PERM
1.31 15.79 11.14
1 LADRILLO VISTO 0.1200 0.910 0.132 1800 216.0 0.080 1.50
0.97 13.55 6.59
POLIESTIRENO
2 EXPANDIDO 0.0300 0.037 0.811 20 0.6 0.090 0.33
0.90 -0.24 5.37
3 AZOTADO HIDROFUGO 0.0050 1.130 0.004 1900 9.5 0.044 0.11
0.87 -0.31 4.93
4 LADRILLO COMUN 0.1200 0.810 0.148 1600 192.0 0.080 1.50
0.53 -2.83 -1.93
5 REVOQUE GRUESO 0.0200 0.930 0.022 1900 38.0 0.044 0.45
0.42 -3.20 -4.46
6 REVOQUE FINO 0.0050 0.700 0.007 1900 9.5 0.044 0.11
0.40 -3.32 -5.13
0.40 -4.00
R.S.E. 0.040
AIRE EXTERIOR 0.40 -4.00
Res.Ter.T Resis.paso vapor
ot. K=1/Rt Peso Total tot.
Espesor Total: 0.300 1.294 0.773 465.60 4.015
4
4/10/2019
VERIFICACION DE RIESGO DE
CONDENSACION INTERSTICIAL
18,00
20,00
15,79
13,55
15,00
10,00
11,14
5,37
4,93
6,59
5,00
-0,24
-0,31
-3,20
-3,32
-4,00
-5,00
-4,46
-5,13
-10,00
POLIESTIRENO EXPANDIDO
REVOQUE FINO
LADRILLO VISTO
0
Aire interior
Superficie esxterior
AZOTADO HIDROFUGO
LADRILLO COMUN
REVOQUE GRUESO
VERIFICACION DE RIESGO DE
CONDENSACION INTERSTICIAL
Nº CAPAS Espe- Conduc- Resist. Peso Peso Permea-
Resist. Presión Temp. Temp. Per-
vapor
sor tividad térmica Espec. Unit. bilidad meancia tot. vapor real rocío
g/m.h.K g/m2.h.kP m2.h.kPa
Elem. m W/m.K m .K/W Kg/m Kg/m
2 3 2 Pa a /g kN/m2 (°C) (°C)
Ver Ver Ver
AIRE INTERIOR Planilla Planilla Planilla 1.31 18.00
CONDU
R.S.I. C 0.130 PERM PERM
1.31 15.79 11.14
1 LADRILLO VISTO 0.1200 0.910 0.132 1800 216.0 0.080 1.50
1.29 13.56 10.90
2 FILM POLIETILENO 0.0015 0.500 0.003 960 1.4 0.0160 62.50
0.43 13.51 -4.24
POLIESTIRENO
3 EXPANDIDO 0.0300 0.037 0.811 20 0.6 0.090 0.33
0.43 -0.25 -4.36
4 AZOTADO HIDROFUGO 0.0050 1.130 0.004 1900 9.5 0.044 0.11
0.43 -0.32 -4.40
5 LADRILLO COMUN 0.1200 0.810 0.148 1600 192.0 0.080 1.50
0.41 -2.84 -4.93
6 REVOQUE GRUESO 0.0200 0.930 0.022 1900 38.0 0.044 0.45
0.40 -3.20 -5.09
7 REVOQUE FINO 0.0050 0.700 0.007 1900 9.5 0.044 0.11
0.40 -3.32 -5.13
0.40 -4.00
R.S.E. 0.040
AIRE EXTERIOR 0.40 -4.00
Res.Ter.T Resis.paso vapor
ot. K=1/Rt Peso Total tot.
Espesor Total: 0.302 1.297 0.771 467.04 66.515
5
-5,00
0,00
5,00
-10,00
10,00
15,00
20,00
Aire interior 18,00
0 -5,13 -3,32
CONFORT HIGROTERMICO
VERIFICACION DE RIESGO DE
CONDENSACION INTERSTICIAL
TEMP. REAL
TEMP. ROCIO
6
4/10/2019
4/10/2019
CONFORT HIGROTERMICO
AIRE:
• HUMEDAD
• TEMPERATURA
• VELOCIDAD
EQUILIBRIO
HOMEOTERMICO
SENSACION DE
BIENESTAR
CONFORT HIGROTERMICO
ENERGIA CALORICA
7
4/10/2019
CONFORT HIGROTERMICO
CONFORT HIGROTERMICO
8
4/10/2019
CONFORT HIGROTERMICO
ACONDICIONAMIENTO
9
4/10/2019
10
4/10/2019
ACONDICIONAMIENTO
QT= Qt+Qe
Zd: coeficiente por interrupción del servicio Ze: coeficiente por orientación
Ininterrumpido 7% E, O: 0%
De 8 a 12 hs 15% N, NE, NO: -5%
De 12 a 16 hs 25% SO, S, SE: +5%
Zh: entre 0,05 y 0,1 Se considera la orientación del local
11
4/10/2019
Qe: W
Nr: renovaciones de aire
Sin paredes exteriores: 0,5
Una pared exterior con abertura normal: 1
Dos paredes ext. Con aberturas normales o una grande: 1,5
Con mas paredes exteriores: 2
12
4/10/2019
Desarrollo: Tomando como base la vivienda del trabajo practico No. 1, realizar el
balance térmico para condiciones de invierno y calcular la energía necesaria para
mantener las condiciones de confort en toda la vivienda, ubicada en Rosario y con
temperatura exterior de diseño 18°c y exterior -4°c
13