Está en la página 1de 4

Totally Integrated

Automation Portal

Neumatica / PLC_1 [CPU 1212C AC/DC/Rly] / Bloques de programa


Main [OB1]
Main Propiedades
General
Nombre Main Número 1 Tipo OB Idioma KOP
Numeración Automático
Información
Título "Main Program Sweep (Cy‐ Autor Comentario Familia
cle)"
Versión 0.1 ID personaliza‐
da

Main
Nombre Tipo de datos Valor predet. Supervisión Comentario
Temp
Constant

Segmento 1:

%I0.7 %I0.0 %M3.0 %M1.1 %M1.5 %M1.0


"STOP" "PB1" "OFF1" "ON2" "ON3" "ON1"

%M1.0
"ON1"

%I0.1 %M3.1 %M1.0 %M1.5 %M1.1


"PB2" "OFF2" "ON1" "ON3" "ON2"

%M1.1
"ON2"

%I0.2 %M3.2 %M1.0 %M1.1 %M1.5


"PB3" "OFF3" "ON1" "ON2" "ON3"

%M1.5
"ON3"

Segmento 2:

%M1.0 %I0.3 %M1.4 %M1.2


"ON1" "A0" "R3" "R1"

%M3.5
"ON1+"

%M1.2
"R1"

%I0.6 %M1.2 %M1.3


"B1" "R1" "R2"

%M1.3
"R2"

%M1.3 %I0.5 %M1.4


"R2" "B0" "R3"

Segmento 3:
Totally Integrated
Automation Portal

%M1.1 %I0.3 %M4.1 %M4.0


"ON2" "A0" "K2" "K1"

%M3.6
"ON2+"

%M4.0
"K1"

%I0.6 %I0.5 %M4.1


"B1" "B0" "K2"

%M4.1
"K2"

Segmento 4:

%M1.5 %I0.5 %M2.0 %M1.7 %M1.6


"ON3" "B0" "X3" "X2" "X1"

%M3.7
"ON3+"

%M1.6
"X1"

%M1.6 %I0.6 %M2.0 %M1.7


"X1" "B1" "X3" "X2"

%M1.7
"X2"

%M1.7 %I0.3 %M2.1 %M2.0


"X2" "A0" "X4" "X3"

%M2.0
"X3"

%M2.0 %I0.6 %M1.6 %M2.1


"X3" "B1" "X1" "X4"

%M2.1
"X4"

Segmento 5:
Totally Integrated
Automation Portal

%M4.0 %M1.1 %Q0.0


"K1" "ON2" "1Y1"

%M1.2 %M1.0
"R1" "ON1"

%M1.6 %M1.5
"X1" "ON3"

%I0.5 %M1.7
"B0" "X2"

%I0.4 %M4.1 %M4.0 %M1.1 %Q0.1


"A1" "K2" "K1" "ON2" "2Y1"

%I0.4 %M1.3 %M1.2 %M1.0


"A1" "R2" "R1" "ON1"

%M1.6 %I0.4 %M2.0 %M1.5


"X1" "A1" "X3" "ON3"

%M2.0 %M1.6
"X3" "X1"

%M4.1 %M1.1 %Q0.2


"K2" "ON2" "2Y2"

%M1.3 %M1.0
"R2" "ON1"

%M1.7 %M2.1 %M1.5


"X2" "X4" "ON3"

%M2.1 %M1.7
"X4" "X2"

Segmento 6:

%DB1
"IEC_Counter_
0_DB"

%M1.0 %Q0.0 CTU %M3.0


"ON1" "1Y1" Int "OFF1"
CU Q
%I0.0 CV ...
"PB1" R
1 PV

%DB2
"IEC_Counter_
0_DB_1"

%M1.1 %Q0.0 CTU %M3.1


"ON2" "1Y1" Int "OFF2"
CU Q
%I0.1 CV ...
"PB2" R
1 PV

%DB3
"IEC_Counter_
0_DB_2"

%M1.5 %Q0.0 CTU %M3.2


"ON3" "1Y1" Int "OFF3"
CU Q
%I0.2 CV ...
"PB3" R
1 PV

Segmento 7:
Totally Integrated
Automation Portal

%M3.3
%Q0.0 "CilindroA" %M3.3
"1Y1" SR "CilindroA"
S Q

%Q0.0
"1Y1"
R1

%M3.4
%Q0.0 "CilindroB" %M3.4
"1Y1" SR "CilindroB"
S Q

%Q0.2
"2Y2"
R1

%DB5
"IEC_Counter_
0_DB_4"

%M3.3 %M0.7 %Q0.0 CTUD


"CilindroA" "Clock_0.5Hz" "1Y1" Int
CU QU
QD ...
%M3.3 %M0.7 %Q0.0 %MW100
"CilindroA" "Clock_0.5Hz" "1Y1" CV "POSA"
CD
false R
false LD
10 PV

%DB6
"IEC_Counter_
0_DB_5"

%M3.4 %M0.7 %Q0.1 CTUD


"CilindroB" "Clock_0.5Hz" "2Y1" Int
CU QU
QD ...
%M3.4 %M0.7 %Q0.2 %IW200
"CilindroB" "Clock_0.5Hz" "2Y2" CV "POSB"
CD
false R
false LD
10 PV

También podría gustarte