Calculos P1
Calculos P1
INFORMACIÓN DE LA BOMBA
Diámetro de tubería 1.5 pulg
Brazo 21 cm
Diámetro de tubo venturi 1.28 pulg
RPM 2000
SECUENCIA DE CÁLCULOS
1. Gasto Volumétrico Teórico.
V
Q=
tiempo
0.04 m3 m3
Q1 = = 8.4706
0.0047 h h
0.04 m3 m3
Q2 = =9
0.0044 h h
0.04 m3 m3
Q3 = = 9.2308
0.0043 h h
0.04 m3 m3
Q4 = = 10.8679
0.0037 h h
0.04 m3 m3
Q5 = = 11.0769
0.0036 h h
0.04 m3 m3
Q6 = = 12
0.0033 h h
0.04 m3 m3
Q7 = = 13.0909
0.0031 h h
𝐾𝑔 𝐾𝑔
0.7 2 − 0.1142 2
𝐻𝑚1 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 6.0967 𝑚
0.98
𝐾𝑔 𝐾𝑔
0.54 2 − 0.1496 2
𝐻𝑚2 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 4.0633 𝑚
0.98
𝐾𝑔 𝐾𝑔
0.38 2 − 0.1904 2
𝐻𝑚3 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 1.9734 𝑚
0.98
𝐾𝑔 𝐾𝑔
0.28 2 − 0.2176 2
𝐻𝑚4 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 0.6495 𝑚
0.98
𝐾𝑔 𝐾𝑔
0.22 2 − 0.2380 2
𝐻𝑚5 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 0.1873 𝑚
0.98
𝐾𝑔 𝐾𝑔
0.18 2 − 0.2584 2
𝐻𝑚6 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 0.8160 𝑚
0.98
𝐾𝑔 𝐾𝑔
0.162 − 0.2584 𝑐𝑚 2
𝐻𝑚7 = 𝑐𝑚 ∗ 10.2 = 1.0242 𝑚
0.98
𝐾𝑔 𝐾𝑔
0.16 2 − 0.2584 2
𝐻𝑚8 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 1.0242 𝑚
0.98
Q vs H
14.0000
13.0000
12.0000
Q (m3/h)
11.0000
10.0000
9.0000
8.0000
0.0000 0.5000 1.0000 1.5000 2.0000 2.5000 3.0000 3.5000 4.0000 4.5000
H (m)
Q vs H
Q vs n
14.0000
12.0000
10.0000
Q (m3/h)
8.0000
6.0000
4.0000
2.0000
0.0000
0.0000 5.0000 10.0000 15.0000 20.0000 25.0000 30.0000 35.0000
H (m)
BOMBA DE DESPLAZAMIENTO POSITIVO
INFORMACIÓN DE LA BOMBA
Diámetro de tanque 23.2 cm Diámetro de tanque 5.8 cm
grande pequeño
Diferencia de altura 10 cm Diámetro del vástago 11 cm
Diámetro de pistón 4.45 cm Diámetro de la boquilla 10 cm
Brazo 21 cm carrera 41.33 cm
velocidad 900 rpm Banda de transmisión 72 dientes diámetro mayor
14 dientes diámetro menor
SECUENCIA DE CÁLCULOS
900𝑟𝑝𝑚 ∗ 14 𝑑𝑖𝑒𝑛𝑡𝑒𝑠
𝑅𝑃𝑀2 = = 175 𝑟𝑝𝑚
72 𝑑𝑖𝑒𝑛𝑡𝑒𝑠
2. Cálculo del Volumen total
𝜋
𝑉𝑃𝐼𝑆𝑇Ó𝑁 = ∗ 𝐷2 ∗ 𝑐𝑎𝑟𝑟𝑒𝑟𝑎
4
𝑉𝑃𝐼𝑆𝑇Ó𝑁 = 0.785 ∗ (0.0445𝑚)2 ∗ 0.413𝑚 = 6.42𝑋10−4 𝑚3
𝜋
𝑉𝑉Á𝑆𝑇𝐴𝐺𝑂 = ∗ 𝐷2 ∗ 𝑐𝑎𝑟𝑟𝑒𝑟𝑎
4
𝑉𝑉Á𝑆𝑇𝐴𝐺𝑂 = 0.785 ∗ (0.011𝑚)2 ∗ 0.413𝑚 = 3.923𝑋10−5 𝑚3
𝐾𝑔 𝐾𝑔
0 2 − 0.0748
𝐻𝑚1 = 𝑐𝑚 𝑐𝑚2 ∗ 10.2 = −0.7785 𝑚
0.98
𝐾𝑔 𝐾𝑔
0.4 2 − 0.0748 2
𝐻𝑚2 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 3.3847 𝑚
0.98
𝐾𝑔 𝐾𝑔
0.8 2 − 0.068 2
𝐻𝑚3 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 7.6188 𝑚
0.98
𝐾𝑔 𝐾𝑔
1.2 2 − 0.068 2
𝐻𝑚4 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 11.782 𝑚
0.98
𝐾𝑔 𝐾𝑔
1.6 2 − 0.068 2
𝐻𝑚5 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 15.9453 𝑚
0.98
𝐾𝑔 𝐾𝑔
2 2 − 0.068 2
𝐻𝑚6 = 𝑐𝑚 𝑐𝑚 ∗ 10.2 = 20.1086 𝑚
0.98
𝑄 ∗ 𝛾 ∗ 𝐻𝑚
𝑃𝐻 =
367
𝑚3 𝐾𝑔
1.0731 ∗1 ∗ 0.7785 𝑚
𝑃𝐻1 = ℎ 𝑑𝑚 = 0.0023 𝐾𝑊
367
𝑚3 𝐾𝑔
1.0811 ∗1 ∗ 3.3847 𝑚
𝑃𝐻2 = ℎ 𝑑𝑚 = 0.01000 𝐾𝑊
367
𝑚3 𝐾𝑔
1.0838 ∗1 ∗ 7.6188 𝑚
𝑃𝐻3 = ℎ 𝑑𝑚 = 0.0225 𝐾𝑊
367
𝑚3 𝐾𝑔
1.0883 ∗1 ∗ 11.7820 𝑚
𝑃𝐻4 = ℎ 𝑑𝑚 = 0.0349 𝐾𝑊
367
𝑚3 𝐾𝑔
1.1287 ∗1 ∗ 15.9453 𝑚
𝑃𝐻5 = ℎ 𝑑𝑚 = 0.0490 𝐾𝑊
367
𝑚3 𝐾𝑔
1.1336 ∗1 ∗ 20.1086 𝑚
𝑃𝐻6 = ℎ 𝑑𝑚 = 0.0621 𝐾𝑊
367
𝑀 = 𝐹𝑢𝑒𝑟𝑧𝑎 ∗ 𝐶𝑎𝑟𝑟𝑒𝑟𝑎
𝑀1 = 3.4335 𝑁 ∗ 0.413 𝑚 = 1.4180 𝑁𝑚
𝑀2 = 4.0221 𝑁 ∗ 0.413 𝑚 = 1.6611 𝑁𝑚
𝑀3 = 5.3955 𝑁 ∗ 0.413 𝑚 = 2.2283 𝑁𝑚
𝑀4 = 6.4746 𝑁 ∗ 0.413 𝑚 = 2.6740 𝑁𝑚
𝑀5 = 8.0442 𝑁 ∗ 0.413 𝑚 = 3.3223 𝑁𝑚
𝑀6 = 8.1423 𝑁 ∗ 0.413 𝑚 = 3.3628 𝑁𝑚
0.0023 𝐾𝑊
𝜂1 = ∗ 100 = 9.1732%
0.0248 𝐾𝑊
0.0100 𝐾𝑊
𝜂2 = ∗ 100 = 34.2985%
0.0291 𝐾𝑊
0.0225 𝐾𝑊
𝜂3 = ∗ 100 = 57.6947%
0.0390 𝐾𝑊
0.0349 𝐾𝑊
𝜂4 = ∗ 100 = 74.6610%
0.0468 𝐾𝑊
0.0490 𝐾𝑊
𝜂5 = ∗ 100 = 84.3473%
0.0581 𝐾𝑊
0.0621 𝐾𝑊
𝜂6 = ∗ 100 = 105.5442%
0.0588 𝐾𝑊
GRÁFICAS
Q vs H
1.1400
1.1300
Q (m3/h) 1.1200
1.1100
1.1000
1.0900
1.0800
1.0700
0.0000 5.0000 10.0000 15.0000 20.0000 25.0000
H (m)
Q vs n
1.1400
1.1300
1.1200
Q (m3/h)
1.1100
1.1000
1.0900
1.0800
1.0700
0.0000 20.0000 40.0000 60.0000 80.0000 100.0000 120.0000
n (%)
ANALISIS DE RESULTADOS
Bomba centrífuga
En este equipo, experimentamos en base al gasto que se permitía suministrar al
sistema, que incrementaba con cada vuelta que se le daba a la válvula check
instalada después de la bomba. En base a esto hemos podido observar que con
cada vuelta el gasto ha incrementado de forma constante de aproximadamente 1
m3/h con cada vuelta.
Debido a lo anterior, la presión de succión de la bomba también ha aumentado de
forma constante. Por otra parte, también observamos que la altura manométrica del
sistema descendió conforme la presión de succión aumentaba, incluso hubo un
momento en el que la presión de succión fue mayor a la presión de descarga, lo
cual provocó alturas manométricas negativas.
La potencia hidráulica está varía según el gasto volumétrico y la altura manométrica,
de este modo obtenemos PH mayor a menor gasto y mayor altura manométrica. En
cuanto a la potencia al freno obtuvimos resultados basados en el torque, que es la
fuerza aplicada en una palanca que hace rotar alguna cosa. Al aplicar fuerza en el
extremo de una llave se aplica un torque que hace girar las tuercas, este lo
obtuvimos con la masa; así mientras la potencia al freno aumentaba, la potencia
hidráulica disminuía.
La eficiencia que se logro fue menor al 10% cuando el gasto volumétrico aumento.
En las gráficas observamos que cuando el gasto volumétrico aumenta la eficiencia
aumenta hasta un punto, la eficiencia es mayor, sin embargo, al rebasar un punto,
la eficiencia comienza a disminuir.