1. Objetivo General
2. Objetivos especficos
3. Datos
Flujo en paralelo
Temp. Entrada Agua Caliente T1= 36.73 C Temp. Entrada Agua Fra t1= 18.07 C
Temp. Salida Agua Caliente T2= 30.37 C (exp.) Temp. Salida Agua Fra t2= 32.77 C (exp.)
Caudal de agua Caliente Qc= 1.7 lt/min =0.102 m^3/hr = 2.833 E-5 m^3/seg
Caudal de agua fra Qf= 2.5 lt/min =0.15 m^3/hr = 4.167 E-5 m^3/seg
Flujo msico agua caliente W=114 Kg/hr Cp Agua caliente Cp= 1 Kcal/m hr C
Flujo msico agua fra w=90 Kg/hr Cp Agua Fra cp= 1 Kcal/m hr C
(1 1) (2 2)
= (4)()
(1 1)
(2 2)
(1 2) (2 1)
= (4)( )
(1 2)
(2 1)
1
Uo =
d
do Ln ( o )
1 di 1
+
hi di 2k ho
Fluido caliente
4
= (5)
2
2 1 0.14 3 0.14
= 0.116 [ 3 125] (Pr) 3 ( ) [1 + ( ) ] (6) ( ) =1
Fluido frio
0.14 0.14
( ) = 2.01 0.33 (7) ( ) =1
= (8)
= = = ( 2 2 ) (9)
4
= (10)
= (11)
+
1 1
= + (12)
2 = 1 + (2 )
2 = 1 (1 )
1 + 2 1 + 2
= (13) = (14)
2 2
Suponer T2
Calcular q con ecuacin 1
Calcular t2 con ecuacin 2
Calcular tm y Tm con ecuaciones 13 y 14
Leer de tablas o grficos , k, Pr
Calcular TLM ecua. 4 ( paralelo o contracorriente)
Calcular Re (fluido caliente y frio) con ecuaciones 5 y 9
Calcular hi con ecuacin 6
Calcular De con ecuacin 8
Calcular ho con ecuacin 7
Calcular hio con ecuacin 10
Calcular Uc con ecuacin 11
Calcular Uo con ecuacin 12
Calcular q con ecuacin 3
Calcular T2 con ecuacin 1
Si T2 es aproximadamente = T2 no
Fin
Paralelo Contracorriente
5. Resultados
Paralelo
T2(C q(Kcal/hr
) t2(C) ) TLM hi ho hio Uc Uo q' T'2
4.50E+0 1347.99 4.00E+0 3.37E+0 252.26 110.5 34.1
28 25.693 809.4 7.750 2 1 2 2 3 6 3
24.426 6.84E+0 1240.60 6.08E+0 4.41E+0 305.94 171.8 33.5
29 7 695.4 9.932 2 4 2 2 3 3 9
23.160 11.68 6.92E+0 1231.77 6.15E+0 4.43E+0 307.12 202.8 33.3
30 0 581.4 2 2 2 2 2 1 8 2
21.893 13.21 7.01E+0 1223.46 6.23E+0 4.46E+0 308.29 230.3 33.0
31 3 467.4 3 2 2 2 2 4 5 8
20.626 14.60 7.10E+0 1215.17 6.31E+0 4.48E+0 309.41 255.5 32.8
32 7 353.4 6 2 5 2 2 0 6 6
19.676 15.58 7.16E+0 1208.93 6.37E+0 4.50E+0 310.27 273.4 32.7
32.75 7 267.9 5 2 9 2 2 5 5 0
19.702 15.56 7.16E+0 1209.10 4.50E+0 272.9 32.7
32.73 0 270.18 0 2 2 636.678 2 310.25 9 1
Tm Re Pr k
31.55 2576.374 5.208 0.535 3.5212
32.05 3282.174 5.142 0.536 2.764
32.55 3315.763 5.085 0.5364 2.736
33.05 3348.811 5.032 0.5369 2.709
33.55 3381.893 4.979 0.5374 2.6825
33.925 3407.463 4.939 0.53788 2.66237
33.915 3406.785 4.94 0.537865 2.6629
tm Re Pr k
21.197 1180.196 6.765 0.5198 2.7952
20.563 921.991 6.888 0.519 3.578
19.930 907.533 7.014 0.518 3.635
19.297 893.280 7.132 0.5172 3.693
18.663 879.702 7.265 0.5163 3.75
18.188 869.660 7.359 0.5156 3.7933
18.201 869.913 7.357 0.51562 3.7922
Error Porcentual
T2(C q(Kcal/hr
) t2(C) ) TLM hi ho hio Uc Uo q' T'2
29.04 6.86E+0 1307.00 6.09E+0 4.50E+0 310.19 155.6
28 7 1003.2 8.875 2 4 2 2 8 8 35.43
27.78 10.02 6.98E+0 1297.94 6.21E+0 4.54E+0 312.27 177.0
29 0 889.2 4 2 7 2 2 9 2 35.25
26.51 11.16 7.07E+0 1289.29 6.29E+0 4.57E+0 313.50 198.0
30 3 775.2 9 2 2 2 2 1 0 35.06
25.24 12.31 7.16E+0 1280.54 6.36E+0 4.59E+0 314.69 219.0
31 6 661.2 0 2 1 2 2 7 7 34.88
23.98 13.45 7.25E+0 1271.93 6.44E+0 4.62E+0 315.90 240.2
32 0 547.2 0 2 6 2 2 6 7 34.69
22.71 14.58 7.38E+0 1263.47 6.56E+0 4.66E+0 317.76 262.1 34.50
33 3 433.2 7 2 2 2 2 1 2 1
21.44 15.72 7.41E+0 1227.02 4.62E+0 315.94 280.9 34.33
34 7 319.2 4 2 0 658.367 2 3 2 6
Tm Re Pr k
32.4 3305.735 5.01 0.5362 2.7443
32.9 3338.336 5.048 0.5368 2.7175
33.4 3371.712 4.995 0.5373 2.6906
33.9 3405.762 4.942 0.5378 2.6637
34.4 3440.507 4.889 0.5384 2.6368
34.9 3487.862 4.836 0.5389 2.601
35.4 3512.031 4.733 0.5395 2.5831
tm Re Pr k
23.473 1034.457 6.05 0.5264 3.189
22.840 1018.740 6.156 0.5254 3.2382
22.207 1003.493 6.262 0.5245 3.2874
21.573 988.696 6.368 0.5235 3.3366
20.940 974.329 6.747 0.5225 3.3858
20.307 960.374 6.58 0.5215 3.435
19.673 901.704 7.065 0.5171 3.6585