CURSO DE DIAMUX

Introducción al Entrenamiento de Access 300

Bienvenidos al entrenamiento de
Access 300

Diamux Training A/S


CURSO DE DIAMUX

ESTRUCTURA DEL E1

32 CANALES DE 64 KB/S

0                               1                             3
6 1

15 CANALES DE 64 KB/S 15 CANALES DE 64 KB/S

Diamux Training A/S


CURSO DE DIAMUX

ESTRUCTURA DEL PDH/SDH

MUX1
8 MB/S MUX1
34 MB/S MUX
E1/2 MB/S
E1/2 MB/S 8 MB/S 140 MB/S
E1/2 MB/S 8 MB/S
8 MB/S 34 MB/S
E1/2 MB/S
8 MB/S 34 MB/S STM-1
34 MB/S 155-3 MB/S

MUX2
34 MB/S
8 MB/S
8 MB/S
8 MB/S
8 MB/S
MUX4
8 MB/S
MUX3
E1/2 MB/S 34 MB/S
E1/2 MB/S
E1/2 MB/S 8 MB/S
E1/2 MB/S 8 MB/S
8 MB/S
8 MB/S

Diamux Training A/S


CURSO DE DIAMUX

Curso de Access 300:


- Conocer a la familia del Access 300
- Descripción del manual de documentación
- Descripción de las unidades o tarjetas
- Instalación física
- Conocer el AEM y el O&M
- Configurar el AEM
- Configuración del Diamux
- Conocer el sistema de gestión
- Diseño de la red vía NMAccess Engineering
- Operación y manejo de la red vía NMAccess Operator

Diamux Training A/S


CURSO DE DIAMUX
RED DE COMUNICACIONES: DIAMUX - PROMINA - SDH

JOSE
FURRIAL
SAN GERONIMO CERRO NEGRO

PALITAL

PUERTO MACAGUA
ORDAZ

EL CALLAO
LEYENDA

LAS CLARITAS
SDH

DIAMUX
STA ELENA
PROMINA

FIBRA OPTICA

ENLACE MICRO-ONDA

2 X 2MB

1 X 2MB

2 X 34MB

FIGURA 1 Diamux Training A/S


CURSO DE DIAMUX
ESQUEMA DE CONEXIÓN ENTRE LA S/E PALITAL – S/E FURRIAL
S/E PALITAL 400KV Y 115VV S/E FURRIAL 400KV Y 115 KV
DIAMUX 500
DIAMUX 500 PROMINA
PROMINA

6X2
ALT997 TMCP

SDH (AXD) 153-3 SDH (AXD) 153-3


ALT997 TMCP

ALT997 2X34 MBITS FIBRA OPTICA


TMCP
SERVICIOS EN LA S/E PALITAL

P21 2M
ALT997
TMCP

ALT997 TMCP

ALT997 TMCP
CONEXIÓN LATERAL
2 MBits DIAMUX-SDH
ALT999

DIAMUX 120

2MBit/s OPTICOS
A LA CAD 1 DE 400K ALT999

2MBit/s OPTICOS
A LA CAD 2 DE 400K ALT999

2MBit/s ELECTRICOS
A CERRO NEGRO
2MBit/s OPTICOS
A LA CAD 1 DE 115K ALT999

2MBit/s ELECTRICOS 2MBit/s OPTICOS


A PUERTO ORDAZ A LA CAD 2 DE 115K FIGURA 2
ALT999

Diamux Training A/S


CURSO DE DIAMUX
SHELF 4

COMMON SUBRACK

CONFIGURACION
XGM DIAMUX
PALITAL
SHELF 2

SHELF 1

Diamux Training A/S


CURSO DE DIAMUX

Access 300 products

Diamux 120
Diamux 120 in
Wall 6 cabinet

Diamux 20 II

Outdoor Cabinet Midi-3

Outdoor Cabinet Maxi-7


NTU 560

Diamux 120/500 Diamux 120/500


46 HU floor cabinet 21 HU wall cabinet GSP STM-1
Outdoor Cabinet Mini-1

Indoor Outdoor

Diamux Training A/S


CURSO DE DIAMUX

Presentation of the trainer

Diamux Training A/S


CURSO DE DIAMUX

Ericsson Diax Products


 Switching
– ANS TransLocal : SSP in Ericsson VPN-concept
– ANS Local : Full service switch for POTS, ISDN from
30 - 1400 subscribers
– ANS OPS : Operator service system, used as add on to AXE
local or as stand alone

 Access
– Diamux : Generic Access Nodes for POTS, ISDN, Data incl. V5
interfaces

 Management Systems
– AEM : Element Manager for Access Networks
– ANS Manager : ANS Management System
– NMAccess : Network Manager for Access- and Switching
Networks

Diamux Training A/S


CURSO DE DIAMUX

Presentation of the participants

Diamux Training A/S


CURSO DE DIAMUX

Practical information

Telephone

Toilets

Smoking

Diamux Training A/S


CURSO DE DIAMUX
Introduction to the Student Binder

Diamux Training A/S


CURSO DE DIAMUX

Product description

Diamux Training A/S


CURSO DE DIAMUX

Access 300 applications


POTS
Diamux 120 ISDN
Data
V5 POTS
ISDN
Data POTS
ISDN
RSC Diamux 20 II Data

POTS Analogue LL
ISDN
V5 Data Diamux NTU560 Data
Switch

HTU G.703

Diamux 120
+
SDH - Ring
GSP STM-1
(AXD 155-3A)
Analogue LL

AEM / NMAccess Diamux 500

Diamux Training A/S


CURSO DE DIAMUX

Access 300 POTS solution

V5.1 / V5.2 / RSM D5.1 / D5.2 (concentration)


AXE / POTS
Switch
Access 300 Access 300

STOP-Interface
D5.1 / D5.2 (concentration)
POTS
Switch
Access 300 Access 300

V5.1 / V5.2
POTS
Switch

Access 300

2 Mbit/s RSM / ESM


POTS
AXE

Access 300

Diamux Training A/S


CURSO DE DIAMUX

Access 300 ISDN solution

2B1Q
D5.1 / D5.2 (concentration)
ISDN
Switch

Access 300 Access 300

V5.1 / V5.2
ISDN
Switch

Access 300

Diamux Training A/S


CURSO DE DIAMUX

IP ‘always on’ using single-pair HDSL

IAS (TIGRIS AXC623)


LAN
IP 10 Base-T
PPP
N x E1

Single pair HT116


HDSL

PSTN ALT620

Diamux

Diamux Training A/S


CURSO DE DIAMUX

End user products for data leased lines


IAS 1 pair
HDSL HT111
IP ALT620 G.703
1 pair
HDSL HT114 V.35
N x E1 ALT620 V.36
X.21
1 pair
HDSL HT116
ALT620 LAN 10BaseT
Bridging
Draytek Vigor2000
IGM441 ISDN
6xLAN
NTU560
IGM441 V.36,V35,X.21
V.35
ZyXEL Prestige V.36
Diamux 500 HD SDU950
X.21
Diamux 120 HD V.35/ LAN/WAN routing
SDU950 V.36 HT114 HT116
LAN 10BaseT
Bridging
Diamux Training A/S
CURSO DE DIAMUX

LAN access
AEM / NMAccess

1 pair PSTN
HDSL

Ethernet HT116 HT114 ISDN


V.35/V.36

S
D
U
Data
2 pair H H
G.703 1 pair HDSL
D D
S S Diamux 500
V.35 HDSL
L L
HT111 ALT620
V.36 H
D
H
D
X.21 S
L
S
L
1 pair “Back to back” ALT620
ALT495
HDSL
ALT620
H
Diamux 120 ALT620 D POTS
ALT495 S
L ISDN
1 pair
H
HDSL D Data
HDSL Features Ethernet HT116 S
L
 Repeater possibility
 n x 64 kbit/s services Diamux 120

Diamux Training A/S


CURSO DE DIAMUX

The Access 300 system series

Diamux 120
Diamux 20 II

Diamux NTU560

Diamux 120II

Diamux 500 Diamux 500 HD

Diamux Training A/S


CURSO DE DIAMUX

Diamux 500
Capacity:
 POTS subscribers only: (New PSB)
– 1320 (V5.2) with 4 x 2 Mbit/s aggregate termination
– 720 (V5.1/ESM) with 24 x 2 Mbit/s aggregate termination

– 1380 (V5.2) with 8 x 2 Mbit/s aggregate termination


– 1140 (V5.1/ESM) with 38 x 2 Mbit/s aggregate termination

 ISDN subscribers only: (New PSB)


– 616 (V5.2) with 4 x 2 Mbit/s aggregate termination
– 336 (V5.1) with 23 x 2 Mbit/s aggregate termination

– 672 (V5.2) with 12 x 2 Mbit/s aggregate termination


– 616 (V5.1) with 44 x 2 Mbit/s aggregate termination

– Data only: (New PSB)


– 88 x 2 Mbit/s opto or G.703
– 336/616 connected Diamux NTA10
– 720/1140 analogue leased lines
– 720/1140 G.703 co-directional 64 Kbit/s

Diamux Training A/S


CURSO DE DIAMUX

Diamux 500, continued

 Transmission:
– Copper, Fibre

 Installation:
– 2 - 9 subracks
– 19” rack (RACK-46)
– Outdoor Cabinet (MAXI-7, BYB)

 Power:
– -48V, 1150W (consumption)
– 220V, 50 Hz (optional)

Diamux Training A/S


CURSO DE DIAMUX

GSP Architecture
GSP Common Section Subrack
 Hardware for core and control part
 System / Application software
1  DC/DC power
 Connection to management
 SLMS interface (optional)
 EMC approved on subrack level

GSP Interface Subrack


 Hosting interface units
 All services in one subrack
 DLL of interface protocols
1-8
 DC/DC power
 DRG (ringing generator)
 Full cabled: 26 x 2 Mbit/s
 Partial cabled: 180 POTS
 SLMS interface (optional)

Diamux Training A/S


CURSO DE DIAMUX

Diamux 120
Capacity:
 POTS subscribers only:
– 142 (V5.2) with 1 x 2 Mbit/s aggregate termination
or
– 120 (V5.1) with 4 x 2 Mbit/s aggregate termination

 ISDN subscribers only:


– 70 (V5.2) with 1 x 2 Mbit/s aggregate termination
or
– 70 (V5.1) with 5 x 2 Mbit/s aggregate termination

 Data only:
– 14 x 2 Mbit/s optical or electrical
– 70 connected NTU560 (“Connected to ISDN
cards”)
– 120 analogue leased lines
– 120 G.703 co-directional 64 Kbit/s

Diamux Training A/S


CURSO DE DIAMUX

Diamux 120, continued

 Transmission:
– Copper, Fibre

 Installation:
– 1 subrack
– 19” rack, indoor
– Outdoor Cabinet
 Power:
– - 48V, 140W (consumption)
– 220V, 50 Hz (optional)

Diamux Training A/S


CURSO DE DIAMUX

Diamux 20 II
Capacity:
 POTS subscribers only:
– 14 POTS (24 UK/US due to special card),
1 x 2 Mbit/s aggregate termination
 ISDN subscribers only:
– 15 ISDN BRA subscribers,
1 x 2 Mbit/s aggregate termination
 Data only:
– 7 x (n x 64) Kbit/s V.11
– 28 x 2w/4w analogue leased line
 Digital cross-connect; DXC I/0
– 8 x 2 Mbit/s
 Transmission:
– Copper, Fibre
– Installation:
– 19” rack, wall or desktop
 Power:
– 230/120V, 50-60 Hz, 80-100W (consumption)

Diamux Training A/S


CURSO DE DIAMUX

Diamux NTU 560


Features:
 NTU with ISDN U-interface

 Data rates:
– Asynchronous data rates between
1200 bit/s and 38.4 Kbit/s
– Synchronous data rates between
1200 bit/s and 128 Kbit/s

 Transmission:
– Connection with normal copper-pair

 interface units:
– V.24/V.28, V.11/V.36, V35 and X.21
using adapter cables for fitting.

 Power:
– 12 V AC,500 mA, 50/60 Hz

Diamux Training A/S


CURSO DE DIAMUX

STM-1 (SDH)

DC/DC, ringer etc.


Common part
Diamux

Pair Gain
Pair Gain
Pair Gain
POTS
POTS

POTS

POTS
POTS
POTS

HDSL
HDSL
HDSL
DATA
ADSL
ADSL
Shelf

ISDN
ISDN
ISDN
E1
E1

GSP STM-1
Shelf

 Space optimised solution


– only 2 HU (88,9 mm) high with built-in airguide

 For 19” Installation

Diamux Training A/S


CURSO DE DIAMUX

Installation

 Tools:
– No special tools are needed (screwdriver)

 Installation time (from unpacking until system is operational):


– 1 day for large Diamux 500, Installation and configuration
– 2 hours for Diamux 120, Installation and configuration
– Assumptions:
External cabling available and System data prepared in multi-command files.

 Connections to subscriber lines:


– Cables are wire wrapped on termination panels
– Pre-wired termination panels are available

Diamux Training A/S


CURSO DE DIAMUX

The Access 300 system series


Sub. data
A P
C A
T S
I S
Program V I
A P E V
C A E
T S
I S
V I
E V Swap
E Changes
Access 300
 Hot insertion
 Unit change without interrupt New SW
 Reconfiguration without interrupt
 SW modification without interrupt
 Subscriber data change without interrupt

Diamux Training A/S


CURSO DE DIAMUX

The Access 300 system series


DMX500 DMX500 HD DMX120 DMX120 HD DMX20 II

PSTN 1380 sub 1380 sub 142 sub 315 sub 14 sub
(8 E1s) V52 (8 E1s) V52 (1 E1) V52 (1 E1) V52 (1 E1)

1080 sub 1080 sub 120 sub 210 sub 24 sub


(36 E1s) V51 (36 E1s) V51 (4 E1s) V51 (7 E1s) V51 (1 E1) for UK/US

ISDN 630 sub 644 sub 70 sub 132 sub 15 sub


(12 E1s) V52 (8 E1s) V52 (1 E1) V52 (1 E1) V52 (1 E1)

476 sub 504 sub 70 sub 98 sub


(34 E1s) V51 (36 E1s) V51 (5 E1s) V51 (7 E1s) V51

DATA 88 E1s or 88 E1s or 14 E1s or 14 E1s or 7 * n*64kbit/s or


1080 * 64 kbit/s 1080 * 64 kbit/s 120 * 64 kbit/s 210 * 64 kbit/s 8 * 2 Mbit/s

Diamux Training A/S


CURSO DE DIAMUX

Supplied housing for Access 300 products

Diamux 120
Diamux 120 in
Wall 6 cabinet

Diamux 20 II

Outdoor Cabinet Midi-3

Outdoor Cabinet Maxi-7


NTU 560

Diamux 120/500 Diamux 120/500


46 HU floor cabinet 21 HU wall cabinet GSP STM-1
Outdoor Cabinet Mini-1

Indoor Outdoor

Diamux Training A/S


CURSO DE DIAMUX

Power and battery back-up

NTU 560

Battery
back-up Diamux 20 II Converter Unit
Control Unit

Diamux 500 and Diamux 120

Diamux 120 in Wall 6


Diamux Training A/S
CURSO DE DIAMUX

Power
EX. : AC/DC Basic System 600w
• AC/DC Basic System 300w - 1800w
Up to 900w in one subrack

• Battery backup 13,5Ah - 96Ah


With chargecontroller

• Connection to AMU for supervision

Diamux Training A/S


CURSO DE DIAMUX

OMII, AEM and NMAccess


NMAccess
NMAccess Server

NMAccess Clients
- Network Engineering
- Network Operation
- ……..

AEM
OMII software
+
Access 300 Database

OM II
OMII Server

OMII Clients
- Configuration Management
- Fault Management
- Security Management

Diamux Training A/S


CURSO DE DIAMUX

Management system architecture

Clients LAN Servers


(Workstations) Access 300
OM II server

AEM Client

NMAccess
server(s)
NMAccess
Client

Database
server
AEM Client

Windows NT
 Client / server based distributed
Domain server computer environment
SQL  SQL database
 Scaleable

Diamux Training A/S


CURSO DE DIAMUX

NMAccess - Network Engineering.

Diamux Training A/S


CURSO DE DIAMUX

NMAccess - Network Operation

Diamux Training A/S


CURSO DE DIAMUX

Standard Documentation

Standard Documentation to Access300


• How to view the Documentation
• The media
• The Document Structure

Standard
Documentation

Diamux Training A/S


CURSO DE DIAMUX

Product documentation menu page

Step 1
Step 2

x.yz

Step 3
Diamux Training A/S
CURSO DE DIAMUX

Important binders

Binder title Contents


Technical handbook Information about how to install different network elements

Operator’s guide Information about how to maintain the system

Command Ref. guide Command descriptions of all commands

Product configuration List information on software and hardware in a specific


product release

Diamux Training A/S


CURSO DE DIAMUX
AEM Links &
1 DB (Access Element Manager) Routes

Network Database OM-MTP

Sheet to fill with Hardware Units


VED
2 ID OM Sync
Vital Element Data
3 DLL

Links &
4 CCS7 ALT
Routes MTP

Synchronisation
Interface Definition

Date &
Hardware
6

7
Alarm Subscription
OM-1 OM-2
Time
Alarm Data
Units
Access Table
8 OM-1 OM-2 OM Access

9 Power Part no.1


Subscribers
10 Dump

11 STM-1

12 NMAccess Engineering

Installation
13

Diamux Training A/S


CURSO DE DIAMUX

Hardware unit label

Serial number Version


barcode A
Unit name
8008442A

Part list
8008442A
R1 R1
G01424050A IGMS-442
G01 97W05
Nick name
IGMS-442

Serial number
G01424050A Production site Production week
G01 97W05

Diamux Training A/S


CURSO DE DIAMUX

Approved hardware
Number The number and version of the hardware unit

Mod. The modification number and eventual Rev. letter.


(Mod is an obsolete indication for old production batches)

SWP If the unit requires a SW package this is indicated by a *

CE (EMC) The Object has been evaluated against applicable directives mentioned in the
DCT (declaration of conformity) document.
 = Approved. Units are allowed in CE marked systems.
N/A = Not applicable. Units are allowed in CE marked systems.
= Units without a mark are not allowed in a CE marked system.

Density HD = Can only be used in high density systems.


SD = Can only be used in standard density systems
= Units without mark can be used in both high and standard density systems.

Name The unit name, the abbreviation for the unit and explanatory text.

Diamux Training A/S


CURSO DE DIAMUX
Hardware units used in DSU 568
Data service unit
LAU001
Local area unit
PSU097
Power supply unit

Diamux 500 systems


Central processor unit. Holds the working signaling to the management Converts incoming DC to 5 V/12 V
program, element data and back-up files. system and / or other switches used for all units.
through LAN. Protocol is TCP/IP

PSB
Packet switch block PSU098
Handles internal packet Power supply unit
switching in the GSP. Converts incoming DC to line
feeding voltage, ringing voltage and
private metering pulses.
CSB Level 4
Circuit switch block Level 3 PSU099
Data Channel Power supply unit
Non-blocking digital switch.
Capacity is 88 2 Mbit/s PCM. Service Block Converts incoming DC to voltages
Level 2 DSU needed in a HD sub-rack.

AGM Level 1
Analog group module PSB CTU
Terminates POTS subscriber lines. Clock and tone unit
30 POTS in a group CCS7 Generates internal clock for GSP.
Generates tones for subscribers.
Subscriber line LAU
IGM termination block PSU
ISDN group module PSU LAN IHU (DSU 560)
IGM CSB AMU
Terminates basic rate subscriber Basic access CTU
Interface handling unit
ALT Handles the XGM sub-racks.
lines. 14 BRA in a group (ISDN 2) AGM IHU
SHU
ALT Data channel
ALT termination block
Autonomous line terminating unit ALT Miscellaneous SHU (DSU 560)
Terminates 2 Mbit/s PCM systems. System handling unit
Primary Analog
ALT
HW-driver via ABUS. Contains Vital
Various protocols available, e.g.
CCS7, R2, CAS. rate access (POTS)
ALT V.24 To AEM / NMAccess Element Data. Interfaces Diamux to
(ISDN 30) SDU AEM at 9.6 kbit/s.

SDU Access 300


Synchronous data unit PCM Lines AMU
Dual data interface unit for Termination Analog measurement unit
V.36/V.11 and X.24/X.27 (X.21 block Measures subscriber line data.
leased line version). Codec test. Generates test tone.

Diamux Training A/S


CURSO DE DIAMUX

SHU - System handling unit


The SHU HW platform is the processor unit DSU 560
Level 4
Level 3 EPROM Memory RAM Memory
Level 2 DSU

Level 1
SHU/IHU4
PSB 32kbyte
CCS7

PSU
LAU SHU/IHU3 8 kbyte
PSU
IGM
ALT
CSB CTU
AMU 32kbyte RAM
AGM IHU
SHU
IHU
ALT

ALT Miscellaneous
SHU/IHU2
ALT
ALT
To AEM / NMAccess
V.24
32kbyte
SDU 2 kbyte
SHU/IHU1 RAM with
32kbyte battery backup

VED
Exchange type Battery lifetime,
Point code production date
Signaling plus 10 years
Synchronization
Diamux Training A/S
CURSO DE DIAMUX

IHU - Interface handling unit


Level 4 The IHU HW platform is the processor unit DSU 560
Level 3

Level 2 DSU
EPROM memory RAM memory
Level 1
PSB
SHU/IHU4
CCS7 32kbyte
LAU

IGM CSB
PSU
PSU
AMU
SHU/IHU3 8 kbyte
ALT
AGM
SHU
IHU
IHU
CTU
32kbyte RAM
ALT

ALT
ALT
Miscellaneous SHU/IHU2
ALT
SDU
32kbyte
2 kbyte
SHU/IHU1 RAM with
32kbyte battery backup

Not used for VED

IHU 1 to 4
XGM HD XGM
Diamux Training A/S
CURSO DE DIAMUX

DSU - Data service unit


Level 4
Level 3 The DSU HW platform is the unit DSU 568
Level 2 DSU
The main processor is an
Level 1
DSU
AMD 29030 RISC processor
PSB
CCS7

LAU
PSU Miscellaneous
PSU
IGM CSB AMU
ALT CTU
AGM IHU
SHU
IHU
ALT
Basic 1 Mbyte
ALT
ALT Initial program EPROM
ALT
Application 16 MByte
SDU
Active Passive
program FPROM
Program Program
No redundancy Redundancy 2 Mbyte
Command Local Dump SRAM
Application Log Area
Data with back-up
Element Data 6.5 Mbyte
Working SRAM
Data Stack/Heap (Process Data)

Diamux Training A/S


CURSO DE DIAMUX

CSB - Circuit switch block The DSU HW platform is the unit CSB 080
Level 4
Level 3 Memory table
Level 2 DSU

Level 1
708 Address 740
PSB
CCS7
Memory
LAU

IGM CSB
PSU
PSU
AMU
708 Data (Speech) 96 · 32
ALT CTU
AGM
ALT
SHU
IHU
IHU byte
ALT
ALT
ALT Miscellaneous
SDU

AGMM UAD 408

TS 4
SYS-RDCSB:MUX,704;
AGMM UAD 404 this command will read out all
connections related to UAD 404
TS 4
Diamux Training A/S
CURSO DE DIAMUX

PSB - Packet switch block


Level 4
Level 3 The PSB HW platform is the unit PSB128
Level 2 DSU

Level 1
PSB
CCS7

LAU
PSU
PSU
IGM
ALT
CSB
IHU
CTU
AMU
1 PCM = 16 PSB channels
AGM
ALT
SHU
IHU
1 PSB channel = 2 · 64 kbit/s
ALT Miscellaneous
ALT
ALT
SDU

from/to PSB from/to


layer 2 128
layer 4

There are 94 PSB channels available for interface units.


The available PSB channels for XGM units are limited to 46.

Diamux Training A/S


CURSO DE DIAMUX

CTU - Clock and tone unit


Level 4
Level 3 The CTU HW platform is the unit CTU 935
Level 2 DSU

Level 1
PSB
CCS7 Sync. from 8 internal
PSU
LAU 8 kHz. reference
PSU
IGM CSB AMU
ALT CTU
AGM
ALT
SHU
IHU
IHU Sync. from 1 external
2,048 MHz reference
ALT Miscellaneous
ALT
ALT
SDU Configurable tones
UAD 200 -203 CTU

Diamux Training A/S


CURSO DE DIAMUX

AMU - Analogue measurement unit


Level 4 The AMU HW platform is the unit AMU 995
Level 3
AMU 995
Level 2 DSU

Level 1
PSB Line measurements
CCS7
Volt, Capacities and Resistance
LAU

IGM CSB AMU


PSU
PSU AGMx
ALT
AGM IHU
CTU
IGMx
ALT
SHU
IHU
CODEC test
ALT Miscellaneous
ALT
ALT
SDU

[Volt]
10 high 12 digital
5 analogue
input NT
input low
0 Time Sound
1 analogue 3 relay Alarm light
-100 input output ISDN
Fan units in cabinet

Diamux Training A/S


CURSO DE DIAMUX

LAU - Local area unit The LAU HW platform is the unit LAU 001
Level 4
Level 3

Level 2 DSU

Level 1
PSB
CCS7

LAU
PSU
PSU
IGM CSB AMU
ALT CTU
AGM IHU
SHU
IHU
ALT

ALT Miscellaneous
ALT
ALT
SDU

signaling to the management system


through LAN. Protocol is TCP/IP
Speed 64 kbit/s or 100 kbit/s - 200 kbit/s

Diamux Training A/S


CURSO DE DIAMUX

AGM - Analogue group module


The following units can be used as HW platform
For HD systems For SD systems
AGM 415 AGMM 460/AGMS 461
1 group = 2 units 1 group = 1 Master + 3 Slaves
1 group = 30 subscribers 1 group = 30 subscribers
15 subscribers on each unit 6 subscribers on master unit
8 subscribers on slave unit
Level 4
Level 3

Level 2 DSU • Line current limitation


Level 1
PSB
and overvoltage protection
CCS7
• Programmable line impedance's
LAU
PSU
PSU
IGM
ALT
CSB CTU
AMU • CODEC function
AGM IHU
SHU
IHU
ALT
• ON/OFF hook detection
ALT Miscellaneous
ALT
ALT • Interface to coin boxes
SDU

• Metering pulses (12 or 16 kHz)

Diamux Training A/S


CURSO DE DIAMUX

AGM - Analogue group module The hardware platform is AGM 940/941


Level 4
Level 3

Level 2 DSU
• Termination for PSTN subscribers
Level 1 outgoing from a telephone exchange
PSB
CCS7 • Each subscriber termination has the
PSU
PSU
LAU same functionality as an ordinary PSTN
IGM
ALT
CSB CTU
AMU
telephone
AGM IHU
SHU
IHU
ALT
• Optional line impedance. 5 different
ALT Miscellaneous
ALT values
ALT
SDU

AGMM940/AGMS941
Any switch
Standard density High density
1 group = 1 Master + 3 Slaves 1 group = 1 Master + 1 Slave
1 group = 30 subscribers 1 group = 14 subscribers
6 subscribers on master unit
8 subscribers on slave unit
Diamux Training A/S
CURSO DE DIAMUX

AGM - Analogue group module The hardware platform is AGM 790/791


Level 4
Level 3

Level 2 DSU • Termination for analog leased lines 2-


Level 1
PSB
wire or 4-wire
CCS7
• Adjustable gain setting (Rx/Tx level)
LAU
PSU
PSU
IGM CSB AMU
ALT CTU
AGM IHU
SHU
IHU
ALT

ALT Miscellaneous
ALT
ALT
SDU

AGMM790/AGMS791
Standard density High density
Analog leased 1 group = 1 Master + 3 Slaves 1 group = 1 Master + 1 Slave
line equipment 1 group = 30 subscribers 1 group = 14 subscribers
6 subscribers on master unit
8 subscribers on slave unit
Diamux Training A/S
CURSO DE DIAMUX

SDU - Synchronous data unit


Level 4
Level 3
The SDU HW platform is the unit SDU 950
Level 2 DSU

Level 1
PSB
CCS7

LAU
PSU
PSU
IGM CSB AMU
ALT CTU
AGM IHU
SHU
IHU
ALT

ALT Miscellaneous
ALT
ALT
SDU

V.36/V.11
Digital leased line or
equipment X.24/X.27 (X.21 leased line version)

Diamux Training A/S


CURSO DE DIAMUX

IGM - ISDN group module The IGM HW platform is the unit, IGMM 441/IGMS 442
Level 4
Level 3

Level 2 DSU A basic rate subscriber has 2 B


Level 1 channels and 1 D channel
PSB
CCS7
B channel = 64 kbit/s
PSU
PSU
LAU
D channel = 16 kbit/s
IGM CSB AMU
ALT CTU
AGM IHU
SHU
IHU
ALT
+/- 5 volt
ALT
ALT
Miscellaneous
12 volt
ALT
SDU
- 84 volt
NT
IGM441/442 units -97 volt
Termination for ISDN subscribers for power feeding
Any switch outgoing from a telephone exchange
1 group = 1 Master and 1 Slave
1 group = 14 subscribers
6 subscribers on master unit
8 subscribers on slave unit
Diamux Training A/S
CURSO DE DIAMUX

ALT - Autonomous line termination unit


Level 4
Level 3

Level 2
The following units can be used as HW platform
DSU

Level 1
PSB ALT 949 2 Mbit/s
CCS7
75 ohm balance / unbalance cable
LAU
PSU
PSU
AMU
120 ohm balance cable
IGM CSB CTU
ALT
AGM IHU
SHU
IHU
ALT
ALT 999 2 Mbit/s optical unit
ALT Miscellaneous
ALT
ALT
SDU

ALT 202 / ALT 204 8 Mbit/s optical master unit


ALT 949 / ALT 202 are used as slave units

ALT 400 4 · 2 Mbit/s high capacity unit (E1)

ALT 620 2 Mbit/s, using subscriber cable

ALT xxx - ALT xxx ALT 669 1.5 Mbit/s T1


Diamux Training A/S
CURSO DE DIAMUX

PSU - Power supply unit The following units can be used as HW platform
Level 4
Level 3
PSU 097
Level 2 DSU
Input: -41 to -70 Volt
Level 1
PSB Output: +/- 5 Volt
CCS7 + 12 Volt
LAU
PSU
PSU
IGM CSB AMU
ALT CTU
AGM IHU
SHU
IHU
ALT
PSU 098
Miscellaneous
ALT
ALT Input: -41 to -70 Volt
ALT
SDU Output: -63 / -68 Volt
-84 Volt
-97 Volt
PSU 099 70-105 Volt AC (20/25/50 Hz)
INPUT: -41 to -70 volt
OUTPUT: +/- 5 volt
+ 12 volt
-63/-68 volt
-84 volt
-97 volt70-105 volt AC (20/25/50 Hz)
Diamux Training A/S
CURSO DE DIAMUX
PSU097

Hardware units used in Diamux 120 systems Power supply unit


Converts incoming DC to 5 V/12 V
used for all units.

PSU098
Power supply unit
Converts incoming DC to line
feeding voltage, ringing voltage and
private metering pulses.
DSU 568 / 576 Level 4
Data service unit PSU099
Central processor unit. Holds the working Level 3 Data channel Power supply unit
program, element data and back-up files. service block Converts incoming DC to all
Level 2 DSU voltages needed in a HD sub-
rack.
AGM Level 1
Analog group module “PSB” MSU (DSU 983)
Terminates POTS subscriber lines. Main system unit
30 POTS in a group CCS7 HW-driver via ABUS. Contains vital
element data. Interfaces to AEM at
Subscriber line LAU
9.6 kbit/s. CSB, PSB and CTU
IGM termination block PSU functionality.
ISDN group module PSU LAN
IGM “CSB” AMU
Terminates basic rate subscriber Basic access “CTU”
ALT
MSU AMU
lines. 14 BRA in a group (ISDN 2) AGM Analog measurement unit
ALT Data channel Measures subscriber line data.
Codec test. Generates test tone.
ALT termination block
Autonomous line terminating unit ALT Miscellaneous
Terminates 2 Mbit/s PCM systems. Primary ALT
Various protocols available, e.g. Analog LAU001
CCS7, R2, CAS. rate access (POTS)
ALT V.24 To AEM / NMAccess Local area until
(ISDN 30) SDU signaling to the management
system and / or other switches
SDU Access 300 through LAN. Protocol is TCP/IP
Synchronous data unit PCM Lines
Dual data interface unit for V.36 / Termination
V.11 and X.24 / X.27 (X.21 leased block
line version).

Diamux Training A/S


CURSO DE DIAMUX

MSU - Main system unit


The MSU HW platform is the processor unit DSU 983
Level 4
Level 3

Level 2 DSU

Level 1
PSB
CCS7

IGM CSB PSU


ALT AMU
AGM MSU
ALT

ALT
ALT
LAU
SDU

• Local connection to O&M system


• Controls the system in test mode
• Holds non-voluntary memory containing the vital element data (VED)
• Holds CTU,CSB and PSB functionality

Diamux Training A/S


CURSO DE DIAMUX

DSU - Data service unit The DSU HW platform is the unit DSU 576
Level 4 The main processor is an
Level 3
AMD 29030 RISC processor
Level 2 DSU
DSU
Level 1
PSB
CCS7

LAU
PSU Miscellaneous
PSU
IGM CSB AMU
ALT CTU
AGM IHU
SHU
IHU
ALT
Basic 1 Mbyte
ALT
ALT Initial program EPROM
ALT
Application 8 MByte
SDU
Active Passive
program FPROM
Program Program
No redundancy Redundancy 0.5 Mbyte
Command Local Dump SRAM
Application Log Area
Data with back-up
Element Data 1.5 Mbyte
Working SRAM
Data Stack/Heap (Process Data)

Diamux Training A/S


CURSO DE DIAMUX
AEM Links &
1 DB (Access Element Manager) Routes

Network Database OM-MTP


Installation of Diamux equipment
VED •Hardware Units in Common Section
2 ID OM Sync
Vital Element Data •Mounting Hardware Unit

3 DLL •Services Supplied


•Strapping of Hardware Units
Links &
4 CCS7 ALT
Routes MTP

5 Interface Definition

Synchronisation Date &


Mounting
6
Alarm Subscription
Time of
7 OM-1 OM-2

Access Table
Alarm Data
Hardware Units
8 OM-1 OM-2 OM Access

9 Power
Subscribers
10 Dump

11 STM-1

12 NMAccess Engineering

Installation
13

Diamux Training A/S


CURSO DE DIAMUX

Mounting units
Subrack position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
S I I I I D D C C P P C C L A Power Power
H H H H H S S S S S S T T A M
U U U U U U U B B B B U U U U
1 2 3 4 5 5 0 9
6 6 B B B 0 9
GSP 8 8 1 5

00H 01H 02H 03H 04H 06H 07H 08H 09H 0AH 0BH 0CH 0DH 0EH 0FH 10H 11H 12H 13H 14H 15H 16H 17H 18H
UAD
05H
Control Section Core Section

Subrack position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
M D D A M S S S M S S S M S S S M S S S M S 4
S S Power Power
S S S M
U U U U L
MiniGSP 5
7
5
7
9 A
9 U
and HD 6 6 5 0 or or
0 Ring. Ring.
MiniGSP 1 gen. gen.

00H 01H 03H 04H 05H 06H 07H 08H 09H 0AH 0BH 0CH 0D 0EH 0FH 10 11H 12H 13H 14H 15H 16H 17H 18H 19H
UAD H H

Common Interface Section Power


Section (Shaded positions have PSB/PCM access) Section
02H

= Mandatory Hardware Unit


Diamux Training A/S
CURSO DE DIAMUX

Mounting Cards
Subrack position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
S I I I I C D C C C C C C C C C C P P C C L A Power Power
H H H H H C S C C C C C C C C S S S S T T A M
U U U U U S U S S S S S S S S B B B B U U U U
1 2 3 4 7 5 7 7 7 7 7 7 7 7 0 9
6 B B B 0 9
8 1 5
GSP

00 H 01 H 02H 03H 04H 05H 0 6H 07H 08H 09H 0AH 0BH 0CH 0DH 0EH 0FH 1 0H 11H 12H 13H 14H 15H 16 H 17H 18H
UAD
Control Section Core Section

Subrack position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
M D P A M S S S M S S S M S S S M S S S M S 4
S S Power Power
S S S M
U U B U L
MiniGSP 5
7
1 9
9 9
A
U
or
and HD 6 8 5 0
0
or
Ring. Ring.
MiniGSP 1 gen. gen.

00H 01H 02H 03H 04H 05H 06H 07H 08H 09H 0AH 0BH 0CH 0DH 0EH 0FH 10 11H 12H 13H 14H 15H 16H 17H 18H 19H
UAD H

Common Interface Section Power


Section (Shaded positions have PSB/PCM access) Section

= Mandatory Hardware Unit Only if DSU982 is used as MSU. Not available in HD MiniGSP

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in “Common Section”, Only


Diamux500 Diamux120 Diamux120II Diamux20II
Processor DSU DSU DSU DSU

560, 568 982, 983, 576 983, 576 642


Internal Switch Various types PSB -- DSU

CSB080, PSB037, 198 (only together none 642


PSB128 with DSU982)
Clock CTU DSU DSU DSU
035, 935 982, 983 983 642
Measurement AMU AMU AMU --
995 995 995 none
Signaling Various types Various types Various types --
CCS7038 CCS7038 CCS7038 none
Power Various types Various types Various types Various types
PSU097, PSU098, PSU097, PSU098, PSU099 PSU701, PSU702,
DC/DC 784, DRG 783 DC/DC 784, DRG 783 BBU731
Local Area LAU LAU LAU None
Network
001 001 001 ..

Diamux Training A/S


CURSO DE DIAMUX

Main Units in GSP / MiniGSP / HD MiniGSP


Function Type of card Position Mandatory for CS
GSP
SHU (System Handling Unit) DSU560 H’00 Yes
IHU (Interface Handling Unit) DSU560 H’01 - H’04 No
Main Processor Board DSU568 H’06 Yes
System 7 signalling CCS7 H’05 + H’07 - H’0E No
Circuit Switch Block CSB080 H’0F Yes
Packet Switch Block PSB037/128 H’11 Yes
Clock and Tone Unit CTU035/935 H’13 Yes
Local Network Unit LAU001 H’15 No
Analog Measurement Unit AMU995 H’16 No

Power Supply PSU097 H’17 - H’18 Yes


Power Supply DC/DC 784 H’17 - H’18 Yes

MiniGSP Function Type of card Position Mandatory for CS


MSU (Main System Unit) DSU982/983 H’00 Yes
or
Main Processor Board DSU576 H’01 Yes
HD Packet Switch Block PSB198 H’02 Yes/ No (if DSU983 used)
MiniGSP “System 7 signalling” “CCS7” “H’02” No
Analog Measurement Unit AMU995 H’03 No

Power Supply PSU098 H’016, H’18 Yes / No


Digital Ringing Generator DRG 783 H’016, H’18 Yes / No
Power Supply PSU097 H’16 - H’19 Yes
Power Supply DC/DC 784 H’16 - H’19 Yes

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in Common Section of Diamux 500, Only

 DSU560 (Data Service Unit)


– Multi purpose microcontroller unit.
– Battery back-up of the RAM chip.
– SHU: (System Handling Unit)
– Local Connection to O&M System.
– Controls the system in Test Mode.
– Main role in the restart procedure.
– Holds non-voluntary memory containing the Vital Element Data (VED).
– Controls Alarm Flow.
– IHU: (Interface handling Unit)
– Handling capacity: 1 or 2 interface Subracks (XGM).

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in Common Section of Diamux 500, Only

 DSU568 (Data Service Unit)


– Controls the system in Operation Mode.
– Holds the Application Software of the system.
One Active and one Passive copy.
(Active and Passive can be different Releases)
– Executes the Application Software of the System.
– Holds: Command Log, Local Dump and Element Data.

Initial EPROM
Basic
Program
Application Active Passive FPROM
Program Program Program
RAM
CommandLog Local Dump Area with back-up
Application
Data
Element Data
RAM
Working
Data Stack/Heap (Process Data)

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in Common Section for Diamux 500, Only


 CSB 080 (Circuit Switch Block)
– Switching capacity upto 87 internal 2 Mbit/s ports.

 PSB 037 (Packet Switch Block)


– Switching of upto 48 channels for internal signalling between the Application Software on the
DSU568 Unit and the Interface Units.
Used for AGM- , IGM- , CGM- , ALT- (running Protocol) , AMU- , and CSU hardware units.

 PSB 128 (Packet Switch Block)


– Same function as PSB037, but the switching capacity is up to 88 channels for internal
signalling between the Application Software on the DSU568 Unit and the Interface Units.

 CTU 035 (Clock and Tone Unit)


– Generate and supply the internal clock and synchronisation to the system.
– Generates 4 tones.
– Used by the Diamux: Idle- and Congestion-tone.
– Not used by the Diamux: Dial- and Announcement tone.
– Can be synchronised from incoming PCM connected to the XGM Subrack address
H’200..H’203.
– Must NOT be REMOVED when SHU is inserted. This will damage Vital Element Data (VED).

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in Common Section for Diamux 500, Only


 CTU 935 (Clock and Tone Unit)
– Generate and supply the internal clock and synchronisation to the system.
– Generates 4 tones.
– Used by the Diamux: Idle- and Congestion-tone.
– Not used by the Diamux: Dial- and Announcement tone.
– Can be synchronised from incoming PCM connected to the XGM Subrack address
H’200..H’203.
– Can synchronise on input from a G.703 §10 source.
– Possibility of self configuration of tones by commands..
– Must NOT be REMOVED when SHU is inserted. This will damage Vital Element Data (VED).

 CCS7 038 (Common Channel Signalling No. 7)


– Terminates CCiTT system7 signalling.
– Works in symbioses with: ALT997, ALT949, ALT999, ALT668, ALT 495, IGM, CGM and SDU.

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in Common Section of Diamux 120 and


Diamux 120II, Only

 DSU982 (Data Service Unit)


– Multi purpose microcontroller unit.
– Battery back-up of the RAM chip.
– MSU: (Main System Unit)
– Local connection to O&M system.
– Controls the system in Test Mode.
– Holds non-voluntary memory containing the Vital Element Data (VED).
– Holds CTU035 functionality and CSB functionality.
– Prepared for PSB198 functionality.

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in Common Section of Diamux 120 and


Diamux 120II, Only

 DSU983 (Data Service Unit)


– Multi purpose microcontroller unit.
– Battery back-up of the RAM chip.
– MSU: (Main System Unit)
– Local connection to O&M system.
– Controls the system in Test Mode.
– Holds non-voluntary memory containing the Vital Element Data (VED).
– Holds CTU935 functionality and CSB functionality.
– Holds the functionality of the PSB198. Internal signalling.

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in Common Section of Diamux 120 and


Diamux 120II, Only
 DSU576 (Data Service Unit)
– Controls the system in Operation Mode.
– Holds the Application Software of the system.
One Active and one Passive copy.
(Active and Passive can be different Releases)
– Executes the Application Software of the System.
– Holds: Command Log, Local Dump and Element Data.

Initial EPROM
Basic
Program
Application Active Passive FPROM
Program Program Program
RAM
CommandLog Local Dump Area with back-up
Application
Data
Element Data
RAM
Working
Data Stack/Heap (Process Data)

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in Common Section of Diamux 120, Only

 PSB 198 (Packet Switch Block).


– Switching of upto 32 channels for internal signalling between the Application
Software on the DSU576 Unit and the Interface Units.
Used for AGM- , IGM- , CGM- , ALT- (running Protocol) , AMU- , and CSU
hardware units.

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in Common Section and Interface Section


of Diamux 120/500 and Diamux 120II.
 AMU 995 (Analogue Measurement Unit)
– Subscriber and User port measurements - Line and Codec measurements.
– Controls 3 external relay output.
– 12 Digital and 6 Analog input.

 LAU 001 (Local Area Unit)


– Connection to the management System through LAN.
– Protocol is TCP/IP
– Speed if mounted in the Common Section is between 100Kbit/s and 200Kbit/s.
– Speed if mounted in the Interface Section is Maximum 64Kbit/s.
The reason for this lower speed is that the data flow must go through the CSB,
which performs internal switching on 64Kbit level.

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in Common Section and Interface Section


of Diamux 120/500.

 PSU 097 (Power Supply Unit)


– DC/DC converter: Generating voltage required by the system.

 DC/DC 784 (DC/DC converter)


– Generating voltage required by the system.

 PSU 098 (Power Supply Unit)


– Line voltage (63V, 68V, 97V).
– Generating Ringing voltage towards Subscribers.
– Generates PRM for AGM460 and AGM470.

 DRG 783 (Digital Ringing Generator)


– Line voltage (63V).
– Generating Ringing voltage towards Subscribers.

Diamux Training A/S


CURSO DE DIAMUX

Hardware Modules in the Interface Section


Unit Type Diamux500 SD Diamux500 HD Diamux120 SD Diamux20II
E1 / E2 ALT ALT ALT LTI OTI
997, 949, 999, 495, 997, 949, 999, 495, 997, 949, 999, 495, 202 690, 701 693
202,204 202, 204, 400

T1 ALT ALT ALT LTI


668 668 668 691, 259,

PSTN AGM AGM AGM ATI


450/51, 460/61, 470/71, 415 450/51, 460/61, 470/71, 694, 760/61,
480/81, 940/41 480/81, 940/41 170/71,

ISDN IGM IGM IGM BRI


561/62, 441/42, 541/42 -- 561/62, 441/42, 541/42 696, 695, 795,
168
Signalling Various Types Various Types Various Types None
EMU866, CSU962 EMU866, CSU962 EMU866, CSU962 --
Leased Line Various types Various types Various types Various types
AGM790/791, AGM790/791 ver.C., AGM790/791, ALI924, ALI169
GM648/649, GM648/649 ver.C., GM648/649, SDI692
SDU950 SDU950 ver. D. SDU950
LAN LAU LAU LAU None
001 001 001 --

Diamux Training A/S


CURSO DE DIAMUX

Hardware Units used in the Interface Section of


Diamux 120/500, Only
 E1 / E2 Unit type Single cards supplying either an electrical or optical interface,
2Mbit/s / 8Mbit/S connection.

 T1 Unit type Single cards supplying an electrical interface, 1,5 Mbit/s


connection.

 PSTN Unit Group module cards of one master and upto three type
slave cards.

 ISDN Unit Group module cards of one master and upto one type
slave cards.

 Signalling Single cards supplying E&M signalling and associated


CAS switching.

 Leased Line Single cards and group module cards for digital and analog
interfaces..

Diamux Training A/S


CURSO DE DIAMUX

Strapping of Hardware Units in GSP (Overview).


Strapping Overview (Diamux 500)
HardWare Unit Auto. ABUS Strapped Strapped to ABUS Add. Strapped line impedance Other Strapping Not Strapped

SHU (DSU560) X X
IHU (DSU560) X X
DSU 568 X
CSB 080 X
PSB 037 X
PSB 128 X
CTU 035 X X
CTU 935 X X
PSU 097 X
PSU 098 X
CCS7 038 X
AMU 995 X
LAU001 X
ALT 202 X
ALT 204 X
ALT 997 X
ALT 949 X
ALT 999 X

Diamux Training A/S


CURSO DE DIAMUX

Strapping of Hardware Units in GSP (Continued).


Strapping Overview (Diamux 500)

HardWare Unit Auto. ABUS Strapped Strapped to ABUS Add. Strapped line impedance Other Strapping Not Strapped

ALT 668 X
ALT 495 X
EMU 866 X
SDU 950 X
CSU 962 X
AGM450/451 X
AGM460/461 X
AGM470/471 X
AGM480/481 X
AGM940/941 X
AGM790/791 X
IGM561/562 X
IGM441/442 X
IGM541/542 X
CGM648/649 X

Diamux Training A/S


CURSO DE DIAMUX

Strapping of Hardware Units in MiniGSP (Overview).


Strapping Overview (Diamux 120)
HardWare Unit Auto. ABUS Strapped Strapped to ABUS Add. Strapped line impedance Other Strapping Not Strapped

MSU (DSU982) X
MSU (DSU983) X
DSU 576/568 X
PSB 198 X
CCS7 038 X
AMU 995 X
LAU001 X
ALT 202 X
ALT 204 X
ALT 997 X
ALT 949 X
ALT 999 X
ALT 668 X
ALT 495 X
EMU 866 X
SDU 950 X
CSU 962 X
AGM450/451 X

Diamux Training A/S


CURSO DE DIAMUX

Strapping of Hardware Units in MiniGSP (Continued).


Strapping Overview (Diamux 1200)

HardWare Unit Auto. ABUS Strapped Strapped to ABUS Add. Strapped line impedance Other Strapping Not Strapped

AGM460/461 X
AGM470/471 X
AGM480/481 X
AGM940/941 X
AGM790/791 X
IGM561/562 X
IGM441/442 X
IGM541/542 X
CGM648/649 X
PSU 097 X
PSU 098 X

Diamux Training A/S


CURSO DE DIAMUX

Strapping of Hardware Units in GSP (How to do).

Unit Pos. UAD ABUS Binary Address


no. adr. MSB LSB ALT997 Examples
SHU 00 00H 00H 00 0000
IHU1 01 01H 1BH 01 1011
IHU2 02 02H 1CH 01 1100
IHU3 03 03H 1DH 01 1101
IHU4 04 04H 1EH 01 1110
CCS7 05 05H 01H 00 0001 Bit no. : 0
1
IHU1
o o
o o
IHU2
o o
IHU3

o o
IHU4

DSU 568 06 06H auto. Strapped


2 o o o o o o
3 o o o o o o o o
4 o o o o o o o o
5

CCS7 07 07H 03H 00 0011 Addr. : 1BH 1CH 1DH 1EH

CCS7 08 08H 04H 00 0100 IHU


CCS7 09 09H 05H 00 0101 Strap guidance for Tx and Rx
0 0 0 0

CCS7 10 0AH 06H 00 0110 120 Ohm


Bal.
0
0
0
0
75 Ohm
UnBal.
(Grounded)
0
0
0
0

CCS7 11 0BH 07H 00 0111 0 0 0 0 ABUS-


access
0 0 0 0
Ext. reset

CCS7 12 0CH 08H 00 1000 ABUS-


access

CCS7 13 0DH 09H 00 1001 Ext. reset

CCS7 14 0EH 0AH 00 1010


CSB080 15 0FH 3EH 11 1110
3FH 11 1111
PSB 17 11H 3DH 11 1101
CTU 19 13H 13H 01 0011
AMU 22 16H auto. strapped

Diamux Training A/S


Board
Mother

MB (UAD 8)

IM7 (UAD 7)
IM6 (UAD 6)

IM5 (UAD 5)

IM4 (UAD 4)

(G.703)
IM3 (UAD 3)

2 Mbit/s
IM2 (UAD 2)
Interface Section

IM1 (UAD 1)
Diamux 20II

IM0 (UAD 0)
power
CURSO DE DIAMUX

Power Supply (UAD 9)


Hardware units used in Diamux 20II systems

Optional Radio Modem


Diamux Training A/S
CURSO DE DIAMUX

DSU - Data service unit


The DSU HW platform is the processor unit DSU 643

• Holds the application software


• CTU-, CSB-, and PIP functionality
• Switching capacity of 8 2 Mbit/s on 64 kbit/s level
• Receiving Ext. synchronization from unit in IM0
• DLL software stored in FPROM
• Green LED indicating Normal/Running status
• Red LED indicating Faulty situation

Diamux Training A/S


CURSO DE DIAMUX

LTI - Line termination interface


The following units can be used as HW platform

E1 T1

Coaxial LTI 690 LTI 691


75 Ohm
Twisted pair LTI 701 LTI 259
120 Ohm

PCM

Diamux Training A/S


CURSO DE DIAMUX

OTI - Optical termination interface


The OTI HW platform is the unit OTI 693

• 2 Mbit/s Fibre optical interface according


to CCiTT G.704 Framestructur
• CRC-4 Check is supported
• DLL for software update
• Can run either as Aggregate or Tributary interface
• Connector Type: Two SC connectors for Fiber
connection.

Warning : Do not look directly into the SC connectors.


The laser radiation is invisible.

PCM

Diamux Training A/S


CURSO DE DIAMUX

ATI - Analog telephone interface


The ATI HW platform is the unit ATI 760 / 761

ATI 760 / ATI 761


1 group = 1 Master + 3 Slaves
1 group = 14 subscribers
2 subscribers on master unit
4 subscribers on slave unit

Mother IM7 IM6 IM5 IM4 IM3 IM2 IM1 IM0


bord

M M/S1 M/S2 M/S3 M M/S1 M/S2 M/S3


SYNC

Diamux Training A/S


CURSO DE DIAMUX

BRI - Basic rate interface


The following units can be used as HW platform

BRI 795 BRI 695


ISDN 3 · S-interface
1 · S-interface
Router

NT

Data NT

NT
BRI 696 / BRI 168
3 · U-interface
Diamux Training A/S
CURSO DE DIAMUX

ALI - Analog leased line interface


The ALI HW platform is the unit ALI 924

• Overvoltage protection
• Line termination
• Gain/filter functions
• A/D and D/A conversion
• A-Law PCM coding/decoding
• Hybrid balancing
• Gain adjustment in 2 or 4-wire mode
• 2/4-Wire switching
Modem • Line impedance: 600 ohm

Analog leased
line equipment

Diamux Training A/S


CURSO DE DIAMUX

SDI - Synchronous data interface


The SDI HW platform is the unit SDI 692

Digital leased line


equipment V.11/V.36

Diamux Training A/S


CURSO DE DIAMUX

PSU - Power supply unit The following units can be used as HW platform

PSU 701
Input: 90 to 130 Volt 50 - 60 Hz

PSU 702
Input: 170 to - 250 Volt 50 - 60 Hz

BBU 731
Output: 3 · 12 V 13 Ah

Diamux Training A/S


CURSO DE DIAMUX

Strapping of hardware units in GSP

ALT949 Examples
Unit Pos. no. UAD ABUS adr. Binary Address
MSB LSB
SHU 00 00H 00H 00 0000
IHU1 01 01H 1BH 01 1011
IHU2 02 02H 1CH 01 1100
IHU3 03 03H 1DH 01 1101
IHU1 IHU2 IHU3 IHU4

IHU4 04 04H 1EH 01 1110 Bit no. : 0


1
2
o o
o o
o o
o o
o o o o o o

DSU 568 06 06H auto. Strapped


3 o o o o o o o o
4 o o o o o o o o
5
Addr. : 1BH 1CH 1DH 1EH

CSB080 15 0FH 3EH 11 1110


3FH 11 1111 IHU
Strap guidance for Tx and Rx

PSB 17 11H 3DH 11 1101 120 Ohm


0
0
0
0 75 Ohm
0
0
0
0
0 0 UnBal. 0 0
CTU 19 13H 13H 01 0011
Bal. (Grounded)
0 0 0 0 ABUS-
access
0 0 0 0

AMU 995 22 16H auto. strapped


Ext. reset

ABUS-
access

Ext. reset

Diamux Training A/S


CURSO DE DIAMUX

Cable lengths
Service Unit in Diamux RULE OF THUMB
Max. length
POTS AGM 460/461 4-9 km C
ISDN BRA IGM 441/442 4-9 km C
ISDN PRA ALT 949 200 m A
Analogue leased lines AGM 790/791 10 km with acceptable S/N B
E&M EMU 866 200 m
HDSL ALT 495 5 km B
Optical PCM (2 Mb/s) ALT 999 40 km (with 2 fibbers)
Optical PCM (8 Mb/s) ALT 202 15 - 20 km (with 2 fibbers
E1 electrical ALT 949 200 m A
Digital leased line SDU 950 50 m B

A) The cable length specified here is valid without repeaters.


B) The max cable length depends on the quality of the copper cable, i.e. the square 0.4 - 0.8 mm
C) The specified length is depending on bit rate and on the quality of the copper cable

Diamux Training A/S


CURSO DE DIAMUX

ALP - ALarm panel The ALP HW platform is the unit ALP 260

16 relay output
ALP 260

OM

Diamux Training A/S


CURSO DE DIAMUX
AEM Links &
1 DB (Access Element Manager) Routes

Network Database OM-MTP

Installation of Diamux equipment


VED
2 ID OM Sync •Connecting O&M system
Vital Element Data
•Internal Cabling
3 DLL

Links &
4 CCS7 ALT
Routes MTP

5 Interface Definition

6 Synchronisation Date &

Alarm Subscription
Time Physical Installation
7 OM-1 OM-2
Alarm Data
Access Table
8 OM-1 OM-2 OM Access

9 Power
Subscribers
10 Dump

11 STM-1

12 NMAccess Engineering

Installation
13

Diamux Training A/S


CURSO DE DIAMUX

GSP System Concept


Control
Section

Core
DSU Data Channel
Section IHU Service Block
AMU
CCS7
RSU
Interface SHU
Section
(IFM) PSB AEM / NMAccess

x6
Tributary IFM #1
CSB
IFM #2
IFM #3

Fibre DC/DC
DC/DC
DRG
POTS
CTU

ISDN Miscellaneous
Data
ISDN
Network

IFM #87
CSU
AMU Diamux 500
1st order
PCM Lines

Fibre or
Copper
Aggregate

Diamux Training A/S


CURSO DE DIAMUX

MiniGSP System Concept


Core/Control
Section
V.24/V.28
DXC DSU
Port B
V.24/V.28
Section DSU Port C
V.24/V.28
MSU Port C

Interface
Section AMU

(IFM) PSB

Tributary ALT
CSB
DC/DC
AGM DC/DC
SDU DRG
Fibre
IGM
POTS SYNC
IGM
Miscellaneous
ISDN
CSU G.703, §10
Data 75 BNC input
ISDN
Network ALT
ALT
ALT Mini GSP
ALT

1st order
PCM Lines

Fibre or
Copper
Aggregate

Diamux Training A/S


CURSO DE DIAMUX

Connecting OM-cable
GSP MiniGSP / HD MiniGSP
C B A

RS232 MSU

F
D Connect the Diax O M Cable
G
to the M SU connector

OM cable in: Diamux 500 and Diamux 120 / Diamux 120II

Diamux Training A/S


CURSO DE DIAMUX

Connecting internal synchronisation cable in GSP

External synchronisation source received


in the interface section is transported to
the CTU in common section.

GSP

Diamux Training A/S


CURSO DE DIAMUX

Protocol signaling route

CCS Application software

PSB
(Packet Switch Block)
CSB
(Circuit Switch Block)

Back plane

Internal PCM Control


Highway cable

XGM Back plane


AGM460 Interface Section (XGM)

Diamux Training A/S


CURSO DE DIAMUX

Unit address allocation of the MiniGSP


sub-rack position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
D D D A M S S S M S S S M S S S M S S S M S S S Power Power
S S S M
U U U U
9 5 5 9
8 7 7
9 or or
MiniGSP 3 6 6
5
Ring. Ring.
5 5 gen.. gen..
6 6
8 8
UAD 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19

Common Interface Section


Section Power Section

• 14 positions can receive PSB access and


thereby run a protocol
• The shaded positions have PSB/CSB access

Diamux Training A/S


CURSO DE DIAMUX

Unit address allocation of the HD MiniGSP


sub-rack position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

D D D A M S M S M S M S M S M S M S M S M S M S M S PSU099
S S S M
U U U U
HD 9 5 5 9
9
8 7 7
MiniGSP 3 6 6
5 Or
5 5 04 05 PSU099
6 6 24 25
8 8 44 45
UAD 00 01 02 03 64 65 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A

Common Interface Section Power


Section Section
*1) *2)

• 14 positions can receive PSB access and thereby run a protocol simultaneously.
• The shaded positions have PSB/CSB access

*1) UAD 24H, 44H and 64H have PSB/CSB access if neither
the PSB/CSB on UAD 09H, 16H or 18H have been used.

*2) UAD 25H, 45H and 65H have PSB/CSB access if neither
the PSB/CSB on UAD 10H, 12H or 14H have been used.
Diamux Training A/S
CURSO DE DIAMUX

Partial- / fully cabling for GSP


CCS Partial cabling:
S I I I I R D C C C C C C C C C P C A DC DC Nine positions in XGM with 2 Mbit/s
H H H H H S S C C C C C C C C S S T M
U U U U U U U S S S S S S S S B B U U connection to CSB/PSB in CCS.
1 2 3 4 5 7 7 7 7 7 7 7 7 9
6 9 - Mainly used when the XGM is used
8 5
for PSTN or ISDN subscribers.
XGM
M S S S M S S S M S S S M S S S M S S S M S S S M S DC
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D OE 0F 10 11 12 13 14 15 16 17 18 Fully cabling:
DRG 26 positions in XGM with 2 Mbit/s
300 301 302 303 304 305 306 307 308 309 30A 30B 30C 30D 30E 30F 310 311 312 313 314 315 316 317 318 319 31A
DRG DC
connection to CSB/PSB in CCS.
M S S S M S S S M S S S M S S S M S S S M S S S M S DC - Mainly used when the XGM is used
for 1.5- or 2 Mbit/s connections
DRG
DRG DC
200 201 202 203 204 205 206 207 208 209 20A 20B 20C 20D 20E 20F 210 211 212 213 214 215 216 217 218 219 21A
Master/slave position:
M S S S M S S S M S S S M S S S M S S S M S S S M S DC
The XGM sub-rack supply seven
master positions per sub-rack.
DRG six master position controls three
DRG DC
200 201 202 203 204 205 206 207 208 209 20A 20B 20C 20D 20E 20F ¨210 211 212 213 214 215 216 217 218 219 21A slave positions and the last master
position controls one slave position.
Diamux Training A/S
CURSO DE DIAMUX

Unit address allocation in the HD XGM sub-rack


CCS S
H
I I I I D C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
S
P
S
C
T
L
A
A
M
PSU
097
PSU
097
H H H H S
U U U U U U S S S S S S S S B B U U U
1 2 3 4 5 7 7 7 7 7 7 7 7 0 9
6 0 9
8 1 5

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D OE 0F 10 11 12 13 14 15 16 17 18

HD XGM M S M S M S M S M S M S M S M S M S M S M S M S M S

x00 x01 x02 x03 x04 x05 x06 x07 x08 x09 x0A x0B x0C x0D x0E x0F x10 x11 x12 x13 x14 x15 PSU PSU
x20 x21 222 223 224 225 226 227 228 229 22A 22B 22C 22D 22E 22F 230 231 232 233 234 235 099 099
x40 x41 242 243 244 245 246 247 248 249 24A 24B 24C 24D 24E 24F 250 251 252 253 254 255
x60 x61 262 263 264 265 266 267 268 269 26A 26B 26C 26D 26E 26F 270 271 272 273 274 275 x16 x17 x18 x19 x1A

2 PCM cables
4 PCM cables
6 PCM cables
8 PCM cables
10 PCM cables

= only ALT- ,LAU- ,


= 4 UAD’s allocated = 3 topmost UAD’s allocated = 1. topmost UAD allocated SDU-units
Diamux Training A/S
CURSO DE DIAMUX

Unit address allocation in the HD XGM sub-rack


CCS S
H
I I I I D C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
S
P
S
C
T
L
A
A
M
PSU
097
PSU
097
H H H H S
U U U U U U S S S S S S S S B B U U U
1 2 3 4 5 7 7 7 7 7 7 7 7 0 9
6 0 9
8 1 5

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D OE 0F 10 11 12 13 14 15 16 17 18

HD XGM M S M S M S M S M S M S M S M S M S M S M S M S M S

x00 x01 x02 x03 x04 x05 x06 x07 x08 x09 x0A x0B x0C x0D x0E x0F x10 x11 x12 x13 x14 x15 PSU PSU
x20 x21 222 223 224 225 226 227 228 229 22A 22B 22C 22D 22E 22F 230 231 232 233 234 235 099 099
x40 x41 242 243 244 245 246 247 248 249 24A 24B 24C 24D 24E 24F 250 251 252 253 254 255
x60 x61 262 263 264 265 266 267 268 269 26A 26B 26C 26D 26E 26F 270 271 272 273 274 275 x16 x17 x18 x18 x1A

Positions with
shared CSB
access

UAD x41H has PSB/CSB access if the PSB/CSB on UAD x18H not has been used and
UAD x61H has PSB/CSB access if the PSB/CSB on UAD x16H not has been used.

= 2,3 or 4 UAD’s allocated = Has shared CSB inlet with UAD H’x41 or H’61
Diamux Training A/S
CURSO DE DIAMUX

Internal cabling of GSP

Inte rc o nne c ting


Cab le s

S ub s c rib e r-
Cable s
Connectors: CCS is equipped with 10 physical
Po w e r Cab le s
connectors for internal PCM
cables.

PCM cables: Carrying Internal 2 Mbit/s


Connections.
Each cable carrying nine duplex
Connections and Ground.

CTRL cables: Carrying control signals, ABUS


signals and internal clock.

Diamux Training A/S


CURSO DE DIAMUX

Common section sub-rack, CCS of Diamux 500

IHU1
IHU2 L K
N M

P O
R IHU4 Q IHU3

Internal PCM connection to XGM

Diamux Training A/S


CURSO DE DIAMUX

Interface sub-rack section, XGM of Diamux 500

Control cable-connection
when fully cabled sub-rack.

F F F/P

Internal PCM connection to CCS

Control cable-connection when


partial cabled sub-rack.

Diamux Training A/S


CURSO DE DIAMUX

Fully cabled sub-racks in Diamux 500

sub-rack Cable type CCS XGM Controlled by

XGM 200.. Control cable K E


F A C
3 PCM cables IHU1
B B
J A
XGM 400.. Control cable M E
F C C
3 PCM cables D B IHU2
I A
XGM 600.. Control cable O E
F 3 PCM cables E C
F B IHU3
H1 A
XGM 800.. Control cable Q E
‘F’ 1 PCM cable IHU4
G C
Supply nine position with 2 Mbit/s access.

Diamux Training A/S


CURSO DE DIAMUX

Partially cabled sub-racks in Diamux 500


sub-rack Cable Type CCS XGM Controlled by

XGM 200.. P Control cable K D IHU1


PCM cable A C
XGM 300.. P Control cable L D IHU1
PCM cable B C
XGM 400.. P Control cable M D IHU2
PCM cable C C
XGM 500.. P Control cable N D IHU2
PCM cable D C
XGM 600.. P Control cable O D IHU3
PCM cable E C
XGM 700.. P Control cable P D IHU3
PCM cable F C
XGM 800.. P Control cable Q D IHU4
PCM cable G C
XGM 900.. P Control cable R D IHU4
PCM cable H C
Diamux Training A/S
CURSO DE DIAMUX

Cabling HD XGM sub-racks in Diamux 500

Controlled sub-rack Cable type CCS XGM


by

IHU1 HD XGM Control cable K K


H’200- H’275 2- 10 PCM A A
cables B B 2 PCM cables
I I
J J 4 PCM cables
G C
H D 6 PCM cables
E E
F F 8 PCM cables
C G
D H 10 PCM cables

Diamux Training A/S


CURSO DE DIAMUX

Cabling HD XGM sub-racks in Diamux 500


Controlled
sub-rack Cable type CCS XGM
by

IHU2 HD XGM H’400-H’461 Control cable M K


2 PCM cables C A
D B

IHU3 HD XGM H’600-H’661 Control cable O K


2 PCM cables E A
F B

IHU4 HD XGM H’800-H’861 Control cable Q K


2 PCM cables G A
H B

Diamux Training A/S


CURSO DE DIAMUX

Example of internal cabling using XGM sub-racks

K Partial cabled B
A
HD sub-rack

Partial cabled
K
HD sub-rack B
A

D
Partial cabled C
K J
HD sub-rack I
B
A

K IHU 1 A

Common section B
I
J
M IHU 2 C
G
D H

O IHU 3 G
H

Diamux Training A/S


CURSO DE DIAMUX

External cabling

Cabling using wrapping panels


PSTN, ISDN, 2-/4-wire analog leased line
1.5- and 2 Mbit/s 120 ohm connection, HDSL, SDU, E&M

Cabling using BNC connector panels


2 Mbit/s 75 ohm connection

Cabling using 9-pin D-sub connector


Termination for two 1.5 Mbit/s or 2 Mbit/s 120 ohm
interfaces on twisted pair.

Cabling using 37-pin D-sub connector


Termination for eight 1.5 Mbit/s or 2 Mbit/s 120 ohm
interfaces on twisted pair.

Diamux Training A/S


CURSO DE DIAMUX

External cabling on 32-pin wrapping panel


2 wire connection

4 wire connection PSTN, or analog leased line,


1,5Mbit/s or 2Mbit/s connection,
Analog Leased Line four wire HDSL and two wire HDSL
Group Module
Pin-no. xGMS3 xGMS2 xGMS1 xGMM Pin-no. xGMS3 xGMS2 xGMS1 xGMM
 1  1  1  1
x x
(c-a pin) (c-a pin)
x x  2  2  2  2
G G G G  4  4  4  4 1 3 2 1
M M
1
M M  6  6  6  6
M S S S 2 3 2 1
 8  8  8  8 2 3 2 1
1 2 3 4 7 6 5 4
 10  10   10  10
4
 12  12   12  12 6 7 6 5 4
 14  14   14  14 6 7 6 5 4
 16  16   16  16
8 11 10 9 8
8
 18  18   18  18 10 11 10 9 8
 20  20   20  20
12 15 14 13 12 10 11 10 9 8
 22  22   22  22
 24  24   24  24 14 15 14 13 12 12
 26  26   26  26 16 19 18 17 14 15 14 13 12
 28  28   28  28
 30  30   30  30 18 19 18 17 16
ca ca ca ca 20 23 22 21 20 18 19 18 17
xGMS3 xGMS2 xGMS1 xGMM
22 23 22 21 20 20
Front view Rear view
24 27 26 25 24
22 23 22 21 20
26 27 26 25 24
24
28 31 30 29 28
26 27 26 25 24
30 31 30 29 28
28
RX
30 31 30 29 28
TX
Tx 1,5Mbit/s or 2Mbit/s
a-b wire
Rx connection, HDSL

Diamux Training A/S


CURSO DE DIAMUX

External cabling on 32-pin wrapping panel

Two ISDN group module


2 wire connection, ISDN
Module 1 Module 2
Pin no. XGMS1 XGMM
 1  1  1  1
x x x x  2  2  2  2 1
G G G G  4  4  4  4
M M M M  6  6  6  6
2 2, 3
M S M S  8  8  8  8
1 1 4
 10  10   10  10
 12  12   12  12 6 6, 7 4, 5
 14  14   14  14
 16  16   16  16 8
 18  18   18  18
 20  20   20  20 10 10, 11 8, 9
 22  22   22  22
 24  24   24  24 12
 26  26   26  26
 28  28   28  28 14 14, 15 12, 13
 30  30   30  30
ca ca ca ca 16
XGMS1 XGMM XGMS1 XGMM
Front view
18 18, 19
Rear view
20
22 22, 23 20, 21
24
26 26, 27 24, 25
28
30 30, 31 28, 29

Diamux Training A/S


CURSO DE DIAMUX

External cabling on 32-pin wrapping panel – AGM415

2 wire connection
PSTN on AGM415
Group Module
Pin-no. XGMS1 XGMM
 1  1 (c-a pin)
x x  2  2
G G  4  4 1
M M  6  6
M S 2 17 1
 8  8
1
  10   10 4 18 2
  12   12
  14   14 6 19 3
  16   16
  18   18
8 20 4
  20   20 10 21 5
  22   22
  24   24 12 22 6
  26   26
  28   28 14 23 7
  30   30
16 24 8
ca ca
xGMS1 xGMM 18 25 9
Front view Rear view
20 26 10
22 27 11
24 28 12
26 29 13
28 30 14
30 31 15

Diamux Training A/S


CURSO DE DIAMUX

External cabling 32-pin termination panel, 1.5 / 2 Mbit/s

.. ..
PCM 1 .. ..
Use of “pin” in the D-sub connector
( TX and RX) .. ..
.. .. J200/01 Name D-SUB

9-pin D-sub
.. .. 6a TX (a) 3
.. ..
6c TX (b) 8
.. ..
10a RX (a) 4
.. ..
.. .. 10c RX (b) 9
.. ..
.. .. J200/02 Name D-SUB
.. .. 6a TX (a) 1
.. .. 6c TX (b) 6
( TX and RX) .. .. 10a RX (a) 2
PCM 2 .. .. 10c RX (b) 7
.. .. NC GND 5

Diamux Training A/S


CURSO DE DIAMUX

MCX connector panel

TX1B RX1A
RX1B TX1A

RX2B B A RX2A
TX2B TX2A

RX3B RX3A
TX3B TX3A

RX4B
TX4A
TX4B RX4A

Location of the PCM systems at the ALT400 PCM Panel


Diamux Training A/S
CURSO DE DIAMUX

External cabling 32-pin termination panel,1.5 / 2 Mbit/s


J200/01 Name D-SUB

.. .. .. .. .. .. .. .. 6a
6c
TX (a)
TX (b)
5
23

.. .. .. .. .. .. .. .. 10a
10c
RX (a)
RX (b)
4
22

.. .. .. .. .. .. .. ..
NC GND 1

J200/02 Name D-SUB

.. .. .. .. .. .. .. .. 6a
6c
TX (a)
TX (b)
7
25

.. .. .. .. .. .. .. .. 10a
10c
RX (a)
RX (b)
6
24

.. .. .. .. .. .. .. .. J200/01 Name D-SUB

.. .. .. .. .. .. .. .. 6a
6c
TX (a)
TX (b)
9
27

.. .. .. .. .. .. .. ..
10a RX (a) 8
10c RX (b) 26

.. .. .. .. .. .. .. .. J200/02 Name D-SUB

.. .. .. .. .. .. .. ..
6a TX (a) 11
6c TX (b) 29
10a RX (a) 10
.. .. .. .. .. .. .. .. 10c RX (b) 28

.. .. .. .. .. .. .. .. J200/01
6a
Name
TX (a)
D-SUB
13

.. .. .. .. .. .. .. .. 6c
10a
TX (b)
RX (a)
31
12

.. .. .. .. .. .. .. .. 10c RX (b) 30

.. .. .. .. .. .. .. .. J200/02
6a
Name
TX (a)
D-SUB
15

.. .. .. .. .. .. .. .. 6c
10a
TX (b)
RX (a)
33
14
10c RX (b) 32

37-pin D-sub J200/01 Name D-SUB


6a TX (a) 17
6c TX (b) 35
10a RX (a) 16
10c RX (b) 34

Use of “pin” in the D-sub connector J200/02


6a
6c
Name
TX (a)
TX (b)
D-SUB
19
37

! See product documentation ! 10a


10c
RX (a)
RX (b)
18
36

Diamux Training A/S


CURSO DE DIAMUX

External cabling 32-pin termination panel, SDU

.. .. Use of “pin” J200 ICC V.35 V35 J200 ICC V.35 V35
pin no. pin no.
.. .. V.35
1a 102 B 1c 102 B
.. .. 2a 103(A) P 2c 103(B) S
4a 105(A) C 4c 105(B)
.. .. 5a 108(A) H 5c 108(B)
6a 104(A) R 6c 104(B) T
.. .. 7a 109(A) F 7c A
.. .. 8a
9a
107(A)
106(A)
E
D
8c
9c
107(B)

.. .. 10a
12a
114(A)
115(A)
Y
V
10c
12c
114(B)
115(B)
AA
X
.. .. 14a
15a
113(A)
142(A)
U
NN
14c
15c
113(B) W

.. .. 16a
18a
102
103(A)
B
P
16c
18c
102
103(B)
B
S
.. .. 20a
21a
105(A)
108(A)
C
H
20c
21c
105(B)
108(B)
.. .. 22a
23a
104(A)
109(A)
R
F
22c
23c
104(B) T
B
.. .. 24a
25a
107(A)
106(A)
E
D
24c
25c
107(B)

.. .. 26a
28a
114(A)
115(A)
Y
V
26c
28c
114(B)
115(B)
AA
X
.. .. 30a
31a
113(A)
142(A)
U
NN
30c
31c
113(B) W

.. ..
.. ..

Diamux Training A/S


CURSO DE DIAMUX

External optical connection

Termination for the


optical Fibre
• Is onboard the
Optical unit

Diamux Training A/S


CURSO DE DIAMUX
AEM Links &
1 DB (Access Element Manager) Routes

Network Database OM-MTP

VED
2 ID OM Sync
Vital Element Data
3 DLL

Links &
4 CCS7 ALT
Routes MTP

5 Interface Definition

Synchronisation Date &


6
Time AEM and O&M
Alarm Subscription
7 OM-1 OM-2
Alarm Data

8
Access Table
OM-1 OM-2 OM Access
Signaling
9 Power
Subscribers
10 Dump

11 STM-1

12 NMAccess Engineering

Diamux Training A/S


CURSO DE DIAMUX

Installation of AEM
Install AEM,
AEM database
and DLL files
Insert CD-ROM OM
computer

• Install the CD-ROM. Diamux

• Start OMII server.


• Define the users “master”
and “NMAccessService”
in AEM security management.

Diamux Training A/S


CURSO DE DIAMUX

AEM - server and clients

MML CM Client Future Client

FM Client

Remote
Access
Diax OM Server
LAN

Diax Security Log


ANS or Access 300
Network Management
Windows NT Diax OM
Users Users

Diamux Training A/S


CURSO DE DIAMUX

MML configuration management client.

Press F1 for On Line Help

Diamux Training A/S


CURSO DE DIAMUX

System configuration using multi-command files

Examples:
Network DataBase POTS Configuration Subscriber no.1
configuration
Local MTP ISDN Configuration
Subscriber no.2
configuration
National MTP Data configuration
Subscriber no.3
Synchronization configuration
64 kbit Cross
Connections Subscriber no.4
PCM Configuration configuration

Commands to handle Multicommand Files

- MC-EX: … [Execute]
- MC-CA: … [Cancel]
- MC-RS: … [Resume]

Diamux Training A/S


CURSO DE DIAMUX

Time released commands

• Automatic execution of e.g. a MML Command or MultiCommand File.


• The action can be repeated with an optional time interval.

- EVT-CRTRC: … [Create]
- EVT-RMTRC: … [Remove]
- EVT-RDTRC: … [Read]

Diamux Training A/S


CURSO DE DIAMUX

Data communication network

AEM-Clients Diax OM Server


(MML or FM) and clients

LAN
A DCN
Clients Clients

B Access 300
System Network

Diamux Training A/S


CURSO DE DIAMUX

Remote access
OMII server
MML client
SHU
Zyxel

Zyxel

POTS- or leased line


connection 9.6 kbit/s

SHU
Com port
Zyxel
MML client
Zyxel
OMII server
MML client

Diamux Training A/S


CURSO DE DIAMUX

O&M connection
MTP- MTP-
signaling signaling

Com Port SHU SDU950


CCS7
V.36
9.6 kbit/s 64 kbit/s
PCS264
Distance: 0 - 25 meter Distance: 0 - 1000 meter

MTP-
TCP/IP- signaling
signaling
LAN
ALT949
LAU

64 - 200 kbit/s E1/D5


LAN card PCI064 32 * 64 kbit/s

Distance: 0 - 200 meter Distance: 0 - 200 meter


Diamux Training A/S
CURSO DE DIAMUX

No embedded management signaling

E1 with 31 SL
AEM / NMAccess V5.x

POTS
V5.x Diamux
ISDN
V5.x
Diamux
D5.x POTS
Diamux ISDN
Indirect connected
Diamux

Diamux Training A/S


CURSO DE DIAMUX
AEM Links &
1 DB (Access Element Manager) Routes

Network Database OM-MTP

VED
2 ID OM Sync
Vital Element Data
3 DLL

Links &
4 CCS7 ALT
Routes MTP

5 Interface Definition

6 Synchronisation Date &


Time
7
Alarm Subscription
OM-1 OM-2
Alarm Data AEM Configuration
Access Table
8 OM-1 OM-2 OM Access

9 Power
Subscribers
10 Dump

11 STM-1

12 NMAccess Engineering

Diamux Training A/S


CURSO DE DIAMUX

Sending a message

AEM; PC 111 ; Class OM Log on: master


PC 11
Class D500_160
SM-Client
MML CM-Client
Security check PC 12
sys-rdun:mux1,all,all;
sys-rdun:mux1,all,all; CLASS D120_160
Syntax PC 112
check Class OM

Network
Database Class
Database
om1 ,111,om
om2 ,112,om d500_160 “sys-rdun signaling”; OPC=111; DPC=11;
mux1,11,d500_160
mux1,11,d500_160 d120_160
mux2,12,d120_160 om

Diamux Training A/S


CURSO DE DIAMUX

Receiving a message

AEM; PC 111 ; Class OM


PC 11
Class D500_160
SM-Client
MML CM-Client
PC 12
000 SHU CLASS D120_160
001 IHU Fully Cabled
PC 112
Class OM

Network
Database Class
Database
om1 ,111,om
om2 ,112,om d500_160 DPC=111; OPC=11; “sys-rdun signaling”;
mux1,11,d500_160
mux1,11,d500_160 d120_160
mux2,12,d120_160 om

Diamux Training A/S


CURSO DE DIAMUX

Creating the network database


Command Name of the Name of the new Class off the new
name OM-server network element network element

SYS-CRNE: OM11 , LOCALMUX , 0001 , D500_160 ;

Colon separates Comma Point code Semicolon


the command and separates the of the new terminates
the parameters parameters network the command

Network database

Name PC Class
OM11 0111 OM
Localom 0000 OM
Mux1 0011 D500_160
Localmux 0001 D500_160

Diamux Training A/S


CURSO DE DIAMUX

Element attributes

Name: mux1
PC: 11 SYS-CRNE
Class: D500_160
NI: NAT
ETE: 7
SYS-SEATT DDTPWS: 12
IPADR: 192.168.180.21
CMDLOG: ON
DLL: D500_160
ATTR: C:\Diax-OM\DUMP
MAINT: YES

Diamux Training A/S


CURSO DE DIAMUX

O&M signaling on local level

Local name: Localmux


National name:
Localmux
MUX2
Name: OM1 Mux2

Local link

National
link
Connect signaling link
mtp-cosl : OM1, Localmux, 0, norm, alc, 1;

Create signaling route


mtp-crsr : OM1, Localmux, Localmux, norm;
Diamux Training A/S
CURSO DE DIAMUX

O&M signaling on national level

National name: MUX1


National name:
Mux1
MUX2
Name: OM1 Mux2

National link

National
Connect signaling link link
mtp-cosl : OM1, Mux1, 0, norm, alc, 1;

Create signaling route


mtp-crsr : OM1, Mux1, Mux1, norm;
mtp-crsr : OM1, Mux2, Mux1, norm;
Diamux Training A/S
CURSO DE DIAMUX

National O&M signaling via TCP/IP

National name: MUX1


National name:
Mux1
MUX2
Name: OM1 Mux2

TCP/IP
connection
National
Connect TCP/IP link
dcn-coip : OM1, Mux1;

Create TCP/IP path


dcn-crpa : OM1, Mux2, Mux1, norm;

Diamux Training A/S


CURSO DE DIAMUX

Safety copy for the AEM configuration

Dump files
Dump files
AEM Dump files
Part of user Dump files 5
specified data Dump files 4
SYS-DUOM
Diax_om.INI 3
Diax_sm.INI 2
“Elements”.INI SYS-LDOM 1

Event trigger
set-up
C:\ Diax-OM \ Dump \ OM \ Dump 1-5 \ “data”

Diamux Training A/S


CURSO DE DIAMUX

Diamux configuration

Diamux Training A/S


CURSO DE DIAMUX

Tasks during Configuration of the Diamux


Step 1. Definition of Vital Element Data

Step 2. Down Line Load of Application software

Step 3. Definition of DCN / MTP signalling

Step 4. Configuration of Interfaces/Protocol

Step 5. Synchronisation in the Access 300 network

Step 6. Definition of Alarm handling

Step 7. Definition of OM Access

Step 8. Dump and Reload of System Data / Configuration Data

Diamux Training A/S


CURSO DE DIAMUX

Vital Element Data : Overview


Element type : GSP500/MiniGSP VED are stored on
National Pointcode : 0000 - 3FFF
International Pointcode : 0000 - 3FFF the SHU / MSU.

Pointer
OM OM Warning
NE
Physical Connection Mounting or dismounting
the CTU might corrupt VED
in the SHU, if done when
SHU is mounted.
G.703 §.10
ALT ALT Always dismount the SHU,
UAD 203 UAD 200 if the CTU needs to be
Sync. removed or inserted!
source
ALT ALT
UAD 202 UAD 201

Diamux Training A/S


CURSO DE DIAMUX

Vital Element Data : Network Element Type and “Name”

Diamux 500 = GSP or Diamux 120 = MiniGSP

MUX1 MUX2

Command:
VED-SEIDD : LocalMUX , GSP/MiniGSP , NationalMUX , XX;

Point Code:
The pointcode of “NationalMUX” is fetched from the Network Database in
the OM computer and stored on the SHU/MSU card in the Diamux.
Diamux Training A/S
CURSO DE DIAMUX

Physical connections and signalling in the network


Connection to the O&M system Connection to the other Diamux’es
•MTP (Message Transfer Part) •MTP (Message Transfer Part)
Protocol : Protocol :
Connection : RS232 or V.36 Connection : G.703, Optical or
HDSL
•DCN (Data Communication Network)
Protocol : TCP/IP
Connection : LAN

MUX2
• MTP on Local Level must
run on a RS232 or V.36 • If MTP on National Level is
connection used, this will run on the
Om1 same physical connection as
MUX1
V
the Local level MTP.
E

• If DCN on National D
V • MTP connection on
Level is used, this will
G.703, optical or
require a physical
E HDSL connection.
LAN connection.
D

Diamux Training A/S


CURSO DE DIAMUX

Vital Element Data : DCN configuration in the Diamux


In VED
Step 1. Define which IP-port number the Diamux is connected to (Default = 49126).
The command is: VED-SEIPC: Localmux, MUX, none, default, none;
(VED Set IP Configuration)

Step 2. Define in which UAD the LAU001 card is mounted.

The command Is: VED-COIP: Localmux, OM,15;


(VED Connect IP)

Step 3. Define that TCP/IP signalling in the OM connection will be converted to MTP
signalling in the Diamux network.
The command Is: VED-CRGW: Localmux, ipmtp, om;
(VED Create Gateway)

Diamux Training A/S


CURSO DE DIAMUX

Vital Element Data : MTP configuration in VED of the Diamux


In VED
Step 1. Define Links towards the adjacent OM computer using the national OM- name.
The command is:
VED-COSL: Localmux, National OM , 0 , ALC , XX , XX , XX ;

Step 2. Define Links towards a OM computer connected to an other Diamux in the


network. Connect a link to the adjacent Diamux on the way towards this OM
computer.
The command is:
VED-COSL : Localmux , Mux1 , 0 , d5 , XX, 200 , XX ;

Step 3. Define routes towards the OM computers that you have connected links
towards, a adjacent connected OM- and a “remote” connected OM-computer.
The command Is:
VED-CRSR : Localmux , Adjacent OM , Adjacent OM , norm ;
VED-CRSR : Localmux , Remote OM , Adjacent MUX , norm ;

Diamux Training A/S


CURSO DE DIAMUX

Set ID data
MUX501
MUX121

Local link Data Data


stored on stored on
SHU MSU
Diamux 120
(HD)miniGSP
Diamux 500
GSP

ved-seidd : localmux , gsp/(HD)minigsp , nationalmux , xx;

Diamux Training A/S


CURSO DE DIAMUX

Define O&M signaling


Data stored on SHU

VED-SEIPC
VED-COIP VED-COSL
VED-CRGW VED-CRSR
Data stored on MSU
TCP/IP VED-COSL
MTP
VED-CRSR
DCN-SEIPC
DCN-COIP MTP-COSL
Mux1
DCN-CRGW MTP-CRSR MTP-COSL
OM11
MTP-CRSR
Data stored on DSU 568 Mux121
Data stored on DSU 568/576

Diamux Training A/S


CURSO DE DIAMUX

Vital element data - synchronization in the access 300 network


Exchange

Synchronisation
Direction

MUX1 MUX2

MUX3 MUX4

VED-SESYD : Localmux , 200/4, XX, XX , XX ;

Diamux Training A/S


CURSO DE DIAMUX

Tasks during Configuration of the Diamux


Step 1. Definition of Vital Element Data

Step 2. Down Line Load of Application software

Step 3. Definition of DCN / MTP signalling

Step 4. Configuration of Interfaces/Protocol

Step 5. Synchronisation in the Access 300 network

Step 6. Definition of Alarm handling

Step 7. Definition of OM Access

Step 8. Dump and Reload of System Data / Configuration Data

Diamux Training A/S


CURSO DE DIAMUX

Down line load

Diax
Development tools

Network
element

Network

Diax OM SW blocks in a Network Element

OS

DLL Program-
Store

Diamux Training A/S


CURSO DE DIAMUX

Down Line Load Using the Application Configuration Program

Diamux Training A/S


CURSO DE DIAMUX

Down Line Load of DSU Units

DSU568
Active Program

Program Active Program Passive Program FPROM

RAM
CommandLog Local Dump Area with
backup

Data
Element Data

RAM

Stack/Heap (Process Data)

Diamux Training A/S


CURSO DE DIAMUX

Down Line Load of Non DSU Units

Diamux Training A/S


CURSO DE DIAMUX

Tasks during Configuration of the Diamux


Step 1. Definition of Vital Element Data

Step 2. Down Line Load of Application software

Step 3. Definition of DCN / MTP signalling

Step 4. Configuration of Interfaces/Protocol

Step 5. Synchronisation in the Access 300 network

Step 6. Definition of Alarm handling

Step 7. Definition of OM Access

Step 8. Dump and Reload of System Data / Configuration Data

Diamux Training A/S


CURSO DE DIAMUX

Message Transfer Part Commands

MTP-COSL Connecting a signalling link


MTP-DCSL Disconnects a signalling link
MTP-RDLS Read a link set in a network element
MTP-BLSL Blocks a signalling link
MTP-UBSL Unblocks a signalling link

MTP-CRSR Creates a route towards another NE


MTP-RMSR Removes signalling routes
MTP-RDSR Readout of signalling routes in a NE
MTP-BLSR Blocks a signalling route
MTP-UBSR Unblocks a signalling route

Diamux Training A/S


CURSO DE DIAMUX

Message Transfer Part


Om-1

MUX3

UAD=201 UAD=401
ALT ALT

d5
MUX3
MUX2
MUX1
Localmux d5
Om-1
UAD=401
ALT
Om-1 MUX1
alc Om-1 UAD=201
ALT
UAD=0
SHU MUX2
d5
UAD=400 UAD=200
UAD=402 ALT ALT
ALT d5 UAD=202
ALT
Diamux Training A/S
CURSO DE DIAMUX

Message Transfer Part MUX1


Om-1

MUX3

UAD=201 UAD=401
ALT ALT

d5
MUX3
MUX2 MUX2
MUX1 MUX3
Localmux d5
Om-1
UAD=401
ALT
Om-1 MUX1 UAD=201
alc ALT

MUX3
Om-1
UAD=0
SHU MUX2
d5
UAD=400 UAD=200
UAD=402 ALT ALT
ALT MUX2 d5 UAD=202
ALT
MUX1
Diamux Training A/S
CURSO DE DIAMUX

MTP Configuration in the Diamux

MUX1
Localmux
Om-1

Om-1 MUX1
alc Om-1
UAD=0
MUX2
d5
UAD=400 UAD=200

Signalling Route
Signalling Link

Diamux Training A/S


CURSO DE DIAMUX

Tasks during Configuration of the Diamux


Step 1. Definition of Vital Element Data

Step 2. Down Line Load of Application software

Step 3. Definition of DCN / MTP signalling

Step 4. Configuration of Interfaces/Protocol

Step 5. Synchronisation in the Access 300 network

Step 6. Definition of Alarm handling

Step 7. Definition of OM Access

Step 8. Dump and Reload of System Data / Configuration Data

Diamux Training A/S


CURSO DE DIAMUX

Interface Configuration:
Diamux

TTP ( Trail Termination Point)


Command: Send from the OM
IF-CR:Mux,……..
TS 31

Interface Card / TS 5
OM computer Hardware Unit TS 4
TS 3
TS 2
* The hardware will be TS 1
associated with a Name
Protocol
A software object simulating software object
the hardware is created

Diamux Training A/S


CURSO DE DIAMUX

Create interfaces using the command if-cr

Local Exchange
MUX2
Tributary
UAD=201
Aggregate

D51

UAD=401
Tributary
Aggregate MUX1

Diamux Training A/S


CURSO DE DIAMUX

Interface Configuration
UAD=408
Local Exchange AGM460
MUX3
Tributary
UAD=201 UAD=401
ALT997 ALT999
d5
Aggregate Tributary

V5.1

d5
UAD=204 UAD=401
ALT997 ALT997
Tributary
Aggregate MUX1 UAD=201
ALT999
UAD=400 UAD=200 Aggregate
ALT495 d5 ALT495 MUX2
Tributary Aggregate
UAD=402 UAD=202
ALT997
Tributary d5 ALT997
Aggregate
Diamux Training A/S
CURSO DE DIAMUX

Create Interfaces Using the Command IF-CR


Local Exchange
PSTN-SUB
MUX3 A460Tbt

MUX3-1
D51Agt
MUX3-2
d5 D51Agt

V5.1
d5
To-LE
V51Agt MUX1- 3
D51Tbt
MUX1 MUX2-3
D51Tbt
MUX2
MUX1-2- HD d5 MUX2-1- HD
D51Tbt D51Agt
MUX1-2
D51Tbt d5 MUX2-1
D51Agt
Diamux Training A/S
CURSO DE DIAMUX

Activation using MML-Client. PSTN, ISDN and Leased on V5.1


H´208

AGM460

H´204
V5.1
ALT997
H´20C

Interface ID = 4 IGM441
Variant = 10
No Reprovisioning
H´304
USP TS Addr
PSTN 12 34000 AGM790
ISDN 17,18 8000
Leased 1 100
Local Exchange MUX1
Diamux Training A/S
CURSO DE DIAMUX

Activation using MML-Client. PSTN, ISDN and Leased. V5.2 SL


H´208

AGM460
H´20C
H´204
V5.2SL H´08
IGM441
ALT997
H´202 H´06
Interface ID = 101 AGM790
Variant = 10 ALT495 ALT495
Link ID = 4 MUX2
No Reprovisioning
USP Addr H´300 ATI
PSTN 34000
ISDN 8000 ALT999 OTI
Leased 100
MUX20-1
Local Exchange MUX1

Diamux Training A/S


CURSO DE DIAMUX

Activation using MML-Client. PSTN,ISDN and Leased V5.2 SL

H´208
AGM460

H´204 H´20C
V5.2SL H´08
IGM441
ALT997
H´202 H´06
Interface ID = 101 AGM460
Variant = 10 ALT495 ALT495
Link ID = 4 MUX2
No Reprovisioning
USP Addr H´300 ATI
PSTN 34000
ISDN 8000 ALT999 OTI
Leased 100
MUX20-1
Local Exchange MUX1

Diamux Training A/S


CURSO DE DIAMUX

Activation using MML-Client. PSTN, ISDN and Leased on V5.2


Mandatory PCM´s Group 1 C channels
H´208
Interface ID = 1 Link ID = 1 Active C-Channel Ch_ID = 21
H´200 AGM460
Link ID = 2 Standby C-Channel Stby1
H´201
PSTN C-path Link ID = 3 Active C-Channel Ch_ID = 22
H´202 H´20C
ISDN C-path ds Link ID = 4 Active C-Channel Ch_ID = 23
H´203 IGM441
ISDN C-path p,f Link ID = 5 Active C-Channel Ch_ID = 24
H´204
Link ID = 6 Standby C-Channel Stby2 H´304
H´205
Link ID = 7
AGM790
H´206

Group 2 C channels
Local Exchange MUX1
Diamux Training A/S
CURSO DE DIAMUX

What and how to Configure an Interface

ALT ALT ALT ALT ALT ALT


202 495 668 997 949 999
CRC multiframe
(On, off) X X X X X
Protocol Type
(None, xx) X X X X X X
Location of IFM
unit X X X
(TBT, AGT)
Frame Type
(SF, ESF) X
Line Length
(Cable length in X
meters)
Table 1.

Diamux Training A/S


CURSO DE DIAMUX

Tasks during Configuration of the Diamux


Step 1. Definition of Vital Element Data

Step 2. Down Line Load of Application software

Step 3. Definition of DCN / MTP signalling

Step 4. Configuration of Interfaces/Protocol

Step 5. Synchronisation in the Access 300 network

Step 6. Definition of Alarm handling

Step 7. Definition of OM Access

Step 8. Dump and Reload of System Data / Configuration Data

Diamux Training A/S


CURSO DE DIAMUX

Synchronisation
x

Clock and Tone Unit

Clock extraction

ALT

ALT
CTU
SYNC
MUX *Generate 2MHz for the exchange extracted from
1 of 4 incoming PCM (or from itself, MASTER)
ALT

*Generate 8 MHz for the CSB


PSB and ALT.
ALT

*Create Tones for the subscriber handling.

Diamux Training A/S


CURSO DE DIAMUX

CTU as Clock Master

Local Exchange
MUX3

UAD=201
ALT997
UAD=401
d5 ALT999

d5
UAD=200
ALT997 UAD=401
ALT997
MUX1 UAD=201
ALT999
MUX2
d5
UAD=400 UAD=200
UAD=402 ALT495 ALT495
ALT997 d5

Diamux Training A/S


CURSO DE DIAMUX

Tasks during Configuration of the Diamux


Step 1. Definition of Vital Element Data

Step 2. Down Line Load of Application software

Step 3. Definition of DCN / MTP signalling

Step 4. Configuration of Interfaces/Protocol

Step 5. Synchronisation in the Access 300 network

Step 6. Definition of Alarm handling

Step 7. Definition of OM Access

Step 8. Dump and Reload of System Data / Configuration Data

Diamux Training A/S


CURSO DE DIAMUX

Alarm Subscription

MUX1

Alarms to
AEM
Alarm
Subscription
System

All alarms
except Alert

Diamux Training A/S


CURSO DE DIAMUX

OM Access

The tables holds OM´s that is


allowed to operate the Diamux

OM Access Table
Local OM
OM Access Table

1 OM specified in VED
Local OM
1 OM specified in VED
2
3

2
3

Diamux Training A/S


CURSO DE DIAMUX

Power Supply Configuration

63V 68V DRG PSU098 DC/DC PSU097

IGM561/562 Ok Might Ok Ok Ok Ok
damage
hardware
IGM441/442 Ok Ok Not Ok Ok Ok Ok

AGM450/451 Ok Might Ok Ok Ok Ok
damage
hardware
AGM460/461 Might Ok Not Ok Ok Ok Ok
damage
hardware

Diamux Training A/S


CURSO DE DIAMUX

Safety copy for the basic configuration

SHU / MSU Network Element DSU568 / DSU576 Diax OM


Protected Area
Remote Dump
Command Local Dump
Log Area OM
Remote Load

ON
Vital O FF
Element
Data
New Element
Data SYS-RESSW Local Dump
Harddisk

1
Command Log 2
Restart without Local Dump + 3
Workdata Area
4
Local Dump Area
5
(Element Data) =
Element Data

VED-RD: Diax; {Read VED} SYS-RESSW : Diax, Active ; {Restart Software} SYS-RDDF: OM, Diax ; {Read Dumpfiles}
SYS-DULE : Diax ; {Local Dump}
SYS-DURE : Diax, filename ; {Remote Dump}
SYS-LDRE : Diax, filename ; {Remote Load}

Diamux Training A/S


CURSO DE DIAMUX

AEM
1
Presentation
(Access Element Manager)

of
NMAccess
2 (Network Management System for
Access)
Management
System
Tasks during installation
Subscribers &
3
Configuration

Diamux Training A/S


CURSO DE DIAMUX

NMAccess architecture
NMA Information
OMII OMII NMA NMA Line Mediation
System SAPS Mapping
GUI MMLCM FM Net Eng Net Op Test Servers
config Layer
applications
(Clients)

API API API


NMA NMA NMA NMA NMA NMA NMA NMA Line
Route Route Fault Timed Statistics Performance Traffic Load Network Test ASC
Determination Construction Management circuits Management Management Management Synchronizer Server

Servers

MML API FM API ODBC

NT domain
OM II Server SQL Server
Controller

ALC Graph
PCS7 View
TCP/IP MIB DB

Diamux Training A/S


CURSO DE DIAMUX

Management System Architecture

Clients LAN Servers


(Workstations) Diamux
OM II server

AEM Client

NMAccess
server(s)
NMAccess
Client

Database
server
AEM Client

Windows NT
 Client / server based distributed
Domain server computer environment
SQL  SQL database
 Scaleable

Diamux Training A/S


CURSO DE DIAMUX

Features and Clients in NMAccess

 NMAccess - Network Engineering


Graphical configuration / Drawing of the Access 300 network
 NMAccess - Network Operation
Setting Up Services
 NMAccess - Fault Management (Listing in text)
 NMAccess - Fault Management (Graphical )
 Data Gathering and Reporting
 Line Test Measurements.
 Inconsistency Checker.
 Network Trawler
 Network Clean Up

Diamux Training A/S


CURSO DE DIAMUX

NTU 560 configuration

MUX1

NTA10

NTU560

Diamux Training A/S


CURSO DE DIAMUX

DSU load and restart

Diamux Training A/S


CURSO DE DIAMUX

Supported interface protocols


Aggregate Interfaces
A940Agt Inverse PSTN Tributary Interfaces
Telephone Line Termination A415Tbt PSTN Telephone Line
I441Agt Inverse ISDN Termination
U-interface Termination A450Tbt PSTN Telephone Line
I561Agt Inverse ISDN Termination
U-interface Termination A460Tbt PSTN Telephone Line
RsmAgt Ericsson PSTN protocol Termination

D51Agt Diax Proprietary Protocol I441Tbt ISDN U-interface Termination


for PSTN, ISDN and O&M I561Tbt ISDN U-interface Termination
Q931Agt PRA Proprietary Protocol ESMTbt Ericsson PSTN protocol e.g.
used for connecting RAS1000
McasAgt Mecury Proprietary CAS and DRA1900 to the Access
protocol network.
V51Agt V5.1 Protocol D51Tbt Diax Proprietary Protocol
V52SLAgt V5.2 Single Link Protocol for PSTN, ISDN and O&M

V52Agt V5.2 Multi Link Protocol D52Tbt Diax Proprietary Protocol


for PSTN, ISDN and O&M
DLC96Agt Protocol terminating T1 with PSTN concentration
interfaces
D52Agt Diax Proprietary Protocol
for PSTN, ISDN and O&M
with PSTN concentration
Hotline PSTN-hotline protocol

Diamux Training A/S


CURSO DE DIAMUX

E1 link configuration

MUX1 MUX2

Diamux Training A/S


CURSO DE DIAMUX

E1 link configuration

MUX1 MUX2

Diamux Training A/S


CURSO DE DIAMUX

E1 half link configuration

MUX1 MUX2

Diamux Training A/S


CURSO DE DIAMUX

PCM configuration

Diamux Training A/S


CURSO DE DIAMUX

Multiple link configuration

V52 D52

Diamux Training A/S


CURSO DE DIAMUX

E2 configuration

Diamux Training A/S


CURSO DE DIAMUX

NMAccess - Network Engineering.

Diamux Training A/S


CURSO DE DIAMUX

Best practice design

• As few panels as possible…


• As few icons as possible…
• 2 closely related nodes in one panel if possible…
• One node shared by many nodes in its own panel…
• Avoid having E1 and half links on top of each other…
• Avoid excessive use of crossing sections...

Diamux Training A/S


CURSO DE DIAMUX

Worst practice design example

Diamux Training A/S


CURSO DE DIAMUX

NMAccess Network Engineering client

Diamux Training A/S


CURSO DE DIAMUX

Network Engineering toolbox

Diamux Training A/S


CURSO DE DIAMUX

Views of a network

Diamux Training A/S


CURSO DE DIAMUX

NMAccess graphical inventory

Diamux Training A/S


CURSO DE DIAMUX

NMAccess - Network Operation

Diamux Training A/S


CURSO DE DIAMUX

Network element configuration

Diamux Training A/S


CURSO DE DIAMUX

Diamux Training A/S


CURSO DE DIAMUX

Diamux Training A/S


CURSO DE DIAMUX
Diamux 120 CAD1 115KV
Diamux 500 CAD1 115KV
CAD1 115KV Diamux 500 Casa de Mandos
Casa de Mandos
Casa de Mandos S/E Cerro Negro
S/E Palital
S/E Furrial
CAD2 115KV

CAD2 115KV CAD2 115KV


CAD2 115KV
Diamux 120
S/E Morichal
Diamux 500
CAD3 115KV Casa de Mandos CAD1 400KV
CAD1 400KV
S/E Jose
CAD2 400KV CAD2 400KV
Diamux 500
Sala de MUX Diamux 500
CAD4 115KV Puerto Ordaz Casa de Mandos
S/E El Callao

CAD5 115KV CAD2 400KV

Diamux 500
CAD1 400KV Diamux 500
Casa de Mandos
Casa de Mandos
S/E Las Claritas
Diamux 500 S/E Macagua II
CAD1 400KV
Casa de Mandos
S/E San Geronimo Diamux 500
Casa de Mandos
S/E Santa Elena CAD1 230KV

CAD1 230KV

Diamux Training A/S


CURSO DE DIAMUX

Final
Presentado por:
Harry Galdón

Diamux Training A/S