Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Datos Iniciales
𝑃
Altura de relleno sobre el talón H= 8.00 m ℎ = 1.65 m 0.825
0.825
𝑒
Carga muerta PDC = 37.50 Ton/m 𝑁
𝑒
Carga de Asfalto PDW = 2.00 Ton/m 𝑡 𝑡
I. Pre-dimensionamiento
Considerando: Longitud del puente: L= 18.00 m Altura media del pilar intermedio H' = 0.00 mm
𝑡 −𝑡
Desviación del apoyo 𝑆° = 𝑎𝑡𝑎𝑛 S° = 0.00 °
𝐻 − ℎ −𝑒 − 𝑒 −𝐷
𝐵𝑅
𝐸𝐻
𝑃 6
𝟏𝟏
4.00 𝐸𝑉
2.67 0.90 𝟏𝟐
𝑌
2.80 1.50 3.00
1.00 7
A
𝑝 p′ 𝑝′
𝐵= 5.20 m
2.1.1 Cargas DC
Volumen DC XA YA XA * DC YA * DC
Elemento
(m3) (Ton/m) (m) (m) (Ton-m/m) (Ton-m/m)
1 0.66 1.584 2.200 7.175 3.48 11.37
2 0.000 0.000 1.950 6.35 0.00 0.00
3 0 0.000 2.400 6.35 0.00 0.00
4 4.815 11.556 1.950 3.68 22.53 42.47
5 0.000 0.000 1.500 6.35 0.00 0.00
6 0.000 0.000 1.500 2.783 0.00 0.00
7 5.200 12.480 2.600 0.500 32.45 6.24
Σ= 25.620 58.47 60.07
2.1.2 Cargas DW
Volumen EV XA YA XA * DC YA * DC
Elemento
(m3) (Ton/m) (m) (m) (Ton-m/m) (Ton-m/m)
8 19.6 33.320 3.800 4.500 126.62 149.94
9 0.000 0.000 2.400 6.350 0.00 0.00
10 0 0.000 2.400 3.675 0.00 0.00
11 0.000 0.000 1.500 2.333 0.00 0.00
12 3.000 5.100 0.750 2.000 3.83 10.20
Σ= 38.420 130.44 160.14
2.1.4 Cargas LL + IM
Por cargas vehiculares actuando sobre el terreno, agregamos una porción equivalente de suelo.
En este caso para H =8 m, h' = 0.2 m.
𝑠𝑒𝑛 Φ + 𝛿 𝑠𝑒𝑛(Φ − β)
𝑟 = 1+ r= 3.370515
𝑠𝑒𝑛 Ɵ − 𝛿 𝑠𝑒𝑛(Ɵ + β)
𝑠𝑒𝑛 Ɵ + Φ
𝑘 = ka = 0.231013
𝑟(𝑠𝑒𝑛 Ɵ 𝑠𝑒𝑛(Ɵ − δ))
cargas actuantes:
YA = 4.00 m
YA = 2.67 m
𝑐𝑜𝑠 Φ − Ɵ − β′
𝑘 = = 0.379631
𝑠𝑒𝑛 Φ + 𝛿 𝑠𝑒𝑛(Φ − Ɵ − ἱ)
𝑐𝑜𝑠Ɵ 𝑐𝑜𝑠 β cos(δ + β + Ɵ ) 1 +
𝑐𝑜𝑠 𝛿 + β + Ɵ′ 𝑐𝑜𝑠(ἱ − β′)
Entonces:
- Efecto combinado de P AE y P IR
• PAE + 0.5PIR = 26.99191 Ton/m > • (0.5PAE > EH) + PIR = 25.25 Ton/m
Consideramos entonces la expresión: 26.9919 Ton/m por simple inspección es crítica tanto en
carga como en momento. Al valor de P AE le descontamos la presión estática del terreno (EH) para tratarla por separado, utilizando en
las combinaciones de carga.
El Art. 3.10.9.1 AASHTO LRFD establece para los puentes de un solo tramo, independientemente de la zona sísmica en que se
encuentren, una solicitación mínima de diseño en una unión restringida entre superestructura y subestructura no menor al producto del
coeficiente de aceleración As y la carga permanente tributaria, es decir:
- Carga BR (frenado)
BR = 2 Ton/m YA = 9.80 m
Para el chequeo de estabilidad al vuelco y deslizamiento observando en el gráfico las cargas actuantes, utilizamos los factores γ
máximos para las cargas horizontales (desestabilizadoras) que generan vuelco alrededor del punto A y deslizamiento en la base (LSx,
EH, WQ y BR) y los factores de carga γ mínimos en las cargas verticales que generan estabilidad (DC, DW, EV, LL+IM, LSy) para de esta
manera máximizar las condiciones críticas de vuelco y deslizamiento en la estructura. Este caso será denominado Resistencia Ia.
Para el chequeo de presiones en la base empleamos los factores γ máximos en cargas verticales y horizontales para maximizar la
presión sobre el terreno. A este caso lo denominaremos resistencia Ib.
Para el chequeo de estabilidad al vuelco, deslizamiento y presiones también aplicamos el estado límite de evento extremo I con los
coeficientes señalados en la Tabla 3.4.1-1 (ó la Fig. C11.5.6-4), AASHTO LRFD.
El chequeo de agrietamiento por distribución de armadura en la pantalla se realizará para el estado límite de Servicio I.
ESTADO LÍMITE γDC γDW γEV γ LL+IM γLSy γLSx γEH γEQ γBR Aplicación
Deslizamient
0.90 0.65 1.00 - - 1.75 1.50 - 1.75
Resistencia Ia o y vuelco
1.25 1.50 1.35 1.75 1.75 1.75 1.50 - 1.75 Presiones
Resistencia Ib
Deslizam.,
1.00 1.00 1.00 0.50 0.50 0.50 1.00 1.00 0.50
Ev. Extremo I vuelco y
Agrietamien
Servicio I 1.00 1.00 1.00 1.00 1.00 1.00 1.00 - 1.00 to
TIPO DC DW EV LL+IM LS Σ=
CARGA DC PDC PDW EV PLL+IM LSy Vu (Ton)
V(Ton) = 25.62 37.50 2.00 38.42 42.05 0.95 146.54
γ= 0.90 0.90 0.65 1.00 0 0
Resistencia Ia 23.058 33.75 1.3 38.42 0 0 96.53
γ= 1.25 1.25 1.50 1.35 1.75 1.75
Resistencia Ib 32.025 46.875 3 51.867 73.5875 1.666 209.02
γ= 1.00 1.00 1.00 1.00 0.50 0.50
Ev. Extremo I 25.62 37.50 2.00 38.42 21.03 0.48 125.04
γ= 1.00 1.00 1.00 1.00 1.00 1.00
Servicio I 25.62 37.50 2.00 38.42 42.05 0.95 146.54
TIPO DC DW EV LL+IM LS Σ=
CARGA DC PDC PDW EV PLL+IM LSy Mu (Ton)
Mv (Ton-m) = 58.47 65.63 3.50 130.44 73.59 3.62 335.24
γ= 0.90 0.90 0.65 1.00 0 0
Resistencia Ia 52.62 59.06 2.28 130.44 0.00 0.00 244.40
γ= 1.25 1.25 1.50 1.35 1.75 1.75
Resistencia Ib 73.08375 82.03125 5.25 176.095 128.7781 6.3308 471.57
γ= 1.00 1.00 1.00 1.00 0.50 0.50
Ev. Extremo I 58.47 65.63 3.50 130.44 36.79 1.81 296.64
γ= 1.00 1.00 1.00 1.00 1.00 1.00
Servicio I 58.47 65.63 3.50 130.44 73.59 3.62 335.24
TIPO LS EH EQ BR Σ=
CARGA LSx EH EQterr 0.5PIR PEQ BR Hu (Ton)
H(Ton) = 0.63 12.57 8.08 6.34 15.64 2.00 45.26
γ= 1.75 1.50 0 0 0 1.75
Resistencia Ia 1.10 18.85 0.00 0.00 0.00 3.50 23.45
γ= 1.75 1.50 0 0 0 1.75
Resistencia Ib 1.10 18.85 0.00 0.00 0.00 3.50 23.45
γ= 0.50 1.00 1.00 1.00 1.00 0.50
Ev. Extremo I 0.31 12.57 8.08 6.34 15.64 1.00 43.95
γ= 1.00 1.00 0 0 0 1.00
Servicio I 0.63 12.57 0.00 0.00 0.00 2.00 15.20
TIPO LS EH EQ BR Σ=
CARGA LSx EH EQterr 0.5PIR PEQ BR MHu (Ton-m)
MH(Ton) = 2.51 33.51 32.34 21.80 112.23 19.60 222.00
γ= 1.75 1.50 0 0 0 1.75
Resistencia Ia 4.40 50.27 0.00 0.00 0.00 34.30 88.97
γ= 1.75 1.50 0 0 0 1.75
Resistencia Ib 4.40 50.27 0.00 0.00 0.00 34.30 88.97
γ= 0.50 1.00 1.00 1.00 1.00 0.50
Ev. Extremo I 1.26 33.51 32.34 21.80 112.23 9.80 210.94
γ= 1.00 1.00 0 0 0 1.00
Servicio I 2.51 33.51 0.00 0.00 0.00 19.60 55.63
Se debe mantener la resultante en la base del cimiento dentro de los dos tercios centrales (e≤B/3), excepto el caso de
suelo rocoso en que se mantendrá en los 9/10 centrales (e≤0.45B).
Cuando γEQ = 0, se debe mantener la resultante en la base del cimiento dentro de los 2/3 centrales del cimiento para
cualquier suelo (e≤B/3).
Cuando γEQ = 1, se debe mantener la resultante en la base dentro de los 8/10 centrales del cimiento para cualquier suelo
(e≤2/5B).
Para los valores γEQ entre 0 y 1.0, interpolar linealmente entre los valores especificados. En nuestro caso, utilizando γ EQ =
0.5, la interpolación señala el límite e≤(11/30)B.
𝑀 −𝑀 𝐵
Vu MVu MHu 𝑋 = 𝑒= −𝑋 emax
Estado 𝑉 2
qR = øb qn (10.6.3.1.1-1)
2
qR = øb (FS.qadm) qR = 8.25 kg/cm
qR = øb qn (10.6.3.1.1-1)
2
qR = øb (FS.qadm) qR = 12.00 kg/cm
2
- Estado límite de servicio: qadm = 5.00 kg/cm
𝑀 −𝑀 𝐵 𝑉
Vu MVu MHu 𝑋 = 𝑒=
2
−𝑋 𝑞=
Estado 𝑉 𝐵 − 2𝑒
(Ton/m) (Ton-m/m) (Ton-m/m) (m) (m) (kg/cm 2)
Resistencia Ia 96.53 244.40 88.97 1.61 0.99 3.00 < 8.25 OK!
Resistencia Ib 209.02 471.57 88.97 1.83 0.77 5.71 < 8.25 OK!
Evento Extremo I 125.04 296.64 210.94 0.69 1.91 9.12 < 12.00 OK!
Servicio I 146.54 335.24 55.63 1.91 0.69 3.84 < 5.00 OK!
TIPO DC EV LS Σ=
CARGA DC EV LSy Vu (Ton)
V(Ton) = 25.62 38.42 0.95 64.99
γ= 0.9 1 0
Resistencia Ia 23.058 38.42 0 61.48
γ= 1.25 1.35 1.75
Resistencia Ib 32.025 51.867 1.666 85.56
γ= 1 1 0.5
Ev. Extremo I 25.62 38.42 0.48 64.52
γ= 1 1 1
Servicio I 25.62 38.42 0.95 64.99
TIPO DC EV LS Σ=
CARGA DC EV LSy Mvu (Ton)
Mv (Ton-m) = 58.47 130.44 3.62 192.53
γ= 0.9 1 0
Resistencia Ia 52.62 130.44 0.00 183.06
γ= 1.25 1.35 1.75
Resistencia Ib 73.08 176.10 6.33 255.51
γ= 1 1 0.5
Ev. Extremo I 58.47 130.44 1.81 190.72
γ= 1 1 1
Servicio I 58.47 130.44 3.62 192.53
TIPO LS EH EQ Σ=
CARGA LSx EH Eqterr 0.5PIR Hu (Ton)
H (Ton-m) = 0.63 12.57 8.08 6.34 27.62
γ= 1.75 1.5 0 0
Resistencia Ia 1.10 18.85 0.00 0.00 19.95
γ= 1.75 1.5 0 0
Resistencia Ib 1.10 18.85 0.00 0.00 19.95
γ= 0.5 1 1 1
Ev. Extremo I 0.31 12.57 8.08 6.34 27.31
γ= 1 1 0 0
Servicio I 0.63 12.57 0.00 0.00 13.20
TIPO LS EH EQ Σ=
CARGA LSx EH Eqterr 0.5PIR MHu (Ton-m)
MH (Ton-m) = 2.51 33.51 32.34 21.80 90.17
γ= 1.75 1.5 0 0
Resistencia Ia 4.40 50.27 0.00 0.00 54.67
γ= 1.75 1.5 0 0
Resistencia Ib 4.40 50.27 0.00 0.00 54.67
γ= 0.5 1 1 1
Ev. Extremo I 1.26 33.51 32.34 21.80 88.91
γ= 1 1 0 0
Servicio I 2.51 33.51 0.00 0.00 36.03
𝐵
Vu MVu MHu 𝑋 = 𝑀 −𝑀
𝑒= −𝑋 emax =B/3
Estado 𝑉 2
(Ton/m) (Ton-m/m) (Ton-m/m) (m) (m) (m)
Resistencia Ia 61.48 183.06 54.67 2.09 0.51 1.73 OK!
Resistencia Ib 85.56 255.51 54.67 2.35 0.25 1.73 OK!
Evento Extremo I 64.52 190.72 88.91 1.58 1.02 1.91 OK!
Añadir diente de concreto armado en la base del estribo solo si se indica NO SATISFACTORIO!
b die = - m
3.00
2
15.005 Ton/m
0.00
2
0.00 15.005 Ton/m
Para el estado límite de Resistencia aplicamos el método estático proveído en 3.11.5.4 y Fig. 3.11.5.4-1 de las especificaciones AASHTO.
El coeficiente de empuje pasivo para:
øf = 37° y Ɵ= 90° ==> k'p = 6.30
𝑀 −𝑀 𝐵 𝑉
Vu MVu MHu 𝑋 = 𝑒= −𝑋 𝑞=
Estado 𝑉 2 𝐵 − 2𝑒
(Ton/m) (Ton-m/m) (Ton-m/m) (m) (m) (kg/cm 2)
Resistencia Ia 61.48 183.06 54.67 2.09 0.51 1.47 < 8.25 OK!
Resistencia Ib 85.56 255.51 54.67 2.35 0.25 1.82 < 8.25 OK!
Evento Extremo I 64.52 190.72 88.91 1.58 1.02 2.04 < 12.00 OK!
Servicio I 64.99 192.53 36.03 2.41 0.19 1.35 < 5.00 OK!
𝐸𝑄 𝐿𝑆
7.00
𝑃
𝐸𝐻
3.5 YP= 3.10
2.33
𝑝 p′ 𝑝′ P
Para el diseño estructural PIR sin incluir la masa del suelo sobre el talón (C 11.6.5.1)
• PAE + 0.5PIR = 17.11251 Ton/m > • (0.5PAE > EH) + PIR = 12.22 Ton/m
Consideramos entonces la expresión: 17.1125 Ton/m por simple inspección es crítica tanto en
carga como en momento. Al valor de P AE le descontamos la presión estática del terreno (EH) para tratarla por separado, utilizando en
AE
las combinaciones de carga.
Mu = 67.84351114 Ton-m
• As diseño
Recubrimiento: r= 5.00 cm Ancho a analizar: b= 1.00 m
• As máximo
Las actuales disposiciones AASHTO LRFD eliminan este límite.
• As mínimo
Las cantidades de acero proporcionado debe ser capaz de resistir el menor valor de Mcr y 1.33Mu
𝐴 =
.
𝑐𝑚 /m (5.10.6-1) Astemp = 6.9336 cm2/m en cada cara
( )
2 2 2
2.33 cm /m < 6.9336 cm /m < 12.70 cm /m
Usando la sección agrietada y una franja de 0.11 m de ancho, para el diseño por estado límite de
Servicio I, con n = nD nR nI = 1
Ms = 41.97 Ton-m/m
Para un ancho tributario de : 0.11 m 90 cm
11 cm
4.1.3.2 Ubicación del eje netro:
Típicamente el corte no gobierna el diseño de un muro de contención; sin embargo revisaremos el grosor de la pantalla para confirmar
que no se requiere armadura transversal. Por simplicidad tomaremos la sección crítica en la base de la pantalla aunque puede ser
tomada a una distancia igual al peralte efectivo desde la base.
Vu = 18.89470593 Ton
El cortante actuante en la base de la pantalla para el estado límite de Evento Extremo I, con
n = nD nR nI = 1
Vu = 34.03 Ton
Tomamos Vu = 34.03 Ton
Vp = 0 Vs = 0
Vn = Vc + Vs + Vp (5.7.3.3-1) Vn = 63.06 Ton
Vn = 0.25f 'c bv dv + Vp (5.7.3.3-2) Vn = 557.583 Ton
Cálculo de β = 1.785295513
Como lpant = 7.00 m > 0.40 m No es aplicable el procedimiento simplificado 5.7.3.4.2
4.8 39
β= (5.7.3.4.2-2) β= 1.79
(1 + 750ε ) (39 + 𝑠 )
│𝑀 │ εs =
+ │𝑉 │ (5.7.3.4.2-4) 0.00127
𝑑
ε =
𝐸𝐴
siendo:
Sx = d v = 79.65 cm = 31.3601 "
ag = tamaño máximo del agregado = 3/4 "
Momento de diseño en cara vertical de pantalla, estado límite de Resistencia Ib, con
n = nD nR nI = 1 , Despreciando del lado conservador la reacción del suelo:
Mu = 77.07 Ton-m/m
ℎ′ = 0.20 𝐿𝑆 = 0.95 T
1.65
0.00
1.4
7.00 𝐸𝑉 = 33.32 T
1.40
2.80 0
𝐷𝐶 = 6.72 T
𝐴𝑠 𝑠𝑢𝑝𝑒𝑟𝑖𝑜𝑟
1.00 𝑇𝑎𝑙ó𝑛 𝑆𝑒𝑐𝑐𝑖ó𝑛 𝑐𝑟í𝑡𝑖𝑐𝑎
𝐴𝑠 𝑠𝑢𝑝𝑒𝑟𝑖𝑜𝑟
1.00 𝑇𝑎𝑙ó𝑛 𝑆𝑒𝑐𝑐𝑖ó𝑛 𝑐𝑟í𝑡𝑖𝑐𝑎
𝑞
𝑞
𝐵= 5.20
• As diseño
Recubrimiento: r= 5.00 cm Ancho a analizar: b= 1.00 m
2
0.59* w - w + Mu w1 = 1.6594 𝜌 = w * f 'c/fy
0.90 f 'c * b * d2 w2 = 0.0356 As = 𝜌 * b * d
• As máximo
Las actuales disposiciones AASHTO LRFD eliminan este límite.
Vu = 55.048 Ton
El cortante actuante en la base de la pantalla para el estado límite de Evento Extremo I, con
Vp = 0 Vs = 0
Cálculo de β = 0.987231144
Como ltalón = 2.80 m > 2.75 m No es aplicable el procedimiento simplificado 5.7.3.4.1
siendo:
Sx = d v = 91.77 cm = 36.1298 "
ag = tamaño máximo del agregado = 3/4 "
𝑐𝑜𝑟𝑡𝑒
𝑑 = 0.89 m
𝑓𝑙𝑒𝑥𝑖ó𝑛
𝐸𝑉
𝐴𝑠 𝑝𝑎𝑟𝑡𝑒 𝑖𝑛𝑓𝑒𝑟𝑖𝑜𝑟 𝑧𝑎𝑝𝑎𝑡𝑎
𝐷𝐶
𝑇𝑎𝑙ó𝑛
Z 𝑞 =
, 67.513 Ton/m
𝑞 , = 4.504 Ton/m
𝑞 , = 75.888 Ton/m
𝑞 , = 55.296617 Ton/m
𝐵= 5.20 m
𝐿 = 1.50 m
Cargas actuantes en la punta del estribo
Para el diseño estructural del cimiento cargado excéntricamente se considera utilizando cargas factoradas, sea el suelo rocoso o no
rocoso, una distribución de esfuerzos de contacto triangular o trapezoidal (Art. 10.6.5).
Siendo crítico el estado límite de Resistencia Ib, con Vu = 209.02 T y e = 0.77 m (Ver tabla
de presiones actuantes en la base del estribo), calculamos las presiones sobre el terreno:
𝑉 6
𝑞 = 1± q1,u = 75.888 Ton/m q2,u = 4.50447 Ton/m
𝐵 𝐵
Despreciando del lado conservador el peso del terreno (EV) y de la punta de zapata (DC), el momento actuante en la sección crítica por
flexión es:
𝐿
𝑀 =
6
𝑞 , + 2𝑞 , Mu = 77.65 Ton-m
• As diseño
Recubrimiento: r= 7.50 cm Ancho a analizar: b= 1.00 m
2
0.59* w - w + Mu w1 = 1.657 𝜌 = w * f 'c/fy
0.90 f 'c * b * d2 w2 = 0.0379 As = 𝜌 * b * d
As = 5.07 M (Tn-m) b (cm) d(cm) ρ As diseño (cm2) Ø Disposición
db Ø = 2.54 77.652 100 91.23 0.00252 23.03 Ø 1" Ø 1" @ 0.22 m
• As máximo
Las actuales disposiciones AASHTO LRFD eliminan este límite.
𝐴 𝑓 𝑎
𝑎= = 4.470948 cm 𝑀 =ø𝑓 𝐴 𝑑− = 85.23 Ton-m
0.85𝑓′ 𝑏 2
Ver. Rediseño: Mu = 85.23 Ton-m > 61.662 Ton-m OK As resiste!
Debiendo tomar el cortante actuante a una distancia dv de la cara de la pantalla, el cortante actuante es:
Vp = 0 Vs = 0
Cálculo de β = 2
Como lpunta = 1.50 m < 2.67 m Es aplicable el procedimiento simplificado 5.7.3.4.1
Ø 1" @ 0.11 m
Ø 3/4" @ 0.41 m
Ø 3/4" @ 0.41 m