Documentos de Académico
Documentos de Profesional
Documentos de Cultura
DATOS:
Volumen del tanque elevado= 3000 l
Tiempo de llenado= 1 hora
Caudal de bombeo= 0.83 l/s
0.00083 m3/s
Viscosidad del agua= 1.01E-06 m2/s
Rugosidad de la tuberia= 0.0015 mm
PÉRDIDAS EN LA SUCCIÓN
PÉRDIDAS EN LA IMPULSIÓN
Altura dinamica
Caudal Q
total H
l/s m GRAFICAR LA CURVA DEL SISTEMA
0.00 12.00 Ht=hs+hi+∑ht (succion)+∑ht (impulsion)
0.10 12.02
0.20 12.06
0.30 12.12
0.40 12.21
0.50 12.32
0.60 12.45
0.70 12.60
0.80 12.77
0.90 12.96
1.00 13.18
1.10 13.40
1.20 13.67
1.30 13.96
1.40 14.23
1.50 14.56
DIAMETRO ESPESOR DE
NOMENCLATURA EXTERIOR PARED DIAMETRO
NOMINAL NOMINAL NOMINAL INTERIOR
ocidad asumida pulg mm mm mm
1/2" 21.25 3.73 13.79
metro calculado 3/4" 26.58 3.91 18.76
metro asumido 1" 33.3 4.55 24.2
1 1/4" 42.05 4.85 32.35
1 1/2" 48.12 5.1 37.92
metro interior seleccionado 2 60.3 5.6 49.1
ocidad asumida
metro calculado
metro asumido
Número de Reynolds
f hf K hm ht
Re=DV/v
m m m
0.000 0.000 0.000 15.60 0.000 0.000
3,332.592 0.043 0.009 15.60 0.006 0.015
6,668.949 0.035 0.030 15.60 0.025 0.055
10,001.541 0.031 0.059 15.60 0.056 0.115
13,337.899 0.029 0.098 15.60 0.100 0.198
16,670.491 0.027 0.142 15.60 0.156 0.298
20,006.848 0.026 0.197 15.60 0.224 0.421
23,339.440 0.025 0.258 15.60 0.305 0.563
26,675.797 0.024 0.324 15.60 0.399 0.723
30,008.389 0.023 0.393 15.60 0.505 0.898
33,344.747 0.023 0.485 15.60 0.623 1.108
36,677.339 0.022 0.561 15.60 0.754 1.315
40,013.696 0.022 0.668 15.60 0.898 1.566
43,346.288 0.022 0.784 15.60 1.054 1.838
46,682.645 0.021 0.868 15.60 1.222 2.090
50,015.237 0.021 0.996 15.60 1.403 2.399
RVA DEL SISTEMA
ion)+∑ht (impulsion)
19.00
15.00
13.00
11.00
9.00
-0.10 0.10 0.30 0.50 0.70 0.90 1.10
CAUDAL (l/s)
ACCESORIOS PARA CALCULO DE PÉRDIDAS MENORES
ACCESORIOS
SUCCIÓN No. Valor Total
VÁLVULA DE PIE 1 2.5
3.4
CODO 90 1 0.9
IMPULSIÓN No. Valor Total
TEE CON DERIVACIÓN 1 1.8
VÁLVULA CHECK O RETENCIÓN 1 10
15.6
VÁLVULA DE COMPUERTA 1 0.2
CODO 90 4 0.9
RVA DE LA BOMBA
Column C
ACm25
XHSm1500
XGm/1A
DAL (l/s)