Está en la página 1de 1

A B

B A
C
CONJUNTO RESIDENCIAL
2,40 2,28
.06 .06 RAFAEL NUÑEZ

2 2

.05
2 M.E.S. Ø7mm. C/.15 C/sent.
2 M.E.S. Ø7mm. C/.15 C/sent.
NIVEL 0.00
2 M.E.S. Ø7mm. C/.15 C/sent.

.10
.12 .12 .12 .12 .12
C C 2 M.E.S. Ø7mm. C/.15 C/sent.

.10
.10
VT-2 VT-2

.60

.10
VT-2
NIVEL - 0.60 VT-2 DISEÑOS Y SISTEMAS

.68
.56
VT-3

.44
.32
.30
INGENIEROS CIVILES
JUAN TAMASCO T.
AVENIDA 9 No. 123-20 TEL 6 126461 - FAX 2 135249
E-Mail ingenieria@disenosysistemas.com
.30 9,00

.05
1 1 1 1 2 2 1 1 CONTENIDO

CORTE B - B PLANTA RAMPAS


ESC.: 1:30
CORTES Y DETALLES
9,00

MATERIALES
CONCRETOS
MUROS - PANTALLAS F'c = 4.000 P.S.I.
CIMENTACION F'c = 4.000 P.S.I.
ZARPA ZARPA PILOTES F'c = 4.000 P.S.I.
.41 PILOTES COLUMNAS F'c = 4.000 P.S.I.
VER DET. 1 PLACAS F'c = 3.500 P.S.I.
REFUERZO: Fy = 60.000 P.S.I.
2 M.E.S. Ø7mm. C/.15 C/sent. CARGA VIVA
NIVEL 0.00 PARQUEADEROS = 250 Kg/m2
1ro y 2do PISO = 500 Kg/m2
RAMPA 3ro a 7mo PISO = 200 Kg/m2

.30
TERRAZA = 500 Kg/m2

.10
.60
ACERO ESTRUCTURA A-50

.30
VT-1 VT-1 Capacidad de disipacion de energia

.10
NIVEL - 0.60 - DMO
.70 .70

.30
VT-1 Coeficiente de disipacion de energia
- Ro = 6.00

.30
VT-1 Grupo de Uso I
MICROZONIFICACION SISMICA
.29 .29 1,70 .29 .29 1,58 .29 .29 LACUSTRE 100
.12 .12 .12 .30 9,00 MAXIMO POTENCIAL COMBUSTIBLE
350 MXJ/m2
.70 .05 NORMA NTC-2289 (ASTMA70 6M)
NORMA NSR-10 (REFUERZO CORRUGADO
1 2 - VARILLAS Y MALLA ELECTROSOLDADA)
C.21.1.5.2 TODO EL REFUERZO CORRUGADO
(C.3.5.3.1), QUE RESISTA FUERZAS AXIALES Y
1 1 CORTE A - A DE FLEXION INDUCIDAS POR SISMO EN
.30

ELEMENTOS DE PORTICOS, MUROS


ESC.: 1:30 ESTRUCTURALES Y VIGAS DE ACOPLE,
.35 .35 1,70 .35 .35 1,58 .35 .35 DEBEN CUMPLIR CON LAS DISPOSICIONES
DE NTC 2289 (ASTM A706M), GRADO 420 MPa.

2,40 2,28
.06 .06
B A NOMENCLATURA
N = Cantidad de varillas
A B C #
A = Diametro de la varilla en octavos
de pulgada
PLANTA CIMENTACIÓN 2 M.E.S. Ø7mm. C/.15 C/sent.
BC = Longitud de la varilla en decimetros
ESC.: 1:50 2 M.E.S. Ø7mm. C/.15 C/sent.

.12
NOTAS
ANTES DE FUNDIR
VT-1

Variable
- VERIFICAR MEDIDAS NIVELES Y
DETALLES CON PLANOS

.63
ARQUITECTONICOS .
- NO SE PERMITIRA NINGUN CAMBIO DE
.06 .06 .06 .06 .06 .06 DESPIECES, SUSTITUCION DE
DIAMETROS O LOCALIZACION DE
A B C

.15

.15
B A EMPALMES A MENOS QUE SEA
AUTORIZADO POR EL CALCULISTA.
2,40 2,28 MEJORAMIENTO DE SUELO .35 .35 - PREVEER TACHES PARA DETALLES
DE ACABADOS Y FACHADAS.
.06 .06 VER ESTUDIO DE SUELOS - CONSULTAR PLANOS E INSTALACIONES

.70

.70

.70
MECANICAS Y SANITARIAS.
NIVEL DE FUNDACIÓN
GANCHOS ESTANDAR
.05

.05

DEFINIDO Y APROBADO POR


2 2 INGENIERO DE SUELOS. # 2 - Ø 1/4" = .10 # 6 - Ø 3/4" = .30
.05

.05

VT - 2 # 3 - Ø 3/8" = .15 # 7 - Ø 7/8" = .35


.12
.12

# 4 - Ø 1/2" = .20 # 8 - Ø 1" = .40


# 5 - Ø 5/8" = .25
2,40 2,28
C C ESTE PLANO ES VALIDO PARA
.06 .06 CONSTRUCCION UNICAMENTE COMO
2,25
2,01

A B C COPIA HELIOGRAFICA DEL ORIGINAL


2,76

IMPRESO POR EL DISEÑADOR.


PLACA MACIZA
E=.10
CORTE C - C
.12

VT - 2
ESC.: 1:30
CONVENCIONES
PLACA MACIZA = Armar en este sentido
E=.10 Corr. = Refuerzo corrido
.12

VT - 1 D.O.P. = Doblar en obra en planta


F.O. = Figurar en obra
F.E. = Fuera de escala
2,13

R.M.
2,25

= Recortar mecanicamente
PL = Platina
PC = Platina de Continuidad
2,28 1,02 1,02 T.A.M. = Traslapo alternado mínimo
.06 .06 .06 .06 .12 .06 .06
CERRAR CERRAR
# 3 = 0.40 # 4 = 0.50 # 5 = 0.60 # 6 = 0.70
.12

VT - 2 GANCHOS 2 M.E.S. Ø7mm. C/.15 C/sent. GANCHOS 2 M.E.S. Ø7mm. C/.15 C/sent.
VT - 1

2,88

2#4 CERRAR 2#4


9,00

9,00

GANCHOS
CERRAR CERRAR MODIFICACIONES

.10

.10
GANCHOS GANCHOS
.11 .11
2 # 4 Corr. FECHA OBJETO
T.A.M.= .50 .11
2 # 4 Corr. 2 # 4 Corr.

.42
T.A.M.= .50

Variable

Variable
.32
.22
2,13

.11 .17 .11


2 # 4 Corr.
2,25

.30

.22

Variable

Variable
.12

VT - 1 2 # 4 Corr. .07 2 # 4 Corr.


T.A.M.= .50 .07 T.A.M.= .50 .07
.12 E # 307 C/.20
.12 2 # 4 C.20 .12 2 # 4 C.20
E # 308 C/.20 E # 310 C/.20
.12

VT - 2
REFUERZO VT-1 REFUERZO VT-2 REFUERZO VT-3

.15

.15
ESC.: 1:20 ESC.: 1:20 .07 ESC.: 1:20 .07
.70 ó .90 E # 3 C/.20 .41
E # 3 C/.20
2,88

.09 .22 .09


.10 E # 3 C/.20 .10
2,13

E # 304 C/.20 Calculó :


2,25

J. T. T.
.60 ó .80

Dibujó :
REFUERZO CORTE 2-2 L.E.G.A.
REFUERZO CORTE 1-1 ESC.: 1:20
Archivo :
ESC.: 1:20
.12
.12

VT - 3 VT - 1
1 ARRANCA RAMPA
1 Fecha :
JUNIO / 2023

2,34 2,22 Escala :


INDICADAS
.06 .06 .06 .06
2,40 2,28 Firma :

.06 .06
B A
REFUERZO VT NOTA PROCESO CONSTRUCTIVO

A B C LAS COTAS Y NIVELES DE ESTOS PLANOS SON VÁLIDOS ÚNICAMENTE PARA DIMENSIONAMIENTO DE ELEMENTOS MATRICULA Nº
25202-00986
ESTRUCTURALES , LA LOCALIZACIÓN GENERAL, ACOTAMIENTO Y NIVELES SE EFECTUARAN SEGÚN PROYECTO
Variable
ARQUITECTÓNICO .
PLANTA LOS PLANOS ESTRUCTURALES DE ESTE PROYECTO HACEN PARTE COMO UN TODO DE LA SOLUCION ESTRUCTURAL
ESC.: 1:50 PLANTEADA POR EL DISEÑADOR PARA ESTA EDIFICACION EN PARTICULAR . VALIDO CONSTRUCTIVO
PLANO PARA REVISION
1:50
GANCHO STANDAR PARA SU CORRECTA INTERPRETACION DURANTE LA ETAPA CONSTRUCTIVA DEBERAN SER ESTUDIADOS COMO UN
CONJUNTO DEBIDO A LA EVIDENTE INTERDEPENDENCIA DE TODOS LOS PLANOS ENTRE SI.
POR LO TANTO SE DEBERA EVITAR EL USO DE PLANOS O PARTES DE PLANOS DE MANERA INDEPENDIENTE E INCONEXA, PLANO :
DETALLE RAMPA RT-4 LO CUAL FACILITA LA INTERPRETACION ERRONEA DE LOS MISMOS.

ER-06
DETALLE REMATE REFUERZO VT SE EXIGE LA EXISTENCIA EN EL SITIO DE EJECUCION DE LOS TRABAJO DE LOS ELEMENTOS ESTRUCTURALES DE UNA
ESC.: 1:50 ESC: 1 : 20 COPIA IMPRESA DE LA TOTALIDAD DE LOS PLANOS ESTRUCTURALES , NO SE DEBERAN EFECTUAR ESTOS TRABAJOS
CON PARTES DE LOS PLANOS IMPRESAS O EN MEDIOS ELECTRONICOS DEBIDO A LA ALTA POSIBILIDAD DE OCURRENCIA
DE GRAVES ERRORES EN EL ARMADO O EL DIMENSIONAMIENTO DE LOS ELEMENTOS ESTRUCTURALES , LO ANTERIOR
ES RESPONSABILIDAD DIRECTA DEL CONSTRUCTOR Y DE LA SUPERVISION TECNICA.

También podría gustarte