Nombre Tipo de datos Valor predet. Comentario
Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant
Segmento 1:
%DB1
"T1"
%M0.1 TON
"Interruptor_1" "T1".Q Time
IN Q
T#50s PT ET T#0ms
Segmento 2:
%Q0.2
"T1".ET "T1".ET "Motor_1"
>= <
Time Time
T#5s T#10s
"T1".ET "T1".ET
>= <
Time Time
T#30s T#50s
%Q0.3
"T1".ET "T1".ET
"Motor_2"
>= <
Time Time
T#5s T#15s
"T1".ET "T1".ET
>= <
Time Time
T#35s T#50s
%Q0.4
"T1".ET "T1".ET
"Motor_3"
>= <
Time Time
T#5s T#20s
"T1".ET "T1".ET
>= <
Time Time
T#40s T#50s
%Q0.5
"T1".ET "T1".ET "Motor_4"
>= <
Time Time
T#5s T#25s
"T1".ET "T1".ET
>= <
Time Time
T#45s T#50s
Segmento 3:
Totally Integrated
Automation Portal