Documentos de Académico
Documentos de Profesional
Documentos de Cultura
PVsyst TRIAL
PVsyst - Simulation report
Standalone system
PVsyst TRIAL
Santiago de Cotagaita - Bolivia
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: Colegio en Cotagaita
Variant: Nueva variante de simulación
PVsyst V7.4.2
VC0, Simulation date:
19/09/23 21:15
PVsyst TRIAL
with v7.4.2
Project summary
Geographical Site Situation Project settings
Santiago de Cotagaita Latitude -20.82 °S Albedo 0.20
Bolivia Longitude -65.66 °W
Altitude 2650 m
Time zone UTC-4
Meteo data
Santiago de Cotagaita
Meteonorm 8.1 (2009-2014), Sat=100% - Sintético
System summary
PVsyst TRIAL
Standalone system Standalone system with batteries
System information
PV Array Battery pack
Nb. of modules 210 units Technology Lithium-ion, LFP
Pnom total 69.3 kWp Nb. of units 10 units
Voltage 240 V
Capacity 2240 Ah
Results summary
PVsyst TRIAL
Useful energy from solar 95583 kWh/year
Missing Energy
Excess (unused)
0 kWh/year
46480 kWh/year
Table of contents
Solar Fraction SF
54.29 %
100.00 %
2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7
PVsyst TRIAL
PVsyst TRIAL
19/09/23 PVsyst Evaluation mode Page 2/7
Project: Colegio en Cotagaita
Variant: Nueva variante de simulación
PVsyst V7.4.2
VC0, Simulation date:
19/09/23 21:15
PVsyst TRIAL
with v7.4.2
General parameters
Standalone system Standalone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 18 / -90 ° Diffuse Perez, Meteonorm
Circumsolar separate
User's needs
Daily household consumers
Constant over the year
Average 262 kWh/Day
PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 330 Wp
PV Array Characteristics
Generic
AE 330MB-60
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
ULTRA 175 48V 1120Ah
Lithium-ion, LFP
2 in parallel x 5 in series
Number of PV modules 210 units Discharging min. SOC 10.0 %
Nominal (STC) 69.3 kWp Stored energy 483.8 kWh
Modules 21 Strings x 10 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 240 V
Pmpp 62.9 kWp Nominal Capacity 2240 Ah (C10)
U mpp 305 V Temperature Fixed 20 °C
I mpp 206 A
PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.
97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35
Total PV power
Nominal (STC) 69 kWp
Total 210 modules
Module area 348 m²
Cell area 318 m²
Array losses
PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)
-0.8 %
DC wiring losses
Global array res.
Loss Fraction
2.0 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction
0.2 %
PVsyst TRIAL
19/09/23 PVsyst Evaluation mode Page 3/7
Project: Colegio en Cotagaita
Variant: Nueva variante de simulación
PVsyst V7.4.2
VC0, Simulation date:
19/09/23 21:15
PVsyst TRIAL
with v7.4.2
PVsyst TRIAL
radio 2 50 tot 8.0 800
Total daily energy 261870
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
19/09/23 PVsyst Evaluation mode Page 4/7
Project: Colegio en Cotagaita
Variant: Nueva variante de simulación
PVsyst V7.4.2
VC0, Simulation date:
19/09/23 21:15
PVsyst TRIAL
with v7.4.2
Main results
System Production
Useful energy from solar 95583 kWh/year Perf. Ratio PR 54.29 %
Available solar energy 145796 kWh/year Solar Fraction SF 100.00 %
Excess (unused) 46480 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 96.5 %
Missing Energy 0 kWh/year Static SOW 90.0 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
259.2
215.0
231.6
196.1
GlobEff
kWh/m²
250.6
206.4
222.2
187.6
E_Avail
kWh
14518
11995
13056
11220
EUnused
kWh
5999
4373
4706
2961
E_Miss
kWh
0.000
0.000
0.000
0.000
E_User
kWh
8118
7332
8118
7856
E_Load
kWh
8118
7332
8118
7856
SolFrac
ratio
1.000
1.000
1.000
1.000
May 176.2 169.9 10302 1873 0.000 8118 8118 1.000
June 158.9 149.9 9082 939 0.000 7856 7856 1.000
July 170.7 161.2 9741 1354 0.000 8118 8118 1.000
August 191.9 183.5 10962 2554 0.000 8118 8118 1.000
September 208.5 199.8 11743 3588 0.000 7856 7856 1.000
October 250.4 241.2 13964 5525 0.000 8118 8118 1.000
November 256.0 248.1 14217 6047 0.000 7856 7856 1.000
PVsyst TRIAL
December 266.8 262.1 14996 6561 0.000 8118 8118 1.000
Year 2581.3 2482.5 145796 46480 0.000 95583 95583 1.000
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst TRIAL
19/09/23 PVsyst Evaluation mode Page 5/7
Project: Colegio en Cotagaita
Variant: Nueva variante de simulación
PVsyst V7.4.2
VC0, Simulation date:
19/09/23 21:15
PVsyst TRIAL
with v7.4.2
Loss diagram
2581 kWh/m² Global horizontal irradiation
+0.75%
-2.15%
-1.57%
PV loss due to temperature
PVsyst TRIAL
-4.00% Converter Loss during operation (efficiency)
95583 kWh
Energy supplied to the user
PVsyst TRIAL
19/09/23 PVsyst Evaluation mode Page 6/7
Project: Colegio en Cotagaita
Variant: Nueva variante de simulación
PVsyst V7.4.2
VC0, Simulation date:
19/09/23 21:15
PVsyst TRIAL
with v7.4.2
Predef. graphs
Diagrama entrada/salida diaria
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
19/09/23 PVsyst Evaluation mode Page 7/7