• VL = VF *√3
• VL = 220*√3 = 381.051
• VL = 381.051 volt
• Vab = 381.051 V
• Vac = 381.051 V
• Vbc = 381.051 V
• IR = VL/ R =
• IL = If * √3
VL= 380.93 V
• If = 6.3481 Amp
• IL = 10.995 Amp
• Z(Y) = Z (∆) / 3
• Z(Y) = 60Ω / 3 = 20 Ω
• 2π * 50 *0.12 = 37.699 Ω
• Z = R +j * XL = 20 + j *37.699
Ia = 5.155
Ic = 5.155
= Rac ( 220,-120) =
X = -100
Y = 190.5255888
• = 220+j0 – ( -110+j190.5255888)
• = 330- j 190.5255888
• = pol ( 330,-190.5255888
• = 381.051 [-29.999]
• = 1594.4616 w
• Q = 3* Vf * If * sen (φ)
• = 3005.5510 Var
• S = 3* Vf * If
• = 3 * 220 * 5 .155
• = 3402.3 Va
= Cos (φ) = P / S
= Cos (φ)
= 1594.4616 / 0.4686
= 62.053
= 18.1948
Qc = 2481.8212 / 3
Xc = 1 / 2π * f *C
C = 1 / 2π * f *Xc
C = 1 / 2π * 50 * 58.505
= 54.40 μF
Ic = Qc / Vf
= 827.2737 / 220
= 3.760 Amp
= 2.171 Amp
Toda bobina genera potencia reactiva esto afectando la línea e impidiendo el paso
de la potencia activa . Y los condensadores o capacitores consumen esa corriente
reactiva. Se podría decir que la capacitancia es opuesta a la inductancia . En
consecuencia esto mejora el factor de potencia reduciendo el consumo excesivo
por este fenómeno, mejorando la eficiencia del equipo prolongando su vida útil ,
las lineas de fuerza o conexionado tendran menor temperatura por la baja de
consumo