Ejemplo No. 4: Calcular las armaduras de refuerzo de la sgte figura.

Datos:
*Materiales:
*Sección: b ≔ 0.25 m
Hormigón H21 fck ≔ 21 MPa
h ≔ 0.50 m
Acero B500S fyk ≔ 500 MPa
Es ≔ 200000 MPa
Md ≔ 350 kN ⋅ m
*Recubrimiento mecánico: d1 ≔ 5 cm
d2 ≔ 7 cm

Solución:
1.) Materiales:
fck
Hormigon H21 fck = 21 MPa γc ≔ 1.5 fcd ≔ ―― = 14 MPa
γc
fyk
Acero B500S: fyk = 500 MPa γs ≔ 1.15 fyd ≔ ―― = 434.783 MPa
γs
fyd
Es = 200000 MPa εyd ≔ ―― = 2.174 ⋅ 10 -3
Es

2. Diseño: d ≔ h - d1 = 45 cm αcc ≔ 1

Md Cálculo de parámetros del dominio 3límite


μ ≔ ――― = 0.494 3.5
fcd ⋅ b ⋅ d 2 α3lim ≔ ―――= 0.617 β3lim ≔ 1 - 0.4 ⋅ α3lim = 0.753
3.5 + εyd
μ3lim ≔ 0.8 ⋅ α3lim ⋅ β3lim = 0.372

M3lim ≔ μ3lim ⋅ fcd ⋅ b ⋅ d 2 = 263.458 kN ⋅ m


δM ≔ Md - M3lim = 86.542 kN ⋅ m
Nc ≔ αcc ⋅ fcd ⋅ 0.8 ⋅ ⎛⎝α3lim ⋅ d⎞⎠ ⋅ b = 777.241 kN
d2
Ns2 z2 ≔ d - d2 = 38 cm
0.8 x3lim Nc δM
d Ns2 ≔ ―― = 227.742 kN
h z2

Ns1 Ns1 ≔ Nc + Ns2 = 1004.983 kN


d1
σs1 ≔ fyd = 434.783 MPa
d2
α3lim - ―
d
εs2 ≔ ―――― ⋅ 3.5 = 2.617 > εyd = 2.174
α3lim

σs2 ≔ fyd = 434.783 MPa

Cálculo de armaduras:
Ns1 Ns2
As1 ≔ ―― = 23.115 cm 2 As2 ≔ ―― = 5.238 cm 2
σs1 σs2
Práctica No. 3: Calcular las armaduras de refuerzo de la sgte figura.

Datos:
*Materiales:
*Sección: b ≔ 0.20 m
Hormigón H18 fck ≔ 18 MPa
h ≔ 0.40 m
Acero B420S fyk ≔ 420 MPa
Md ≔ 250 kN ⋅ m
*Recubrimiento mecánico: d1 ≔ 7 cm
d2 ≔ 5 cm