CMO LAT NI SE CoDe

SISTEMA DE ANTENAS

NOKIA NODE-B SITE

Antenna Systems Power Systems

Base Stations

Site
Cellular Transmission Systems Installation Materials

Shelters, Towers, Masts, Poles

For internal use 2 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE

For internal use 3 Nokia Siemens Networks

Presentation / Author / Date

PRODUCTOS DE SISTEMA DE ANTENAS


Antenna

Jumper cable Mast Head Amplifier and BiasT

Connector

Feeder clamps Grounding kit Combiners diplexers

Feeder cable

EMP protector

4 4

For internal use Nokia Auxiliary Product Management v. 1.0 04.2002 / Date Nokia Siemens Networks Presentation / Author

ANTENNA LINE
Instalacin de Antenas TM 3G Antenna:

CS72761.08 (K742212) XPol F 1710-2170M 65deg 18dBi 0-8T CS72761.11 (K742215) XPol F 1710-2170M 65deg 18dBi 0-10T CS72191.14 DT-kit for A, F & Euro panel CS72196 Clamp 50-115mm for A, F & Euro panel

For internal use 5 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Downtilt Electrico Ajustable

Combina las ventajes de poder ajustar el downtilt sin afectar el patron de radiacin de la antena.

Downtilt es ajustado usando un rotary knob en la parte inferiro de la antena.

For internal use 6 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
MHA (Mast Head Amplifier)

Incrementa la cobertura Balancea enlace Rx-Tx Mejora la sensibilidad del sistema Disminuye la potencia de transmisin del equipo movil.
BTS RX sin MHA BTS RX con MHA

For internal use 7 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Nokia Mast Head Amplifier

Antenna

2 MHAs mounted backto-back

Jumper

Mast Head Amplifier

Bias T
Drenaje

For internal use 8 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Beneficios del MHA

Totalmente integrado y probado de acuerdo a los requerimeintos de los sistemas. Compacto y facil de instalar Compensa la perdida por cable y combinadores en el uplink Disminuye la potencia de transmisin del equipo movil. Reduce la interferencia inter-cell e intra-cell
For internal use 9 Nokia Siemens Networks Presentation / Author / Date

2 MHAs instalados backto-back

Diagrama de Bloques del Mast Head Amplifier


ANTENNA

BTS
Internal BIAS TEE

TX FILTER BYPASS PATH

RXin FILTER

RXout FILTER

DC CURRENT

Current Sense, Bypass & Alarm Control Circuit


For internal use 10 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Bias-T

Energiza el MHA atravez de la linea de transmisin. Maneja las alarmas del MHA y del Bias-t
Fwd. power coupler DC block (capacitor) Rvrs. power coupler

BTS port

ANT port

Alarm out DC pwr in

Broadband detectors level comparators alarm-sense logic Lightning protection

RF choke (inductor)

For internal use 11 Nokia Siemens Networks

Presentation / Author / Date

Lightning protection (MHA + BiasT)) BiasT

ANT.

MHA /4
LNA LNA

Jumper Ant. port

Transorber (fast)
Large area quarter wave stub (>25mm2) (for imped.matching)

Gas-tube (spark gap) (high energy)

BTS port Jumper Feeder PTFE tube

BiasT BTS

RF band pass filter DC-Input with large conducting areas For internal use 12 Nokia Siemens Networks DC isolation / Author / Date Presentation and high

/4

ANTENNA LINE
Instalacin del MHA

For internal use 13 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin del MHA Installation con bracket especial

Braket montado en mastil (40-110 mm diameter)

3 MHAs instalados en el mastil

For internal use 14 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Colocando el downtilt y orientando las antenas
Esta ok??

Tomando un punto de referencia

Direccionando la antena
Iaquierda...Dere cha...-10 grados

For internal use 15 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Colocando el downtilt y orientando las antenas
Vertical
OK pongamos lo a -6 grados

REQUIREMENT +/- 0,5


Antenna Tilting Angle
(Mechanical)

For internal use 16 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Eveluacin de las inclinaciones de las antenas

Mejora del funcionamiento de la Red

Triple band 824-960 MHz 1710-1880 MHz 1920Dual band 2170 MHz 824-96 & 17102170MHz Broadband 17102170MHz Single band Tilt 1920electrico 2170MHz Polarizacin ajustable Cruzada Polarizacin Vertical Tilt Mecanico Tilt Electrico

Nokia RealTil t

Eficiencia
For internal use 17 Nokia Siemens Networks Presentation / Author / Date

ANTENNA LINE
Downtilt Mecanico

Antena inclinada fisicamente de tal manera que el lobulo principal se deforma en el piso. La reduccin de la seal en la direccin principal pero no cambia el angulo de apertura de la antena. El planeaminto de la red Se dificulta al alterarse el patron de radiacin.
For internal use 18 Nokia Siemens Networks Presentation / Author / Date

ANTENNA LINE
Downtilt Electico

Antena permanece vertical

La fase de la seal que van a los dipolos varia causando el tilt electrico. El patron de radiacin no se altera Se agura un exacto planeamiento de red
For internal use 19 Nokia Siemens Networks Presentation / Author / Date

ANTENNA LINE
Instalacin Antenna Ajustando el downtilt mecanico (Kathrein) Ajustando el downtilt electrico (Kathrein)

Usar la escala en el kit de downtilt para medir la inclinacin. Confirmar con un medidor de angulo Si la escala no existe usar un medidor de agulo

For internal use 20 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Antenna Line System Item Descripcin

Las antenas pueden ser de polarizacin vertical, cruzada y direccionales u omni-direccionales Los jumpers son cables flex de , y son usados en los extremos de los coaxiales. Estos protegen los conectores ante posibles movimientos bruscos de los coaxiales. Los conectores 7/16 tienen la clasificacin IP68. El kit de tierra asegura que la linea de transmisin tenga proteccin de DC ante posibles descargas. El cable coaxial de RF puede ser de diferentes medidas, ejem. 1/2, 7/8 , 1 5/8, etc, dependiendo de la altura de la torre clamps son de acero y plastico. Son facil de instalar. El diseo de los clamps evita que se puedan ajustar demasiado y daar el cable. Un compacto EMP protg la BTS ante posibles descargas. (opcional)
5 6 7 1 2 3 4

Antenna Line System without MHA


For internal use 21 Nokia Siemens Networks Presentation / Author / Date

ANTENNA LINE

Detail

Detail

Detail

Detail

Detail

Detail

Note:The photo shows the Antenna system at outdoor site in Singapore.

Detail

Detail

Detail

For internal use 22 Nokia Siemens Networks

Presentation / Author / Date

SOLUCION DE INSTALACION DE ANTENA

(X+0+0 X+0+0) 1 SECTOR (X+0+0) X= cantidad de TRX


For internal use 23 Nokia Siemens Networks Presentation / Author / Date

(X+X+0 X+X+0) 2 SECTOR (X+X+0) X= cantidad de TRX

X+X+X) (X+X+X 3 SECTOR (X+X+X) X= cantidad de TRX

ANTENNA LINE
Sencillo

OUTDOO R

INDOOR

EMP

Revisar el rango de frecuencia del material utilizado Se deben usar conectores aprobados Los conectores deben ser los adecuados de acuerdo al tipo de cable (fabricante) Los cables deben estar etiquetados a ambos extremos Se deben emplear adecuadas herramientas para ensamblar los conectores. Todos los cables deben estar ajustados adecuadamente.
For internal use 24 Nokia Siemens Networks Presentation / Author / Date

ANTENNA LINE
Con MHA

OUTDOO R

INDOOR

Bias-T

Revisar el rango de frecuencia del material utilizado Se deben usar conectores aprobados Los conectores deben ser los adecuados de acuerdo al tipo de cable (fabricante) Los cables deben estar etiquetados a ambos extremos Se deben emplear adecuadas herramientas para ensamblar los conectores. Todos los cables deben estar ajustados adecuadamente.
For internal use 25 Nokia Siemens Networks Presentation / Author / Date

ANTENNA LINE
Calculo de la atenuacin del coaxial Atenuacin en Jumper cable 0.68dB (2 jumpers con 4 conectores) Atenuacin en conector de antena ( 2 conectores ) 0.10 dB Atenuacin en EMP dB Atenaucin en coaxial

0.10
RF 7/8 5.53 dB 100m RF 1 5/8 3.36 dB 100m

Ejemplo: Se tiene un recorido de 36 m. La atenuacin limite es Que cable se deb usar? 0.1 + 0.1 + 0.68 + 36m X 0.0553 = 3 dB -> 7/8" feeder cable 3 dB.

For internal use 26 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Atenuacin en Coaxiales CABLE RFF 3/8-50 RFF 1/2-50 RF 1/2-50 7/8 RF 7/8-50 !! RF 1 1/4-50 5/8 RF 1 5/8-50 !! FREQUENCIA 900 MHz 13.9 dB/100m 10.6 dB/100m 6.88 dB/100m 3.53 dB/100m 2.74 dB/100m 2.11 dB/100m FREQUENCIA 1800 MHz 20.5 dB/100m 15.6 dB/100m 10.1 dB/100m 5.04 dB/100m 4.12 dB/100m 3.05 dB/100m FREQUENCIA 2000 MHz 21.8 dB/100m 16.7 dB/100m 10.7 dB/100m 5.53 dB/100m AVA 4.39 dB/100m 3.36 dB/100m AVA

NOTE: Given values are for NK Cables feeder cables except 7/8 and 15/8 are for Andrew AVA cable type, other manufacturers may have different values, check the proper values before implementation from manufacturers data sheets
For internal use 27 Nokia Siemens Networks Presentation / Author / Date

ANTENNA LINE
Intrucciones de instalacin de antenas.

1. 2.

Verificar que el soporte de antena este colocado en la posicin correcta. Izar la antena hasta el soporte Nota: Prevenir los problemas que se puedan encontrar debido a condiciones climaticas para evitar que la antena sufra daos.

3. 4. 5.

Instalar la antena totalmente vertical o con la inclinacin indicada por planning. Usar las especificaiones de la antena para tener en cuanta la separacin vertical y horizontal con otras antenas. Conectar el Jumper en la antena, el otro extremo quedara desconectado momentaneamente Nota: proteger el conector libre con cinta. Colocar clamps en el jumper hacia la antena

6.

For internal use 28 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Curvatura de cables

La curvatura de los cables deben seguir las escificaciones deNSN para evitar daos y aumentar la perdida en el cable. No permitido:
MAL MAL

For internal use 29 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Curvatura de cables

CABLE RFF 3/8-50 RFF 1/2-50 RF 1/2-50 RF 7/8-50 RF 1 1/4-50 RF 1 5/8-50

CURVATURA MINIMA PARA UNA SOLA CURVA 13 mm 15 mm 80 mm 120 mm 200 mm 250 mm

CURVATURA MINIMA PARA VARIAS CURVAS 25 mm 30 mm 160 mm 250 mm 350 mm 500 mm

NOTE: Given values are for NK Cables feeder cables, other manufacturers may have different values, check the proper values before implementation from manufacturers data sheets
For internal use 30 Nokia Siemens Networks Presentation / Author / Date

ANTENNA LINE
Curvatura de cables
FEEDER TYPE REPEATED REPEATED BENDING RADIUS SINGLE BENDING RADIUS

RF 1 5/8

500mm

250mm

RF 1 1/4 RF 7/8 RF 1/2 RFF 1/2 RFF 3/8

350mm 250mm 160mm 30m m 25m m

200mm 120mm 80mm

For internal use 31 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Distancia entre clamps

Seguir las especificaciones de los cables. Cable Distancia entre clamps Optima 1/4 Superflex 3/8 Superflex 1/2 Superflex 1 /2 Feeder 7/8 Feeder 1-5/8 Feeder 150mm 150mm 250mm 500mm 900mm 1000mm Maxima 200mm 200mm 300mm 600mm 1000mm 1400mm

NOTE: Given values are for NK Cables feeder cables, other manufacturers may have cturers manufacturers manufacturer different values, check the proper values before implementation from manufacturers data sheets
For internal use 32 Nokia Siemens Networks Presentation / Author / Date

ANTENNA LINE
Distancia entre clamps

Seguir las especificaciones de los cables.


RF 1/4 superflex RF 3/8 superflex RFF 1/2 superflex RF 1/2 150mm 150mm 250mm 200mm (Max) 200mm (Max) 300mm (Max)

500mm

600mm (Max)

RF 7/8

900mm

1000mm (Max)

RF 1 5/8

1000mm

1400mm (Max)

For internal use 33 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin de coaxial y jumper

Detail

Detail

Detail

Detail

Detail

Detail

Detail

Detail

Detail

For internal use 34 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin de cables coaxiales

Tener cuidado con:


Minimo radio de curvatura Maxima fuerza al jalar los cables Manejo del carrete de en el que viene el cable Correcto manejo de las herramientas

For internal use 35 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Herramientas y conectorizacin

Usar guantes! Revisar el estado de las herramientas Revisar los conectores y su proteccin contra el agua protecci Revisar las instrucciones de instalacin: medicin correcta instalaci para cortar, etc. Usar las herramientas con cuidado, no ajustar demasiado cortar. antes de cortar. Usar el torque correcto en todas las conexiones.

For internal use 36 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin de cables coaxiales

CRITICO: Tener cuidado al izar los cables, se podria daar la proteccin del cable EVITAR: Izar el cable con fuerzas desiguales. USAR: Izamiento con cuidado. TENER CUIDADO CON: Superficies que puedan daar el cables, curvaturas excesivas, etc

For internal use 37 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Tipo de cable por ditancia

0 m < L < 8 m -RF 1/2" 9 m < L < 35 m 36 m < L < 50 m L > 50m adicionar MHA 5/8" -RF 7/8" -RF 1-5/8" RF 1-

Este ejemplo puede variar dependiendo del proyecto.!

For internal use 38 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin de clamps

Tener cuidado con superficies con filo ! Clamps AJUSTADOS AL MAXIMO pueden afectar el cable y originar perdidas en el. Tengan cuidado en NO PERDER los anillos de plastico Los cables debern tener como terminacin una impedancia de carga (o fuente) resistiva igual a una impedancia caracteristica, generalmente 50 .

For internal use 39 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin del jumper
Correcta curvatura Incorrecta curvatura

El jumper es fijado Con clamps

sueltos, fijaci Cables sueltos, sin fijacin

OK
For internal use 40 Nokia Siemens Networks Presentation / Author / Date

NOK :

ANTENNA LINE
Instalacin de jumper La distancia de clamps en un jumper es de 500mm Para un jumper de 1.5m , se deben colocar minimo 2 clamps y para un clamps. jumper de 3m , se deben colocar minimo 4 clamps

Jumper de 1.5m minimo) 2 clamps ( minimo)

For internal use 41 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin de jumper

Los jumpers se deben instalar los mas rectos posible Evitar curvas adicionales. Se deben usar las herramientas adecuadas. Los cables deben ser fijados apropiadamente. De preferencia se deben usar cables prefabricados.

For internal use 42 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Conexin de jumpers

Usar las herramientas correctas La conexin de los jumpers deben tener el torque correcto Conector 7/16 ---- 25Nm

For internal use 43 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Prueba de laboratorio en cables flojos

flojos: Efectos de cables flojos: Tambien los conectores 7/16 son sensibles a los torques correctos. Cuando se afloja un conector, al principio se tendran problemas de intermodulacin, luego se perderan valores de retorno. Facilmete se pueden tener perdidas de 6...12dB en los valores de retorno, cuando un conector es ajustado muy suave ( 5...10Nm). Casi toda la potencia pasara atravez del cable, pero se tendran alarmas de VSWR y la perdida por insersin puede llegar a aumentar en 1..2dB.

For internal use 44 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin de jumpers

OK

NOK

OK
Jumpe r Jumpe r

NOK

For internal use 45 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin de jumpers

O K

NOK

OK

OK
Jumper Jumper

NOK

For internal use 46 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Vulcanizado de conectores

Almecenar cables bajo techo Revisar los extremos de los cables Proteger el extremo del cable despues de cortarlo; de preferencia con cinta vulcanizante Kits de tierra: Sellado IP 67. Terminal del cable de tierra de ser revisado. Revisar que este bien ajustado.

For internal use 47 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin del jumper en BTS

For internal use 48 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Instalacin del jumper en BTS

Shorter jumper

Longer jumper

For internal use 49 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Kits de tierra

Detail

Detail

Detail

Detail

Detail

Detail

Note:The photo shows the Ground system at outdoor site in Singapore.

Detail

Detail

Detail

For internal use 50 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Kits de tierra

EMP para cada EMP linea es opcional Si se usa MHA , solo se usaran kits de tierra Si el tramo vertical es mayor a 40m , se necesita un kit de tierra en la parte central Kit de tierra

Barra de tierra
For internal use 51 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Kits de tierra El kit de tierra siempre se deb ubicar en el tramo recto del cable, nunca en una curva.

Instalacin Aceptable

For internal use 52 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Cableado de kits de tierra

EMP GROUNDING BUSBAR

Los EMP o kits de tierra deben ser conectado a una barra de tierra Los cables coaxiales deben tner un kit de tierra antes del pasamuro. Se deben usar las herramientas adecuadas al instalar los kits de tierra Los cables deben ser fijados correctamente

FEEDER ENTRY GROUNDING BUSBAR

For internal use 53 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Cableado de kits de tierra

Los EMP o kits de tierra deben ser conectado a una barra de tierra Los cables coaxiales deben tner un kit de tierra antes del pasamuro. Se deben usar las herramientas adecuadas al instalar los kits de tierra Los cables deben ser fijados correctamente

FEEDER GROUNDING BUSBAR

For internal use 54 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Cableado de kits de tierra

Los EMP o kits de tierra deben ser conectado a una barra de tierra Los cables coaxiales deben tner un kit de tierra antes del pasamuro. Se deben usar las herramientas adecuadas al instalar los kits de tierra Los cables deben ser fijados correctamente

FEEDER GROUNDING BUSBAR

For internal use 55 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Conexin a tierra de los EMP

A antena

Barra de tierra aislada

EMP

Jumper a BTS

Cable de tierra de EMP

aislador

Hacia la tierra principal

For internal use 56 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Conexin a tierra de los kits de tierra
A antena

Barra de tierra aislada A BTS

Cable de tierra del kit de tierra

aislador

A tierra principal

For internal use 57 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Posicin de los conectores

El conector no debe tocar la escalerilla. De no ser posible , aislar la escalerilla con cinta aislante.

For internal use 58 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Weather Proofing

Todas las conexiones de los cables coaxiales que esten a la intemperie, deben ser vulcanizados y encintados. Conexiones a encintar: Coaxial con jumper Coaxial con antena y MHA Coaxial con EMP y combinador (en el caso que este a la intemperie) Los kits de tierra de ber ser sellados de acuerdo a las especificaciones. Los pasamuros deben estar correctamente sellados. Asegurar que los torques en las conexiones sean las correctas antes de encintar!

encintados

For internal use 59 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Conexin Feeder con jumper

1. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA. 2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA 3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA
20 50 50 20

1. UNA CAPA DE CINTA AISLANTE

2. DOS CAPAS DE CINTA VULACANIZNATE

3. TRES CAPAS DE CINTA AISLANTE

For internal use 60 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Feeder to Antenna, Combiner or MHA connection

1. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA. 2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA 3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA
TIE WRAP
50 20

1. UNA CAPA DE CINTA AISLANTE 2. DOS CAPAS DE CINTA VULACANIZNATE 1. TRES CAPAS DE CINTA AISLANTE
For internal use 61 Nokia Siemens Networks Presentation / Author / Date

ANTENNA LINE
Feeder to EMP connection

1. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA. 2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA 3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA
20 50

TIE WRAP

50

20

1. UNA CAPA DE CINTA AISLANTE 2. DOS CAPAS DE CINTA VULACANIZNATE 1. TRES CAPAS DE CINTA AISLANTE

For internal use 62 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Feeder to Grounding kit connection

2. CONEXION DEBE SER ENCINTADA USANDO CINTA VULCANIZANTE HOMOLOGADA 3. CONEXION DEBE SER ENCINTADA USANDO CINTA AISLANTE HOMOLOGADA * Usar este metodo si los kits de tierra no vienen con cintas o sin instrucciones
20 50 100 20

2. DOS CAPAS DE CINTA VULACANIZNATE

1. TRES CAPAS DE CINTA AISLANTE

For internal use 63 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Pasamuros

Usar sellos apropiados. Sellar la entrada de cables apropiadamente.

NOK

For internal use 64 Nokia Siemens Networks

Presentation / Author / Date

ANTENNA LINE
Comisionamiento

Seguir las intrucciones dadas para las mediciones. Colocar las mediciones en el Site Folder. Imprimir las graficas en papel A4 y adjuntar al Site Folder. Tres graficas por pagina Adjuntar los archivos en formato electronico
ANTENNA LINE

RETURN LOSS

RETURN LOSS